+ All Categories
Home > Documents > Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13...

Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13...

Date post: 20-Jan-2021
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
40
3-90-02702R8_11/13 www.harmanstoves.com Please read this entire manual before installation and use of this coal - burning room heater. Failure to follow these instructions could result in property damage, bodily injury or even death. Tested and approved for anthracite rice coal fuel only. Burning of any other type of fuel voids your warranty. Hot glass will cause burns. Do not touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as stove. Alert children and adults to hazards of high temperatures. High temperatures may ignite clothing or other flammable materials. Keep clothing, furniture, draperies and other flammable materials away. HOT SURFACES! Glass and other surfaces are hot during operation and cool down. To obtain a French translation of this manual, please contact your dealer or visit www.harmanstoves.com Pour obtenir une traduction française de ce manuel, s’il vous plaît contacter votre revendeur ou visitez www. harmanstoves.com NOTE WARNING WARNING Installation & Owner’s Manual Care and Operation Model(s): Super Magnum Coal Stoker NOTICE: SAVE THESE INSTRUCTIONS CAUTION ! CAUTION ! Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Do not overfire - If any external part starts to glow, you are overfiring. Reduce feed rate. Overfiring will void your warranty. Comply with all minimum clearances to combustibles as specified. Failure to comply may cause house fire. Check building codes prior to installation. Installation MUST comply with local, regional, state and national codes and regulations. Contact local building or fire officials about restrictions and installation inspection requirements in your area. INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. Call your dealer for questions on Installation, Operation, or Service.
Transcript
Page 1: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

3-90-02702R8_11/13 www.harmanstoves.com

Please read this entire manual before installation and use of this coal - burning room heater. Failure to follow these instructions could result in property damage, bodily injury or even death.

Tested and approved for anthracite rice coal fuel only. Burning of any other type of fuel voids your warranty.

Hot glass will cause burns.• Donottouchglassuntilitiscooled• NEVERallowchildrentotouchglass• Keepchildrenaway• CAREFULLYSUPERVISEchildreninsameroomas

stove.• Alertchildrenandadultstohazardsofhightemperatures. High temperatures may ignite clothing or other

flammable materials.• Keepclothing,furniture,draperiesandotherflammable

materialsaway.

HOT SURFACES!

Glass and other surfaces are hot during operation and cool down.

To obtain a French translation of thismanual, pleasecontactyourdealerorvisitwww.harmanstoves.com

Pourobtenirunetraductionfrançaisedecemanuel,s’ilvous plaît contacter votre revendeur ou visitezwww.harmanstoves.com

NOTE

WARNING

WARNING

Installation & Owner’s ManualCare and Operation

Model(s):Super Magnum Coal Stoker

NOTICE: SAVE THESE INSTRUCTIONS

CAUTION!

CAUTION!

• Donotstoreorusegasolineorotherflammablevaporsand liquids in the vicinity of this or any other appliance.

• Donotoverfire-Ifanyexternalpartstartstoglow,youareoverfiring.Reduce feedrate.Overfiringwillvoidyour warranty.

• Complywithallminimumclearancestocombustiblesasspecified.Failuretocomplymaycausehousefire.

Checkbuildingcodespriortoinstallation.

• InstallationMUSTcomplywith local, regional, stateand national codes and regulations.

• Contactlocalbuildingorfireofficialsaboutrestrictionsandinstallationinspectionrequirementsinyourarea.

INSTALLER: Leave this manual with party responsible for use and operation.OWNER: Retain this manual for future reference.Call your dealer for questions on Installation, Operation, or Service.

Page 2: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

2

Super-Magnum Coal Stoker Stove

Do Not Burn Wet Coal! 3-90-02702R8_11/13

Hearth&HomeTechnologieswelcomesyoutoourtraditionofexcellence!BychoosingaHarman®appliance,youhavebecomepartofa longstanding familycommitted tomeeting theheatingneedsofconsumerswith themostdistinctive,powerfulandresponsiblehomeheatingproductsavailable.TheSuper-Magnumhas huge features in an elegant package, giving you 5000 to 100,000+BTUwhen you need it,automatically.Youneedonlysetyourdesiredroomtemperature,keepthehopperfull,andtheashpanempty.WiththeSuper-Magnum,youwillnoticeevenheatthroughoutyourzoneandalevelofconvenienceyouneverthoughtpossible.TheSuper-MagnumtakesadvantageofHarman’s30+yearsofstovedesign,technologyandmanufacturing.ThishighoutputstovehasSuper-Smartcontrolscoupledwithminimalmaintenance.Outputismanagedbyamicroprocessorthatsensestheroomtemperatureandthefiretemperaturewithtwothermistorprobesandthendeterminesthebestfeedrateforyourheatingdemand.TheplatinumcombinationisHarman’sPatentedVerti-FlowTMFeedersystem,andESPControlwhichhavebeendevelopedtotheirhigheststate.Thesefeaturesworktogethertoallowamazingheatoutputwithlittleregardforfuelquality.Wewishyouandyourfamilymanyyearsofenjoymentinthewarmthandcomfortofyourhearthappliance.ThankyouforchoosingHarman®.

Adivisionof Hearth&HomeTechnologies352MountainHouseRoad

Halifax,PA17032www.harmanstoves.com

When This Room Heater Is Not Properly Installed, a House Fire May Result. To Reduce The Risk Of Fire, Follow The Installation Instructions. Contact Local Building Or Fire Officials About Restrictions And Installation Inspection Requirements In Your Area.

Floor protection must be a non-combustible material, and must also be placed under any horizontal sections of chimney

connector pipe, extending 2” (51mm) beyond the measurement of the pipe.

Pour protéger le plancher, il faut sous le poêle un matériau non combustible, qui doit aussi être placé sous les parties horizontales du tuyau de raccord à la cheminée et s’étendre à 51 mm (2 po) au-delà de la mesure du tuyau.

A C

D

BF

E

E

CD

B

A

Parallel Installation Inches Millimeters

Back Wall To Hopper / Entre mur arriereet l’appareil

Side Wall To Unit / Entre mur lateral et l’appareilBack Wall To Flue Pipe / Entre tuyau et le mur arriere

Side Wall To Flue Pipe / Entre tuyau et le mur lateral

2 51

17 43224 610

34 864

F

E

Corner Installation Inches Millimeters

Walls to Unit Body / Entre mur adjacent et l’appareil

Walls to Flue Pipe / Entre tuyau et le mur adjacent

15 381

24 610

JH

G

Floor Protection Requirements Inches Millimeters

Sides / Côtés

Front- from glass/Devant, par rapport au verreRear / Arrière

8 203

12 30518 457

Approved For Use in Mobile/Manufactured Homes- USA ONLYThis appliance is also approved for installation into a shop.“PREVENT HOUSE FIRES”Install and use only in accordance with manufacturer’s installation and operation instructions and local codes. In absence of local codes, installation must meet minimum requirements of NFPA 211 in USA. Refer to manufacturer’s instructions and local codes for precautions required for passing chimney through a combustible wall or ceiling. WARNING FOR MANUFACTURED HOMES: (US Only) Do not install appliance in a sleeping room. An outside air inlet must be provided. The structural integrity of the manufactured home’s floor, walls, and ceiling must be maintained.Refer to manufacturer’s instructions and to local codes for precautions required for passing chimney through a combustible wall or ceiling. Flue connector pipe must be 6” diameter, minimum 24 MSG blue steel. Chimney must be factory built 103HT or masonry construction.DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.FOR USE wITH ANTHRACITE “RICE” COAL ONLY Do not burn wet coal.DO NOT Overfire - If Heater or chimney connector glows, you are overfiring.Input Rating Maximum: 7.75 lb. Fuel/hr.Electrical Rating: 115 VAC, 60 Hz,3.1 AMPSRoute power cord away from unit. DANGER: Risk of electrical shock. Disconnect power supply before servicing. For further instruction, refer to owner’s manual.Replace glass only with 5mm ceramic, available from your dealer.Appliance must be installed with the legs attached. Do not obstruct airflow under the appliance.DANGER: Risk of Fire or Explosion - Do not burn garbage, gasoline, drain oil or other flammable liquids.WARNING: Risk of FireDo not operate with flue draft exceeding -0.080 in water column.Do not operate with fuel loading or ash removal doors open.Do not store fuel or combustibles within marked clearances.Inspect and clean flues and chimney regularly.

Super Magnum Coal Stoker StovePoêle à charbon Super Magnum

Room Heater- Coal Burning Appareil de chauffage d’appoint au charbon

CLEARANCE TO COMBUSTIBLES / DISTANCES MINIMALES DE SECURITE:

Date of Manufacture / Date de fabrication:2013 2014 2015 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC

Fabriqué par: Hearth and Home Technologies 352 Mountain House Road, Halifax PA 17032 (É.-U.)P.N. 3-90-02700 IGN

CAUTION: HOT wHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN AND CLOTHING AwAY. CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS A CONSIDERABLE DISTANCE AwAY FROM THIS APPLIANCE.ATTENTION: CHAUD LORS DU FONCTIONNEMENT. NE TOUCHEZ PAS L’APPAREIL.GARDEZ LES ENFANTS ET LES VÊTEMENTS ÉLOIGNÉS. TOUT CONTACT PEUT ENTRAÎNER DES BRÛLURES DE LA PEAU. RÉFÉREZ-VOUS À LA PLAQUE SIGNALÉTIQUE ET AU MODE D’EMPLOI. GARDEZ LE MOBILIER ET LES AUTRES MATÉRIAUX COMBUSTIBLES BIEN À L’ÉCART DE L’APPAREIL.

Homologué pour les maisons mobiles et préfabriquées - É.-U. SEULEMENTCet appareil est également homologué pour être installé dans un atelier.«ÉVITEZ LES INCENDIES DE MAISON»N’installez et n’utilisez cet appareil que selon le mode d’installation et le mode d’emploi du fabricant et les codes locaux. En l’absence de codes locaux, l’installation doit au minimum être conforme aux exigences de la norme NFPA 211 aux É.-U. Voir dans les recommandations du fabricant et dans les codes locaux les précautions quant au passage d’une cheminée à travers un mur ou un plafond combustible.MISE EN GARDE POUR LES MAISONS PRÉFABRIQUÉES : (É.-U. seulement) N’installez pas cet appareil dans une chambre à coucher. Une arrivée d’air de combustion extérieur doit être prévue. L’intégrité structurelle du plancher, des murs et du plafond de la maison préfabriquée doit être maintenue.Voir dans les recommandations du fabricant et dans les codes locaux les précautions quant au passage d’une cheminée à travers un mur ou un plafond combustible.Le tuyau de raccord à la cheminée doit être d’un diamètre de 15,25 cm (6 po), au minimum en acier bleu 24 MSG. La cheminée doit être en métal 103HT d’usine ou construite en maçonnerie.NE RELIEZ PAS CE POÊLE À UNE CHEMINÉE QUI SERT POUR UN AUTRE APPAREIL.IL NE FAUT UTILISER QUE DE L’ANTHRACITE «RICE», pas du charbon mouillé.Ne chauffez pas TROP. Si l’appareil ou le raccord de cheminée rougit, c’est que le feu est trop puissant.Consommation maximale : 7,75 lb de carburant/heureCourant alternatif de 115 V, 60 Hz, 3,1 ampèresÉloignez le cordon électrique de l’appareil.DANGER: Risque de décharge électrique. Débranchez la prise avant tout entretien. Pour plus de détails, consultez le mode d’emploi.Ne remplacez le verre que par du verre céramique de 5 mm à obtenir de votre détaillant.L’appareil doit être installé avec ses pieds fixés. N’obstruez pas le passage d’air sous l’appareil.DANGER: Risque d’incendie ou d’explosion. Ne brûlez pas d’ordures, d’essence, d’huile de vidange ni aucun autre liquide inflammable.MISE EN GARDE: Risque d’incendie.N’utilisez pas le poêle avec un conduit de cheminée dépassant -0,080 de colonne d’eau.N’utilisez pas le poêle lorsque les portes du foyer et du cendrier sont ouvertes.Gardez le carburant et les matériaux combustibles en dehors des dégagements prescrits.Inspectez et nettoyez fréquemment les conduits et la cheminée.

