TURBINES
PK Turbine pumps with peripheral impeller, END SUCTION . . . . . . . . . . . . . . . . . . . . . . . . .2PQ Turbine pumps with peripheral impeller, SIDE SUCTION . . . . . . . . . . . . . . . . . . . . . . . . .4PQA Turbine pumps with peripheral impeller, SIDE SUCTION, PLASTIC – BRASS PUMP BODY . .8
CENTRIFUGAL
CP End suction centrifugal pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10AR End suction STAINLESS STEEL centrifugal pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18PNGA End suction 316 STAINLESS STEEL centrifugal pump . . . . . . . . . . . . . . . . . . . . . . . . . 20
MULTI STAGE
3-4 CP Multi-stage centrifugal pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223-4 CR Multi-stage centrifugal pumps, STAINLESS STEEL PUMP BODY . . . . . . . . . . . . . . . . .24VL Vertical Multi-stage Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26VLE Inline Multi-stage Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
SELF PRIMING
PKS Self priming with peripheral impeller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34JSW Shallow well self priming jet pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36JCR Shallow well self priming jet pumps, STAINLESS STEEL PUMP BODY . . . . . . . . . . . .38JD Self priming pump for deep well . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40PLURIJET Self priming MULTI-STAGE pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
BRONZE
BZ Pump with bronze body . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
INDEX
SUMP
TOP Sump pumps for clear water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52TOP FLOOR Sump pumps for clear water, LOW SUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54TOP VORTEX VORTEX Sump pumps for dirty water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56TOP MULTI MULTI-STAGE sump pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58RX STAINLESS STEEL sump pump for clear water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60RX VORTEX VORTEX stainless steel sump pump, for dirty water . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
EFFLUENT
D Effluent pumps for dirty water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
SEWAGE
VX Vortex sewage pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66VXS Vortex STAINLESS STEEL sewage pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68VXCH-M Vortex CAST IRON sewage pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70VXC-L Vortex CAST IRON sewage pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72MC Double channel sewage pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74MCS Double channel STAINLESS STEEL sewage pumps . . . . . . . . . . . . . . . . . . . . . . . . . . .76MCM Double channel CAST IRON sewage pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78MC-L Double channel CAST IRON sewage pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80
SUBMERSIBLE
4SK Submersible pump with peripheral impeller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82SUMO Multi-stage submersible pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .844BLOCK 4” Monoblock submersible pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
2
Flow rate up to 24 gpmHead up to 328 ft
Manometric suction lift up to 26 ftLiquid temperature up to + 140°FEnvironment temperature up to + 104°F
They are recommended for pumping clean water without abrasiveparticles and liquids that are chemically non aggressive to the materialsfrom which the pump is made.FOR THEIR RELIABILITY, SIMPLICITY OF USE AND ECONOMYTHEY ARE SUITABLE FOR RESIDENTIAL USE AND INPARTICULAR FOR DISTRIBUTING WATER IN COMBINATION WITHSMALL PRESSURE SETS, FOR IRRIGATING GARDENS.The pumps must be installed in enclosed places, or at least protectedagainst inclement weather.
• PUMP BODY: cast iron, with threaded ports.
• MOTOR BRACKET (patent nº 1289150): aluminium with brass insert; reduces starting difficulties due to seizure of the impeller afterlong periods of inactivity.
• IMPELLER: brass, of the type with radial peripheral vanes.
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• MECHANICAL SEAL: ceramic - graphite - NBR.
• ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty.PK: single-phase 115 V or 230 V - 60Hz with capacitor and
thermal overload protector.PK: three-phase 230/460 V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 44.
• REGISTERED MODEL nº 72753.
⇒ special mechanical seal⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
PK pumps with peripheral impeller
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
3
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
PK 20
PK 15PKH 07
PK 10
PK 07
PKH 05
PK 05
PK 03Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
f
a w ms
DN2i
n1
n
DN
1 h3 h
h1
h2
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN1 DN2 a f h h1 h2 h3 i m n n1 w s 1~ 3~PK 03 PK 03 1" 1" 1.7 9.5 5.9 2.4 2.9 5.4 0.7 3.1 4.7 3.9 2.1 0.2 11.7 11.7
PK 05 PK 05 1" 1" 1.9 10,15/9,84 5.9 2.4 3.1 5.6 0.7 3.1 4.7 3.9 2.1 0.2 17.0 14.1
PKH 05 PKH 05 1" 1" 2.2 11.2 7.0 2.8 3.3 6.1 0.7 3.5 5.4 4.4 2.4 0.2 22.3 20.3
PK 07 PK 07 1" 1" 2.2 11.2 7.0 2.8 3.3 6.1 0.7 3.5 5.4 4.4 2.4 0.2 22.7 21.8
PKH 07 PKH 07 3/4" 3/4" 2.3 11.3 7.0 2.8 3.7 6.5 0.7 3.5 5.4 4.4 2.4 0.2 22.7 20.5
PK 10 PK 10 1" 1" 2.2 13.7 8.3 3.1 3.7 6.8 0.7 3.9 6.2 4.9 3.3 0.3 33.1 28.9
PK 15 PK 15 1" 1" 2.2 13.7 8.3 3.1 3.7 6.8 0.7 3.9 6.2 4.9 3.3 0.3 35.3 33.5
PK 20 1" 1" 2.2 13.7 8.3 3.1 3.7 6.8 0.7 3.9 6.2 4.9 3.3 0.3 39.7
MODELHP
FLOW RATE GPM 0 1.2 2.7 4 5.5 6.6 8 9.3 10.2 13.2 15 18 21 23
1 PH 3 PH FLOW RATE l/min 0 5 10 15 20 25 30 35 40 50 60 70 80 90
PK 03 PK 03 0.33
H Feet
131 124 110 95 78 64 49 32 16
PK 05 PK 05 0.5 181 164 149 133 118 101 88 72 55 26
PKH 05 PKH 05 0.5 214 203 187 170 154 137 121 105 88 59
PK 07 PK 07 0.7 230 216 200 183 167 151 134 119 101 72
PKH 07 PKH 07 0.7 296 269 233 197 160 124 88 55 16
PK 10 PK 10 1 279 262 246 229 213 197 180 164 147 114 82 49
PK 15 PK 15 1.5 296 282 266 249 233 215 197 180 164 131 98 65 32
PK 20 2 329 312 295 279 262 246 229 213 197 164 131 98 65 32
4
Flow rate up to 24 gpmHead up to 328 ft
Manometric suction lift up to 26 ftLiquid temperature up to + 194°FEnvironment temperature up to + 104°F
They are recommended for pumping clean water without abrasiveparticles and liquids that are chemically non aggressive to the materialsfrom which the pump is made.THE HYDRAULIC CHARACTERISTICS OF THESE PUMPS,TOGETHER WITH THEIR COMPACTNESS, MAKE THEM SUITABLEFOR USE IN THE industrial SECTOR. The pumps must be installed inenclosed places, or at least protected against inclement weather.
• PUMP BODY: cast iron, with threaded ports.
• PUMP BODY: brass for PQHH 05
• MOTOR BRACKET (patent nº 1289150): aluminium with brass insert; reduces starting difficulties due to seizure of the impeller after long periods of inactivity.
• IMPELLER: brass, of the type with radial peripheral vanes.
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• MECHANICAL SEAL: ceramic - graphite - NBR.
• ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty.PQ: single-phase 115 V or 230 V - 60 Hz with capacitor and
thermal overload protector.PQ: three-phase 230/460 V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 44.
• REGISTERED MODEL nº 72753
⇒ pump shaft in stainless steel EN 10088-3 - 1.4401 (AISI 316)⇒ special mechanical seal⇒ protection IP 55⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
PQ pumps with peripheral impellerrecommended for industrial uses
CONSTRUCTION AND SAFETY STANDARDS
EN 60034-1IEC 34-1CEI 2-3
5
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MODELHP
FLOW RATE GPM 0 1.2 2.7 4 5.2 6.6 8 9.3 10.2 13.2 15.8 18.5 21 23
1 PH 3 PH FLOW RATE l/min 0 5 10 15 20 25 30 35 40 50 60 70 80 90PQ 03 PQ 03 0.33
H Feet
131 125 110 95 79 64 49 33 16
PQ 05 PQ 05 0.5 181 164 149 133 118 102 89 72 56 26
PQH 05 PQH 05 0.5 214 204 187 171 154 138 122 105 89 59
PQ 07 PQ 07 0.7 230 217 200 184 168 151 135 120 102 72
PQH 07 PQH 07 0.7 296 269 233 197 161 125 89 56 16
PQ 10 PQ 10 1 279 263 246 230 214 197 181 164 148 115 82 49
PQ 15 PQ 15 1.5 296 283 266 250 233 215 197 181 164 131 99 66 33
PQ 20 2 329 312 279 263 246 230 214 197 164 131 99 66 33
MODELHP
FLOW RATE GPM 0 0.5 1 1.5 2 2.8 3 3.3 4 4.8
1 PH 3 PH FLOW RATE l/min 0 2 4 6 8 10 12 14 16 18PQHH 05 PQHH 05 0.5
H Feet296 263 233 207 177 148 122 92 62 33
PQHH 05 - Bs PQHH 05-Bs 0.5 296 263 233 207 177 148 122 92 62 33
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN1 DN2 a f h h1 h2 h3 i m n n1 w s 1~ 3~PQ 03 PQ 03 1" 1" 0.9 8.8 6.0 4.3 1.2 5.4 3.1 3.1 4.7 3.9 2.2 0.3 11.7 11.7
PQ 05 PQ 05 1" 1" 0.9 9.21/8.93 6.0 4.4 1.2 5.6 3.1 3.1 4.7 3.9 2.2 0.3 15.6 13.9
PQH 05 PQH 05 1" 1" 0.9 10.0 7.0 4.8 1.2 5.9 3.3 3.5 5.4 4.4 2.4 0.3 21.8 19.6
PQHH 05 PQHH 05 1/2” 1/2” 0.7 8.93/8.66 6.0 4.6 0.9 5.6 2.8 3.1 4.7 3.9 2.3 0.3 14.8 15.0
PQHH 05-Bs PQHH 05-Bs 1/2” 1/2” 0.9 8.93/8.66 7.0 5.0 1.1 6.0 3.3 3.5 5.4 4.4 2.4 0.3 15.0 15.0
PQ 07 PQ 07 1" 1" 0.9 10.0 7.0 4.8 1.2 5.9 3.3 3.5 5.4 4.4 2.4 0.3 22.1 19.4
PQH 07 PQH 07 3/4” 3/4” 0.7 10.0 7.0 5.0 1.1 6.0 3.3 3.5 5.4 4.4 2.4 0.3 22.1 19.8
PQ 10 PQ 10 1" 1" 1.0 12.5 8.3 5.5 1.2 6.7 3.5 3.9 6.2 4.9 3.3 0.4 32.7 31.6
PQ 15 PQ 15 1" 1" 1.0 12.5 8.3 5.5 1.2 6.7 3.5 3.9 6.2 4.9 3.3 0.4 34.7 32.7
PQ 20 1" 1" 1.0 12.5 8.3 5.5 1.2 6.7 3.5 3.9 6.2 4.9 3.3 0.4 34.7
f
a w ms
DN2i
n1n
DN
1
h3 h
h1
h2
6
Flow rate up to 13 gpmHead up to 590 ft
Manometric suction lift up to 26 ftLiquid temperature up to + 194°FEnvironment temperature up to + 104°F
It is recommended for pumping clean water without abrasive particlesand liquids that are chemically non aggressive to the materials fromwhich the pump is made. THE HYDRAULIC CHARACTERISTICS OFTHIS PUMP, TOGETHER WITH ITS COMPACTNESS ANDSTURDINESS, MAKE IT SUITABLE FOR USE IN THE industrialSECTOR. The pump must be installed in enclosed places, or at leastprotected against inclement weather.
• PUMP BODY: cast iron, with threaded ports.
• BODY BACK-PLATE: brass with front shim disk in stainless steel.
• MOTOR BRACKET (patent nº 1289150): aluminium with brass and stainless steel insert; eliminates seizure of the impeller after long periods of inactivity.
• IMPELLER: bronze, of the type with radial peripheral vanes.
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• MECHANICAL SEAL: ceramic - graphite - NBR.
• ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty.PQH 20: three-phase 230V - 60 Hz.
• INSULATION: class H. • PROTECTION: IP 55.
⇒ pump shaft in stainless steel EN 10088-3 - 1.4401 (AISI 316)⇒ special mechanical seal⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of use
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
PQH 20 pump with peripheral impellerfor industrial uses
CONSTRUCTION AND SAFETY STANDARDS
EN 60034-1IEC 34-1CEI 2-3
7
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MODELHP
FLOW RATE GPM 0 2.7 4 5.2 6.6 8 9.3 10.2 11.9 13.2
3 PH FLOW RATE l/min 0 10 15 20 25 30 35 40 45 50PQH 20 2 H feet 590 525 476 433 387 344 302 256 208 164
MODEL SUCTION / DISCH DIMENSIONS INCHES LBS3 PH DN1 DN2 a f h h1 h2 h3 i m n n1 w s 3~
PQH 20 3/4" 3/4" 1.3 12.9 8.3 5.5 1.4 7.0 2.5 3.9 6.5 4.9 3.8 0.3 42.0
f
a w ms
DN2
i
n1
n
DN
1
h3
h
h1
h2
8
Flow rate up to 13 gpmHead up to 295 ft
Manometric suction lift up to 26 ftLiquid temperature up to + 194°FEnvironment temperature up to + 104°F
They are recommended for pumping clean water without abrasiveparticles and liquids that are chemically non aggressive to the materialsfrom which the pump is made. NON-FERROUS CONSTRUCTION WITHWETTED PARTS IN HIGH PERFORMANCE TECHNOPOLYMER ANDBRASS TO ELIMINATE THE POSSIBILITY OF CORROSION.CONSEQUENTLY THEY ARE RECOMMENDED FOR INDUSTRIALAPPLICATIONS INCLUDING COOLING, CONDITIONING ANDBOILER FEED.The pumps must be installed in enclosed places, or at least protectedagainst inclement weather.
• PUMP BODY: high-performance technopolymer with metal threaded port insert for secure pipe connection without damage to the pump body.
• BODY BACK-PLATE: brass.
• MOTOR BRACKET (patent nº 1289150): aluminium with brass insert; eliminates seizure of the impeller after long periods of inactivity.
• IMPELLER: brass, of the type with radial peripheral vanes.
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• MECHANICAL SEAL: ceramic - graphite - NBR.
• ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty.PQA: single-phase 115 V or 230 V - 60 Hz with capacitor and
thermal overload protector.PQA: three-phase 230/460 V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 44.
• REGISTERED MODEL
⇒ pump shaft in stainless steel EN 10088-3 - 1.4401 (AISI 316)⇒ special mechanical seal⇒ protection IP 55⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
PQA pumps with peripheral impellerrecommended for industrial applications
CONSTRUCTION AND SAFETY STANDARDS
EN 60034-1IEC 34-1CEI 2-3
9
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN1 DN2 a f h h1 h2 h3 i m n n1 w s 1~ 3~
PQA 03 PQA 03 1/2" 1/2" 1.0 8.9 6.0 4.1 1.3 5.4 2.9 3.1 4.7 3.9 2.2 0.3 10.6 10.6
PQA 05 PQA 05 1/2" 1/2" 1.1 10.2 7.0 4.6 1.3 5.9 2.9 3.5 5.4 4.4 2.4 0.3 22.7 20.5
PQAH 05 PQAH 05 1" 1" 1.1 10.2 7.0 4.8 1.2 5.9 3.3 3.5 5.4 4.4 2.4 0.3 22.9 20.7
PQA 07 PQA 07 1/2" 1/2" 1.1 10.2 7.0 4.6 1.3 5.9 2.9 3.5 5.4 4.4 2.4 0.3 23.2 21.0
PQAH 07 PQAH 07 1" 1" 1.1 10.2 7.0 4.8 1.2 5.9 3.3 3.5 5.4 4.4 2.4 0.3 23.2 21.0
PQAHH 07 PQAHH 07 1/2" 1/2" 1.1 10.1 7.0 4.8 1.4 6.1 3.0 3.5 5.4 4.4 2.4 0.3 23.2 21.0
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
f
a w ms
DN2i
n1n
DN
1
h3 h
h1
h2
MODELHP
FLOW RATE GPM 0 0.5 1.2 2.7 4 5.2 6.6 8 8.5 10 12 13
1 PH 3 PH FLOW RATE l/min 0 2 5 10 15 20 25 30 32 38 45 50PQA 03 PQA 03 0.33
H Feet
131 125 115 95 77 59 41 23 16
PQA 05 PQA 05 0.5 214 204 191 171 149 130 108 89 79 54 26
PQAH 05 PQAH 05 0.5 214 204 187 171 154 138 123 117 97 74 59
PQA 07 PQA 07 0.7 230 217 204 184 163 141 122 102 92 67 39
PQAH 07 PQAH 07 0.7 230 217 200 184 168 151 136 130 123 87 72
PQAHH 07 PQAHH 07 0.7 296 283 260 223 186 149 112 76 61 16
10
Flow rate up to 42 gpmHead up to 190 ft
Manometric suction lift up to 23 ftLiquid temperature up to + 194°FLiquid temperature up to + 104°F in the CPX version (with technopolymer impeller) Environment temperature up to + 104°F
They are recommended for pumping clean water and liquids that arechemically non aggressive to the materials from which the pump is made.RELIABLE AND MAINTENANCE FREE THEY ARE WIDELY USED INTHE DOMESTIC AND CIVIL SECTOR, IN PARTICULAR FOR WATERDISTRIBUTION IN COMBINATION WITH SMALL OR MEDIUMPRESSURE SETS, FOR TRANSFER IN GENERAL, FOR IRRIGATINGGARDENS.The pumps must be installed in enclosed places, or at least protectedagainst inclement weather.
• PUMP BODY: cast iron, with threaded ports.
• BODY BACK-PLATE: stainless steel AISI 304 or cast iron on higher powered models.
• BRASS IMPELLER
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• MECHANICAL SEAL: ceramic - graphite - NBR.
• ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty.CP: single-phase 115 V or 230 V - 60 Hz with capacitor and
thermal overload protector built into the winding.CP: three-phase 230/460 V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 44.
