+ All Categories
Home > Documents > Cables & Accessories

Cables & Accessories

Date post: 17-Oct-2015
Category:
Upload: touta-med
View: 23 times
Download: 0 times
Share this document with a friend

of 38

Transcript
  • 5/27/2018 Cables & Accessories

    1/38

  • 5/27/2018 Cables & Accessories

    2/382

    ABOUT US

    Being a subsidiary of a leading Group worldwide means to benet from its noto-riety and its power; It means to emphasize its regional and cultural characteristics

    as well as its own competences and its exibility; It also means to be conscious ofour responsibility toward future generations and bring our own contribution howe-

    ver modest it may be, to the durable development of our planet.

    As the French subsidiary of KATHREIN Group, it is our responsibility and our prio-

    rity to always serve and develop the best Telecom solutions that match the needsof the different actors within the mobile market.

    Being totally aware of the fast evolutions and the growing needs of the Middle-

    East and African mobile market, KATHREIN France now offers complete aerial

    solutions to mobile operators and installation companies.

    Our know-how, our export-related experience, our technical support, as well asour ability to react immediately are the key assets which all together make us able

    to answer, as perfectly as possible, your needs. We are also able to be at your side

    for your network and all your projects of sites roll-out, extension or optimization.

    Apart from Base Station Antennas for Mobile Networks, KATHREIN FRANCE also

    supplies RF equipment (feeder cables, coaxial connectors and jumpers), RF ac-cessories (for aerials, clamps for feeder cables, cable trays, tools etc..), RF protec-tions against lightning, as well as solutions for weatherproong and isolation.KATHREIN FRANCE Export Team hopes that this new brochure Cables, Connec-tors and RF Accessories 2011 will bring you whole satisfaction.

  • 5/27/2018 Cables & Accessories

    3/38 3

    Quality & Environmental certicates

  • 5/27/2018 Cables & Accessories

    4/38

    PRODUCTS REFERENCES

    Description References pages

    FEEDERS

    FEEDER 1/2 HIFLEX CFC05019 p 8

    FEEDER 1/2 RIGID CFC05004 p 9

    NEW FEDEER 7/8 ULTRA LOW LOSS CFC05041 p 10

    NEW FEEDER 1-1/4 ULTRA LOW LOSS CFC05040 p 11

    NEW FEEDER 1- 5/8 ULTRA LOW LOSS CFC05034 p 12

    CONNECTORS COAX.

