+ All Categories
Home > Documents > Camden Council · r.l. main floor 94.80 m j i h g f e d c b a q p o n m l 6900 6900 6900 6900 6900...

Camden Council · r.l. main floor 94.80 m j i h g f e d c b a q p o n m l 6900 6900 6900 6900 6900...

Date post: 19-Aug-2020
Category:
Upload: others
View: 5 times
Download: 0 times
Share this document with a friend
6
Transcript
Page 1: Camden Council · r.l. main floor 94.80 m j i h g f e d c b a q p o n m l 6900 6900 6900 6900 6900 6900 5950 5950 5950 7200 7200 7200 7200 7200 7200 f a09 d a09 e a09 existing building
Page 2: Camden Council · r.l. main floor 94.80 m j i h g f e d c b a q p o n m l 6900 6900 6900 6900 6900 6900 5950 5950 5950 7200 7200 7200 7200 7200 7200 f a09 d a09 e a09 existing building
Page 3: Camden Council · r.l. main floor 94.80 m j i h g f e d c b a q p o n m l 6900 6900 6900 6900 6900 6900 5950 5950 5950 7200 7200 7200 7200 7200 7200 f a09 d a09 e a09 existing building
Page 4: Camden Council · r.l. main floor 94.80 m j i h g f e d c b a q p o n m l 6900 6900 6900 6900 6900 6900 5950 5950 5950 7200 7200 7200 7200 7200 7200 f a09 d a09 e a09 existing building

R.L.

MAIN FLOOR

94.80 m

A B C D E F G H I J

L M N O P Q

6900 6900 6900 6900 6900 6900

7200 7200 7200 7200 7200 7200 5950 5950 5950 3765

F

A09

D

A09E

A09

9MM 'JAMES HARDIE''EXOTEC' FACADE PANEL

'COLORBOND' METALROOFING

'COLORBOND' CORRUGATEDMETAL CLADDING POWDER COATED ALUMINIUM

FRAMED GLAZINGPOWDER COATED ALUMINIUMADJUSTABLE LOUVRES

'EDMONDS EP600'MECHANICAL VENTS

K

R

EX. G.L.

POLYCARBONATE ANTI-CONDENSATION'AMPELITE' SKYLIGHTS TOP OF ROOF R.L. 105.465

1066

5EXISTING CARPARK METAL WALLSAND CURVED ROOF

9500

R.L.

MAIN FLOOR

94.80 m

12345678910111213141516171819202172007200720072007200720072007200720072007200720072007200590059005900590059005900

A

A08

B

A08

G

A09

C

A08

9MM 'JAMES HARDIE''EXOTEC' FACADE PANEL

POWDER COATEDALUMINIUM FIXED LOUVRES

EXISTING BUILDING

POWDER COATEDALUMINIUM FRAMEDGLAZING

'EDMONDS EP600'MECHANICAL VENTS

H

A10

TOP OF ROOF R.L. 105.465

1066

5

2 X 25000L RAINWATERCOLLECTION TANKS

'COLORBOND' CORRUGATEDMETAL CLADDING

HORIZONTAL ALUMINIUM BATTEN SCREEN WALL TOEXTERNAL PLANT PLATFORMBEYOND

9500

R.L.

MAIN FLOOR

94.80 m

ABCDEFGHIJ

LMNOPQ6900 6900 6900 6900 6900 6900

5950 5950 5950 7200 7200 7200 7200 7200 7200

F

A09

D

A09

E

A09

EXISTINGBUILDING

POWDER COATED ALUMINIUMFRAMED GLAZING

'COLORBOND' CORRUGATEDMETAL CLADDING

'COLORBOND' METALROOFING

K

R

1066

5

TOP OF ROOF R.L. 105.465

9500'COLORBOND' CORRUGATED

METAL CLADDING

EXISTING CONCRETEBLOCKWORK

EXISTING CARPARK METALWALLS AND CURVED ROOF

R.L.

