Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Catalog HY13-2600-700/US
23
Variable Displacement Piston PumpsSeries P2
SAE B 2-BOLT MTG FLANGE - DIAGONAL MOUNT
SAE C 4-BOLT MOUNTING FLANGE
ISO 6149 STRAIGHTTHD O-RING PORT
M12 X 1.5 THD
ISO 6149 STRAIGHTTHD. O-RING PORT
M22 X 1.5 THD.
"B"SIDE - METRIC
PORT OPTION DRAIN PORTINLET GAUGE PORTOUTLET GAGE PORT
SIGNAL PORT
"A"SIDE - UNC
SAE-10 STRAIGHT THD.O-RING PORT7/8-14 UN THD
SAE-4 STRAIGHT THD.O-RING PORT
7/16-20 UN THD
114.5(4.51)
114.5(4.51)
PORT
GAUGEPORT
GAUGEOUTLET
INLET
12.5(.492)
127.00/126.95(5.000/4.998) 50
(1.97)
235(9.25)
223(8.78)
15(.59)
DRAIN PORTSENSITIVITY4.1 CC/TURN
30 CC MIN
MAX VOL ADJ
9.5(.37)
101.6/101.55(4.000/3.998)
81(3.19)
70(2.76)
15(.59)
50°2 PLACES
146.1(5.75)
B.C.
o/
Dimensional Data
Pump Installation - P2-060 Mounting Flange (side port)
CCW Pump willhave inlet andoutlet gauge portsreversed.
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Variable Displacement Piston PumpsCatalog HY13-2600-700/US
24
Series P2Dimensional Data
Pump Installation - P2-060 Side Port
BOTTOM VIEW
THREAD SIZE SEE CHART
RIPPLE CHAMBER PLUGDO NOT REMOVE
DIFF PRESS ADJ10.7BAR (155PSI)PER TURNSENSITIVITY
OPTIONALDRAINPORTSEE CHART
LIFTING HOOK(3/8-16 THREAD)
SIGNAL PORT SEE CHART
"WEEP HOLE"WET FLANGEBOTH SIDESSEAL OPTIOND & T
126(4.96)
OUTLET PORT1" 4 BOLT FLANGEHIGH PRESSURESERIES (CODE 62)
SIDE VIEW
INLET PORT2" 4 BOLT FLANGESTANDARD PRESSURESERIES (CODE 61)
THREAD SIZE SEE CHART
ROTATIONARROW
TOP VIEW
REAR VIEW
235(9.25)
PRESS COMP ADJ52BAR (758PSI)PER TURNSENSITIVITY
RIPPLECHAMBERPLUGDO NOTREMOVE
85(3.45)
73(2.87)
163(6.41)
114(4.49)
184(7.24)
90(3.54)
109(4.29)
71(2.80)
81(3.19)
81(3.19)
78(3.07)
252(9.92)
66(2.59)
29(1.14)
264(10.39)
224(8.82)
114(4.49)
141(5.55)
144(5.67)
124(4.88)
96(3.78)
76(3.00)
52(2.05)
51(2.00)
76(3.30)
73(2.87)
49(1.93)
45(1.77)
66(2.60)
92(3.62)
73(2.87)
73(2.87)
CLOCKWISE ROTATION SHOWN
PORTINLET &
DRAIN PORT
INLET GAUGE PORT
OUTLET GAUGE PORT
SIGNAL PORT
"A"
UNC1/2-13 UNC
SAE-12 STRAIGHT THD.
O-RING PORT
7/8-14 UN
SAE-4 STRAIGHT THD.
O-RING PORT
7/16-20 UN THD
"B"
METRICM12 X 1.75
ISO 6149 STRAIGHT
THD. O-RING PORT
M22 X 1.5
ISO 6149 STRAIGHT
THD. O-RING PORT
M12 X 1.5 THD.
OUTLETTHREADSOPTION
NOTES:1. Pump shown is a clockwise rotationP2-060 series axial piston pump withload sense and maximum pressurecontrol.
