The Caleffi Solar product range has been specially developed for use in solarthermal systems, where high temperatures can normally be reached and where,depending on the kind of system, there can be glycol. Materials and performanceof the components must necessarily take into account these particular operatingconditions.
COMPONENTS FOR PRIMARY CIRCUIT
Automaticfilling
SOLCAL 1
OFF
ON
TEST
75∞ 65∞12∞
0
20
40
6080
100
120
140
160 0
20
40
6080
100
120
140
160conforme norme ISPES L
0
2
4 6
8
10
bar
CL 2.5
3
7
6
5
4
3
2
We reserve the right to make changes and improvements to the products and related data in this publication, at any time and without prior notice.All the diagrams, numerical data, etc., are not binding.
2
AIR VENTS - SAFETY RELIEF VALVE - DEAERATORS
251003 3/4” F
251 tech. broch. 01134
DISCAL®
Deaerator for solar thermal systems.Brass body. Chrome plated.Female connections.Max. working pressure: 10 bar.Max. discharge pressure: 10 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.
Code
251006251007
1” F1 1/4” F
251 tech. broch. 01134
DISCAL®
Deaerator for solar thermal systems.Brass body. Chrome plated.Female connections.With drain.Max. working pressure: 10 bar.Max. discharge pressure: 10 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.
Code
251004 1/2” F
251 tech. broch. 01135
DISCALAAIIRR®
High-performance automatic air vent for solar thermal systems. Brass body.Chrome plated. Female connections.Max. working pressure: 10 bar.Max. discharge pressure: 10 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.
Code
250031250131
3/8” M without cock3/8” M
250 tech. broch. 01133
Consisting of:- Automatic air vent for solar thermalsystems.
Brass body. Chrome plated.Max. working pressure: 10 bar.Max. discharge pressure: 5 bar.Temperature range: -30–180°C.Max. percentage of glycol: 50%.- Shut-off cock complete with seal.Brass body. Chrome plated.Max. working pressure: 10 bar.Temperature range: -30–200°C.Max. percentage of glycol: 50%.
Code
253042253043253044253046253048253040253052253053253054253056253058253050
1/2” F x 3/4” F1/2” F x 3/4” F1/2” F x 3/4” F1/2” F x 3/4” F1/2” F x 3/4” F1/2” F x 3/4” F3/4” F x 1” F3/4” F x 1” F3/4” F x 1” F3/4” F x 1” F 3/4” F x 1” F3/4” F x 1” F
2,5 bar3 bar4 bar6 bar8 bar10 bar2,5 bar3 bar4 bar6 bar8 bar10 bar
253 tech. broch. 01089
Safety relief valve for solar thermal systems.Brass body. Chrome plated.Female connections. PN 10.Temperature range: -30–160°C.Max. percentage of glycol: 50%.Oversized discharge outlet.Discharge rating: 1/2” - 50 kW.
3/4” - 100 kW.TÜV certified to SV100 7.7No. TÜV SV 07 2009 · SOL · H · p.Settings: 2,5 - 3 - 4 - 6 - 8 - 10 bar.
Code
11
15
250300250400
3/8” M x 3/8” F - batterfly handle1/2” M x 1/2” F - lever handle
250 tech. broch. 01133
Shut-off cock complete with seal.Brass body. Chrome plated.Max. working pressure: 10 bar.Temperature range: -30–200°C.Max. percentage of glycol: 50%.
Code
251905251906
3/4” F1” F
251 tech. broch. 01134
DISCAL®
Deaerator for vertical pipes, for solar thermal systems.Brass body. Chrome plated.Female connections.Max. working pressure: 10 bar.Max. discharge pressure: 10 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.
Code
The automatic air vent must be shut off afterthe system has been filled.
3
251093 3/4” F
Code
251 tech. broch. 01197
Manual air separator.Brass body.Female connections.Max. working pressure: 10 bar.Max. discharge pressure: 10 bar.Temperature range: -30÷200°C.Max. percentage of glycol: 50%.