GG

H

J

Rev C

BARCODE LABEL008Serial No.No de série:

Report #/ Raport # 135-S-24-6.2Tested to / Testé à: UL1482-1996, UL 391-2006, and ULC-S627-00 Test Date: July 2009

Rapport no 135-S-24-6.2Conforme à UL 1482, UL 391 et ULC S627-00

Date d’essai: Juillet 2009

Page 3: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

3Do Not Burn Wet Coal!

Super-Magnum Coal Stoker Stove

3-90-02702R8_11/13

TABLE OF CONTENTS

Section 1: Listing and Code ApprovalsA.ApplianceCertifications 4B.MobileHomeApproval 4C.GlassSpecifications 4D.ElectricalRating 4E.BTU&EfficiencySpecifications 4

Section 2: Special Warnings and NotesA.CarbonMonoxideWarnings&

Considerations 5B.WetCoal 5

Section 3: Getting StartedA.Design,Installation&Location 6B.FireSafety 6C.ComponentLocator 7D.Pre-UseChecklist 8

Section 4: Dimensions & ClearancesA.ApplianceDimensions 9B.ClearancestoCombustibles 10C.FloorProtection 10

Section 5: Chimneys and VentingA.Draft 11B.ChimneyConnectors 11C.WallPass-Throughs 11D.TheChimney 12E.DraftTestProcedure 14

Section 6: Mobile Home - (US only)A.MobileHomeInstallation 15

Section 7: Appliance Set-UpA.OutsideAirAttachment 16B.LevelingTheAppliance 17C.OptionalHeatTransferkit 17D.AirFilter 17E.OptionalDecorativeTileKit 17F.OptionalDoorTrimKit 18G.RoomSensorInstallation 18

Section 8: Operating InstructionsA.FuelSpecifications 19B.GeneralOperatingInformation 19C.BeforeYourFirstFire 22D.StartingYourFirstFire 22E.FireCharacteristics 22

Section 9: TroubleshootingTroubleshootingChart 23

Section 10: Service & MaintenanceA.Shut-DownProcedure 24B.QuickReferenceMaintenance 24C.GeneralMaintenanceProcedures 25D.MotorsandComponents 28

Section 11: Reference MaterialsA.WiringDiagram 30B.ServicePartsListing 31C.WarrantyPolicy 36

= Contains updated information

Page 4: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

4

Super-Magnum Coal Stoker Stove

Do Not Burn Wet Coal! 3-90-02702R8_11/13

A. Appliance Certification Model: SuperMagnumCoalStokerLaboratory: OMNI-TestLaboratories,Inc.ReportNo. 135-S-24-6.2Type: SolidFuelRoomHeater/Coal Burning Type.Standard(s): UL1482,UL391,&ULCS627-00This appliance is also approved for installation in a shop.

B. Mobile Home ApprovedThis appliance is approved for Installation in mobile/manufactured homes in the US only. The structural integrityofthemobilehomefloor,ceilingandwallsmustbemaintained.Theappliancemustbeproperlygrounded totheframeofthemobilehome,andmustneverbeinstalledin a room designated for sleeping. The unit must haveprovisions for an outside air source when installed in a mobilehome.

C. Glass SpecificationsThis appliance is equipped with 5mm ceramic glass.Replace glass only with 5mm ceramic glass. Pleasecontactyourdealerforreplacementglassifneeded.

D. Electrical Rating115VAC,60Hz,3.1Amps

E. BTU & Efficiency SpecificationsParticulateEmissionsRating:*BTUInput:HeatingCapacity:HopperCapacity:Fuel:ShippingWeight:

110lbs.AnthraciteRiceCoal

543lbs.

2,500sq.ft.ormore5,000-103,000/hr

NotTested

*BTUinputwillvary,dependingonthetypeofcoalyouuseinyourstove.Coalminedfromdifferentveinswilltypicallyhavedifferentburncharacteristics.

1 Listing and Code Approvals

Page 5: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

5Do Not Burn Wet Coal!

Super-Magnum Coal Stoker Stove

3-90-02702R8_11/13

NEVER CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

Installation and repair of this stove should be done by a qualified service person. We recommend that the stove be inspected before use and at least annually by a qualified service person. Periodic cleaning is required throughout the heating season and at the end of each winter for the stove to work efficiently. See cleaning instructions on page 24.

SPECIAL NOTE: DUE TO ASH BUILDUP, IT IS STRONGLY RECOMMENDED TO HAVE YOUR STOVE PROFESSIONALLY CLEANED AND SERVICED ANNUALLY. THIS INCLUDES ALL PARTS OF THE STOVE, AND THE VENTING SYSTEM.

Prevent Rust & Corrosion:Always empty the hopper when not burning for more than a week. When left standing for long periods with wet coal, the feed system will rust and corrode, causing it to seize. If the stoker is then turned "on", damage to the pusher assembly and feed motor could result. This will be considered neglect and will void the warranty on those parts. Always check to see that moving parts are free before using, if the unit has not been burned for a period of time. This can best be determined by running a "Test" cycle and watching the cam block and pusher arm inside the right rear door.

Wet CoalFreshlydeliveredcoaliswatereddowntoeliminatedustwhenloadingandunloading.Wetricecoaldoesnotflowaswellasdrycoal.Wedonotrecommendburningwetcoal;however,werealizeifit'stheonlycoalyouhave,itisbettertoburnitthantobecold.Ifyoumustburnwetcoal,thefeedratewilllikelyneedincreased.Doingthisonceortwiceayearwillnotdamageyourstoveaslongasitishotandburning.Damageiscausedwhenthehopperis left with wet coal in it while the stove is cold. This will causerustandcorrosionandit istotallytheoperator’sfault. Afterthecoaldriesforthreeorfourdays,dependingonconditions,itwillflowandfeedproperly.

NEVER SLEEP IN THE SAME ROOM WITH ANY COAL BURNING STOVE.

Carbonmonoxide,referredtoasCO,isacolorless,odorlessgasthatisproducedduringcombustionofcoalandotherfuels. CO fumes are toxic and can be fatal.TheSuper-MagnumisanaturaldraftsystemwhichreliesonaproperlydesignedchimneytoremoveCOandothercombustionby-productsfromthestove.Eventhoughthisstoveisdesignedtobeassafeaspossible,itisimportantthatyouinstall a CO detector. This is true foroil,gas,orwoodburningproductsaswell.COisnotspecificallyheavierorlighterthanair.Therefore,itisbesttoinstallthedetectorattabletoplevelratherthanontheceilinglikeasmokedetector.

COdetectorsareverysensitiveandmaysoundanalarmforfumesotherthanCOorCOfromsourcesotherthanthestovesuchascarorlawnmowerexhaust.If the alarm sounds 1.Increaseventilationbyopeningwindowsordoors.2.Makesurethestovedoorsandhopperlidareclosedand

latched.3.Checkstoveforelectricalpowerandnormaloperation.4.Checkchimneyforpossibleblockageordown-draft.5.Checkforfalsealarm.

Never use gasoline, lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in this heater. Keep all such liquids well away from the heater while it is in use.

2 Special Warnings and Notes

Page 6: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

6

Super-Magnum Coal Stoker Stove

Do Not Burn Wet Coal! 3-90-02702R8_11/13

A. Design, Installation & Location Considerations1. Appliance LocationConsiderationmustbegiventosafety,convenience,trafficflow,andthefactthattheappliancewillneedachimneyandchimneyconnector.Itisagoodideatoplanyourinstallationon paper, using exact measurements for clearances andfloorprotection,beforeactuallybeginningtheinstallation.Maintain specified vent clearance to combustiblerequirements listedbytheventmanufacturers instructionsandallclearancetocombustibleslistedinthismanual.Checkwithyourlocalbuildingcodeagencybeforeyoubeginyourinstallation.BesurelocalcodesdonotsupersedeULspecifications and always obtain the required permit sothat insuranceprotectionbenefitscannotbeunexpectedlycancelled. Ifanyassistance isrequiredduring installation,please contact your dealer.Werecommendthataqualifiedbuildinginspectorandyourinsurancecompanyrepresentativereviewyourplansbeforeand after the installation.2. Room Sensor LocationThe room sensor's location will have some effect on theappliance'soperation.Whenthesensorislocatedclosetotheappliance, itmay requireahigher setting tokeep therest of the house comfortable. If the sensor is located inanadjacentroom,orfartherawayfromthestove,youwillnoticehighertemperaturesneartheappliance.

B. Fire SafetyMaintain the designated clearances to combustibles.Insulationmustnottouchthechimney.Youmustmaintainthedesignatedairspacearound thechimney.Thisspacearound a chimney is necessary to allow natural heatremovalfromthearea.Insulationinthisspacewillcauseaheatbuildup,whichmayignitewoodframing.NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction.Toprovide reasonablefiresafety, the followingshouldbegivenseriousconsideration:• Installatleastonesmokedetectoroneachfloorof

yourhome.Detectorsshouldbelocatedawayfromthe heating appliance and close to sleeping areas. Followthesmokedetectormanufacturer'splacementandinstallationinstructions,andbesuretomaintainregularly.

• AconvenientlylocatedClassAfireextinguishertocontendwithsmallfiresresultingfromburningembers.

• Apracticedevacuationplan,consistingofatleasttwoescape routes.

• Aplantodealwithahopperfireasfollows:In the event of a hopper fire:a.Evacuatethehouseimmediately.b.NotifyFireDepartment.

FireHazard• Do not operate appliance before

reading and understanding the operating instructions.

• Failure to operate properly maycauseahousefire.

3 Getting Started

CAUTION!• DoNOTconnectthisunittoachimneyflueservicing

another appliance.

• DoNOTconnecttoanyforcedairdistributionductorsystem.

CAUTION!

Page 7: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

7Do Not Burn Wet Coal!

Super-Magnum Coal Stoker Stove

3-90-02702R8_11/13

C. Component Locations

Load Door

Ash Removal Door

Distribution Air FilterDistribution Blower

Air Grill

Heat Transfer Kit Filler Plate

Verti-FlowTM Feeder

Control Panel

Heat Exchange Cleaning Rod

Exhaust Sensing Probe (ESP)

Coal Storage HopperRemovable Hopper Lid

Page 8: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

8

Super-Magnum Coal Stoker Stove

Do Not Burn Wet Coal! 3-90-02702R8_11/13

D. Pre- Use Check List

1. Placetheapplianceinalocationnearthe finalinstallationandfollowtheprocedures below:2. Opentheapplianceandremoveallarticles packedinside.Inspectallitemsforshipping damage.Notifydealerofanymissingor damagedgoods.3. Allsafetywarningshavebeenreadand followed precisely.4. ThisOwner'sManualhasbeenreadinit's entirety.5. Floorprotectionrequirementshavebeen read and followed.6. Theflueconnectorhasbeeninstalledin accordance with the instructions herein.7. Theproperclearancesfromtheappliance andchimneyconnectortocombustibles havebeenmet.8. Themasonrychimneyhasbeencleaned andinspectedbyaprofessional,orthe factorybuiltmetalchimneyisinstalled accordingtothemanufacturersinstructions.9. Thechimneymeetstheminimumheight requirements.10. Alllabelsandhangtagshavebeenremoved fromtheglass.11. Allplatedsurfaceshavebeenwipedclean, ifapplicable.12. Theroomsensorandanyadditionalcable hasbeeninstalledproperly.13. Aproperlygroundedelectricalreceptacleis availablewithinreachoftheunit'spower cord.

Inspect appliance and components fordamage. Damaged parts may impair safeoperation.• DoNOTinstalldamagedcomponents.• DoNOTinstallincompletecomponents.• DoNOTinstallsubstitutecomponents.

Reportdamagedpartstodealer.

