COMPONENTS FOR SOLAR THERMAL SYSTEMS 2011
Transcript
Page 1: Caleffi International NV - Brochure Solar

COMPONENTSFOR SOLAR THERMAL SYSTEMS

2011

Page 2: Caleffi International NV - Brochure Solar

The Caleffi Solar product range has been specially developed for use in solarthermal systems, where high temperatures can normally be reached and where,depending on the kind of system, there can be glycol. Materials and performanceof the components must necessarily take into account these particular operatingconditions.

COMPONENTS FOR PRIMARY CIRCUIT

Automaticfilling

SOLCAL 1

OFF

ON

TEST

75∞ 65∞12∞

0

20

40

6080

100

120

140

160 0

20

40

6080

100

120

140

160conforme norme ISPES L

0

2

4 6

8

10

bar

CL 2.5

3

7

6

5

4

3

2

We reserve the right to make changes and improvements to the products and related data in this publication, at any time and without prior notice.All the diagrams, numerical data, etc., are not binding.

2

Page 3: Caleffi International NV - Brochure Solar

AIR VENTS - SAFETY RELIEF VALVE - DEAERATORS

251003 3/4” F

251 tech. broch. 01134

DISCAL®

Deaerator for solar thermal systems.Brass body. Chrome plated.Female connections.Max. working pressure: 10 bar.Max. discharge pressure: 10 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.

Code

251006251007

1” F1 1/4” F

251 tech. broch. 01134

DISCAL®

Deaerator for solar thermal systems.Brass body. Chrome plated.Female connections.With drain.Max. working pressure: 10 bar.Max. discharge pressure: 10 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.

Code

251004 1/2” F

251 tech. broch. 01135

DISCALAAIIRR®

High-performance automatic air vent for solar thermal systems. Brass body.Chrome plated. Female connections.Max. working pressure: 10 bar.Max. discharge pressure: 10 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.

Code

250031250131

3/8” M without cock3/8” M

250 tech. broch. 01133

Consisting of:- Automatic air vent for solar thermalsystems.

Brass body. Chrome plated.Max. working pressure: 10 bar.Max. discharge pressure: 5 bar.Temperature range: -30–180°C.Max. percentage of glycol: 50%.- Shut-off cock complete with seal.Brass body. Chrome plated.Max. working pressure: 10 bar.Temperature range: -30–200°C.Max. percentage of glycol: 50%.

Code

253042253043253044253046253048253040253052253053253054253056253058253050

1/2” F x 3/4” F1/2” F x 3/4” F1/2” F x 3/4” F1/2” F x 3/4” F1/2” F x 3/4” F1/2” F x 3/4” F3/4” F x 1” F3/4” F x 1” F3/4” F x 1” F3/4” F x 1” F 3/4” F x 1” F3/4” F x 1” F

2,5 bar3 bar4 bar6 bar8 bar10 bar2,5 bar3 bar4 bar6 bar8 bar10 bar

253 tech. broch. 01089

Safety relief valve for solar thermal systems.Brass body. Chrome plated.Female connections. PN 10.Temperature range: -30–160°C.Max. percentage of glycol: 50%.Oversized discharge outlet.Discharge rating: 1/2” - 50 kW.

3/4” - 100 kW.TÜV certified to SV100 7.7No. TÜV SV 07 2009 · SOL · H · p.Settings: 2,5 - 3 - 4 - 6 - 8 - 10 bar.

Code

11

15

250300250400

3/8” M x 3/8” F - batterfly handle1/2” M x 1/2” F - lever handle

250 tech. broch. 01133

Shut-off cock complete with seal.Brass body. Chrome plated.Max. working pressure: 10 bar.Temperature range: -30–200°C.Max. percentage of glycol: 50%.

Code

251905251906

3/4” F1” F

251 tech. broch. 01134

DISCAL®

Deaerator for vertical pipes, for solar thermal systems.Brass body. Chrome plated.Female connections.Max. working pressure: 10 bar.Max. discharge pressure: 10 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.

Code

The automatic air vent must be shut off afterthe system has been filled.