2. Rotation arrow in rear coverindicates proper shaft rotation.
3. Weight of pump shown: 36.5 kg.
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Catalog HY13-2600-700/US
25
Variable Displacement Piston PumpsSeries P2Dimensional Data
Pump Installation - P2-060 Mounting Flange (rear port)
PORTGAUGE
ARROWROTATION
INLET
PAGE 9SEE TABLE
SAE B 2-BOLT MTG FLANGE - DIAGONAL MOUNT
SAE C 4-BOLT MOUNTING FLANGE
SENSITIVITY30 CC MIN
4.1 CC/TURNMAX VOL ADJ
DRAIN PORT
7/16-20 UN THDO-RING PORT
SAE-4 STRAIGHT THD.
7/8-14 UN THDO-RING PORT
SAE-10 STRAIGHT THD.
SIDE - UNC"G"
INLET GAUGE PORTDRAIN PORTPORT OPTION
SIDE - METRIC"H" ISO 6149 STRAIGHT
THD. O-RING PORTM22 X 1.5 THD.
ISO 6149 STRAIGHTTHD O-RING PORT
M12 X 1.5 THD
OUTLET GAUGE PORTSIGNAL PORT
211(8.31)
15(.59)
81(3.19)
101.6(4.0)
9.5(.37)
114.5(4.51)
114.5(4.51)
50°2 PLACES
15(.59)
70(2.76)
127(5.0)
12.5(.492)
146.1(5.75)B.C.
CCW Pump willhave inlet andoutlet gauge portsreversed.
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Variable Displacement Piston PumpsCatalog HY13-2600-700/US
26
Series P2Dimensional Data
Pump Installation - P2-060 Rear Port
THREAD SIZESEE TABLE
INLET PORT2" 4 BOLT FLGSTD PRESS SERIES(CODE 61)
OUTLET PORT1" 4 BOLT FLGHIGH PRESS SERIES(CODE 62)
"WEEP HOLE"BOTH SIDESSEAL OPTIOND & V
OPTIONALDRAINPORT
BOTTOM VIEW
THREAD SIZESEE TABLE
SIDE VIEW
REAR VIEW
(3/8-16 UN-2B THD)LIFTING HOOK
SIGNAL PORT
OUTLETGAUGEPORT
TOP VIEWCLOCKWISE ROTATION SHOWN
PORTINLET &
DRAIN PORT
INLET GAUGE PORT
OUTLET GAUGE PORT
SIGNAL PORT
"G"
UNC1/2-13 UNC
SAE-12 STRAIGHT THD.
O-RING PORT
7/8-14 UN
SAE-4 STRAIGHT THD.
O-RING PORT
7/16-20 UN THD
"H"
METRICM12 X 1.75
ISO 6149 STRAIGHT
THD. O-RING PORT
M22 x 1.5
ISO 6149 STRAIGHT
THD. O-RING PORT
M12 X 1.5 THD.
OUTLETTHREADSOPTION
50(1.97)
104(4.09)
144(5.67)
124(4.88)
96(3.78)
76(3.00)
92(3.62)
45(1.77)
66(2.60)
49(1.93)
141(5.55)
79.3(3.12)
79.3(3.12)
39(1.53)
121(4.76)
71(2.80)
109(4.29)
163(6.41)
90(3.54)
211(2.31)
252(9.92)
104(4.09)
78(3.07)
29(1.14)
114(4.89)
241(9.49)
184(7.24)
66(2.60)
101(3.98)
NOTES:1. Pump shown is a clockwise rotationP2-060 series axial piston pump withload sense and maximum pressurecontrol.
