33
Pruebas y Ajustes 320D, 321D, 323D, 324D, 325D, 328D and 330D Excavators Tool Control System System 3: Solenoid Valve (Proportional Reducing) - Calibrate - Negative Flow Control SMCS - 5467-524-JV S/N - AZP1-UP S/N - SCR1-UP S/N - MEY1-UP S/N - NAS1-UP S/N - DHK1-UP S/N - PAL1-UP S/N - JJG1-UP S/N - B6H1-UP S/N - GTN1-UP S/N - JLP1-UP S/N - MWP1-UP S/N - KGF1-UP S/N - FXK1-UP S/N - XCK1-UP S/N - ZGB1-UP S/N - NBD1-UP S/N - WFD1-UP Cerrar SIS Pantalla anterior Producto: NO SE HA ESCOGIDO NINGUN EQUIPO Modelo: NO SE HA ESCOGIDO NINGUN EQUIPO Configuración: NO SE HA ESCOGIDO NINGUN EQUIPO Número de medio -RENR7389-09 Fecha de publicación -01/07/2007 Fecha de actualización -19/07/2007 i02590648 Página 1 de 33 Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and 33... 24/10/2007 https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...
Transcript
Page 1: Calibracion NFC Con PRV (2007)

Pruebas y Ajustes 320D, 321D, 323D, 324D, 325D, 328D and 330D Excavators Tool Control System

System 3: Solenoid Valve (Proportional Reducing) - Calibrate -Negative Flow Control SMCS - 5467-524-JV S/N - AZP1-UP S/N - SCR1-UP S/N - MEY1-UP S/N - NAS1-UP S/N - DHK1-UP S/N - PAL1-UP S/N - JJG1-UP S/N - B6H1-UP S/N - GTN1-UP S/N - JLP1-UP S/N - MWP1-UP S/N - KGF1-UP S/N - FXK1-UP S/N - XCK1-UP S/N - ZGB1-UP S/N - NBD1-UP S/N - WFD1-UP

Cerrar SIS

Pantalla anterior

Producto: NO SE HA ESCOGIDO NINGUN EQUIPO Modelo: NO SE HA ESCOGIDO NINGUN EQUIPO Configuración: NO SE HA ESCOGIDO NINGUN EQUIPO

Número de medio -RENR7389-09 Fecha de publicación -01/07/2007 Fecha de actualización -19/07/2007

i02590648

Página 1 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and 33...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 2: Calibracion NFC Con PRV (2007)

S/N - MCH1-UP S/N - FAL1-UP S/N - EDX1-UP S/N - PHX1-UP S/N - LAB1-UP S/N - A3R1-UP

This calibration procedure is used in order to record the calibration data from the proportional solenoid valve for the negative flow control. This calibration should be done at the following times: replacement of the NFC solenoid valve, replacement of the ECM, flash new software and adjustments to the horsepower controls on the pump.

Before this procedure is performed, ensure that the following requirements are met:

Verify that the engine speed is properly calibrated. If necessary, see Testing and Adjusting, "Calibration" for the Machine Electronic Control System.

Verify that the pilot pressure is set to the proper specification that is found in Testing and Adjusting, "Relief Valve (Pilot) - Test and Adjust" for the machine.

Verify that the main relief valve is set to the proper specification that is found in Testing and Adjusting, "Relief Valve (Main) - Test and Adjust" for the machine.

Verify that the power shift pressure is properly calibrated. If necessary, see Testing and Adjusting, "Calibration" for the Machine Electronic Control System.

There are two methods for calibrating the proportional solenoid valve for negative flow control. One method uses a flow meter and a pressure gauge. This method is more accurate. The other method uses only a pressure gauge. This method is less accurate. Both methods are described below.

Note: The less accurate method which uses only a pressure gauge is used only when a flow meter is not available.

Página 2 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and 33...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 3: Calibracion NFC Con PRV (2007)

The device for activation of the work tool is the thumb wheel on the right joystick.

Calibration with a Pressure Gauge and a Flow Meter Note: When additional safety is needed on machines that are equipped with a swing brake solenoid, disconnect the swing brake solenoid so that the swing brake remains engaged.