• Installationanduseofanydamagedappliance.• Modificationoftheappliance.• InstallationotherthanasinstructedbyHearth&

HomeTechnologies.• Operatingappliancewithoutfullyassemblingall

components.• Operatingappliancewithoutlegsattached.• DoNOTOverfire.Or any such action that may cause a fire hazard.

Fire RiskHearth & Home Technologies disclaimsanyresponsibilityfor,andthewarrantywillbevoidedby,thefollowingactions:

WARNING

WARNING

Page 9: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

9Do Not Burn Wet Coal!

Super-Magnum Coal Stoker Stove

3-90-02702R8_11/13

4 Dimensions & Clearances

A. Appliance Dimensions

6” Dia

35 7

/16”

41 5

/16”

42 3

/8“

40 1

/16“

42 1

/16“

26 3/4“35 7/16“32 5/16“

Page 10: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

10

Super-Magnum Coal Stoker Stove

Do Not Burn Wet Coal! 3-90-02702R8_11/13

B. Clearances To Combustibles

A C

D

BF

E

E

CD

B

A

Parallel Installation Inches Millimeters

BackWallToUnitHopper

SideWallToUnit

BackWallToFlueConnector

SideWallToFlueConnector

251

17432

24610

34864

F

E

Corner Installation Inches Millimeters

WallstoUnitBody

WallstoFlueConnector

15381

24610

C. Floor Protection Requirements Floorprotectionmustbeofanon-combustiblematerial. Itmust be located under the appliance and extend beyondtheapplianceaccordingtothemeasurementsbelow.Floorprotectionmustalsoextendunderanyhorizontalsectionsofchimneyconnectorand2"(50.8mm)beyondeachsideofthe connector. DANGER: The appliance legs may not be removed forinstallation.MinimumSizefloorprotectionis49½"DeepBy42¾"Wide.

J

G

Floor Protection Requirements Inches Millimeters

Sides-USA/CANADA*

Rear-USA

8203

12305

H Front-USA/CANADA* 18457

GG

H

J

54"

54"

Alternate floor protector dimension may be used as long as they satisfy the measurement requirements shown above.Minumum size floor protection for a corner installation hearth pad is 54" x 54" (USA ONLY).

Page 11: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

11Do Not Burn Wet Coal!

Super-Magnum Coal Stoker Stove

3-90-02702R8_11/13

5 Chimneys & Venting

A. DraftDraftiswidelymisunderstood.Itisimportantthatyou,thestoveoperator,realizethatdraft isavariableeffect,notagivenquantity.Stovesandchimneysdonothavedraft,yetdraftisthekeytoyourstove’sperformance.Draft is a force, producedbyanoperating stoveand thechimneytowhichitisattached.Itiscreatedbyhotgasesrisingupthechimney,creatingapressuredifferencebetweentheinsideofyourhomeandtheoutsideair.Itcontinuallymovesfreshcombustionairintothestove,andhotexhaustgasesoutof thestove;without thisconstantflow, thefirewill go out.Other factors, such as barometric pressure, winds, thetightness of the home, the total inside chimney volume,chimneyheightandthepresenceofventingdevicessuchasexhaustfansalsoplayaroleinmaintaininganadequatedraft. Lowbarometric pressures, super insulated homes,andexhaust fanscanreducedraft;windscanplayhavocwithdraft;andtoolargeortoosmallachimneyvolumecancause reduced draft due to the excessive cooling or notenoughroomtoventtheexhaustgases.Introducingoutsideairdirectlytothestovemayhelpremedyalowdraftproblem.Somesignsofinadequatedraftaresmoking,odor,difficultyinmaintainingthefire,andlowheatoutput.Overdraftcanbecausedbyaverytallchimneyevenifitistherecommendedsize,andcancauseoverfiringof your stove.Signsofanoverdraft include rapid fuel consumption, inability to slowthefire,andpartsofthestoveorchimneyconnectorglowingred.Itisimportantthatyoufollowthechimneyguidelinesinthismanual,includingsize,type,andheighttoavoiddraftproblems.Wheninstalledandoperatedaccordingtothismanual,thisunitwill produce enoughhot gases to keep the chimneywarmsothatadequatedraft ismaintainedthroughout theburncycle.

B. Chimney ConnectorsAbarometricdamperisrecommendedforchimneysover15feethigh,andmaybenecessarytopreventover-drafting.Installitintheconnector,approximately12inchesabovetheflueexit.Thebarometricdampershouldbesetsothatthefluedraftwillmaintain-.06to-.08inchesofwatercolumn.The appliancemay be installedwith (.6mm) 24 gaugechimneyconnectorpipe.Thesizeoftheconnectorshouldbe6inchtomatchthesizeofthefluecollaropening.Do not use makeshift components.

Nopartofthechimneyconnectormaypassthroughanatticorroofspace,closetorotherconcealedspace,orthrougha floor or ceiling.Whenever possible, avoid passing theconnectorthroughacombustiblewall;ifyoumust,useanapprovedwallpass-through,describedlaterinthissection.

Assembletheconnectorbeginningatthefluecollar,withthecrimpedendspointingtowardsthestove(tokeepdebrisandcreosoteflakesinsidethesystem).Eachjoint,includingtheonetothestove’sfluecollarandtheonetothechimneyitselfshouldbesecuredwithatleastthreesheetmetalscrews,amaximumof3inchesapart.A1-1/4"(32mm)overlapisrequiredateachjoint,includingthefluecollarattachment.Nomorethantwo90degreeelbowsshouldbeused,andthetotallengthofconnectorshouldnotexceed10feet(3m)Allhorizontalrunsofconnectormusthaveaminimumupwardslopeof1/4"perfoot(20mmpermeter).

C. Wall Pass-thrusItmaybenecessarytopassthechimneyconnectorthroughacombustiblewalltoreachthechimney.Dependingonyourlocalbuildingcodes,andprovincialornationalcodes,thereare several choices for accomplishing this safely.Beforebeginningyour installation, contact local officials, and thechimneymanufacturerforspecificrequirements.Canada: Threemethods are approved by theCSA.Thediagramshowsonemethodrequiringan18"(460mm)airspacebetweentheconnectorandthewall.Itallowsuseofoneortwocoversasdescribedinthediagram.TheothertwomethodsaredescribedindetailinthecurrentissueofCAN/CSAB365,thenationalstandard.United States:ThenationalcodeisNFPA211.Besuretocheckwithlocalauthoritiesbeforebeginningyourinstallation.TheNFPA (NationalFireProtectionAgency) permits fourmethodsforpassingthroughacombustiblewall.Acommonlyusedmethodtopassthroughawalldirectlytoamasonrychimneyistoclearaminimum12"(305mm)aroundtheentirechimneyconnector,andfillitwithbrickmasonrywhichisatleast3.5"(90mm)thick.Afireclayliner,minimum3/8"(9mm)wallthicknessmustrunthroughthebrickwalltothechimneyliner(butnotbeyondtheinnersurfaceoftheliner).Itmustbecementedinplacewithrefractorycement.Thismethodisillustrated.Fordetailsontheotherthreeoptions,refertothemostrecenteditionoftheNFPA211code.

Page 12: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

12

Super-Magnum Coal Stoker Stove

Do Not Burn Wet Coal! 3-90-02702R8_11/13

D. The ChimneyThisunitmustbeinstalledintoachimneyapprovedforusewithsolid-fuelappliances.IntheU.S.,itmustbeconnectedto(1)aprefabricatedchimneycomplyingwiththerequirementsforTypeHTchimneysintheStandardforChimneys,Factory-Built,ResidentialTypeandBuildingHeatingAppliances,UL103,or(2)acode-approvedmasonrychimneywithaflueliner.

InCanada, this unit is listed for usewith prefabricatedchimneys tested and listed to the high temperature (650degreesC)chimneystandard,ULCS-629,orwithacodeapprovedmasonrychimney.

Formobilehomes,(USonly)itmustonlybeinstalledwithprefabricated chimney systems, including the installationcomponents,testedtouseinmobilehomes;thediametershouldmatchthediameterofthefluecollaropening

Theminimumrecommendedheightforanychimneyis16ft. (4.8m)abovefluecollar height.Fornon-mobilehomeinstallations, a round flue (eithermasonry or approvedprefabricated), of either 6" (150mm), 7" (180mm)or 8"(200mm)maybeused.Forsquareorrectangularmasonrychimneys,nominalsizesof8"x8"or8"x12"(200mmx200mm,200mmx300mm)maybeused.

Codesrequirethatsolid-fuelchimneysextend3ft.(0.9m)abovethehighestpointatwhichtheyexitfromtheroof.Then,thechimneymustextend2ft.(6m)abovethehighestpointwithina10ft(3m)radius.Thus,the3foot,2foot,10footrule:

3ft.-Aboveroofexitpoint

2ft.-Higherthananythingwithin-

10ft. ofthechimney.

NOTE:TherestrictionofnotventingmorethanoneappliancetothesameflueappliestotheU.S. specifically.Whileitisnotrecommendedthatyouusethesamechimneyformorethanoneappliance,inCanadacertainexceptionsmaybemade.Besuretocontactyourbuildingcodeinspectionofficialtoseeifthisoptionisallowedinyourarea,andtofindoutthespecificrequirementsforsuchaninstallation.

Do not connect this unit to a chimney flue servicing another appliance.

Hole with minimum clearance of 18” (450mm) Between connector and wall.

Non-combustible cover, one side only. If two covers are used, each must be mounted on non-combustible spacers at least 7/8” (21mm) away from the wall.

1” (25mm)Clearance

AN APPROVED CANADIAN WALL PASS-THROUGHAN APPROVED U.S. WALL PASS-THROUGH

Minimum 2” (50mm)Clearance to Brick

Liner Minimum 12” (50mm) to Brick

Fire Clay Thimble

Chimney ConnectorC

him

ney

Flue

Masonry Chimney Built to NFPA 211 Specifications

Closest Combustible Material

Minimum 12” (300) to Combustibles

AN APPROVED CANADIAN WALL PASS-THROUGH AN APPROVED U.S WALL PASS-THROUGH

More than 10 Ft. (3 m)

10 Ft. (3 m)

2 Ft. (.6 m) Min

Height necessary above any roof surface within 10 Ft. (3 m)

3 Ft. (.9 m) minimum above exit point

Ridge

Chimney

THE 3-FOOT, 2-FOOT, 10 FOOT RULE

Page 13: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

13Do Not Burn Wet Coal!

Super-Magnum Coal Stoker Stove

3-90-02702R8_11/13

Donotburnanyfuelotherthancoal.Neverusehighlyvolatilesubstances in your stove, suchas gasoline,which couldcauseanexplosion.When solid fuels are burned completely, they producewaterandcarbondioxide.However, in longslowburns,asubstantialamountofcarbonmonoxidemaybeproduced.Ifallowedtobuildup,carbonmonoxide(whichisodorless)canprovefatallypoisonous.Properventilationanddraftwillpreventthisfromhappening.Ifyousmellsmoke,thoroughlyventilateyourdwelling,andcontactyourdealerforservice.Re-testthedraftandproperlysetthebarometricdamper.Othercausesofpoorventilationordraftareicing,exhaustfans,ablockedoutsideairinlet,androomairstarvation.Ifyourstoveissluggishandyougetoccasionalodor,checkthesepossibilitiesandincreasetheairflowinyourhome.

4. Installing to a Prefabricated ChimneyWhen venting using a prefabricated chimney, be sureto contact local building code authorities, and to followthemanufacturer’s instructions exactly. Use only themanufacturer’s parts; do not usemakeshift installationtechniques.All prefabricated chimneysmust be tested toeithertheU.S.orCanadianhigh-temperaturestandards,UL103orULCS629.

1. Existing Masonry ChimneysIfyouplanonusingapre-existingmasonrychimney,haveitthoroughlyinspectedandcleaned.Anyfaultswhichmakethechimneyunsafeandunusablemustberepairedpriortouse.Thesecanincludeimproperheight,structuraldefects,blockages,inadequateclearancetocombustibles,unsealedopeningsintootherroomsofthehouse,signsofcreosoteorsmokeleakage,alooseorabsentclean-outdoor,orabsenceof a liner.