2. Counterclockwise rotation pump willhave inlet and outlet ports reversed.
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Catalog HY13-2600-700/US
27
Variable Displacement Piston PumpsSeries P2Dimensional Data
Pump Installation - P2-060 Shaft Options and Torque Control
"C1" SHAFT OPTIONSAE "C" SPLINE14 TOOTH12/24 PITCH30° INVOLUTE SPLINEMAX INPUT TORQUE:641NM (5677 IN/LBS)
55.6(2.19)
"B2" SHAFT OPTIONSAE "B-B" SPLINE15 TOOTH16/32 PITCH30° INVOLUTE SPLINEMAX INPUT TORQUE:337NM (2987 IN/LBS)
46(1.81)
"B1" SHAFT OPTIONSAE "B" SPLINE13 TOOTH16/32 PITCH30° INVOLUTE SPLINEMAX INPUT TORQUE:209NM (1852 IN/LBS)
41.2(1.62)
"C5" SHAFT OPTIONSAE "C" KEYEDMAX INPUT TORQUE641 NM (5677 IN/LBS)
55.6(2.19)
35.2(1.38)
31.75(1.25)
7.94 (.3125)SQUARE KEY
TORQUE CONTROLOPTIONS "TA","TB","TC & "TD"200 NM (1770 IN LBS) PER TURNAPPROXIMATE SENSITIVITY
33.7(1.33)
161(6.34)
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Variable Displacement Piston PumpsCatalog HY13-2600-700/US
28
Series P2Dimensional Data
Pump Installation - P2-060 Thru-Shaft Option
THRU-SHAFTOPTION A B C D E
FUNC
FMETRIC
GUNC
GMETRIC
PUMPWEIGHT
A1 264(10.4)
82.626/82.575(3.252/3.250)
106.38(4.19)
N/A
SAE-A SPLINE9 TOOTH
16/32 PITCH3/8-16 UNC-2B THD M10 X 1.5 THD
N/A N/A
80 lbs
B1 297(11.7)
101.676/101.625(4.002/4.000)
146.05(5.75)
SAE-B SPLINE13 TOOTH
16/32 PITCH1/2-13 UNC-2B THD M12 X 1.75 THD 86 lbs
B2 297(11.7)
146.05(5.75)
SAE-BB SPLINE15 TOOTH
16/32 PITCH1/2-13 UNC-2B THD M12 X 1.75 THD 86 lbs
C1 C3 299(11.8)
127.076/127.025(5.002/5.000)
180.98(7.125)
SAE-C SPLINE14 TOOTH
12/24 PITCH5/8-11 UNC-2B THD M16 X 2 THD 1/2-13 UNC-2B THD M12 X 1.75 THD 89 lbs
A1 CONFIGURATION B1 & B2 CONFIGURATION
C1 & C3 CONFIGURATION
E
F
E
F
E
F
G
E
B
B
B
CD
D
C
A
264(10.39)
MAX THRU-DRIVE TORQUE IS 336NM (2980 IN/LBS)
C3 ONLY
101.676/101.625(4.002/4.000)
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Catalog HY13-2600-700/US
29
Variable Displacement Piston PumpsSeries P2
SAE C 2 BOLTMOUNTING HOLES2 PLACES.692" DIAMETER
SAE C 4 BOLTMOUNTING HOLES.565" DIAMETER
DRAIN PORT
INLET GAUGEPORT
MAX VOL ADJ4.9 CC/TURNSENSITIVITY52 CC MIN
FLANGE MOUNTING DIMENSIONS - REAR PORTED PUMP
SAE C 2 BOLTMOUNTING HOLES2 PLACES.692" DIAMETER
SAE C 4 BOLTMOUNTING HOLES.565" DIAMETER
DRAIN PORT
MAX VOL ADJ4.9 CC/TURNSENSITIVITY
INLETGAUGEPORT
OUTLETGAUGEPORT
SIDE PORTED PUMPFLANGE MOUNTING DIMENSIONS
PORT OPTION DRAIN PORT INLET GAUGE PORTOUTLET GAUGE PORT
"A"SIDE - UNC
SAE-12 STRAIGHT THD.O-RING PORT
1-1/16-12 UN THD.
SAE-4 STRAIGHT THD.O-RING PORT
7/16-20 UN THD.
"B"SIDE - METRIC
ISO 6149 STRAIGHTTHD. O-RING PORT
M27 X 2 THD.
ISO 6149 STRAIGHTTHD. O-RING PORT
M12 X 1.5 THD.
248.5(9.78)
146(5.75)
123(4.84)
88.2(3.47)
60.5(2.38)
270.5(10.65)
194(7.64)
278.5(10.96)
76(3.00)
81(3.19)
127.00 (5.00)126.95 (4.99)
146(5.75)
62(2.44)
62(2.44)
258.5(10.17)
264.5(10.41)
194(7.63)
278.5(10.96)
76(3.00)
32.4(1.28)
127.00 (5.00)126.95 (4.99)
30o
(4.51)114.5
114.5(4.51)
Dimensional Data
Pump Installation - P2-075 Mounting Flange
CCW Pump willhave inlet andoutlet gauge portsreversed.
