16
53 Level Capacitive Overview 54 VEGACAL series 60 56
Transcript
Page 1: Capacitive - AC Controls

53

Leve

l

CapacitiveOverview 54

VEGACAL series 60 56

Page 2: Capacitive - AC Controls
Page 3: Capacitive - AC Controls
Page 4: Capacitive - AC Controls

56

2

3

1

L L

102

mm

(402

")

ø 40 mm(1.58")

SW 36 mm (1.42")

G ¾

56 m

m(2

21")

56 m

m(2

21")

22 m

m(0

87")

ø 16 mm(0.63")

72 m

m(2

84")

ø 12 mm(0.47")

Capacitive – VEGACAL 62

1 Threaded version

2 Flange version

3 Threaded version with temperature adapter +200 °C

VEGACAL 62 Capacitive rod electrode for continuous level measurement Application area The VEGACAL 62 is a level sensor for continuous level measurement in all areas of industry. The partly insulated probe is ideal for the measurement of bulk solids and can also be used in non-conductive liquids such as e.g. oil. The proven mechanical construction ensures high functional safety. Advantages Long lifetime and low maintenance requirement through robust mechanical

construction High flexibility through shortenable probe Maximum use of the vessel, because measurement over the complete probe

length Technical data Version: partly insulated rod Measuring range: up to 6 m Process fitting: thread from G¾, ¾ NPT flanges from DN 25, 1" Materials: steel, 316L, PTFE Process temperature: -50 … +200 °C Process pressure: -1 … +64 bar (-100 … +6400 kPa) SIL qualification: up to SIL2

Page 5: Capacitive - AC Controls

57Capacitive – VEGACAL 62

ApprovalXX without ................................................................................................................................................................XM Ship approval .....................................................................................................................................................

Version / Process temperatureA Standard / -50 ... 150°C ...............................................................................................................................B Standard / -50 ... 200°C ...............................................................................................................................C with screening tube PN1 316L / -50 ... 150°C ..............................................................................................D with screening tube PN1 316L / -50 ... 200°C ...............................................................................................I with concentric tube 316L/-50...150°C ......................................................................................................

J with concentric tube 316L/-50...200°C .....................................................................................................

Process fitting / MaterialNH Thread ½NPT (ASME B1.20.1) PN64 / 316L ...................................................................................NA Thread ¾NPT (ASME B1.20.1) PN64 / 316L ...................................................................................NC Thread 1NPT (ASME B1.20.1) PN64/316L ......................................................................................ND Thread 1½NPT (ASME B1.20.1) PN64/316L ...................................................................................AA Flange 1"150lb RF,ANSI B16.5/316L ...............................................................................................BA Flange 1"300lb RF,ANSI B16.5/316L ...............................................................................................DA Flange 1½"150lb RF,ANSI B16.5/316L ............................................................................................EA Flange 1½"300lb RF,ANSI B16.5/316L ............................................................................................EC Flange 1½"300lb ST,ANSI B16.5/316L .............................................................................................HA Flange 2"150lb RF,ANSI B16.5/316L ...............................................................................................IA Flange 2"300lb RF,ANSI B16.5/316L ...............................................................................................

KA Flange 2"600lb RF,ANSI B16.5/316L ...............................................................................................OA Flange 3"150lb RF,ANSI B16.5/316L ...............................................................................................PA Flange 3"300lb RF,ANSI B16.5/316L ...............................................................................................2A Flange 3"600lb RF,ANSI B16.5/316L ...............................................................................................SA Flange 4"150lb RF,ANSI B16.5/316L ...............................................................................................UA Flange 4"300lb RF,ANSI B16.5/316L ...............................................................................................3A Flange 5"150lb RF,ANSI B16.5/316L ...............................................................................................

WA Flange 6"150lb RF,ANSI B16.5/316L ...............................................................................................VA Flange 6"300lb RF,ANSI B16.5/316L ...............................................................................................

ElectronicsH 4...20mA/HART® .........................................................................................................................X for connection to a signal conditioning instrument ......................................................................P Profibus PA ..................................................................................................................................F Foundation Fieldbus ....................................................................................................................