    7/16 MALE RIGHT 1/2 FLEXIBLE CRA05692 p 13

    7/16 FEMALE RIGHT 1/2 FLEXIBLE CRA05082 p 13

    7/16 MALE RIGHT ANGLE 1/2 FLEXIBLE CRA05206 p 13

    7/16 MALE 1/2 RIGID CRA05982 p 13

    7/16 FEMALE RIGHT 1/2 RIGID CRA05706 p 13

    7/16 MALE RIGHT ANGLE 1/2 RIGID CRA05216 p 13

    7/16 MALE RIGHT 7/8 RIGID CRA05717 p 13

    7/16 FEMALE RIGTH 7/8 RIGID CRA05718 p 13

    7/16 MALE RIGHT 7/8 CRA05720 p 13

    7/16 FEMALE RIGHT 7/8 CRA05721 p 13

    7/16 FEMALE RIGHT 1- 1/4 CRA05719 p 13

    7/16 MALE RIGHT 1- 5/8 CRA05287 p 13

    7/16 FEMALE RIGHT 1- 5/8 CRA05286 p 13

    JUMPERS

    7/16 MALE RIGHT/MALE RIGHT 0,50m HIFLEX 961 005 p 14

    7/16 MALE RIGHT/MALE RIGHT 1m HIFLEX 961 010 p 14

    7/16 MALE RIGHT/MALE RIGHT 1,5m HIFLEX 961 015 p 14

    7/16 MALE RIGHT/MALE RIGHT 2m HIFLEX 961 020 p 14

    7/16 MALE RIGHT/MALE RIGHT 2,5m HIFLEX 961 025 p 14

    7/16 MALE RIGHT/MALE RIGHT 3m HIFLEX 961 030 p 14

    7/16 MALE RIGHT/MALE RIGHT 4m HIFLEX 961 040 p 14

    7/16 MALE RIGHT/MALE RIGHT 5m HIFLEX 961 050 p 14

    7/16 MALE RIGHT/MALE RIGHT ANGLE 0,50m HIFLEX 961 505 p 14

    7/16 MALE RIGHT/MALE RIGHT ANGLE 1m HIFLEX 961 510 p 14

    7/16 MALE RIGHT/MALE RIGHT ANGLE 1,50m HIFLEX 961 515 p 14

    7/16 MALE RIGHT/MALE RIGHT ANGLE 2m HIFLEX 961 520 p 14

    7/16 MALE RIGHT/MALE RIGHT ANGLE 2,50m HIFLEX 961 525 p 14

    7/16 MALE RIGHT/MALE RIGHT ANGLE 3m HIFLEX 961 530 p 14

    7/16 MALE RIGHT/MALE RIGHT ANGLE 4m HIFLEX 961 540 p 14

    7/16 MALE RIGHT/MALE RIGHT ANGLE 5m HIFLEX 961 550 p 14

    7/16 MALE RIGHT/MALE RIGHT 0,50m RIGID 962 005 p 15

    7/16 MALE RIGHT/MALE RIGHT 1m RIGID 962 010 p 15

    7/16 MALE RIGHT/MALE RIGHT 1,5m RIGID 962 015 p 15

    7/16 MALE RIGHT/ MALE RIGHT 2m RIGID 962 020 p 15

    7/16 MALE RIGHT/MALE RIGHT 2,5m RIGID 962 025 p 15

    7/16 MALE RIGHT/MALE RIGHT 3m RIGID 962 030 p 15

    7/16 MALE RIGHT/MALE RIGHT 4m RIGID 962 040 p 15

    7/16 MALE RIGHT/MALE RIGHT 5m RIGID 962 050 p 15

    CABLE PREPARATION TOOL

    1/2 FLEXIBLE 960 085 p 19

    1/2 RIGID 960 084 p 19

    7/8 960 064 p 19

    1- 1/4 960 123 p 19

    1- 5/8 960 086 p 19

    Description References pages

    WRENCH HANDLES FOR CONNECTORS

    1/2 950 002 p 20

    7/8 950 003 p 20

    1- 1/4 950 004 p 20

    1- 5/8 950 001 p 20

    CLAMPS FOR FEEDERS

    CLIP FOR FEEDER 1/2 ON PYLON A CORNIERE 960 053 p 24

    CLIP FOR FEEDER 1- 1/4 ON PYLON A CORNIERE 960 088 p 24

    CLIP FOR FEEDER 1- 5/8 ON PYLON A CORNIERE 960 087 p 24

    1 FEEDER 1/2 HANGING ON FLAT AND ROUND CAC05300 p 25

    1 FEEDER 7/8 HANGING ON FLAT ET ROUND CAC05301 p 25

    1 FEEDER 1- 5/8 HANGING ON FLAT AND ROUNDREF TO ASK

    FOR

    1 FEEDER 1- 1/4 HANGING ON FLAT AND ROUNDREF TO ASK

    FOR

    2 FEEDERS 1/2 HANGING ON FLAT AND ROUNDREF TO ASK

    FOR

    2 FEEDERS 7/8 HANGING ON FLAT AND ROUND CAC05302 p 25

    2 FEEDERS 1- 5/8 HANGING ON FLAT AND ROUND CAC05303 p 25

    2 FEEDERS 1- 1 /4 HANGING ON FLAT AND ROUNDREF TO ASK

    FOR

    3 FEEDERS 1/2 HANGING ON FLAT AND ROUNDREF TO ASK

    FOR

    3 FEEDERS 7/8 HANGING ON FLAT AND ROUND CAC05304 p 25

    3 FEEDERS 1- 5 /8 HANGING ON FLAT ET ROUNDREF TO ASK

    FOR

    3 FEEDERS 1- 1/4 HANGING ON FLAT AND ROUND CAC05315 p 25

    6 FEEDERS COAX. 7/8 CAC05311 p 25

    HOISTING GRIPS

    PRE LACED FOR 1/2 950 010 p 18

    PRE LACED FOR 7/8 950 011 p 18

    PRE LACED FOR 1- 5/8 950 012 p 18

    PRE LACED FOR 1- 1/4REF TO ASK

    FOR

    WEATHERPROOFING

    JUMPERS/ANTENNAS & FEEDERS/JUMPERS CAC05347 p 22

    1/2 JUMPER TO 7/8 FEEDER CAC05348 p 22

    1/2 JUMPER TO 1- 1/4 FEEDER CAC05350 p 22

    1/2 JUMPER TO 1- 5/8 FEEDER CAC05351 p 22

    KITS DETANCHEITE

    RUBAN BUTYL (0,50 m x 28 mm) & PLASTIC ELECTRICAL

    SCOTCH (10 m x 15 mm)CAC05346 p 23

    COLLAR COLSON

    NON LOOSENING BLACK THROUGH JOINT 357 x 9

    100 PIECES BOX IN POLYAMID 12CAC05185 p 26

    UNIVERSAL EARTHING KIT

    UNIVERSAL FOR FEEDER COAX 1/2 TO 7/8 921 060 p 31

    SPECIFICALLY FOR FEEDER 7/8 921 061 p 32

    SPECIFICALLY FOR FEEDER 1- 5/8 921 020 p 32

    SPECIFICALLY FOR FEEDER 1- 1/4 921 062 p 32

    BTS PROTECTION

    EMP PROTECTION 900/1800/UMTS CRA05255 p 33

    GROUNDING BAR

    GROUNDING BAR STAINLESS STEEL AISI 3004 (V2A) OU

    CUIVRE 9 X M8960 054 p 30

    ROAD OF CHAINAGE

    FULL KIT : LIGHTNING ARRESTER, FLOW AND CROWS-

    FOOT CONNECTOR

    REF TO ASK

    FORp 37

    HOLE ENTRIES

    MODULE 6x2 7/8 + STUFFING CAC p 27

    4

  • 5/27/2018 Cables & Accessories

    5/38 5

    TABLE OF CONTENTS

    IINDEX : Product References Page 04

    TABLE OF CONTENTS Page 05

    First Part : RF Equipment Page 06/07Hiex Feeder cable 1/2 Page 08Rigid Feeder Cable 1/2 Page 09

    Feeder cable 7/8 Ultra-Low Losses Page 10Feeder cable 1-1/4 Ultra-Low Losses Page 11Feeder cable 1-5/8 Ultra-Low Losses Page 12Coaxial Connectors Page 13Hiex Jumpers Page 14Rigid Jumpers Page 15

    Second Part : RF Accessories Page 16/17

    Hoisting Grips Page 18Stripping Tools Page 19Wrench Handles for Connectors Page 20Instructions to use Stripping Tools Page 21Protection of connections Page 22Weatherproong Kit Page 23Snap-in Hangers for Feeder Cables from 1/2 to 5/8 Page 24Self-Locking Cable Clamps for 1, 2, 3, 4 and 6 Feeder Cables Page 25Cables Ties Page 26Wall Entries Page 27

    Third Part : Protection of RF Equipment Page 28/29

    Copper Grounding Bar Page 30

    Universal Earthing Kit Page 31Earthing Kits for 1/2, 7/8, 1-1/4 and 5/8 Feeder Cables Page 32Lightning Arrester for GSM 900, 1800, and UMTS Page 33Lightning Arrester : Installation Instructions Page 34Basic Information for a safe Cell Site Page 35Protection of equipment upper extremities Page 36

    Cell Sites suffering from Lightning : How to provide a safe owpath for the lightning current Page 37

  • 5/27/2018 Cables & Accessories

    6/38

    Rfrences:

    6

    The deployment of base stations requires feeder cables and coaxial connectors of high qualityto reduce insertion losses as much as possible, to get the best signal transmission.

    KATHREIN FRANCE feeder cables are designed to provide you the best electrical results anda higher longevity than other similar cables offered on the market. It is actually the best choicefor GSM, UMTS and other wireless applications that demand very low insertion losses and theguarantee of a high longevity.

    Globally speaking, Insertion losses are typically of 30dB ; but we guarantee the lowest loss,meaning 23dB in GSM frequencies, when our connectors are used with both ends of feedercables. Consequently, the mitigation measures are the best we can have on the market.The rst part will provide you with a great view of our RF equipment (feeder cables, coaxialconnectors, and jumpers) that we offer.