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Variable Displacement Piston PumpsCatalog HY13-2600-700/US
30
Series P2Dimensional Data
Pump Installation - P2-075 Side Port
112(4.41)
DIMENSIONS WILL BE REVERSEDON A CCW PUMP
ROTATION ARROW
DIFF PRESS ADJ131PSI (9.1BAR)PER TURNSENSITIVITY
PRESS COMP ADJ921PSI (63.5BAR)PER TURNSENSITIVITY
ALTERNATEDRAIN PORT
SIDE VIEW
OUTLET PORT1" HIGH PRESSSERIES4 BOLT FLG(CODE62)
SIGNAL PORT
INLET PORT2" STD PRESS SERIES4 BOLT FLG (CODE61)
TOP VIEW
BOTTOM VIEW
REAR VIEW
"A"7/16-14 UNC
M12X1.75"B"
"B"M12X1.75
"A"1/2-13 UNC
81(3.19)
81(3.19)
292.5(11.52)
55(2.17)
52(2.05)
51(2.00)
51(2.00)
145(5.71)
123(4.84)
254(10.00)
126.5(4.98)
95(3.19)
88.2(3.47)
60.5(2.38)
90.5(3.56)
81(3.19)
77.5(3.05)
99(.390)
130(5.12)
154(6.06)
84.5(3.33)
102.5(4.04)
67.5(2.66)
201(7.91)
265(10.43)
Weep holefor D & T
RIPPLE CHAMBER PLUGDO NOT REMOVE
CCW Pump willhave inlet andoutlet gauge portsreversed.
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Catalog HY13-2600-700/US
31
Variable Displacement Piston PumpsSeries P2
INLETGAUGEPORT
OUTLET PORT1" HIGH PRESS
SERIES4 BOLT FLG(CODE 62)
INLET PORT2" STD PRESS SERIES4 BOLT FLG(CODE 61)
OPTIONALDRAIN PORT
DIFF PRESS ADJ9.1BAR (132PSI)
PER TURNSENSITIVITY 4MM HEX
PRESS COMP ADJ63.5BAR (921PSI)/
TURN SENSITIVITY4MM HEX
SIGNAL PORT
84.5(3.33)
SIDE VIEW
TOP VIEW
BOTTOM VIEW
REAR VIEW
ISO 6149 STRAIGHTTHD. O-RING PORT
M12 X 1.5 THD.M12 X 1.75M12 X 1.75
"H"SIDE METRIC
SAE-4 STRAIGHT THDO-RING PORT
7/16-20 UN THD7/16-14 UNC1/2-13 UNC
"G"SIDE UNC
SIGNAL & GAUGEOUTLETINLETPORT OPTION
270.5(10.65)
248.5(9.78)
81.8(3.22)
51(2.00)
145(5.71)
52(2.04)
39(1.54)
55(2.17)
102.5(4.04)
67.5(2.66)
201(7.91)
84.5(3.33)
112(4.41)
81.8(3.22)
51(2.00)
NOTES1. The pump shown is a clockwise rotation rear-ported P2-075series axial piston pump with load sense and maximum pressurecontrol.
