+ All Categories
Home > Documents > Catalog Pages: TESCOM™ 26-1200 SeriesA secondary pressure drop due to the outlet cross-hole can...

Catalog Pages: TESCOM™ 26-1200 SeriesA secondary pressure drop due to the outlet cross-hole can...

Date post: 23-Apr-2020
Category:
Upload: others
View: 11 times
Download: 0 times
Share this document with a friend
8
26-1200 SERIES TESCOM 26-1200 Series dome loaded, high flow pressure reducing regulator is externally loaded with 6000 psig / 414 bar maximum inlet and outlet pressures. The 26-1200 Series offers four C v ratings, balanced main valve, and available external sensing. Applications • Rocket engine testing • Fueling • Facilities supply • Natural gas pipeline Features and Benefits • Diaphragm or piston sensed • Modular construction for easy service • External sensing available for improved accuracy • Balanced main valve increases seat life • Mounts in any position • Low droop and lockup Specifications For other materials or modifications, please consult TESCOM. OPERATING PARAMETERS Pressure rating per criteria of ANSI/ASME B31.3 Maximum Inlet Pressure 3600 and 6000 psig 248 and 414 bar Outlet Pressure To maximum inlet Design Proof Pressure 150% maximum rated operating Leakage Bubble-tight Flow Capacity C v = 3.3, 6.0, 12.0* or 20.0 MEDIA CONTACT MATERIALS Body 303 Stainless Steel, 316 Stainless Steel Seat PCTFE or Polyimide (Vespel ® ) Diaphragm Nitrile, Buna-N or FKM (Viton ® -A) O-Rings Nitrile, Buna-N or FKM (Viton ® -A) Back-up Rings PTFE Remaining Parts 300 Series Stainless Steel OTHER Cleaning CGA 4.1 and ASTM G93 Teflon ® , Tefzel ® , Vespel ® , and Viton ® are registered trademarks of E.I. du Pont de Nemours and Company. *A secondary pressure drop due to the outlet cross-hole can significantly affect the rated flow capacity. Contact TESCOM for flow curve data when outlet pressure is less than 1000 psig / 69.0 bar. C v = 12.0 C v = 3.3 C v = 6.0 PILOT PRESSURE REGULATOR EXTERNAL REFERENCE LINE 26-1200 PROCESS PRESSURE REGULATOR TYPICAL APPLICATION 26-1200 Series Regulators - Pressure Reducing D26120540X012 117 Visit our website at emerson.com or contact us at (800) 447-1250
Transcript
Page 1: Catalog Pages: TESCOM™ 26-1200 SeriesA secondary pressure drop due to the outlet cross-hole can significantly affect the rated flow capacity. Contact TESCOM for flow curve data when

26-1200 SERIES

TESCOM 26-1200 Series dome loaded, high flow pressure reducing regulator is externally loaded with 6000 psig / 414 bar maximum inlet and outlet pressures. The 26-1200 Series offers four Cv ratings, balanced main valve, and available external sensing.

Applications• Rocket engine testing

• Fueling

• Facilities supply

• Natural gas pipeline

Features and Benefits• Diaphragm or piston sensed

• Modular construction for easy service

• External sensing available for improved accuracy

• Balanced main valve increases seat life

• Mounts in any position

• Low droop and lockup

SpecificationsFor other materials or modifications, please consult TESCOM.

OPERATING PARAMETERS Pressure rating per criteria of ANSI/ASME B31.3

Maximum Inlet Pressure3600 and 6000 psig

248 and 414 bar

Outlet PressureTo maximum inlet

Design Proof Pressure150% maximum rated operating

LeakageBubble-tight

Flow CapacityCv = 3.3, 6.0, 12.0* or 20.0

MEDIA CONTACT MATERIALSBody

303 Stainless Steel, 316 Stainless Steel

SeatPCTFE or Polyimide (Vespel®)

DiaphragmNitrile, Buna-N or FKM (Viton®-A)

O-RingsNitrile, Buna-N or FKM (Viton®-A)

Back-up RingsPTFE

Remaining Parts300 Series Stainless Steel

OTHERCleaning

CGA 4.1 and ASTM G93

Teflon®, Tefzel®, Vespel®, and Viton® are registered trademarks of E.I. du Pont de Nemours and Company.

*A secondary pressure drop due to the outlet cross-hole can significantly affect the rated flow capacity. Contact TESCOM for flow curve data when outlet pressure is less than 1000 psig / 69.0 bar.