• REGISTERED MODEL nº 72753.
⇒ impeller in technopolymer (CP...X - CP...X)⇒ special mechanical seal⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of use
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
CP centrifugal pumps
CONSTRUCTION AND SAFETY STANDARDS
EN 60034-1IEC 34-1CEI 2-3
11
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MODELHP
FLOW RATE GPM 0 2 5 7 10 13 15 18 21 23 26 29 31 34 37 39 42
1 PH 3 PH FLOW RATE l/min 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160CP 05 CP 05 0.5
H Feet
99 94 89 84 77 69 57 46
CP 07 CP 07 0.7 115 112 108 103 97 89 79 67 56 43
CPH 10 CPH 10 1 138 135 130 126 122 118 113 108 102 95 85 76 61
CPH 15 CPH 15 1.5 158 154 151 148 145 141 138 133 128 120 112 102 89 76
CPH 20 CPH 20 2 187 186 182 181 177 174 169 164 158 151 141 133 123 112 99
CP 10 CP 10 1 128 126 125 122 120 118 115 112 108 105 99 94 87 80 74 66 59
CP 15 CP 15 1.5 141 140 138 135 133 131 128 123 120 115 112 107 102 95 89 82 76
CP 20 CP 20 2.0 168 166 165 164 163 159 156 153 148 145 140 135 130 123 118 112 105
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN1 DN2 a f h h1 n n1 w s s 1~ 3~CP 05 CP 05 1" 1" 1.3 9.7 7.4 3.0 5.8 4.6 1.8 0.4 0.4 15.0 15.2
CP 07 CP 07 1" 1" 1.7 10.5 8.3 3.2 6.5 5.3 1.6 0.4 0.4 18.6 0.0
CPH 10 CPH 10 1 1/4" 1" 1.7 11.7 9.5 3.8 7.5 6.3 1.7 0.4 0.4 26.7 25.6
CPH 15 CPH 15 1 1/4" 1" 2.0 13.4 10.2 4.3 8.1 6.5 1.7 0.4 0.4 42.4 40.9
CPH 20 CPH 20 1 1/4" 1" 2.0 13.4 10.2 4.3 8.1 6.5 1.7 0.4 0.4 55.3 53.5
CP 10 CP 10 1 1/4" 1" 2.0 13.4 10.2 4.3 8.1 6.5 1.7 0.4 0.4 58.1 56.4
CP 15 CP 15 1 1/4" 1" 2.0 13.4 10.2 4.3 8.1 6.5 1.7 0.4 0.4 42.4 40.9
CP 20 CP 20 1 1/4" 1" 2.0 13.4 10.2 4.3 8.1 6.5 1.7 0.4 0.4 55.3 53.5
f
a
w s
DN2
n1
n
DN
1 hh
1h
2
12
Flow rate up to 240 gpmHead up to 246 ft
Manometric suction lift up to 23 ftLiquid temperature up to + 195°F Environment temperature up to + 104°F
They are recommended for pumping clean water and liquids that arechemically non aggressive to the materials from which the pump is made.RELIABLE AND MAINTENANCE FREE THEY ARE WIDELY USED INTHE CIVIL, AGRICULTURAL AND INDUSTRIAL SECTORs, FORSUPPLYING WATER, FOR CONDITIONING OR COOLING SYSTEMS,FOR IRRIGATION, ETC. The pumps must be installed in enclosed places, or at least protectedagainst inclement weather.
• PUMP BODY: cast iron, with threaded ports.
• BODY BACK-PLATE: cast iron.
• IMPELLER: brass for pumps up to 12.5 HP.
• IMPELLER: cast iron for pumps from 15 to 25 HP.
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• MECHANICAL SEAL: ceramic - graphite - NBR.
• ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, with high efficiency (class “EFF1”), quiet running, totally enclosed fan cooled (TEFC), suitablefor continuous duty.CP: three-phase 230/460 V - 60 Hz
• INSULATION: class F. • PROTECTION IP 44.
• REGISTERED MODEL nº 72753
• PATENTED ELECTRIC MOTOR
⇒ pump shaft in stainless steel EN 10088-3 - 1.4401 (AISI 316)⇒ special mechanical seal⇒ protection IP 55⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of use
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
CP
Electric pumps withhigh efficiency motorfor reduced energyconsumption
close-coupled centrifugal pumps with threaded ports
CONSTRUCTION AND SAFETY STANDARDS
EN 60034-1IEC 34-1CEI 2-3
13
GENERAL PERFORMANCE DATA
Hea
d HH
(fee
t)
Flow Rate QQ
Hea
d HH
(met
ers)
CURVES AND PERFORMANCE DATA
Hea
d HH
(fee
t)NN
PPSS
HH(f
eet)
Ab
sorb
ed P
ow
er PP
22(H
P)
NNPP
SSHH
(met
ers)
PP 22(k
W)
Flow Rate QQ
MODELHP
FLOW RATE GPM 0 13 26 39 52 66 79 92 105 119 132 145 158
1 PH 3 PH FLOW RATE l/min 0 50 100 150 200 250 300 350 400 450 500 550 600
CPH 50 CPH 50 5
H Feet
171 169 168 167 165 161 156 148 141 131
CPH 75 7.5 197 197 197 195 196 192 187 181 172 166
CPH 100 10 246 246 245 244 243 241 238 233 225 221 214 206 197
14
Hea
d HH
(met
ers)
15
Hea
d HH
(met
ers)
CURVES AND PERFORMANCE DATA
Hea
d HH
(fee
t)
MODELHP
FLOW RATE GPM 0.0 26 52 79 105 132 158 185 211 238
3 PH FLOW RATE l/min 0 100 200 300 400 500 600 700 800 900
CP 75 7.5
H Feet
168 164 195 158 151 143 131 119 105 90
CP 100 10 186 184 182 177 171 161 149 135 118 100
CP 125 12.5 204 204 202 197 189 179 166 149 130 109
NNPP
SSHH
(fee
t)A
bso
rbed
Po
wer
PP22
(HP
)
NNPP
SSHH
(met
ers)
PP 22(k
W)
Flow Rate QQ
16
CURVES AND PERFORMANCE DATA
MODELHP
FLOW RATE GPM 0 26 52 79 105 132 158 185 211 238
3 PH FLOW RATE l/min 0 100 200 300 400 500 600 700 800 900
CP-CPR 150 15
H Feet
263 263 263 243 227 210 191 171 148 122
CP-CPR 200 20 312 312 312 292 276 260 240 220 197 171
CP-CPR 250 25 361 361 361 342 325 309 289 269 246 220
Hea
d HH
(fee
t)NN
PPSS
HH(f
eet)
Ab
sorb
ed P
ow
er PP
22(H
P)
NNPP
SSHH
(met
ers)
PP22
(kW
)H
ead
HH(m
eter
s)
17
DIMENSIONS AND WEIGHT
f
a
wn1
s
DN2
n
DN
1 h
h1
h2
n2
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN1 DN2 a f h h1 h2 n n1 n2 w s 3~
CPH 50 2" 2" 2.8 19.9 12.9 5.4 7.6 10.7 7.5 9.8 1.6 0.6 105.2
CPH 50 2" 2" 2.8 18.1 12.9 5.4 7.6 10.7 7.5 9.8 1.6 0.6 94.1
CPH 75 2" 2" 2.8 19.9 12.9 5.4 7.6 10.7 7.5 9.8 1.6 0.6 105.2
CPH 100 2" 2" 2.8 19.9 12.9 5.4 7.6 10.7 7.5 9.8 1.6 0.6 114.9
CP 75 2" 2" 2.8 19.9 12.9 5.4 7.6 10.7 7.5 9.8 1.6 0.6 105.2
CP 100 2" 2" 2.8 19.9 12.9 5.4 7.6 10.7 7.5 9.8 1.6 0.6 114.9
CP 125 2" 2" 2.8 19.9 12.9 5.4 7.6 10.7 7.5 9.8 1.6 0.6 116.0
CP 150 2" 2" 2.6 23.5 15.4 6.3 9.1 12.7 9.1 11.6 1.8 0.6 227.6
CP 200 2" 2" 2.6 27.3 15.4 6.3 9.1 12.7 9.1 11.6 1.8 0.6 265.2
CP 250 2" 2" 2.6 27.3 15.4 6.3 9.1 12.7 9.1 11.6 1.8 0.6 293.9
CPR 150 4" 3" 3.6 23.5 15.4 6.3 9.1 12.7 9.1 11.6 1.8 0.6 236.5
CPR 200 4" 3" 3.6 27.3 15.4 6.3 9.1 12.7 9.1 11.6 1.8 0.6 274.0
CPR 250 4" 3" 3.6 27.3 15.4 6.3 9.1 12.7 9.1 11.6 1.8 0.6 302.8
18
Maximum flow rate 47 gpmMaximum head 105 ft
Manometric suction lift up to 23 ftLiquid temperature up to + 195°FEnvironment temperature up to + 130°F
It is recommended for pumping clean water and liquids that arechemically non aggressive to the materials from which the pump is made.THE CONSTRUCTION OF THESE CENTRIFUGAL PUMPS MAKESTHEM SUITABLE FOR USE IN THE DOMESTIC, AGRICULTURALAND INDUSTRIAL SECTOR. ALL THE WETTED PARTS ARE INSTAINLESS STEEL AISI 340 TO GUARANTEE TOTAL HYGIENEAND MAXIMUM RESISTANCE TO CORROSION.The pump must be installed in enclosed places, or at least protectedagainst inclement weather.
• PUMP BODY: stainless steel AISI 304, with threaded ports.
• BODY BACK-PLATE AND DIFFUSER: AISI 304.
• IMPELLER: stainless steel AISI 304, of the type with centrifugal radial flow.
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• MECHANICAL SEAL: ceramic - graphite - NBR.
• ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty.AR 10: single-phase 115 V or 230 V - 60 Hz with capacitor
and thermal overload protector.AR 10: three-phase 230/460 V - 60 Hz.
• INSULATION : class F. • PROTECTION: IP 44.
• REGISTERED MODEL nº 72753.
⇒ version in stainless steel EN 10088-3 - 1.4401 (AISI 316)⇒ special mechanical seal⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
AR stainless steel centrifugal pump
CONSTRUCTION AND SAFETY STANDARDS
EN 60034-1IEC 34-1CEI 2-3
19
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MODELHP
FLOW RATE GPM 0 5 7 10 13 15 18 21 23 26 29 31 34 37 39 42 45 47
1 PH 3 PH FLOW RATE l/min 0 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180AR 10 AR 10 1.0 H Feet 105 102 101 100 99 97 95 92 90 87 83 80 76 72 68 63 58 53
MODEL SUCTION /DISCH DIMENSIONS INCHES WEIGHT1 PH 3 PH DN1 DN2 a f h h1 h2 h3 n n1 w s LBSAR 10 AR 10 1 1/4" 1" 1.2 11.6 8.1 3.8 4.1 7.9 7.2 4.5 3.7 0.4 20.1
f
a
ws
DN2
n
n1
n1
n
DN
1
h3h
h1
h2
20
Flow rate up to 92 gpmHead up to 66 ft
Manometric suction lift up to 23 ftLiquid temperature up to + 194°F Environment temperature up to + 104°F Passage of solid bodies Ø 4/10”
They are recommended for pumping water and liquids that arechemically non aggressive to the materials from which the pump is made. THE OPEN IMPELLER DESIGN ALLOWS THE PUMPING OFLIQUIDS WITH RELATIVELY HIGH LEVELS OF IMPURITIESWITHOUT RISK OF CLOGGING THE IMPELLER. FOR THIS REASONTHE PRO-NGA SERIES ARE SUITABLE FOR USE IN SYSTEMS FORWASHING FRUIT, VEGETABLES, FISH, SHELLFISH, MEAT, ININDUSTRIAL SYSTEMS FOR WASHING METAL PARTS, GLASSCONTAINERS, AND FOR THE CIRCULATION OF COOLING LIQUIDS.The pumps must be installed in enclosed places, or at least protectedagainst inclement weather.
• PUMP BODY: stainless steel AISI 316, with threaded ports.
• BODY BACK-PLATE: stainless steel AISI 316.
• OPEN IMPELLER: stainless steel AISI 316.
• MOTOR SHAFT: stainless steel AISI 316.
• MECHANICAL SEAL: ceramic - graphite - viton - AISI 316
• ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty.PNGA: single-phase 115 V or 230 V - 60 Hz with capacitor
and thermal overload protector.PNGA: three-phase 230/460 V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 44.
⇒ special mechanical seal⇒ other voltages or frequency 50 Hz⇒ protection IP 55
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
PNGA
Centrifugal pumps madeof stainless steel AISI316, equipped with anopen impeller, ideal fortransferring liquidscontaining impurities.
stainless steel pumps
CONSTRUCTION AND SAFETY STANDARDS
EN 60034-1IEC 34-1CEI 2-3
21
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MODELHP
FLOW RATE GPM 0 13 26 39 52 66 79 86 92
1 PH 3 PH FLOW RATE l/min 0 50 100 150 200 250 300 325 350PNGA 05 PNGA 05 0.5
H Feet59 56 53 48 43 34 26 20
PNGA 07 PNGA 07 0.7 66 64 59 54 49 41 33 26 20
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN1 DN2 a f h h1 h2 n n1 w s 1~ 3~
PNGA 05 PNGA 05 1 1/2" 1 1/2" 1.6 11.7 8.9 3.6 5.3 7.5 6.3 2.0 0.4 28.7 26.5
PNGA 07 PNGA 07 1 1/2" 1 1/2" 1.6 11.7 8.9 3.6 5.3 7.5 6.3 2.0 0.4 29.0 26.7
fa
w n1s
DN2
n
DN
1 h
h1
h2
22
Flow rate up to 34 gpmHead up to 164 ft
Manometric suction lift up to 23 ftLiquid temperature up to + 104°F Environment temperature up to+ 104°F
They are recommended for pumping clean water and liquids that arechemically non aggressive to the materials from which the pump is made.DUE TO THEIR RELIABILITY, QUIET RUNNING AND LOWMAINTENANCE, THEY ARE SUITABLE FOR DOMESTICAPPLICATIONS INCLUDING WATER SUPPLIES (AS A PRESSURESET), GARDEN IRRIGATION, ETC.The pumps must be installed in enclosed places, or at least protectedagainst inclement weather.
• PUMP BODY: cast iron, with threaded ports.
• BODY BACK-PLATE: stainless steel AISI 304.
• IMPELLERS: of the type with centrifugal radial flow, made of technopolymer (approved for drinking water).
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104
• MECHANICAL SEAL: ceramic - graphite - NBR.
• ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty.3-4CP: single-phase 115 V or 230 V - 60 Hz with capacitor
and thermal overload protector.3-4CP: three-phase 230/460 V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 44.
• REGISTERED MODEL
⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
3-4CP
Particularly quietrunning with highefficiency and lowpower consumption.Suitable for domesticapplications.
multi-stage centrifugal pumps
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
23
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MODELHP
FLOW RATE GPM 0 1 2 3 5 6 7 10 13 15 18 21 23 26 29 31 34
1 PH 3 PH FLOW RATE l/min 0 5 10 15 20 25 30 40 50 60 70 80 90 100 110 120 1303CP 04 3CP 04 0.4
H Feet
125 118 115 112 110 102 95 82 66 51 33 16
4CP 05 4CP 05 0.5 164 158 154 148 141 133 126 110 92 74 53 33
3CP 05 3CP 05 0.5 118 117 115 112 110 107 105 99 92 85 76 66 56 44 33 16
4CP 07 4CP 07 0.7 151 148 145 141 138 135 131 125 117 108 99 87 74 62 49 33 16
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN1 DN2 a f h h1 h2 n n1 w s 1~ 3~
3CP 04 3CP 04 1" 1" 4.3 13.1 6.8 5.3 1.5 6.2 4.6 0.1 0.4 19 19
4CP 05 4CP 05 1" 1" 5.3 14.5 / 14.2 6.8 5.3 1.5 6.2 4.6 0.1 0.4 20.8 19.7
3CP 05 3CP 05 1" 1" 4.3 13.5 / 13.2 6.8 5.3 1.5 6.2 4.6 0.1 0.4 23.9 22.5
4CP 07 4CP 07 1" 1" 5.3 14.9 7.5 5.3 2.4 6.2 4.6 0.1 0.4 22.5 20.8
f
a
w
n1
s
DN2
n
DN
1
h
h1
h2
24
Flow rate up to 31 gpmHead up to 164 ft
Manometric suction lift up to 23 ftLiquid temperature up to + 104°F Environment temperature up to + 104°F
They are recommended for pumping clean water and liquids that arechemically non aggressive to the materials from which the pump is made.DUE TO THEIR RELIABILITY AND QUIET RUNNING, THEY ARESUITABLE FOR RESIDENTIAL APPLICATIONS INCLUDINGWATER SUPPLIES (AS A PRESSURE SET), GARDENIRRIGATION, ETC.The pumps must be installed in enclosed places, or at least protectedagainst inclement weather.
• PUMP BODY: stainless steel AISI 304, with threaded ports.
• BODY BACK-PLATE: stainless steel AISI 304.
• IMPELLERS: of the type with centrifugal radial flow, made of technopolymer (approved for drinking water).
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• MECHANICAL SEAL: ceramic - graphite - NBR.
• ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty.3-4CR: single-phase 115 V or 230 V - 60 Hz with capacitor and
thermal overload protector.3-4CR: three-phase 230/460 V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 44
.
