Switchgear, power supply units and electronic energy meters for installation in buildings and use in control technology Switching on the future.
Popular Tags:
114

Click here to load reader

Transcript
Page 1: Catalogo_Eltako_2009_ing

Products and prices 2009

Switchgear, power supply unitsand electronic energy metersfor installation in buildingsand use in control technology

Switching on the future.

Page 2: Catalogo_Eltako_2009_ing

Pictograms

The performance of our switchgear has become so complex that we have devised pictograms to depicttechnical features of particular importance.

WARNING!Only a trained electrician may install our switchgear, power supply units and energy meters, otherwise there is a risk of fi re or elec-tric shock. For this reason, direct sales to end-users, e.g. through a DIY store, are not permitted.

Special models and non-standard control voltages are only supplied ex works. Any return is excluded.

Subject to change! The product descriptions on the internet are valid only for newly manufactured devices at that time.Older devices might differ from them. Therefore, only the enclosed operation instructions are binding.

REACH Directive 1907/2006/EC: Unless otherwise known, no Eltako contains any substance included on the candidate list.

Minimized standby loss of electronic devices supports international efforts to reduce energy consumption. 98% of the switchgear and power supply units produced by ELTAKO have a standby loss of less than 0.6 watt.

No standby loss: this has always been a feature of electromechanical switchgear. Now some of our electronic switchgear devices have this capability too.

Bistable switching relays help electronic switchgear to reduce heating and current consumption. This prolongs lifetime and reduces or avoids standby loss. After installation the short automatic synchronization in the Off position is carried out, partly at initial operation.

The universal control voltage 8 to 253V, AC 50-60Hz and 10 to 230V DC, covers the commonly used control voltage range with one device only. We use the international abbreviation UC (universal current).

Impulse switches for central control offer important basic functions, even if they are not used for central control. In order to reduce the type variety ELTAKO offers them partially only completely equipped with additional control inputs central on/off.

Glow lamps for illumination of push-buttons in parallel to push-button contacts can make life difficult for switchgear. A glow lamp current up to 150mA is permitted for particular device, in particular for staircase time switches.

Zero passage switching of the mains voltage sinusoidal wave prolongs contact lifetime. This provides very high switching capacities and the shallow current flow curve protects the connected consumers. This prolongs in particular the lifetime of energy saving lamps ESL.

Universal dimmer for R, L and C loads. Only universal dimmers with the marking R+L, R+C or R, L, C recognize automatically the connected load and adjust their dimmer function accordingly. Other dimmers have to be replaced when luminaires with different kind of loads will be used later on.

Only dimmer switches with an additional ESL marking are optimized for dimmable energy saving lamps. We recommend "Dimmerable" by .

II

Page 3: Catalogo_Eltako_2009_ing

Contents

III

A

K

Z

J

I

G

F

E

D

C

B

H

L

Electronic impulse switchesalso with release delay, for central control and with multifunction

Universal dimmer switches; also capacity enhancer, 1-10V controllerfor central control and with multifunction

Electronic switching relays, control relays and coupling relaysalso with multifunction

Staircase time switches and off-delay timersalso with multifunction

Time relays and multifunction time relaysdigital and analogue, settable

Calibrated electronic single-phase energy meters and three-phase energy meters; energy meters Economy Line with MID approval

Current relay, mains monitoring relays, current-limiting relays and mains disconnection relay

Shading systems and roller shutter control with sensors, sensor relays, impulse group switches and motor isolating relay

Wide-range switching power supply unitswith low standby loss and high efficiency

Electromechanical impulse switches also impulse multi circuit switches and impulse group switches

Electromechanical switching relays, control relays and installation contactorswith low coil power loss and 100% time on

Installation accessories

ON/OFF switches, momentary-contact switches, group switches and indicator lights

Page 4: Catalogo_Eltako_2009_ing

IV

Key to type identificationKey to abbreviations

ES 12Z – 110 – 8...230V UC

Key to type identification

Key to abbreviation

Series

SubgroupM = multifunctionNP = NP seriesZ = central controlDX = Duplex technology

Number of NO contactsNumber of NC contactsNumber of CO contacts

This contact description is droppedif the device is available in onecontact assignment only.

Control voltage

V = AC voltage 50HzV DC = DC voltage8..230V UC = alternating voltage 8 to 253V AC, 50-60Hz or only UC and direct voltage 10 to 230V DC

Key to abbreviations

Meaning Group

A ON/OFF switch H + L

AR Current relay G

DCM DC motor relay H

DSZ Electronic three-phase energy meter F

DX Duplex technology A + C + E

EDZ Electronic three-phase energy meter with display F

EGS Impulse group switches H

ER Switching relay, control relay and coupling relay C

ES Electronic impulse switch A

ESR Electronic impulse switch with integrated relay function A

ETR Isolating relay C

EUD Universal dimmer switch B

EVA Energy consumption indicator F

EWZ Electronic single-phase energy meter with display F

EZ Single function time relay E

FR Mains disconnection relay G

G Group switch L

GBA Housing for operating instructions Z

K Indicator light L

KM Auxiliary contact J

KR Coupling relay C

LDW Light-twilight-wind sensor relay H

Meaning Group

LS Light sensor H

LUD Capacity enhancer for universal dimmer switches B

MS Multi sensor H

MSR Multi sensor relay H

MTR Motor isolating relay H

MFZ Multifunction time relay E

NLZ Off delay timer D

NR Mains monitoring relay G

P3K Phase annunciator Z

R Electromechanical switching relay K

S Electromechanical impulse switch J

SBR Current-limiting relay G

ST Socket outlet L + Z

SUD 1-10 V controller for universal dimmer switches B

T Momentary-contact switch H + L

TLZ Staircase time switch D

WNT Wide-range switching power supply units I

WS Wind sensor H

WSZ Electronic single-phase energy meter F

XR Installation contactor 25 A K

XS Electromechanical impulse switch 25 A J

ZT Central control momentary-contact switch H + L

For all items, Declarations of Conformity are available and state that a given item conforms toLow Voltage Directive 2006/95/EG and/or EMC Directive 2004/108/EC.

Marking on both the devices and the packing material. All items produced after 2007 conform to EU Directive 2002/95 EC (RoHS)

Page 5: Catalogo_Eltako_2009_ing

Selection table electronic impulse switches A 0Impulse switch ES12DX A1 Impulse switch ES12-200 A 2Impulse switch ES12-110 A3 Impulse switch with integrated relay function ESR12NP A 4Multifunction impulse switch with integrated relay function ESR12M A 5Impulse switch with potential free contacts ES12Z, also for central control A 64-fold impulse switch with integrated relay function ESR12Z-4DX-UC, also for central control and group control. A 7Impulse switch ES61 and ESR61NP A 8Multifunction impulse switch with integrated relay function ESR61M and impulse switch for installation in lighting fi ttings ES75 A 9Technical data A10

The

sile

nt

revo

lutio

n

Switching on the future.

Electronic impulse switches

A

Page 6: Catalogo_Eltako_2009_ing

The silent revolutionWithout attracting particular attention by switching noise, the importance of electronic impulse switches with all their variants compared to conventional mechanical versions is growing steadily. They offer a highly reduced switching noise and further attractive advantages, such as multifunction, central control, zero passage switching for AC voltage, minimized control power demand and universal control voltage.