267Pump station for solar thermal systems, flow and return connection,with solar controller.Supply: 230 V (ac).Max. working pressure: 10 bar.Safety relief valve temperature range: -30–160°C.Safety relief valve setting: 6 bar(for other setting, see 253 series using the adaptercode F21224).Balancing valve with flow meter temperaturerange: -30–130°C.Max. percentage of glycol: 50%.
Consisting of:- Solar 15-80 circulation pump;- safety relief valve for solar thermal systems 253 series;- 2 fill/drain cocks;- instrument holder fitting with pressure gauge;- balancing valve with graduated scale flow meterwith magnetic movement flow rate indicator;- deaerator device;- flow temperature gauge;- return temperature gauge;- 2 shut-off valves and check valve;- pre-formed shell insulation;
- digital controller DeltaSol® C+ with probes.
267Pump station for solar thermal systems, flow and return connection.Supply: 230 V (ac).Max. working pressure: 10 bar.Safety relief valve temperature range: -30–160°C.Safety relief valve setting: 6 bar(for other setting, see 253 series using the adaptercode F21224).Balancing valve with flow meter temperaturerange: -30–130°C.Max. percentage of glycol: 50%.
Consisting of:- Solar 15-80 circulation pump;- safety relief valve for solar thermal systems 253 series;- 2 fill/drain cocks;- instrument holder fitting with pressure gauge;- balancing valve with graduated scale flow meterwith magnetic movement flow rate indicator;- deaerator device;- flow temperature gauge;- return temperature gauge;- 2 shut-off valves and check valve;- pre-formed shell insulation.
PUMP STATIONS
267250267254267252
3/4” F3/4” F3/4” F
2–17 3–107–25
Flow meter scale(l/min)Code
267050267054267052
3/4” F3/4” F3/4” F
2–17 3–107–25
Flow meter scale(l/min)Code
4
PUMP STATIONS
266250266254266252
3/4” F3/4” F3/4” F
2–17 3–107–25
Flow meter scale(l/min)Code
266050266054266052
3/4” F3/4” F3/4” F
2–17 3–107–25
Flow meter scale(l/min)Code
266Pump station for solar thermal systems, return connection,with solar controller.Supply: 230 V (ac).Max. working pressure: 10 bar.Safety relief valve temperature range: -30–160°C.Safety relief valve setting: 6 bar(for other setting, see 253 series using the adaptercode F21224).Balancing valve with flow meter temperaturerange: -30–130°C.Max. percentage of glycol: 50%.
Consisting of:- Solar 15-80 circulation pump;- safety relief valve for solar thermal systems 253 series;- 2 fill/drain cocks;- instrument holder fitting with pressure gauge;- balancing valve with graduated scale flow meterwith magnetic movement flow rate indicator;- return temperature gauge;- shut-off valves and check valve;- pre-formed shell insulation;
- digital controller DeltaSol® C+ with probes.
266Pump station for solar thermal systems, return connection.Supply: 230 V (ac).Max. working pressure: 10 bar.Safety relief valve temperature range: -30–160°C.Safety relief valve setting: 6 bar(for other setting, see 253 series using the adaptercode F21224).Balancing valve with flow meter temperaturerange: -30–130°C.Max. percentage of glycol: 50%.
Consisting of:- Solar 15-80 circulation pump;- safety relief valve for solar thermal systems 253 series;- 2 fill/drain cocks;- instrument holder fitting with pressure gauge;- balancing valve with graduated scale flow meterwith magnetic movement flow rate indicator;- return temperature gauge;- shut-off valves and check valve;- pre-formed shell insulation.
5
269Pump station for solar thermal systems, flow and return connection, with solar controller.Supply: 230 V (ac).Max. working pressure: 10 bar.Safety relief valve temperature range: -30–160°C.Safety relief valve setting: 6 bar(for other setting, see 253 series).Flow meter temperature range: -10–110°C.Max. percentage of glycol: 50%.