⇒ special mechanical seal⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
3-4CR
Particularly quietrunning with highefficiency and lowpower consumption.Suitable for domesticapplications.
multi-stage centrifugal pumpsstainless steel pump body
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
25
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d H
(fee
t)
Hea
d H
(met
ers)
Flow Rate Q
MODELHP
FLOW RATE GPM 0 1 2 3 5 6 7 10 13 15 18 21 23 26 29 31
1 PH 3 PH FLOW RATE l/min 0 5 10 15 20 25 30 40 50 60 70 80 90 100 110 1203CR 04 3CR 04 0.4
H Feet
125 118 115 112 107 102 95 82 66 51 33 16
4CR 05 4CR 05 0.5 164 158 154 148 141 133 126 110 110 92 74 53 33
3CR 05 3CR 05 0.5 118 117 115 112 110 107 105 99 92 84 76 66 56 44 33 16
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN1 DN2 a f h h1 h2 n n1 w s 1~ 3~
3CR 04 3CR 04 1" 1" 3.5 13.6 6.9 4.8 2.0 6.3 4.7 3.7 0.4 15.2 13.9
4CR 05 4CR 05 1" 1" 3.5 13.9 /13.6 6.9 4.8 2.0 6.3 4.7 3.7 0.4 16.8 15.2
3CR 05 3CR 05 1" 1" 3.5 13.9 /13.7 6.9 4.8 2.0 6.3 4.7 3.7 0.4 16.5 15.2
f
a
w s
DN2
n1
n
DN
1
h
h1
h2
26
Flow rate up to 23 gpmHead up to 348 ft
Manometric suction lift up to 23 ftLiquid temperature up to 104°f
They are recommended for pumping clean water and liquids that arechemically non aggressiveto to the materials from which the pump is made.THEIR RELIABILITY AND QUIET RUNNING MAKE THEM SUITABLEFOR DOMESTIC AND CIVIL APPLICATIONS, BECAUSE THE PUMPIS FULLY SUBMERSIBLE WITH THE MOTOR COOLED BY THEPUMPED LIQUID, IT CAN BE USED SAFELY IN WETENVIRONMENTS AND IN SPACES WITH INSUFFICIENTVENTILATION.
• OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304 case with threaded ports.
• IMPELLERS AND DIFFUSERS: technopolymer.
• DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings.
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• DOUBLE SEAL: mechanical seal silicon carbide-NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running.
• SCREWS: stainless steel AISI 304.
• MOTOR: electric, asynchronous for continuous duty. VL: single-phase 230V - 60 Hz with thermal overload protector
built into windings below 1.5 Hp. The 2 Hp motor has anexternal (with manual reset) incorporated into the control box.
VL: three-phase 230V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 68.
STANDARD FEATURES:
VVLL 1188GG (single-phase) 6 ft power cable type “H07 RN-F” with removable connector.Control box with capacitor
VVLL 1188GG (three-phase) 6 ft power cable type “H07 RN-F” with removable connector.
⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
VL 18G
Robust vertical multi-stagepumps in stainless steel,distinguished by their highefficiency and particularlyquiet operation.
vertical multi-stage pumps
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
27
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Flow Rate QQ
Hea
d HH
(met
ers)
MODELHP
FLOW RATE GPM 0 2 5 7 10 11 13 14 15 17 18 19 21 22 23
1 PH 3 PH FLOW RATE l/min 0 10 20 30 40 45 50 55 60 65 70 75 80 85 90VL18G 15 1.5
HH Feet
283 276 269 256 243 237 230 220 210 200 191 177 164 151 138
VL18G 20 VL18G 20 2.0 329 319 306 289 273 263 253 240 230 217 207 194 179 164 151
VL18GH 20 VL18GH 20 2.0 348 340 329 315 299 289 279 269 260 243 233 214 204 184 164
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS
1 PH 3 PH DN1 DN2 No STAGES a b c d f h (1~) h (3~) h (1) h2(1~) h2 (3~) n w1 w2 s 1~ 3~
VL18G15
1 1/2" 1 1/4"
4
3.9 3.1 7.8 2.6 8.7
22.523.7
2.3
20.121.3
7.2 2.4 3.4 0.4
50.8
VL18G20 VL18G205
23.7 21.3 53.3 49.5
VL18GH20 VL18GH20 26.6 23.7 24.3 21.3 65.9 53.3
d
c
SINGLE-PHASE CONTROL BOX
b
a
w1s
DN2
fn
DN
1
h
h1
h2
w1 w2 w2
28
Flow rate up to 34 gpmHead up to 296 ft
Manometric suction lift up to 23 ftLiquid temperature up to 104°f
They are recommended for pumping clean water and liquids thatare chemically non aggressive to the materials from which thepump is made.THEIR RELIABILITY AND QUIET RUNNING MAKE THEM SUITABLEFOR DOMESTIC AND CIVIL APPLICATIONS, BECAUSE THE PUMPIS FULLY SUBMERSIBLE WITH THE MOTOR COOLED BY THEPUMPED LIQUID, IT CAN BE USED SAFELY IN WETENVIRONMENTS AND IN SPACES WITH INSUFFICIENTVENTILATION.
• OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304 case with threaded ports.
• IMPELLERS AND DIFFUSERS: technopolymer.• DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings.• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.• DOUBLE SEAL: mechanical seal silicon carbide-NBR, with oil barrier
chamber and inner lip seal to protect the seal in the event of dry running.• SCREWS: stainless steel AISI 304.• MOTOR: electric, asynchronous for continuous duty.
VL 25G: single-phase 230V - 60 Hz with thermal overload protector built into windings below 1.5 Hp. The 2 Hp motor has an external overload protector (with manual reset) incorporated into the control box.
VL 25G: three-phase 230V - 60 Hz.• INSULATION: class F. • PROTECTION: IP 68.
STANDARD FEATURES:
VVLL 2255GG (single-phase ) 6 ft power cable type“H07 RN-F” with removable connector.Control box with capacitor.
VVLL 2255GG (three-phase ) 6 ft power cable type “H07 RN-F” with removable connector.
⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
VL 25G vertical multi-stage pumps
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
Robust vertical multi-stage pumps instainless steel,distinguished by theirhigh efficiency andparticularly quietoperation.
29
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Flow Rate QQ
Hea
d HH
(met
ers)
MODELHP
FLOW RATE GPM 0 2 5 7 10 13 15 18 21 23 26 29 31 34
1 PH 3 PH FLOW RATE l/min 0 10 20 30 40 50 60 70 80 90 100 110 120 130VL25G 15 1.5
H Feet
223 220 217 210 204 195 187 176 164 151 135 122 105 89
VL25G 20 VL 25G 20 2.0 263 260 253 246 240 233 223 214 204 191 177 161 145 125
VL25GH 20 VL 25GH 20 2.0 296 292 289 283 276 269 263 253 246 237 223 210 195 177
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS
1 PH 3 PH DN1 DN2 No STAGES a b c d f h (1~) h (3~) h (1) h2(1~) h2 (3~) n w1 w2 s 1~ 3~
VL25G15
1 1/2" 1 1/4"
4
125.4 106.4 225.4 91.4 248.4
22.523.7
2.3
20.121.3
7.2 2.4 3.4 0.4
50.8
VL25G 20 VL25G 20 5 23.7 21.3 53.3 49.5
VL25G H20 VL25G H20 4 25.5 22.5 23.1 20.1 63.9 51.3
d
c
SINGLE-PHASE CONTROL BOX
b
a
w1s
DN2
fn
DN
1
h
h1
h2
w1 w2 w2
30
Maximum flow rate 23 gpmHead up to 348 ft
Manometric suction lift up to 23 ftLiquid temperature up to 104°f
They are recommended for pumping clean water and liquids that arechemically non aggressive to the materials from which the pump is made.THEIR RELIABILITY AND QUIET RUNNING MAKE THEM SUITABLEFOR DOMESTIC AND CIVIL APPLICATIONS AND, BECAUSE THEPUMP IS FULLY SUBMERSIBLE WITH THE MOTOR COOLED BYTHE PUMPED LIQUID, IT CAN BE USED SAFELY IN WET AREASAND IN SPACES WITH INSUFFICIENT VENTILATION. THEENCLOSED DESIGN ALSO ELIMINATES THE POSSIBILITY OFWATER ESCAPING AS A RESULT OF SEAL FAILURE, MAKING ITSUITABLE FOR USE IN CARPETED OR OTHER DELICATEENVIRONMENTS.
• OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304 case with threaded ports.
• IMPELLERS AND DIFFUSORS: technopolymer.
• DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings.
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• DOUBLE SEAL: mechanical seal silicon carbide-NBR, with oil barrier chamberand inner lip seal to protect the seal in the event of dry running.
• SCREWS: stainless steel AISI 304.
• MOTOR: electric, asynchronous for continuous duty.VLE: single-phase 230V - 60 Hz with thermal overload protector built
into windings below 1.5 Hp. The 2 Hp motor has an external overload protector (with manual reset) incorporated into the control box.
VLE: three-phase 230V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 68.
STANDARD FEATURES:
VVLLEE 1188GG (single-phase) 6 ft power cable type“H07 RN-F” with removable connector.Control box with capacitor.
VVLLEE 1188GG (three-phase) 6 ft power cable type “H07 RN-F” with removable connector.
⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
VLE 18G
Compact multi-stage pumps, instainless steel, with suction anddelivery ports “in line”. They can beinstalled in a horizontal or verticalposition, or completely submerged. Theenclosed design also eliminates anypossibility of water escaping.
“in-line” multi-stage pumps
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
31
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Flow Rate QQ
Hea
d HH
(met
ers)
MODELHP
FLOW RATE GPM 0 2 5 7 10 11 13 14 15 17 18 19 21 22 23
1 PH 3 PH FLOW RATE l/min 0 10 20 30 40 45 50 55 60 65 70 75 80 85 90VLE18G 15 1.5
H Feet
283 276 269 256 243 237 230 220 210 200 191 177 164 151 138
VLE18G 20 VLE18G 20 2.0 329 319 306 289 273 263 253 240 230 217 207 194 179 164 151
VLE18GH 20 VLE18GH 20 2.0 348 340 329 315 299 289 279 269 260 243 233 214 204 184 164
MODEL SUCTION /DISCHNo STAGES
DIMENSIONS INCHES LBS1 PH 3 PH DN Ø h (1~) h (3~) a b c 1~ 3~
VLE18G 151 1/4"
4
6.0
20.3 -
3.1 7.8 2.5
43.1 -
VLE18G 20 VLE18G 205
21.5 21.5 45.5 41.8
VLE18G H20 VLE18G H20 24.4 21.5 58.1 45.5
c
h
b
SINGLE-PHASE CONTROL BOX
a
DN2
DN1
DN
2
DN
1
Horizontal installationVertical installation
h
Ø
Ø
32
Flow rate up to 34 gpmHead up to 296 ft
Manometric suction lift up to 25 ftLiquid temperature up to 104°f
They are recommended for pumping clean water and liquids thatare chemically non aggressive to the materials from which thepump is made.THEIR RELIABILITY AND QUIET RUNNING MAKE THEM SUITABLEFOR DOMESTIC AND CIVIL APPLICATIONS AND, BECAUSE THEPUMP IS FULLY SUBMERSIBLE WITH THE MOTOR COOLED BYTHE PUMPED LIQUID, IT CAN BE USED SAFELY IN WET AREASAND IN SPACES WITH INSUFFICIENT VENTILATION. THEENCLOSED DESIGN ALSO ELIMINATES THE POSSIBILITY OFWATER ESCAPING AS A RESULT OF SEAL FAILURE, MAKING ITSUITABLE FOR USE IN CARPETED OR OTHER DELICATEENVIRONMENTS.
• OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304 case with threaded ports
• IMPELLERS AND DIFFUSERS: technopolymer.• DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings.• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.• DOUBLE SEAL: mechanical seal silicon carbide-NBR, with oil barrier
chamber and inner lip seal to protect the seal in the event of dry running.• SCREWS: stainless steel AISI 304.• MOTOR: electric, asynchronous for continuous duty.
VLE 25G: single-phase 230V - 60 Hz with thermal overload protector built into windings below 1.5 Hp. The 2 Hp motor has an external overload protector (with manual reset) incorporated into the control box.
VLE 25G: three-phase 230V - 60 Hz.• INSULATION: class F. • PROTECTION: IP 68.
STANDARD FEATURES:
VLE 25G (single-phase) 6 ft power cable type “H07 RN-F” with removable connector.Control box with capacitor
VLE 25G (three-phase) 6 ft power cable type “H07 RN-F” with removable connector.
⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
VLE25G
Compact multi-stage pumps instainless steel, with suction anddelivery ports “in line”. They can beinstalled in a horizontal or verticalposition or when completelysubmerged. The enclosed designalso eliminates any possibility ofwater escaping.
“in-line” multi-stage pumps
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
33
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Flow Rate QQ
Hea
d HH
(met
ers)
MODELHP
FLOW RATE GPM 0 2 5 7 10 13 15 18 21 23 26 29 31 34
1 PH 3 PH FLOW RATE l/min 0 10 20 30 40 50 60 70 80 90 100 110 120 130VLE25G 15 1.5
H Feet
223 220 217 210 204 195 187 176 164 151 135 122 105 89
VLE25G 20 VLE25G 20 2.0 263 260 253 246 240 233 223 214 204 191 177 161 145 125
VLE25GH 20 VLE25GH 20 2.0 296 292 289 283 276 269 263 253 246 237 223 210 195 177
MODEL SUCTION /DISCHNo STAGES
DIMENSIONS INCHES LBS1 PH 3 PH DN Ø h 1~ h 3~ a b c 1~ 3~
VLE25G 151 1/4"
4
6.0
20.321.5
3.2 7.9 2.6
43.1
VLE25G 20 VLE25G 205
21.5 45.5 41.8
VLE25GH 20 VLE25GH 20 23.3 20.3 56.1 43.5
c
h
h
b
SINGLE-PHASE CONTROL BOX
a
DN2
DN
1
DN1
DN
2
Horizontal installationVertical installation
Ø
Ø
34
Flow rate up to 13 gpmHead up to 330 ft
Manometric suction lift up to 29 ftLiquid temperature up to + 140°FEnvironment temperature up to + 104°F
They are recommended for pumping clean water without abrasive particlesand liquids that are chemically non aggressive to the materials from whichthe pump is made.FOR THEIR COMPACTNESS, RELIABILITY AND ECONOMY THEYARE SUITABLE FOR DOMESTIC USE AND IN PARTICULAR FORDISTRIBUTING WATER IN COMBINATION WITH SMALL PRESSURESETS, FOR IRRIGATING GARDENS, DRAWING WATER FROM TANKSOR WELLS DOWN TO A DEPTH OF 27 FEET AND IN ALL CASESWHERE THERE IS THE PRESENCE OF AIR OR GAS IN THE LIQUID TOBE PUMPED; the pump is provided with a check flap valve on the intake sothat it is no longer necessary to fit a foot valve. The pumps must be installedin enclosed places, or at least protected against inclement weather.
• PUMP BODY: cast iron, with threaded ports.
• CHECK FLAP VALVE: incorporated in the suction port.
• MOTOR BRACKET (patent nº 1289150): aluminium with brass insert; reduces starting difficulties due to seizure of the impeller after long periods of inactivity.
• IMPELLER: brass, of the type with radial peripheral vanes.
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• MECHANICAL SEAL: ceramic - graphite - NBR.
• ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty.
PKS: single-phase 115 V or 230 V - 60 Hz with capacitor and thermal overload protector.
PKS: three-phase 230/460 V - 60 Hz
• INSULATION: class F. • PROTECTION: IP 44.
• REGISTERED MODEL nº 72753.
⇒ special mechanical seal⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
PKS self-priming pumps with peripheral impeller
CONSTRUCTION AND SAFETY STANDARDS
EN 60034-1IEC 34-1CEI 2-3
35
CURVES AND PERFORMANCE DATA
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MODELHP
FLOW RATE GPM 0 1.2 2.7 4 5.5 6.6 8 9.3 10.2 11.9 13.2
1 PH 3 PH FLOW RATE l/min 0 5 10 15 20 25 30 35 40 45 50
PKS 03 PKS 03 0.33
H feet
131 125 110 95 79 64 49 33 16
PKS 05 PKS 05 0.5 180 164 149 133 118 102 89 72 56 41 26
PKSH 05 PKSH 05 0.5 213 203 187 171 154 138 121 105 89 72 59
PKS 07 PKS 07 0.7 230 216 200 184 167 151 134 120 102 89 72
DIMENSIONS AND WEIGHT
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN1 DN2 a f h h1 h2 h3 i m n k n1 w S 1~ 3~
PKS 03 PKS 03 1" 1" 1.1 9.1 7.5 6.1 1.3 7.4 4.3 3.1 5.9 4.7 3.9 2.1 0.2 13.4 13.4
PKS 05 PKS 05 1" 1" 1.1 9.4/ 9.0 7.5 6.1 1.3 7.4 4.3 3.1 5.9 4.7 3.9 2.1 0.2 17.0 15.6
PKSH 05 PKSH 05 1" 1" 1.1 10.2 7.8 6.4 1.3 7.7 4.3 3.5 6.2 5.4 4.4 2.4 0.2 23.6 21.2
PKS 07 PKS 07 1" 1" 1.1 10.2 7.8 6.4 1.3 7.7 4.3 3.5 6.2 5.4 4.4 2.4 0.2 23.8 21.4
f
a w ms
DN2 ik
n1
n
DN
1
h3h h1
h2
36
Flow rate up to 13 gpmHead up to 154 ft
Manometric suction lift up to 29 ftLiquid temperature up to + 104°F Environment temperature up to + 104°F
They are recommended for pumping clean water and liquids that arechemically non aggressive to the materials from which the pump is made. JSW SELF-PRIMING PUMPS ARE DESIGNED FOR SUCTION LIFTSAND CAN BE POSITIONED ABOVE THE WATER SOURCE,INCLUDING APPLICATIONS WITH AIR ENTRAINED IN THE WATER.DUE TO THEIR RELIABILITY AND LOW MAINTENANCE, THEYARE RECOMMENDED FOR RESIDENTIAL USE, INCLUDINGWATER DISTRIBUTION (AS PART OF A PRESSURE SET), GARDENIRRIGATION, ETC.The pumps must be installed in enclosed places, or at least protectedagainst inclement weather.
• PUMP BODY: cast iron, with threaded ports.
• BODY BACK-PLATE: stainless steel AISI 304.
• EJECTOR ASSEMBLY: technopolymer (approved for drinking water).
• IMPELLER: technopolymer up to 1 HP.
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• MECHANICAL SEAL: ceramic - graphite -NBR.
• ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty.JSW: single-phase 115 V or 230 V - 60 Hz with capacitor and
thermal overload protector.JSW: three-phase 230/460 V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 44.
• REGISTERED MODEL nº 72753.