1. Position the machine on level ground and stop the engine.

2. Release the pressure in the hydraulic system. Refer to Testing and Adjusting, "Hydraulic System Pressure - Release" for the machine.

3. Install a 400 L (80 US gal) flow meter in the hydraulic line to the tool.

Note: Table 2 lists the parts which appear in Illustration 2.

Illustration 1 g01154622Thumb wheel on the right joystick

Table 1

TOOL CHART FOR FLOW TEST

Item Number Part Number Part Description Quantity

Página 3 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and 33...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 4: Calibracion NFC Con PRV (2007)

10 4C-9910 Flow Meter 1

11 6K-6307 O-ring seal 2

12 8C-9026 Adapter 2

13 7M-8485 O-ring seal 8

14 4C-6482 Nipple 4

9U-5086 Optional Dust Cap 4

15 4C-6481 Coupler 4

9U-5084 Optional Dust Plug 4

16 4C-8767 Coupling 4

17 5P-1010 Sleeve 4

18 5P-0201 XT-5 Hose 3.5 m (12 ft)

2

19 8T-3194 Hex Bolt 4

20 8T-4223 Hard Washer 2

21 1P-5767 Half Flange 4

22 9U-7440 Adapter 2

23 1P-3704 Rectangular Seal 2

28 6V-4143 Coupler 2

29 6V-3014 Hose 1

30 6V-3989 Nipple 1

31 8T-0861 Pressure Gauge 1

Página 4 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and 33...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 5: Calibracion NFC Con PRV (2007)

Illustration 2

(24) Port on supply line for work tool

(25) Port on return line for work tool

(26) Pump pressure tap

Página 5 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and 33...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 6: Calibracion NFC Con PRV (2007)

a. Connect one end of the test hose (32) to the supply line for the work tool (24) . Connect the other end of the test hose (32) to the inlet port on the flow meter (40) . Refer to Illustration 3.

b. Connect one end of the second test hose (33) to the return line for the work tool. Connect the other end of the test hose (33) to the outlet port on the flow meter. Refer to Illustration 3.

(27) Pump pressure tap

(35) Main pump

Illustration 3 g01134699(10) Flow meter

(32) Test hose from the supply line for work tool

(33) Test hose to the return line for the work tool

(34) Load valve for flow meter

(40) Flow meter inlet

(41) Outlet of the flow meter

(42) Pressure gauge for the flow meter

Página 6 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and 33...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 7: Calibracion NFC Con PRV (2007)

Illustration 4 g01224607Pump Compartment 320D, 324D, 325D and 328D

(26) Pressure tap (idler pump pressure)

(27) Pressure tap (drive pump pressure)

(37) Pressure tap (power shift pressure)

Illustration 5 g01239824Pump Compartment 330D

(26) Pressure tap (idler pump pressure)

(27) Pressure tap (drive pump pressure)

Página 7 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and 33...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 8: Calibracion NFC Con PRV (2007)

4. Install a 40000 kPa (5800 psi) pressure gauge (31) on pressure tap (27) .

5. Place the backup switch in the AUTO position.

6. Start the engine.

7. Move the engine speed dial to position 10.

8. Increase the oil temperature to 50 °C (122 °F).

Two Pump Calibration

Use Illustration 6 in order to navigate the monitor.

(37) Pressure tap (power shift pressure)

Illustration 6 g01197980(1) Up key

(2) Right key

(3) Home key

(4) Main menu

(5) Left key

(6) Down key

(7) Cancel key

(8) OK key

Página 8 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and 33...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 9: Calibracion NFC Con PRV (2007)

1. Be sure to select a work tool that provides two pump flow. Refer to Testing and Adjusting, "Work Tool - Select" for the Tool Control System.

2. In order to access the "CALIBRATION" menu, you must first enter the "SERVICE" mode on the monitor.

3. Use the following procedure to access the "SERVICE" screen on the monitor.

a. From the default screen, press the main menu key (4) .

b. From the "MAIN MENU" screen, use the right key (2) to scroll through the menu options.

c. When the "SERVICE" option is highlighted, press the OK key (8) .

d. When "PASSWORD" screen appears, use the right key (2) and the left key (5) in order to scroll through the characters. When the desired character is highlighted, press the OK key (8) . Enter the password for service FFF2 in order to continue to the "SERVICE" screen.

e. After the password has been entered the "SERVICE" screen should appear. Refer to Illustration 7.