1) Applies to glow lamps with 170 V ignition voltage, for glow lamps with 90 V ignition voltage approx. ½ glow lamp current. 2) Glow lamp current independent from the ignition voltage. 3) Depends on the set function. 4) Will automatically be switched on starting at 110 V control voltage. 5) Control with 230 V or low-voltage possible. 6) If the control voltage is 230 V, but the phase conductor is different than the 230 V supply voltage, the universal voltage control input must be used due to the potential disconnection. 7) At the control input . 8) The relay contact can be open or closed when putting into operation. It will be synchronised at fi rst operation. 9) The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated. 10) Duplex technology: When switched with 230V/50Hz zero passsage switching is activated if L is connected to 1(L) and N to (N). Then additional standby loss of only 0.1 Watt.

Page A1 A2 A3 A4 A5 A6 A6 A7 A8 A8 A9 A9pi

ctog

ram

s

ES12

DX-

UC

ES12

-200

-8..2

30V

UC

ES12

-110

-8..2

30V

UC

ESR1

2NP-

230

V+8.

.230

V UC

ESR1

2M-8

..230

V UC

ES12

Z-20

0-8.

.230

V UC

ES12

Z-11

0-8.

.230

V UC

ESR1

2Z-4

DX-

UC

ES61

-8..2

30V

UC

ESR

61N

P-8.

.230

V UC

ESR

61M

-8..2

30V

UC

ES75

-12.

.24

V UC

Modular device for mounting on DIN rail EN 50022, number of modules 18 mm each

1 1 1 1 1 1 1 2

Built-in device for installation (e.g.fl ush-mounting box) and surfacemounting

Number NO contacts(not potential free)

1 2 1 (1)1+1

3)

2 3) 2 1 4x1 1 (1)1+1

3)

2 3) (1)

Number NC contacts potential free 1 1-23) 1 1-2

3)

Zero passage switching 10) 10)

Switching capacity 16A/250V AC

Switching capacity 10A/250V AC

Incandescent lamp load W 2000 2000 2000 3600 2000 2000 2000 2000 2000 2000 2000 500

Bistable relay(s) as relay contact(s) 8) 8) 8) 9) 9) 9) 9) 8) 9) 8)

Universal control voltage

Additional control voltage 230V 5) 5) 5) 6) 5) 6)

Control voltage 12 to 24V UC

Supply voltage same as control voltage

Supply voltage 230V 6) 6)

No standby loss 10)

Low standby loss

Glow lamp current (mA)at the control input 230V 5

1) 7) 5

1) 7) 5

1) 7)150 2) 5

1) 7)502)7)

Glow lamp current (mA ) at the control input for universal voltage 50

1) 4)50

1) 4)50

1) 4)

Off delay, switch-off early warning function and permanent light by push- button can be switched on

Multi circuit switch 3) 3)

Group switch 3) 3)

Central control electrically isolatedfrom the local control

Selection table electronic impulse switches

A0

Page 7: Catalogo_Eltako_2009_ing

1 NO contact potential free 16A/250V AC. Incandescent lamp load up to 2000W. No standby loss.Modular device for DIN-EN 50 022 rail mounting.1 module = 18 mm wide, 58 mm deep.

* With the Eltako Duplex technology the normally potential-free contacts can still switch in zero passage when switching 230V AC 50Hz and therefore drastically reduce wear. Simply connect the neutral conductor to the terminal (N) and L to 1 (L) for this. This gives an additional standby consumption of only 0.1 Watt.If the contact is used for controlling switching devices which do not perform zero passage switching themselves, (N) should not be connected because the additional closing delay otherwise causes the opposite effect.

Either universal control voltage 8 to 230 V UC at the control input +A1/A2 or 230 V with glow lamp current up to 5 mA at the control input (L)/-A2(N).

The simultaneous use of two potentials at the control inputs is not permitted.

Very low switching noise.

No permanent power supply necessary, therefore no standby loss.State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

By using a bistable relay coil power loss and heating is avoided even in the on mode. The relay contact can be open or closed when putting into operation. It will be synchronised at first operation.

Same terminal connection as the electromechanical impulse switch S12-100-.

ES12DX-UC *

Impulse switch ES12DX

Technical data page A10. Housing for operating instructions GBA12 page Z2.

A1

This impulse switch represents the latest generation of electronic switchgear:The electronics does not have an internal power supply and therefore no power is consumed in either the ON position or the OFF position. A control current flows only during a short control impulse of 0.2 seconds. This activates the microcontroller, reads the last switching state from the non-voltage memory, switches the bistable relay to its opposite state accordingly and rewrites the new switching state to memory.

Typical connectionEither Universal control voltage 8 to 230V UC

or control voltage 230 V withglow lamp current up to 5mA

ES12DX-UC 1 NO 16A EAN 4010312 107959 33,70 €/pc.

Recommended retail prices excluding VAT.

If N is connected, the zero passage switching is active.

Page 8: Catalogo_Eltako_2009_ing

2 NO contacts potential free 16A/250V AC. Incandescent lamp load up to 2000W. No standby loss.Modular device for DIN-EN 50 022 rail mounting.1 module = 18 mm wide, 58 mm deep.

Either universal control voltage 8 to 230 V UC at the control input +A1/A2 or 230 V with glow lamp current up to 5 mA at the control input (L)/-A2(N).

The simultaneous use of two potentials at the control inputs is not permitted.

Very low switching noise.

No permanent power supply necessary, therefore no standby loss.State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

By using a bistable relay coil power loss and heating is avoided even in the on mode. The relay contact can be open or closed when putting into operation. It will be synchronised at first operation.

Same terminal connection as the electromechanical impulse switch S12-200-.

Maximum current across both contacts 20A for 230 V.

ES12-200-8..230V UC

Impulse switch ES12-200

Technical data page A10. Housing for operating instructions GBA12 page Z2.

A2

This impulse switch represents the latest generation of electronic switchgear:The electronics does not have an internal power supply and therefore no power is consumed in either the ON position or the OFF position. A control current flows only during a short control impulse of 0.2 seconds. This activates the microcontroller, reads the last switching state from the non-voltage memory, switches the bistable relay to its opposite state accordingly and rewrites the new switching state to memory.

Typical connectionEither universal control voltage 8 to 230V UC

or control voltage 230 V with glow lamp current up to 5mA

ES12-200-8..230V UC 2 NO 16A EAN 4010312 108048 39,30 €/pc.

Recommended retail prices excluding VAT.

Page 9: Catalogo_Eltako_2009_ing

1 NO contact + 1 NC contact potential free 16A/250V AC. Incandescent lamp load up to 2000W.No standby loss.Modular device for DIN-EN 50 022 rail mounting.1 module = 18 mm wide, 58 mm deep.

Either universal control voltage 8 to 230 V UC at the control input +A1/A2 or 230 V with glow lamp current up to 5 mA at the control input (L)/-A2(N).

The simultaneous use of two potentials at the control inputs is not permitted.

Very low switching noise.

No permanent power supply necessary, therefore no standby loss.State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

By using a bistable relay coil power loss and heating is avoided even in the on mode. The relay contact can be open or closed when putting into operation. It will be synchronised at first operation.