Cv = 12.0

Cv = 3.3

Cv = 6.0

PILOT PRESSURE REGULATOR

EXTERNAL REFERENCE LINE

26-1200 PROCESS PRESSURE REGULATOR

TYPICAL APPLICATION

26-1200 SeriesRegulators - Pressure Reducing D26120540X012

117Visit our website at emerson.com or contact us at (800) 447-1250

Page 2: Catalog Pages: TESCOM™ 26-1200 SeriesA secondary pressure drop due to the outlet cross-hole can significantly affect the rated flow capacity. Contact TESCOM for flow curve data when

118

26-1200 Series Regulator Specifications

*For extended temperature applications, consult TESCOM.

CV OPERATING PARAMETERS Pressure rating per criteria of ANSI/ASME B31.3

MEDIA CONTACT MATERIALS OTHER

Cv = 3.3 Maximum Inlet PressureStainless Steel Body:

6000 psig / 414 bar

Operating Temperature*-40°F to 165°F / -40°C to 74°C

Flow CapacityCv = 3.3

Body303 Stainless Steel or 316 Stainless

SteelSeat

PCTFE or Vespel®

DiaphragmNitrile, Buna-N

Back-up RingsPTFE

GasketPCTFE

Retaining Ring15-7 Stainless Steel

Valve Cap17-4 Stainless Steel

Remaining Parts300 Series Stainless Steel

WeightStainless Steel: 25 lbs / 11.3 kg

Cv = 6.0 Maximum Inlet PressureVespel: 6000 psig / 414 bar

PCTFE or ETFE (Tefzel®): 3600 psig / 248 bar

Operating Temperature* Nitrile, Buna-N: -40°F to 165°F / -40°C to 74°C FKM (Viton®-A): -15°F to 165°F / -26°C to 74°C

Flow CapacityCv = 6.0

Body316 Stainless Steel

SeatPCTFE or Polyimide (Vespel®)

DiaphragmBuna-N or FKM (Viton®-A)

O-RingsNitrile, Buna-N or FKM (Viton®-A)

Back-up RingsPTFE

Connecting Rod17-4 Stainless Steel

ValveNitronic 60

Remaining Parts300 Series Stainless Steel

WeightStainless Steel: 40 lbs / 18.1 kg

26-1200 SERIES

Visit our website at emerson.com or contact us at (800) 447-1250

Page 3: Catalog Pages: TESCOM™ 26-1200 SeriesA secondary pressure drop due to the outlet cross-hole can significantly affect the rated flow capacity. Contact TESCOM for flow curve data when

119

26-1200 Series Regulator Specifications

*For extended temperature applications, consult TESCOM.

CV OPERATING PARAMETERS Pressure rating per criteria of ANSI/ASME B31.3

MEDIA CONTACT MATERIALS OTHER

Cv = 12.0 Maximum Inlet Pressure6000 psig / 414 bar

Operating Temperature*-15°F to 165°F / -26°C to 74°C

Flow CapacityCv = 12.0

Body316 Stainless Steel

SeatPolyimide (Vespel®)

DiaphragmFKM (Viton®-A)

O-RingsFKM (Viton®-A)

Back-up RingsPTFE

Connecting Rod17-4 Stainless Steel

ValveNitronic 60

Remaining Parts300 Series Stainless Steel

WeightStainless Steel: 60 lbs / 27.2 kg

Cv = 20.0 Maximum Inlet Pressure3600 psig / 248 bar

Operating Temperature*-40°F to 200°F / -40°C to 93°C

Flow CapacityCv = 20.0

Body316 Series Stainless Steel

Seat PCTFE, Peek, Polyimide (Vespel® SP1)

O-RingsNitrile, Buna-N or FKM (Viton®-A)

Back-up RingsPTFE

ValveNitronic 60

Remaining Parts316 Series Stainless Steel

WeightStainless Steel: 130 lbs / 58.9 kg

26-1200 SERIES

Visit our website at emerson.com or contact us at (800) 447-1250

Page 4: Catalog Pages: TESCOM™ 26-1200 SeriesA secondary pressure drop due to the outlet cross-hole can significantly affect the rated flow capacity. Contact TESCOM for flow curve data when

120

26-1200 Series Regulator Drawings

Cv = 3.3 - 1/2" [12.7] ORIFICE

Cv = 6.0 - 5/8" [15.9] ORIFICE

All dimensions are reference & nominal Metric [millimeter] equivalents are in brackets

26-1200 SERIES

Visit our website at emerson.com or contact us at (800) 447-1250

Page 5: Catalog Pages: TESCOM™ 26-1200 SeriesA secondary pressure drop due to the outlet cross-hole can significantly affect the rated flow capacity. Contact TESCOM for flow curve data when

