® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987e 1 02.18.19
Caséta Wireless Load ControlsThe Caséta Wireless family of dimmers, switches, and fan controls can be controlled directly and remotely when paired with Pico remote controls providing a system that delivers convenience and ease of installation.Caséta Wireless dimmers, switches, and fan controls use Lutron patented Clear Connect RF Technology which enables wireless communication with Pico remote controls and the Lutron Smart Bridge and Smart Bridge PRO.
Features
•Works with Pico Remote Control•Works with the Lutron App (via a Smart Bridge or
Smart Bridge PRO)1
•Lutron patented Clear Connect RF Technology works through walls and floors
•Includes Front Accessible Service Switch (FASS) for safe lamp replacement
•Works with Lutron Radio Powr Savr occupancy and vacancy sensors in standalone applications (sensors do not work with Smart Bridge or Smart Bridge PRO)
Caséta Wireless In-Wall Switches
Caséta Wireless In-Wall Dimmers
Caséta Wireless Plug-In Lamp Dimmer
Caséta Wireless ELV+ Dimmer
Caséta Wireless Fan Control
1 The Lutron App is required for setup and usage with the Smart Bridge and Smart Bridge PRO. The Lutron App is compatible with iOSR devices version 8.0 or later and AndroidT devices 4.0 or later.
Note: Certain models or load types will require a neutral connection (see Load Types and Capacity sections).
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987e 2 02.18.19
SpecificationsRegulatory Approvals
• cULusListed• NOMCertified• FCCApproved.ComplieswiththelimitsforaClassB
digital device, pursuant to Part 15 of the FCC Rules• IndustryCanadaCertified• IFTELCertified• NEMA410(-5ANS, -6ANS,-5WS,-10NXD,-5NE)
PowerOperating voltage:
•120V~ 50/60 Hz: -3PCL, -6WCL, -10NXD, -6ANS, -5ANS,-5NE,-FSQN
•120/277V~50/60Hz:-5WS-DV
Key Design Features• Testedtowithstandelectrostaticdischargewithout
damage or memory loss, in accordance with IEC61000-4-2.
• Testedtowithstandsurgevoltageswithoutdamageorlossofoperation,inaccordancewithIEEEC62.41-1991 Recommended Practice on Surge VoltagesinLow-VoltageACPowerCircuits.
• Loadcontrolsalwaysoperatelocallyanddonotrequire system control.
• Powerfailurememory:shouldpowerbeinterrupted,the control will return to its previously set level prior to the interruption when power is restored.
• PD-5WS-DV,PD-5ANS, PD-6ANS, and PD-10NXD use conventional 3-way wiring.
• UsesLutronClarowallplatesordesigner-stylewallplates from other manufacturers. Wallplates are sold separately.
• LutronClarowallplatessnaponwithnovisiblemeans of attachment.
• Requiresa1-gangU.S.wallbox.31⁄2 in (89 mm) depth recommended, 21⁄4 in (57 mm) depth minimum1.
• GreenstatusLED(s)toindicateloadstatus.• PD-FSQNprovides4quietfanspeedsplusOFFfora
single ceiling fan.
System Communications and Capacity• CasétaWirelessin-wallswitches,dimmers,andfan
controls communicate with Pico remote controls and the Lutron Smart Bridge/Smart Bridge PRO through Radio Frequency (RF).
• TheCasétaWirelessin-wallswitches,dimmers,andfan controls communicate with Lutron Radio Powr Savr cccupancy and vacancy sensors in a standalone application. Sensors do not work with Smart Bridge or Smart Bridge PRO.
• TheCasétaWirelessin-wallswitches,dimmers,and fan controls must be located within 60 ft (18 m) line-of-sight or 30 ft (9 m) through walls, of Pico remote controls and Lutron Smart Bridge devices.
Device limits• PicoremotecontrolsandRadioPowrSavr
occupancy sensors: up to 10 devices (total) may be paired to each Caséta Wireless in-wall switch/dimmer (with no Smart Bridge installed).