2. Counter clockwise rotation pumps will have inlet and outletports in opposite locations.
Dimensional Data
Pump Installation - P2-075 Rear Port
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Variable Displacement Piston PumpsCatalog HY13-2600-700/US
32
Series P2Dimensional Data
Pump Installation - P2-075 Shaft Options and Torque Control
SHAFT OPTION "C3"SAE "C" SPLINE NO UNDERCUT14 TOOTH 12/24 PITCH30° INVOLUTEMAX INPUT TORQUE:769NM (6812 IN/LBS)
SHAFT OPTION "C1"SAE "C" SPLINE14 TOOTH 12/24 PITCH30° INVOLUTEMAX INPUT TORQUE:641NM (5677 IN/LBS)
SHAFT OPTION "C2"SAE "CC" SPLINE17 TOOTH 12/24 PITCH30° INVOLUTEMAX INPUT TORQUE:1217NM(10777 IN/LBS)
SHAFT OPTION "C5"SAE "C" KEYEDMAX INPUT TORQUE:641NM (5677 IN/LBS)
SHAFT OPTION "C6"SAE "CC" KEYEDMAX INPUT TORQUE:1217NM (10777 IN/LBS)
55.6(2.19)
62.0(2.44)
SIDE VIEW
69(2.72)
55.6(2.19)
31.9(1.25)
35.2(1.385)
7.94 (.3125)SQUARE KEY
38.1(1.50)
42.3(1.66)
62.0(2.44) 9.525 (.375)
SQUARE KEY
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Catalog HY13-2600-700/US
33
Variable Displacement Piston PumpsSeries P2Dimensional Data
Pump Installation - P2-075 Thru-Shaft Option
82.626/82.575 (3.252/3.250)+ 0 to + .002
SAE-A SPLINE9 TOOTH
16/32 PITCH
101.676/101.625 (4.002/4.001)
127.075/127.025 (5.003/5.001) 181 114.5
181 114.5 1/2-13 UNC-2B
F
F
* ALL SHAFT COUPLINGS 30 DEGREE INVOLUTE SPLINE
FLAT ROOT SIDE FIT
Ø
F
E
F
Ø
THRU-SHAFTOPTION A B C D E F
"A" & "G" UNCF
"B" & "H" METRIC
A1 292.5 106.3 3/8-16 UNC-2B M10 X 1.5
B1 325.5 146.1SAE-B SPLINE
13 TOOTH16/32 PITCH
1/2-13 UNC-2B M12 X 1.75
B2 325.5 146.1SAE-BB SPLINE
15 TOOTH16/32 PITCH
1/2-13 UNC-2B M12 X 1.75
C1 327.5SAE-C SPLINE
14 TOOTH12/24 PITCH
5/8-11 UNC-2B M16 X 2
C3 327.5SAE-C SPLINE
14 TOOTH12/24 PITCH
M12 X 1.75
F
A1 CONFIGURATION
B1 & B2 CONFIGURATION
C1 & C3 CONFIGURATION
Ø
Ø
127.075/127.025 (5.003/5.001)+ .001 to +.003
106.38(4.19)
C
C D
D REF
Ø
101.676/101.625 (4.002/4.001)+ .001 to +.002
88(3.46)
MAX THRU-DRIVE TORQUE IS 336 NM (2973 INLBS)
Pumps will be assembled with flange adapters as shown.Options B1, B2, C1 and C3 can be rotated 90°.
B
B
B
A
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Variable Displacement Piston PumpsCatalog HY13-2600-700/US
34
Series P2Dimensional Data
Pump Installation - P2-105 Mounting Flange
PORT OPTION DRAIN PORTINLET GAUGE PORT
OUTLET GAUGE PORTSIGNAL PORT
"A"SIDE - UNC
SAE-12 STRAIGHT THD.O-RING PORT
1-1/16-12 UN-2B
SAE-4 STRAIGHT THD.O-RING PORT
7/16-20 UN THD
"B"SIDE - METRIC
ISO 6149 STRAIGHTTHD. O-RING PORT
M27 X 2 THD
ISO 6149 STRAIGHTTHD. O-RING PORT
M12 X 1.5 THD.
SHAFT OPTION "C1"SAE "C" SPLINE14 TOOTH 12/24 PITCH30° INVOLUTEMAX INPUT TORQUE:641NM (5677 IN/LBS)
SHAFT OPTION "D1"SAE "D" SPLINE13 TOOTH 8/16 PITCH30° INVOLUTEMAX INPUT TORQUE:1701NM (15057 IN/LBS)
SHAFT OPTION "C5"SAE "C" KEYEDMAX INPUT TORQUE:641NM (5677 IN/LBS)
SHAFT OPTION "C6"SAE "CC" KEYEDMAX INPUT TORQUE:1701NM (15057 IN/LBS)
55.6(2.19)
75.7(2.98)
62(2.44) 9.525(.375)
SQUARE KEY
38.1(1.5)
30°
SAE C 2-BOLTMOUNTING HOLES2 PLACES
SAE C 4-BOLTMOUNTING FLG
114.5(4.51)
194(7.64)
114.5(4.5)
146(5.75)
55.6(2.19) 7.945(.3125)
SQUARE KEY
31.75(1.25)
DRAIN PORT
MAX VOL ADJ5.65CC/TURN SENSITIVITYMIN DISP 70CC/REV
OUTLET GAUGEPORT
INLET GAUGEPORT
103(4.06) 97
(3.82)
102(4.02)
277(10.91)
95(3.74)
CCW Pump willhave inlet andoutlet gauge portsreversed.