Housing / ProtectionK Plastic / IP66/IP67 ................................................................................................................A Aluminium / IP66/IP68 (0.2 bar) ...........................................................................................D Aluminium double chamber / IP66/IP68 (0.2 bar) ...............................................................8 StSt (electropolished) 316L / IP66/IP68 (0.2bar) .................................................................R Plastic 2-chamber / IP66/IP67 ..............................................................................................

Cable entry / Cable gland / Plug connectionN ½NPT / without / without ...............................................................................................

Indicating/adjustment module (PLICSCOM)X without .....................................................................................................................A mounted ...................................................................................................................

Additional equipmentX Without ..............................................................................................................

CL62.

Length (from seal surface)316L (100-6000 mm) per 100 mm

Length screening tube316L (50-5960 mm) per 100 mm

Insulation lengthPTFE insulated (50-5990 mm) per 100 mm

Leve

l

Page 6: Capacitive - AC Controls

58

2

3

1

L L

SW 36 mm (1.42")

G ¾

56 m

m(2

21")

56 m

m(2

21")

22 m

m(0

87")

ø 16 mm(0.63")

102

mm

(402

")

ø 40 mm(1.58")

Capacitive – VEGACAL 63

1 Threaded version

2 Flange version

3 Threaded version with temperature adapter +200 °C

VEGACAL 63 Capacitive rod electrode for continuous level measurement Application area The VEGACAL 63 level sensor can be used universally for the measurement of conductive liquids. The rod electrode is fully insulated and the proven construction ensures high functional safety. Advantages Long lifetime and low maintenance requirement through robust mechanical

construction Savings through simple mounting and setup Maximum use of the vessel, because measurement over the complete probe

length Technical data Version: fully insulated rod Measuring range: up to 6 m Process fitting: thread from G¾, ¾ NPT flanges from DN 25, 1" Materials: 316L, PE, PTFE Process temperature: -50 … +200 °C Process pressure: -1 … +64 bar (-100 … +6400 kPa) SIL qualification: up to SIL2

Page 7: Capacitive - AC Controls

59Capacitive – VEGACAL 63

ApprovalXX without ............................................................................................................................................................................XM Ship approval .................................................................................................................................................................

Version / Process temperatureE PE insulation / -40...80°C .........................................................................................................................................F PTFE insulation / -50...150°C ...................................................................................................................................G PTFE insulation / -50...200°C ...................................................................................................................................H PE insulation and concentric tube 316L / -40...80°C ...............................................................................................I PTFE insulation and concentric tube 316L / -50...150°C .........................................................................................J PTFE insulation and concentric tube 316L / -50...200°C .........................................................................................

Process fitting / MaterialNH Thread ½NPT (ASME B1.20.1) PN64 / 316L .................................................................................................NA Thread ¾NPT (ASME B1.20.1) PN64 / 316L .................................................................................................NC Thread 1NPT (ASME B1.20.1) PN64 / 316L ..................................................................................................ND Thread 1½NPT (ASME B1.20.1) PN64 / 316L ...............................................................................................NS Thread 1½NPT (ASME B1.20.1) PN64 / Steel ...............................................................................................AA Flange 1"150lb RF,ANSI B16.5/316L .............................................................................................................AD Flange 1"150lb ANSI/316L PTFE-plated ........................................................................................................BA Flange 1"300lb RF,ANSI B16.5/316L .............................................................................................................BD Flange 1"300lb ,ANSI B16.5/316L PTFE-plated ............................................................................................DA Flange 1½"150lb RF,ANSI B16.5/316L ..........................................................................................................DD Flange 1½"150lb ,ANSI B16.5/316L PTFE-plated .........................................................................................EA Flange 1½"300lb RF,ANSI B16.5/316L ..........................................................................................................HA Flange 2"150lb RF,ANSI B16.5/316L .............................................................................................................HD Flange 2"150lb ANSI B16.5/316L PTFE-plated .............................................................................................IA Flange 2"300lb RF,ANSI B16.5/316L .............................................................................................................ID Flange 2"300lb, ANSI B16.5/316L PTFE-plated ............................................................................................