Consisting of:- Solar 15-65 circulation pump;- safety relief valve for solar thermal systems 253 series;- 2 fill/drain cocks;- instrument holder fitting with pressure gauge;- flow meter;- deaerator device;- flow temperature gauge;- return temperature gauge;- 2 shut-off valves and check valve;- 2 hose connections;- pre-formed shell insulation;
- digital controller DeltaSol® C+ with probes.
269Pump station for solar thermal systems, flow and return connection.Supply: 230 V (ac).Max. working pressure: 10 bar.Safety relief valve temperature range: -30–160°C.Safety relief valve setting: 6 bar(for other setting, see 253 series).Flow meter temperature range: -10–110°C.Max. percentage of glycol: 50%.
Consisting of:- Solar 15-65 circulation pump;- safety relief valve for solar thermal systems 253 series;- 2 fill/drain cocks;- instrument holder fitting with pressure gauge;- flow meter;- deaerator device;- flow temperature gauge;- return temperature gauge;- 2 shut-off valves and check valve;- 2 hose connections;- pre-formed shell insulation.
PUMP STATIONS
269250 3/4” F 1–13
Flow meter scale(l/min)Code
269050 3/4” F 1–13
Flow meter scale(l/min)Code
6
PUMP STATIONS
268250 3/4” F 1–13
Flow meter scale(l/min)Code
268050 3/4” F 1–13
Flow meter scale(l/min)Code
268Pump station for solar thermal systems, return connection, with solar controller.Supply: 230 V (ac).Max. working pressure: 10 bar.Safety relief valve temperature range: -30–160°C.Safety relief valve setting: 6 bar(for other setting, see 253 series).Flow meter temperature range: -10–110°C.Max. percentage of glycol: 50%.
Consisting of:- Solar 15-65 circulation pump;- safety relief valve for solar thermal systems 253 series;- fill/drain cock;- instrument holder fitting with pressure gauge;- flow meter;- return temperature gauge;- shut-off valve and check valve;- 2 hose connections;- pre-formed shell insulation;
- digital controller DeltaSol® C+ with probes.
268Pump station for solar thermal systems, return connection.Supply: 230 V (ac).Max. working pressure: 10 bar.Safety relief valve temperature range: -30–160°C.Safety relief valve setting: 6 bar(for other setting, see 253 series).Flow meter temperature range: -10–110°C.Max. percentage of glycol: 50%.
Consisting of:- Solar 15-65 circulation pump;- safety relief valve for solar thermal systems 253 series;- fill/drain cock;- instrument holder fitting with pressure gauge;- flow meter;- return temperature gauge;- shut-off valve and check valve;- 2 hose connections;- pre-formed shell insulation.
7
259 tech. broch. 01136
Welded expansion vessel only for primarycircuit of solar thermal systems.Diaphragm certified to DIN 4807-3 standard.Max. working pressure: 10 bar.Diaphragm max. temperature: 100°C. System temperature range: -10–120°C.Max. percentage of glycol: 50%.
259012259018259024259035259050
3/4”3/4”3/4”3/4”3/4”
1218243550
Code Litres Conn.
2,52,52,52,52,5
Precharge(bar)
255010
255System filling pump for pump stations 266 and 267 series.
Code
ACCESSORIES FOR PUMP STATIONS
Adapter for pump stations 266 and 267 series.To be used with safety relief valve 253 series, 1/2”.
F21224
Code
240 tech. broch. 01185
Ball valve for solar thermal system.Body and ball in stainless steel AISI 316.
PN 63.Female connections.Handle in stainless steel AISI 304.Temperature range: -30–200°C.Max. percentage of glycol: 50%.
BALL VALVE AND THREE-PIECE UNION FITTING
588052588062
3/4” F x M with union1” F x M with union
588Three-piece straight union fitting for solar thermal systems.Max. working pressure: 16 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.Black nickel plated nut.