    RF

  • 5/27/2018 Cables & Accessories

    7/38 7

    Rfrences:

    TABLE OF CONTENTS

    First Part : RF Equipment Pages 06/07

    Hiex Feeder cable 1/2 Page 08Rigid Feeder Cable 1/2 Page 09Feeder cable 7/8 Ultra-Low Losses Page 10Feeder cable 1-1/4 Ultra-Low Losses Page 11Feeder cable 1-5/8 Ultra-Low Losses Page 12Coaxial Connectors Page 13Hiex Jumpers Page 14Rigid Jumpers Page 15

    EQUIPMENT

  • 5/27/2018 Cables & Accessories

    8/38

    FEEDER CABLE 1/2 HIFLEX

    8

    CFC 05019 1/2 hiex

    Cable with standard UV resistant PE jacket, halogen free

    according to IEC 60754

    SPECIFICATIONS

    Design

    Inner conductor

    Material copper clad aluminium wire

    Diameter (mm) 3.55

    DielectricMaterial gas-injected cellular polyethylene

    Diameter (mm) 9.0Outer conductor

    Material corrugated copper tube

    Diameter (mm) 12.2JacketMaterial black polyethylene

    Thickness (mm) 0.65Diameter (mm) 13.5

    Mechanical specicationsMinimum bending radiussingle bending (cm) 315 repeated bends (cm) 4Maximum pulling strength (daN) 70Recommended temperature rangeStorage -70 to +85CInstallation -40 to +60COperation -55 to +85CMaximum length per hoisting grip (m) 70Maximum hanger spacing 0.5Flat plate crush resistance (kg/mm) 1.7Bending moment (Nm) 2.7

    Weight (kg/km) 200

    (*) nominal values(**) Ambient temperature = 40C; Temperature of inner

    conductor = 100C;

    Electrical specicationCharacteristic impedance () 50 1Nominal capacity (pF/m) 82Relative propagation velocity (%) 82Inductance (H/m) 0.200DC-resistance at 20Cinner conductor (/km) 2.65outer conductor (/km) 3.0RF peak voltage (kV) 1.13

    RF peak power (kW) 12.8Cut-off-frequency (GHz) 13.2Insulation resistance (M.km) >>5000

    Attenuation [1] and power ratingFrequency

    (MHz)Attenuation at 20C(*)(dB/100m)

    Mean power

    rating(**) (kW)10 0.96 9.9020 1.37 6.9630 1.68 5.6680 2.79 3.42100 3.13 3.04

    150 3.88 2.46200 4.51 2.11300 5.60 1.70400 6.53 1.46450 6.96 1.37500 7.38 1.29600 8.15 1.17700 8.87 1.07800 9.55 1.00894 10.16 0.94960 10.57 0.901000 10.82 0.881500 13.62 0.70

    1700 14.63 0.651800 15.12 0.631880 15.51 0.612000 16.08 0.592170 16.86 0.572200 17.00 0.562300 17.45 0.552400 17.89 0.532500 18.33 0.523000 20.42 0.474000 24.29 0.396000 31.21 0.31Reference :

  • 5/27/2018 Cables & Accessories

    9/38

    FEEDER CABLE 1/2 RIGID

    9

    CFC 05004 1/2 rigid

    Cable with standard UV resistant PE jacket, halogen free

    according to IEC 60754

    SPECIFICATIONS

    DesignInner conductorMaterial copper clad aluminium wireDiameter (mm) 4.8DielectricMaterial gas-injected cellular polyethyleneDiameter (mm) 12.4Outer conductorMaterial corrugated copper tubeDiameter (mm) 13.7JacketMaterial black polyethyleneThickness (mm) 1.1Diameter (mm) 16.0

    Mechanical specicationsMinimum bending radius

    single bending (cm) 715 repeated bends (cm) 12.5Maximum pulling strength (daN) 100Recommended temperature rangeStorage -70 to +85CInstallation -40 to +60COperation -55 to +85CMaximum length per hoisting grip (m) 70Maximum hanger spacing 1Flat plate crush resistance (kg/mm) 1.9Bending moment (Nm) 3.5Weight (kg/km) 235

    [1] a = 0.2105b = 0.000625x () = a . f + b . f [dB/100m](*) nominal values(**) Ambient temperature = 40C; Temperature of innerconductor = 100C;VSWR = 1.0; no solar loading

    Cable with UV resistant, halogen free, low smoke, ameretardant jacket according to IEC 60754-2, IEC 60332-1-

    2, IEC 60332-3 Cat. C and IEC 61034-1+2

    Electrical specicationsCharacteristic impedance () 50 1Nominal capacity (pF/m) 76Relative propagation velocity (%) 88Inductance (H/m) 0.190

    DC-resistance at 20Cinner conductor (/km) 1.48outer conductor (/km) 2.04RF peak voltage (kV) 1.6RF peak power (kW) 25.6Cut-off-frequency (GHz) 9.8Insulation resistance (M.km) >>5000

    Attenuation [1] and power ratingFrequency

    (MHz)Attenuation at 20C(*)(dB/100m)

    Mean power

    rating(**) (kW)10 0.67 11.74

    20 0.95 8.2730 1.17 6.7380 1.93 4.08100 2.17 3.64150 2.67 2.95200 3.10 2.54300 3.83 2.06400 4.46 1.77450 4.75 1.66500 5.02 1.57600 5.53 1.43700 6.01 1.31800 6.45 1.22

    894 6.85 1.15960 7.12 1.111000 7.28 1.081500 9.09 0.871700 9.74 0.811800 10.06 0.781880 10.30 0.772000 10.66 0.742170 11.16 0.712200 11.25 0.702300 11.53 0.682400 11.81 0.672500 12.09 0.65

    3000 13.40 0.594000 15.81 0.506000 20.06 0.39

    Reference :

  • 5/27/2018 Cables & Accessories

    10/38

    FEEDER CABLE 7/8

    10

    CFC 05041 Feeder cable 7/8

    Electrical specicationsCharacteristic impedance () 50 1Nominal capacity (pF/m) 75Relative propagation velocity (%) 89Inductance (H/m) 0.187DC-resistance at 20Cinner conductor (/km) 1.34outer conductor (/km) 1.0RF peak voltage (kV) 2.9

    RF peak power (kW) 86Cut-off-frequency (GHz) 5.1Insulation resistance (M .km) >>5000

    Attenuation [1] and power ratingFrequency

    (MHz)Attenuation at 20C(*)(dB/100m)

    Mean power rating(**)(kW)

    10 0.35 25.4620 0.50 17.9330 0.62 14.6080 1.02 8.85100 1.14 7.89150 1.41 6.40

    200 1.63 5.51300 2.02 4.46400 2.35 3.83450 2.50 3.60500 2.64 3.41600 2.91 3.09700 3.16 2.85800 3.40 2.65894 3.61 2.49960 3.75 2.401000 3.83 2.351500 4.79 1.88