KA Flange 2"600lb RF,ANSI B16.5/316L .............................................................................................................OA Flange 3"150lb RF,ANSI B16.5/316L .............................................................................................................OD Flange 3"150lb ANSI B16.5/316L PTFE-plated .............................................................................................PA Flange 3"300lb RF,ANSI B16.5/316L .............................................................................................................2A Flange 3"600lb RF,ANSI B16.5/316L .............................................................................................................SA Flange 4"150lb RF,ANSI B16.5/316L .............................................................................................................SD Flange 4"150lb ANSI B16.5/316L PTFE-plated .............................................................................................UA Flange 4"300lb RF,ANSI B16.5/316L .............................................................................................................UD Flange 4"300lb ,ANSI B16.5/316L PTFE-plated ............................................................................................3A Flange 5"150lb RF,ANSI B16.5/316L .............................................................................................................

WA Flange 6"150lb RF,ANSI B16.5/316L .............................................................................................................VA Flange 6"300lb RF,ANSI B16.5/316L .............................................................................................................

ElectronicsH 4...20mA/HART® ......................................................................................................................................X for connection to a signal conditioning instrument ...................................................................................P Profibus PA ...............................................................................................................................................F Foundation Fieldbus .................................................................................................................................

Housing / ProtectionK Plastic / IP66/IP67 .............................................................................................................................A Aluminium / IP66/IP68 (0.2 bar) ........................................................................................................D Aluminium double chamber / IP66/IP68 (0.2 bar) .............................................................................8 StSt (electropolished) 316L / IP66/IP68 (0.2bar) ...............................................................................R Plastic 2-chamber / IP66/IP67 ...........................................................................................................

Cable entry / Cable gland / Plug connectionN ½NPT / without / without ............................................................................................................

Indicating/adjustment module (PLICSCOM)X without ..................................................................................................................................A mounted ................................................................................................................................

Additional equipmentX Without ...........................................................................................................................

CL63.

Length (from seal surface)316L/PE fully insulated (100-6000 mm) per 100 mm316L/PTFE fully insulated (100-6000 mm) per 100 mm

Length concentric tube316L (100-6000 mm) per 100 mm

Leve

l

Page 8: Capacitive - AC Controls

60

2

3

1

L L

SW 36 mm (1.42")

G ¾

56 m

m(2

21")

56 m

m(2

21")

22 m

m(0

87")

ø 16 mm (0.63")

102

mm

(402

")

ø 40 mm(1.58")

Capacitive – VEGACAL 64

1 Threaded version

2 Flange version

3 Threaded version with temperature adapter +200 °C

VEGACAL 64 Capacitive rod electrode for continuous level measurement of adhesive products Application area The VEGACAL 64 is a level sensor for conductive liquids. The rod electrode is fully insulated and is particularly suitable for viscous and adhesive products. Advantages Reduced number of cleaning cycles through measurement insensitive to buildup Maximum use of the vessel, because measurement over the complete probe

length Long lifetime and low maintenance requirement through robust mechanical

construction Technical data Version: fully insulated rod Measuring range: up to 4 m Process fitting: thread from G¾, ¾ NPT flanges from DN 25, 1" Materials: 316L, FEP Process temperature: -50 … +150 °C Process pressure: -1 … +64 bar (-100 … +6400 kPa) SIL qualification: up to SIL2

Page 9: Capacitive - AC Controls

61Capacitive – VEGACAL 64

ApprovalXX without ............................................................................................................................................XM Ship approval .................................................................................................................................

Version / Process temperatureR FEP insulation / -50...150°C .....................................................................................................

Process fitting / MaterialNA Thread ¾NPT (ASME B1.20.1) PN64 / 316L .................................................................NC Thread 1NPT (ASME B1.20.1) PN64 / 316L ..................................................................ND Thread 1½NPT (ASME B1.20.1) PN64 / 316L ...............................................................NS Thread 1½NPT (ASME B1.20.1) PN64 / Steel ...............................................................AA Flange 1"150lb RF,ANSI B16.5/316L .............................................................................BA Flange 1"300lb RF,ANSI B16.5/316L .............................................................................DA Flange 1½"150lb RF,ANSI B16.5/316L ..........................................................................EA Flange 1½"300lb RF,ANSI B16.5/316L ..........................................................................HA Flange 2"150lb RF,ANSI B16.5/316L .............................................................................IA Flange 2"300lb RF,ANSI B16.5/316L .............................................................................