2. Venting to a Masonry ChimneyWhenconnectingtoamasonrychimney,severalprovisionsarestandard.First,whetherthechimneyconnectorisventedtothechimneythroughathimbleorabreechpipe,neithermustpassbeyond the innersurfaceof thechimney liner,andbothmustbefirmlycementedinplacewithrefractorycement. (A thimble is amasonry pipewhich is insertedthrough the chimneywall, and is frequently thepreferredmethod;abreechpipeisapieceofsteelpipeusedthesameway.)InCanada,abreechpipehasridgesorprotrusionstolockitfirmlyintotherefractorycement.Ineithercase,thechimneyconnectorventstothechimneythroughthethimbleorbreechpipe.Usingathimble,theconnectorslidescompletelyinsidethemasonrytotheinneredgeoftheflueliner,andmaybeeasilyremoved for chimneyandconnector inspection.Abreechpipemustextendatleast2"(50mm)intotheroom,sotheconnectorcanbeattachedwithsheetmetalscrews.

3. Venting to a Masonry Fireplace ChimneyIn some situations, a code compliant chimney originallyusedforamasonryfireplacemaybeused.Inadditiontotherequirementsfoundinthepreviousparagraphs,itisimportanttobeawarethatallclearancesmustbemet,includingthosefromthechimneyconnectortocombustibles.Donotforgettoincludefloorprotectioninyourplans.(SeeClearancesandFloorProtectioninthissection.)Sincemanyfireplaceshaveexposedwoodenmantelsandtrim,payspecialattentiontotheclearancesnecessarytothesematerials.Ifyourfireplacechimneyisbehindacombustiblewall,youmust use an approvedwall pass-through system to gainaccess to themasonry chimney.The chimney connectormust enter the chimneyat a placewhere it is lined, andthefireplacemustbemade inoperable.Forexample,youmightremovethedamper,replacingitwithasecure,airtight,noncombustible seal (removable for inspection); this alsosatisfiestherequirementthatnoroomairmustbeallowedtoenterthechimney.

Chimney Connector

Clay thimble, reaching just to the inside of the chimney liner

Mechanical fasteners (minimum 3) but not at the bottom of the connector

Chimney liner inner edges

High-temperature sealant used to cement the clay thimble

Page 14: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

14

Super-Magnum Coal Stoker Stove

Do Not Burn Wet Coal! 3-90-02702R8_11/13

E. Draft Test ProcedureBecause of the dangers associated with coal gases and thepotentialforcarbonmonoxiderelease,Itisimportanttobalancetheairflowintothestovewiththedraftintheflue.Thecombustionblowerhasarestrictorplateattachedtoit,whichmustbeadjusteduponcompletionoftheinstallation.The barometric damper, if installed, must also be set topreventover-draftingintheappliance.FollowthesestepstoensuresafeandefficientoperationofyourSuperMagnumcoalstokerstove.

You will need to start a fire in the appliance to establish a draft in the chimney flue. Refer back to these instructions after reading the entire manual.

• Drillaholeintotheflueconnectorpipe,forthepurposeofattachingadraftmeter.Thisholeshouldbebetweenthebarometricdamperandthestove'sfluecollar,andinan inconspicuous location,as itwillbeclosedoffafterthetestwithabolt.

• Attachthedraftmetertotheholeintheconnector.Agreatchimneywillhavedraftwithoutafireorheatsource.Setthebarometricdampertomaintain-.06to-.08(inchesofwatercolumn).

• Removethedraftmeterfromtheconnectorpipeandsealtheholebythreading inascreworbolt.Youmayalsowanttoapplyasmalldabofhigh-temperaturesiliconetothe threads prior to installing.

• Next,removetheset-screwplugboltfromthefrontoftheSuperMagnumbody.Thisplugislocatedinthecenter,justbelowthetoploaddoor.Attachthedraftmeterhoseto the stove.

• Turn the feedadjusterknob to "Test".Thiswill run thecombustion blower at its highest possible voltage orspeed.

• Closetherestrictorovertheopeningtothecombustionbloweruntilthedraftreadinginthefireboxfitsthe-.03to-.04range.Thiswillensurethatthecombustionblowerwillneverpushmoreairintothefireboxthanthedraftintheflueiscapableofremoving.

• Disconnectthedraftmeterfromthestoveandre-installthesetscrewplugbolt.

Draft meter connection locations

Do not operate if the draft in the flue exceeds -.08 in water column.

WARNING!

Page 15: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

15Do Not Burn Wet Coal!

Super-Magnum Coal Stoker Stove

3-90-02702R8_11/13

6 Mobile Home

A. Mobile Home InstallationMobile home approval - U.S. only.1. An outside air inlet must be provided for combustion

air,andmustremainclearofleaves,debris,ice,and/orsnow.Theoutsideairpathmustbeunrestrictedwhiletheappliance is in operation.

2. The combustion air intake system must be of metalconstruction.Itmustpermitzero-clearancetocombustiblematerials,andcontainarodentscreen.

3. The appliance must be secured to the mobile homestructure by bolting it to the floor. There are bracketsincluded,you'llneedtosecurewiththeproperlengthlagbolts.

4. Theappliancemustbegroundedtothemetalframingofthemobilehome

5. All clearances to combustibles and floor protectionrequirementsmustbefollowed.

6. Follow the vent manufacturer's instructions wheninstallinginamobilehome.

7. InstallationshallbeinaccordancewiththeManufacturedHomeandSafetyStandard(HUD)CFR3280,Part24

8. The appliance must never be installed in a roomdesignated for sleeping.

Thisdiagramshowsthebracketthatwasusedtobolt thestove to thepallet.Useat least twoof thesebrackets forsecuringtheappliancethroughthefloorinamobilehomeinstallation.Thebracketwillslipoverthetopofthelevelingadjuster.Theinstallerwillneedtodetermineandobtaintheproperlysizedlagbolts.

Installation must comply with Manufactured Home andSafetyStandard(HUD),CFR3280,Part24.

Never install in a room intended for sleeping.

Maintain structural integrity of mobile home:• Floor, wall, ceiling and/or roof.DoNOTcutthrough:• Floorjoist,wallstuds,orceilingtrusses.• Any supporting material that would affect the

structural integrity.

Neverdrawoutsidecombustionairfrom:• Wall,floororceilingcavity.• Enclosedspacesuchasanatticorgarage

CAUTION!

CAUTION!

WARNING!

WARNING!

Page 16: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

16

Super-Magnum Coal Stoker Stove

Do Not Burn Wet Coal! 3-90-02702R8_11/13

A. Outside Air AttachmentPartsandSuppliesNeeded:1pieceofmetalflexiblepipe,3"Xneededlength.1RodentScreen,Plus,you'llwanttoobtainatrimringforfinishingaroundthepipeontheinsidewall.

1. Removetheknockoutfromthebottomshield.Therearethreesmallareasthatarenotpreviouslycut.Youcancutthesetabsusingahacksaworbydrillingthem.Asmallroundedfilewillbehelpfulinremovinganysharpburrsfromthecut.

2. Determineanappropriateholelocation,throughthewall.Besuretherearenostudsorothersupportingmembers.Also ensure there are no electrical wires or plumbingcontained within the wall.

3. Make the hole through the exterior wall using a holesaworreciprocatingsaw.You'llwanttheholetobejustslightlylargerthanthemetalflexpipe.

4. Attach the rodent screen to one end of the flex pipe,andinsertitthroughthewalluntilthebackofthescreencover is against the outside surface.

5. Hold the flex pipe in place to make an accuratedeterminationofthelengthneeded.Cuttheflexpipetolength.

6. Slidethetrimringontotheflexfortheinsidewallportion.7. Slidetheotherendofthemetalintakeflexpipethrough

the bottom shield and secure it to the shield with aminimumoftwoscrews.Theflexpipedoesnotmakeapositiveconnectiontotheappliance,itwillsupplyoutsideairasaproximitysource.

8. Securethetrimringinplaceforfinishingtheinsidewallarea.

9. Sealaroundtherodentscreenontheexteriorwall,usingsiliconecaulking.

OutsideAirKnockout

Neverdrawoutsidecombustionairfrom:• Wall,floororceilingcavity.• Enclosedspacesuchasanatticorgarage

7 Appliance Set-Up

CAUTION!

Page 17: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

17Do Not Burn Wet Coal!

Super-Magnum Coal Stoker Stove

3-90-02702R8_11/13

B. Leveling the ApplianceToadjustthelevelingbolts,youmustfirstloosenthelockingnut.Turn the leveling bolt to the desired position, and retightenthelockingnutagainstthecastironleg.

C. Optional Heat Transfer KitThe duct piping must be of metal construction in accordance with NFPA 90B, 2-1.1, and 2-1.3.1. Lift and remove the round cover from the top of the

SuperMagnum.2. Install the 6" duct pipe starting collar into the round

opening. Reaching down through the starting collar,bendthetabsupwardtosecurethecollartothestove.

3. Attachyour6"duct,comingfromaheatregisterlocateda minimum of 17 ft.away,tothestartingcollar.Securetheduct to thestartingcollarwithaminimumof threescrews.

4. Maintain a minimum of 1" clearance to combustiblematerialswiththeentirelengthofduct.

5. Ifmaximumheattransfertotheductisdesired,replacetheair grill, from the frontof the stove,with thecoverplatefromthekit.(SeePage18)

FOR YOUR SAFETY-At17to21feetofductlength,the1/2inchtabMUSTberemovedfromthetopoftheplate.At21feetormore,thecoverplatecanremainsolid,allowingalloftheheatedairtoflowthroughtheductpipe.

D. Air FilterTo ensure cleanliness of the air circulated through the heat exchange, the Super Magnum is equipped with areplaceablefilter.Thefilter is locatedunder thestove.Toremovethefilter,loosenthetwothumbscrewsandremovethecover.Slidethefilterout theopenslots in thefrontofthe channel. Checkthefilterfordamage,changeifnecessary.ReplacementfilterscanbeobtainedthroughyourHarman®dealer,orfrommosthardware,orbuildingsupplycenters.Besuretoturnthebloweroffpriortochanging

E. Optional Decorative Tile KitTo install the optional ash door tile, you'll first need tounassembletheashdoor.1. Laytheashdoor,facedown,onaflatworkspace.2. Removethefourscrewswhichholdthefillerplate into

the door.3. Laythefillerplateandscrewsaside,andlaythetileinto

place on the door assuring that the tile is centered on thegasket.

4. Applytheselfadhesivegasketontothebacksideofthetile.

5. Withthefillerplateflippedoverfromitsoriginalposition,itnowbecomesthebackerforthetile.Attachusingthefour screws.

Break-away tab for duct lengths between 17 &21 feet.

Do not connect this appliance to the supply duct of an existing furnace. This option is intended for use with a single heat register.

Thumb Screws

Filter Cover

Filter

3-43-02730 ASH DOOR TILE

3-30-3110240382BHSCS 10-24 X 3/8"

AD FILLER PLATE

3-44-11862 3/8" GASKET W/PSA

ASH DOOR

Page 18: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

18

Super-Magnum Coal Stoker Stove

Do Not Burn Wet Coal! 3-90-02702R8_11/13

F. Optional Door Trim KitThe door trim kit includes a brushed stainless frame foreachdoor,andanairgrill.Toinstalltheoptionaldoortrim,you'll first need to remove the latchmechanism from thedoor.Theprocessisthesameforeachdoor.