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Catalog HY13-2600-700/US
35
Variable Displacement Piston PumpsSeries P2Dimensional Data
Pump Installation - P2-105 Side Port
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Variable Displacement Piston PumpsCatalog HY13-2600-700/US
36
Series P2Dimensional Data
Pump Installation - P2-105 Torque Control
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Catalog HY13-2600-700/US
37
Variable Displacement Piston PumpsSeries P2Dimensional Data
Pump Installation - P2-105 Thru-Shaft Option
*** MAXIMUM THRU DRIVE TORQUE CAPABILITY ISLIMITED TO 587NM (5195 IN/LBS)
323(12.72)
AA1 CONFIGURATION
E
F
B
C
E
E
B1 & B2 CONFIGURATION
B
C
E
G
F
C1 & C3 CONFIGURATION
B
D
D
C
82.626/82.575 (3.252/3.250)
SAE-A SPLINE9 TOOTH
16/32 PITCH
101.676/101.625 (4.002/4.001)
127.075/127.025 (5.003/5.001) 181 114.5
181 114.5 1/2-13 UNC-2B
* ALL SHAFT COUPLINGS 30 DEGREE INVOLUTE SPLINE FLAT ROOT SIDE FIT
Ø
Ø
OPTION A B C D E FUNC
FMETRIC
A1 323•(12.72) 106.3 1/2-13 UNC-2B M10 X 1.5
B1 356•(14.02) 146.1
SAE-B SPLINE13 TOOTH
16/32 PITCH1/2-13 UNC-2B M12 X 1.75 N/A N/A
B2 356•(14.02) 146.1
SAE-BB SPLINE15 TOOTH
16/32 PITCH1/2-13 UNC-2B M12 X 1.75
C1 358•(14.09)
SAE-C SPLINE14 TOOTH
12/24 PITCH1/2-13 UNC-2B M12 X 1.75
C3 358•(14.09)
SAE-C SPLINE14 TOOTH
12/24 PITCHM12 X 1.75 5/8-11 UNC-2B
GUNC
GMETRIC
5/8-11 UNC-2B M16 X 2
M16 X 2
Ø
Ø
127.075/127.025 (5.003/5.001)
Ø
101.676/101.625 (4.002/4.001)
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Variable Displacement Piston PumpsCatalog HY13-2600-700/US
38
Series P2Dimensional Data
Pump Installation - P2-145 Mounting Flange
OUTLET GAUGE
INLET GAUGE
DRAIN PORT
MAX VOLUME ADJ7.8 CC/TURNSENSITIVIY100 CC MINIMUM
SAE C 2 BOLT MOUNTING FLANGE
SAE D 4 BOLT MOUNTING FLANGE
SAE-4 STRAIGHT THD.O-RING PORT
7/16-20 UN THD
SAE-12 STRAIGHT THD.O-RING PORT
1-1/16-12 UN THD
"A"SIDE - UNC
INLET GAUGE PORTOUTLET GAUGE PORT
SIGNAL PORT
DRAIN PORTPORT OPTION
"B"SIDE - METRIC
ISO 6149 STRAIGHTTHD. O-RING PORT
M27 X 1.75 THD.
ISO 6149 STRAIGHTTHD O-RING PORT
M12 X 1.5 THD
161.65(6.36)
161.65(6.36)
152.40/152.35(6.000/5.998)
12.7(.50)
20(.79)
289(11.38)
90(3.54)
82(3.23)
299(11.77)
92(3.62)
12.7(.50)
112(4.41)
15(.59)
180.98(7.125)
127.00/126.95(5.000/4.998)
O
O
Note: Counter clockwise rotation pump will have inlet and outlet gauge ports reversed.