• SmartBridgeorSmartBridge PRO system: up to 50 total wireless devices (Caséta wireless dimmers/switches, Pico remote controls, and shades) are supported per system. Smart Bridge or Smart Bridge PRO counts as one device.
Environment• Ambientoperatingtemperature:32 °Fto104 °F
(0 °Cto40 °C),0%to90%humidity, non-condensing. Indoor use only.
• PD-5WS-DV,PD-5ANS, PD-6ANS, and PD-10NXD can be used with mechanical switch in 3-way applications.
1PD-FSQNrequires2` in (63` mm) minimum depth
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987e 3 02.18.19
PRO Dimmer
PD-10NXD
Plug-In Dimmer PD-3PCL
In-Wall Dimmer
PD-6WCL
ELV+ Dimmer PD-5NE
2-wire Switch
PD-5WS-DV
Neutral Switch
PD-5ANS, PD-6ANS
Fan Control
PD-FSQN
Simple two-wire installation (no neutral wire required)
√ 1 √ √
Capable of dimming loads √ √ √ √
Favorite button (user defined one-touch preset level)
√ √
WorkswithHi-lume1%2-WireLEDDrivers (Forward-phase only)
√ √ √ √
WorkswithPowerInterfaces(PHPMandGRX-TVI)
√ √
WorkswithPowerInterfaces(PHPM-SW) √
No wiring required √
Controls speed of a single ceiling fan √
1 In some low-wattage applications the PD-10NXD will require a neutral wire connection.
Features
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987e 4 02.18.19
Load Type and Capacity - Switches and Fan Control
Model Number Description Voltage Load Type Minimum LoadMaximum Load 3
Not Ganged End of Gang Middle of Gang
PD-5WS-DV1 Two-wire switch
120V~ Incandescent / Halogen 25 W 600 W 450 W 350 W
277V~ Incandescent / Halogen 25 W 1350 W 1100 W 800 W
120V~ MLV 25 W 600VA/475W 450VA/350W 350VA/275W277V~ MLV 25 W 1350VA/1075W 1100VA/875W 800VA/625W
120V~ GeneralPurpose Fan 0.4 A 3 A 3 A 3 A
120/277V~ LED UseLUT-MLC2 5 A 4 A 3 A120/277V~ Fluorescent UseLUT-MLC2 5 A 4 A 3 A120V~ ELV UseLUT-MLC2 600 W 450 W 350 W277V~ ELV UseLUT-MLC2 1350 W 1100 W 800 W
PD-5ANS
Neutral-wire switch (neutral connection required)
120V~
Incandescent / Halogen 10 W 600 W 600 W 600 W
MLV 10 W 600VA 600VA 600VAFan 0.1 A 3 A 3 A 3 ALED 1 bulb 5 A 5 A 5 AFluorescent 1 ballast 5 A 5 A 5 AELV 10 W 600 W 600 W 600 WPHPM-SW 1 interface 2 interfaces 2 interfaces 2 interfaces
PD-6ANS
Neutral-wire switch (neutral connection required)
120V~
Incandescent / Halogen 10 W 720 W 720 W 600 W
MLV 10 W 720VA 720VA 600VAFan 0.1 A 3.6 A 3.6 A 3.6 ALED 1 bulb 6 A 6 A 5 AFluorescent 1 ballast 6 A 6 A 5 AELV 10 W 720 W 720 W 600 WPHPM-SW 1 interface 3 interfaces 3 interfaces 3 interfaces
PD-FSQN4
Fan speed control (neutral connection required)
120V~
Single Ceiling Fan (Permanent split-capacitor motor)
0.1 A 1.5 A 1.5 A 1.5 A
1 No neutral wire required.2 ToensureproperoperationoftheswitchwithLED,fluorescent,andELVloads,aLUT-MLC(included)mayberequired,especiallyatlowerwattages.Ifthe
statusLEDontheswitchisflashingorsolidredincolor,aLUT-MLCmustbeinstalled.Toguaranteebestperformance,installingaLUT-MLCwiththeseloadtypesregardlessofwattageisrecommended.Rarely,someloadtypesmaystillflickerorglowintheoffstateevenwiththeLUT-MLCinstalled,inwhichcaseadifferentloadmayberequiredormorethanoneLUT-MLCisrequired.