⇒ impeller in technopolymer (JSW...X - JSW...X)⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
JSW “Shallow Well” self-priming jet pumps
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
37
CURVES AND PERFORMANCE DATA
Suction Lift
Depth (feet)
Discharge Pressure - PSIMax Shut OFF
PSI 30 40 50 60
Discharge Capacity US GPM5 12 8 5 2 7010 11 6.5 4 1.5 6815 10.5 6.5 3.5 1 65.5 20 8.5 5.5 3 0.5 62.5
25 8 5 2.5 61.5
Suction Lift
Depth (feet)
Discharge Pressure - PSIMax Shut OFF
PSI 30 40 50 60
Discharge Capacity US GPM5 14 13 8.5 6 80
10 13 12 8 5 78
15 12 11 7 4 76
20 10 9 6 3 74
25 9 7 5 2 72
Suction Lift
Depth (feet)
Discharge Pressure - PSIMax Shut OFF
PSI 30 40 50 60
Discharge Capacity US GPM5 21 20 7 2 6510 18.5 11 6.5 1,5 6315 16.2 10 5.3 6120 14.9 8 2.9 59
25 7.2 5.5 1.5 57
Suction Lift
Depth (feet)
Discharge Pressure - PSIMax Shut OFF
PSI 30 40 50 60
Discharge Capacity US GPM5 22 21 15.8 10 7910 22 21 14.5 8.5 7715 21 20 12.6 7.2 7520 20 18.5 10.5 5 73
25 20 18 10.3 4 71
Suction Lift
Depth (feet)
Discharge Pressure - PSIMax Shut OFF
PSI 30 40 50 60
Discharge Capacity US GPM5 14 14 12 9 10210 13.5 13.5 10 7.5 10015 13 13 9.8 7 9820 13 12.5 9 6.5 96
25 12 11 8 6 94
Suction Lift
Depth (feet)
Discharge Pressure - PSIMax Shut OFF
PSI 30 40 50 60
Discharge Capacity US GPM5 40 30 18 12 7410 40 29 16.5 10.5 7215 39.5 28.5 14.5 9 7020 39.5 28.5 12 8.5 68
25 39.5 28.5 11.5 8 66
DIMENSIONS AND WEIGHT
JSW 05
JSWH 07
JSW 07
JSW 10
JSWH 10 JSWQ 15
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN1 DN2 a f h h1 h2 h3 n n1 w s 1~ 3~
JSW 05 JSW 05 1" 1" 4.5 15.2 / 14.9 6.7 5.0 1.3 6.3 6.3 4.9 0.4 0.4 22.1 22.5
JSW 07 JSW 07 1" 1" 4.5 15.8 7.9 5.8 1.4 7.2 7.1 5.6 0.9 0.4 30.3 30.5
JSWH 07 JSWH 07 1" 1" 4.5 15.8 7.9 5.8 1.4 7.2 7.1 5.6 0.9 0.4 30.3 30.5
JSW 10 JSW 10 1" 1" 4.5 15.8 7.9 5.8 1.4 7.2 7.1 5.6 0.9 0.4 33.2 30.5
JSWH 10 JSWH 10 1" 1" 4.5 15.8 7.9 5.8 1.4 7.2 7.1 5.6 0.9 0.4 33.2 30.9
JSWQ 15 JSWQ 15 1 1/4" 1" 4.5 15.8 7.9 5.8 1.4 7.2 7.1 5.6 0.9 0.4 59.0 57.0
f
a
ws
DN2
n1
n
DN
1
h3 h
h1
h2
38
Flow rate up to 21 gpmHead up to 236 ft
Manometric suction lift up to 29 ftLiquid temperature up to + 104°F Environment temperature up to + 104°F
They are recommended for pumping clean water and liquids that arechemically non aggressive to the materials from which the pump is made. JCR SELF-PRIMING PUMPS ARE DESIGNED FOR SUCTION LIFTSAND CAN BE POSITIONED ABOVE THE WATER SOURCE,INCLUDING APPLICATIONS WITH AIR ENTRAINED IN THE WATER.DUE TO THEIR RELIABILITY AND LOW MAINTENANCE, THEY ARERECOMMENDED FOR DOMESTIC USE, INCLUDING WATERDISTRIBUTION (AS PART OF A PRESSURE SET), GARDENIRRIGATION, ETC.The pumps must be installed in enclosed places, or at least protectedagainst inclement weather.
• PUMP BODY: stainless steel AISI 304, with threaded ports.
• BODY BACK-PLATE: stainless steel AISI 304.
• EJECTOR ASSEMBLY: technopolymer (approved for drinking water).
• IMPELLER: technopolymer (for drinking water).
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104
• MECHANICAL SEAL: ceramic - graphite - NBR.
• ELECTRIC MOTOR: the pumps are close-coupled to a carefullymatched PEDROLLO electric motor, quiet running, totally enclosed fancooled (TEFC), suitable for continuous dut..
JCR: single-phase 115 V or 230 V - 60 Hz with capacitor and thermal overload protector.
JCR: three-phase 230/460 V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 44.
⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
JCR “Shallow Well” self-priming jet pumpsstainless steel pump body
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
39
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Suction Lift
Depth (feet)
Discharge Pressure - PSIMax Shut OFF
PSI 30 40 50 60
Discharge Capacity US GPM5 12 8 5 2 7010 11 6.5 4 1.5 6815 10.5 6.5 3.5 1 65.5 20 8.5 5.5 3 0.5 62.5 25 8 5 2.5 61.5
Suction Lift
Depth (feet)
Discharge Pressure - PSIMax Shut OFF
PSI 30 40 50 60
Discharge Capacity US GPM5 21 20 7 2 6510 18.5 11 6.5 1,5 6315 16.2 10 5.3 6120 14.9 8 2.9 5925 7.2 5.5 1.5 57
Suction Lift
Depth (feet)
Discharge Pressure - PSIMax Shut
OFF PSI 30 40 50 60
Discharge Capacity US GPM5 14 13 8.5 6 8010 13 12 8 5 7815 12 11 7 4 7620 10 9 6 3 7425 9 7 5 2 72
Suction Lift
Depth (feet)
Discharge Pressure - PSIMax Shut OFF
PSI 30 40 50 60
Discharge Capacity US GPM5 22 21 15.9 10 7910 22 21 14.5 8.5 7715 21 20 12.6 7.2 7520 20 18.5 10.6 5 7325 20 18 10.3 4 71
Suction Lift
Depth (feet)
Discharge Pressure - PSIMax Shut OFF
PSI 30 40 50 60
Discharge Capacity US GPM5 14 14 12 9 10210 13.5 13.5 10 7.5 10015 13 13 9.8 7 9820 13 12.5 9 6.5 96
25 12 11 8 6 94
JCR 05 JCR 07
JCRH 07 JCR 10
JCRH 10
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN1 DN2 a f h h1 h2 n n1 w s 1~ 3~
JCR 05 JCR 05 1" 1" 3.5 13.9/ 13.6 6.9 4.8 2.0 6.3 4.7 3.7 0.4 15.2 14.3
JCR-JCRH 07 JCR-JCRH 07 1 1/4" 1" 4.6 16.0 8.1 5.7 2.2 7.2 5.3 4.3 0.4 20.7 21.2
JCR-JCRH 10 JCR-JCRH 10 1 1/4" 1" 4.6 16.0 8.1 5.7 2.2 7.2 5.3 4.3 0.4 23.8 22.9
fa
w s
DN2
n1
n
DN
1
h
h1
h2
40
Flow rate up to 16 gpm
Manometric suction lift up to 147 ftLiquid temperature up to + 104°F Environment temperature up to + 104°F
JDW SELF-PRIMING PUMPS ARE DESIGNED FOR LIFTING WATERFROM DEPTHS GREATER THAN 10 ft, INCLUDING CASES WITHENTRAINED AIR. THEY ARE RECOMMENDED FOR DOMESTIC USEINCLUDING WATER DISTRIBUTION (AS PART OF A PRESSURESET), GARDEN IRRIGATION, ETC.The pumps must be installed in enclosed places, or at least protectedagainst inclement weather.
• PUMP BODY: cast iron, with threaded ports.
• EJECTOR BODY: cast iron
• NOZZLE, VENTURI AND DIFFUSER: technopolymer.
• IMPELLER: technopolymer.
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• MECHANICAL SEAL: ceramic - graphite - NBR.
• ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty.JDWm: single-phase 115 V or 230 V - 60 Hz with capacitor and
thermal overload protector.JDW: three-phase 230/460 V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 44.
⇒ Impeller in technopolymer (JD...X - JD...X)⇒ other voltages or frequency 50 Hz
DESCRIPTION JD4 30/20/10 03
SeriesType of nozzle and venturiMotor size
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
JD “JET” self-priming pumps for deep wells
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
41
DIMENSIONS AND WEIGHT
4” “JET” self-priming pumps for 4” deep wells
MODELHP
HS
Feet
FLOW RATE GPM0 0.5 1 1.6 2.1 2.7 3.2 3.7 4.2 4.8 5.3 6.4 6.4
1 PH 3 PH FEETJD430 07 JD430 07
0.7
50174 164 151 138 128 121 112 101 95 88 78 65
JD420 07 JD420 07 131 118 112 105 98 92 89 85 80 75 72 62 59
JD410 07 JD410 07 98 95 92 89 85 84 82 78 75 72 68 65 63
JD430 07 JD430 07 65 102 92 85 82 75 71 66 60 55 52 49 42 41
JD430 07 JD430 07 95 69 66 59 56 52 51 49 45 42 39 37 36 32
JD430 07 JD430 07 115 118 105 89 79 66 56 46 39
HS: SUCTION HEIGHT
MODEL SUCTION/DISCH DIMENSIONS INCHES LBS
1 PH 3 PH DNp DN1 DN2 DN3 DN4 De a a1 a2 f h h1 h2 n n1 w s 1~ 3~
JD4 07 JD4 07 4" 1 1/4" 1" 1" 1" 3.8 2.7 1.8 5.8 13.8 13.8 3.6 7.1 7.1 7.1 0.9 0.4 36.2 34
*Weight includes the Eyector
42
3” JDW self-priming pumps for 3” deep wells
MODELHP
HS
Feet
FLOW RATE GPM
0 0.5 1 1.6 2.1 2.7 3.2 3.7 4.2
1 PH 3 PH FEET
JD3 07 JD3 07 0.70
50 128 115 105 95 89 82 72 66 56
65 108 98 89 75 69 56
95 89 79 72
HS: SUCTION HEIGHT
DIMENSIONS AND WEIGHT
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS *1 PH 3 PH DNp DN1 DN2 DN3 DN4 De a 123 540 242 108 207 206 164 22 10 25.5 1~ 3~
JD3 07 JD3 07 3" 1" 1" 3/4" 1" 2.8 2.7 1.8 5.1 13.8 7.9 3.6 7.1 7.1 5.7 0.9 0.4 34.7 32.5
*Weight includes the Eyector
2” JDW self-priming pumps for 2” deep wells
43
MODELHP
HS
Feet
FLOW RATE GPM0 0.5 1 1.6 2.1 2.7 3.2 3.7 4.2 4.8 5.3
1 PH 3 PH FEET
JD2 07 JD2 07 0.70
50 177 164 151 141 128 118 112 102 92 82 7565 131 115 102 92 82 75 66 59 5282 115 102 92 85 75 66 5695 92 79 69 56
115 75 59 49
HS: SUCTION HEIGHT
DIMENSIONS AND WEIGHT
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS1 PH 3 PH DNp DN1 DN2 DN3 De a a1 a2 f h h1 h2 n n1 w s 1~ 3~
JD2 07 JD2 07 2" 1 1/4" 1" 1" 5.2 1.8 4.8 18.1 7.9 3.6 7.1 7.1 5.7 0.9 0.4 0.7 38.2 36
44
Flow rate up to 52 gpmHead up to 394 ft
Manometric suction lift up to 29 ftLiquid temperature up to + 104°F Environment temperature up to + 104°F
They are recommended for clean water and liquids that are chemicallynon aggressive to the materials from which the pump is made. PLURIJET SELF-PRIMING PUMPS ARE DESIGNED FOR LIFTINGWATER, EVEN IN CASES WITH ENTRAINED AIR. THEIR QUIETRUNNING, RELIABILITY AND LOW POWER CONSUMPTIONMAKES THEM PARTICULARLY SUITABLE FOR DOMESTIC ANDCIVIL USE, INCLUDING PRESSURISATION AND DISTRIBUTION OFWATER, IRRIGATION AND RAINWATER RECOVERY SYSTEMS. The pumps must be installed in enclosed places, or at least protectedagainst inclement weather.
• PUMP BODY: cast iron and stainless steel AISI 304 (cast iron upto 0.7 HP), with threaded ports.
• IMPELLER: technopolymer (approved for drinking water).
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104
• MECHANICAL SEAL: ceramic - graphite - NBR.
• ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty.PLURIJETm: single-phase 115 V or 230 V - 60 Hz with capacitor
and thermal overload protector.PLURIJET: three-phase 230/460 V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 44.
• REGISTERED MODEL
.
⇒ version in stainless steel EN 10088-3 - 1.4401 (AISI 316)⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
PLURIJET
New self-primingpumps, quiet running,reliable, high efficiency,patented.
self-priming multi-stage pumps
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
45
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d H
(fee
t)
Hea
d H
(met
ers)
Flow Rate Q
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN1 DN2 a f h h1 h2 n n1 w s 1~ 3~
PJ20 04 PJ20 04 1" 1" 4.3 13.1 6.8 5.3 1.5 6.2 4.6 0.1 0.4 20.7 19.6
PJ20 05 PJ20 05 1" 1" 5.3 14.4 /14.1 6.8 5.3 1.5 6.2 4.6 0.1 0.4 23.8 22.5
PJ20 10 PJ20 10 1 1/4 1" 2.7 25.0 9.1 6.0 1.8 7.3 5.7 12.0 0.4 56.3 51.9
PJ20 15 PJ20 15 1 1/4 1" 2.7 26.2 9.1 6.0 1.8 7.3 5.7 13.2 0.4 60.7 59.6
MODELHP
FLOW RATE GPM 0 1 2 7 7 10 13 15 18 21
1 PH 3 PH FLOW RATE l/min 0 5 10 30 30 40 50 60 70 80PJ20 04 PJ20 04 0.4
H Feet
125 118 113 105 95 82 66 51 34 16
PJ20 05 PJ20 05 0.5 164 158 153 141 126 110 92 74 54 33
PJ20 10 PJ20 10 1.0 250 250 241 230 215 299 177 154 133 108
PJ20 15 PJ20 15 1.5 306 306 297 283 266 245 220 195 171 141
fa
w s
DN2
n
DN
1
hh
1h
2
f
a w s
DN2
n1
n
DN
1
h
h1
h2
f
PJ20 04 - 05 PJ20 10 - 15
46
Hea
d H
(met
ers)
CURVES AND PERFORMANCE DATA
Hea
d H
(fee
t)
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN1 DN2 a f h h1 h2 n n1 w s 1~ 3~
PJ30 05 PJ30 05 1" 1" 4.3 13.5 / 13.1 6.8 5.3 1.5 6.2 4.6 0.1 0.4 22.5 20.7
PJ30 07 PJ30 07 1" 1" 5.3 14.9 7.5 5.3 2.4 6.2 4.6 0.1 0.4 29.6 27.1
PJ30 10 PJ30 10 1 1/4" 1" 2.7 22.5 9.1 6.0 1.8 7.3 5.7 9.5 0.4 51.9 47.7
PJ30 15 PJ30 15 1 1/4" 1" 2.7 23.7 9.1 6.0 1.8 7.3 5.7 10.7 0.4 57.2 55.2
PJ30 20 PJ30 20 1 1/4" 1" 2.7 25.0 9.1 6.0 1.8 7.3 5.7 12.0 0.4 60.7 59.6
PJ30H 20 1 1/4" 1" 2.7 26.2 9.1 6.0 1.8 7.3 5.7 13.2 0.4 64.0
MODELHP
FLOW RATE GPM 0 1.3 2.6 5.2 7.9 10.6 13 15 18 21 26 31 34
1 PH 3 PH FLOW RATE l/min 0 5 10 20 30 40 50 60 70 80 100 120 130PJ30 05 PJ30 05 0.5
H Feet
118 117 115 110 105 99 92 85 76 66 44 16
PJ30 07 PJ30 07 0.7 151 148 141 138 131 125 117 108 99 87 62 33 16
PJ30 10 PJ30 10 1.0 164 163 161 158 151 148 145 140 133 126 112 89 79
PJ30 15 PJ30 15 1.5 214 214 210 207 204 197 191 184 174 164 141 115 102
PJ30 20 PJ30 20 2.0 266 266 263 260 253 246 240 230 217 207 177 145 128
PJ30H 20 2.0 319 319 315 312 302 296 286 273 260 246 210 171 151
Flow Rate Q
DIMENSIONS AND WEIGHT
fa
w
DN2
n1
n
DN
1
hh
1h
2
a ws
DN2
n1
n
DN
1
h
h1
h2
n
PJ30 05 - 07 PJ30 10 - 15 - 20
47
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(met
ers)
Hea
d HH
(fee
t)
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN1 DN2 a f h h1 h2 n n1 w s 1~ 3~
PJ50 10 PJ50 10 1 1/4" 1" 2.7 22.5 9.1 6.0 1.8 7.3 5.7 9.5 0.4 51.9 47.7
PJ50 15 PJ50 15 1 1/4" 1" 2.7 23.7 9.1 6.0 1.8 7.3 5.7 10.7 0.4 57.2 55.2
PJ50 20 PJ50 20 1 1/4" 1" 2.7 25.0 9.1 6.0 1.8 7.3 5.7 12.0 0.4 60.7 59.6
PJ50H 20 1 1/4" 1" 2.7 26.2 9.1 6.0 1.8 7.3 5.7 13.2 0.4 64.0
MODELHP
FLOW RATE GPM 0 5 10 13 15 21 26 31 37 42 47 52
1 PH 3 PH FLOW RATE l/min 0 20 40 50 60 80 100 120 140 160 180 200PJ50 10 PJ50 10 1
H Feet
148 141 138 135 131 125 115 105 92 76 59 43
PJ50 15 PJ50 15 1.5 191 187 181 177 174 161 148 131 115 99 79 56
PJ50 20 PJ50 20 2 240 233 227 223 217 204 184 168 145 125 99 72
PJ50H 20 2 286 279 269 263 256 240 220 197 174 148 118 85
Flow Rate QQ
a ws
DN2
n1
n
DN
1
h
h1
h2
n
48
Flow rate up to 24 gpmHead up to 180 ft.