Same terminal connection as the electromechanical impulse switch S12-110-.

ES12-110-8..230V UC

Impulse switch ES12-110

Technical data page A10. Housing for operating instructions GBA12 page Z2.

A3

Typical connectionEither universal control voltage 8 to 230V UC

or control voltage 230 V with glow lamp current up to 5mA

This impulse switch represents the latest generation of electronic switchgear:The electronics does not have an internal power supply and therefore no power is consumed in either the ON position or the OFF position. A control current flows only during a short control impulse of 0.2 seconds. This activates the microcontroller, reads the last switching state from the non-voltage memory, switches the bistable relay to its opposite state accordingly and rewrites the new switching state to memory.

ES12-110-8..230V UC 1NO+1 NC 16 A EAN 4010312 108055 39,30 €/pc.

Recommended retail prices excluding VAT.

Page 10: Catalogo_Eltako_2009_ing

Impulse switch with integrated relay function* ESR12NP

1 NO contact not potential free 16A/250V AC. Incandescent lamp load up to 2000W. Off delay impulse switch with switch-off early warning and push-button permanent light switchable. Standby loss 0.5 watt only.Modular device for DIN-EN 50 022 rail mounting.1 module = 18 mm wide, 58 mm deep.

Zero passage switching to protect contacts and lamps. This prolongs in particular the lifetimeof energy saving lamps.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

Control voltage 230 V. In addition electrically isolated universal voltage from 8 to 230 V UC.Supply voltage and switching voltage 230 V.

Very low switching noise. If the function ESV is set, defi nitely variable off-delay time RV from 2 to 120 minutes, settable by minute scale.

Contact position indication with two LEDs. This starts blinking in case of a blocked push-button(not if the function ER is set).

Glow lamp current up to 150 mA only at the control input 230 V independent from ignition voltage (not if the function ER is set).

In case of a power failure the system is disconnected in a preset sequence.

The functions ES, ESV or ER are selectable by means of a rotary switch.

ES = Impulse switch

ER = Switching relay

ESV = Impulse switch with off delay. The impulse switch automatically disconnects after the set delay is timed out if a manual OFF command has not been given. Infi nitely variable time range up to120 minutes.

ESV = If switch-off early warning is set the stairwell lighting starts fl ickering approximately+ 30 seconds before timeout at repeated shorter time intervals. During this process reset is possible.

ESV = If push-button permanent light is set permanent light can be switched on by+ pressing longer than 1 sec. This switches off automatically after 2 hours or by an operation longer than 2 seconds.

ESV If both switch-off early warning function and permanent light by push-button are+ set, the switch-off early warning function is activated before switching off the permanent light.

This electronic impulse switch does not need a base load for switching lights in rooms which are monitored by a FR12-230V mains disconnection relay.

* This describes our devices wich can be used as impulse switches as well as switching relays. This halves the number of types and increases the stock turnover.

ESR12NP-230V+8..230V UC

Function rotary switches

Standard setting ex factory.

Technical data page A10. Housing for operating instructions GBA12 page Z2.

A4

= switch-off early warning

= push-button permanent light

= switch-off early warning and push-button

permanent light

Typical connection

ESR12NP-230V+8..230V UC 1 NO 16A EAN 4010312 107928 37,20 €/pc.

Recommended retail prices excluding VAT.

Page 11: Catalogo_Eltako_2009_ing

Multifunktions-Stromstoß-Schaltrelais* ESR12MMultifunction impulse switch with integrated relay function* ESR12M

1 +1 NO contacts potential free 16A/250V AC. Incandescent lamp load up to 2000W. Standby loss 0.5 watt only.Modular device for DIN-EN 50 022 rail mounting.1 module = 18 mm wide, 58 mm deep.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

Universal control voltage 8 to 230 V UC. Supply voltage is same as the control voltage

Contact position indication with two LEDs. Very low switching noise.

By using bistable relays coil power loss and heating is avoided even in the on mode. The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated.

In case of a power failure the system is disconnected in a preset sequence.

From 110 V control voltage and in switching positions 2S, WS, SS and GS glow lamp currentup to 50 mA.

The functions of the big rotary switch are preselected using the small rotary switch ES/ER.The setting ER selects the function in brackets. 18 different functions are selectable using the big rotary switch: OFF = Permanent OFF

2xS = 2-fold impulse switch with 1 NO contact each, control inputs A1 and A3 (2xR) = 2-fold switching relay with 1 NO contact each, control inputs A1 and A3

2S = Impulse switch with 2 NO contacts (2R) = Switching relay with 2 NO contacts

WS = Impulse switch with 1 NO contact and 1 NC contact (WR) = Switching relay with 1 NO contact and 1 NC contact

SS1 = Impulse multi circuit switch 1 + 1 NO contacts for switching sequence 1 (RR) = Switching relay (closed-circuit current relay) with 2 NC contacts

SS2 = Impulse multi circuit switch 1 + 1 NO contacts for switching sequence 2 (EAW) = Impulse relay for fleeting NO contact and fleeting NC contact with 1 + 1 NO contacts, wiping time 1 sec each

SS3 = Impulse multi circuit switch 1 + 1 NO contacts for switching sequence 3 (EW) = Impulse relay for fleeting NO contact with 1 NO contact and 1 NC contact, wiping time 1 sec

GS = Impulse group switch 1 + 1 NO contacts (AW) = Impulse relay fleeting NC contact with 1 NO contact and 1 NC contact, wiping time 1 sec

RS = Switch with A1= set control input and A3 = reset control input (GR) = Group relay 1 + 1 NO contacts

ON = Permanent ON

Switching sequence SS1: 0 - contact 1 (1-2) - contact 2 (3-4) - contacts 1 + 2Switching sequence SS2: 0 - contact 1 - contacts 1 + 2 - contact 2Switching sequence SS3: 0 - contact 1 - contacts 1 + 2Switching sequence GS: 0 - contact 1 - 0 - contact 2GR: Relay with alternating closing contacts

The control inputs A1 and A3 have the same functions except for 2xS, 2xR and RS.

* This describes our devices wich can be used as impulse switches as well as switching relays. This halves the number of types and increases the stock turnover.

ESR12M-8..230V UC

Function rotary switches

Standard setting ex factory.

Typical connection

Technical data page A10. Housing for operating instructions GBA12 page Z2.

8-230 V UC

A5

check-backsignal

ESR12M-8..230V UC 1+1 NO 16A EAN 4010312 107935 51,00 €/pc.

Recommended retail prices excluding VAT.