3 See“GangingandDerating”section.4 Notforusewithfansthathaveintegratedfanspeedand/orlightcontrolmodules,DCmotorfans,fanswithremotecontrols,bathroomorkitchenexhaust
type fans.
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987e 5 02.18.19
1 Cannot be ganged.2 NeedtochangeloadtypetoMLV.Seewww.casetawireless.com/change_phase3 See bulb list at www.lutron.com/led4 ForPD-10NXD,aneutralconnectionisrequiredforMLVloads,LEDdrivers,dimmableballasts,andpowermodules(PHPM-PA,PHPM-3F,andGRX-TVI).5 CompatibledimmableballastsincludeTu-Wire,MarkX,andPowerSenseR.6 These loads are best operated using a forward-phase control. Consult www.casetawireless.com/bulblist to ensure the appropriate phase for bulb models used.7 SSL7 compliant when in forward-phase. 8 Canadian packaged product.9 Available in WH only.10 Kit model number. Kit includes (1) PD-3PCL-WH, and (1) PJ2-3BRL-WH-L01R (3-button with raise/lower Pico wireless control in White).11 Kitmodelnumber.Kitincludes(1)L-BDG2-WH(CasétaWirelessSmartBridgewithHomeKittechnology),(1)PD-3PCL-WH,(1)PJ2-3BRL-WH-L01R(3-buttonwith
raise/lowerPicowirelesscontrolinWhite)and(1)L-PED1-WH(SingletabletoppedestalinWhite).12 Kit model number. Kit includes (1) PD-6WCL-WH, (1) PJ2-3BRL-WH-L01R (3-button with raise/lower Pico wireless control in White), and (1) CW-1-WH (single-gang
faceplate in White).13 Kitmodelnumber.Kitincludes(1)L-BDG2-WH(CasétaWirelessSmartBridgewithHomeKittechnology),(1)PD-6WCL-WH,(1)PJ2-3BRL-WH-L01R(3-buttonwith
raise/lower Pico wireless control in White), and (1) CW-1-WH (single-gang faceplate in White).14 Kitmodelnumber.Kitincludes(1)L-BDG2-WH(CasétaWirelessSmartBridgewithHomeKittechnology),(2)PD-6WCL-WH,(2)PJ2-3BRL-WH-L01R(3-buttonwith
raise/lowerPicowirelesscontrolinWhite),(2)L-PED1-WH(SingletabletoppedestalinWhite)and(2)CW-1-WH(single-gangfaceplateinWhite).15 PROKitmodelnumber.Kitincludes(1)L-BDGPRO2-WH(CasétaWirelessSmartBridgePROwithHomeKittechnology),(1)PD-6WCL-WH,
(1) PJ2-3BRL-WH-L01R (3-button with raise/lower Pico wireless control in White) and (1) CW-1-WH (single-gang faceplate in White).