Note: For more detailed steps with entering passwords or entering the service mode, refer to Testing and Adjusting, "Service Mode - Enter" for the Tool Control System.

Página 9 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and 33...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 10: Calibracion NFC Con PRV (2007)

4. From the "SERVICE" menu, use the up key (1) or the down key (6) in order to move the highlighted line.

5. When the "CALIBRATIONS" menu option is highlighted, press the OK key (8) .

Illustration 7 g01199794Typical example of the "SERVICE" menu for the monitor

Página 10 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 11: Calibracion NFC Con PRV (2007)

6. After the OK key is pressed the "CALIBRATIONS" screen will appear. From the "CALIBRATIONS" menu, highlight "FLOW LIMIT VALVE".

7. When the "FLOW LIMIT VALVE" option is highlighted, press the OK key (8) .

Illustration 8 g01223994Typical example of the "CALIBRATIONS" screen

Página 11 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 12: Calibracion NFC Con PRV (2007)

8. After the OK key is pressed the "FLOW LIMIT VALVE" menu will appear. From this menu, the following options are available:

"FLOW LIMIT PRES"

"2PUMP FLOW LIMIT"

"1PUMP FLOW LIMIT"

9. From the "FLOW LIMIT VALVE" menu, highlight the "2PUMP FLOW LIMIT" option. When "2PUMP FLOW LIMIT" option is highlighted, press the OK key (8) .

Illustration 9 g01223996

Página 12 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 13: Calibracion NFC Con PRV (2007)

10. After the OK key is pressed, the "CALIBRATION TITLE" screen will appear. Refer to Illustration 10. The "CALIBRATION TITLE" screen allows the upper limitation and the lower limitation to be set.

Note: The title of the calibration and the name of the step will change in accordance to the procedure that is being performed. "CALIBRATION TITLE" and "STEP NAME" are used in this document as an example.

Illustration 10 g01200825"CALIBRATION TITLE" screen

(L) Lower limit

(U) Upper limit

(C) Current value

(S) "STEP No:"

Página 13 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 14: Calibracion NFC Con PRV (2007)

Note: In the "CALIBRATION TITLE" screen, "STEP No" is displayed in blue. The "OPERATIONAL GUIDANCE" will be displayed in green.

11. The following procedure describes calibration of the monitor.

a. Perform the "2PUMP FLOW -MAX" calibration first.

b. Press the device for activation 3 times and release the device for activation 3 times.

c. Press and hold the device for activation to the OPERATING position during calibration. Press the OK key (8) .

Note: Pressing the device for activation three times ensures that an accurate reading will result.

d. Adjust the setting of the load valve of the flow meter and observe pressure gauge (42) . Adjust the setting until the "INDICATED PRESSURE" from Table 3 is achieved.

Pump pressure is affected by the flow and the open rate of the load valve on the flow meter (34) . The load valve on the flow meter (34) must be adjusted when a change of calibration is made. When you adjust the calibration value and the open rate of the load valve on the flow meter (34) , always return the tool to the neutral position and repeat the calibration.

If the flow is not within the proper specifications, the machine must be adjusted. Proceed to Steps 11.e through 11.j.

e. Release the device for activation. DO NOT change the setting of the load valve on the flow meter.

f. Press the right key (2) in order to increase the value or press the left key (5) in order to decrease the value.

g. Press and release the device for activation 3 times.

h. Press and hold the device for activation.

i. If the "INDICATED PRESSURE", that is found in Table 3, is out of the proper range, adjust the load valve on the flow meter (34) until the pressure gauge (42) indicates the value in Table 3.

j. Refer to Table 3 and observe the flow meter in order to verify that the flow rate is within the proper specification.

k. Tune the flow to the "TARGET VALUE" that is located in Table 3.

l. Repeat Step 11.e through Step 11.k until the flow rate in Step 11.k is obtained with no adjustment of the monitor or the load valve for several repetitions.