3

251093 3/4” F

Code

251 tech. broch. 01197

Manual air separator.Brass body.Female connections.Max. working pressure: 10 bar.Max. discharge pressure: 10 bar.Temperature range: -30÷200°C.Max. percentage of glycol: 50%.

Page 4: Caleffi International NV - Brochure Solar

267Pump station for solar thermal systems, flow and return connection,with solar controller.Supply: 230 V (ac).Max. working pressure: 10 bar.Safety relief valve temperature range: -30–160°C.Safety relief valve setting: 6 bar(for other setting, see 253 series using the adaptercode F21224).Balancing valve with flow meter temperaturerange: -30–130°C.Max. percentage of glycol: 50%.

Consisting of:- Solar 15-80 circulation pump;- safety relief valve for solar thermal systems 253 series;- 2 fill/drain cocks;- instrument holder fitting with pressure gauge;- balancing valve with graduated scale flow meterwith magnetic movement flow rate indicator;- deaerator device;- flow temperature gauge;- return temperature gauge;- 2 shut-off valves and check valve;- pre-formed shell insulation;

- digital controller DeltaSol® C+ with probes.

267Pump station for solar thermal systems, flow and return connection.Supply: 230 V (ac).Max. working pressure: 10 bar.Safety relief valve temperature range: -30–160°C.Safety relief valve setting: 6 bar(for other setting, see 253 series using the adaptercode F21224).Balancing valve with flow meter temperaturerange: -30–130°C.Max. percentage of glycol: 50%.

Consisting of:- Solar 15-80 circulation pump;- safety relief valve for solar thermal systems 253 series;- 2 fill/drain cocks;- instrument holder fitting with pressure gauge;- balancing valve with graduated scale flow meterwith magnetic movement flow rate indicator;- deaerator device;- flow temperature gauge;- return temperature gauge;- 2 shut-off valves and check valve;- pre-formed shell insulation.

PUMP STATIONS

267250267254267252

3/4” F3/4” F3/4” F

2–17 3–107–25

Flow meter scale(l/min)Code

267050267054267052

3/4” F3/4” F3/4” F

2–17 3–107–25

Flow meter scale(l/min)Code

4

Page 5: Caleffi International NV - Brochure Solar

PUMP STATIONS

266250266254266252

3/4” F3/4” F3/4” F

2–17 3–107–25

Flow meter scale(l/min)Code

266050266054266052

3/4” F3/4” F3/4” F

2–17 3–107–25

Flow meter scale(l/min)Code

266Pump station for solar thermal systems, return connection,with solar controller.Supply: 230 V (ac).Max. working pressure: 10 bar.Safety relief valve temperature range: -30–160°C.Safety relief valve setting: 6 bar(for other setting, see 253 series using the adaptercode F21224).Balancing valve with flow meter temperaturerange: -30–130°C.Max. percentage of glycol: 50%.

Consisting of:- Solar 15-80 circulation pump;- safety relief valve for solar thermal systems 253 series;- 2 fill/drain cocks;- instrument holder fitting with pressure gauge;- balancing valve with graduated scale flow meterwith magnetic movement flow rate indicator;- return temperature gauge;- shut-off valves and check valve;- pre-formed shell insulation;

- digital controller DeltaSol® C+ with probes.

266Pump station for solar thermal systems, return connection.Supply: 230 V (ac).Max. working pressure: 10 bar.Safety relief valve temperature range: -30–160°C.Safety relief valve setting: 6 bar(for other setting, see 253 series using the adaptercode F21224).Balancing valve with flow meter temperaturerange: -30–130°C.Max. percentage of glycol: 50%.

Consisting of:- Solar 15-80 circulation pump;- safety relief valve for solar thermal systems 253 series;- 2 fill/drain cocks;- instrument holder fitting with pressure gauge;- balancing valve with graduated scale flow meterwith magnetic movement flow rate indicator;- return temperature gauge;- shut-off valves and check valve;- pre-formed shell insulation.