Page 12: Catalogo_Eltako_2009_ing

2 NO contacts potential free 16A/250V AC. Incandescent lamp load up to 2000W. Standby loss 0.5 watt only. Central control priorities selectable. Modular device for DIN-EN 50 022 rail mounting.1 module = 18 mm wide, 58 mm deep. State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.Local universal control voltage 8 to 230 V UC. In addition control inputs 8 to 230 V UC centralON and central OFF, electrically isolated from the local input. Supply voltage same as the localcontrol voltage. Very low switching noise. Glow lamp current starting at 110 V control voltageup to 50 mA in positions 1 to 3 and 5 to 7 of the rotary switch, independent from the ignitionvoltage of the glow lamps.By using a bistable relay coil power loss and heating is avoided even in the on mode. The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated.Maximum current across both contacts 20 A for 230 V. Contact position indication with LED. This starts blinking after 15 seconds in case of a inhibited push-button, not in position 4+8 of the rotary switch.With the upper rotary switch this impulse switch can be partly or completely excluded fromcentral control: ZE+ZA = central ON and central OFF, ZE = central ON only, ZA = central OFF only, ZE+ZA = no central controlThe lower rotary switch sets several priorities. These determine which other control inputs areinhibited as long as onother control input is excited permanently.Furthermore, here it is decided if the switch position should be kept or not after a power failure:In positions 1 to 4 of the rotary switch the switch position remains unchanged, in positions 5 to 8 it is switched off. Incoming central commands are executed immediately after the powersupply returns.OFF = Permanent OFF, ON = Permanent ON1 and 5 = No priority. Also if central control inputs are excited permanently, it is possible to operate the device by pushing a local push-button. The last central command is executed. This is the setting ex works.2 and 6 = Priority for central ON and OFF. Local push-buttons are temporarily inhibited. However, continuous excitation central OFF has priority over continuous excitation central ON.3 and 7 = Priority for central ON and OFF. Local push-buttons are temporarily inhibited. However, continuous excitation central ON has priority over continuous excitation central OFF.4 and 8 = Priority for permanently excited local push-button. In the meantime central commands are not executed. In these positions a glow lamp current is not permitted.

Impulse switch with potential free contacts ES12Z,also for central control

ES12Z-200-8..230V UC

Function rotary switches

Standard setting ex factory.

Typical connection

1 NO contact + 1 NC contact potential free 16A/250 V AC.Incandescent lamp load up to 2000W. Standby loss 0.5 watt only. Central control priorities selectable.All functions same as ES12Z-200, but with 1 NO contact and 1 NC contact.

ES12Z-110-8..230 V UC

Technical data page A10.

Technical data page A10. Housing for operating instructions GBA12 page Z2.

A6

check-backsignal

localon/off

ES12Z-200-8..230V UC 2 NO 16A EAN 4010312 107690 50,80 €/pc.

ES12Z-110-8..230V UC 1 NO + 1 NC 16 A EAN 4010312 107683 50,80 €/pc.

Recommended retail prices excluding VAT.

cent

ral o

n

cent

ral o

ff

Page 13: Catalogo_Eltako_2009_ing

4-fold impulse switch with integrated relay function ESR12Z-4DX-UC

A7

Also for central control and group control. With 4 independent impulse switch functions, 1 NO contact each potential free 16A/250V AC, incandescent lamp load up to 2000W. Standby loss 0.4 watt only.Modular devices for DIN-EN 50022 rail mounting. 2 modules = 36mm wide, 58mm deep. * Eltako Duplex technology allows you to switch 3 of the 4 normally potential free contacts in zero passage switching when 230V A/C voltage 50Hz is switched. This drastically reduces wear. To achieve this, simply connect the N conductor to the terminal (N) and the phase conductors to 1(L), 3(L) or 5(L). This results in an additional standby consumption of only 0.1 watt. If the channels are used to control switchgear that has no zero passage switching, (N) should not be connected, otherwise the additional off-delay would have the opposite effect.Local universal control voltage 8 to 230V UC. In addition universal control inputs central ON and central OFF for 8 to 230V UC, electrically isolated from the local inputs.With additional group control inputs ON and OFF for 8..230V UC. Same potential like the local control inputs. Groups of these impulse switches can be controlled separately using the group control inputs.Supply voltage like the local control voltage.State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays.By using a bistable relay causing coil power loss and heating is avoided even in the on mode. The switched consumers may not be connected to the mains before the short automatic synchronisation after installation has terminated. Central commands always have priority, local control inputs are blocked as long as central commands are activated. In case of a power failure the system is disconnected in a defined mode.With the upper rotary switch this impulse switch with integrated relay function can be partly or completely excluded from central control:ZE+ZA = central ON and central OFF ZE = central ON onlyZA = central OFF only ZE+ZA = no central controlWith the middle rotary switch ES/ER the functions of the lower rotary switch will be preselected. The setting ER selects the function in brackets. With the lower rotary switch 18 different functions may be selected:OFF = Permanent OFF; ON = Permanent ON4xS = 4-fold impulse switch with 1 NO contact each, control inputs A1, A3, A5 and A7(4xR) = 4-fold switching relay with 1 NO contact each, control inputs A1, A3, A5 and A74S = Impulse switch with 4 NO contacts(4R) = Switching relay with 4 NO contacts2S/WS = Impulse switch with 3 NO contacts and 1 NC contact(2R/WR) = Switching relay with 3 NO contacts and 1 NC contact 2WS = Impulse switch with 2 NO contacts and

2 NC contacts (2WR) = Switching relay with 2 NO contacts and

2 NC contacts SSa = Impulse multi circuit switch 2+2 NO contacts for

switching sequence 0-2-2+4-2+4+6; check back signal 8

(4RR) = closed-circuit current relay with 4 NC contacts SSb = Impulse multi circuit switch 2+2 NO contacts for

switching sequence 0-2-2+4-2+4+6-2+4+6+8 (EW) = Impulse relay for fleeting NO contact with

3 NO contacts and 1 NC contact, wiping time 1 sec GS = Impulse group switch. Switching sequence

0-2-0-4-0-6-0; check back signal 8 (AW) = Impulse relay fleeting NC contact with

3 NO contacts and 1 NC contact, wiping time 1 sec RS = Switch with 4 NO contacts, A1= set control input

and A3 = reset control input (GR) = Group relay 1+1+1+1 NO contacts

ESR12Z-4DX-UC *

ESR12Z-4DX-UC 4 x 1 NO 16 A EAN 4010312 108130 87,80 €/pc.

Recommended retail prices excluding VAT.

Function rotary switches

Standard setting ex factory.

Typical circuit with central control and group control

Technical data page A10. Housing for operating instructions GBA12 page Z2.

loca

l on/

off

loca

l on/

off

grou

p on

loca

l on/

off

loca

l on/

off

grou

p of

f

cent

ral o

n

cent

ral o

ff

If N is connected, the zero passage switching is active at the contacts 1-2, 3-4 and 5-6.

Page 14: Catalogo_Eltako_2009_ing

Impulse switch ES61Impulse switch with integrated relay function* ESR61NP

1 NO contact potential free10A/250V AC. Incandescent lamp load up to 2000W. No standby loss.For installation and surface mounting. 45 mm long, 55 mm wide, 18 mm deep.State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

Either universal control voltage 8 to 230 V UC at the control input +A1/A2 or 230 V with a glow lamp current up to 5 mA at the control input (L)/-A2(N).

Using two potentials simultaneously at the control inputs is not permitted. Very low switching noise.No permanent power supply necessary, therefore no standby loss.By using a bistable relay coil power loss and heating is avoided even in the on mode. The relay contact can be open or closed when putting into operation. It will be synchronised at first operation.