Note: Hold the device for activation in the "OPERATION" position for a few seconds in order to allow the hydraulic system to stabilize before repeating the Steps.

m. When the reading is within the proper range, continue to hold the device for activation

Página 14 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 15: Calibracion NFC Con PRV (2007)

in the OPERATION position and press the OK key (8) in order to set the value.

Note: If OK key (8) is not pressed, the calibration will not be saved.

12. When the calibration for "MAX" flow is completed, calibrate "MIN" flow. Repeat Steps 11.b through 11.m for the "MIN" flow.

The "2PUMP FLOW" calibration is now complete. It is possible for an error to occur when you are calibrating. Table 4 gives some of the errors that may occur.

Table 2

ITEM FOR CALIBRATION DISPLAY

Use information that pertains to the calibration that is being performed.

TARGET VALUE

MEASUPOINT

PROPORTIONAL SOLENOID VALVE FOR NEGATIVE FLOW CONTROL

"SYSTEM 3, 14, 16, 17" Use the following information for calibration with only a pressure gauge.

NFC1 PRV

LOW PRESSURE

1450 to 1550 kPa (210 to 225 psi)

"Pncd" "Pnci" These pare prestaps forpump (2the prestap for Ipump (2

HIGH PRESSURE

2950 to 3050 kPa (428 to 442 psi)

"SYSTEM 3, 14, 16, 17" Use the highlighted information for calibration with a pressure gauge and a flow meter.

2 PUMP FLOW

MAX FLOW

220 ± 2 L/min (58 ± .5 US gpm)

FLOW METER

INDICATED PRESSURE

16000 kPa (2321 psi)

PRESS(42)

MIN FLOW

140 ± 2 L/min (37 ± 0.5 US gpm)

FLOW METER

INDICATED PRESSURE

16000 kPa (2321 psi)

PRESS(42)

Página 15 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 16: Calibracion NFC Con PRV (2007)

Table 3

Error Description of Event

$0001 ECM Fault

$0002 Active Diagnostic Present

$0003 Another Calibration is Active

$0004 Calibration Active by Another ECM

$0005 Loss of Calibration Interlock

$0006 Calibration Aborted by Tool/Monitor

$0007 Requested Display Not Supported

$0008 Unavailable Display

$0009 Calibration Aborted by ECM

$000A Calibration Failure

$000B Calibration Not Supported

$0100 Out-of-Range Low - Incr/Decr Parameter

$0101 Out-of-Range High - Incr/Decr Parameter

$0102 Invalid Action/Key Stroke Command

$0103 Calibration Value Out-of-Range

$0104 Calibration Range Too Small

$0105 Calibration Range Too Large

$0106 Calibration Value Not Saved

$1000 See Service Manual

$1010 Engine Stopped (No Engine RPM)

$1011 Engine Running (Engine RPM Present)

$1012 Engine RPM Incorrect

$1013 Engine High Idle RPM Too Fast

$1014 Engine Low Idle RPM Too Slow

$1015 Abnormal Engine RPM Signal

$1016 Speed Sensor Circuit Is Open

$1017 Service Brake Pedal Pressed

$1018 Parking Brake Not Engaged

Página 16 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 17: Calibracion NFC Con PRV (2007)

Calibration with a Pressure Gauge Note: There are two methods for calibrating the proportional solenoid valve for negative flow control. One method, which uses a flow meter and a pressure gauge, is more accurate. The method that is listed below uses only a pressure gauge. This method for calibrating the proportional solenoid valve is less accurate. This method should be used only when a flow meter is not available.

Note: When additional safety is needed on machines that are equipped with a swing brake solenoid, disconnect the swing brake solenoid so that the swing brake remains engaged.

1. Be sure to select a work tool that provides two pump flow. Refer to Testing and Adjusting, "Work Tool - Select" for the Tool Control System.

2. Position the machine on level ground and stop the engine.

3. Before the adjustment procedure begins, lower the work tool to the ground.

4. Close the stop valves that are mounted on each side of the stick in order to prevent oil flow to the work tool during this procedure.