5

Page 6: Caleffi International NV - Brochure Solar

269Pump station for solar thermal systems, flow and return connection, with solar controller.Supply: 230 V (ac).Max. working pressure: 10 bar.Safety relief valve temperature range: -30–160°C.Safety relief valve setting: 6 bar(for other setting, see 253 series).Flow meter temperature range: -10–110°C.Max. percentage of glycol: 50%.

Consisting of:- Solar 15-65 circulation pump;- safety relief valve for solar thermal systems 253 series;- 2 fill/drain cocks;- instrument holder fitting with pressure gauge;- flow meter;- deaerator device;- flow temperature gauge;- return temperature gauge;- 2 shut-off valves and check valve;- 2 hose connections;- pre-formed shell insulation;

- digital controller DeltaSol® C+ with probes.

269Pump station for solar thermal systems, flow and return connection.Supply: 230 V (ac).Max. working pressure: 10 bar.Safety relief valve temperature range: -30–160°C.Safety relief valve setting: 6 bar(for other setting, see 253 series).Flow meter temperature range: -10–110°C.Max. percentage of glycol: 50%.

Consisting of:- Solar 15-65 circulation pump;- safety relief valve for solar thermal systems 253 series;- 2 fill/drain cocks;- instrument holder fitting with pressure gauge;- flow meter;- deaerator device;- flow temperature gauge;- return temperature gauge;- 2 shut-off valves and check valve;- 2 hose connections;- pre-formed shell insulation.

PUMP STATIONS

269250 3/4” F 1–13

Flow meter scale(l/min)Code

269050 3/4” F 1–13

Flow meter scale(l/min)Code

6

Page 7: Caleffi International NV - Brochure Solar

PUMP STATIONS

268250 3/4” F 1–13

Flow meter scale(l/min)Code

268050 3/4” F 1–13

Flow meter scale(l/min)Code

268Pump station for solar thermal systems, return connection, with solar controller.Supply: 230 V (ac).Max. working pressure: 10 bar.Safety relief valve temperature range: -30–160°C.Safety relief valve setting: 6 bar(for other setting, see 253 series).Flow meter temperature range: -10–110°C.Max. percentage of glycol: 50%.

Consisting of:- Solar 15-65 circulation pump;- safety relief valve for solar thermal systems 253 series;- fill/drain cock;- instrument holder fitting with pressure gauge;- flow meter;- return temperature gauge;- shut-off valve and check valve;- 2 hose connections;- pre-formed shell insulation;

- digital controller DeltaSol® C+ with probes.

268Pump station for solar thermal systems, return connection.Supply: 230 V (ac).Max. working pressure: 10 bar.Safety relief valve temperature range: -30–160°C.Safety relief valve setting: 6 bar(for other setting, see 253 series).Flow meter temperature range: -10–110°C.Max. percentage of glycol: 50%.

Consisting of:- Solar 15-65 circulation pump;- safety relief valve for solar thermal systems 253 series;- fill/drain cock;- instrument holder fitting with pressure gauge;- flow meter;- return temperature gauge;- shut-off valve and check valve;- 2 hose connections;- pre-formed shell insulation.

7

Page 8: Caleffi International NV - Brochure Solar

259 tech. broch. 01136

Welded expansion vessel only for primarycircuit of solar thermal systems.Diaphragm certified to DIN 4807-3 standard.Max. working pressure: 10 bar.Diaphragm max. temperature: 100°C. System temperature range: -10–120°C.Max. percentage of glycol: 50%.

259012259018259024259035259050

3/4”3/4”3/4”3/4”3/4”

1218243550

Code Litres Conn.

2,52,52,52,52,5

Precharge(bar)

255010

255System filling pump for pump stations 266 and 267 series.

Code

ACCESSORIES FOR PUMP STATIONS

Adapter for pump stations 266 and 267 series.To be used with safety relief valve 253 series, 1/2”.

F21224

Code

240 tech. broch. 01185

Ball valve for solar thermal system.Body and ball in stainless steel AISI 316.

PN 63.Female connections.Handle in stainless steel AISI 304.Temperature range: -30–200°C.Max. percentage of glycol: 50%.