Load Type and Capacity - Dimmers
Model Number Description Voltage Load Type Minimum Load
Maximum LoadNot Ganged End of Gang Middle of Gang
PD-10NXDPD-10NXD-XX-C 8
Wireless In-Wall Dimmer PRO (neutral connection required for certain load types)4
120V~
Incandescent / Halogen10 W with neutral (25 W without neutral)
1000 W 800 W 600 W
MLVHalogen 10 W 1000VA 800VA 600VAMLVLED See Application Note #559CFL/LED(120V~ Rated)3 1 bulb3 250 W 250 W 250 W
Hi-lume1%2-WireLEDdrivers 1 driver 13 drivers 13 drivers 13 drivers
Dimmable Ballasts5 1 ballast 1000VA 800VA 600VAPHPM-PA/3FandGRX-TVI4 1 interface 3 interfaces 3 interfaces 3 interfaces
PD-3PCL1, 9
PD-3PCL-WH-C 8P-PKG1P-WH9, 10
P-BDG-PKG2P9, 11
Wireless Plug-In Lamp Dimmer
120V~
Incandescent / Halogen 10 W 300 W N/A N/A
CFL/LED(120V~ Rated)3 1 bulb3 100 W N/A N/A
PD-5NEPD-5NE-XX-C8
Phase Selectable Dimmer (neutral connection required)
120V~
Incandescent / Halogen 10 W 500 W 400 W 300 WCFL/LED (120V~ Rated)3, 6, 7 1 bulb3 250 W 250 W 250 W
MLVHalogen 2, 6, 7 10 W 400VA 400VA 400VAELVHalogen 10 W 500 W 400 W 300 WHi-lume1%2-WireLEDdrivers 6, 7 1 driver 20 drivers 20 drivers 20 drivers
Dimmable Ballasts 5, 6, 7 1 ballast 400VA 400VA 400VAPHPM-PA/3FandGRX-TVI6, 7 1 interface 3 interfaces 3 interfaces 3 interfaces
ELVLED See Application Note #559MLVLED6, 7 See Application Note #559
PD-6WCLPD-6WCL-XX-C 8P-PKG1W-WH9, 12
P-BDG-PKG2W9, 13
P-BDG-PKG2W9, 14
P-BDGPRO-PKG1W9, 15
Wireless In-Wall Dimmer
120V~
Incandescent / Halogen 25 W 600 W 500 W 400 W
CFL/LED (120V~ Rated)3 1 bulb3 150 W 150 W 150 W
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987e 6 02.18.19
Ganging and DeratingWhengangingwithotherswitches/dimmersinthesamewallbox,deratingisrequired.See“LoadTypeandCapacity”charts.
Eachswitch/dimmerhas inside fins removed
Middleofgangedswitches/dimmers have all fins removed
Do not remove outside fins on ends of ganged switches/dimmers
Do not remove outside fins on ends of ganged switches/dimmers
Eachswitch/dimmerhas inside fins removed
Middleofgangedswitches/dimmers have all fins removed
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987e 7 02.18.19
Operation
FASS — Front Accessible Service SwitchImportant Notice: To service load, remove power by pulling out the FASS as far as possible. To restore power after servicing load, push the FASS back in completely.
FASS
TM • FAS
STM • FASSTM • FASSTM
• F
AS
STM
• F
ASSTM •
Status LEDIndicates load status; glows softly as night light when load is off
ELV+Dimmer and In-Wall Dimmers
FASS
TM • FAS
STM • FASSTM • FASSTM
• F
AS
STM
• FA
SSTM •
FASSFront Accessible Service Switch
FASSFront Accessible Service Switch
FASSFront Accessible Service Switch
On
Status LEDsIndicates load status; glows softly as night light when load is off
Off
Brighter
Darker
In-Wall Switches
Favorite (Userdefineslightlevel. OnlyavailableinPD-5NE)
On
Off
Plug-In Dimmer Fan Control
Status LEDIndicates load status; glows softly as night light when load is off
On
Off
Brighter
Darker
FASS
TM • FASS
TM • FASSTM • FASSTM
• F
ASS
TM • FA
SSTM •
High
Status LEDsIndicates load status; glows softly as a night light when the fan is off
Off
Faster
Slower
Favorite (Userdefinesfanspeed)
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987e 8 02.18.19
Mounting
Wallplate Adapter / Wallplate purchased separately (Claro Wallplate [CW-1] shown)
Wallplate Adapter Wallplate
Wallbox
Switch/Dimmer
AdapterMountingScrews
Switch/DimmerMountingScrews
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987e 9 02.18.19
DimensionsIn-Wall Switches and Dimmers Fan ControlFront View Side View
5/16 in(8 mm)
5/16 in(8 mm)
11⁄8 in(30 mm)
19⁄16 in(39 mm)
411⁄16 in(119 mm)
215⁄16 in(75 mm)
215⁄16 in(75 mm)
13⁄16 in(30 mm)
23⁄16 in(56 mm)
Front View Side View
31⁄8 in(79 mm)
Plug-In Dimmer
Front View Side View
411⁄16 in(119 mm)
2 9⁄16 in(65 mm)
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987e 10 02.18.19
Wiring Diagrams - Switches
1 When using controls without a mechanical 3-way switch, cap the blue terminal. Do not connect the blue wire to any other wiring or to ground.2 ALUT-MLCensuresproperfunctionwhenLED,fluorescent,orELVloadsareused.InstalltheLUT-MLCinsidealoadfixtureorinaseparatejunctionbox
within the circuit. 3 The red wire must be connected to the load and the black wire must be connected to Line/Hot. The switch will not work if the wires are reversed.