KA Flange 2"600lb RF,ANSI B16.5/316L .............................................................................OA Flange 3"150lb RF,ANSI B16.5/316L .............................................................................PA Flange 3"300lb RF,ANSI B16.5/316L .............................................................................2A Flange 3"600lb RF,ANSI B16.5/316L .............................................................................SA Flange 4"150lb RF,ANSI B16.5/316L .............................................................................UA Flange 4"300lb RF,ANSI B16.5/316L .............................................................................3A Flange 5"150lb RF,ANSI B16.5/316L .............................................................................

WA Flange 6"150lb RF,ANSI B16.5/316L .............................................................................VA Flange 6"300lb RF,ANSI B16.5/316L .............................................................................

ElectronicsH 4...20mA/HART® ......................................................................................................X for connection to a signal conditioning instrument ....................................................P Profibus PA ...............................................................................................................F Foundation Fieldbus .................................................................................................

Housing / ProtectionK Plastic / IP66/IP67 .............................................................................................A Aluminium / IP66/IP68 (0.2 bar) .........................................................................D Aluminium double chamber / IP66/IP68 (0.2 bar) ..............................................8 StSt (electropolished) 316L / IP66/IP68 (0.2bar) ...............................................R Plastic 2-chamber / IP66/IP67 ...........................................................................

Cable entry / Cable gland / Plug connectionN ½NPT / without / without .............................................................................

Indicating/adjustment module (PLICSCOM)X without ...................................................................................................A mounted ................................................................................................

Additional equipmentX Without ............................................................................................

CL64.

Length (from seal surface)316L/FEP fully insulated (200-4000 mm) per 100 mm

Leve

l

Page 10: Capacitive - AC Controls

62

2

3

1

SW 41 mm (1.61")

G1

56 m

m(2

21")

58 m

m(2

28")

22 m

m(0

87")

142

mm

(559

")

72 m

m (2

84")

200

mm

(787

")

ø 6 mm(0.24") L L

ø 30 mm(1.18")

102

mm

(402

")

ø 40 mm(1.58")

Capacitive – VEGACAL 65

1 Threaded version

2 Flange version

3 Threaded version with temperature adapter +200 °C

VEGACAL 65 Capacitive cable electrode for continuous level measurement Application area The VEGACAL 65 is a level sensor for use in all industries. The partly insulated probe is ideal for the measurement of bulk solids and can be also used in non-conductive liquids such as for example oil. The proven construction ensures a high functional safety. Advantages Long lifetime and low maintenance requirement through robust mechanical

construction High flexibility through shortenable probe Maximum use of the vessel, because measurement over the complete probe

length Technical data Version: partly insulated cable Measuring range: up to 32 m Process fitting: thread from G1, 1 NPT flanges from DN 50, 1" Materials: 316L, PTFE, PE Process temperature: -50 … +200 °C Process pressure: -1 … +64 bar (-100 … +6400 kPa) SIL qualification: up to SIL2

Page 11: Capacitive - AC Controls

63Capacitive – VEGACAL 65

ApprovalXX without ............................................................................................................................................XM Ship approval ..................................................................................................................................

Version / Process temperatureK Cable ø 6mm / 316 with gravity weight / -50...150°C ................................................................U Cable ø6mm with screening tube a. gr.weight/-50...150°C ......................................................L Cable ø 6mm / 316 with gravity weight / -50...200°C ................................................................V Cable ø6mm w. screening tube a.grav. weight/-50...200°C .....................................................Y Cable ø 6mm / 316 / -50...150°C (without weight) ....................................................................

Process fitting / MaterialNC Thread 1NPT (ASME B1.20.1) PN64 / 316L ...................................................................ND Thread 1½NPT (ASME B1.20.1) PN64 / 316L ................................................................NS Thread 1½NPT (ASME B1.20.1) PN64 / Steel ................................................................HA Flange 2"150lb RF,ANSI B16.5/316L .............................................................................IA Flange 2"300lb RF,ANSI B16.5/316L .............................................................................

KA Flange 2"600lb RF,ANSI B16.5/316L .............................................................................OA Flange 3"150lb RF,ANSI B16.5/316L .............................................................................PA Flange 3"300lb RF,ANSI B16.5/316L .............................................................................2A Flange 3"600lb RF,ANSI B16.5/316L .............................................................................SA Flange 4"150lb RF,ANSI B16.5/316L .............................................................................UA Flange 4"300lb RF,ANSI B16.5/316L .............................................................................3A Flange 5"150lb RF,ANSI B16.5/316L .............................................................................