Code
240400240500240600
Code
1/2”3/4”1”
8
255 tech. broch. 01136
Expansion vessel connection kit.Consisting of:- stainless steel flexible hose (L=500 mm); - automatic shut-off cock;- wall mounting bracket (for vessels up to 24 litres).
Max. working pressure: 10 bar.Shut-off cock max. working temperature:110°C.Max. percentage of glycol: 50%.
255001 3/4”
Code
BALANCING VALVE WITH FLOW METER
258 tech. broch. 01148
Balancing valve with flow meter, for solar thermal systems. Direct reading of flow rate.Brass valve body and flow meter.Chrome plated.Ball valve for flow rate adjustment.Graduated scale flow meter with magneticmovement flow rate indicator.
With insulation.Max. working pressure: 10 bar.Temperature range: -30–130°C.Max. percentage of glycol: 50%.Patent application No. MI2007A000703.
3/4”3/4”3/4”1”
258503258533258523258603
Code
12–0713–1017–2810–40
Flow rate range(l/min)
1/2”3/4”1”
Conn.
755254755255755256
Code
1,52,53,5
Qnom m3/h
single jet
single jet
multi jet
Meas. type
HEAT METER
75525 CONTECA tech. broch. 01146
Direct heat metering with local LCD reading by means orcentralised reading with controller code 755010 or interfacecode 755055, for solar thermal systems.
Max. working pressure: 10 bar.Temperature range: 5–120°C.Max. percentage of glycol: 50%.
The CONTECA module is supplied complete with:- Pair of temperature probes with immersion pockets.- Y pockets for immersion probes. - Water meter, with pulse output (max. temperature 120°C).- Electronic integrator with LCD.- Supply 24 V (ac) 50 Hz - 1 W. - Set for transmission in RS485 Bus mode. Conformity to EN 1434-1.
9
10
DIGITAL CONTROLLER
257041
257SOLCAL® 1Digital controller for solar thermal systems.Complete with wall mounting basis for plug-in electrical connection.Complete with three probes type Pt1000.Double relays output.Supply: 230 V ±6% - 50 Hz.Power consumption: 4 VA.Max. contact rating: 250 V (ac) - 8 (2) A.Protection class: IP 40.
Code
Characteristic components
Regulation programsThe controller allows to manage 11 regulation programs,depending on the possible system configurations. They can beused for systems with single or double storage, swimming-pools,heating or domestic water systems, etc..
257Pocket for Pt1000 probe.In steel.Lenght: 100 mm.
257004
Code
90 x 136 x 80 1/2”
(h x w x d)
11) LED 1: function error or probe fault (red) 12) LED 2: Solar circuit pump ON13) LED 3: second relays output active14) LED 4: OFF regulator non active15) LED 5: ON regulator active16) LED 6: active relays test17) Storage temperature control setting at level 1,
at level 2 depending on programme (see system)18) ∆T min. and max. control19) Min. temperature control for solar panel activation
and min. working time10) Operation button
DIFFERENTIAL REGULATORS AND THERMOSTAT
257000
257 tech. broch. 01143
Differential temperature regulator for solarthermal systems, with relays output.Box protection class: IP 65.Supply: 230 V ±6% - 50 Hz.Nominal power consumption: 1,45 VA.Contact rating on switch-over: 6 A (230 V).∆T adjustment range: 2–20 K.Hysteresis: 2 K (±1 K).
Code
257002
257 tech. broch. 01143
Thermostat for solar thermal systems, with relays output. For thermal integrationcontrol and diverter valves.Box protection class: IP 65.Supply: 230 V ±6% - 50 Hz.Nominal power consumption: 1,45 VA.Contact rating on switch-over: 6 A (230 V).Adjustment temperature range: 20–90°C.Hysteresis: 1 K.