    1700 5.13 1.751800 5.30 1.701880 5.43 1.662000 5.62 1.602170 5.88 1.532200 5.92 1.522300 6.07 1.482400 6.22 1.452500 6.37 1.413000 7.06 1.274000 8.33 1.086000 - -

    STANDARD

    Cable with standard UV resistant PE jacket,

    halogen free according to IEC 60754

    SPECIFICATIONS

    DesignInner conductorMaterial smooth copper tubeDiameter (mm) 9.3

    DielectricMaterial

    gas-injected cellular poly-

    ethyleneDiameter (mm) 23.5Outer conductorMaterial corrugated copper tubeDiameter (mm) 25.0JacketMaterial black polyethyleneThickness (mm) 1.4Diameter (mm) 28.0

    Mechanical specicationsMinimum bending radiussingle bending (cm) 1015 repeated bends (cm) 25Maximum pulling strength (daN) 150Recommended temperature

    range

    Storage -70 to +85CInstallation -40 to +60COperation -55 to +85CMaximum length per hoistinggrip (m)

    70

    Maximum hanger spacing 1.2

    Flat Plate Crush resistance(kg/mm) 1.4 Bendingmoment (Nm)Bending moment (Nm) 11.6Weight (kg/km) 496

    [1] a = 0.1107b = 0.000333x () = a . f + b . f [dB/100m](*) nominal values(**) Ambient temperature = 40C; Temperature of innerconductor = 100C;VSWR = 1.0; no solar loading

    Reference :

  • 5/27/2018 Cables & Accessories

    11/38

    FEEDER CABLE 1- 1/4

    11

    CFC 05040 Feeder cable 1- 1/4

    STANDARDCable with standard UV resistant PE jacket, halogen

    free according to IEC 60754

    SPECIFICATIONS

    DesignInner conductorMaterial corrugated copper tubeDiameter (mm) 13.6Dielectric

    Material gas-injected cellular poly-ethyleneDiameter (mm) 33.5Outer conductorMaterial corrugated copper tubeDiameter (mm) 36.0JacketMaterial black polyethyleneThickness (mm) 1.5Diameter (mm) 39.0

    Mechanical specicationsMinimum bending radius

    single bending (cm) 2015 repeated bends (cm) 30Maximum pulling strength (daN) 200Recommended temperature range- Storage -70 to +85C- Installation -40 to +60C- Operation -55 to +85CMaximum length per hoisting grip(m)

    70

    Maximum hanger spacing 1.4Flat plate crush resistance (kg/mm) 3.4Bending moment (Nm) 25Weight (kg/km) 830

    [1] a = 0.084b = 0.000461x() = a . f + b . f [dB/100m](*) nominal values(**) Ambient temperature = 40C; Temperature ofinner conductor = 100C;VSWR = 1.0; no solar loading

    Electrical specicationsCharacteristic impedance () 50 1Nominal capacity (pF/m) 76

    Relative propagation velocity (%) 88

    Inductance (H/m) 0.190DC-resistance at 20C- inner conductor (/km) 1.8- outer conductor (/km) 0.5RF peak voltage (kV) 4.25RF peak power (kW) 180

    Cut-off-frequency (GHz) 3.3Insulation resistance (M.km) >>5000

    Attenuation [1] and power rating

    Frequency

    (MHz)Attenuation at 20C(*)(dB/100m)

    Mean power ra-

    ting(**) (kW)

    10 0.27 39.73

    20 0.38 27.9030 0.47 22.66

    80 0.79 13.62100 0.89 12.12150 1.10 9.78

    200 1.28 8.39300 1.59 6.74

    400 1.86 5.76450 1.99 5.40

    500 2.11 5.09

    600 2.33 4.60

    700 2.55 4.22

    800 2.74 3.91894 2.92 3.67960 3.05 3.53

    1000 3.12 3.44

    1500 3.94 2.72

    1700 4.25 2.53

    1800 4.39 2.441880 4.51 2.382000 4.68 2.302170 4.91 2.19

    2200 4.95 2.17

    2300 5.09 2.11

    2400 5.22 2.06

    2500 5.35 2.01

    3000 5.98 1.794000 - -

    6000 - -

    Reference :

  • 5/27/2018 Cables & Accessories

    12/38

    FEEDER CABLE 1- 5/8 RIGID

    CFC 05034 Feeder 1- 5/8

    STANDARD

    Cable with standard UV resistant PE jacket, halogen

    free according to IEC 60754

    SPECIFICATIONS

    DesignInner conductorMaterial corrugated copper tubeDiameter (mm) 17.7Dielectric

    Materialgas-injected cellular polyethy-

    leneDiameter (mm) 43.0Outer conductorMaterial corrugated copper tubeDiameter (mm) 46.6JacketMaterial black

    polyethyleneThickness (mm) 1.7Diameter (mm) 50.0

    Mechanical specicationsMinimum bending radiussingle bending (cm) 2015 repeated bends (cm) 40Maximum pulling strength (daN) 250Recommended temperature rangeStorage -70 to +85CInstallation -40 to +60COperation -55 to +85CMaximum length per hoisting grip (m) 70Maximum hanger spacing 1.5Flat plate crush resistance (kg/mm) 2.6

    Bending moment (Nm) 45Weight (kg/km) 1130

    [1] a = 0.061b = 0.000359x () = a . f + b . f [dB/100m](*) nominal values(**)Ambient temperature = 40C; Temperature of innerconductor = 100C;VSWR = 1.0; no solar loading

    Cable with UV resistant, halogen free, low smoke, ameretardant jacket according to IEC 60754-2, IEC 60332-

    1-2, IEC 60332-3 Cat. C and IEC 61034-1+2

    Electrical specicationsCharacteristic impedance () 50 1Nominal capacity (pF/m) 75Relative propagation velocity (%) 89Inductance (H/m) 0.190

    DC-resistance at 20Cinner conductor (/km) 1.37outer conductor (/km) 0.39RF peak voltage (kV) 5.5RF peak power (kW) 302Cut-off-frequency (GHz) 2.7Insulation resistance (M.km) >>5000

    Attenuation [1] and power ratingFrequency

    (MHz)Attenuation at 20C(*)(dB/100m)