BALL VALVE AND THREE-PIECE UNION FITTING

588052588062

3/4” F x M with union1” F x M with union

588Three-piece straight union fitting for solar thermal systems.Max. working pressure: 16 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.Black nickel plated nut.

Code

240400240500240600

Code

1/2”3/4”1”

8

255 tech. broch. 01136

Expansion vessel connection kit.Consisting of:- stainless steel flexible hose (L=500 mm); - automatic shut-off cock;- wall mounting bracket (for vessels up to 24 litres).

Max. working pressure: 10 bar.Shut-off cock max. working temperature:110°C.Max. percentage of glycol: 50%.

255001 3/4”

Code

Page 9: Caleffi International NV - Brochure Solar

BALANCING VALVE WITH FLOW METER

258 tech. broch. 01148

Balancing valve with flow meter, for solar thermal systems. Direct reading of flow rate.Brass valve body and flow meter.Chrome plated.Ball valve for flow rate adjustment.Graduated scale flow meter with magneticmovement flow rate indicator.

With insulation.Max. working pressure: 10 bar.Temperature range: -30–130°C.Max. percentage of glycol: 50%.Patent application No. MI2007A000703.

3/4”3/4”3/4”1”

258503258533258523258603

Code

12–0713–1017–2810–40

Flow rate range(l/min)

1/2”3/4”1”

Conn.

755254755255755256

Code

1,52,53,5

Qnom m3/h

single jet

single jet

multi jet

Meas. type

HEAT METER

75525 CONTECA tech. broch. 01146

Direct heat metering with local LCD reading by means orcentralised reading with controller code 755010 or interfacecode 755055, for solar thermal systems.

Max. working pressure: 10 bar.Temperature range: 5–120°C.Max. percentage of glycol: 50%.

The CONTECA module is supplied complete with:- Pair of temperature probes with immersion pockets.- Y pockets for immersion probes. - Water meter, with pulse output (max. temperature 120°C).- Electronic integrator with LCD.- Supply 24 V (ac) 50 Hz - 1 W. - Set for transmission in RS485 Bus mode. Conformity to EN 1434-1.

9

Page 10: Caleffi International NV - Brochure Solar

10

DIGITAL CONTROLLER

257041

257SOLCAL® 1Digital controller for solar thermal systems.Complete with wall mounting basis for plug-in electrical connection.Complete with three probes type Pt1000.Double relays output.Supply: 230 V ±6% - 50 Hz.Power consumption: 4 VA.Max. contact rating: 250 V (ac) - 8 (2) A.Protection class: IP 40.

Code

Characteristic components

Regulation programsThe controller allows to manage 11 regulation programs,depending on the possible system configurations. They can beused for systems with single or double storage, swimming-pools,heating or domestic water systems, etc..

257Pocket for Pt1000 probe.In steel.Lenght: 100 mm.

257004

Code

90 x 136 x 80 1/2”

(h x w x d)

11) LED 1: function error or probe fault (red) 12) LED 2: Solar circuit pump ON13) LED 3: second relays output active14) LED 4: OFF regulator non active15) LED 5: ON regulator active16) LED 6: active relays test17) Storage temperature control setting at level 1,

at level 2 depending on programme (see system)18) ∆T min. and max. control19) Min. temperature control for solar panel activation

and min. working time10) Operation button

Page 11: Caleffi International NV - Brochure Solar

DIFFERENTIAL REGULATORS AND THERMOSTAT

257000

257 tech. broch. 01143

Differential temperature regulator for solarthermal systems, with relays output.Box protection class: IP 65.Supply: 230 V ±6% - 50 Hz.Nominal power consumption: 1,45 VA.Contact rating on switch-over: 6 A (230 V).∆T adjustment range: 2–20 K.Hysteresis: 2 K (±1 K).

Code

257002

257 tech. broch. 01143

Thermostat for solar thermal systems, with relays output. For thermal integrationcontrol and diverter valves.Box protection class: IP 65.Supply: 230 V ±6% - 50 Hz.Nominal power consumption: 1,45 VA.Contact rating on switch-over: 6 A (230 V).Adjustment temperature range: 20–90°C.Hysteresis: 1 K.

