+ All Categories
Home > Documents > Calle La Gitanilla 17, Nave 26 CP: 29004 - Málaga, …...Calle La Gitanilla 17, Nave 26 CP: 29004 -...

Calle La Gitanilla 17, Nave 26 CP: 29004 - Málaga, …...Calle La Gitanilla 17, Nave 26 CP: 29004 -...

Date post: 07-Jun-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
2
Monsol 1000/1500 HALL (Photovoltaic string current monitor) Number of channels Up to 32 channels Number of strings per channel 3 strings (96 strings in total) Max. current per channel 35 A DC (3 strings parallel) Current measurement range ±30 A Pole max. measurement voltage Up to 1,500 V Current measurement error ±1 % (FS) Communication Modbus RTU over RS-485 Number of digital inputs 2 Number of analogue inputs 1 (pt 100) Max. elevation 3500 m AMSL Operating temperature range Min. -40º C, max. 80º C Supply voltage 24 V DC ± 10 % DIMENSIONS Length x Thickness x Width 170x20x82mm EXTRAS Monsol 1500_Volt Extension Max. voltage; measurement error 1500Vdc; error ± 1% (FS) MONSOL METEO EXTENSION Analogue inputs for weather sensors 4 (4.20 mA) Measurement resolution 14 bits Calle La Gitanilla 17, Nave 26 CP: 29004 - Málaga, España Tel. HQ: (+34) 952 02 05 80 [email protected] | monsol.net
Transcript
Page 1: Calle La Gitanilla 17, Nave 26 CP: 29004 - Málaga, …...Calle La Gitanilla 17, Nave 26 CP: 29004 - Málaga, España Tel. HQ: (+34) 952 02 05 80 info@monsol.net | monsol.net CURRENT

Monsol 1000/1500 HALL (Photovoltaic string current monitor)

Number of channels Up to 32 channels

Number of strings per channel 3 strings (96 strings in total)

Max. current per channel 35 A DC (3 strings parallel)

Current measurement range ±30 A

Pole max. measurement voltage Up to 1,500 V

Current measurement error ±1 % (FS)

Communication Modbus RTU over RS-485

Number of digital inputs 2

Number of analogue inputs 1 (pt 100)

Max. elevation 3500 m AMSL

Operating temperature range Min. -40º C, max. 80º C

Supply voltage 24 V DC ± 10 %

DIMENSIONS

Length x Thickness x Width 170x20x82mm

EXTRAS

Monsol 1500_Volt Extension

Max. voltage; measurement error 1500Vdc; error ± 1% (FS)

MONSOL METEO EXTENSION

Analogue inputs for weather sensors 4 (4.20 mA)

Measurement resolution 14 bits

Calle La Gitanilla 17, Nave 26CP: 29004 - Málaga, España

Tel. HQ: (+34) 952 02 05 [email protected] | monsol.net

Page 2: Calle La Gitanilla 17, Nave 26 CP: 29004 - Málaga, …...Calle La Gitanilla 17, Nave 26 CP: 29004 - Málaga, España Tel. HQ: (+34) 952 02 05 80 info@monsol.net | monsol.net CURRENT

CURRENT MONITOR FOR PV PANEL STRINGS

Established in 2005, Monsol specializes in the design, development

and manufacturing of software and hardware for the monitoring of

PV installations. We are now broadening our range of individual string

monitoring devices to achieve the highest possible measurement

accuracy, avoid obstructions to the flow of current, simplify the installation

and guarantee a better performance of the installation. Thanks to its

groundbreaking new connection concept and the innovative measuring

and manufacturing technology, this new device reduces both, space and

installation costs. (C.E./U.L. Certification)

Monsol 1000/1500 Hall® is a measuring device

designed to monitor current flowing from the

first or second level combiner boxes all the way

to the inverter. Its design replaces a multi-phase electric

distribution busbar. We recommend that it should be

installed during the assembly of the first level combiner box.

TECHNICAL PARAMETERS

• Up to 32 channels per device (1 master +3 slaves)• 35 A per channel (3 strings parallel)• Non-intrusive current monitoring by Hall system• Reading precision error ±1 % (FS) (14 bits)• Compatible with 1000V and 1500V strings• Up to 60 readings per minute• 2 closed/open type isolated digital inputs• 1 input for PT100 sensors• RS485 port

- Standard Modbus RTU protocol- 3kV isolation- Surge protection- Transient voltage protected

• Selection of Modbus address by microswitch• Industrial operating temperature range -40ºC to +80º• LEDs indicating power supply and data flow• Power supply of 24 V DC ± 10% with 3kV isolation

- Surge protection - Transient voltage protected - Polarity reversal protection

• PCB thickness of 2 mm suited for industrial handling• Innovative manufacturing technology for high current• Current busbar of up to 240 A without an additional busbar (copper plate)• Electroless nickel immersion gold finish for maximum conductivity• Auto-detection of extension modules• 2 years warranty• Epoxi resin overmolding and tropicalized PCB• Extras:

- Monsol Meteo® extension module with four 4.20mA analogue high accuracy inputs

- Monsol 1500 Volt® extension module monitoring voltage of up to 1500 V DC

IMPORTANT: On request, it is possible to personalize the

configuration of the output busbar. On default, there are 8 inputs

and one single busbar output. The new design allows the division

of the single PCB busbar to offer different output configurations

such as: 8 separate inputs and 2 outputs, each joining 4 inputs; or 4

outputs, each joining 2 input strings; or 8 separate outputs, one for

each input, etc..

RS485

DIN0

DIN_com

DIN1

24vGND

12

13

22

13

Operating temperature -40 to +80º C

MAESTRO ESCLAVO

Monitoring up to 32 current inputs (3 strings parallel imputs)

HOMOLOGATION:Temperature testing

EN 60068-1-1:2007

EN 60068-2-1:2007

UL 61010 (PENDING) Maximum increase: 10 degrees above ambient temperature

Enhanced safety

Up to 1500 V / 35 A

8 8 8 86 6 66

18 18 18 18 18 18 18 8.5

170

82

8

12 23.5

27

39.2 18 18 18 18 18 18 18

Extension module Monsol 1500 Volt® has been

designed to measure the individual voltage of each

box and observe the voltage drop by comparing the

voltage of the string box with that of the inverter input.

Reading precision error of this device is ±1%(FS) and it

is compatible with both poles.

8 inputs

2 outputs

8 inputs

4 outputs

8 inputs

8 outputs


Recommended