MAIN FLOOR

94.80 m

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 217200 7200 7200 7200 7200 7200 7200 7200 7200 7200 7200 7200 7200 7200 5900 5900 5900 5900 5900 5900

A

A08

B

A08

G

A09C

A08

MAIN ENTRY POWDER COATEDALUMINIUM FRAMEDGLAZING

EXISTING BUILDING

'COLORBOND' CORRUGATEDMETAL CLADDING

9MM 'JAMES HARDIE''EXOTEC' FACADE PANEL

EX. G.L.

'EDMONDS EP600'MECHANICAL VENTS

TOP OF ROOF R.L. 105.465

1066

5

H

A10

CUT NEW OPENING TO EXISTING WALL-NEW GLAZED CURTAIN WALL(NEW STAGE 2 TEMPORARY ENTRY)

EXISTING CONCRETEBLOCKWORK

EXISTING TRANSLUCENTPOLYCARBONATE SHEETING

9MM 'JAMES HARDIE''EXOTEC' FACADE PANEL

9500

SCALE:

DRAWN BY:

DATE:

JOB NO.:

DRAWING TITLE:

PROJECT NAME:

CLIENT:

DESIGN ARCHITECT:

Facility Design Group19 The Terrace

Cambewarra, NSW 2540web: www.fdg.com.au

Phone: (02) 4446 0777Fax : (02) 4446 1077Email : [email protected]

A R C H I T E C T S

COPYRIGHT FACILITY DESIGN GROUP PTY. LIMITED. ALL RIGHTS RESERVED.DO NOT SCALE OFF DRAWINGS. WORK TO FIGURED DIMENSIONS ONLY.VERIFY DIMENSIONS ON SITE PRIOR TO COMMENCING WORK.

DRAWING NO.

CHECKED BY:E.BALATTI S. JOHANSSON

NSW Reg. No. 7168

ISSUE DATE BY

B1 PRINT SIZE

LOT 1101, DP 884135, WELLING DRIVE,MOUNT ANNAN

MOUNT ANNAN LEISURE CENTRESTAGE 2

STRUCTURAL AND CIVIL ENGINEER:

CONSULTINGENGINEERS

304/12 Century CircuitNorwest CentralBAULKHAM HILLS NSW 2153Phone : (02) 9894 8500Fax : (02) 8850 [email protected]

ECLIPSEECLIPSE Consulting Engineers Pty Ltd

ELECTRICAL ENGINEER:

HYDRAULIC ENGINEER:

1 Davis PlaceGlenhaven NSW 2156S P E C T R U M

ENGINEERING SOLUTIONS Phone: (02) 8850 6802Mobile: 0419 294 533Email : [email protected]

SMScorp pty ltd

acn 80 158 133 110po box 480Milsons Point 1565

T 9438 1022 F 9438 2124e [email protected]

MECHANICAL ENGINEER:

5.5.15CONCEPTUAL DESIGN EB

CAMDEN COUNCIL

L1, Bldg 30 Cockatoo Island,PO Box 31, Manly, NSW, 1655

Phone: (02) 9810 9902Mobile: 0419 977 808Email : [email protected]

11.6.15DEVELOPED DESIGN EB

30.6.15DEVELOPMENT APPLICATION EB

1 : 200

ELEVATIONS

Project Number

Issue Date

A07

1 : 200EAST ELEVATION

1 : 200NORTH ELEVATION

1 : 200WEST ELEVATION

1 : 200SOUTH ELEVATION

Page 5: Camden Council · r.l. main floor 94.80 m j i h g f e d c b a q p o n m l 6900 6900 6900 6900 6900 6900 5950 5950 5950 7200 7200 7200 7200 7200 7200 f a09 d a09 e a09 existing building

R.L.

MAIN FLOOR

94.80 m

ABCDEFGHIJ

LMNOPQF

A09

D

A09

3200

6900 6900 6900 6900 6900 6900

3765 5950 5950 5950 7200 7200 7200 7200 7200 7200

E

A09

K

R

EXISTING TRANSLUCENTPOLYCARBONATE SHEETING

DISPLAY

CAFESALEKITCHENSTORE

GROUPEXCERISE

EXISTINGCONCRETE SLAB

NEW CONCRETESLAB TO ENG. SPEC.