Liquid temperature up to + 194°FEnvironment temperature up to + 104°F
They are recommended for pumping clean water without abrasiveparticles and liquids that are chemically non aggressive to the materialsfrom which the pump is made. THE NON-FERROUS CONSTRUCTIONGUARANTEES AGAINST RUST AND OXIDATION. THE COMPACTDESIGN AND HYDRAULIC CHARACTERISTICS SUIT INDUSTRIALAPPLICATIONS INCLUDING COOLING AND CONDITIONINGSYSTEMS. The pumps must be installed in enclosed places, or at least protectedagainst inclement weather.
• PUMP BODY: bronze, with threaded ports.
• MOTOR BRACKET (patent nº 1289150) PK-Bz, PQ-Bz: aluminium with brass front insert.
• BODY BACK-PLATE: CP-Bz: stainless steel AISI 316.
• IMPELLER: PK-Bz, PQ-Bz: brass.CP-Bz: stainless steel AISI 316
• MOTOR SHAFT: stainless steel AISI 316.
• MECHANICAL SEAL: ceramic - graphite - VITON.
• ELECTRIC MOTOR: induction motor, for continuous duty.Single-phase: 115 V or 230 V - 60 Hz with capacitor and thermal
overload protector.Three-phase: 230/460 V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 44.
⇒ special mechanical seal⇒ other voltages or frequency 50 Hz⇒ protection IP 55⇒ for liquids with higher temperatures ⇒ for environments with higher temperatures
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
Bz pumps with bronze body
CONSTRUCTION AND SAFETY STANDARDS
EN 60034-1IEC 34-1CEI 2-3
49
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MODELHP
FLOW RATE GPM 0 1.3 2.6 3.9 5.2 6.6 7.9 9.2 10.5 13.2 15.8
1 PH 3 PH FLOW RATE l/min 0 5 10 15 20 25 30 35 40 50 60PKBZ 03 PKBZ 03 0.33
H Feet131 124 110 95 78 64 49 32 16
PKBZ 05 PKBZ 05 0.5 181 164 149 133 118 101 88 72 55 26
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN1 DN2 a f h h1 h2 h3 i m n n1 w s 1~ 3~
PKBZ 03 PKBZ 03 1" 1" 1.7 9.5 5.9 2.4 2.9 5.4 0.7 3.1 4.7 3.9 2.1 0.2 11.7 11.7
PKBZ 05 PKBZ 05 1" 1" 1.9 10.2/9.8 5.9 2.4 3.1 5.6 0.7 3.1 4.7 3.9 2.1 0.2 17.0 14.1
f
a w ms
DN2i
n1n
DN
1 h3 h
h1
h2
50
Hea
d HH
(met
ers)
CURVES AND PERFORMANCE DATA
Hea
d HH
(fee
t)
Flow Rate QQ
DIMENSIONS AND WEIGHT
MODELHP
FLOW RATE GPM 0 1.3 2.6 3.9 5.2 6.6 7.9 9.2 10.5 13.2 15.8
1 PH 3 PH FLOW RATE l/min 0 5 10 15 20 25 30 35 40 50 60PQBZ 03 PQBZ 03 0.33
H Feet131 124 110 95 78 64 49 32 16
PQBZ 05 PQBZ 05 0.5 181 164 149 133 118 101 88 72 55 26
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN1 DN2 a f h h1 h2 h3 i m n n1 w s 1~ 3~
PQBZ 03 PQBZ 03 1" 1" 1.7 9.5 5.9 2.4 2.9 5.4 0.7 3.1 4.7 3.9 2.1 0.2 11.7 11.7
PQBZ 05 PQBZ 05 1" 1" 1.9 10.2/9.85 5.9 2. 3.1 5.6 0.7 3.1 4.7 3.9 2.1 0. 17 14.1
f
a w ms
DN2i
n1n
DN
1
h3 h
h1
h2
CURVES AND PERFORMANCE DATA
Hea
d HH
(fee
t)
Flow Rate QQ
51
DIMENSIONS AND WEIGHT
Hea
d HH
(met
ers)
MODELHP
FLOW RATE GPM 0 2.6 5.2 7.9 10.5 13.2 15.8 18.5 21 23.8
1 PH 3 PH FLOW RATE l/min 0 10 20 30 40 50 60 70 80 90CPBZ 03 CPBZ 03 0.33
H Feet76 72 69 66 62 59 56 51 46
CPBZ 07 CPBZ 07 0.7 118 112 108 108 105 102 99 95 89 82
MODEL SUCTION /DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN1 DN2 a f h h1 h2 n n1 W s 1~ 3~
CPBZ 03 CPBZ 03 1" 1" 1.7 10.2 8.1 3.2 4.8 6.5 5.3 1.6 0.4 18.8 18.3
CPBZ 07 CPBZ 07 1" 1" 1.7 11.2 9.4 3.6 5.8 7.5 6.3 1.5 0.4 28.3 27.2
fa
w s
DN2
n1
n
DN
1 h
h1
h2
52
Flow rate up to 105 gpmHead up to 48 ft
Depth up to 16 ft (10 ft up to 0.55 Hp)Liquid temperature up to 104°f (+194°f for a maximum period of 3 minutes)Passage of solid bodies up to 4/10”Drainage level:1/2” from the bottom for TOP up to 0.5 Hp1 1/16” from the bottom for TOP 0.7 and 1.0 Hp
THE TTOOPP SERIES IS SUITABLE FOR DRAINING CLEAR WATERWITHOUT ABRASIVE PARTICLES. THE CONSTRUCTIONGUARANTEES SIMPLE AND SAFE OPERATION DUE TO THECOMPLETE COOLING OF THE MOTOR BY THE PUMPED WATERAND THE DOUBLE SEAL DESIGN. THEY ARE RECOMMENDEDFOR EMERGENCY DRAINING OF SMALL FLOODED AREAS(ROOMS, CELLARS, GARAGES), FOR THE DISPOSAL OF WASTEWATER IN THE HOME (DISHWASHER, WASHING MACHINE) ANDFOR EMPTYING DRAINAGE TRAPS.
• DELIVERY BODY: glass filled technopolymer, particularly resistant to impact and corrosion, with threaded port.
• SUCTION GRID: technopolymer.• IMPELLER: open type in technopolymer.• MOTOR SUPPORT: stainless steel AISI 304.• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.• DOUBLE SEAL: mechanical seal ceramic -graphite - NBR, with oil barrier
chamber and inner lip seal to protect the seal in the event of dry running. • MOTOR: submersible asynchronous single-phase for continuous duty.
TOP: single-phase 115 V or 230 V - 60 Hz with capacitor and thermal overload protector built into the winding.
• INSULATION: class F. • PROTECTION: IP 68.• REGISTERED MODEL nº 72765.
STANDARD FEATURES:TTOOPP up to 0.5 Hp (single-phase) Float switch.
Hosetail.Power cable in neoprene “H05 RN-F” length 15 ft
TTOOPP 0.7 and 1 Hp (single-phase) Float switch.• Hosetail.• Coupling with flap valve. Neoprene power cable “H05 RN-F” length 30 feet
⇒ pumps for aggressive liquids TOP - LA⇒ special mechanical seal⇒ 30 ft power cable.
N.B. required for outdoor use to comply with standard EN 60335-2-41⇒ versions without float switch⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
TOP
Already recognized for theirinnovative design and safetyfeatures, TOP pumps combinea stainless steel internal motorhousing with technologicallyadvanced materials to give anexceptionally robustconstruction.
SUMP pumpsfor clear water
53
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Flow Rate QQ
Hea
d HH
(met
ers)
MODELHP
FLOW RATEGPM 0 5 10 15 21 26 31 37 42 47 52 58 63 68 74 79 84 89 95 100 105
1 PH FLOW RATE l/min 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400TOP 025 0.25
H Feet
22 19 18 14 11 8 6 3
TOP 03 0.33 29 26 24 21 19 18 14 13 9 8 5 3
TOP 05 0.5 34 32 29 28 26 24 21 19 18 15 13 11 8 6
TOP 07 0.7 41 39 37 35 32 30 28 26 23 21 19 17 15 13 10 8 6
TOP 10 1.0 47 45 44 41 39 37 35 33 31 29 27 25 23 20 19 17 14 12 10 8 6
MODEL DISCH DIMENSIONES INCHESLBS
1 PH DN a h h1 d e p minTOP 025 1"
5.9
9.1 8.5
14
ADJUSTABLE
13.7 13.7
9.1
TOP 031 1/4"
10.1 9.3 11.1
TOP 05 11.3 10.5 14.1
TOP 071 1/2" 8.0 13.1 12.2 0.8 17.7 17.7
21.7
TOP 10 23.9
a minimum
e
p m
inim
um
hh1
d
Typical installation
DN
54
Flow rate up to 58 gpmHead up to 29 ft
Depth up to 10 ftLiquid temperature up to 104°f (194°f for a maximum period of 3 minutes)Drainage level 1/8” from the bottom
THE TOP-FLOOR SERIES IS SUITABLE FOR DRAINING CLEARWATER WITHOUT ABRASIVE PARTICLES. THEIR ABILITY TODRAIN WATER DOWN TO 1/8” FROM THE FLOOR MAKES THEMIDEAL FOR EMERGENCY DOMESTIC USE FOR SMALL FLOODEDAREAS AND IN ALL THOSE APPLICATIONS WHERE MAXIMUMDRAINAGE IS REQUIRED.
• DELIVERY BODY: glass filled technopolymer, particularly resistantto impact and corrosion, with threaded port.
• SUCTION GRID: technopolymer.
• IMPELLER: open type in technopolymer.
• MOTOR SUPPORT: stainless steel AISI 304.
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• DOUBLE SEAL: mechanical seal ceramic - graphite - NBR,with oil barrierchamber and inner lip seal to protect the seal in the event of dry running.
• MOTOR: submersible asynchronous single-phase for continuous duty.TOP-FLOOR: single-phase 115 V or 230 V - 60 Hz with capacitor and
thermal overload protector.
• INSULATION: class F. • PROTECTION: IP 68.
• REGISTERED MODEL nº 72765
STANDARD FEATURES:
TTOOPP--FFLLOOOORR Neoprene power cable “H05 RN-F” length 15 ftHosetail.
⇒ versions with external float switch ⇒ special mechanical seal⇒ 30 ft power cable.
N.B. required for outdoor use to comply with standard EN 60335-2-41⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
TOPFLOOR
The particularconstructive design ofthe TOP FLOOR pumpallows draining down toa level of 1/8” above thefloor.
SUMP pumpsfor clear water
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
55
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d H
(fee
t)
Flow Rate Q
Hea
d H
(met
ers)
MODELHP
FLOW RATE GPM 0 5 10 15 21 26 31 37 42 47 52 58
1 PH FLOW RATE l/min 0 20 40 60 80 100 120 140 160 180 200 220TOPF 025 0.25
H Feet22 19 18 14 11 8 6 3
TOPF 03 0.3 29 26 24 21 19 18 14 13 9 8 5 3
a
Dra
inin
g D
ow
n t
o1/
8”
hh1
Typical installation
DN
MODEL DISCH DIMESIONS [INCHES] Minimum SuctionLBS
1 PH DN a h h1 Level [INCHES]
TOPF 025 1" 5.9 9.1 8.50.1
8.6
TOPF 03 1 1/4" 5.9 10.1 9.3 10.8
56
Flow rate up to 47 gpmHead up to 23 ft
Depth up to 10 ftLiquid temperature up to 104°f (194° f for a maximum period of 3 minutes)Passage of solid bodies up to Ø 3/4”Drainage level 1” from the bottom
THE TTOOPP--VVOORRTTEEXX PUMP IS SUITABLE FOR DRAINING DIRTYWATER THAT IS CHEMICALLY NON AGGRESSIVE. THECONSTRUCTION GUARANTEES SIMPLE AND SAFE OPERATIONDUE TO THE COMPLETE COOLING OF THE MOTOR BY THEPUMPED WATER AND THE DOUBLE SEAL DESIGN.IT IS RECOMMENDED FOR DOMESTIC USE, FOR THE CLEARINGOF DIRTY WATER, FOR EMPTYING TANKS, DOMESTIC DRAINSAND COLLECTION TRAPS, EVEN WITH SUSPENDED SOLIDBODIES WITH DIMENSIONS UP TO Ø 3/4”.
• DELIVERY BODY: glass filled technopolymer, particularly resistantto impact and corrosion, with threaded port.
• SUCTION GRID: technopolymer.
• IMPELLER: technopolymer.
• MOTOR SUPPORT: stainless steel AISI 304.
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• DOUBLE SEAL: mechanical seal ceramic - graphite - NBR, with oil barrierchamber and inner lip seal to protect the seal in the event of dry running.
• MOTOR: submersible asynchronous single-phase for continuous duty.TOP-VORTEX: single-phase 115 V or 230 V - 60 Hz with capacitor and
thermal overload protector.
• INSULATION: class F. • PROTECTION: IP 68.
• REGISTERED MODEL nº 72765
STANDARD FEATURES:
TTOOPP--VVOORRTTEEXX Float switch.Hosetail.Neoprene power cable “H05 RN-F” length 15 ft.
⇒ special mechanical seal⇒ 30 ft power cable.
N.B. required for outdoor use to comply with standard EN 60335-2-41⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
TOPVORTEX
Thanks to the provenVORTEX system, thissubmersible pumpallows the clearing ofdirty water containingsuspended solid bodieswithout any risk ofclogging the impeller.
VORTEX SUMP pumpfor dirty water
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
57
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Flow Rate QQ
Hea
d HH
(met
ers)
MODELHP
FLOW RATE GPM 0 5 10 15 21 26 31 37 42 47
1 PH FLOW RATE l/min 0 20 40 60 80 100 120 140 160 180
TOPV 03 0.33 H Feet 23 21 19 17 15 13 11 9 8 4
MODEL DISCH DIMENSIONS INCHESLBS
1 PH DN a h h1 d e p min
TOPV 03 1 1/4" 6.0 11.3 10.6 1.0 adjustable 13.7 13.7 11.0
aminimum
ep m
inim
um
hh1
d
Typical installation
DN
58
Flow rate up to 26 gpmHead up to 137 ft
Submersion depth up to 32 ft Liquid temperature up to + 104°fEmptying level up to 1 1/16” from the bottom
THEY ARE RECOMMENDED FOR PUMPING CLEAN WATER.THEIR HIGH EFFICIENCY AND RELIABILITY MAKES THEMSUITABLE FOR SUPPLYING DOMESTIC WATER FROM TANKS,RESERVOIRS OR RELATIVELY DEEP WELLS, DRAWINGRAINWATER FROM CISTERNS, WATERING BY HAND OR FEEDING.
• DELIVERY BODY AND SUCTION GRID: glass filled technopolymer, particularly resistant to impact and corrosion, withthreaded port.
• IMPELLERS and DIFFUSERS: technopolymer.
• DIFFUSER CONTAINER: stainless steel AISI 304.
• MOTOR SUPPORT: stainless steel AISI 304.
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• DOUBLE SEAL: mechanical seal ceramic -silicon carbide-NBR, withoil barrier chamber and inner lip seal to protect the seal in the eventof dry running.
• MOTOR: asynchronous, for continuous duty.TOP M: single-phase 115 V or 230 V - 60 Hz with capacitor and
thermal overload protector.
• INSULATION: class F. • PROTECTION: IP 68.
• REGISTERED MODEL n° 72765.
STANDARD FEATURES:
TTOOPP--MMUULLTTII Float switchNeoprene power cable “H05 RN-F” length 30 ftHosetail.Coupling with non-return valve.
⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
TOP MULTImulti-stage submersible pumpsfor clear water
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
59
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d H
(fee
t)
Flow Rate Q
Hea
d H
(met
ers)
a
minimum
e
p m
inim
umhh1
d
Typical portable application
DN
MODELHP
FLOW RATE GPM 0 2 5 7 10 13 14 18 21 23 26
1 PH FLOW RATE l/min 0 10 20 30 40 50 55 70 80 90 100TOPM 03 0.33
H Feet
118 108 100 87 71 48 16
TOPM 05 0.5 98 95 92 89 85 79 72 62 49 34 16
TOPMH 05 0.5 138 125 115 102 82 57 26
MODEL DISCHARGEStages
DIMENSIONS INCHESLBS
1 PH DN a h h1 d min e p min
TOPM 03
1 1/4"
6
6.9014.96 13.58
1.18 13.7 13.7
18.6
TOPM 05 5 17.9
TOPMH 05 7 15.75 13.58 19.7
60
Flow rate up to 79 gpmHead up to 75 ft
Depth up to 30 ftLiquid temperature up to 120°f Liquid temperature up to 104°f for intermittent duty.Liquid temperature up to 194°f for intermittent duty maximum 3 minutes.Passage of solid bodies up to Ø 3/8”Drainage level:1/2” from the bottom for RX up to 0.33 hp1” from the bottom for RX 0.50 Hp, 0.75 Hp, and 1.0 Hp
RX PUMPS ARE SUITABLE FOR DRAINING CLEAR WATERWITHOUT ABRASIVE PARTICLES. THE CONSTRUCTION GUARANTEES SIMPLE AND SAFEOPERATION DUE TO THE COMPLETE COOLING OF THE MOTORBY THE PUMPED WATER, AND THE DOUBLE SEAL DESIGN. THEYARE RECOMMENDED FOR FIXED INSTALLATIONS, EMERGENCYDRAINING OF SMALL FLOODED AREAS (BASEMENT ROOMS,CELLARS, GARAGES), FOR DISPOSAL OF DIRTY WATER USED INTHE HOME BY WASHING MACHINES AND DISHWASHERS ANDFOR DRAINING COLLECTION TRAPS.
• DELIVERY BODY: stainless steel AISI 304, with threaded port• SUCTION GRID: stainless steel AISI 304.• IMPELLER: stainless steel AISI 304.• MOTOR SUPPORT: stainless steel AISI 304.• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.• DOUBLE SEAL: mechanical seal ceramic - graphite - NBR,with oil barrier
chamber and inner lip seal to protect the seal in the event of dry running.• MOTOR: submersible asynchronous single-phase for continuous duty.