Code

257010

257 tech. broch. 01143

Differential temperature regulator for solarthermal systems, with relays output.Complete with contact probe and immersion probe with pocket.Box protection class: IP 65.Supply: 230 V ±6% - 50 Hz.Nominal power consumption: 1,45 VA.Contact rating on switch-over: 6 A (230 V).∆T adjustment range: 2–20 K.Hysteresis: 2 K (±1 K).

Code

257001

257 tech. broch. 01143

Box complete with DIN bar,for regulator or thermostat 257 series. Protection class: IP 65.

Code

257003

257 tech. broch. 01143

Double box complete with DIN bar,for regulator and thermostat 257 series. Protection class: IP 65.

Code

150 tech. broch. 01143

Contact probe for regulator or thermostat 257 series and for regulator 1520 series(flow or return).Cable lenght: 2 m.

150 tech. broch. 01143

Immersion probe for regulator or thermostat 257 series and for regulator 1520 series.Cable lenght: 2 m.

150009

Code

150006

Code

150 tech. broch. 01143

Pocket for immersion probe code 150006.

150029 1/4” M

Code

200 x 122 x 112

(h x w x d)

200 x 160 x 112

(h x w x d)

11

Page 12: Caleffi International NV - Brochure Solar

12

254305254308254302

Code

Ø 15Ø 18Ø 22

2545Elbow coupling sleeve, mechanical O-Ring seal for solar thermal systems. For annealed copper, hard copper,brass, mild and stainless steel pipes.Max. working pressure: 16 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.Black nickel plated nut.

254505254508254502

Code

Ø 15Ø 18Ø 22

2544Male fitting, mechanical O-Ring seal for solar thermal systems. For annealed copper, hard copper, brass, mild and stainless steel pipes.Max. working pressure: 16 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.Black nickel plated nut.

254455254458254452254465254462

Code

3/4” M - Ø 153/4” M - Ø 183/4” M - Ø 221” M - Ø 151” M - Ø 22

2547Male elbow fitting, mechanical O-Ring seal for solar thermal systems. For annealed copper, hard copper,brass, mild and stainless steel pipes.Max. working pressure: 16 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.Black nickel plated nut.

254755254758254752

Code

3/4” M - Ø 153/4” M - Ø 183/4” M - Ø 22

2548Female elbow fitting, mechanical O-Ring seal for solar thermal systems. For annealed copper, hard copper,brass, mild and stainless steel pipes.Max. working pressure: 16 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.Black nickel plated nut.

254855254858254852

Code

3/4” F - Ø 153/4” F - Ø 183/4” F - Ø 22

FITTINGS

2543Coupling sleeve, mechanical O-Ring sealfor solar thermal systems. For annealed copper, hard copper, brass, mild and stainless steel pipes.Max. working pressure: 16 bar.

Temperature range: -30–160°C.Max. percentage of glycol: 50%.Black nickel plated nut.

2540Female fitting, mechanical O-Ring sealfor solar thermal systems. For annealed copper, hard copper, brass, mild and stainless steel pipes.Max. working pressure: 16 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.Black nickel plated nut.

254055254058254052254062254068

Code

3/4” F - Ø 153/4” F - Ø 183/4” F - Ø 221” F - Ø 221” F - Ø 28

Ø 22254002

2540Plug for Ø 22 copper pipe.

Code

2546Tee fitting,mechanical O-Ring seal for solar thermal systems.

For annealed copper, hard copper, brass, mild and stainless steel pipes.Max. working pressure: 16 bar.Temperature range: -30–160°C.Max. percentage of glycol: 50%.Black nickel plated nut.