Code
257010
257 tech. broch. 01143
Differential temperature regulator for solarthermal systems, with relays output.Complete with contact probe and immersion probe with pocket.Box protection class: IP 65.Supply: 230 V ±6% - 50 Hz.Nominal power consumption: 1,45 VA.Contact rating on switch-over: 6 A (230 V).∆T adjustment range: 2–20 K.Hysteresis: 2 K (±1 K).
Code
257001
257 tech. broch. 01143
Box complete with DIN bar,for regulator or thermostat 257 series. Protection class: IP 65.
Code
257003
257 tech. broch. 01143
Double box complete with DIN bar,for regulator and thermostat 257 series. Protection class: IP 65.
Code
150 tech. broch. 01143
Contact probe for regulator or thermostat 257 series and for regulator 1520 series(flow or return).Cable lenght: 2 m.
150 tech. broch. 01143
Immersion probe for regulator or thermostat 257 series and for regulator 1520 series.Cable lenght: 2 m.
150009
Code
150006
Code
150 tech. broch. 01143
Pocket for immersion probe code 150006.
150029 1/4” M
Code
200 x 122 x 112
(h x w x d)
200 x 160 x 112
(h x w x d)
11
12
254305254308254302
Code
Ø 15Ø 18Ø 22
2545Elbow coupling sleeve, mechanical O-Ring seal for solar thermal systems. For annealed copper, hard copper,brass, mild and stainless steel pipes.Max. working pressure: 16 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.Black nickel plated nut.
254505254508254502
Code
Ø 15Ø 18Ø 22
2544Male fitting, mechanical O-Ring seal for solar thermal systems. For annealed copper, hard copper, brass, mild and stainless steel pipes.Max. working pressure: 16 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.Black nickel plated nut.
254455254458254452254465254462
Code
3/4” M - Ø 153/4” M - Ø 183/4” M - Ø 221” M - Ø 151” M - Ø 22
2547Male elbow fitting, mechanical O-Ring seal for solar thermal systems. For annealed copper, hard copper,brass, mild and stainless steel pipes.Max. working pressure: 16 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.Black nickel plated nut.
254755254758254752
Code
3/4” M - Ø 153/4” M - Ø 183/4” M - Ø 22
2548Female elbow fitting, mechanical O-Ring seal for solar thermal systems. For annealed copper, hard copper,brass, mild and stainless steel pipes.Max. working pressure: 16 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.Black nickel plated nut.
254855254858254852
Code
3/4” F - Ø 153/4” F - Ø 183/4” F - Ø 22
FITTINGS
2543Coupling sleeve, mechanical O-Ring sealfor solar thermal systems. For annealed copper, hard copper, brass, mild and stainless steel pipes.Max. working pressure: 16 bar.
Temperature range: -30–160°C.Max. percentage of glycol: 50%.Black nickel plated nut.
2540Female fitting, mechanical O-Ring sealfor solar thermal systems. For annealed copper, hard copper, brass, mild and stainless steel pipes.Max. working pressure: 16 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.Black nickel plated nut.
254055254058254052254062254068
Code
3/4” F - Ø 153/4” F - Ø 183/4” F - Ø 221” F - Ø 221” F - Ø 28
Ø 22254002
2540Plug for Ø 22 copper pipe.
Code
2546Tee fitting,mechanical O-Ring seal for solar thermal systems.
For annealed copper, hard copper, brass, mild and stainless steel pipes.Max. working pressure: 16 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.Black nickel plated nut.
254505254508254502
Code
Ø 15Ø 18Ø 22
COMPONENTS FOR SECONDARY CIRCUIT
Normally closedvalve
Diverter on thesecondary circuit
SOLARSTORAGE
13
THERMOSTATIC MIXING VALVE
ANTI-SCALD THERMOSTATIC MIXING VALVE
2527 tech. broch. 01165
Anti-scald adjustable thermostaticmixing valve, with check valves andstrainers, for solar thermal systems. High thermal performance device,with anti-scald safety function.
dezincification resistant alloy body.Chrome plated.Male union connections.Performance to standards NF 079 Doc. 8,EN 15092, EN 1111, EN 1287.Max. working pressure: 10 bar.Max. inlet temperature: 100°C.