121

26-1200 Series Regulator Drawings

All dimensions are reference & nominal Metric [millimeter] equivalents are in brackets

Cv = 12.0 - 1" [25.4] ORIFICE

All dimensions are reference & nominal Metric [millimeter] equivalents are in brackets

Cv = 20.0 - 1.25" [31.75] ORIFICE

3.073.03

77.976.9

2.50 [63.5]BOTH SIDES

4x 1/2-20 UNF.50 [12.7] DEEP MOUNT HOLES

DOME PORT1/4 MS33649

EXTERNAL REF PORT1/4 MS33649

5.5 [139.7]

4.464.42

113.3112.3

3.053.01

77.676.5

11.7211.62

297.8295.3

IN OUT

6.50 [165.1]

ø 3.04 [77.2]

Ext. sensingport fitting(plugged for internal sense)

26-1200 SERIES

Visit our website at emerson.com or contact us at (800) 447-1250

Page 6: Catalog Pages: TESCOM™ 26-1200 SeriesA secondary pressure drop due to the outlet cross-hole can significantly affect the rated flow capacity. Contact TESCOM for flow curve data when

122

OU

TLE

T P

RE

SS

UR

E -

psig

[ba

r]

FLOW RATE - SCFM [SLPM] Nitrogen

0 5000[141,584]

P1 = 6000 psig [414 bar]

6000

60004500

4500 and 600030001500[103]

4500[310]

3000[207]

10,000[283,168]

15,000[424,752]

1000[69.0]

2000[138]

3000[207]

4000[276]

5000[345]

6000[414]

7000[483]

Model No. 26-126T-3162-076Cv = 6.0

For more information on how to read flow curves, please refer to the Flow Curves and Calculations document (debul2007x012) in the TESCOM catalog or on www.tescom.com.

26-1200 Series Regulator Flow ChartO

UT

LET

PR

ES

SU

RE

- ps

ig [

bar]

FLOW RATE - SCFM [SLPM] Nitrogen

0 900[25,485]

1800[50,970]

P1 = 6000 psig [414 bar]

60004500[310]

45003000[207]

6000

450030001500[103]

6000

2700[76,455]

3600[101,940]

4500[127,425]

5400[152,910]

6300[178,395]

1500[103]

3000[207]

4500[310]

6000[414]

26-1221-3161 Curves Model No. 26-1261-3161Cv = 3.3

26-1200 SERIES

Visit our website at emerson.com or contact us at (800) 447-1250

Page 7: Catalog Pages: TESCOM™ 26-1200 SeriesA secondary pressure drop due to the outlet cross-hole can significantly affect the rated flow capacity. Contact TESCOM for flow curve data when

123

For more information on how to read flow curves, please refer to the Flow Curves and Calculations document (debul2007x012) in the TESCOM catalog or on www.tescom.com.

26-1200 Series Regulator Flow ChartsO

UTL

ET P

RES

SUR

E ps

ig [b

ar]

1200[82.7]

1000[68.9]

800[55.1]

600[41.3]

400[27.5]

200[12.7]

0200,000[5663]

400,000[11,326]

600,000[16,990]

800,000[22,653]

1,000,000[28,316]

12,000,000[33,980]

FLOW RATE– SCFH [Nm3/h]

P1= 1400 psig [96.5 bar]

1400 psig [96.5 bar]

1200 psig [82.7 bar]

1100 psig [75.8 bar]

OU

TLE

T P

RE

SS

UR

E -

psig

[ba

r]

FLOW RATE - SCFM [SLPM] Nitrogen

0 10,000[283,168]

20,000[566,336]

30,000[849,504]

40,000[1,132,672]

P1 = 6000 psig [414 bar]

6000

6000

4500 and 6000

4500[310]

45003000[207]

30001500[103]

1000[69.0]

2000[138]

3000[207]

4000[276]

5000[345]

6000[414]

7000[483]

Model No. 26-126V-CLE5-164

Cv = 20.0

Model No. 26-1261-2163-083Cv = 12.0

The curves above were generated using analytical methods - error is estimated at ±10%

26-1200 SERIES

Visit our website at emerson.com or contact us at (800) 447-1250

Page 8: Catalog Pages: TESCOM™ 26-1200 SeriesA secondary pressure drop due to the outlet cross-hole can significantly affect the rated flow capacity. Contact TESCOM for flow curve data when

124

Cv = 12.0

26-12 6 1 - 2 16 3 - 083

BASICSERIES BODY MATERIAL LOADING METHOD INLET AND OUTLET

PORT TYPEDOME PORT

INLET AND OUTLET PORT SIZE SENSE TYPE MODEL NUMBER

26-12 6 – 316 Stainless Steel 1 – External 1 – SAE 2 – NPTF 3 – MS33649

1/4" MS33649 1/4" NPTF 1/4" MS33649

16 – 1" 20 – 1-1/4"

3 – Internal 4 – External

083

MANDATORY FOR Cv = 12.0 MODEL

26-1200 Series Regulator Part Number SelectorRepair Kits, Accessories & Modifications may be available for this product. Please contact TESCOM for more information.