RXm: single-phase 115 V or 230 V - 60 Hz with capacitor and thermal overload protector.
RX: three-phase 230V - 60 Hz.• INSULATION: class F. • PROTECTION: IP 68.
• REGISTERED MODEL.
STANDARD FEATURES:RRXX (single-phase) float switch.
Neoprene power cable “H05 RN-F” length 15 feet
RRXX (three-phase) Neoprene power cable “H05 RN-F”length 15 feet
⇒ special mechanical seal⇒ 30 feet power cable.
N.B. required for outdoor use to comply with standard EN 60335-2-41⇒ control box for three-phase electropumps 1 Hp⇒ single-phase versions without float switch⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
RX
Robust high-quality submersiblepumps in stainless steel, fordrainage of clear water. Recommended for fixedinstallations or for drainingdomestic water or rainwater,and for emptying tanks orreservoirs.
SUMP pumpsfor clear water
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
61
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Flow Rate QQ
Hea
d HH
(met
ers)
MODELHP
FLOW RATE GPM 0 5 10 15 21 26 31 37 42 47 52 58 63 68 74 79
1 PH 3 PH FLOW RATE l/min 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300RX 025 0.25
H Feet
25 21 19 16 14 11 9 7
RX 030 RX 030 0.33 33 31 29 26 24 21 19 16 14 11 9 7
RX 05 RX 05 0.5 56 52 49 45 42 38 34 31 28 24 21 17 13 10
RX 07 RX 07 0.7 66 62 59 55 52 48 44 41 38 34 31 27 24 20 16
RX 10 RX 10 1.0 75 72 69 66 62 58 54 51 48 44 41 37 33 30 26 23
MODEL DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN a h h1 d e p min 1~ 3~
RX 025 1 1/4" 5.7 10.0 9.7 0.6
Adjustable
13.8 13.810
RX 030 RX030 13 12
RX 05 RX 051 1/2" 8.4 13.9 13.2 1.1 19.7 19.7
27 24
RX 07 RX 07 29 26
RX 10 RX 10 31 28
a minimum
ep m
inim
um
hh1
d
Typical single-phase installation
DN
62
Flow rate up to 118 gpmHead up to 47ft
Depth up to 10 mLiquid temperature up to 122°f Liquid temperature up to 104°f for intermittent duty.Liquid temperature up to 194°f for intermittent duty maximum 3 minutes.Passage of solid bodies:up to 3/4” for 0.33 hp - up to 1.5” from 0.5 Hp to 1.0 HpDrainage level from the bottom:1” for 0.33 Hp - 1.5” from 0.5 Hp to 1.0 Hp
RRXX--VVOORRTTEEXX PUMPS ARE SUITABLE FOR DRAINING DIRTYWATER. THE CONSTRUCTION GUARANTEES SIMPLE AND SAFEOPERATION, DUE TO THE COMPLETE COOLING OF THE MOTORBY THE PUMPED WATER. THEY ARE RECOMMENDED FORDOMESTIC USE, FOR DRAINING DIRTY WATER CONTAININGSUSPENDED SOLIDS.
• DELIVERY BODY: stainless steel AISI 304, with threaded port• SUCTION GRID: stainless steel AISI 304.• IMPELLER: stainless steel AISI 304.• MOTOR SUPPORT: stainless steel AISI 304.• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.• DOUBLE SEAL: mechanical seal silicon carbide - NBR, with oil barrier
chamber and inner lip seal to protect the seal in the event of dry running.• MOTOR: submersible asynchronous single-phase for continuous duty.
RXm: single-phase 115V or 230 V - 60 Hz with capacitor and thermal overload protector.
RX: three-phase 230V - 60 Hz.• INSULATION: class F. • PROTECTION: IP 68.• REGISTERED MODEL.
STANDARD FEATURES:RRXXmm (single-phase) float switch.
Neoprene power cable “H05 RN-F”length 15 feet
RRXX (three-phase) Neoprene power cable “H05 RN-F”length 15 feet.
⇒ special mechanical seal⇒ 30 feet power cable.
N.B. required for outdoor use to comply with standard EN 60335-2-41⇒ control box for three-phase pumps 1Hp⇒ single-phase versions without float switch⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
RXVORTEX
Robust high-qualityVORTEX submersiblepumps in stainlesssteel. The provenVORTEX system allowsthe clearing of dirtywater containingsuspended solids.
SUMP pumpfor dirty water
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
63
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MODELHP
FLOW RATE GPM 0 5 10 15 21 26 31 37 42 47 52 66 79 86 92 105 119
1 PH 3 PH FLOW RATE l/min 0 20 40 60 80 100 120 140 160 180 200 250 300 325 350 400 450RXV 025 0.25
H Feet
23 21 20 18 16 14 12 10 8 7
RXV 030 RXV 030 0.33 30 28 26 24 22 21 19 17 15 13 11 7
RXV 05 RXV 05 0.5 36 34 33 31 29 27 25 23 22 20 18 13 9 7
RXV 07 RXV 07 0.7 49 48 46 44 42 40 38 36 34 32 30 26 21 18 16 11 7
MODEL DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN a h h1 d e p min 1~ 3~
RXV 025 1 1/4" 5.8 10.0 9.7 0.7
Adjustable
13.8 13.8 13 13
RXV 030 RXV 0300.5 0.5
27 25
RXV 05 RXV 051 1/2" 8.5 15.9 15.2 1.6
30 27
RXV 07 RXV 07 32 29
a minimum
ep m
inim
um
hh1
d
Typical single-phase installation
DN
64
Flow rate up to 105 gpmHead up to 88 ft
Depth up to 15 ftLiquid temperature up to 104°f Passage of suspended solid bodies up to 3/8”Drainage level 1/2” from the bottomFor continuous duty: minimum immersion 8.5” from pump base
DESIGNED FOR DRAINING CLEAR OR SLIGHTLY DIRTY WATERWITH SMALL SOLIDS, THEY ARE RECOMMENDED FORDOMESTIC, CIVIL AND PROFESSIONAL USE, FOR DRAININGFLOODED AREAS SUCH AS CELLARS AND GARAGES OR FOREMPTYING SWIMMING POOLS OR TANKS AND FOR DISPOSINGOF NON-SEWAGE WASTE WATER. THESE PUMPS AREOUTSTANDING IN THEIR RELIABILITY IN FIXED INSTALLATIONSWITH AUTOMATIC OPERATION.
• DELIVERY BODY: cast iron, with threaded port ISO 228/1.• MOTOR CASING: stainless steel AISI 304.• SUCTION GRID: stainless steel AISI 304.• IMPELLER: open type, in glass filled technopolymer • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.• DOUBLE SEAL: mechanical seal silicon carbide - NBR, with oil barrier
chamber and inner lip seal to protect the seal in the event of dry running.• MOTOR: submersible asynchronous for continuous duty.
D: single-phase 115 V or 230 V - 60 Hz with capacitor and thermal overload protector.
D: three-phase 230V - 60 Hz.• INSULATION: class F. • PROTECTION: IP 68.
STANDARD FEATURES:DD (single-phase) Float switch.
Neoprene power cable “H07 RN-F”length 15 ft
DD (three-phase) Neoprene power cable “H07 RN-F”length 15 ft
⇒ 30 ft power cable. N.B. required for outdoor use to comply with standard EN 60335-2-41
⇒ control box for three-phase pumps 1.0 Hp⇒ single-phase pumps without float switch⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
D
DRAINAGE submersiblepumps for professionaluse, particularly reliablewith generous motorspecification and hard-faced mechanical seal.
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
DRAINAGE submersible pumpsfor clear or slightly dirty water
65
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MODELHP
FLOW RATE GPM 0 7 13 20 26 33 40 46 53 60 66 73 79 86 93 106
1 PH 3 PH FLOW RATE l/min 0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 400D 04 0.4
H Feet
30 28 26 25 22 20 17 13 9 3
D 05 0.5 39 38 36 34 32 30 27 24 20 16 11 7
D 07 D 07 0.7 49 48 46 43 41 39 36 33 30 26 22 18 11 7
D 10 D 10 1 64 62 61 59 57 54 52 49 46 43 39 34 30 26 23 13
DH 05 0.5 56 54 49 44 39 35 30 25 16
DH 07 DH 07 0.7 69 66 62 57 52 49 44 39 33
DH 10 DH 10 1 89 85 82 77 72 69 64 59 52 48 43 38 33
MODEL DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN a b c h h1 d e p min 1~ 3~D 04
1 1/2"
4.1 3.1 5.3 12.6 2.6
0.5 Adjustable 19.7 19.7
23
D 05 26
D 07 D 07 29 26
D 10 D 10 4.3 3.5 5.5 13.3 3.1 34 31
DH 054.1 3.1 5.3 12.6 2.6
27
DH 07 DH 07 29 26
DH 10 DH 10 4.3 3.5 5.5 13.3 3.1 34 31
a
minimum
e
p m
inim
um
h
h1
db
Typical single-phase installation
c
DN
66
Flow rate up to 132 gpmHead up to 49 ft
Depth up to 15 ftLiquid temperature up to 104°f Passage of suspended solid bodies up to 2”For continuous duty: minimum immersion 11” from pump base
THEY ARE RECOMMENDED FOR DOMESTIC, CIVIL ANDINDUSTRIAL USE, IN APPLICATIONS WHERE THE WATERCONTAINS SUSPENDED SOLIDS WITH DIMENSIONS UP TO Ø 2 plg.THEIR USE IS RECOMMENDED FOR DRYING FLOODED AREASSUCH AS CELLARS, UNDERGROUND CAR PARKS, CAR WASHINGAREAS, OR DOMESTIC DRAINS AND FOR EMPTYING CESSPITSOR SEWAGE DISPOSAL. THESE PUMPS ARE OUTSTANDING INTHEIR RELIABILITY IN FIXED INSTALLATIONS WITH AUTOMATICOPERATION.
• DELIVERY BODY: cast iron, with threaded port• MOTOR CASING: stainless steel AISI 304.• Base: stainless steel AISI 304.• IMPELLER: stainless steel AISI 304.• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.• DOUBLE SEAL: mechanical seal silicon carbide - NBR, with oil barrier
chamber and inner lip seal to protect the seal in the event of dry running.• MOTOR: submersible asynchronous for continuous duty.
VX: single-phase 115 V or 230V - 60 Hz with capacitor and thermal overload protector.
VX: three-phase 230V - 60 Hz.• INSULATION: class F. • PROTECTION: IP 68.
STANDARD FEATURES:
VVXX (single-phase) Float switch.Neoprene power cable “H07 RN-F”length 15 ft.
VVXX (three-phase) Neoprene power cable “H07 RN-F”length 15 ft.
⇒ 30 ft power cable. N.B. required for outdoor use to comply to standard EN 60335-2-41
⇒ control panel for three-phase pumps 1 Hp⇒ single-phase pumps without float switch⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
VX
VORTEX submersible pumps forprofessional use, particularlyreliable with generous motorspecification and hard-facedmechanical seal. The provenVORTEX system allows theclearing of dirty watercontaining suspended solids.
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
VORTEX submersible pumpsfor sewage water
67
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MODELHP
FLOW RATE GPM 0 13 26 40 53 66 79 93 106 119 132
1 PH 3 PH FLOW RATE l/min 0 50 100 150 200 250 300 350 400 450 500
VXH 05 0.5
H Feet
28 25 21 17 12 7
VXH 07 VXH 07 0.7 33 31 28 24 19 13 7
VXH 10 VXH 10 1 49 46 43 39 34 30 25 20 13 7
VX 05 0.5 20 18 16 14 12 9 7 3
VX 07 VX 07 0.7 25 23 21 19 16 13 10 8 5
VX 10 VX 10 1 36 34 33 31 30 27 25 22 20 16 13
MODEL DISCH Passage of DIMENSIONS INCHES LBS1 PH 3 PH DN Solid bodies a b c h h1 d e p min 1~ 3~
VXH 051 1/2" 1 1/2"
4.1 3.4 5.4 15.0 4.8 1.6
Adjustable 19.7 19.7
27.4
VXH 07 VXH 07 29.8 26.7
VXH 10 VXH 10 4.33.6 5.6 15.7 5.2
2.234.7 32.3
VX 052" 2"
3.5 5.9 16.1 6.029.6
VX 07 VX 074.7 2.6
30.7 26.7
VX 10 VX 10 3.8 6.4 16.9 6.2 35.6 33.2
a
minimum
e
p m
inim
umh
h1
d
b
Typical single-phase installation
c
DN
68
Flow rate up to 105gpmHead up to 49 ft
Depth up to 15 ftLiquid temperature up to 104°f Passage of suspended solid bodies up to 2”For continuous duty: minimum immersion 11” from pump base.
THEY ARE RECOMMENDED FOR DRAINING WASTE WATER INTHE DOMESTIC, CIVIL AND INDUSTRIAL SECTORS, INAPPLICATIONS WHERE THE WATER CONTAINS SUSPENDEDSOLIDS WITH DIMENSIONS UP TO Ø 2 plg. THEIR USE ISRECOMMENDED FOR DRYING FLOODED AREAS SUCH ASCELLARS, UNDERGROUND CAR PARKS, CAR WASHING AREASAND FOR EMPTYING CESSPITS or SEWAGE DISPOSAL. THESE PUMPS ARE OUTSTANDING IN THEIR RELIABILITY INFIXED INSTALLATIONS WITH AUTOMATIC OPERATION.
• DELIVERY BODY: stainless steel AISI 304, with threaded port • MOTOR CASING AND BASE: stainless steel AISI 304.• IMPELLER: stainless steel AISI 304.• MOTOR SHAFT: stainless steel AISI 316.• DOUBLE SEAL: mechanical seal silicon carbide - NBR - stainless
steel AISI 316, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running.
• MOTOR: submersible asynchronous for continuous duty.VXS: single-phase 115V or 230V - 60 Hz with capacitor and `
thermal overload protector .VXS: three-phase 230V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 68.
STANDARD FEATURES:
VVXXSS (single-phase) Flow switch.Neoprene power cable “H07 RN-F”length 15 ft
VVXXSS (three-phase) Neoprene power cable “H07 RN-F”length 15 ft
⇒ 30 ft power cable. N.B. required for outdoor use to comply with standard EN 60335-2-41
⇒ single-phase pumps without float switch⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
VXS
VORTEX stainless steelsubmersible pumps for professionaluse, particularly reliable withgenerous motor specification andhard-faced mechanical seal. The proven VORTEX system allowsthe clearing of dirty watercontaining suspended solids.
VORTEX submersible pumpsfor sewage water
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
69
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MODELHP
FLOW RATE GPM 0 13 26 39 52 66 79 92 105
1 PH 3 PH FLOW RATE l/min 0 50 100 150 200 250 300 350 400VXSH 05 VXSH 05 0.5
H Feet
28 25 21 17 12 7
VXSH 07 VXSH 07 0.7 33 31 28 24 19 13 7
VXS 05 VXS 05 0.5 20 18 16 14 12 9 7 3
VXS 07 VXS 07 0.7 25 23 21 19 16 13 10 8 5
MODEL DISCH Passage of DIMENSIONS INCHES LBS1 PH 3 PH DN Solid bodies a b h h1 d e p min 1~ 3~
VXSH 05 VXSH 051 1/2" 1 1/2" 4.3
6.5
15.0 3.4 1.6
Adjustable 19.7 19.7
21.4
VXSH 07 VXSH 07 21.2 20.6
VXS 05 VXS 052" 2" 4.6 16.1 4.3 2.2
28.3
VXS 07 VXS 07 23.6 21.4
a
minimum
e
p m
inim
umh
h1
db
Typical single-phase installation
DN
70
Flow rate up to 132 gpmHead up to 49 ft
Depth up to 30 ftLiquid temperature up to 104°f Passage of solid bodies 1 1/4” Passage of solid bodies 1 3/4” For continuous duty: minimum immersion 11” from pump base
THE PUMPS IN THE VXC SERIES ARE MADE OF EXCEPTIONALLYROBUST HEAVY-GAUGE CAST IRON, RESISTANT TO ABRASIONAND ARE EQUIPED WITH A VORTEX TYPE IMPELLER. THEY ARERECOMMENDED FOR DRAINING WASTE WATER CONTAININGSUSPENDED SOLID BODIES, SEWAGE AND WATER MIXED WITHMUD.
• PUMP BODY: cast iron, with threaded port• MOTOR CASING AND BASE: cast iron. • IMPELLER: stainless steel AISI 304.• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.• DOUBLE SEAL: mechanical seal silicon carbide - NBR, with oil barrier
chamber and inner lip seal to protect the seal in the event of dry running.• MOTOR: submersible asynchronous for continuous duty.
VXCH-M: single-phase 115V or 230 V - 60 Hz with thermal overload protector.VXCH-M: three-phase 230V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 68.
STANDARD FEATURES:
VVXXCCHH--MM (single-phase) Float switch.Neoprene power cable “H07 RN-F”length 30 ftControl box with capacitor (Protection IP 64).
VVXXCCHH--MM (three-phase) Neoprene power cable “H07 RN-F”length 30 ft
⇒⇒ control box for three-phase pumps 1 Hp⇒⇒ single-phase pumps without float switch⇒⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
VXCH-M
VORTEX submersible pumpsmade of cast iron,particularly robust andreliable, ideal for fixedinstallations. The provenVORTEX system allows theclearing of dirty watercontaining suspended solids.