Code
252714252713
1/2”3/4”
35–55°C35–55°C
1,51,7
Kv (m3/h)Temperatureadjustment
252140252150
2521 tech. broch. 01127
Adjustable thermostatic mixing valvefor solar thermal systems.
dezincification resistant alloy body.Chrome plated.Male union connections.Max. working pressure: 14 bar.Max. inlet temperature: 100°C.
Code
1/2”3/4”
30–65°C30–65°C
2,62,6
Kv (m3/h)Temperatureadjustment
252153
2521 tech. broch. 01127
Adjustable thermostatic mixing valve, with check valves, for solar thermal systems.
dezincification resistant alloy body.Chrome plated.Male union connections.Max. working pressure: 14 bar.Max. inlet temperature: 100°C.
Code
3/4” 30 –65°C 2,6
Kv (m3/h)Temperatureadjustment
252340252350252360252370252380252390
Code
1/2”3/4”1”1 1/4”1 1/2”2”
1/2” - 3/4”
30–65°C30–65°C30–65°C30–65°C35–65°C35–65°C
14,014,516,919,114,519,0
Kv (m3/h)Temperatureadjustment
2523 tech. broch. 01129
Thermostatic mixing valve withinterchangeable cartridge for solar thermal systems.
Brass body. Chrome plated.Male union connections.Max. working pressure: 14 bar.Max. inlet temperature: 110°C.
252305
2523Spare cartridge.For thermostatic mixing valve 2523 series.
Code
2523Spare cartridge.For thermostatic mixing valve 2523 series.
1” - 1 1/4”1 1/2” - 2”
252306252308
Code
14
MOTORISED BALL DIVERTERVALVE
6443 tech. broch. 01132
Motorised three-way ball diverter valve.Max. working pressure: 10 bar.Max. ∆p: 10 bar.Temperature range: -5–110°C.
Complete with actuator with 3-contact control.With auxiliary microswitch.Electric supply: 230 V (ac).Power consumption: 8 VA.Auxiliary microswitch contact rating: 0,8 A (230 V).Ambient temperature range: 0–55°C.
Protection class: IP 44 (vertical stem).IP 40 (horizontal stem).Operating time: 10 s (90° rotation). Cable lenght: 100 cm.Patent application No. MI2005A001282.
644346644356644357644366
1/2”3/4”3/4”1”
230230230230
3,93,98,69,0
Code Kv (m3/h)Electric supply
V
309461309471309401309561309571309501
1/2” M x Ø 15 6 bar1/2” M x Ø 15 7 bar1/2” M x Ø 15 10 bar3/4” M x Ø 22 6 bar3/4” M x Ø 22 7 bar3/4” M x Ø 22 10 bar
Code
TEMPERATURE AND PRESSURERELIEF VALVE
309 tech. broch. 01147
Temperature and pressure relief valve.For solar thermal systems, for protecting the hot water storage.
dezincification resistant alloy body. Chrome plated.Set temperature: 90°C.Discharge rating: 1/2” x Ø 15: 10 kW.
3/4” x Ø 22: 25 kW.Settings: 6 - 7 - 10 bar.Settings certified to EN 1490: 7 - 10 bar.
11
15
15
SOLAR STORAGE-BOILER CONNECTION KIT
a aa a a aa a aaApplication diagram of SOLARNOCAL kit 264 series
Hydraulic diagrams
M D
BOILER
USERSOLAR
TSOLAR > 45°C
M D
BOILER
USERSOLAR
TSOLAR < 45°C
COLDCOLD
MIX
264352
Code
3/4”
264 tech. broch. 01163
SOLARNOCAL
Function
A thermostatic anti-scald mixing valve, at the kit inlet, controls thetemperature of the water coming from the solar hot water storage.The thermostat, by means of the probe positioned on the hot waterflow from the solar hot water storage, controls the diverter valve atthe kit outlet. Depending on the temperature setting, the valvediverts the water towards the user circuit or activates the boilercircuit, without thermal integration.