    Mean power

    rating(**) (kW)10 0.20 51.53

    20 0.28 36.1730 0.34 29.3680 0.57 17.63100 0.65 15.68150 0.80 12.64200 0.93 10.84300 1.16 8.70400 1.36 7.43450 1.46 6.96500 1.54 6.56600 1.71 5.92700 1.87 5.43800 2.01 5.03

    894 2.14 4.72960 2.23 4.531000 2.29 4.431500 2.90 3.491700 3.13 3.241800 3.23 3.131880 3.32 3.052000 3.45 2.942170 3.62 2.802200 3.65 2.772300 3.75 2.702400 3.85 2.632500 3.95 2.573000 - -4000 - -6000 - -

    Reference :

    12

  • 5/27/2018 Cables & Accessories

    13/38

    COAXIAL CONNECTORS

    13

    Rfrences:

    CRA 05692 Coaxial Connector 7/16 MALE STRAIGHT 1/2 FLEXIBLECRA 05982 Coaxial Connector 7/16 MALE STRAIGHT 1/2 RIGID

    CRA 05082 Coaxial Connector 7/16 FEMALE STRAIGHT 1/2 FLEXIBLE CRA 05706 Coaxial Connector 7/16 FEMALE STRAIGHT 1/2 RIGIDCRA 05206 Coaxial Connector 7/16 MALE RIGHT- ANGLED 1/2 FLEXIBLECRA 05216 Coaxial Connector 7/16 MALE RIGHT- ANGLED 1/2 RIGID

    CRA 05721 Coaxial Connector 7/16 FEMALE STRAIGHT Clip 7/8 RIGID CRA 05720 Coaxial Connector 7/16 MALE STRAIGHT Clip 7/8 RIGIDCRA 05719 Coaxial Connector 7/16 FEMALE STRAIGHT 1-1/4 RIGIDCRA 05725 Coaxial Connector 7/16 MALE STRAIGHT 1- 1/4 RIGID

    CRA 05286 Coaxial Connector 7/16 FEMALE STRAIGHT 1-5/8 RIGIDCRA 05287 Coaxial Connector 7/16 MALE STRAIGHT 1-5/8 RIGID

    References & Specications

    7/16 F DT 7/8FEMALE STRAIGHT 7/16 F DT 1- 5/8FEMALE STRAIGHT 7/16 F DT 1- 1/4FEMALE STRAIGHT

    7/16 M CDE FLEXIBLE

    MALE RIGHT ANGLED HI-FLEX 1/2

  • 5/27/2018 Cables & Accessories

    14/38

    HIFLEX JUMPERS

    14

    Electrical Specications of Terminated Standard Jumper Cables :800-1000 MHz 1600-2000 MHz

    1 Return loss (VSWR) (typically) -32 dB (1.05: 1) -30 dB (1.06:1)

    Return loss (VSWR) (Min) -28 dB (1.08:1) -26 dB (1.1:1)2 Attenuation (per 100m) (Max) at 20C

    11.2 dB (+0.03 dB for

    connectors)17.0 dB (+0.03 dB for

    connectors)3 Power Handling (Min) continuous 750 W 500 W4 Level of IMP (Intermodulation Products)2 unmodulated test tones each at +43 dBm (20 W)3nd or higher order IMP (typically) -118 dB (-161 dBc) -118 dBm (-161 dBc)(min) -107 dBm (-150 dBc) -107 dBm (-150 dBc)5 Impedance 50 (+- 1.5 ) 50 (+- 1.5 )6 RF Voltage Rating (Peak) 1100 V 1100 V7 Velocity of Propagation 82% 82%8 Contact Potential (centre and outer conductors) no dissimilar metal interfaces

    Mechanical and Environmental specications:1 Temperature Range (Installation) -40C+60C(Operating) -45C+85C2 Relative humidity 10%100%3 General Environmental Corrosion and UV resistant4 Minimum Bending Radius 30mm5 Connector Torque (nominal) 8 Nm (N types) 15 Nm (7/16 Types)6 Packaging Orange protection caps for connectors (standard)

    Design:All metal contact parts from connectors are silver plated. Their design is optimized to provide an extra low level ofintermodulation, excellent return loss values, and improved jumper cable performances.Excellent water tightness provided by the special connector design (O-ring in connector head). The over molding of

    the connector provides an additional mechanical stability.Easy, fast and reliable installation.

    Connector 7-16, 2 Male straight

    961 005 0,5 m

    961 010 1 m

    961 015 1,5 m

    961 020 2 m

    961 025 2,5 m

    961 030 3 m

    961 040

    4 m

    961 050 5 m

    Connector 7-16, 1 Male straight

    and 1 male right angle 90961 505 0,5 m

    961 510 1 m

    961 515 1,5 m

    961 520 2 m

    961 525 2,5 m

    961 530 3 m

    961 540 4 m961 550 5 m

    References : References :

  • 5/27/2018 Cables & Accessories

    15/38

    RIGID JUMPERS

    15

    Electrical Specications of Terminated Standard Jumper Cables :800-1000 MHz 1600-2000 MHz

    1 Return loss (VSWR) (typically) -38 dB (1.02: 1) -30 dB (1.06:1)

    Return loss (VSWR) (Min) -28 dB (1.08:1) -26 dB (1.10:1)*2 Attenuation (per 100m) (Max) at 20C

    7.2 dB (+0.03 dB for

    connectors)11.5 dB (+0.03 dB for

    connectors)3 Power Handling (Min) continuous 1000 W 750 W4 Level of IMP (Intermodulation Products)2 unmodulated test tones each at +43 dBm (20 W)3nd or higher order IMP (typically) -122 dB (-165 dBc) -122 dBm (-165 dBc)(min) -112 dBm (-155 dBc) -112 dBm (-155 dBc)5 Impedance 50 (+- 1 ) 50 (+- 1 )6 RF Voltage Rating (Peak) 1100 V 1100 V7 Velocity of Propagation 88% 88%8 Contact Potential (centre and outer conductors) no dissimilar metal interfaces*-24 dB (1.12:1) for angle connectors

    Mechanical and Environmental specications:1 Temperature Range (Installation) -40C+60C(Operating) -45C+85C2 Relative humidity 10%100%3 General Environmental Corrosion and UV resistant4 Minimum Bending Radius 70 mm (single) 125 mm (repeat)5 Connector Torque (nominal) 15 Nm -25 Nm6 Packaging Orange protection caps for connectors (standard)

    Design:All metal contact parts from connectors are silver plated. Their design is optimized to provide an extra low level ofintermodulation, excellent return loss values, and improved jumper cable performances.