1 NO contact not potential free 10A/250V AC. Incandescent lamp load up to 2000W. Off delay impulse switch with switch-off early warning and push-button permanent light switchable. Standby loss 0.5 watt only.For installation and surface mounting. 45 mm long, 55 mm wide, 18 mm deep.Zero passage switching to protect contacts and lamps. This prolongs in particular the lifetimeof energy saving lamps.State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.By using a bistable relay coil power loss and heating is avoided even in the on mode. The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated.Control voltage 230 V. In addition electrically isolated universal control voltage from 8 to 230 V UC. Supply voltage and switching voltage 230 V.Very low switching noise. Variable time range up to 120 minutes in the function ESV.At the control input push-buttons with a glow lamp current up to 50 mA can be connected.If the timing period is set to minimum in the function ESV, the release delay is switched off.The standard impulse switch function ES is then set.The function ER is selectable. If the function ER is selected a glow lamp current is not permitted. Only the control input A1- A2 should be used.If switch-off early warning function is switched on, the light starts flickering approx. 30 seconds before time-out. This is repeated three times at decreasing time intervals.If the permanent light function is switched on, the function can be activated by pressing the push-button for longer than 1 second. This function switches off automatically after 2 hours or by pressing the push-button for longer than 2 seconds.If both switch-off early warning function and permanent light by push-button are set,the switch-off early warning function is activated before switching off the permanent light.

* This describes our devices wich can be used as impulse switches as well as switching relays. This halves the number of types and increases the stock turnover.

ES61-8..230 V UC

ESR61NP-8..230 V UC

Technical data page A10.

Function rotary switches

Standard setting ex factory.

Technical data page A10.

A8

Typical connection

Typical connection

This impulse switch represents the latest generation of electronic switchgear:The electronics does not have an internal power supply and therefore no power is consumed in either the ON position or the OFF position. A control current flows only during a short control impulse of 0.2 seconds.

ES61-8..230V UC 1 NO 10A EAN 4010312 107966 37,00 €/pc.

ESR61NP-8..230V UC 1 NO 10A EAN 4010312 107911 39,20 €/pc.

Recommended retail prices excluding VAT.

Page 15: Catalogo_Eltako_2009_ing

1+1 NO contacts potential free 10A/250V AC. Incandescent lamp load up to 2000W. No standby loss.For installation and surface mounting. 45 mm long, 55 mm wide, 32 mm deep.State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.Universal control voltage 8 to 230V UC.No permanent power supply necessary, therefore no standby loss.By using bistable relays coil power loss and heating is avoided even in the on mode.The relay contact can be open or closed when putting into operation. It will be synchronised at first operation.The functions of the second rotary switch are preselected using the rotary switch ES/ER.The setting ER selects the function in brackets. 10 different functions are selectable. 2S = Impulse switch with 2 NO contacts (2R) = Switching relay with 2 NO contacts WS = Impulse switch with 1 NO contact and 1 NC contact (WR) = Switching relay with 1 NO contact and 1 NC contact SS1 = Impulse multi circuit switch 1 + 1 NO contacts for switching sequence 1 (RR) = Switching relay (closed-circuit current relay) with 2 NC contacts SS2 = Impulse multi circuit switch 1 + 1 NO contacts for switching sequence 2 (EW) = Impulse relay for fleeting NO contact with 1 NO contact and 1 NC contact, wiping time 1 sec GS = Impulse group switch 1 + 1 NO contacts (GR) = Group relay 1 + 1 NO contactsSwitching sequence SS1: 0 - contact 1(1-2) - contact 2 (3-4) - contacts 1 + 2Switching sequence SS2: 0 - contact 1 - contacts 1 + 2 - contact 2Switching sequence GS: 0 - contact 1 - 0 - contact 2GR: Relay with alternating closing contacts

For installation in lighting fi ttings.1 NO contact not potential free 10A/250V AC. With VDE approval. Standby loss 0.1 watt only.Built-in device for installation. 85 mm long, 40 mm wide, 28 mm deep.With integrated transformer for electrical isolation between control circuit and switching circuitto comply with the requirements for safety extra-low voltage.Control voltage 12 to 24V UC, control current 10 mA at 24V. Continuous power supply 230 V.Incandescent lamps and halogen lamps load 1) up to 500 W and fluorescent lamps with conventional ballast units in lead-lag circuit up to 1000 VA.Fluorescent lamps with conventional ballast units parallel compensated 300 VA.Temperatures at the mounting location between -20°C and +50°C.Min. command pulse duration/command pause 20/300 ms. Connections on the low voltage side: 4-pole pin receptacle for STOCKO MKF 13264-6-0-404 plug, 230 V connections: 6-pole terminal strip with plug-in terminals. max. conductor cross section 2,5 mm². One STOCKO plug comes with each device.1) For lamps with 150W max.

ES75-12..24 V UC

Multifunction impulse switch with integrated relay function ESR61M, impulse switch ES75

Technical data page A10.

Technical data page A10.

A9ESR61M-8..230V UC

Function rotary switches

Typical connection

Side view

ESR61M-8..230V UC 1 + 1 NO 10 A EAN 4010312 108079 50,80 €/pc.

ES75-12..24V UC 1 NO 10 A EAN 4010312 101063 38,30 €/pc.

Recommended retail prices excluding VAT.

Page 16: Catalogo_Eltako_2009_ing

ContactsES12 a) ESR12NP ESR12M b) ES12Z b)

ESR12Z-4DX b)

ES61 a)

ESR61M a)

ESR61NP b)

Contact material /contact gap AgSnO2/0.5 mm AgSnO2/0.5 mm AgSnO2/0.5 mm AgSnO2/0.5 mm AgSnO2/0.5 mm AgSnO2/0.5 mm

Spacing of control connections/contact control connections C1-C2 or A1-A2/contact

6 mm–

3 mm6 mm

6 mm–

6 mm–

3 mmESR61M: 6 mm

3 mm6 mm

Test voltage contact /contact ES12-200/110:2000 V

– 4000 V 4000 V ESR61M:2000 V

Test voltage control connection /contactTest voltage C1-C2 or A1-A2/contact

4000 V–

2000 V4000 V

4000 V–

4000 V–

2000 V4000 V

2000 V4000 V

Rated switching capacity 16 A /250 V AC 16 A /250 V AC 16 A /250 V AC 16 A /250 V AC 10 A /250 V AC 10 A /250 V AC

Incandescent lamp and halogen lamp load 1) 230 V 2000 W 2000 W 2000 W 2000 W 2000 W 2000 W

Fluorescent lamp load with KVG* in lead-lagor non compensated

1000 VA 1000 VA 1000 VA 1000 VA 1000 VA 1000 VA

Fluorescent lamp load with KVG* shunt-compensated or with EVG*

500 VA 500 VA 500 VA 500 VA 500 VA 500 VA

Compact fl uorescent lamps with EVG* and energy saving lamps ESL

I on 70 A /10 ms 2) 3)

15x7 W10x20 W

I on 70 A /10 ms 2)

I on 70 A /10 ms 2) 3)

I on 70 A /10 ms 2)

15 x7 W10 x 20 W

Max. switching current DC1: 12 V/24 V DC 8 A – 8 A 8 A 8 A –

Life at rated load, cos = 1 resp. forincandescent lamps 1000 W at 100/h

> 10 5 > 10 5 > 10 5 > 10 5 > 10 5 > 10 5

Life at rated load, cos = 0.6 at 100/h > 4 x104 > 4 x104 > 4 x104 > 4 x104 > 4 x104 > 4 x104