SOLARPHOTOVOLTAIC CELLS

9500

R.L.

MAIN FLOOR

94.80 m

ABCDEFGHIJ

LMNOPQF

A09

D

A09

6900 6900 6900 6900 6900 6900

3765 5950 5950 5950 7200 7200 7200 7200 7200 7200

E

A09

K

R

ADMIN. MGR LOUNGEMULTI-PURPOSE

EXISTING TRANSLUCENTPOLYCARBONATE SHEETING

HORIZONTAL ALUMINIUMBATTEN SCREEN WALL TO

EXTERNAL PLANT PLATFORM

9500

EXTERNAL PLANT AREA

CARDIO MALECHANGE

MALECHANGE

PLAY

2400

3200

'COLORBOND'METAL ROOFING

R.L.

MAIN FLOOR

94.80 m

A B C D E F G H I

L M N O P QF

A09D

A09

690069006900690069006900

59505950720072007200720072007200

E

A09R

SPORTS HALLMALE

9500

SCALE:

DRAWN BY:

DATE:

JOB NO.:

DRAWING TITLE:

PROJECT NAME:

CLIENT:

DESIGN ARCHITECT:

Facility Design Group19 The Terrace

Cambewarra, NSW 2540web: www.fdg.com.au

Phone: (02) 4446 0777Fax : (02) 4446 1077Email : [email protected]

A R C H I T E C T S

COPYRIGHT FACILITY DESIGN GROUP PTY. LIMITED. ALL RIGHTS RESERVED.DO NOT SCALE OFF DRAWINGS. WORK TO FIGURED DIMENSIONS ONLY.VERIFY DIMENSIONS ON SITE PRIOR TO COMMENCING WORK.

DRAWING NO.

CHECKED BY:E.BALATTI S. JOHANSSON

NSW Reg. No. 7168

ISSUE DATE BY

B1 PRINT SIZE

LOT 1101, DP 884135, WELLING DRIVE,MOUNT ANNAN

MOUNT ANNAN LEISURE CENTRESTAGE 2

STRUCTURAL AND CIVIL ENGINEER:

CONSULTINGENGINEERS

304/12 Century CircuitNorwest CentralBAULKHAM HILLS NSW 2153Phone : (02) 9894 8500Fax : (02) 8850 [email protected]

ECLIPSEECLIPSE Consulting Engineers Pty Ltd

ELECTRICAL ENGINEER:

HYDRAULIC ENGINEER:

1 Davis PlaceGlenhaven NSW 2156S P E C T R U M

ENGINEERING SOLUTIONS Phone: (02) 8850 6802Mobile: 0419 294 533Email : [email protected]

SMScorp pty ltd

acn 80 158 133 110po box 480Milsons Point 1565

T 9438 1022 F 9438 2124e [email protected]

MECHANICAL ENGINEER:

5.5.15CONCEPTUAL DESIGN EB

CAMDEN COUNCIL

L1, Bldg 30 Cockatoo Island,PO Box 31, Manly, NSW, 1655

Phone: (02) 9810 9902Mobile: 0419 977 808Email : [email protected]

11.6.15DEVELOPED DESIGN EB

30.6.15DEVELOPMENT APPLICATION EB

1 : 100

SECTIONS 1

Project Number

Issue Date

A08

1 : 100SECTION A

1 : 100SECTION B

1 : 100SECTION C

Page 6: Camden Council · r.l. main floor 94.80 m j i h g f e d c b a q p o n m l 6900 6900 6900 6900 6900 6900 5950 5950 5950 7200 7200 7200 7200 7200 7200 f a09 d a09 e a09 existing building

R.L.