254505254508254502

Code

Ø 15Ø 18Ø 22

Page 13: Caleffi International NV - Brochure Solar

COMPONENTS FOR SECONDARY CIRCUIT

Normally closedvalve

Diverter on thesecondary circuit

SOLARSTORAGE

13

Page 14: Caleffi International NV - Brochure Solar

THERMOSTATIC MIXING VALVE

ANTI-SCALD THERMOSTATIC MIXING VALVE

2527 tech. broch. 01165

Anti-scald adjustable thermostaticmixing valve, with check valves andstrainers, for solar thermal systems. High thermal performance device,with anti-scald safety function.

dezincification resistant alloy body.Chrome plated.Male union connections.Performance to standards NF 079 Doc. 8,EN 15092, EN 1111, EN 1287.Max. working pressure: 10 bar.Max. inlet temperature: 100°C.

Code

252714252713

1/2”3/4”

35–55°C35–55°C

1,51,7

Kv (m3/h)Temperatureadjustment

252140252150

2521 tech. broch. 01127

Adjustable thermostatic mixing valvefor solar thermal systems.

dezincification resistant alloy body.Chrome plated.Male union connections.Max. working pressure: 14 bar.Max. inlet temperature: 100°C.

Code

1/2”3/4”

30–65°C30–65°C

2,62,6

Kv (m3/h)Temperatureadjustment

252153

2521 tech. broch. 01127

Adjustable thermostatic mixing valve, with check valves, for solar thermal systems.

dezincification resistant alloy body.Chrome plated.Male union connections.Max. working pressure: 14 bar.Max. inlet temperature: 100°C.

Code

3/4” 30 –65°C 2,6

Kv (m3/h)Temperatureadjustment

252340252350252360252370252380252390

Code

1/2”3/4”1”1 1/4”1 1/2”2”

1/2” - 3/4”

30–65°C30–65°C30–65°C30–65°C35–65°C35–65°C

14,014,516,919,114,519,0

Kv (m3/h)Temperatureadjustment

2523 tech. broch. 01129

Thermostatic mixing valve withinterchangeable cartridge for solar thermal systems.

Brass body. Chrome plated.Male union connections.Max. working pressure: 14 bar.Max. inlet temperature: 110°C.

252305

2523Spare cartridge.For thermostatic mixing valve 2523 series.

Code

2523Spare cartridge.For thermostatic mixing valve 2523 series.

1” - 1 1/4”1 1/2” - 2”

252306252308

Code

14

Page 15: Caleffi International NV - Brochure Solar

MOTORISED BALL DIVERTERVALVE

6443 tech. broch. 01132

Motorised three-way ball diverter valve.Max. working pressure: 10 bar.Max. ∆p: 10 bar.Temperature range: -5–110°C.

Complete with actuator with 3-contact control.With auxiliary microswitch.Electric supply: 230 V (ac).Power consumption: 8 VA.Auxiliary microswitch contact rating: 0,8 A (230 V).Ambient temperature range: 0–55°C.

Protection class: IP 44 (vertical stem).IP 40 (horizontal stem).Operating time: 10 s (90° rotation). Cable lenght: 100 cm.Patent application No. MI2005A001282.

644346644356644357644366

1/2”3/4”3/4”1”

230230230230

3,93,98,69,0

Code Kv (m3/h)Electric supply

V

309461309471309401309561309571309501

1/2” M x Ø 15 6 bar1/2” M x Ø 15 7 bar1/2” M x Ø 15 10 bar3/4” M x Ø 22 6 bar3/4” M x Ø 22 7 bar3/4” M x Ø 22 10 bar

Code

TEMPERATURE AND PRESSURERELIEF VALVE

309 tech. broch. 01147

Temperature and pressure relief valve.For solar thermal systems, for protecting the hot water storage.

dezincification resistant alloy body. Chrome plated.Set temperature: 90°C.Discharge rating: 1/2” x Ø 15: 10 kW.

3/4” x Ø 22: 25 kW.Settings: 6 - 7 - 10 bar.Settings certified to EN 1490: 7 - 10 bar.