Max. operating cycles 103/h 103/h 103/h 103/h 103/h 103/h

Terminal cross-section 2-fold/3-fold 12 mm2 / – 12 mm2 / – 12 mm2 / 7 mm2 12 mm2 / 7 mm2 M3 M3

Maximum conductor cross-section 2-fold/3-fold 6 mm2 / – 6 mm2 / – 6 mm2 / 4 mm2 6 mm2 / 4 mm2 2.5mm2 2.5mm2

Screw head slotted/Phillips, pozidriv slotted slotted

Shock-hazard protection (on the device) VDE 0106 part 100 – –

Electronics

Time on (also for central on/off) 100% 100% 100% 100% 100% 100%

Max./min. temperature at mounting location +50°C/-20°C +50°C/-20°C +50°C/-20°C +50°C/-20°C +50°C/-20°C +50°C/-20°C

Standby loss (active power) – 0.5 W 0.5 W 0.5 W – 0.5 W

Control current 230 V-control input local 25 mA 10 mA – –25 mAESR61M: –

10 mA

Control current universal control voltageall control voltages (< 5 s) ± 20%8/12/24/230 V (<10 s) ± 20%

–1.5 mA (15 mA)–

––2/4/9/5(100) mA

––0.1/ 0.1/0.2 / 1mA

––0.6 /1/2/10 mA

–1.5 mA (15 mA)ESR61M: 4 mA

––2/4/9/5(100) mA

Control current central8/12/24/230 V (<10 s) ± 20%

– – –2/4/9/5(100) mA

– –

Max. parallel capacitance (approx. length) of single control lead at 230 V AC

0,3 μF(1000 m)A1-A2: 0,06 μF(200 m)

ES: 0,3μF(1000 m)ER: 3nF (10 m)C1-C2: 15nF (50 m)

ES: 0,3μF(1000 m)ER: 0,06μF(200 m)

0,3 μF(1000 m)

: 0,3μF(1000 m)A1-A2: 0,06 μF(200 m)ESR61M: 0,5nF (2m)

0,06 μF(200 m)

A1-A2: 0,3 μF(1000 m)

Max. parallel capacitance (approx. length) of central control lead at 230 V AC

– – –0.9 μF(3000 m)

– –

Technical data electronic impulse switches, also for central control

Compliance with: EN 61000-6-3, EN 61000-6-1 and EN 60 669

A10

a) Bistable relay as relay contact. The relay contact can be open or closed when putting into operation. It will be synchronised at fi rst operation. b) Bistable relay as relay contact. The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated. 1) For lamps with 150W max. 2) A 40-fold inrush current must be expected for electronic ballast devices. For steady loads of 1200W or 600W use the current-limiting relay SBR12 or SBR61. Product group G, page G3. 3) If zero passage switching is activated at the ES12DX or the ESR12Z-4DX: 15x7W rsp. 10x20W.

*EVG = electronic ballast units; KVG = conventional ballast units

Page 17: Catalogo_Eltako_2009_ing

Selection table for universal dimmer switches, capacity enhancer and 1-10V controllers B0Universal dimmer switch EUD12NPN B1Universal dimmer switch for central control EUD12Z B2Multifunctions universal dimmer switch EUD12M B3Universal dimmer switch for mains disconnection switching EUD12F B4Capacity enhancer for universal dimmer switches LUD12 B51-10V control dimmer switch for electronic ballast units SDS12 B61-10V controller for universal dimmer switches SUD12 B7Universal dimmer switch EUD61NP without N connection B8Universal dimmer switch EUD61NPN B9Multifunctions universal dimmer switch EUD61M B10Typical circuits B11Technical data B12

The

Ener

gy

Save

rs

Switching on the future.

Universal dimmer switches, capacity enhancer and 1-10V controllers

B

Page 18: Catalogo_Eltako_2009_ing

The Energy Savers Set the mood and reduce energy costs at the same time - a fascinating combination. The dimming of incandescent lamps and halogen lamps in combination with soft ON and soft OFF, prolongs their lifetime considerably. This applies also to the new infi nitely dimmable energy saving lamps. Only universal dimmers with the marking R, L, C recognize automatically the connected load and adjust their dimming function accordingly. Other dimmers have to be exchanged if lamps with other kind of loads are used later. Only dimmer switches with additional ESL marking are optimized for dimmable energy saving lamps. We recommend Dimmerable by .

Selection table for universal dimmer switches, capacity enhancer and 1-10V controllers

Page B1 B2 B3 B4 B5 B6 B7 B8 B9 B10pi

ctog

ram

s

EUD1

2NP

N

EUD1

2Z-

8..2

30V

UC

EUD1

2M

-UC

EUD1

2F

LUD1

2-2

30V

SDS1

2/1

-10

V

SUD1

2/1

-10

V

EUD

61N

P-23

0V

EUD

61N

PN-U

C

EUD

61M

-UC

Modular device for DIN EN 50022 railmounting, number of modules 18 mm each

1 1 1 1 1 1 1

Built-in device for installation (e.g. fl ush-mounting box) and surface mounting

Dimming R, L and C loads 5) 1-10VEVG* 7)

Optimized dimming function for dimmable energy saving lamps ESL

Power MOSFET up to 500 W (nearly unlimited number of switching cycles)

1) 7)

Increase of capacity with capacity enhancer LUD12-230V 7)

Zero passage switching

Minimum brightness level adjustable 6) 6)

Universal control voltage 8 to 230V UC 6) 6)

Supply voltage 230 V

Low standby loss

Glow lamp current (mA) 2) 4) 5 5 3) 5 3) 5 6)

Central control electrically isolated from the local input 6) ( ) 6)

Switching operation for children's rooms 6) 6)

Snooze function 6) 6)

Multifunction 6)

B2B0

1) Power MOSFET 300W. 2) Applies to glow lamps with 170 V ignition voltage, for glow lamps with 90 V ignition voltage approx. ½ glow lamp current. 3) Depends on the set function. 4) Will automatically be switched on from 110 V control voltage. 5) Same load as main dimmer switch or separate R, L or C load, depending on circuit. 6) This specification refers to EUD12Z or EUD12M, which is connected in series. 7) This specification refers to the connected EUD12M, EUD12Z or LUD12 depending on the selected mode.

*EVG = electronic ballast units

Page 19: Catalogo_Eltako_2009_ing

Darstellung ist die Standard-einstellung ab Werk.

Power MOSFET 500W. Standby loss 0.1 watt only.Modular device for DIN EN 50022 rail mounting.1 module = 18 mm wide, 58 mm deep.Universal dimmer switch for R, L and C loads up to 500 watt, depending on ventilation conditions. Dimmable energy saving lamps ESL up to 100 watt. Automatic detection of load R+L or R+C. ESL is manually settable.Universal control voltage input 8 to 230V UC, electrically isolated from the 230 V supply voltage and switching voltage.

Zero passage switching with soft start and soft OFF to protect lamps.The minimum brightness level (completely dimmed down) can be adjusted with the rotary switch % , e.g. for dimmable energy saving lamps.

The dimming speed can be adjusted with the dimming speed rotary switch. Simultaneously the soft on and soft off period is changed.