MAIN FLOOR

94.80 m

10 11 12 13 14 15

A

A08

B

A08

7200 7200 7200 7200 7200

H

A10

GROUPEXCERISE

2400

3200CARDIO

SOLAR PHOTOVOLTAIC CELLS

'COLORBOND'METAL ROOFING

POWDER COATED ALUMINIUMFRAMED GLAZING

101112131415

A

A08

B

A08

72007200720072007200

H

A10

SOLAR PHOTOVOLTAIC CELLS

HORIZONTALALUMINIUM BATTEN

SCREEN WALL

EXISTING CURVEDROOF BEYOND

'COLORBOND'CORRUGATED METAL

CLADDING

9MM 'JAMES HARDIE''EXOTEC' FACADE

PANEL

R.L.

MAIN FLOOR

94.80 m

101112131415161718192021

A

A08

72007200720072007200590059005900590059005900

B

A08

7000

G

A09C

A08

HAU

NC

H H

EIG

HT

6606

1066

5

35400STORE

SPORTS HALL

CRECHE ADMIN. MULTI-PURPOSE CONTROL

EXSITINGPOOL HALL

EX. G.L.

RAD

IUS TO

UN

DER

SIDE O

F RO

OF

52270

'COLORBOND'METAL ROOFING

CONCRETEWALL PANEL

1182

TOP OF ROOF R.L. 105.465

H

A10

R.L.

MAIN FLOOR

94.80 m

LMNOPQ F

A09

6900 6900 6900 6900 6900 6900

R

SPORTS HALL

POLYCARBONATE ANTI-CONDENSATION'AMPELITE' SKYLIGHTS

MALE

'COLORBOND' METAL ROOFING

POWDER COATED ALUMINIUMADJUSTABLE LOUVRES

3700

EXISTING G.L.

SCALE:

DRAWN BY:

DATE:

JOB NO.:

DRAWING TITLE:

PROJECT NAME:

CLIENT:

DESIGN ARCHITECT:

Facility Design Group19 The Terrace

Cambewarra, NSW 2540web: www.fdg.com.au

Phone: (02) 4446 0777Fax : (02) 4446 1077Email : [email protected]

A R C H I T E C T S

COPYRIGHT FACILITY DESIGN GROUP PTY. LIMITED. ALL RIGHTS RESERVED.DO NOT SCALE OFF DRAWINGS. WORK TO FIGURED DIMENSIONS ONLY.VERIFY DIMENSIONS ON SITE PRIOR TO COMMENCING WORK.

DRAWING NO.

CHECKED BY:E.BALATTI S. JOHANSSON

NSW Reg. No. 7168

ISSUE DATE BY

B1 PRINT SIZE

LOT 1101, DP 884135, WELLING DRIVE,MOUNT ANNAN

MOUNT ANNAN LEISURE CENTRESTAGE 2

STRUCTURAL AND CIVIL ENGINEER:

CONSULTINGENGINEERS

304/12 Century CircuitNorwest CentralBAULKHAM HILLS NSW 2153Phone : (02) 9894 8500Fax : (02) 8850 [email protected]

ECLIPSEECLIPSE Consulting Engineers Pty Ltd

ELECTRICAL ENGINEER:

HYDRAULIC ENGINEER:

1 Davis PlaceGlenhaven NSW 2156S P E C T R U M

ENGINEERING SOLUTIONS Phone: (02) 8850 6802Mobile: 0419 294 533Email : [email protected]

SMScorp pty ltd

acn 80 158 133 110po box 480Milsons Point 1565

T 9438 1022 F 9438 2124e [email protected]

MECHANICAL ENGINEER:

5.5.15CONCEPTUAL DESIGN EB

CAMDEN COUNCIL

L1, Bldg 30 Cockatoo Island,PO Box 31, Manly, NSW, 1655

Phone: (02) 9810 9902Mobile: 0419 977 808Email : [email protected]

11.6.15DEVELOPED DESIGN EB

30.6.15DEVELOPMENT APPLICATION EB

1 : 100

SECTIONS 2

Project Number

Issue Date

A09

1 : 100SECTION D

1 : 100SECTION E

1 : 100SECTION F

1 : 100SECTION G

WEIGHTS MALECHANGE

FEMALECHANGE SALE

EXSITINGPOOL HALL


Recommended