11

15

15

Page 16: Caleffi International NV - Brochure Solar

SOLAR STORAGE-BOILER CONNECTION KIT

a aa a a aa a aaApplication diagram of SOLARNOCAL kit 264 series

Hydraulic diagrams

M D

BOILER

USERSOLAR

TSOLAR > 45°C

M D

BOILER

USERSOLAR

TSOLAR < 45°C

COLDCOLD

MIX

264352

Code

3/4”

264 tech. broch. 01163

SOLARNOCAL

Function

A thermostatic anti-scald mixing valve, at the kit inlet, controls thetemperature of the water coming from the solar hot water storage.The thermostat, by means of the probe positioned on the hot waterflow from the solar hot water storage, controls the diverter valve atthe kit outlet. Depending on the temperature setting, the valvediverts the water towards the user circuit or activates the boilercircuit, without thermal integration.

Solar storage-boiler connection kit, without thermal integration.Consisting of:- thermostatic anti-scald mixing valve, adjustable with knob, for solar thermal systems. Complete with strainers and check valves at the inlets;

- diverter valve with three-contact actuator, with auxiliary microswitch;- thermostat with probe for solar thermal system, for operating diverter valve. Display showing temperature.

- pre-formed shell protective cover.

Diverter-mixing valve coupling with adjustable position of theinlet and outlet connections.

Mixing valvedezincification resistant alloy body. Chrome plated.

Max. working pressure: 10 bar.Adjustment temperature range: 35–55°C.Max. inlet temperature: 100°C.

Diverter valveBrass body. Chrome plated.Max. working pressure: 10 bar.Temperature range: -5–110°C.

ActuatorThree-contact type.Supply: 230 V (ac).Power consumption: 8 VA.Auxiliary microswitch contact rating: 0,8 A (230 V).Ambient temperature range: 0–55°C.Protection class: IP 44 (vertical stem).

IP 40 (horizontal stem).Operating time: 10 s.Cable lenght: 1 m.

Thermostat with probeSupply: 230 V (ac).Adjustable temperature range: 25–50°C.Factory setting: 45°C. Box protection class: IP 54.

Patent application No. MI2007A000936.

16

Page 17: Caleffi International NV - Brochure Solar

SOLAR STORAGE-BOILER CONNECTION KIT

265 tech. broch. 01163

SOLARINCAL

Function

The thermostat, by means of the probe positioned on the hot waterflow from the solar hot water storage, controls the diverter valve atthe kit inlet. Depending on the temperature setting, the valve divertsthe water towards the user circuit or the boiler circuit, with thermalintegration.A thermostatic anti-scald mixing valve, at the kit outlet, constantlycontrols the temperature of the water sent to the user.a aa a aa aaaApplication diagram of SOLARINCAL kit 265 series

Solar storage-boiler connection kit, with thermal integration.Consisting of:- thermostatic anti-scald mixing valve, adjustable with knob, for solarcthermal systems. Complete with strainers and check valves at the inlets;

- diverter valve with three-contact actuator, with auxiliary microswitch;- thermostat with probe for solar thermal system, for operatingdiverter valve. Display showing temperature.

- pre-formed shell protective cover.

Diverter-mixing valve coupling with adjustable position of theinlet and outlet connections.

Mixing valveFor technical details see 264 series.

Diverter valveFor technical details see 264 series.

ActuatorFor technical details see 264 series.

Thermostat with probeSupply: 230 V (ac).Adjustable temperature range: 25–50°C.Factory setting: 45°C.Box protection class: IP 54.

Patent application No. MI2007A000936.

MD

BOILER

SOLAR

TSOLAR > 45°C

MIXED

COLDM

D

BOILER

SOLAR

TSOLAR < 45°C

MIXED

COLD

265352

Code

3/4”

Hydraulic diagrams

265001

Code

264359265359F29525F29488257004

Code

kit 264 series without thermostat and probe

kit 265 series without thermostat and probe

box with switching 3 contact relay

Ø 6 mm probe

pocket probe

265Thermostat with display showing storage temperature.For devices 264 and 265 series.Supply: 230 V (ac).Adjustable temperature range: 25–50°C.Factory setting: 45°C.Box protection class: IP 54.