Example for selecting a part number:

Cv = 3.3

26-12 2 1 - 3 16 1

BASICSERIES BODY MATERIAL LOADING METHOD INLET AND OUTLET

PORT TYPEDOME PORT PORT SIZE ORIFICE SIZE

26-12 2 – 303 Stainless Steel 6 – 316 Stainless Steel

1 – External 1 – SAE2 – NPTF3 – MS33649

1/4" MS33649 1/4" NPTF 1/4" MS33649

12 – 3/4" 16 – 1"

1 – 1/2" 12.7 mm

Cv = 6.0

26-12 6 T - 3 16 2 - 076

BASICSERIES

BODY MATERIAL

DIAPHRAGM/ O-RING SEAT TEMPERATURE INLET AND OUTLET

PORT TYPEDOME PORT

INLET AND OUTLET PORT SIZE

INNER VALVE SIZE

MOD. NUMBER

26-12 6 – 316 Stainless Steel

A – Nitrile, Buna-N B – Nitrile, Buna-N D – Nitrile, Buna-N E – FKM (Viton®-A)

T – FKM (Viton®-A)

V – FKM (Viton®-A)

W – FKM (Viton®-A)

Polyimide (Vespel®

SP1)

Polyimide (Vespel®

SP1)

PCTFE Polyimide (Vespel®

SP1) PCTFE

Polyimide (Vespel®

SP1) ETFE

(Tefzel®)

-40°F to 165°F -40°C to 74°C -40°F to 165°F -40°C to 74°C -40°F to 165°F -40°C to 74°C -15°F to 300°F -26°C to 149°C -15°F to 165°F -26°C to 74°C -15°F to 300°F -26°C to 149°C -15°F to 165°F -26°C to 74°C

1 – SAE 2 – NPTF 3 – MS33649

1/4" MS33649 1/4" NPTF 1/4" MS33649

12 – 3/4" * 16 – 1" 20 – 1-1/4" SAE or

MS only

2 – 5/8" 15.9 mm

076

*3/4" ports reduce overall Cv to 5.0

MANDATORY FOR Cv = 6.0

Cv = 20.0

26-12 6 V-C LA 2 - 164

BASICSERIES

BODY MATERIAL O-RING SEAT TEMPERATURE INLET & OUTLET

PORT TYPEPRESSURE

RANGEINLET & OUTLET MAX PRESSURE

END TO ENDDIMENSIONS

INCH [MM]

SENSE TYPE

MOD. NUMBER

26-12 6 – 316 Stainless Steel

D-C – Nitrile, Buna-N D-P – Nitrile, Buna-N D-V – Nitrile, Buna-N V-C – FKM (Viton®-A)

V-P – FKM (Viton®-A)

V-V – FKM (Viton®-A)

PCTFE PEEK®

Polyimide (Vespel®

SP1)

PCTFE

PEEK®

Polyimide (Vespel®

SP1)

-40°F to 165°F -40°C to 74°C -40°F to 200°F -40°C to 93°C -40°F to 200°F -40°C to 93°C -10°F to 165°F -23°C to 74°C -10°F to 200°F -23°C to 93°C -10°F to 200°F -23 °C to 93°C

LA– 2" Grayloc GR20LB– 2" Grayloc GR14LC– 2" 1500# RTJLD– 2" 2500# RTJLE– 2" 1500# RFLF– 2" 2500# RF

Low Low Low Low Low Low

3600 PSIG [248 bar]3600 PSIG [248 bar] 3100 PSIG [214 bar]3600 PSIG [248 bar]3100 PSIG [214 bar]3600 PSIG [248 bar]

14.75 [374.7]14.75 [374.7]17.88 [454.0]19.88 [504.8]17.75 [450.8]19.75 [501.6]

5 – Internal6 – External

164

MANDATORY FOR Cv = 20.0

Note: Contact Engineering for pressures above 3600 PSI/248 bar

26-1200 SERIES

Visit our website at emerson.com or contact us at (800) 447-1250


Recommended