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
VORTEX submersible pumpsfor sewage water
71
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MODELHP
FLOW RATE GPM 0 13 26 39 52 66 79 92 105 119 132
1 PH 3 PH FLOW RATE /min 0 50 100 150 200 250 300 350 400 450 500
VXCH 05 0.5
H Feet
32 28 25 20 14 8
VXCH 07 VXCH 07 0.7 38 36 32 27 22 15 8
VXCH 10 VXCH 10 1 57 53 49 45 40 34 28 23 15 8
VXCM 05 0.5 23 21 19 17 14 11 8 4
VXCM 07 VXCM 07 0.7 28 26 25 22 19 15 12 9 6
VXCM 10 VXCM 10 1 42 40 38 36 34 31 28 26 23 19 15
MODEL DISCH Passage of DIMENSIONS INCHES LBS1 PH 3 PH DN Solid bodies a b c h h1 m n o d e p min 1~ 3~
VXCH 051 1/2" 1 1/2"
4.1 3.5 5.4 13.8 4.8
3.2 7.9 2.6
1.6
Adjustable 19.7 19.7
37.6
VXCH 07 VXCH 07 41.3 37.8
VXCH 10 VXCH 104.3
3.6 5.6 14.6 5.2 46.2 43.8
VXCM 052" 2 "
3.5 5.9 14.8 5.82.2
39.8
VXCM 07 VXCM 07 43.5 39.8
VXCM 10 VXCM 10 4.7 3.8 6.4 15.6 6.0 48.4 46.0
Typical single-phase installation
a
minimumc
o
e
p m
inim
um
h
h1
d
m
n
b
SINGLE-PHASE CONTROL BOX
D N
72
Flow rate up to 317 gpmHead up to 52 ft
Depth up to 30 ftLiquid temperature up to 104°f Passage of solid bodies max up to 3” For continuous duty: minimum immersion 16” from pump base
VVXXCC SERIES PUMPS ARE MADE OF EXCEPTIONALLY ROBUSTHEAVY-GAUGE CAST IRON, RESISTANT TO ABRASION ANDLONG-LASTING, AND HAVE A VORTEX TYPE IMPELLER. THEYARE SUITABLE FOR SEWAGE, WASTE WATER AND SLUDGE,INCLUDING WATER CONTAINING SOLIDS OR MUD. THEY AREIDEAL FOR SEWAGE INSTALLATION, TUNNELS AND OTHEREXCAVATIONS, UNDERGROUND CAR PARKS AND SIMILARAPPLICATIONS.
• PUMP BODY, MOTOR CASING: cast iron.• IMPELLER: cast iron.• BASE: stainless steel AISI 304.• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4057.• DOUBLE SEAL: mechanical seal silicon carbide - widia -NBR, with oil
barrier chamber and inner lip seal to protect the seal in the event of dry running.• MOTOR: submersible asynchronous, 2 pole, for continuous duty.
VXC-L: single-phase 230V - 60 Hz Models up to 1.5 Hp have built in thermal protection 2 Hp single-phase versions have a thermal protector provided in the winding for connection to the control box.
VXC-L: three-phase 230V - 60 Hz. -Thermal protectors are provided in the winding for connectionto the external control panel
• INSULATION: class F. • PROTECTION: IP 68.
STANDARD FEATURES:VVXXCC--LL (single-phase) Float switch.
30 ft “H07 RN-F” submersible power cable1 Hp to 1.5 Hp models are supplied with control box with capacitorand manual reset motor protector.2 Hp models are supplied with control box typeQES 300 MONO.
VVXXCC--LL (three-phase) 30 ft “H07 RN-F” neoprene power cable
⇒⇒ control box for three-phase pumps⇒⇒ dual voltage: 230/400 V - 60 Hz⇒⇒ single-phase versions without float switch⇒⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
VXC-L
VORTEX submersible pumps incast iron, particularly robust andreliable, intended for continuousheavy duty use in fixedinstallations, in building servicesand industry. Recommended forsewage and waste water of alltypes with solid impurities.
VORTEX submersible pumpsfor sewage water
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
73
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MODELHP
FLOW RATE GPM 0 26 52 79 92 105 132 158 185 211 224 238 264 291 317
1 PH 3 PH FLOW RATE l/min 0 100 200 300 350 400 500 600 700 800 850 900 1000 1100 1200VXCL 10 VXCL 10 1
H Feet
37 34 31 26 23 21 14 6
VXCL 15 VXCL 15 1.5 42 39 36 31 29 26 21 14 6
VXCL 20 VXCL 20 2 52 49 45 42 40 37 32 26 19 10 6
VXC 10 VXC 10 1 21 0 18 16 15 14 12 9 7 4 3
VXC 15 VXC 15 1.5 27 0 24 21 20 19 17 14 11 9 7 6 3
VXC 20 VXC 20 2 36 0 31 29 28 26 24 21 19 16 15 13 10 8 4
MODEL DISCH Passage of DIMENSIONS INCHES LBS1 PH 3 PH DN Solid bodies a b c h h1 m n o d e p min 1~ 3~
VXCL 10 VXCL 102 1/2" 2 1/2" 6.4 5.3 8.3
19.37.4
3.1 7.8 3.3
2.9
Adjustable 31.4 31.4
73.5 68.5
VXCL 15 VXCL 15 76.9 73.5
VXCL 20 VXCL 20 19.7/19.3 89.9 76.9
VXC 10 VXC 103" 3" 7.1 5.9 9.4
20.89.0 3.3
85.9 80.8
VXC 15 VXC 15 90.1 85.9
VXC 20 VXC 20 19.7/19.3 103.8 90.8
a
minimumc
o
e
p m
inim
um
h
h1
d
m
n
b
SINGLE-PHASE CONTROL BOX
D N
Typical single-phase installation
74
Flow rate up to 211gpmHead up to 49 ft
Depth up to 15 ftLiquid temperature up to 104°f Passage of suspended solid bodies up to 2”For continuous duty: minimum immersion 11” from pump base
MMCC SUBMERSIBLE PUMPS ARE RECOMMENDED FOR DRAININGDIRTY WATER AND SEWAGE IN THE DOMESTIC AND CIVILSECTORS. THEY ARE EQUIPPED WITH A “DOUBLE-CHANNEL”STAINLESS STEEL IMPELLER WHICH ALLOWS THE PUMPING OFLIQUIDS CONTAINING SUSPENDED SOLID BODIES WITHDIMENSIONS UP TO Ø 2 plg AND SHORT FIBRES. THEY AREIDEAL FOR PUMPING DRAINAGE WATER, SEWAGE OR WASTEWATER FOR A SINGLE DWELLING, AND FOR CLEARING SUFACEOR NUISANCE WATER, EVEN IF MUDDY. THESE PUMPS AREOUTSTANDING IN THEIR RELIABILITY IN FIXED INSTALLATIONSWITH AUTOMATIC OPERATION.
• DELIVERY BODY: cast iron, with threaded port • MOTOR CASING: stainless steel AISI 304.• Base: stainless steel AISI 304.• IMPELLER: double-channel in stainless steel AISI 304.• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.• DOUBLE SEAL: mechanical seal silicon carbide - NBR, with oil barrier
chamber and inner lip seal to protect the seal in the event of dry running.• MOTOR: submersible asynchronous for continuous duty.
MC: single-phase 115V or 230V - 60 Hz with capacitor and thermal overload protector.
MC: three-phase 230V - 60 Hz.• INSULATION: class F. • PROTECTION: IP 68.
STANDARD FEATURES:
MMCC (single-phase) Float switch.Neoprene power cable “H07 RN-F”length 15 ft
MMCC (three-phase) Neoprene power cable “H07 RN-F”length 15 ft
⇒⇒ 30 ft power cable. N.B. required for outdoor use to comply with standard EN 60335-2-41
⇒⇒ control box for three-phase pumps 1 Hp⇒⇒ single-phase pumps without float switch⇒⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
MC
DOUBLE-CHANNELsubmersible pumps forprofessional use.Particularly efficientand reliable, withgenerous motorspecification and hard-faced mechanical seal.
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
DOUBLE-CHANNEL submersible pumpsfor sewage water
75
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MODELHP
FLOW RATE GPM 0 13 26 39 52 66 79 92 105 119 132 158 185 211
1 PH 3 PH FLOW RATE l/min 0 50 100 150 200 250 300 350 400 450 500 600 700 800MC 07 MC 07 0.7
H Feet39 35 32 29 26 22 19 16 13 10 7
MC10 MC 10 1 49 46 43 40 38 34 32 29 26 23 20 15 9 3
MODEL DISCH Passage of DIMENSIONS INCHES LBS1 PH 3 PH DN Solid bodies a b c h h1 d e p min 1~ 3~
MC 07 MC 072" 2"
43.3 35.4 59.1 161.4 60.2 21.7Adjustable 19.7 19.7
31.6 29.4
MC10 MC 10 47.2 14.6 64.2 169.3 62.2 25.6 36.5 31.6
a
minimum
ep m
inim
um
h
h1
db
Typical single-phase installation
c
DN
76
Flow rate up to 210 gpmHead up to 49 ft
Depth up to 15 ftLiquid temperature up to 104°f Passage of suspended solid bodies up to 2”For continuous duty: minimum immersion 11” from pump base
MMCC--II SUBMERSIBLE PUMPS ARE RECOMMENDED FORDRAINING DIRTY WATER AND SEWAGE IN THE DOMESTIC ANDCIVIL SECTORS. THEY ARE EQUIPPED WITH A “DOUBLE-CHANNEL” STAINLESS STEEL IMPELLER WHICH ALLOWS THEPUMPING OF LIQUIDS CONTAINING SUSPENDED SOLID BODIESWITH DIMENSIONS UP TO 2 plg. AND SHORT FIBRES. THEY AREIDEAL FOR PUMPING DRAINAGE WATER, SEWAGE OR WASTEWATER FOR A SINGLE DWELLING, AND FOR CLEARINGSURFACE OR NUISANCE WATER, EVEN IF MUDDY. THESE PUMPSARE OUTSTANDING IN THEIR RELIABILITY IN FIXEDINSTALLATIONS WITH AUTOMATIC OPERATION.
• DELIVERY BODY: stainless steel AISI 304, with threaded port• MOTOR CASING AND BASE: stainless steel AISI 304.• IMPELLER: double-channel, in stainless steel AISI 304.• MOTOR SHAFT: stainless steel AISI 316.• DOUBLE SEAL: mechanical seal silicon carbide - NBR - stainless steel
AISI 316, with oil barrier chamber and inner lip seal to protect the seal inthe event of dry running.
• MOTOR: submersible asynchronous for continuous duty. MCS: single-phase 115V or 230V - 60 Hz with capacitor and
thermal overload protector.MCS: three-phase 230V - 60 Hz.
• INSULATCION: class F. • PROTECTION: IP 68.
STANDARD FEATURES:
MMCCSS (single-phase) Float switch.Neoprene power cable “H07 RN-F”length 15 ft
MMCCSS (three-phase) Neoprene power cable “H07 RN-F”length 15 ft
⇒⇒ 30 ft power cable. N.B. required for outdoor use to comply with standard EN 60335-2-41
⇒⇒ control box for three-phase pumps 1 Hp⇒⇒ single-phase pumps without float switch⇒⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
MCS
DOUBLE-CHANNELstainless steel submersiblepumps for professionaluse. Particularly efficientand reliable, with generousmotor specification andhard-faced mechanicalseal.
DOUBLE-CHANNEL submersible pumpsfor sewage water
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
77
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MODELHP
FLOW RATE GPM 0 13 26 39 52 66 79 92 105 119 132 158 185 211
1 PH 3 PH FLOW RATE l/min 0 50 100 150 200 250 300 350 400 450 500 600 700 800MCS 07 MCS 07 0.7
H Feet39 35 32 29 26 22 19 16 13 10 7
MCS 10 1 49 46 43 40 38 34 32 29 26 23 20 15 9 3
MODEL DISCH Passage of DIMENSIONS INCHES LBS
1 PH 3 PH DN Solid bodies a b h h1 d e p min 1~ 3~
MCS 07 MCS 072" 2" 4.6 6.5 16.1 4.3 2.2 Adjustable 19.6 19.68 28
22
MCS 10 28
a
minimum
e
p m
inim
umh
h1
db
Typical single-phase installation
DN
78
Flow rate up to 211 gpmHead up to 49 ft
Depth up to 30 ftLiquid temperature up to 104°fPassage of suspended solid bodies up to 1 3/4”For continuous duty: minimum immersion 11” from pump base
THE PUMPS IN THE MMCCMM SERIES ARE MADE OF EXCEPTIONALLYROBUST HEAVY-GAUGE CAST IRON, RESISTANT TO ABRASIONAND LONG-LASTING. THEY ARE EQUIPPED WITH A DOUBLE-CHANNEL IMPELLER WHICH ALLOWS THE DRAINAGE OFLIQUIDS CONTAINING SUSPENDED SOLID BODIES WITHDIMENSIONS UP TO Ø 1 3/4” AND SHORT FIBRES. THEY AREIDEAL FOR PUMPING DRAINAGE WATER AND SEWAGE, WASTEWATER INCLUDING WATER MIXED WITH MUD, GROUNDWATERAND SURFACE WATER IN APPLICATIONS SUCH AS:CONDOMINIUMS, MULTI-STOREY AND UNDERGROUND CARPARKS, WASHING AREAS AND INDUSTRY.
• PUMP BODY: cast iron, with threaded port
• MOTOR CASING AND BASE: cast iron.
• IMPELLER: double-channel, in stainless steel AISI 304.
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• DOUBLE SEAL: mechanical seal silicon carbide - NBR, with oil barrierchamber and inner lip seal to protect the seal in the event of dry running.
• MOTOR: submersible asynchronous for continuous duty. MCM: single-phase 115V or 230V - 60 Hz with thermal overload protector.MCM: three-phase 230V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 68.
STANDARD FEATURES:
MMCCMM (single-phase) Float switch.Neoprene power cable “H07 RN-F”length 30 ftControl box with condenser.
MMCCMM (three-phase) Neoprene power cable “H07 RN-F”length 30 ft
⇒ control box for three-phase pumps 1 Hp⇒ single-phase pumps without float switch⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
MCM
DOUBLE-CHANNEL castiron submersible pumpsfor professional use.Particularly efficientand reliable, withgenerous motorspecification and hard-faced mechanical seal.
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
DOUBLE-CHANNEL submersible pumpsfor sewage water
79
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MODELHP
FLOW RATE GPM 0 13 26 39 52 66 79 92 105 119 132 158 185 211
1 PH 3 PH FLOW RATE l/min 0 50 100 150 200 250 300 350 400 450 500 600 700 800
MCM 07 MCM 07 0.7H Feet
39 35 32 29 26 22 19 16 13 10 7
MCM 10 MCM 10 1 49 46 43 40 38 34 32 29 26 23 20 15 9 3
MODEL DISCH Passage of DIMENSIONS INCHES LBS
1 PH 3 PH DN Solid bodies a b c h h1 m n o d e p min 1~ 3~MCM 07 MCM 07
2" 1 3/4"4 3.5 5.9 14.8 5.8
3.1 7.8 2.5 2.1 Adjustable 19.6 19.643.9 40.4
MCM 10 MCM 10 4.7 3.8 6.4 15.6 6.0 48.8 46.4
Typical single-phase installation
a
minimumc
o
e
p m
inim
um
h
h1
d
m
n
b
SINGLE-PHASE CONTROL BOX
D N
80
Flow rate up to 422 gpmHead up to 78 ft
Depth up to 30 ftLiquid temperature up to 104°fPassage of solid bodies max up to 3” For continuous duty: minimum immersion 16” from pump base
MMCC--LL SERIES PUMPS ARE MADE OF EXCEPTIONALLY ROBUSTHEAVY GAUGE CAST IRON, ABRASION RESISTANT AND LONG-LASTING, WITH A SINGLE-CHANNEL IMPELLER WHICH CANHANDLE LIQUIDS WITH SUSPENDED SOLIDS AND SHORTFIBRES. THEY ARE iDEAL FOR SEWAGE, WASTE AND GROUNDWATER, EVEN WITH SOLIDS OR MUD, AND ARE THEREFORERECOMMENDED FOR BUILDING OR INDUSTRIAL EFFLUENT ANDDRAINAGE OF LARGE AREAS SUCH AS CAR PARKS.
• PUMP BODY, MOTOR CASING: cast iron.• IMPELLER: single-channel, in cast iron.• BASE: stainless steel AISI 304.• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4057.• DOUBLE SEAL: mechanical seal silicon carbide - widia - NBR,
with oil barrier chamber and inner lip seal to protect the seal in the event of dry running.
• MOTOR: submersible asynchronous, 2 pole, for continuous duty.MC-L: single-phase 230V - 60 Hz
Models up to 1.5 Hp have built in thermal protection2.0 Hp single-phase versions have a thermal protector provided in the winding for connection to the control box.
MC-L: three-phase 230V - 60 Hz. - Thermal protectors are provided in the winding for connection to the external control panel
• INSULATION: class F. • PROTECTION: IP 68.
STANDARD FEATURES:MMCC--LL (single-phase) Float switch.
30 ft “H07 RN-F” submersible power cable.1.0 to 1.5 Hp models are supplied with control box with capacitorand manual reset motor protector.2.2 Hp models are supplied with control box type QES 300 MONO.
MMCC--LL (three-phase) 30 ft “H07 RN-F” neoprene power cable
⇒ control box for three-phase pumps⇒ dual voltage: 230/440V -60 Hz⇒ single-phase versions without float switch⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
MC-L
SINGLE-CHANNEL submersible pumpshighly efficient and particularlyrobust and reliable. Ideal for fixedinstallations or for continuous heavyduty use, recommended for sewageand waste water with solid impuritiesin building services or industrialapplications.
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
SINGLE-CHANNEL submersible pumpsfor sewage water
81
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MODELHP
FLOW RATE GPM 0 13 26 52 79 105 132 158 185 211 238 264 291 317 370 423
1 PH 3 PH FLOW RATE l/min 0 50 100 200 300 400 500 600 700 800 900 1000 1100 1200 1400 1600MCL 10 MCL 10 1
H Feet
52 49 46 41 34 28 23 16 10 3
MCL 15 MCL 15 1.5 59 56 52 46 41 34 30 23 16 10 3
MCL 20 MCL 20 2 79 75 72 66 59 52 46 39 33 26 20 13 7
MC 20 MC 20 2 43 41 39 38 36 33 31 29 27 25 22 20 17 16 10 7
MODEL DISCH Passage of DIMENSIONS INCHES LBS1 PH 3 PH DN Solid bodies a b c h h1 m n o d e p min 1~ 3~
MCL 10 MCL 102 1/2" 2" 6 5 8
19.37
3 8 33
Adjustable 31 31
75.1 70.3
MCL 15 MCL 15 78.9 75.1
MCL 20 MCL 20 19.7/19.3 92.2 79.1
MC 20 MC 20 3" 3" 28.2 33.8 21.5 19.7/19.3 9.5 3.34 106.1 93.0
a
minimumc
o
e
p m
inim
um
h
h1
d
m
n
b
SINGLE-PHASE CONTROL BOX
D N
Typical single-phase installation
82
Flow rate up to 13 gpmHead up to 223 ft
Submersion depth up to 131 ftLiquid temperature up to + 104°F
It is recommended for pumping clean water without abrasive particlesand liquids that are chemically non aggressive to the materials fromwhich the pump is made. COMPACT AND ECONOMICAL, IT ISRECOMMENDED FOR RESIDENTIAL APPLICATIONS INCLUDINGWATER SUPPLIES AND IRRIGATION.