ACCESSORIES

17

Page 18: Caleffi International NV - Brochure Solar

SOLAR STORAGE-BOILER THERMOSTATIC CONNECTION KIT

COLDMIXED COLD

WATERINLET

a aa a aa aaApplication diagram of SOLARINCAL-T serie 262

262350

Code

3/4”

262 tech. broch. 01164

SOLARINCAL-T

Function

A thermostatic diverter valve, at the kit inlet, receives hot watercoming from the solar water storage.Depending on the temperature setting, the valve diverts the waterautomatically and in a proportional manner towards the user circuitor the boiler with storage circuit, with thermal integration.The valve modulates the flow rates to optimise the energycontained in the solar storage and reduce boiler operation times toa minimum.A thermostatic anti-scald mixing valve, at the kit outlet, constantlycontrols and limits the temperature of the water sent to the user.

Solar storage-boiler connection kit, with thermal integration.Consisting of:- thermostatic anti-scald mixing valve, adjustable with knob, for solar thermal systems. Complete with strainers and check valves at the inlets.

- thermostatic diverter valve;- pre-formed shell protective cover.

Diverter-mixing valve coupling with adjustable position of theinlet and outlet connections.

Mixing valvedezincification resistant alloy body. Chrome plated.

Max. working pressure: 10 bar.Adjustment temperature range: 35–55°C.Max. inlet temperature: 100°C.Performance to standards NF 079 doc. 8, EN 15092, EN 1111, EN 1287.

Diverter valveBrass body. Chrome plated.Max. working pressure: 10 bar.Factory setting: 45°C.Max. inlet temperature: 100°C.

Hydraulic diagrams

TSOLAR > 45°C TSOLAR < 45°C

M

BOILER

SOLARMIXED

COLD

M

BOILER

SOLARMIXED

COLD

DD

18

Page 19: Caleffi International NV - Brochure Solar

SOLAR STORAGE-BOILER THERMOSTATIC CONNECTION KIT

aa aa aaCOLDMIXED COLD

WATERINLET

MODULATINGBOILER

INGRESSOFREDDAFREDDA

MISCELATA

Valvola normalmente chiusa

Application diagram of SOLARINCAL-T Plus kit 263 series

263 tech. broch. 01164

SOLARINCAL-T PPLLUUSS

Function

A thermostatic diverter valve, at the kit inlet, receives hot watercoming from the solar water storage. Depending on thetemperature setting, the valve diverts the water automatically andproportionally towards the user circuit or the instantaneous boilercircuit, with thermal integration. The valve modulates the flowrates to optimise the energy contained in the solar storage andreduce boiler operation times to a minimum. A specific thermostatic control device limits the boiler inlettemperature to prevent it being switched on and off too often, whichleads to hunting and irregular operation. A thermostatic anti-scald mixing valve, at the kit outlet, constantlycontrols the temperature of the water sent to the user.

Solar storage-boiler connection kit, with thermal integration.Consisting of:- thermostatic anti-scald mixing valve, adjustable with knob, for solar thermal systems. Complete with strainers and check valves at the inlets;

- thermostatic diverter valve;- thermostatic control device;- pre-formed shell protective cover.

Mixing valvedezincification resistant alloy body. Chrome plated.

Max. working pressure: 10 bar.Adjustment temperature range: 35–55°C.Max. inlet temperature: 100°C.Performance to standards NF 079 doc. 8, EN 15092, EN 1111, EN 1287.

Diverter valvedezincification resistant alloy body. Chrome plated.

Max. working pressure: 10 bar.Factory set: 45°C.Max. inlet temperature: 100°C.

Control devicedezincification resistant alloy body. Chrome plated.

Factory setting: 30°C.Max. inlet temperature: 85°C.

Patent application No. MI2008A001813.

263350

Code

3/4”

Hydraulic diagrams

TSOLAR > 45°C TSOLAR < 45°C

M

BOILER

SOLARMIXED

COLD

M

BOILER

SOLARMIXED

COLD

D DC C

19

Page 20: Caleffi International NV - Brochure Solar

0311711G

B

Caleffi S.p.A. S.R. 229 n. 25 28010 Fontaneto D’Agogna (NO) Italy Tel. +39 0322 8491 Fax +39 0322 863723

· www.caleffi.com · [email protected] ·

© Copyright 2011 Caleffi