1. Using a hex key wrench, loosen the set screw at thelatch.Removethelatchpinandlatchhandle.

2. Removethedoorfromstove.Laythedoorfacedownonasoftmaterial.

3. Locatethefourdrilldimplesontheinsidecornersofthedoor.Usingbitsupplied(1/4”),drillaholethrougheachcorner.(twolocationsonashdoor)

4. Insertthedoortrimstudsthroughtheholes.Usinganutdriver, secure with the supplied nuts. These nuts areplaced on the stud with the indented triangle side facing up.Before tightening thenuts,check that the frame isproperlynestedintotheoffsetofthedoor.Donotover-tightennuts.Theframemaydistortorthestudcanbreakloosefromtheframeifover-tightened.

5. Place door back on the stove. Attach the latch byreversingStep1.

To Install the air grill, remove the existing painted grill.Then, using the same two screws and spring washers,installthebrushedstainlessgrill.

G. Room Sensor InstallationAlthough not required, it is recommended that the roomsensorbeconnectedineveryinstallation.Usingaminimumsize18gaugewire,youmayspliceinanadditionallength,toextendtheroomsensor.Thefollowingaretypicallocationsfortheroomsensor;• Onan interiorwallnext toor inplaceofa typicalwall

thermostat.• Onthelegofacoffeetableorendtableinyourfavorite

sitting location.• Dangledbehindthestove,hiddenfromview,actingasa

return air sensor.Note: When installing the room sensor, limit the distance from the stove to 25 feet or less. Oncethelocationhasbeendecided,runthewiringtotherearofthestove.Crimpthetwofemaleterminalsontotheendsofthewiresandplugthemintotheportprovidedonthe right rear portion of the stove. These connections are notpolarityspecific.Note: If the room sensor is located too close to the appliance, or in a direct path of the distribution air, You may need to elevate the temperature setting to maintain a comfortable temperature level throughout the heated space.

RoomSensorattaches on rear of stove.

SetScrew

Lockingnuts

Page 19: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

19Do Not Burn Wet Coal!

Super-Magnum Coal Stoker Stove

3-90-02702R8_11/13

A. Fuel SpecificationsThe Super Magnum is designed for use with Anthracite"Rice"coalOnly.Anthracite isahardcoalwhich isminedmostly in the Eastern United States. The post-miningprocessinvolvesbreakingthelargelumpsofanthraciteintosmaller,usablesizedpieces. Inthebreakingprocess, thecoal is sifted and sorted by different sized screens. Ricesize isbasicallydefinedas thecoal thathasamaximumsizeof3/8"andaminimumsizeof3/16".Mostcoalsupplierswashthecoaland/orwetitfordelivery,to keep the dust minimized. However, the coal must bedry when loading it in the stove. Therefore, it is highlyrecommended thatyoupurchaseyourcoalwellaheadoftheheatingseason,toallowittimetodry.Coal,whetherinbagsorinbulk,shouldbestoredinadryarea.

B. General Operating InformationTheSuperMagnum'sESPcontrolwillmaintainanoutputlevel to fit your temperature demands. There are twomodesofoperation;"StoveTemp"mode,wherethecontrolwillmaintainaspecifiedconstant temperature, regardlessof the surrounding environment temperature conditions,Or "RoomTemp"mode,where thecontrolwilladjust therateofburntomeetaspecifiedroomtemperaturesetting.Regardless of themode selected, operation is controlledbyboth,exhaust temperature-beingreportedbytheESP(Exhaust Sensing Probe), and themicroprocessor circuitboard.We'lldiscussthesecontroldevicesandtheirfunctionsnow.

1. ESP (Exhaust Sensing Probe)TheESPisatinythermistorlocatedintheexhauststream.Theprobechangesit'sthermalresistancebasedonminutechanges in temperature,which ismonitoredby thecircuitboardandusedtodeterminetheneedforchangesintheburnratetomeetthetemperaturedemand.

CAUTION: Approved for use with coal only. The use of any other fuel, except for the purpose of igniting the coal, will void the product warranty and may cause damage to the appliance and/or your home.

NOTICEFreshlydeliveredcoaliswatereddowntoeliminatedustwhenloadingandunloading.Wetricecoaldoesnotflowaswellasdampordrycoal.Wedonotrecommendburningwetcoal,however,werealizeifit'stheonlycoalyouhaveitisbettertoburnitthantobecold.Ifyoumustburnwetcoal, the feedratemayneed increased inorder togetthesamesizefire.Doingthisonceortwiceayearwillnotdamageyourstoveaslongasitishotandburning.Thedamageiscausedwhenthehopperhaswetcoalinwhilethe stove is not in use. This will cause rust and corrosion whichisnotcoveredbyyourwarranty.

8 Operating Instructions

WARNING!NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS TO START OR "FRESHEN UP " A FIRE IN THIS HEATER. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IN USE.

WARNING!ROUTE POWER CORD AWAY FROM THE APPLIANCE. DO NOT RUN THE CORD UNDER OR IN FRONT OF THE APPLIANCE

Page 20: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

20

Super-Magnum Coal Stoker Stove

Do Not Burn Wet Coal! 3-90-02702R8_11/13

Status Light Error Messages3-Blinks: IndicatesthattheESPhasgoneoutofrangetoomanytimes.Couldbeanindicatorofbuildupofash,etc.inthefluepipeorheatexchange.PerformaManualReset.4-Blinks: Indicates that the room sensor circuit is notcomplete. May mean a poor connection or short in thesensorwire.(Willonlyoccurin"RoomTemp"mode.)Manual Reset: Turn the mode selector to "OFF", anddisconnectpowerforasecond.Restorepowerandreturnto original setting.

Circuit Board Dipswitches: Onthefaceofthecircuitboard,there isablockof8switches.These "ON-OFF"switchesareusedtosetthetimesandtemperaturesforthedifferentmodelsofstove.Forthismodel,switchesnumbered5,7and8shouldbeon,withtherestofthemoff.NEVER ADJUST THESE SWITCHES YOURSELF, AS SERIOUS ISSUES COULD DEVELOP.Also know that if there is a need to

replace anESP probe, a switchchangemay also be needed. Itisstronglyrecommendedtohavea trained service representative makeanyrepairstotheappliance.

2. Circuit BoardAsstatedpreviously,thecircuitboardisamicroprocessor,whichmeansithastheabilityto"think"andadjustitselfbasedonbothreportedtemperaturesanddemandtemperature.Thecircuitboardalsohastheabilitytoself-diagnosewhenthingsarenothappeningastheyshouldbe.

Feed adjusterSets the maximum feed rate

TestRuns all motors at full speed for one minute to check operation. After two minutes the stove will go to minimum burn and the blowers will alternate from high to low every minute to remind you that you are still in "Test Mode".

Distribution Blower speed adjustment range. L = lowH = highVariable speed anywhere between L and H; although as the stove temp. goes up, so does the low end of the scale.

Temperature Dial;Allows you to adjust the room temperature in Room Temp Mode using the outer scale marked in degrees Fahrenheit. It also allows you to adjust the stove temperature while in Stove Temp Mode using the inner scale marked from 1 to 7.

Mode Selector Al lows you to choose between Room Temp Mode, Stove Temp Mode, or OFF. Also allows you to vary the distribution blower speed by turning the knob to the high or low side of each mode.

Power LightIndicates power to the control.

Indicates power to the feed motor.

Indicates power to the combustion blower

Status LightWill be lit in either stove or room temp mode when pointer is not within off position band except after normal shut down. Blinks to indicate errors listed below.

Indicates power to the distribution blower.

Dealer Diagnostic PortFor dealer maintenance only. Requires special DDM monitor supplied to Harman® Dealers exclusively.

Page 21: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

21Do Not Burn Wet Coal!

Super-Magnum Coal Stoker Stove

3-90-02702R8_11/13

a. Feed Rate AdjustmentTheCircuitboardrunsonaoneminutetimercycle.Eachminute,theboardisthinkingaheadtowhatitneedstodofor thenextminute tomaintainorachieve thedemandedtemperature.Whatyouaresettingonthefeedadjusterdialisthemaximumamountoffeedtime,perminute,thatyou'llallow.Thecircuitboardwillmakeitsowndeterminationofhow long to run the feeder, UPTO themaximum as seton thedial.For instance,anumber4settingon the feedadjusterwillallowamaximumof40secondsperminuteoffeed.Iftheroomtemperatureissatisfied,withonlyfeeding20 seconds, then that is all the circuit boardwill run thefeeder. Inmost tested scenarios, thenumber 4 setting isadequate, however, fuel quality may dictate a higher orlowersetting. If youseeun-burnedorburningcoalbeingpushedoffof thegrateduringahighdemandperiod, thefeed rate isset toohigh. Ideally, you'llwant toseeaboutaninchofashesinfrontoftheburningcoalduringapeakdemandperiod.Settingthefeedratetoolowmaynotallowthedemandtemperaturetobemet.Keepingthesettingat#4or abovewillworkwithmost batchesof coal.Allowaminimumofonehourbetweenadjustments.Note: Since the circuit board is feeding as needed, only adjust the feed rate while maximum demand is occurring. (Stove Temp Mode, with a temp dial setting of #7 will create maximum demand.)

b. Mode SelectionRoom-Temp mode is the ideal mode of operation if youwish tomaintainacomfortable temperature in the room.Astheoutdoortemperaturefluctuates,theSuperMagnumwilladjustthefeedratetomaintainthedesiredtemperaturesettingintheroom.Forbestresults,besuretheroomsensoris located outside of any drafty areas and not positioned on thefloorornearanexteriorwall.Stove-Tempmodeismoreofamanualmethodofoperation.Thestovewillrunataconstantheatoutput,regardlessofoutsideairtemperature.Notethatonthecoldestdays,yourindoor heated space will be cooler than on the warmerdays.Theonlyrealbenefittothismodeofoperationisthatyou'llbeabletoknowexactlyhowlongahopperfullofcoalwilllast,becausetheconsumptionisgoingtostayrelativelythesame.

c. Temperature DialThetemperaturedialisadualpurposedial.InRoom-Tempmode,youselecttheroomtemperatureyouwantthestovetomaintain at the room sensor probe. This ismarked infahrenheit scale from 50 to 90 degrees. In Stove-Tempmode,youselectatemperaturesettingbasedonthe#1-7with1beingaminimumburnand7beingamaximumburnrate.

d. Blower Speed AdjustmentThemodeselectorisalsomarkedwithaLtoHscale,ineachmode.This isavariablespeedcontrol for thedistributionblower.L is the low setting, andH is the high setting. Itis important tonote that theblowerwillnotcomeonuntiltheESPreachesahighenoughtemperaturetoensurethatcoldairisnotbeingblownoutintotheroom.Also,thespeedoftheblower,whensetonlowerspeeds,willautomaticallyincreaseasthetemperatureofthestoveincreases.Keep Hopper Lid, Ash Pan, and Fire viewing doors closed while in operation. Maintain all door seals and gaskets in good condition. Replace gaskets when necessary using parts obtianed through your Harman® dealer.Burning with one or more of the unit doors open will lead to overfiring which could damage the appliance, chimney, or connector, or could cause a house fire.

Page 22: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

22

Super-Magnum Coal Stoker Stove

Do Not Burn Wet Coal! 3-90-02702R8_11/13

C. Before Your First Fire• Be sure the appliance is installed properly and that

allsafetyrequirementshavebeenmet.Payparticularattention to the clearances to combustibles, floorprotection and the venting instructions.

• Testyoursmokedetector(s)andCOdetector(s)tothespecificationsofthemanufacturer.

• Doublecheckthattheashpanandinternalfireboxareempty.

• Besuretoreadthisentiremanual.

D. Starting Your First Fire1. With themodeselector in the "OFF"position, and the

FeedAdjusterNOTon"Test",plugthepowercordintoaproperly grounded receptacle.

2. FillthehopperwithDRYcoal.3. Placesomecoalon theburngrate,filling thevalley in

theback.4. Turnthemodeselectordialtothedesiredmode.If Room

Temp is selected, be sure to turn the temperature dial above the current room temperature.