• DELIVERY BODY: stainless steel AISI 304.
• IMPELLER HOUSING WITH PATENTED DOUBLE ANTI-SEIZE INSERTS.
• IMPELLER: brass, type with radial peripheral vanes.
• MOTOR JACKET: stainless steel AISI 304.
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• MOTOR: asynchronous, dry rewindable stator, for continuous duty4SK: single-phase 230 V - 60 Hz.
• INSULATION: class F. • PROTEZIONE: IP 68.
• MECHANICAL SEAL: ceramic - graphite - NBR.
STANDARD FEATURES:
44SSKKmm Thermal overload protector.Internal capacitorFlat type 30 ft power cable.
⇒ 60 t power cable⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
4SK
Stainless steel submersible pump withperipheral impeller and anti-seize system.Standard version includes 30 feet power cableand integral capacitor for ease of installation.
4" submersible pump with peripheral impeller
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
83
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MMOODDEELL HHPP PPSSIIDDEEPPTTHH TTOO WWAATTEERR IINN FFEEEETT//RRAATTIINNGGSS IINN GGPPMM
2200 4400 6600 8800 110000 112200 114400
4SK 070.70
0 11 10.5 9 8 6 5
20 10 9 7 6.2 5 3
30 8 7 6 5
40 7 5 4
Shut -off PSI 117 108 100 91 82 44 36
MODEL DISCH DIMENSIONS INCHES LBS
1 PH DN1 Ø h 1~
4SK 07 1" 3.9 19.6 29
The 4SK pump may be installed inboreholes with a diameter not lessthan 4”. The electropump islowered into the borehole bymeans of the delivery pipe to sucha depth as to guarantee itscomplete immersion (min. 19”and at least one meter from thebottom). Its good practice tosecure the pump by means of astainless steel or nylon cable,connected to the anchoring pointson the delivery body.
Typical InstallationDN
h
Connection point for safety cable
Ø
84
Flow rate up to 23 gpmHead up to 348 ft
Liquid temperature up to 104°fSubmersion depth up to 65 ft
THEIR HIGH EFFICIENCY AND RELIABILITY MAKE THEMSUITABLE FOR PUMPING CLEAN WATER IN DOMESTIC, CIVILAND AGRICULTURAL APPLICATIONS, FOR DISTRIBUTING WATERIN COMBINATION WITH PRESSURE SETS, FOR IRRIGATINGGARDENS, BOOSTING PRESSURE, ETC.
• OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304 • IMPELLERS AND DIFFUSERS: technopolymer.• DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings.• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.• DOUBLE SEAL: mechanical seal silicon carbide-NBR, with oil barrier
chamber and inner lip seal to protect the seal in the event of dry running.• SCREWS AND FILTER: stainless steel AISI 304.• MOTOR: asynchronous for continuous duty.
SUMO 18G: single-phase 230V - 60 Hz with thermal overload protector built into windings below 1.5 Hp. The 2 Hpmotor has an external overload protector (with manual reset) incorporated into the control box.
SUMO 18G: three-phase 230V - 60 Hz.• INSULATION: class F. • PROTECTION: IP 68.
STANDARD FEATURES:SSUUMMOO 1188 GG (single-phase) control box with capacitor
70 ft power cable type “H07 RN-F” with removable connector
SSUUMMOO 1188 GG (three-phase) 70 ft power cable type“H07 RN-F” with removable connector.
⇒ economy version 30 ft power cable and capacitor, (without control box)⇒ single-phase pumps with external float switch (SUMO 18G...- GE)⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
SUMO 18G
The best combination ofperformance, reliabilityand quiet running,robust and easy to use.
multi-stage submersible pumps
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
85
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d H
(fee
t)
Flow Rate Q
Hea
d H
(met
ers)
c
b
SINGLE-PHASE CONTROL BOX
a
DN
h
DN
h
Attachment point for safety cable
Single-phase with control box
Attachment point for safety cable
Single-phase with float switch
Ø Ø
MODEL DISCHARGE DIMENSIONS INCHES LBS1 PH 3 PH DN N° STAGES Ø h (1~) h (3~) a b c 1~ 3~
SUMO18G 05 -
1"3
5.3
15.115.1
3.1 7.8 2.5
26.3
SUMO18G 07 SUMO18G 07 17.0 28.7 25.4
SUMO18G 10 SUMO18G 10 418.0
18.0 36.5 33.2
- SUMO18G 15 518.9
37.6
SUMO18G 15 -1 1/4"
4
6.0
20.1 52.2
SUMO18G 20 SUMO18G 20 5 21.3 21.3 54.1 50.4
SUMO18GH 20 SUMO18GH 20 5 23.1 21.3 64.5 51.9
MODELHP
FLOW RATE GPM 0 2 5 7 10 11 13 14 15 17 18 19 21 22 23
1 PH 3 PH FLOW RATE l/min 0 10 20 30 40 45 50 55 60 65 70 75 80 85 90
SUMO18G 05 SUMO18G 05 0.5
H Feet
125 120 115 108 102 97 92 87 82 76 69 62 56 49 39
SUMO18G 07 SUMO18G 07 0.7 177 174 171 164 158 153 148 141 138 130 123 115 108 99 92
SUMO18G 10 SUMO18G 10 1.0 223 218 210 204 192 186 181 172 164 158 151 141 135 123 115
SUMO18G 15 SUMO18G 15 1.5 283 276 269 256 243 237 230 220 210 200 191 177 164 151 138
SUMO18G 20 SUMO18G 20 2.0 329 319 306 289 273 263 253 240 230 217 207 194 179 164 151
SUMO18GH 20 SUMO18GH 20 2.0 348 340 329 315 299 289 279 269 260 243 233 214 204 184 164
86
Flow rate up to 34 gpmHead up to 296 ft
Liquid temperature up to 104°fSubmersion depth up to 65 ft
THEIR HIGH EFFICIENCY AND RELIABILITY MAKE THEMSUITABLE FOR PUMPING CLEAN WATER IN COMMERCIAL, CIVILAND AGRICULTURAL APPLICATIONS, FOR DISTRIBUTING WATERIN COMBINATION WITH PRESSURE SETS, FOR IRRIGATINGGARDENS, BOOSTING PRESSURE, ETC.
• OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304 • IMPELLERS AND DIFFUSERS: technopolymer.• DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings.• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.• DOUBLE SEAL: mechanical seal silicon carbide-NBR, with oil barrier
chamber and inner lip seal to protect the seal in the event of dry running.• SCREWS AND FILTER: stainless steel AISI 304.• MOTOR: asynchronous for continuous duty.
SUMO 25G: single-phase 230V - 60 Hz with thermal overload protector built into windings below 1.5 Hp. The 2 Hp motor has an external overload protector (with manual reset) incorporated into the control box.
SUMO 25G: three-phase 230V - 60 Hz.• INSULATION: class F. • PROTECTION: IP 68.
STANDARD FEATURES:
SSUUMMOO 2255GG (single-phase) Control box with capacitor70 ft power cable type “H07 RN-F” with removableconnector and Schuko plug.
SSUUMMOO 2255GG (three-phase) 70 ft power cable type “H07 RN-F” with removable connector.
⇒ economy version 30 ft power cable and capacitor, (without control box)⇒ single-phase pumps with external float switch (SUMO 25G...- GE)⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
SUMO 25G
The perfect combinationof performance, reliabilityand quiet running, robustand easy to use.
multi-stage submersible pumps
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
87
CURVES AND PERFORMANCE DATA
DIMENSIONS AND WEIGHT
Hea
d HH
(fee
t)
Flow Rate QQ
Hea
d HH
(met
ers)
MODELHP
FLOW RATE GPM 0 2 5 7 10 13 15 18 21 23 26 29 31 34
1 PH 3 PH FLOW RATE l/min 0 10 20 30 40 50 60 70 80 90 100 110 120 130SUMO25G 05 SUMO25G 05 0.5
H Feet
105 102 99 94 89 82 76 69 59 49 41 30 20 10
SUMO25G 07 SUMO25G 07 0.7 145 143 141 138 133 128 122 115 105 95 85 76 62 49
SUMO25G 10 SUMO25G 10 1.0 187 186 184 181 177 171 161 151 141 128 118 105 89 72
SUMO25G 15 SUMO25G 15 1.5 223 220 217 210 204 195 187 176 164 151 135 122 105 89
SUMO25G 20 SUMO25G 20 2.0 263 260 253 246 240 233 223 214 204 191 177 161 145 125
SUMO25GH 20 SUMO25GH 20 2.0 296 292 289 283 276 269 263 253 246 237 223 210 195 177
MODEL DISCHARGE DIMENSIONS INCHES LBS1 PH 3 PH DN N° STAGES Ø h (1~) h (3~) a b c 1~ 3~
SUMO25G 05 -
1"3
5.3
15.115.1
3.1 7.8 2.5
26.3
SUMO25G 07 SUMO25G 07 17.0 28.7 25.4
SUMO25G 10 SUMO25G 10 418.0
18.0 36.5 33.2
- SUMO25G 15 518.9
37.6
SUMO25G 15 -1 1/4"
4
6.3
20.1 52.2
SUMO25G 20 SUMO25G 20 5 21.3 21.3 54.1 50.4
SUMO25GH 20 SUMO25GH 20 4 21.9 20.1 62.5 49.9
c
b
SINGLE-PHASE CONTROL BOX
a
DN
h
DN
h
Attachment point for safety cable
Single-phase with control box
Attachment point for safety cable
Single-phase with float switch
Ø Ø
88
Flow rate up to 40 gpmHead up to 442 ft
Liquid temperature up to +86°FSubmersion depth up to 131 feet
THEY ARE RECOMMENDED FOR PUMPING CLEAN WATER DUETO THEIR HIGH EFFICIENCY AND RELIABILITY, THEY ARERECOMMENDED FOR DOMESTIC WATER SUPPLIES AS PART OFA PRESSURE SET, OR FOR IRRIGATION.
• DELIVERY BODY: stainless steel AISI 304 with threaded port.• CASE: stainless steel AISI 304.• IMPELLERS AND DIFFUSERS: technopolymer.• DIFFUSER HOUSING: stainless steel AISI 304.• PUMP SHAFT: stainless steel AISI 304.• PUMP BEARINGS: housing in special technopolymer with stainless
steel AISI 316 shaft bushes, chrome oxide coated to resist sand.• DRIVE COUPLING: stainless steel AISI 316L.• SCREWS AND CABLE COVER: stainless steel AISI 304.• MOTOR SHAFT: stainless steel AISI 316
(EN 10088-3 - 1.4104 up to 0.7 HP).• MOTOR: submersible for continuous duty (dry rewindable).
4BLOCK: single-phase 230 V - 60 Hz.4BLOCK: three-phase 230 V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 68.• DOUBLE SEAL: mechanical seal ceramic - graphite - NBR with oil barrier
chamber and inner lip seal to protect the seal in the event of dry running.
STANDARD FEATURES:
4BLOCK (single-phase) Motor thermal protection built into the winding. Internal capacitor.65 ft flat power cable.
4BLOCK (three-phase) 65 ft flat power cable.
⇒ 100 ft power cable⇒ other voltages or frequency 50 Hz
OPTIONS ON REQUEST
CONSTRUCTION CHARACTERISTICS
GUARANTEE 2 YEARS subject to our general terms of sale.
INSTALLATION AND USE
LIMITS OF USE
RANGE OF PERFORMANCE
4BLOCK
4” monoblock submersible pumps designed asa more inexpensive alternative to traditionalborehole pumps without loss of performanceand reliability. Supplied with integral capacitorand 65 ft power cable for ease of installation.
4" monoblock submersible pumps
CONSTRUCTION AND SAFETY STANDARDS
EN 60 335-1IEC 335-1CEI 61-150
EN 60034-1IEC 34-1CEI 2-3
89
CURVES AND PERFORMANCE DATA
Hea
d H
(fee
t)
Hea
d H
(met
ers)
Flow Rate Q
90
Hea
d HH
(met
ers)
CURVES AND PERFORMANCE DATA
Hea
d HH
(fee
t)
Flow Rate QQ
MODEL HP PSIDEPTH TO WATER IN FEET/RATINGS IN GPM
20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 340 380 420 460
4BLOCK13G07 0.70
0 18 17 16 15 14 12 11 9 720 17 16 15 14 12 11 10 7 530 17 16 15 14 12 11 10 8 440 17 16 15 14 12 11 10 8 450 16 15 14 12 10 9 6 260 15 14 12 11 9 6 2
Shut -off PSI 117 108 100 91 82 74 65 56 48 39 30 22 13
4BLOCK13G10 1
0 12 18 17 16 16 15 14 13 12 10 9 3.2
20 18 17 16 15 14 13 12 11 10 8 6 2
30 18 17 16 15 14 13 12 11 10 8 6 2
40 18 17 16 15 14 13 12 11 10 8 6 2
50 17 16 15 14 14 13 12 10 9 7 360 17 16 15 14 13 11 11 9 7 3
Shut -off PSI 145 136 128 119 110 102 93 84 76 67 58 50 41 32 24 9
4BLOCK13G15 1.5
0 18 18 17 16 16 15 14 14 12 10 8 420 18 18 17 17 16 15 15 14 13 13 12 10 7 330 18 18 17 17 16 15 15 14 13 13 12 11 9 6 240 18 18 17 16 16 16 15 14 13 13 12 11 10 7 250 18 18 17 16 16 15 15 14 13 12 11 10 9 8 460 18 18 17 16 16 15 14 14 13 13 11 10 9 8 5
Shut -off PSI 199 190 182 173 165 156 147 139 130 121 113 104 95 87 78 61 43 26 9
91
CURVES AND PERFORMANCE DATA
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MODEL HP PSIDEPTH TO WATER IN FEET/RATINGS IN GPM
20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 340 380 420 460 500
4BLOCK25G 07 0.75
0 32 30 26 23 18 14 6
20 31 28 24 21 15 10
30 28 24 21 15 10
40 24 21 16 9
50 18 14 6
60 13 5
Shut-off PSI 71 63 54 45 37 28 19
4BLOCK25G 10 1
0 32 29 26 22 18 14 8
20 27 24 20 15 10 4
30 27 23 20 15 10 5
40 27 23 20 15 11 4
50 22 18 14 8
60 18 14 8
Shut-off PSI 84 76 67 58 50 41 32 24 15
4BLOCK25G 15 1.5
0 31 30 28 25 23 20 17 14 9 4
20 32 30 29 26 24 22 19 15 12
30 32 31 28 27 24 22 19 15 12 7
40 32 31 29 27 24 22 19 15 12 7
50 30 28 25 23 20 17 14 9 4
60 28 25 23 20 17 14 10 4
Shut-off PSI 126 117 108 100 91 82 74 65 56 48 39 30 22
4BLOCK25G 20 2
0 32 31 29 28 26 24 22 21 18 14 6
20 29 28 27 25 23 22 20 17 14 12 4
30 30 28 27 25 24 21 20 17 14 12
40 29 28 27 25 23 21 20 17 14 11
50 32 31 29 27 26 24 22 21 19 14 6
60 30 29 27 26 25 22 21 19 13 6
Shut-off PSI 165 156 147 139 130 121 113 104 95 87 78 69 61 52 43 26
92
CURVES AND PERFORMANCE DATA
Hea
d HH
(fee
t)
Hea
d HH
(met
ers)
Flow Rate QQ
MODEL HP PSIDEPTH TO WATER IN FEET/RATINGS IN GPM
20 40 60 80 100 120 140 160 180 200 220 240
4BLOCK33G 07 0.75
0 47 40 31 16
20 43 35 23 10
30 34 23 9
40 24 10
50
60
Shut-off PSI 50 41 32 24 15
4BLOCK33G 10 1
0 45 40 34 24
20 48 43 37 29 15
30 42 38 29 16
40 37 28 16
50 25 6
60
Shut-off PSI 61 52 43 35 26 17 9
4BLOCK33G 15 1.5
0 48 44 40 34 27 17
20 46 41 36 30 21 16
30 46 40 37 29 22 17
40 41 36 31 22 16
50 34 26 17
60 27 18
Shut-off PSI 76 67 58 50 41 32 24 17 9
4BLOCK33G 20 2
0 46 43 39 35 31 25 17
20 41 37 33 28 22 11
30 42 36 33 27 21 12
40 44 41 36 32 29 22 11
50 43 39 35 31 26 18
60 28 24 32 26 19
Shut-off PSI 104 95 87 78 69 61 52 43 35 26 17 9
93
MODEL DISCH DIMENSIONS INCHES LBS1 PH 3 PH DN No Stages Ø h 1 PH 3 PH
4BLOCK13G 07 4BLOCK13G 07
1 1/4"
9
3.92
693/668 23 20
4BLOCK13G 10 4BLOCK13G 10 11 774/749 26 23
4BLOCK13G 15 4BLOCK13G 15 15 987/927 33 28
4BLOCK25G 07 4BLOCK25G 07 6 663/638 22 19
4BLOCK25G 10 4BLOCK25G 10 7 732/707 25 23
4BLOCK25G 15 4BLOCK25G 15 10 901/841 32 26
4BLOCK25G 20 13 */1014 33
4BLOCK33G 07 4BLOCK33G 07 4 629/604 21 19
4BLOCK33G 10 4BLOCK33G 10 5 714/689 25 23
4BLOCK33G 15 4BLOCK33G 15 6 864/804 31 25
4BLOCK33G 20 8 */1008 34
DIMENSIONS AND WEIGHTTypical Installation
STATIC LEVEL
DYNAMIC LEVEL
min 1 meter
DN
h
Connection point for safety cable
Ø