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Catalog HY13-2600-700/US
39
Variable Displacement Piston PumpsSeries P2Dimensional Data
Pump Installation - P2-145 Side Port
OPTIONAL DRAIN PORT
ROTATION ARROW
RIPPLE CHAMBERPLUGDO NOT REMOVE
OUTLET PORT1-1/4 INCH HIGH PRESSSERIES 4 BOLT FLANGE(CODE 62)
SIGNAL PORT
LIFTING HOOK3/8-16 UN-2B
PRESSURE COMPADJUSTMENT63.5 BAR(921PSI)/•TURN SENSITIVITY
DIFF PRESSUREADJUSTMENT9.1 BAR(132PSI)/TURN SENSITIVITY
OPTIONAL DIFF PRESSTEST PORT (-4 SAE)
"WEEP HOLE"BOTH SIDESSEAL OPTIOND & T
54(2.13)
INLET PORT2-1/2 INCH STD PRESSSERIES 4 BOLT FLANGE(CODE 61)
THREAD - SEE TABLE
THREAD:SEE
TABLE
TOP VIEW
SIDE VIEW
BOTTOM VIEW
REAR VIEW
PORTOPTION
INLETPORT
OUTLETPORT
DRAIN PORTINLET GAUGE PORT
OUTLET GAUGE PORTSIGNAL PORT
"A"SIDE - UNC 1/2-13 UNC 1/2-13 UNC
SAE-12 STRAIGHT THD.O-RING PORT
1-1/16-12 UN-2B
SAE-4 STRAIGHT THD.O-RING PORT
7/16-20 UN THD
"B"SIDE - METRICM12 X 1.75 M12 X 1.75
ISO 6149 STRAIGHTTHD. O-RING PORT
M27 X 2 THD
ISO 6149 STRAIGHTTHD. O-RING PORT
M12 X 1.5 THD.
130(5.12)
299(11.77)
70(2.76)
220(8.66)
102(4.02)
110(4.33)
64(2.52)
98(3.86)
121(4.76)
302/292.5(11.89/11.52)
142(84.33)
82(3.23)
127(5.00)
207(8.15)
58(2.28)
87(3.43)
114(4.49)
181(7.13)
164(6.46)
57(2.24)
59(2.32)
100(3.94)
100(3.94)
107(4.21)
118(4.65)
109(4.29)
131(5.16)
162(6.38)
186(7.32)
284(11.18)
118(4.65)
107(4.21)
330(13.00)
NOTES:1. PUMP SHOWN IS A CLOCKWISE ROTATION P2-145 SERIES AXIAL PISTON PUMP WITH LOADSENSE AND MAXIMUM PRESSURE CONTROL2. COUNTERCLOCKWISE ROTATION PUMP WILLHAVE RIPPLE CHAMBER REVERSED.3. MASS OF PUMP SHOWN: 81.8 Kg
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Variable Displacement Piston PumpsCatalog HY13-2600-700/US
40
Series P2Dimensional Data
Pump Installation - P2-145 Shaft Options and Torque Control
(15057 in-lbs) 1701 NmMAX INPUT TORQUE:SAE D KEYED"D3" SHAFT OPTION
SHAFT OPTIONDISPLACEMENT WITH THIS235 BAR (3408PSI) MAX AT FULLPUMP MUST BE DE-RATED TO**NOTE
(5677 in-lbs) 641 NmMAX INPUT TORQUE:30 INVOLUTE SPLINE12/24 PITCH14 TOOTHSAE C"C1" SHAFT OPTION
(15057 in-lbs) 1701 NmMAX INPUT TORQUE:30 INVOLUTE SPLINE8/16 PITCH13 TOOTH
SAE D"D1" SHAFT OPTION
(7.95)202
200 NM (1770 IN LBS)/TURNAPPROXIMATE SENSITIVIY:
OPTIONS "TA","TB","TC" & "TD"TORQUE CONTROL
(2.22) 56.5
(2.98) 75.6
(1.94) 49.4
(1.75) 44.4
(2.98) 75.6
SQUARE KEY11.11 (.4375)
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Catalog HY13-2600-700/US
41
Variable Displacement Piston PumpsSeries P2Dimensional Data
Pump Installation - P2-145 Thru-Shaft Option
A
(12.97)329.5
152.475/152.425 (6.003/6.001)
(5.003/5.001) 127.075/127.025
127.075/127.025 (5.003/5.001)
(5.003/5.001) 127.075/127.025
127.075/127.025 (5.003/5.001)
101.676/101.625 (4.002/4.001)
(4.002/4.001) 101.676/101.625
82.626/82.575 (3.252/3.250)
E
LIMITED TO 1217 Nm (10777 in-lbs)MAXIMUM THRU-DRIVE TORQUE CAPABILITY IS***NOTE***
194M16 X 2 THD3/4-10 UNC-2B THDN/AN/A8/16 PITCH13 TOOTHSAE-D SPLINE
161.65N/AØ375D3
185M12 X 1.75 THD1/2-13 UNC-2B THDM16 X 2 THD5/8-11 UNC-2B THD12/24 PITCH17 TOOTHSAE-CC SPLINE