Solar storage-boiler connection kit, without thermal integration.Consisting of:- thermostatic anti-scald mixing valve, adjustable with knob, for solar thermal systems. Complete with strainers and check valves at the inlets;
- diverter valve with three-contact actuator, with auxiliary microswitch;- thermostat with probe for solar thermal system, for operating diverter valve. Display showing temperature.
- pre-formed shell protective cover.
Diverter-mixing valve coupling with adjustable position of theinlet and outlet connections.
Mixing valvedezincification resistant alloy body. Chrome plated.
Max. working pressure: 10 bar.Adjustment temperature range: 35–55°C.Max. inlet temperature: 100°C.
Diverter valveBrass body. Chrome plated.Max. working pressure: 10 bar.Temperature range: -5–110°C.
ActuatorThree-contact type.Supply: 230 V (ac).Power consumption: 8 VA.Auxiliary microswitch contact rating: 0,8 A (230 V).Ambient temperature range: 0–55°C.Protection class: IP 44 (vertical stem).
IP 40 (horizontal stem).Operating time: 10 s.Cable lenght: 1 m.
Thermostat with probeSupply: 230 V (ac).Adjustable temperature range: 25–50°C.Factory setting: 45°C. Box protection class: IP 54.
Patent application No. MI2007A000936.
16
SOLAR STORAGE-BOILER CONNECTION KIT
265 tech. broch. 01163
SOLARINCAL
Function
The thermostat, by means of the probe positioned on the hot waterflow from the solar hot water storage, controls the diverter valve atthe kit inlet. Depending on the temperature setting, the valve divertsthe water towards the user circuit or the boiler circuit, with thermalintegration.A thermostatic anti-scald mixing valve, at the kit outlet, constantlycontrols the temperature of the water sent to the user.a aa a aa aaaApplication diagram of SOLARINCAL kit 265 series
Solar storage-boiler connection kit, with thermal integration.Consisting of:- thermostatic anti-scald mixing valve, adjustable with knob, for solarcthermal systems. Complete with strainers and check valves at the inlets;
- diverter valve with three-contact actuator, with auxiliary microswitch;- thermostat with probe for solar thermal system, for operatingdiverter valve. Display showing temperature.
- pre-formed shell protective cover.
Diverter-mixing valve coupling with adjustable position of theinlet and outlet connections.
Mixing valveFor technical details see 264 series.
Diverter valveFor technical details see 264 series.
ActuatorFor technical details see 264 series.
Thermostat with probeSupply: 230 V (ac).Adjustable temperature range: 25–50°C.Factory setting: 45°C.Box protection class: IP 54.
Patent application No. MI2007A000936.
MD
BOILER
SOLAR
TSOLAR > 45°C
MIXED
COLDM
D
BOILER
SOLAR
TSOLAR < 45°C
MIXED
COLD
265352
Code
3/4”
Hydraulic diagrams
265001
Code
264359265359F29525F29488257004
Code
kit 264 series without thermostat and probe
kit 265 series without thermostat and probe
box with switching 3 contact relay
Ø 6 mm probe
pocket probe
265Thermostat with display showing storage temperature.For devices 264 and 265 series.Supply: 230 V (ac).Adjustable temperature range: 25–50°C.Factory setting: 45°C.Box protection class: IP 54.