5. Filltherestofthegrateswithamixtureofwoodpellets,ricecoal,andstartinggel.

6. Lightthestartinggelwithamatch,andclosethedoor.7. OnlyaftertheESPtemperatureincreases,willthefeeder

startoperatingtoincreasethefiresize.NEVER APPLY STARTING GEL TO THE STARTINGMIXTURE WITHOUT THE COMBUSTION BLOWEROPERATING.

"NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS TO START OR "FRESHEN UP " A FIRE IN THIS HEATER. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IN USE".

E. Fire CharacteristicsAfterlightingthefire,itwillgothroughafewdifferentstagesofappearance.First,becauseofthewoodpelletsmixedin,you'llseemostlytallyellowflames.Asthewoodpelletsburnaway,andsomecoalbeginstoignite,youryellowflameswillshortenandmixwithblueflames.Afterthewoodpelletsaregoneandthecoalistheonlythingburning,you'llseemostlyblueflames,whichcanbeinvisibleinabrightlylitarea.Asthefiresettlesin,you'llhaveaboutatwoinchbandofhotburningcoalsrunningacrossthegrates.Withamaximumtemperature demand, the ideal feed rate setting will putthis bandapproximately 1-2 inchesback from theendofthe grates.Allow at least an hour of burn time betweenadjustmentstothefeedrate.

The setting above will produce continuous maximum heat output with the distribution blower at full speed.

The setting above will produce continuous medium heat output with the distribution blower at low speed.

WARNING!

Page 23: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

23Do Not Burn Wet Coal!

Super-Magnum Coal Stoker Stove

3-90-02702R8_11/13

Symptom Possible Cause Corrective Action

WithProper installation,operation,andmaintenance,yourappliancewillprovideyearsoftrouble-freeservice.Ifyoudoexperienceaproblem,thistroubleshootingguidewillassistaqualifiedpersoninthediagnosisofaproblemandthecorrectiveactiontobetaken.Thistroubleshootingguideisintendedforusebyqualifiedservicetechniciansonly.

Pluginappliance-Noresponse.

Nocurrenttooutlet.Defectivepowercord/connection.Defectivefuseoncircuitboard.Circuitboarddefective.

Checkcircuitbreakeratservicepanel.Re-connectorreplacepowercord.Replace6ampfuseonboard.Replacecircuitboard.

Fireout,nofuelongrates. Outoffuel.Wetcoalbridgedinhopper.Foreignobjectobstruction-Hopper.Foreignobjectobstruction-Feeder.Feedsystemmalfunction.

Checkhopper.Fillwithfuel.Donotloadwetcoalinhopper.Emptythehopper,searchingforobject.Withhopperemptyexaminefeedthroat.Verifyoperationofmotor,pusherarm,andpusherblock.

Fireout,gratesfulloffuel. Combustionblowerrestrictorclosed.Combustionblowerpositioning.Ashbuild-upundergrates.Failedstartingprocess.ESPfailure-temponDDMreadsabnor-mallyhighwhenstoveiscold.

Re-setrestrictorusingdraftmeter.Besurethattheblowerisinitsmount.Removegratesandcleanairchamber.Followstartupprocedure.ReplaceESP.

Unburnedorpartiallyburnedcoal in ash pan.

Blackrocksincoal.Feedratetoohigh.

Try different coal.Setfeedadjustertolowersetting.

Coalpushingoutthesidesofthegrateframe.

Clinkersinashesrestrictingflowoffuelovertheburngrates.

Re-setrestrictorusingdraftmeter.Toomuchairflowwillcausetheashestofusetogether.Wetcoalwillnotflowproperly.

Excessivefinesinfinestray. Dirtycoalsupply.Feedrestrictioncausinggrinding.

Finesscraperadjustment.

Try different coal.Removecoalfromhopperandcheckforaforeignobjectorlargepieceofcoal.Re-adjustscraper(SeePage29).

Turnedto"OFF"won'tshutdown.

Notenoughtimeallowed.

DirtyorfailedESP.

Modeselectornottrulyinthe"OFF"position.

Shut-downsequence:MinimumfeeduntilESPcools.Combustionblowershouldbeoffunlessfireisatmaximumtemp.Removeandcleanprobe.AttachDDMtomonitortemperatureandshut-downparameters.Thestatuslightwillturnoffwhentheknobisinthe"OFF"position.(unlessthereisa3blinkerrorcode.)

DistributionBlowernotoperat-ing.

RoomTemperaturedemandmet.Insuccessfulignition.

Uponmeetingtheroomtemperatureset-point,theblowerwillstop.Also,thedistributionblowerwillnotrununtiltheESPsensesahighenoughtemperaturetoensurethatthedischargedairiswarm.

9 Troubleshooting

Contact your dealerforadditionalinformationregardingoperationandtrouble-shooting.Visitwww.harmanstoves.comtofindadealer.

Page 24: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

24

Super-Magnum Coal Stoker Stove

Do Not Burn Wet Coal! 3-90-02702R8_11/13

Whenproperlymaintained,yourstovewillgiveyoumanyyearsoftrouble-freeservice.Contactyourdealertoanswerquestionsregardingproperoperation,trouble-shootingandserviceforyourappliance.Visitwww.harmanstove.comtofindadealer.Werecommendannualservicebyaqualifiedservice technician.

A. Shut-down ProcedureThebestwaytoshutdowntheapplianceistosimplyletitrunoutoffuel,andshutdownnaturallyasthetemperaturecools.Thismethod ishighly recommended for theendofseasonshut-down.To shut-downotherwise, turn themode selector to "OFF'verifybyensuringthattheStatuslightgoesout.Theshut-downprotocolof thecircuitboardwillsafelyallowthefireto go out.

B. Quick Reference Maintenance Chart

Cleaning or Inspection Frequency Daily Weekly Monthly YearlyAreabeneathfiregrates Aftereachtonburned OR XAshremoval Wheneverfillingtheunithopper OR X

CombustionblowerMorefrequentlydependingonsurroundings OR X

Distributionairfilter Replaceasneeded OR X

DistributionblowerMorefrequentlydependingonsurroundings OR X

Doorlatchinspection Priortoheatingseason OR XFinestray Dependingonfuelquality OR XFirebox/thoroughcleaning Endofheatingseason OR X

Glass Whenveiwoffirebecomesobstructed OR X

Heatexchanger/Chainscraper Wheneverfillingtheunithopper OR XHopper Wheneveraddingfuel OR X

VentingsystemMorefrequentlydependingonfuelquality and quantity OR X

Soot Formation and Need For Removal-When coal isburned,theproductsofcombustioncombinewithmoisturetoformasootresiduewhichaccumulatesonthefluelining.When ignited, this sootmakesanextremelyhot fire.Thechimney and chimney connector should be inspected atleast once every two months during the heating seasonto determine if a soot buildup has occurred. If soot hasaccumulated,itshouldberemovedtoreducetheriskofachimneyfire.If you experiance a chimney fire;Removeallburningfuelfromthegratebyscrapingitintotheashpan.Movetheashpan safely outside the homeand place it on the ground,wellawayfromanycombustibles.Turnthecontrolto"Off"andnotifythefiredepartment.Donotoperatetheapplianceuntilthechimneyandconnectorhavebeeninspectedandapprovedbyachimneyprofessional.

10 Service & Maintenance

Page 25: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

25Do Not Burn Wet Coal!

Super-Magnum Coal Stoker Stove

3-90-02702R8_11/13

2. Heat Exchanger Chain Scraper• Frequency:Daily• By:UserWear Gloves To PerformWheneveraddingcoaltothehopper,taketheopportunitytocleantheheatexchangersurfaces.Afterall,thecleanerthesurface,thebettertheheattransfercapability.

C. General Maintenance Procedures1. Ash Removal• Frequency:Daily• By:UserWear Leather Gloves To Prevent Skin Burns!Opentheashremovaldoorby liftingupwardon the latchhandle,thenswingthedooropen.Pulltheashpanoutofthefirebox,usingtheliponthefrontofthepan.Oncetheashpanisremovedfromthestove,youcanflipthecarryhandle up for convenience.

Ashes must be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a non-combustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled. Do not use the ash container for other debris or yard waste.

Removethehopper lidandsetaside.Graspthecleaningscraperknobandpullittowardthebackofthehopper.Pushtheknobbackin,towardthefrontofthehopper,andrepeatafewtimes.Thismotiondragsachainacrosseachoftheheat exchange surfaces, andwill knock any loose ashesdown into the ash pan.

Page 26: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

26

Super-Magnum Coal Stoker Stove

Do Not Burn Wet Coal! 3-90-02702R8_11/13

3. Fines Tray Emptying• Frequency:Weekly• By:UserWear Gloves To PerformFinesaresmalldust-likeparticleswhichfall fromthefeedsystemduringoperation.Dependingonthefuelbeingused,thistraymayneedemptiedmorefrequently.Opentheleftrearaccessdoorandremovethefinestraybyslidingitout.Ifthetrayover-flowed,vacuumthefinestrayareapriortore-inserting the tray.Thesefinescanbedisposedofwithyourhouseholdgarbage.

Finestray(removed)

4. Door Glass• Frequency:Asneeded/Weekly• By:UserWhenever the view of the fire is obstructed, or weekly,cleantheglassusingasoftclothdampenedwithstandardhousehold glass cleaner. Never spray glass cleaner directly onto hot glass. Apply the cleaner to the cloth then wipe the glass.Fly-ash allowed to accumulate on the glass may lead to permanent fogging or "crazing" of the glass. Inspect the glass and sealing gasket.Replace gasket asneeded. Do not operate the stove with a broken glass.Replacement glass, which is ceramic glass, should beobtainedthroughyourHarman®dealer.Toreplaceabrokenglass;firstbesuretocarefullyremovethebrokenglassandanyremainingshardsorpieces.Withthe door laying ona flat surface, lay the gasketted glasspanelontothedoorandbesureitisproperlyfittedintothechannel. Lay the glass retainer clips in place near eachcorner,andsecurethemusingthe3/8"screws.Besuretotighteneachscrewequallysoyoudon'tcreateapressurepoint on the glass.

Warning: Do not abuse glass by striking or slamming the door closed. This type of breakage is not covered by the product warranty.

GlassRetainerscrews

GlassPanel

Gasket

GlassRetainers

DoorFrame

Page 27: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

27Do Not Burn Wet Coal!

Super-Magnum Coal Stoker Stove

3-90-02702R8_11/13

5. Air Filter• Frequency:Monthly• By:UserFilter replacement is recommended every month. Followthestepsbelowtoremovethefilter.Turn the mode selector to "OFF" to stop the blower from operating.• Locateandloosenthetwothumbscrewsthatholdthe

filterretainerinplace.• Slidethefilterretainerdownwardandremoveit.• Withtheretainerplateremoved,slidethefilterstraight

outthroughthefrontofthestove.Filtersizeis16X16X1inches.

6. Hopper• Frequency:Asnecessary/Yearly• By:UserWhenever the hopper is low or empty, take the time toinspect the hopper throat area for any larger pieces of coal orforeignobjects.Thisisalsoagoodtimetovacuumanycoalresidueordustfromthehopper.Remember to empty and clean the hopper at the end ofthe burn season or whenever the stove is not going tobeoperated fora fewdays.Thiswillhelp toprevent rustformationinthehopperandfeedsystem.

7. Firebox• Frequency:Asnecessary/Yearly• By:UserCleaningthefireboxandinternalheatexchangesurfacesisrecommendedtomaintainthermalefficiency.Dependingonthequalityandquantityofcoalbeingused,youmaywanttoperformthiscleaningmonthly.Be sure to clean these areas thoroughly at the end of the heating season.Brushandvacuumallinternalsurfaces.Liftthegratesandthoroughlyclean theair flowareaunder thegrates. (Seedrawingbelow).

Thiscrosssectionalcut-awayillustrationshowsaninternalviewoftheheatexchange,plusyoucanalsoseehowthegratesareremovedbyliftingthemoutoftheframe.