114.50180.98Ø364.5C4
185M12 X 1.75 THD1/2-13 UNC-2B THDM16 X 2 THD5/8-11 UNC-2B THD12/24 PITCH14 TOOTHSAE-C SPLINE
114.50180.98Ø364.5C3
185M12 X 1.75 THD1/2-13 UNC-2B THDM16 X 2 THD5/8-11 UNC-2B THD12/24 PITCH17 TOOTHSAE-CC SPLINE
180.98Ø364.5C2
185M12 X 1.75 THD1/2-13 UNC-2B THDM16 X 2 THD5/8-11 UNC-2B THD12/24 PITCH14 TOOTHSAE-C SPLINE
180.98Ø364.5C1
182M12 X 1.75 THD1/2-13 UNC-2B THD16/32 PITCH15 TOOTHSAE-BB SPLINE
146.05Ø362.5B2
182M12 X 1.75 THD1/2-13 UNC-2B THD16/32 PITCH13 TOOTHSAE-B SPLINE
146.05Ø362.5B1
176
N/AN/A
M10 X 1.5 THD3/8-16 UNC-2B THD16/32 PITCH9 TOOTHSAE-A SPLINE
N/A
106.38Ø329.5A1
WEIGHT (LBS)PUMP
METRICG
UNCG
METRICF
UNCFEDCBAOPTION
THRU-SHAFT
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Variable Displacement Piston PumpsCatalog HY13-2600-700/US
42
Series P2Dimensional Data
D3 CONFIGURATION
E
G
C1, C2, C3 & C4 CONFIGURATION
E
E
E
B1 & B2 CONFIGURATION
A1 CONFIGURATION
B
D
D
C
F
G
D
D
B
C
F
B
FB
C
Pump Installation - P2-145 Thru-Shaft Option
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Catalog HY13-2600-700/US
43
Variable Displacement Piston PumpsSeries P2Operating and Installation
Recommended Operating and Installation Instructions
Speed Minimum 600 RPMMaximum 2800 RPM P2060Maximum 2500 RPM P2075Maximum 2300 RPM P2105Maximum 2200 RPM P2145
Pressure Limited by the pressure compensator control in the pump. Maximum allowable setting 320 Bar (4640 PSI)
Flow P2060 168.0 l/min (44.4 GPM) @ 2800 RPMP2075 187.5 l/min (49.5 GPM) @ 2500 RPMP2105 241.5 l/min (63.8 GPM) @ 2300 RPMP2145 319.0 l/min (84.3 GPM) @ 2200 RPM
Inlet Not to exceed p min 0,8 bar (abs) and p max 10 bar (abs) (vacuum) atConditions maximum rate speed on petroleum based fluids. Inlet pressure not to exceed 10 Bar (145 PSI).
Filtration For maximum pump and system component life, fluid contamination should be limited to 20/18/14 accordingto ISO4406. Due to the nature of variable volume pumps, pump inlet conditions, types of fluids and dutycycles must be considered before specifying suction filtration. Contact Parker Representative for assistance.
Temperature Normal working fluid temperature in tank 0°C - 70°C (+32°F to +158°F)Range Maximum operating case drain temperature 90°C (+194°F)
Cold start temperature -40°C (-40°F)
Fluid Premium hydraulic fluid with a normal operating viscosity range between 15 - 40 cSt. Maximum viscosity is1000 cSt for short periods. Minimum viscosity is 10 cSt for short periods. Oil should have maximum anti-wear properties, rust, and oxidation inhibitors.
Case Drain In full compensation @ 320 Bar (4640 PSI) the normal case drain flow is 8 l/min (2.1 GPM) P206010 l/min (2.6 GPM) P207513 l/min (3.4 GPM) P210515 l/min (4.0 GPM) P2145
Maximum allowable back pressure is .5 Bar (7.75 PSI) continuousMaximum allowable back pressure is 2 Bar (29.0 PSI) intermittent
Parker Hannifin CorporationHydraulic Pump/Motor DivisionGreeneville, Tennessee, USA
Catalog HY13-2600-700/US
45
Variable Displacement Piston PumpsSeries P2Notes