Single Location Installation
PD-5WS-DV
PD-5ANS, PD-6ANS
PD-5WS-DV
PD-5ANS or PD-6ANS
LUT-MLC2Load
Load
Line/Hot
Line/Hot
Neutral
Neutral
Green
Green
Ground
Ground
Black
Black
Black
Red 3
Blue 1
Blue 1
120/277V~ 50/60 Hz
120V~ 50/60 Hz
(continuedonnextpage…)
White
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987e 11 02.18.19
Wiring Diagrams - Switches (cont.)3-Way Installation (with mechanical switch)
Option 1
PD-5WS-DV1Mechanical
Switch 1
BrassBrass
LUT-MLC2Load
Line/Hot
Location 1
Location 2
Neutral
Green
Ground
Ground
Black Black
Blue
120/277V~ 50/60 Hz
Black
Jumper wire
PD-5WS-DV (Load-side)
1 Location of Caséta Wireless in-wall switch and mechanical switch may be reversed.2 ALUT-MLCensuresproperfunctionwhenLED,fluorescent,orELVloadsareused.InstalltheLUT-MLCinsidealoadfixtureorinaseparatejunctionboxwithinthecircuit.
Line/Hot
Neutral
120/277V~ 50/60 Hz
MechanicalSwitch 1
PD-5WS-DV1Black
Location 1 Location 2
Ground
Green
Black
Blue
Brass
Black
Brass
Jumper wireGround
LUT-MLC2Load
PD-5WS-DV (Line-side)
(continuedonnextpage…)
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987e 12 02.18.19
Wiring Diagrams - Switches (cont.)3-Way Installation (with mechanical switch)
Option 1 (cont.)
Location 2
Location 2
PD-5ANS or PD-6ANS 1
MechanicalSwitch 1
BrassBrass
Load
Line/Hot
Neutral
GreenWhiteGround
Ground
Black Red 2
Blue
120V~ 50/60 Hz
Black Jumper wire
PD-5ANS, PD-6ANS (Load-side)
Ground
GreenWhite
Line/Hot
Neutral
120V~ 50/60 Hz
Black Red 2
Blue Brass
Jumper wire
Black
Brass
Load
PD-5ANS or PD-6ANS 1
PD-5ANS, PD-6ANS (Line-side)
MechanicalSwitch 1
Ground
Location 1
Location 1
1 Location of Caséta Wireless in-wall switch and mechanical switch may be reversed.2 The red wire must be connected to the load and the black wire must be connected to Line/Hot. The switch will not work if the wires are reversed.
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987e 13 02.18.19
Wiring Diagrams - Switches (cont.)
1 When using controls without mechanical 3-way switch, cap the blue terminal. Do not connect the blue wire to any other wiring or to ground.2 ALUT-MLCensuresproperfunctionwhenLED,fluorescent,orELVloadsareused.InstalltheLUT-MLCinsidealoadfixtureorinaseparatejunctionbox
within the circuit. 3 The mechanical switch will need to be removed so the Pico remote control can be installed.4 The red wire must be connected to the load and the black wire must be connected to Line/Hot. The switch will not work if the wires are reversed.