Thumb Screws

Filter Cover

Filter

Page 28: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

Super-Magnum Coal Stoker Stove

Do Not Burn Wet Coal! 3-90-02702R8_11/13 28

8. Chimney Connector• Frequency:Asnecessary/Yearly• By:QualifiedServiceTechnician/UserAttheendoftheburnseason,brushandcleanallsectionsof chimney connector pipe. Some owners remove thechimneyconnectorfor theoffseason.Anycoalashesleftin the connector pipe will actually draw moisture whichpromotesrust.This iswhy it isvery important tocleanallashes at the end of the heating season. 9. Chimney• Frequency:Asnecessary/Yearly• By:QualifiedServiceTechnician/ChimneySweepThe entire chimney should be professionally cleaned atleastonceyearly.Itisbesttohavethisdoneattheendoftheheatingseasontobesureallashisremoved.You'llalsowanttoinspecttheconditionofthechimneypriortousingtheappliance,tobesuretherearenobirdnestsorthelike.D. Motors and Components1. Feed MotorRequiresnolubrication.Keepthemotorwindingsfreeofdust.Canbewipedcleanorvacuumed.Toremovefeedmotor;• Removerearaccesspanelandopenleftreardoor.• Removefeedshaftshieldbypushingwiththumbwhere

shown,andliftupwhilepullingout.

SetScrew

MountingScrews

2. Combustion BlowerRequiresnolubrication.Keepthemotorwindingsandintakescreenfreeofdustandpethair.Canbewipedcleanorvacuumed.Toremovecombustionblower;• Openleftreardoor.• Removewire-tiefromblowerpowercord.• Slide the blower mounting flange out of the bracket

toward the left side. NOTICE: When re-installing blower, be sure it is slidcompletelyintothemountingbracket.Thereisastopontherightsideofthebrackettoensureproperpositioning.

BlowerMountingBracket

• LocatetheAllen-headsetscrewonthefeedmotorshaftand loosen it.

• Removethe4motormountingscrewsandpullthemotoroutthroughtheleft,reardoor.

Page 29: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

29Do Not Burn Wet Coal!

Super-Magnum Coal Stoker Stove

3-90-02702R8_11/13

3. Distribution BlowerRequiresnolubrication.Changefiltermonthlytopreventbuildupofpethair,etc.Toremovedistributionblower;• Removefilterretainerandfilter.• Disconnectthethreewiresfromtheblowerpowercord.• Loosen3mountingscrewswhichholdthemotorintoits

housing.• Lowerthemotorandsquirrelcagefanoutoftheblower

housing.

4. ESP- (Exhaust Sensing Probe)Removeandwipecleanwithasoftclothandglasscleaneror alcohol.Toremovetheprobe,you'llneedtoaccessthepanelinthefuel hopper.• Remove the knob from the heat exchange scraper

handle.Theknobisthreadedontotheshaft.• Removetheaccesspanelbylooseningthescrews.• With a 1/4" socket or driver, remove the screw that

attachestheprobe.• Pulltheprobeoutofit'smountinghole.

Scraper Knob

Access Cover

ESP (probe)

5. Fines Scraper- in feederIn the base of the hopper, there is a scraper plate thatkeeps the coal fines flowing toward the fire.This scraperplate is designed to be adjustable. To adjust, loosen thetwo boltswith a 7/16"wrench, allow the scraper plate torestdownwardagainstthetopofthepusherblock,andre-tightenthetwobolts.

MountingScrews(3)

THIS vIEW IS LOOKING STRAIGHT DOWN INTO THE HOPPER. LOOSEN THESE TWO BOLTS TO ADJUST THE SCRAPER.

Page 30: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

30

Super-Magnum Coal Stoker Stove

Do Not Burn Wet Coal! 3-90-02702R8_11/13

120 VAC SUPPLY

TW

ISTE

D W

IRES

CON

TRO

L

THER

MO

STAT

EXT

ENSI

ON

FEED

MO

TOR

MAX

. WAT

TS 3

96 --

3.3

A. -

- 120

VO

LTS

A.C

. 60

HZ.

ROO

M S

ENSO

R

6 A

MP

GLA

SS F

USE

EXH

AUST

SEN

SIN

G P

ROBE

BOA

RD BL

ACK

WH

ITE

BLAC

K

BLAC

K

GRE

EN LABE

L PA

RT N

O. 3

-90-

0270

3

11 P

IN C

ON

NEC

TOR

WH

ITE

BLAC

K

GRE

EN

HA

RMA

N -

SUPE

R M

AGN

UM

CO

AL

STO

KER

# 1-

90-0

2700

COM

BUST

ION

FA

N

BROWN BLACK

WHITEWHITE

WHITE

BLACK

WHITE

RED

WHITE

BLUEG

REEN

GREEN

DIS

TRIB

UTI

ON

FA

N

11 P

IN C

ON

NEC

TOR

BLAC

K

WH

ITE

11 Reference Materials

Page 31: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

Service Parts Super Mag StokerBeginning Manufacturing Date: July 2009

Ending Manufacturing Date: Active

Part number list on following page.

1-90-02700-1

3433

3231

30 29

35

3738

28

2624

23

39

40

41

43 3642

20

21 22

19

18

17

1

6

7

89

5

234

27

1615

14

1312

11

10

25

11/13

Coal Stove

Page 32: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

Service Parts Super Mag StokerBeginning Manufacturing Date: July 2009

Ending Manufacturing Date: Active

IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer ordistributor.Hearth and Home Technologies does not sell directly to consumers.Provide model number and serial number when requesting service parts from your dealer ordistributor.

Stockedat Depot

ITEM Description COMMENTS PART NUMBER1 ScraperKit 1-00-027702 RearCoverRightAssemblyW/OBoard 1-10-02742A

CircuitBoardw/Knobs&Shafts 1-00-06142 Y3 HopperShieldSupportAsssembly 1-10-02724A4 RearCover 2-00-02745B5 RearCoverLeft 2-00-02728B6 1/4-20x1/2”Grade8.2ZincSAEFlangeBolt Pkgof50 3-30-2001-50 Y7 5/16-18x3/4”Grade5ZincPlatedHexCapScrew Pkgof100 3-30-1125-100 Y8 75CFMBlower22”Cord/Combustion 3-21-07522 Y9 BlowerRestrictorPlate Pkgof2 2-00-01023-210 GasketSingle-plyFeeder-Body 1-00-88100 Y11 HandleKit Qty.2req. 1-00-27713 Y12 1/4-20x1/2”Grade8.2ZincSAEFlangeBolt Pkgof50 3-30-2001-50 Y13 SteelSleeveBushing1/2”ODx3/4”HandleKit 3-50-0523014 1/4-20x11/2Grade8YellowZincHexHeadCapScrew Pkgof25 3-30-1119-25 Y15 AdjusterPlate 2-00-06713D16 1/4-20GradeCZincPlatedTopLockNut Pkgof50 3-30-8021-50 Y17 3/8-16x1”Grade5ZincPlatedHexCapScrew Pkgof50 3-30-1134-50 Y18 5/16”-18Grade5ZincPlatedFinishedHexNut Pkgof100 3-30-8005-100 Y19 OakwoodLegs Qty4req 4-00-249100P Y20 5/16-18x2”ZincPlatedCarriageBolt Pkgof25 3-30-4001-25 Y21 AshPanAssembly 1-10-02736A Y22 DoorAssembly 1-10-02748A Y

Glass 3-40-02749 YGlassGasket 15Ft 1-00-2312 YDoorGasket 30Ft 1-00-00888 Y

23 AshDoorAssembly 1-10-02763A YDoorLatch 1-00-249119 Y

24 Filter16”x16”x1” 3-40-1616125 FilterCover 2-00-02762B26 1/4-20WingScrewwithCollar Pkgof10 3-31-782108-10 Y27 BlowerAssembly 1-10-02718A

BlowerDistribution 3-21-47120 Y28 GrateHolderAssemblyW/OInserts 1-10-01000 Y

GrateInserts Qty2req 4-00-00046D Y29 1/4-20x1/2”Grade5ZincPlatedHexCapScrewPackaged Pkgof50 3-30-1108-50 Y30 1/4”-20x1/2”AlloySteelBlackOxideFlatHeadCapScrew Pkgof100 3-30-7001-100 Y

Additionalservicepartsonfollowingpage.

Page 33: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

Service Parts Super Mag StokerBeginning Manufacturing Date: July 2009

Ending Manufacturing Date: Active

IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer ordistributor.Hearth and Home Technologies does not sell directly to consumers.Providemodelnumberandserialnumberwhenrequestingservicepartsfromyourdealerordistributor.

Stockedat Depot

ITEM Description COMMENTS PART NUMBER31 1/4”-20x1/2”AlloySteelBlackOxideButtonHeadCapScrew Pkgof100 3-30-3015-100 Y32 6mmSpringWasher Pkgof25 3-31-08558-25

33 AirGrill 2-00-02726L

34 StandardFirebrick9”x4-1/2”x1-1/4” Pkgof7 1-00-900450125 Y35 AngleCutBrick-Setofcutbrick 2-00-00688 Y36 SidePanel Qty.2req. 2-00-02722B

37 BodyWeldment 1-89-02700W

38 DuctCoverWeldment 1-10-02740W

39 HopperAssembly 1-10-02733-1A Y40 ESPProbe 3-20-02778 Y41 #8-18x3/4”HexWasherHeadTEKSDrillandTap Pkgof100 3-30-5003-100 Y42 1/4-20x5/8”HexWasherSlotT23ZincThreadCuttingScrew Pkgof50 3-30-1111-50 Y

3/8”-16x1/4”AlloySteelBlackOxideCupPointSSS Pkgof25 3-30-2014-25 YAirGrill BrushedStainless 3-43-02726-7

AshDoorTileFrame BrushedStainless 3-43-02729-7

BallPlunger,5/16x1/2 Pkgof3 3-31-5500-3

BallSpringBracket 2-00-06714

Brick,Fullskid 414Pcs 3-40-900450-414

DoorHingew/Pin Qty2req 3-00-773813

DoorTrim BrushedStainless 3-43-06931-7

D-ShapeKnob/Shaft 25Sets 1-00-015605 YFemDisc-FullyIns Pkgof25 1-00-00959 YFrontDoorHandle&Bolt 1-00-00247 YFrontDoorLatch 3-00-249119P YGasketGlue,32oz 3-42-4583

Gasket,3/8RDHD 5Ft 1-00-43375 YGlassclipsw/Hardware Setof4 2-00-05202-4 YGround Harness 3-20-02776

Label,ControlBoard 3-90-08646

Labels,Caution&Danger 10Ea 1-00-200408541

LoadDoor 4-00-06920P

LoadDoorLatchHardware 1-00-06903

PowerCordsw/Ends 3-20-39685 YRoomSensor 3-20-00906 YThermostatExtension 3-20-00607 YThermostatProbeExtension 3-20-72225 Y

TouchUpPaint,Aerosol,BlackPre008600955 3-42-1990Post008600955 3-42-19905

WiringHarness 3-20-02775AdditionalServicePartsonfollowingpage

Page 34: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

Service Parts Super Mag StokerBeginning Manufacturing Date: July 2009

Ending Manufacturing Date: Active

IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer ordistributor.Hearth and Home Technologies does not sell directly to consumers.Providemodelnumberandserialnumberwhenrequestingservicepartsfromyourdealerordistributor.