    Excellent water tightness provided by the special connector design (O-ring in connector head). The over molding ofthe connector provides an additional mechanical stability.Easy, fast and reliable installation.

    Connector 7-16, 2 Male Straight

    962 005 0,5 m

    962 010 1 m

    962 015 1,5 m

    962 020 2 m

    962 025 2,5 m

    962 030 3 m

    962 040 4 m

    962 050 5 m

    References :

  • 5/27/2018 Cables & Accessories

    16/3816

    RF ACCESSORIES

    Since the very beginning of the rst base stations deployments almost 20 years ago, KATHREINand its technical specialists have been developing solutions and accessories that can bring mo-bile operators and installation companies exactly what they need.There has been an increased development of products from high-performing technologies ela-borated step by step, all over the past 20 years. Their easiness and their fast installation arehighly appreciated by most of the biggest service providers and mobile operators all over theworld.

    The following chapter is basically about all RF Accessories you need on a site, from accesso-ries for Base Station Antennas, clamps for feeder cables, cable trays, to tools (stripping tools,wrench handles for connectors etc..). It will be a useful hand for technical engineers and spe-cialists, and guarantee them a safe installation, while saving time.

  • 5/27/2018 Cables & Accessories

    17/3817

    RF ACCESSORIES

    TABLE OF CONTENTS

    Second Part : RF Accessories Page 16/17

    Hoisting Grips Page 18

    Stripping Tools Page 19

    Wrench Handles for Connectors Page 20

    Instructions to use Stripping Tools Page 21

    Protection of connections Page 22

    Weatherproong Kit Page 23

    Snap-in Hangers for Feeder Cables from 1/2 to 5/8 Page 24

    Self-Locking Cable Clamps for 1, 2, 3, 4 and 6 Feeder Cables Page 25

    Cables Ties Page 26

    Wall Entries Page 27

  • 5/27/2018 Cables & Accessories

    18/38

    HOISTING GRIPS

    18

    Hoisting Grips are used to lift and hoist cables upto the top of the tower. Hoisting grips have an im-

    portant tin content, and are bronze-coated to pro-

    vide the highest resistance to corrosion. Use one

    hoisting grip every 60 meters.

    Size from 1/2 to 1-5/8 cableMaterial Tinned bronze

    Design Mesh grip with single eye support

    Include Grip, self-locking clip, tape

    Specicities pre-laced to make installation easier

    950 010 Tool 1/2950 011 Tool 7/8950 013 Tool 1-1/4950 012 Tool 1- 5/8

    Available for 1/2, 7/8, 1-5/8and 1-1/4 feeder cables

    References :

  • 5/27/2018 Cables & Accessories

    19/38

    STRIPPING TOOLS

    References :

    960 085 Tool Hi-Flex960 084 Tool Rigid960 086 Tool 1- 5/8

    960 064 Tool 7/8960 123 Tool 1- 1/4

    Tool 7/8 Tool 1- 5/8

    Tool 1/2 Hi-Flex Tool 1/2 rigid

    Tool 1- 1/4

    19

  • 5/27/2018 Cables & Accessories

    20/38

    WRENCH HANDLE FOR CONNECTORS

    20

    Connector Wrench sizemm

    Max. Wrench HeadThickness mm

    Back Nut TorqueNm

    rigid 19 7 20

    7/8 30 12 301- 1/4 44 N/A 40

    1- 5/8 58 N/A 50

    950 002 Connector 1/2950 003 Connector 7/8

    950 001 Connector 1- 5/8950 004 Connector 1- 1/4

    During the connector tightening, Hold theconnector body xed with the help of the

    torque wrench.

    References :

  • 5/27/2018 Cables & Accessories

    21/38

    INSTRUCTIONS TO USE

    STRIPPING TOOLS 7/8

    21

  • 5/27/2018 Cables & Accessories

    22/38

    PROTECTION OF CONNECTIONSGSCI closure system (Gel Seal for Coax Connectors)

    Feeders-Jumpers and Jumpers- Antennes

    22

    Reliable protection for temperature variation between -30C and 60C, without deteriorationof subsequent product performance

    Protection against excessive cable bending

    No connector disunion

    Kits are easy and quick to install, at temperatures of between -10C and +45C

    Easily removable and re-usable

    No tape, mastics or tools required for installation and re-use

    UV resistant, and tested under extremely severe conditions, vibrations and temperature cycles (acc.ICE 60068-2-14 Test Nb).

    The GSIC closure system consists of in-line closures as well as closures used to sealAntenna/ Jumper, and Jumper/ Feeder. It is designed to provide water tightness, en-vironmental and mechanical protection for coaxial connectors. By providing a long-term and effective protection against water inltration and other pollutants (IP68 acc.EN 60529), the gel guarantees a reliable and cost-effective solution.The GSIC closure system consists of the following components :

    - A wraparound central body molded from a UV-stabilized polymer.

    - A closing channel which is also molded from a UV-stabilized polymer.Sealing components :

    - The sealing is performed by a gel under compression

    - All sealing elements are integrated into the product

    CAC 05347 Antenna/ jumperCAC 05348 Jumper/ feeder cable 7/8

    CAC 05350 Jumper/ feeder cable 1- 1/4 CAC 05351 Jumper/ feeder cable 1- 5/8

    The reference CAC05347 can only beused with connectors DIN 7/16, maximumlength 60mm, maximum diameter 27mm,lowest distance between panel and connec-tor : 45mm

    References :

  • 5/27/2018 Cables & Accessories

    23/38

    WEATHERPROOFING KIT

    23

    CAC 05346 Weatherproong Kit

    Composition and technical specications:

    Butyl

    Butyl tape (0.50m x 38mm)

    Electrical tape

    Plastic electrical tape

    (10m x 15mm)

    One kit guarantees the weatherproong of:

    2 connectors 7/8 or 1 connector 1- 1/4 ou 1- 5/8

    Remove the protecting tape from the vulcanized rubber band (Butyl)

    Cover up all the connection, starting from the winding down below.Tighten steadily during the process.

    Continue the winding until you get 50 to 60 mm beyond the connector.

    Wind the plastic band in reverse of the Butyl winding.

    Cover up the Butyl with at least 3 layers of plastic band which must exceed an average of 25mm onboth sides of the rubber band.

    Stretch steadily during the winding of the rst two layers, but do not stretch the last one. Press slowlywith hand on the winding to guarantee a safe adherence all around the connector.