ACCESSORIES
17
SOLAR STORAGE-BOILER THERMOSTATIC CONNECTION KIT
COLDMIXED COLD
WATERINLET
a aa a aa aaApplication diagram of SOLARINCAL-T serie 262
262350
Code
3/4”
262 tech. broch. 01164
SOLARINCAL-T
Function
A thermostatic diverter valve, at the kit inlet, receives hot watercoming from the solar water storage.Depending on the temperature setting, the valve diverts the waterautomatically and in a proportional manner towards the user circuitor the boiler with storage circuit, with thermal integration.The valve modulates the flow rates to optimise the energycontained in the solar storage and reduce boiler operation times toa minimum.A thermostatic anti-scald mixing valve, at the kit outlet, constantlycontrols and limits the temperature of the water sent to the user.
Solar storage-boiler connection kit, with thermal integration.Consisting of:- thermostatic anti-scald mixing valve, adjustable with knob, for solar thermal systems. Complete with strainers and check valves at the inlets.
- thermostatic diverter valve;- pre-formed shell protective cover.
Diverter-mixing valve coupling with adjustable position of theinlet and outlet connections.
Mixing valvedezincification resistant alloy body. Chrome plated.
Max. working pressure: 10 bar.Adjustment temperature range: 35–55°C.Max. inlet temperature: 100°C.Performance to standards NF 079 doc. 8, EN 15092, EN 1111, EN 1287.
Diverter valveBrass body. Chrome plated.Max. working pressure: 10 bar.Factory setting: 45°C.Max. inlet temperature: 100°C.
Hydraulic diagrams
TSOLAR > 45°C TSOLAR < 45°C
M
BOILER
SOLARMIXED
COLD
M
BOILER
SOLARMIXED
COLD
DD
18
SOLAR STORAGE-BOILER THERMOSTATIC CONNECTION KIT
aa aa aaCOLDMIXED COLD
WATERINLET
MODULATINGBOILER
INGRESSOFREDDAFREDDA
MISCELATA
Valvola normalmente chiusa
Application diagram of SOLARINCAL-T Plus kit 263 series
263 tech. broch. 01164
SOLARINCAL-T PPLLUUSS
Function
A thermostatic diverter valve, at the kit inlet, receives hot watercoming from the solar water storage. Depending on thetemperature setting, the valve diverts the water automatically andproportionally towards the user circuit or the instantaneous boilercircuit, with thermal integration. The valve modulates the flowrates to optimise the energy contained in the solar storage andreduce boiler operation times to a minimum. A specific thermostatic control device limits the boiler inlettemperature to prevent it being switched on and off too often, whichleads to hunting and irregular operation. A thermostatic anti-scald mixing valve, at the kit outlet, constantlycontrols the temperature of the water sent to the user.
Solar storage-boiler connection kit, with thermal integration.Consisting of:- thermostatic anti-scald mixing valve, adjustable with knob, for solar thermal systems. Complete with strainers and check valves at the inlets;
- thermostatic diverter valve;- thermostatic control device;- pre-formed shell protective cover.
Mixing valvedezincification resistant alloy body. Chrome plated.
Max. working pressure: 10 bar.Adjustment temperature range: 35–55°C.Max. inlet temperature: 100°C.Performance to standards NF 079 doc. 8, EN 15092, EN 1111, EN 1287.
Diverter valvedezincification resistant alloy body. Chrome plated.
Max. working pressure: 10 bar.Factory set: 45°C.Max. inlet temperature: 100°C.
Control devicedezincification resistant alloy body. Chrome plated.
Factory setting: 30°C.Max. inlet temperature: 85°C.
Patent application No. MI2008A001813.
263350
Code
3/4”
Hydraulic diagrams
TSOLAR > 45°C TSOLAR < 45°C
M
BOILER
SOLARMIXED
COLD
M
BOILER
SOLARMIXED
COLD
D DC C
19
0311711G
B
Caleffi S.p.A. S.R. 229 n. 25 28010 Fontaneto D’Agogna (NO) Italy Tel. +39 0322 8491 Fax +39 0322 863723
· www.caleffi.com · [email protected] ·
© Copyright 2011 Caleffi