The settings ESL consider the special conditions regarding dimmable energy saving lamps:The starting operation is optimized and the dimm speed changes logarithmically. In these settings the special switching operation for children’s rooms is not possible and no wound (inductive) transformer must be dimmed. In position -ESL Memory is switched off. This can be of advantage for energy saving lamps because cold energy saving lamps require a higher minimum brightness as it will possibly be stored in Memory for warmer energy saving lamps.

Short-time control commands switch on/off, permanent control varies the brightness to the maximum level.

An interruption of control changes the direction of dimming. The setting of the brightness level is stored after switching off.

In case of a power failure the switching position and the brightness level are stored. If applicable the dimmer will be switched on at the stored brightness level after the supply voltage is recovered.

Glow lamp current up to 5 mA starting at 110 V.

Automatic electronic overload protection and over-temperature switch-off.

With special switching operation for children's rooms: If the light is switched on by holdingdown the push-button, it starts at the lowest brightness level after approx. 1 second withoutmodifying the last stored brightness level.

Snooze function: With a double impulse the lighting is dimmed down from the current dimming position to the minimum brightness level and switched off. The current dimming position as well as the adjustable minimum brightness level determine the dimming time (max. = 60 minutes) which can be reduced as required. It can be switched off at any time by short-time control commands during the lighting is dimmed down. Holding down the push-button during the dimming down process dims up and stops the snooze function.

Mixing of L loads (inductive loads, e.g. wound transformers) and C loads (capacitive loads, e.g. electronic transformers) is not permitted. R loads (ohmic loads, e.g. 230V incandescentlamps and halogen lamps) may be added anytime.

Mixing of L loads and C loads is possible with dimmer switches EUD12Z (description page B2) and EUD12M (page B3) in connection with capacity enhancer LUD12 (page B5).

EUD12NPN-UC

Universal dimmer switch EUD12NPN

Function rotary switch

Technical data and typical circuit page B12. Housing for operating instructions GBA12 page Z2.

B1B1

EUD12NPN-UC Power MOSFET 500W EAN 4010312 107843 54,30 €/pc.

Recommended retail prices excluding VAT.

Standard setting ex factory.

N

N

L

L

max.500W

L

N

+A1 -A2

N(-)

L(+)8-230V UC

Typical connection

Page 20: Catalogo_Eltako_2009_ing

Power MOSFET 500W. Standby loss 0.1 watt only.Modular device for DIN EN 50022 rail mounting.1 module = 18 mm wide, 58 mm deep.Universal dimmer switch for R, L and C loads up to 500 W. Automatic detection of load R+L or R+C.The EUD12Z cannot switch energy saving lamps ESL because no minimum brightness level can be set.Up to 3600 W with capacity enhancers LUD12-230V (description page B5) at the terminals X1 and X2. Universal voltage control input from 8 to 230 V UC and additionally the universalvoltage control inputs 8 to 230 V UC central ON and central OFF. The control inputs are electrically isolated from the 230V supply voltage and switching voltage.Zero passage switching with soft start and soft OFF to protect lamps.Short-time control commands switch on/off, permanent control varies the brightness to themaximum level. A interruption of control changes the direction of dimming. The setting of the brightness level is stored after switching off.Glow lamp current up to 5 mA starting at 110 V (not for priorities 4 and 8).Automatic electronic overload protection and over-temperature switch-off.The LED below the upper rotary switch on the front indicates a local or central control.During local control it starts blinking after 15 seconds if a push-button is inhibited.With special switching operation for children's rooms: If the light is switched on by holdingdown the push-button, it starts at the lowest brightness level after approx. 1 second withoutmodifying the last stored brightness level.Snooze function: With a double impulse the lighting is dimmed down from the current dimming position and finally switched off. The current dimming position determines the dimming time (max. = 60 minutes) which can be reduced as required. It can be switched off at any time by short-time control commands during the lighting is dimmed down. Holding down the push-button during the dimming down process dims up and stops the snooze function.The upper rotary switch adjusts the dimming speed. The duration of soft start and soft OFF ischanged simultaneously.This impulse dimmer switch can be operated completely or partially as central control device.The middle rotary switch adjusts the central control. ZE+ZA = central ON and central OFF, ZE = central ON only, ZA = central OFF only, ZE+ZA = no central controlThe lower rotary switch sets several priorities. These determine which other control inputs areinhibited as long as onother control input is excited permanently.Furthermore, here it is decided if the switch position should be kept or not after a power failure:In positions 1 to 4 of the rotary switch the switch position remains unchanged, in positions 5 to 8 it is switched off. Incoming central commands are executed immediately after the power supply returns.OFF = Permanent OFF1 and 5 = No priority. Also if central control inputs are excited permanently, it is possible to operate the device by pushing a local push-button. The last central command is executed. This is the setting ex works.2 and 6 = Priority for central ON and OFF. Local push-buttons are temporarily inhibited. However, continuous excitation central OFF has priority over continuous excitation central ON. 3 and 7 = Priority for central ON and OFF. Local push-buttons are temporarily inhibited. However, continuous excitation central ON has priority over continuous excitation central OFF.4 and 8 = Priority for permanently excited local push-button. In the meantime central commands are not executed. In these positions a glow lamp current is not permitted.ON = Permanent ON

Universal dimmer switch EUD12Z for central control

EUD12Z-8..230V UC

Function rotary switches

Standard setting ex factory.

Technical data page B12. Housing for operating instructions GBA12 page Z2.

B2

Typical connection

EUD12Z-8..230V UC Power MOSFET 500 W EAN 4010312 107850 65,10 €/pc.

Recommended retail prices excluding VAT.