WA Flange 6"150lb RF,ANSI B16.5/316L .............................................................................VA Flange 6"300lb RF,ANSI B16.5/316L .............................................................................

ElectronicsH 4...20mA/HART® .......................................................................................................X for connection to a signal conditioning instrument ....................................................P Profibus PA ...............................................................................................................F Foundation Fieldbus ..................................................................................................

Housing / ProtectionK Plastic / IP66/IP67 ..............................................................................................A Aluminium / IP66/IP68 (0.2 bar) .........................................................................D Aluminium double chamber / IP66/IP68 (0.2 bar) ..............................................8 StSt (electropolished) 316L / IP66/IP68 (0.2bar) ...............................................R Plastic 2-chamber / IP66/IP67 ............................................................................

Cable entry / Cable gland / Plug connectionN ½NPT / without / without .............................................................................

Indicating/adjustment module (PLICSCOM)X without ...................................................................................................A mounted ................................................................................................

Additional equipmentX Without ............................................................................................

CL65.

Length (from seal surface)316 (400-32000 mm) per 100 mm

Length screening tube316L (70-4000 mm) per 100 mm

Insulation lengthPTFE (50-1000 mm) per 100 mm

Leve

l

Page 12: Capacitive - AC Controls

64

21

ø 8 mm(0.32")

56 m

m(2

21")

22 m

m(0

87")

L L

ø 30 mm(1.18")

177

mm

(697

")

SW 41 mm (1.61")

G1

58 m

m(2

28")

Capacitive – VEGACAL 66

1 Threaded version

2 Flange version

VEGACAL 66 Capacitive cable electrode for continuous level measurement Application area The VEGACAL 66 is a level sensor for use in conductive liquids and bulk solids. The cable probe is fully insulated. The proven construction ensures a high functional safety. Advantages Long lifetime and low maintenance requirement through robust mechanical

construction Savings through simple mounting and setup Maximum use of the vessel, because measurement over the complete probe

length Technical data Version: fully insulated cable Measuring range: up to 32 m Process fitting: thread from G1, 1 NPT flanges from DN 50, 2" Materials: 316L, PTFE Process temperature: -50 … +150 °C Process pressure: -1 … +40 bar (-100 … +4000 kPa) SIL qualification: up to SIL2

Page 13: Capacitive - AC Controls

65Capacitive – VEGACAL 66

ApprovalXX without .............................................................................................................................................XM Ship approval ..................................................................................................................................

Version / Process temperatureN PTFE insulated cable ø8mm w. gravity weight/-50...150°C ......................................................3 Insul.cable w.gravity weight a.screen. tube/-50...150°C ............................................................

Process fitting / MaterialNC Thread 1NPT (ASME B1.20.1) PN64 / 316L ...................................................................ND Thread 1½NPT (ASME B1.20.1) PN40/316L ..................................................................HA Flange 2"150lb RF,ANSI B16.5/316L ..............................................................................IA Flange 2"300lb RF,ANSI B16.5/316L ..............................................................................

KA Flange 2"600lb RF,ANSI B16.5/316L ..............................................................................OA Flange 3"150lb RF,ANSI B16.5/316L ..............................................................................PA Flange 3"300lb RF,ANSI B16.5/316L ..............................................................................2A Flange 3"600lb RF,ANSI B16.5/316L ..............................................................................SA Flange 4"150lb RF,ANSI B16.5/316L ..............................................................................UA Flange 4"300lb RF,ANSI B16.5/316L ..............................................................................3A Flange 5"150lb RF,ANSI B16.5/316L ..............................................................................

WA Flange 6"150lb RF,ANSI B16.5/316L ..............................................................................VA Flange 6"300lb RF,ANSI B16.5/316L ..............................................................................

ElectronicsH 4...20mA/HART® .......................................................................................................X for connection to a signal conditioning instrument .....................................................P Profibus PA ................................................................................................................F Foundation Fieldbus ..................................................................................................

Housing / ProtectionK Plastic / IP66/IP67 ...............................................................................................A Aluminium / IP66/IP68 (0.2 bar) ..........................................................................D Aluminium double chamber / IP66/IP68 (0.2 bar) ...............................................8 StSt (electropolished) 316L / IP66/IP68 (0.2bar) ................................................R Plastic 2-chamber / IP66/IP67 ............................................................................