    Reference :

  • 5/27/2018 Cables & Accessories

    24/38

    CLAMPS FOR 1/2 TO 1- 5/8 FEEDER CABLE

    24

    Specicities:

    Machining Blanked and press-formed

    Components Fully tempered 301 stainless steel, hardened E4

    Tickness 0.8 to 1.5, according to the reference

    Assembling Stainless steel blind rivet

    Mechanical resistance Tear-off cable side > 12 Kgf

    Tear-off angle iron side > 25 Kgf

    Cable Slip > 6 Kgf

    Clamps for feeder cables designed for towers of

    angle-board type

    For cables with a diameter from 16

    to 50 mm

    Mounting : 1 clip every meter at

    the lowest.

    References :960 063 Clamps for 1/2 feeder cables960 053 Clamps for 7/8 feeder cables

    960 088 Clamps for 1- 1/4 feeder cables960 087 Clamps for 1- 5/8 feeder cables

  • 5/27/2018 Cables & Accessories

    25/38

    CLAMPS FOR 1 TO 6 FEEDERS CABLES

    25

    For at and round with thickness between 3 and

    12mm. Calibrated saddles

    CAC 05300 : Clamp for 1 feeder cable 1/2CAC 05301 : Clamp for 1 feeder cable 7/8

    CAC 05113 : Clamp for 1 feeder cable 1-1/4CAC 05110 : Clamp for 1 feeder cable 1-5/8

    Material :

    AISI 304 Stainless Steel

    Glass reinforced ber P.A, U.V resistantColor : black (grey on request)

    CAC 05121 : Clamp for 2 feeder cables 1/2CAC 05302 : Clamp for 2 feeder cables 7/8CAC 05109 : Clamp for 2 feeder cables 1-1/4CAC 05303 : Clamp for 2 feeder cables 1-5/8

    CAC 05119 : Clamp for 3 feeder cables 1/2CAC 05304 : Clamp for 3 feeder cables 7/8CAC 05315 : Clamp for 3 feeder cables 1-1/4CAC 05316 : Clamp for 3 feeder cables 1-5/8

    CAC 05122 : Clamp for 4 feeder cables 1/2CAC 05120 : Clamp for 4 feeder cables 7/8CAC 05319 : Clamp for 4 feeder cables 1-1/4CAC 05318 : Clamp for 4 feeder cables 1-5/8

    CAC 05124 : Clamp for 6 feeder cables 1/2CAC 05311 : Clamp for 6 feeder cables 7/8CAC 05317 : Clamp for 6 feeder cables 1-1/4CAC 05123 : Clamp for 6 feeder cables 1-5/8

    References :

    References :

    References :

    References :

    References :

  • 5/27/2018 Cables & Accessories

    26/38

    CABLE TIE

    26

    Technical specicationsDescription Cable tie

    Size 9 x 357 mm

    Composition Polyamide 12

    Color black

    Conditioning 100 pcs boxes

    Tightening Lowest diameter : 26 mm

    Biggest diameter : 92 mm

    CAC 05185 Cable tie

    Reference :

  • 5/27/2018 Cables & Accessories

    27/38

    WALL ENTRIES

    27

    IP67 waterproof and re resistant to REI 120

    For a tight sealing of cables

    Easy and quick mounting

    Fixings accessories are included

    Elastic cushions on separate request

    Grounding bar on request

    Description

    AISI 304 (V2A) steel plate

    Black EPDM gasket

    Elastic collarRemovable plastic PIN

    AISI 304 Hose clamp for Collar (FAS)

    Sectorial cushions (GSR & GST)

    Round cushions (GR)

    Removable protective lm

    Silicon lubricant (LUS)

    Grounding bar on request (BEI)

    CAC 05310 Wall entriesModule 6 x 2 feeder cables (7/8)

    Reference :

    Ranges from 1 to 12 feeders

  • 5/27/2018 Cables & Accessories

    28/38

    The lightning current is basically about a short and intense electromagnetic eld (of double ex-ponential type) that can damage equipment put at each ends of feeder cables, or cause a badfunctioning.

    Using components with new technologies of bad quality can easily increase the sensitivity ofelectrical and electronic equipment from lightning. Side protections limit troubles induced by thedischarge current, to a tolerable level for materials located in the extremities.

    Lightning arrester, surge protector, isolation systems are all rarely used directly. They are moreused as a whole system more or less complex and all put at the cable extremities, and close tothe equipment that need to be protected. They also need to be close, as much as possible, totheir inlet in buildings.

    These side protections can absolutely not damage the signal but indeed generate a safe ow

    path for the lightning current to the ground, to avoid damages on the cables.

    Thanks to the large choice of side protections on the market, every cable type can easily bemounted with the perfect protection. The protection depends on the signal spread by the cable(tension, current, frequency). In specic cases, the designer has between several circuit typesthat he can use, and can consequently choose the circuit with the very best specications heneeds to resolve his technical issues.

    This chapter will provide you with a complete range of products designed to protect your RFequipment against lightning, as well as weatherproong solutions, for isolation matters.

    PROTECTION

    28

  • 5/27/2018 Cables & Accessories

    29/3829

    TABLE OF CONTENTS

    Third Part : Protection of RF Equipment Page 28/29

    Copper Grounding Bar Page 30

    Universal Earthing Kit Page 31

    Earthing Kits for 1/2, 7/8, 1-1/4 & 5/8 Feeder Cables Page 32

    Lightning Arrester for GSM 900, 1800, and UMTS Page 33Lightning Arrester : Installation Instructions Page 34

    Basic Information for a safe Cell Site Page 35

    Protection of equipment upper extremities Page 36

    Cell Sites suffering from Lightning :

    How to provide a safe ow

    path for the lightning current Page 37

    OF RF EQUIPMENT

  • 5/27/2018 Cables & Accessories

    30/38

    GROUNDING BAR

    30

    960 054 Grounding bar

    Grounding bar :

    AISI 304 STAINLESS STEEL

    Reference :

    Holes :

    9 x M8

  • 5/27/2018 Cables & Accessories

    31/38

    UNIVERSAL EARTHING KIT

    921 060 Universal Earthing kit

    Kit in detail:

    1/ Contact bar of tin-plated copper

    2/ Tin-plated copper mesh

    3/ Connecting lug screw M84/ NAS self-agglomerating UV proof black color tape, for protection and sealing

    5/ P.E. insulated copper cable, length = 50cm, re resistant CEI 20-22,Color : black (green and yellow on request)6/ Tinned copper lugs

    For any type of feeder cable.