Stockedat Depot

ITEM Description COMMENTS PART NUMBER43 FeederAssembly 1-10-02700A Y43.1 PusherBlockScraper 2-00-02772B Y43.2 PusherBlockSlideWeldment 1-10-02749W Y43.3 5/16-18x1/2”Grade5ZincPlatedHexCapScrew Pkgof50 3-30-1122-50 Y43.4 PusherArmWeldment 1-10-02708W Y43.5 5/16”-18Grade5ZincPlatedFinishedHexNut Pkgof100 3-30-8005-100 Y43.6 PillowBlock 3-31-324122 Y43.7 1/4”-20ZincPlatedFinishedHexNut Pkgof100 3-30-8004-100 Y43.8 HCS1/4-20X1/2” Pkgof50 3-30-1108-50 Y43.9 SHShoulderScrew5/16-18X3/8”X3/8” 3-30-13118075943.10 PusherBlock 3-50-02777 Y43.11 FinesTray 2-00-02746B Y43.12 Washer-1/4”ContactSpring Pkgof10 3-30-0300252-1043.13 FeederCleanoutSlide 2-00-00048P Y43.14 FeederWeldment 1-10-02701W YAdditionalServicePartsonfollowingpage

#43 Feeder Assembly

43.1

43.3

3

43.243.4

43.543.6

43.743.8

43.9

43.10

43.11

43.12

43.7 43.13

43.14

Page 35: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

Service Parts Super Mag StokerBeginning Manufacturing Date: July 2009

Ending Manufacturing Date: Active

IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer ordistributor.Hearth and Home Technologies does not sell directly to consumers.Providemodelnumberandserialnumberwhenrequestingservicepartsfromyourdealerordistributor.

Stockedat Depot

ITEM Description COMMENTS PART NUMBER44 MotorMountAssembly 1-10-02760A Y44.1 CamBearing 3-31-301444.2 5/16”-18x3/8”AlloySteelBlackOxideKnurledPointSSS Pkgof25 3-30-2004-25 Y44.3 5/16-18ZincPlatedSquareNut Pkgof50 3-30-8025-50 Y44.4 5/16-18x1/2”Grade5ZincPlatedHexCapScrew Pkgof50 3-30-1122-50 Y44.5 LaserCamAssembly 1-10-02764A Y44.6 PillowBlock 3-31-324122 Y44.7 5/16”-18Grade5ZincPlatedFinishedHexNut Pkgof100 3-30-8005-100 Y44.8 ExtensionShaft 2-00-02706 Y44.9 BackCover 2-00-02705B44.10 WireCover 2-00-02773B44.11 Grommet7/16”IDX3/4”OD 3-31-96002144.12 HWHTCS10-24X3/4BLACKOXTYPEF Pkgof50 3-30-1102-50 Y44.13 PelletFeederGearmotor-4RPM 3-20-60906 Y44.14 CordClamp 3-20-1240244.15 #10ExternalToothlockWasher Pkgof100 3-30-0001-100 Y44.16 22”PowerCordFeedMotor 3-20-29523 Y

MaleDisconnect(PowerCord) Pkgof25 1-00-00957 YGearmotorBlade Pkgof3 3-20-2046399-3 YRingTerminal(PowerCordGreen) Pkgof25 1-00-01003 Y

#44 Motor Mount Assembly

44.144.2

44.344.444.5

44.6

44.7

44.844.9

44.10

441144.12

44.13

44.14

44.16

44.15

Page 36: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

4021-645F02-18-13 Page1of2

Hearth & Home TechnologiesLIMITED LIFETIME WARRANTY

Hearth&HomeTechnologies,onbehalfofitshearthbrands(”HHT”),extendsthefollowingwarrantyforHHTgas,wood,pellet,coalandelectrichearthappliancesthatarepurchasedfromanHHTauthorizeddealer.

WARRANTY COVERAGE:HHTwarrantstotheoriginalowneroftheHHTapplianceatthesiteofinstallation,andtoanytransfereetakingownershipoftheapplianceatthesiteofinstallationwithintwoyearsfollowingthedateoforiginalpurchase,thattheHHTappliancewillbefreefromdefectsinmaterialsandworkmanshipatthetimeofmanufacture.Afterinstallation,ifcoveredcompo-nentsmanufacturedbyHHTarefoundtobedefectiveinmaterialsorworkmanshipduringtheapplicablewarrantyperiod,HHTwill,atitsoption,repairorreplacethecoveredcomponents.HHT,atitsowndiscretion,mayfullydischargeallofitsobligationsundersuchwarrantiesbyreplacingtheproductitselforrefundingtheverifiedpurchasepriceoftheproductitself.Themaximumamountrecoverableunderthiswarrantyislimitedtothepurchasepriceoftheproduct.Thiswarrantyissubjecttoconditions,exclusionsandlimitationsasdescribedbelow.

WARRANTY PERIOD:Warrantycoveragebeginsonthedateoforiginalpurchase.Inthecaseofnewhomeconstruction,warrantycoveragebeginsonthedateoffirstoccupancyofthedwellingorsixmonthsafterthesaleoftheproductbyanindependent,authorizedHHTdealer/distributor,whicheveroccursearlier.Thewarrantyshallcommencenolaterthan24monthsfollowingthedateofproductshipmentfromHHT,regardlessoftheinstallationoroccupancydate.Thewarrantyperiodforpartsandlaborforcoveredcomponentsisproducedinthefollowingtable.Theterm“LimitedLifetime”inthetablebelowisdefinedas:20yearsfromthebeginningdateofwarrantycoverageforgasappliances,and10yearsfromthebeginningdateofwarrantycoverageforwood,pellet,andcoalappliances.Thesetimeperiodsreflecttheminimumexpectedusefullivesofthedesignatedcomponentsundernormaloperatingconditions.

Seeconditions,exclusions,andlimitationsonnextpage.

Parts Labor Gas Wood Pellet EPAWood Coal Electric Venting

X X X X X X X

AllpartsandmaterialexceptascoveredbyConditions,

Exclusions,andLimitationslisted

X X X Igniters,electroniccomponents,and glass

X X X X X Factory-installedblowersX Moldedrefractorypanels

X Firepotsandburnpots

5years 1year X X Castingsandbaffles

7years 3years X X X Manifoldtubes,HHTchimneyandtermination

10years 1year X Burners,logsandrefractory

LimitedLifetime 3years X X X X X Fireboxandheatexchanger

X X X X X X X Allreplacementpartsbeyondwarrantyperiod

WarrantyPeriod HHTManufacturedAppliancesandVenting

1Year

ComponentsCovered

3years

2 years

90Days

Page 37: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

4021-645F02-18-13 Page2of2

WARRANTY CONDITIONS:• ThiswarrantyonlycoversHHTappliancesthatarepurchasedthroughanHHTauthorizeddealerordistributor.Alistof

HHTauthorizeddealersisavailableontheHHTbrandedwebsites.• ThiswarrantyisonlyvalidwhiletheHHTapplianceremainsatthesiteoforiginalinstallation.•ThiswarrantyisonlyvalidinthecountryinwhichtheHHTauthorizeddealerordistributorthatsoldtheappliance

resides.• Contactyourinstallingdealerforwarrantyservice.Iftheinstallingdealerisunabletoprovidenecessaryparts,contact

thenearestHHTauthorizeddealerorsupplier.Additionalservicefeesmayapplyifyouareseekingwarrantyservicefromadealerotherthanthedealerfromwhomyouoriginallypurchasedtheproduct.

• Checkwithyourdealerinadvanceforanycoststoyouwhenarrangingawarrantycall.Travelandshippingchargesforpartsarenotcoveredbythiswarranty.

This warranty is void if:• Theappliancehasbeenover-firedoroperatedinatmospherescontaminatedbychlorine,fluorine,orotherdamaging

chemicals.Over-firingcanbeidentifiedby,butnotlimitedto,warpedplatesortubes,rustcoloredcastiron,bubbling,crackinganddiscolorationofsteelorenamelfinishes.

• Theapplianceissubjectedtoprolongedperiodsofdampnessorcondensation.• Thereisanydamagetotheapplianceorothercomponentsduetowaterorweatherdamagewhichistheresultof,but

notlimitedto,improperchimneyorventinginstallation.

LIMITATIONS OF LIABILITY:• Theowner’sexclusiveremedyandHHT’ssoleobligationunderthiswarranty,underanyotherwarranty,expressor

implied,orincontract,tortorotherwise,shallbelimitedtoreplacement,repair,orrefund,asspecifiedabove.InnoeventwillHHTbeliableforanyincidentalorconsequentialdamagescausedbydefectsintheappliance.Somestatesdonotallowexclusionsorlimitationofincidentalorconsequentialdamages,sotheselimitationsmaynotapplytoyou.Thiswarrantygivesyouspecificrights;youmayalsohaveotherrights,whichvaryfromstatetostate.EXCEPTTOTHEEXTENTPROVIDEDBYLAW,HHTMAKESNOEXPRESSWARRANTIESOTHERTHANTHEWARRANTYSPECIFIEDHEREIN.THEDURATIONOFANYIMPLIEDWARRANTYISLIMITEDTODURATIONOFTHEEXPRESSEDWARRANTYSPECIFIEDABOVE.

WARRANTY EXCLUSIONS:Thiswarrantydoesnotcoverthefollowing:• Changesinsurfacefinishesasaresultofnormaluse.Asaheatingappliance,somechangesincolorofinteriorand

exteriorsurfacefinishesmayoccur.Thisisnotaflawandisnotcoveredunderwarranty.• Damagetoprinted,plated,orenameledsurfacescausedbyfingerprints,accidents,misuse,scratches,melteditems,

orotherexternalsourcesandresiduesleftontheplatedsurfacesfromtheuseofabrasivecleanersorpolishes.• Repairorreplacementofpartsthataresubjecttonormalwearandtearduringthewarrantyperiod.Theseparts

include:paint,wood,pelletandcoalgaskets,firebricks,grates,flameguides,batteriesandthediscolorationofglass.• Minorexpansion,contraction,ormovementofcertainpartscausingnoise.Theseconditionsarenormalandcom-

plaintsrelatedtothisnoisearenotcoveredbythiswarranty.• Damagesresultingfrom:(1)failuretoinstall,operate,ormaintaintheapplianceinaccordancewiththeinstallation

instructions,operatinginstructions,andlistingagentidentificationlabelfurnishedwiththeappliance;(2)failuretoinstalltheapplianceinaccordancewithlocalbuildingcodes;(3)shippingorimproperhandling;(4)improperopera-tion,abuse,misuse,continuedoperationwithdamaged,corrodedorfailedcomponents,accident,orimproperly/incorrectlyperformedrepairs;(5)environmentalconditions,inadequateventilation,negativepressure,ordraftingcausedbytightlysealedconstructions,insufficientmake-upairsupply,orhandlingdevicessuchasexhaustfansorforcedairfurnacesorothersuchcauses;(6)useoffuelsotherthanthosespecifiedintheoperatinginstructions;(7)installationoruseofcomponentsnotsuppliedwiththeapplianceoranyothercomponentsnotexpresslyauthorizedandapprovedbyHHT;(8)modificationoftheappliancenotexpresslyauthorizedandapprovedbyHHTinwriting;and/or(9)interruptionsorfluctuationsofelectricalpowersupplytotheappliance.

• Non-HHTventingcomponents,hearthcomponentsorotheraccessoriesusedinconjunctionwiththeappliance.• Anypartofapre-existingfireplacesysteminwhichaninsertoradecorativegasapplianceisinstalled.• HHT’sobligationunderthiswarrantydoesnotextendtotheappliance’scapabilitytoheatthedesiredspace.Informa-

tionisprovidedtoassisttheconsumerandthedealerinselectingtheproperappliancefortheapplication.Consider-ationmustbegiventoappliancelocationandconfiguration,environmentalconditions,insulationandairtightnessofthe structure.

Page 38: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

38

Super-Magnum Coal Stoker Stove

Do Not Burn Wet Coal! 3-90-02702R8_11/13

Service & Maintenance LogDate Of Service Performed By Description Of Service

Page 39: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

39Do Not Burn Wet Coal!

Super-Magnum Coal Stoker Stove

3-90-02702R8_11/13

Service & Maintenance LogDate Of Service Performed By Description Of Service

Page 40: Care and Operation - Hearth N Home4 uperagnu oal toer tove Do Not Burn Wet Coal! 3-90-02702R811/13 A. Appliance Certification

Proudly Printed On 100% Recycled Paper

At Harman®, we build each product to a standard, not a price.

(Signature of Boxer)

Your premium quality hearth product designed and assembled by the experienced and skilled members at Harman® in Halifax, PA, USA.


Recommended