Cable entry / Cable gland / Plug connectionN ½NPT / without / without ..............................................................................

Indicating/adjustment module (PLICSCOM)X without ....................................................................................................A mounted .................................................................................................

Additional equipmentX Without .............................................................................................

CL66.

Length (from seal surface)316/PTFE insulated (400-32000 mm) per 100 mm

Leve

l

Page 14: Capacitive - AC Controls

66

2 31

SW 46 mm(1.81")

G1 ½

242

mm

(9.5

3")

316

mm

(12.

44")

L L

L1

120

mm

(4.7

2")

23 m

m(0

.91"

)10

0 m

m(3

.94"

)

ø 40 mm(1.58")

ø 38 mm(1.50")

ø 15 mm(0.59")

ø 8 mm(0.32")

200

mm

(7.8

7")

Capacitive – VEGACAL 67

1 Cable version +300 °C

2 Rod version +300 °C

3 Version +400 °C

VEGACAL 67 Capacitive high temperature electrode for level measurement of bulk solids Application area The VEGACAP 67 level sensor can be used universally for continuous level measurement of bulk solids. The rod probe is designed for high temperature applications. Advantages Precise measuring results in virtually all bulk solids and high temperature ranges Long service life and low maintenance due to robust mechanical construction High flexibility through shortenable probe Technical data Version: rod or cable Measuring range: up to 6 m or 32 m Process fitting: thread from G1½, 1½ NPT flanges from DN 50, 2" Materials: steel, 316L, PTFE, ceramic Process temperature: -50 … +400 °C Process pressure: -1 … +16 bar (-100 … +1600 kPa) SIL qualification: up to SIL2

Page 15: Capacitive - AC Controls

67Capacitive – VEGACAL 67

ApprovalXX without ..............................................................................................................................................

Version / Process temperature1 Ceramic-insulated rod probe / -50...300°C .................................................................................3 Ceramic-insulated rod probe / -50...400°C .................................................................................2 Ceramic-insulated cable probe / -50...300°C ..............................................................................4 Ceramic-insulated cable probe / -50...400°C ..............................................................................

Process fitting / MaterialND Thread 1½NPT (ASME B1.20.1) PN16/316L ....................................................................EA Flange 1½"300lb RF,ANSI B16.5/316L ............................................................................HA Flange 2"150lb RF,ANSI B16.5/316L ...............................................................................IA Flange 2"300lb RF, ANSI B16.5/316L ...............................................................................

KA Flange 2"600lb RF,ANSI B16.5/316L ...............................................................................OA Flange 3"150lb RF,ANSI B16.5/316L ...............................................................................PA Flange 3"300lb RF,ANSI B16.5/316L ...............................................................................2A Flange 3"600lb RF,ANSI B16.5/316L ...............................................................................SA Flange 4"150lb RF,ANSI B16.5/316L ...............................................................................UA Flange 4"300lb RF,ANSI B16.5/316L ...............................................................................WA Flange 6"150lb RF,ANSI B16.5/316L ...............................................................................

ElectronicsH 4...20mA/HART® .........................................................................................................X for connection to a signal conditioning instrument ......................................................P Profibus PA .................................................................................................................F Foundation Fieldbus ....................................................................................................

Housing / ProtectionK Plastic / IP66/IP67 ................................................................................................A Aluminium / IP66/IP68 (0.2 bar) ...........................................................................D Aluminium double chamber / IP66/IP68 (0.2 bar) ................................................8 StSt (electropolished) 316L / IP66/IP68 (0.2bar) ..................................................R Plastic 2-chamber / IP66/IP67 ..............................................................................

Cable entry / Cable gland / Plug connectionN ½NPT / without / without ...............................................................................

Indicating/adjustment module (PLICSCOM)X without .....................................................................................................A mounted ..................................................................................................

Additional equipmentX Without ..............................................................................................

CL67.

Length (from seal surface)Rod/316L (275-6000 mm) per 100 mmCable/316 (500-40000 mm) per 100 mm

Leve

l

Page 16: Capacitive - AC Controls

68 Capacitive – VEGACAL


Recommended