5. Release the pressure in the hydraulic system. Refer to Testing and Adjusting, "Hydraulic System Pressure - Release" for the Tool Control System.

$1019 Parking Brake Engaged

$101A Implement is Swinging/Travelling

$101B Machine Speed Not Zero

Página 17 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 18: Calibracion NFC Con PRV (2007)

6. Attach a 4900 kPa (750 psi) pressure gauge to the pressure tap for the proportional solenoid valve for negative flow control (38) .

Illustration 11 g01224034(38) Pressure tap for the proportional solenoid valve for negative flow control

Página 18 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 19: Calibracion NFC Con PRV (2007)

7. Place the backup switch in the AUTO position. When AEC is active, the lamp above the auto switch will illuminate. Refer to Illustration 12.

8. Start the engine.

9. Move the engine speed dial to position 10.

10. Raise the oil temperature to 50° ± 5°C (122° F).

11. Verify that the pilot pressure is set to the specifications that are in Testing and Adjusting, "Relief Valve (Pilot) - Test and Adjust" for the machine.

12. Ensure that a "TOOL#" is selected.

13. Enter the "SERVICE" mode on the monitor. Use the following procedure to access the "SERVICE" mode.

Illustration 12 g01135136(A) Auto switch

Illustration 13 g01197980

Buttons for controlling the monitor

(1) Up key

(2) Right key

(3) Home key

(4) Main menu key

(5) Left key

Página 19 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 20: Calibracion NFC Con PRV (2007)

a. From the default screen, press the main menu key (4) .

b. From the "MAIN MENU" screen, use the right key (2) to scroll through the menu options.

c. When the "SERVICE" option is highlighted, press the OK key (8) .

d. When "PASSWORD" screen appears, use the right key (2) and the left key (5) in order to scroll through the characters. When the desired character is highlighted, press the OK key (8) . Enter the password for service FFF2 in order to continue to the "SERVICE" screen.

e. After the password has been entered the "SERVICE" screen should appear. Refer to Illustration 14.

(6) Down key

(7) Cancel key

(8) OK key

Página 20 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 21: Calibracion NFC Con PRV (2007)

14. From the "SERVICE" menu, use the up key (1) or the down key (6) in order to move the highlighted line.

15. When the "CALIBRATIONS" menu option is highlighted, press the OK key (8) .

Illustration 14 g01199794Typical example of the "SERVICE" menu for the monitor

Página 21 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 22: Calibracion NFC Con PRV (2007)

16. When the "FLOW LIMIT VALVE" option is highlighted, press the OK key (8) .

Illustration 15 g01223994

Página 22 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 23: Calibracion NFC Con PRV (2007)

17. After the OK key is pressed the "FLOW LIMIT VALVE" menu will appear. From this menu, the following options are available:

"FLOW LIMIT PRES"

"2PUMP FLOW LIMIT"

"1PUMP FLOW LIMIT"

Refer to Illustration 16.

18. From the "FLOW LIMIT VALVE" menu, highlight the "FLOW LIMIT PRES" option. When "FLOW LIMIT PRES" option is highlighted, press the OK key (8) .

Illustration 16 g01224194

Página 23 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 24: Calibracion NFC Con PRV (2007)

19. After the OK key is pressed, the "CALIBRATION TITLE" screen allows the upper limitation and the lower limitation to be set. Refer to Illustration 17.

Note: The title of the calibration and the name of the step will change in accordance to the procedure that is being performed. "CALIBRATION TITLE" and "STEP NAME" are used in this document as an example.

Illustration 17 g01200825"CALIBRATION TITLE" screen

(L) Lower limit

(U) Upper limit

(C) Current value

(S) "STEP No:"

Página 24 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 25: Calibracion NFC Con PRV (2007)

Note: In the "CALIBRATION TITLE" screen, "STEP No" is displayed in blue. The "OPERATION GUIDANCE" will be displayed in green. Perform the following operation for each "STEP No".

Illustration 18Illustration 18 displays the current value of pump 1 and pump 2.