3-Way Installation (with Pico remote controls)
Option2:PJ2-2B-xxandwallboxmountingadapters(PICO-WBX-ADAPT)
(continuedonnextpage…)
BlackBlack
PD-5WS-DV
Pico Remote
Control and WallboxMountingAdapter 3
LUT-MLC2Load
Line/Hot
Neutral
Green
Ground
Black
Blue1
120/277V~ 50/60 Hz
Travelers
PD-5WS-DVLocation 1 Location 2
BlackBlack
PD-5ANS or PD-6ANS
Pico Remote
Control and WallboxMountingAdapter 3
Load
Line/Hot
Neutral
GreenWhite
Ground
Red4
Blue1
120V~ 50/60 Hz
Travelers
PD-5ANS, PD-6ANS
Location 1 Location 2
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987e 14 02.18.19
Wiring Diagrams - Switches (cont.)
1 When using controls without mechanical 3-way switch, cap the blue terminal. Do not connect the blue wire to any other wiring or to ground.2 ALUT-MLCensuresproperfunctionwhenLED,fluorescent,orELVloadsareused.InstalltheLUT-MLCinsidealoadfixtureorinaseparatejunctionbox
within the circuit. 3 The mechanical switch will need to be removed so the Pico remote control can be installed.4 The red wire must be connected to the load and the black wire must be connected to Line/Hot. The switch will not work if the wires are reversed.
Multi-location Installation (3 or more switches control the load)WithPicoremotecontrols(PJ2-2B-xx)andwallboxmountingadapters(PICO-WBX-ADAPT)
Pico Remote
Control and WallboxMountingAdapter 3
Pico Remote
Control and WallboxMountingAdapter 3
Pico Remote
Control and WallboxMountingAdapter 3
Pico Remote
Control and WallboxMountingAdapter 3
PD-5ANS or PD-6ANS
PD-5WS-DV
LUT-MLC2
Load
Load
Line/Hot
Line/Hot
Neutral
Neutral
GreenWhite
Green
Ground
Ground
Red 4
Black
Black
Black
Black
Black
Blue1
Blue1
120V~ 50/60 Hz
120/277V~ 50/60 Hz
Travelers
Travelers
Travelers
Travelers
PD-5WS-DV
PD-5ANS, PD-6ANS
Location 1 Location 2 Location 3
Location 1 Location 2 Location 3
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987e 15 02.18.19
Wiring Diagrams - DimmersSingle Location Installation
Line / Hot
120V~ 50 / 60 Hz
Neutral
Black Red
Green
Ground
Load
Blue1, 5
White3,4
PD-10NXD or PD-5NE
PD-6WCL
1 When using controls without mechanical 3-way switch, cap the blue terminal. Do not connect the blue wire to any other wiring or to ground.2 Location of Caséta Wireless in-wall dimmer PRO and mechanical switch may be reversed.3 ForPD-10NXDonly,neutralconnectionoptionalexceptforMLVloads,LEDdrivers,andpowermodules(PHPM-PA,PHPM-3F,andGRX-TVI).4 ForPD-5NE,neutralisrequired.5 Blue wire is only present on the PD-10NXD model.
Line / Hot
120V~ 50 / 60 Hz
Neutral
Black Black
Green
Ground
Load
In-Wall Dimmer
In-Wall Dimmer
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987e 16 02.18.19
Multi-Location InstallationWithPicoremotecontrols(PJ2-XX-XX)andwallboxmountingadapters(PICO-WBX-ADAPT)PD-10NXD and PD-5NE
120V~ 50 / 60 Hz
Neutral
Red
Green
Ground
Load
Line / Hot
Black
Pico remote
control & wallbox
mounting adapter
Pico remote
control & wallbox
mounting adapter
In-Wall Dimmer
Black
Travelers
White3,4
Blue1, 5Travelers
120V~ 50 / 60 Hz
Neutral
Black
Green
Ground
Load
Line / Hot
Black
Pico remote
control & wallbox
mounting adapter
Pico remote
control & wallbox
mounting adapter
In-Wall Dimmer
Black
PD-6WCL
TravelersTravelers
Location 1 Location 2 Location 3
Wiring Diagrams - Dimmers (cont.)