    Reference :

    31

  • 5/27/2018 Cables & Accessories

    32/38

    EARTHING KIT FOR FEEDER CABLE

    1/2, 7/8, 1- 1/4 & 1- 5/8

    32

    921 000 Feeder Cable 921 061 Feeder Cable 7/8

    921 020Feeder Cable 1- 5/8

    921 062 Feeder Cable 1- 1/4

    Compact structures

    Quick and easy installation

    Lightning tested (CESI)

    Low contact resistance < 1 mOhm

    Waterproof IP 67 (CESI)

    Corrosion resistant

    Environmental test (IEC 68-2-14)

    No extra taping needed

    Remove the section of the sheath with a knife.

    Take care not to damage the outer copper conductor of the cable.

    Carefully lubricate the cable sheet with special silicon lubricant S.

    Open the KMT contact slip and place it on the outer copper conductor of the cable.

    Close the steel shell and tighten the locking screw. Take care to well t the rubber gasket on the cablejacket.

    Fix the cable lug of the grounding wire to the ground of the tower with the M8 screw and nut.

    References :

    Technical specications:

  • 5/27/2018 Cables & Accessories

    33/38

    LIGHTNING ARRESTER FOR

    GSM 900, 1800, UMTS

    CRA 05255 lightning arrester

    Electrical specications:

    Power ow 100 KA en onde 8/20 s (1 fois)

    ROS 800 880 MHz < 1.08

    ROS 880 2500 MHz < 1.08ROS 2500 2600 MHz < 1.10

    Losses insertion < 0.05 dB

    Connection 7/16F (antenna side)7/16M (BTS side)

    Intermodulation < 160 dBc

    Mecanical specications:

    Length 105 mm

    Diameter 45 mmWeight 525 g

    IP 67

    IEC 68 558521

    Ground connection on screw M5

    conductor 6 mm minimum

    Reference :

    33

  • 5/27/2018 Cables & Accessories

    34/38

    LIGHTNING ARRESTER :

    INSTRUCTIONS FOR INSTALLATION

    Rfrences:Rfrences:

    34

    To guarantee you the best protection you can nd, the arrester has to bemounted as close as possible from the equipment that has to be protected

    (BTS).This specic equipment needs to be mounted in a safe and well-coveredplace. For Outdoor protection, use weatherproong kit

  • 5/27/2018 Cables & Accessories

    35/38

    BASIC INFORMATION FOR A SAFE SITE

    Geographical area

    Keraunic level

    The study of a lightning protection requires a study of the local geographical conditions, especially the

    exposure degree of the structure to :- the lightning risk, to assess the potential for risk, useful in the specication of protection devices,- the winds, studying the structures architecture to determine the best mechanical design of the device

    Knowing the exact geographical position of the site to protect is determining for the keraunic level. Thekeraunic level Nk indeed expresses the number of days per year where thunder is heard at a given place.This level indicates the degree of protection (site strongly or not strongly exposed) and make possible to

    calculate the lightning density Ng, which expresses the number of strikes per year per km.

    Wind direction

    Knowing the prevailing winds in thundery periods is less important than the keraunic level. But it can help

    to change the position of each protection. Indeed, every calculation on lightning rods consider clap of thun-

    der as vertical. However, they are lightly deected by aerological phenomenon.

    Site geology

    Two factors have to be considered on a geological level.

    Ground resistance

    It is a determining point to take decision regarding the ground plugs size, which provides a safe ow pathfor the lightning current.

    Homogeneous Land surface

    It is very important regarding the ground plug location; resistance between ground plugs will highly inter-

    fere with the differences of potential, included between buildings when lightning strikes.

    Site environment : building and surroundings

    Building sizes (length, height, and width), terrace plans, towers and shelters positioning, and basically allheight measurements are necessary guidelines for the survey. The plan will have to include the indication

    of the north, the surrounding facilities (water supply, electric power station).

    35

  • 5/27/2018 Cables & Accessories

    36/38

    PROTECTION OF HEAD END EQUIPMENT

    Phenomenon:

    Lightning currents cause a short and intense electromagnetic eld which is double exponential, that candamage head-end equipment connected to cables. Using high tech components from bad quality can

    easily increase the severe impact of lightning on electrical and electronic equipment.

    Head-end equipment are involved to limit disturbances caused by lightning, until you get an acceptable

    level that head-end equipment can handle.

    Physical magnitude

    Peak value for 1 lightning strike 35 KA

    Time of climb 100 ns to 100 s

    Time 10 s to 100 ms

    Spectrum 1 KHz to 1 MHz (Maximum weight about 100 KHz)

    Main information on head-end equipment

    Lightning Arrester (association between spark gap and varistor)

    Surge Suppressor (transient voltage suppression diode)

    Isolation systems (slightly capacitive transformers or lines connected for microwave links

    applications).

    Lightning arrester, surge protector, isolation systems are all rarely used directly. They are more used as a

    whole system more or less complex and all put at the cable extremities, and close to the equipment thatneed to be protected.

    They also need to be close, as much as possible, to their inlet in buildings.

    These side protections can absolutely not damage the signal but indeed generate a safe ow path for thelightning current to the ground, to avoid damages on the cables.

    Thanks to the large choice of side protections on the market, every cable type can easily be mounted with

    the perfect protection. The protection depends on the signal spread by the cable (tension, current, fre-

    quency). In specic cases, the designer has between several circuit types that he can use, and can conse-quently choose the circuit with the very best specications he needs to resolve his technical issues.

    36

  • 5/27/2018 Cables & Accessories

    37/38

    CELL SITES SUFFERING FROM LIGHTNINGHow to provide a safe ow path for the lightning current

    37

    Pylon Protection

    Lightning Rod (Basic Metal Rod)

    Meplat 30x2mm

    Copper Square Clamps

    Crow-foot earthing system

    Meplat 30x2mm

    Connector Copper Ground Rod

    Inspection Hole

    Oblong Test Clamp

    Earthing Kit

    Steel Strapping Tapes

    Lateral Fixing Brackets

  • 5/27/2018 Cables & Accessories

    38/38

    En raison de lvolution technique, KATHREIN se rserve le droit toutmoment et sans pravis de modier les caractristiques techniques

    annonces pour ces produits et/ ou de cesser la fabrication de ceux-ci.

    KATHREIN France

    7, rue des Gardes

    F-91370 VERRIERES LE BUISSON

    France

    Tl. +33 1 69 53 64 53