Página 25 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 26: Calibracion NFC Con PRV (2007)

20. Operate the joystick to the STICK IN position. When the stick is in the STICK IN position, the hydraulic cylinder that controls the stick will be fully extended. Press the OK key (8) .

Illustration 19 g01224206

Página 26 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 27: Calibracion NFC Con PRV (2007)

21. After the OK key is pressed, resume operation of the joystick to the STICK IN position. Hold the stick in the STICK IN position during the calibration.

Illustration 20 g01224207

Página 27 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 28: Calibracion NFC Con PRV (2007)

22. While the stick is in the STICK IN position, activate the work tool. Observe the pressure on the gauge.

23. Use the left key (5) or the right key (2) to adjust the current level. Tune the machine to the "LOW PRESSURE" value that is located under "TARGET VALUE" that is found in table 3.

24. When the desired value is achieved, press the OK key (8) . The monitor will automatically begin the steps that are necessary to calibrate the "MAX" flow.

Illustration 21 g01224218

Página 28 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 29: Calibracion NFC Con PRV (2007)

25. Move the joystick to the STICK IN position. When the stick is in the STICK IN position, the hydraulic cylinder which controls the stick will be fully extended. Press the OK key (8) .

26. After the OK key is pressed, resume operation of the joystick to the STICK IN position. Hold the stick in the STICK IN position during the calibration.

Illustration 22 g01224223

Página 29 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 30: Calibracion NFC Con PRV (2007)

27. While the stick is in the STICK IN position, activate the work tool. Observe the pressure on the gauge.

28. Use the left key (5) or the right key (2) to adjust the current level. Tune the pressure to the "HIGH PRESSURE" value that is located under "TARGET VALUE" that is found in Table 3.

Illustration 23 g01224225

Página 30 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 31: Calibracion NFC Con PRV (2007)

29. When the desired value is achieved, press the OK key (8) . After the OK key is pressed, the monitor will automatically display the "SUCCEEDED" screen.

30. After completion of the calibration, press the cancel key (7) in order to exit the program.

31. It is possible for an error to occur during the calibration of the monitor. In case an error occurs, a screen with active errors will appear. If an screen of errors should appear, the calibration will fail and any set values that were achieved will be lost. Recalibrate the monitor. Refer to Table 5 for examples of possible errors.

Illustration 24 g01224227

Table 4

Error Description of Event

$0001 ECM Fault

Página 31 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 32: Calibracion NFC Con PRV (2007)

$0002 Active Diagnostic Present

$0003 Another Calibration is Active

$0004 Calibration Active by Another ECM

$0005 Loss of Calibration Interlock

$0006 Calibration Aborted by Tool/Monitor

$0007 Requested Display Not Supported

$0008 Unavailable Display

$0009 Calibration Aborted by ECM

$000A Calibration Failure

$000B Calibration Not Supported

$0100 Out-of-Range Low - Incr/Decr Parameter

$0101 Out-of-Range High - Incr/Decr Parameter

$0102 Invalid Action/Key Stroke Command

$0103 Calibration Value Out-of-Range

$0104 Calibration Range Too Small

$0105 Calibration Range Too Large

$0106 Calibration Value Not Saved

$1000 See Service Manual

$1010 Engine Stopped (No Engine RPM)

$1011 Engine Running (Engine RPM Present)

$1012 Engine RPM Incorrect

$1013 Engine High Idle RPM Too Fast

$1014 Engine Low Idle RPM Too Slow

$1015 Abnormal Engine RPM Signal

$1016 Speed Sensor Circuit Is Open

$1017 Service Brake Pedal Pressed

$1018 Parking Brake Not Engaged

$1019 Parking Brake Engaged

$101A Implement is Swinging/Travelling

$101B Machine Speed Not Zero

Página 32 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...

Page 33: Calibracion NFC Con PRV (2007)

Copyright 1993 - 2007 Caterpillar Inc. Todos los derechos reservados. Red privada para licenciados del SIS.

Wed Oct 24 10:29:59 EST 2007

Página 33 de 33Búsqueda del medio - RENR7389 - 320D, 321D, 323D, 324D, 325D, 328D and ...

24/10/2007https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s...


Recommended