1 When using controls without mechanical 3-way switch, cap the blue terminal. Do not connect the blue wire to any other wiring or to ground.2 Location of Caséta Wireless in-wall dimmer PRO and mechanical switch may be reversed.3 ForPD-10NXDonly,neutralconnectionoptionalexceptforMLVloads,LEDdrivers,andpowermodules(PHPM-PA,PHPM-3F,andGRX-TVI).4 ForPD-5NE,neutralisrequired.5 Blue wire is only present on the PD-10NXD model.
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987e 17 02.18.19
Wiring Diagrams - Dimmers (cont.)3-Way InstallationWith mechanical switch
In-Wall Dimmer2
MechanicalSwitch2
Brass
Brass
Load
Line/Hot
Neutral
GreenGround
Ground
Black
Red
Blue
120V~ 50/60 Hz
Black Jumper wire (included) White3
PD-10NXD
1 When using controls without mechanical 3-way switch, cap the blue terminal. Do not connect the blue wire to any other wiring or to ground.2 Location of in-wall dimmer and mechanical switch may be reversed.3 NeutralconnectionoptionalexceptforMLVloads,LEDdrivers,andpowermodules(PHPM-PA,PHPM-3F,andGRX-TVI).4 See Lutron P/Ns 369356 and 369355 for additional wiring diagrams.5 Blue wire is only present on the PD-10NXD model.
Installation with PHPM - Neutral required4
L/H
N
DH
In-Wall Dimmer
Neutral
Line/Hot
120V~ 60 Hz
Black Ground
GroundWhite
Green
Blue1, 5
RedPHPM
Load
Control NeutralZone In
PD-10NXD and PD-5NE
Location 1Location 2
Location 1
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987e 18 02.18.19
Wiring Diagrams - Dimmers (cont.)Installation with GRX-TVI - Neutral required1
Installation with Hi-lume 1% 2-wire LED Drivers - Neutral required
L2/H
2 100
-277
V~
In-Wall Dimmer
Line/Hot
120V~ 60 Hz
Neutral
Neutral 2
Black
White
Blue 2
Ground
Green
Red
Ground
GRX-TVI
PD-10NXD and PD-5NE
PD-10NXD and PD-5NE
1 See Lutron P/N 369247 for additional wiring diagrams.2 Blue wire is only present on the PD-10NXD model.
In-Wall DimmerLine/Hot
Neutral
Black
WhiteWhite
Black
Black with White StripesGreen
Red
Red
Ground
Hi-lumeR1%2-wireLED
Driver
LEDLightEngine
Note:FormoreinformationonHi-lume1%2-wireLEDdrivers,seewww.lutron.com
Location 1
Blue 2
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987e 19 02.18.19
Wiring Diagrams - Fan ControlsSingle Location Installation
PD-FSQN
PD-FSQN
Ceiling Fan
Line/Hot
Neutral
Green
Ground
Black Yellow
120V~ 50/60 Hz White
3-Way Installation (with Pico remote controls)
PJ2-3BRL-xxx-F01andwallboxmountingadapters(PICO-WBX-ADAPT)
BlackBlack
PD-FSQN
Pico Remote
Control and WallboxMountingAdapter 1
Ceiling Fan
Line/Hot
Neutral
GreenWhite
Ground
Yellow
120V~ 50/60 Hz
Travelers
PD-FSQNLocation 1 Location 2
1 The mechanical switch will need to be removed so the Pico remote control can be installed.
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987e 20 02.18.19
Colors and FinishesGloss Finishes
Due to printing limitations, colors and finishes shown cannot be guaranteed to perfectly match actual product colors.
WhiteWH
BlackBL
IvoryIV
Light AlmondLA
)Lutron, Lutron, Caséta, Pico, Clear Connect, Claro, Hi-lume, FASS, Radio Powr Savr, and Tu-Wire are trademarks or registered trademarks of Lutron ElectronicsCo.,Inc.intheUSand/orothercountries.
PowerSense is a registered trademark of Osram Sylvania. iOSisaregisteredtrademarkofCiscointheU.S.andothercountriesandisusedunderlicense. AndroidisatrademarkofGoogleInc.