cent

ral o

ffce

ntra

l on

Page 21: Catalogo_Eltako_2009_ing

POWER MOSFET 500W. Standby loss 0.1 watt only.Modular device for DIN EN 50022 rail mounting. 1 module = 18 mm wide, 58 mm deep.Universal dimmer switch for R, L and C loads up to 500 watt. Dimmable energy saving lamps ESL up to 100 watt. Automatic detection of load R+L or R+C. ESL is manually settable.Up to 3600 W with capacity enhancers LUD12-230V (description page B5) at the terminals X1 and X2 (not ESL). Universal control voltage 8 to 230V UC and additionally the universalvoltage control inputs 8 to 230 V UC central ON and central OFF. The control inputs areelectrically isolated from the supply voltage and switching voltage.Zero passage switching with soft start and soft OFF to protect lamps.Contact position indication with LED below the upper rotary switch. This starts blinking after 15 seconds if a push-button is jammed and if one of the functions EUD, ESV or TLZ is set.The minimum brightness level can be adjusted with the rotary switch %, e.g. for dimmable energy saving lamps ESL.In case of a power failure the switching position and the brightness level are stored. If applicable the dimmer will be switched on at the stored brightness level after the supply voltage is recovered.From 110 V control voltage glow lamp current up to 5 mA (not for ER and TI).Automatic electronic overload protection and over-temperature switch-off.The lower rotary switch sets 10 different functions:EUD = Universal dimmer switch. The dimming speed t and the minimum brightness level %min/max are adjustable. Short-time control commands switch on/off, permanent control varies the brightness to the maximum level. A interruption of control changes the direction of dimming. The setting of the brightness level is stored after switching off. Switching operation for children‘s rooms: If the light is switched on by holding down the push-button, it starts at the lowest brightness level after approx. 1 second without modifying the last stored brightness level. Snooze function: With a double impulse the lighting is dimmed down from the current dimming position to the minimum brightness level and switched off. The current dimming position as well as the adjustable minimum brightness level determine the dimming time (max. = 60 minutes) which can be reduced as required. It can be switched off at any time by short-time control commands during the lighting is dimmed down. Holding down the push-button during the dimming down process dims up and stops the snooze function.-mem = Like the setting EUD, but the adjustment of the brightness level is not stored after swit-ching off. It is always switched on at the maximum brightness level.+ESV = Like the setting EUD. In addition with adjustment of the off delay t up to 90 minutes, if the manual OFF command is not given. The switch off early warning function before time-out can be adjusted by dimming down with %min/max from 0 to 3 minutes. The dimming speed is preset at a medium value. The brightness level is preset with the minimum value.min = Universal dimmer switch. When applying the control voltage it is switched on at the minimum brightness level, which is set with %min/max. Afterwards the light is dimmed up in dimming time t (max. = 90 minutes) up to maximum level. If the control voltage is removed it is switched off instantly, also during the dimming time.minmax = Function like the setting min, but when the control voltage is removed it is dimmed down to the adjusted minimum brightness level. After that is switched off.TLZ = Staircase time switch, with switch off early warning function through dimming which can be switched on. With incrementing (the time can be extended) and permanent light by push-button. Variable time range settable from 1 to 9 minutes. Early warning time up to 3 minutes with %min/max. Also for dimmable energy saving lamps ESL.TI = Clock generator with adjustable cycle times t from 0.1 to 0.9 second. The break time can be set from -50% at %min to +100% at %max. Mid-position of %min/max: closing time = break time.

ER = Switching relay. Adjustment of soft start and soft OFF with the rotary switch t. Adjustment of dimming level %min/max between minimum and maximum brightness level.The settings ESL consider the special conditions regarding dimmable energy saving lamps: The starting operation is optimized and the dimm speed changes logarithmically. In these settings the special switching operation for children’s rooms is not possible and no wound (inductive) transformer must be dimmed. In position -ESL Memory is switched off. This can be of advantage for energy saving lamps because cold energy saving lamps require a higher minimum brightness as it will possibly be stored in Memory for warmer energy saving lamps.

EUD12M-UC

Multifunktions-Stromstoß-Schaltrelais* ESR12MMultifunction universal dimmer switch EUD12M

Technical data and typical circuit page B12. Housing for operating instructions GBA12 page Z2. Available 02/2009

B3

EUD12M-UC Power MOSFET 500W EAN 4010312 107836 65,10 €/pc.

Recommended retail prices excluding VAT.

Function rotary switches

Standard setting ex factory.

Typical connection

cent

ral o

ffce

ntra

l on

Page 22: Catalogo_Eltako_2009_ing

Power MOSFET 300W. Standby loss 0.1 watt only.Modular device for DIN EN 50022 rail mounting.1 module = 18 mm wide, 58 mm deep.Universal dimmer switch for R, L and C loads up to 300 watt, depending on ventilation conditions. Dimmable energy saving lamps ESL up to 100 watt. Automatic detection of load R+L or R+C. ESL is manually settable.Supply voltage and switching voltage 230V.

With integrated switching-off relay for the mains disconnection of switched circuits. The control push-button(s) of the room are connected via low voltage control wires to the terminals T1 and T2 of the EUD12F (field-free internal DC voltage). The permanent power supply must be connected directly to a phase conductor ahead of the mains disconnection relay FR12-230 V. Due to this, the complete function remains but the leads to the lamps is disconnected by means of the switching-off relay. A glow lamp current is not permitted.

Zero passage switching with soft start and soft OFF to protect lamps.The minimum brightness level (completely dimmed down) can be adjusted with the rotary switch % , e.g. for dimmable energy saving lamps.

The dimming speed can be adjusted with the dimming speed rotary switch. Simultaneously the soft on and soft off period is changed.

The settings ESL consider the special conditions regarding dimmable energy saving lamps:The starting operation is optimized and the dimm speed changes logarithmically. In these settings the special switching operation for children’s rooms is not possible and no wound (inductive) transformer must be dimmed. In position -ESL Memory is switched off. This can be of advantage for energy saving lamps because cold energy saving lamps require a higher minimum brightness as it will possibly be stored in Memory for warmer energy saving lamps.

Short-time control commands switch on/off, permanent control varies the brightness to the maximum level.

An interruption of control changes the direction of dimming. The setting of the brightness level is stored after switching off.

In case of a power failure the switching position and the brightness level are stored. If applicable the dimmer will be switched on at the stored brightness level after the supply voltage is recovered.

Automatic electronic overload protection and over-temperature switch-off.

With special switching operation for children's rooms: If the light is switched on by holdingdown the push-button, it starts at the lowest brightness level after approx. 1 second withoutmodifying the last stored brightness level.

Snooze function: With a double impulse the lighting is dimmed down from the current dimming position to the minimum brightness level and switched off. The current dimming position as well as the adjustable minimum brightness level determine the dimming time (max. = 60 minutes) which can be reduced as required. It can be switched off at any time by short-time control commands during the lighting is dimmed down. Holding down the push-button during the dimming down process dims up and stops the snooze function.

Mixing of L loads (inductive loads, e.g. wound transformers) and C loads (capacitive loads, e.g. electronic transformers) is not permitted. R loads (ohmic loads, e.g. 230V incandescentlamps and halogen lamps) may be added anytime.

Mixing of L loads and C loads is possible with dimmer switches EUD12Z (description page B2) and EUD12M (page B3) in connection with capacity enhancer LUD12 (page B5).

Available 50/2008.

Universal dimmer switch EUD12F for mains disconnection switching

EUD12F

Technical data page B12. Housing for operating instructions GBA12 page Z2.

B4

EUD12F Power MOSFET 300 W and switching-off relay

EAN 4010312 108086 65,10 €/pc.

Recommended retail prices excluding VAT.

Typical connection

max

. 300

W

Function rotary switch

Standard setting ex factory.

Page 23: Catalogo_Eltako_2009_ing

Power MOSFET 500 W. Standby loss 0.1 watt only.Modular device for DIN EN 50022 rail mounting.1 module = 18 mm wide, 58 mm deep.

Capacity enhancers LUD12-230V can be connected to the dimmer switches EUD12Z, EUD12M and SUD12 1-10V input. By this the switching capacity for one lamp will be increased according to the table by 500, 350 or 300 W or alternatively for additional lamps by 500 W per each capacity enhancer. When energy saving lamps ESL are used only suitable with ad-ditional lamps since the limit of 100W per lamp may not be exceeded.

Both switching modes for increase of capacity can be executed simultaneously.

Automatic detection of load R+L or R+C in the circuit "Increase of capacity with additional lamps".

Supply voltage 230 V.

Automatic electronic overload protection and over-temperature switch-off.

In the mode "Increase of capacity with additional lamps" the kind of load of a capacity enhancer LUD12-230 V can vary from the kind of load of the universal impulse dimmer switch.Therefore it is possible to mix L loads and C loads.

LUD12-230V

Multifunktions-Stromstoß-Schaltrelais* ESR12M

Function rotary switch

Capacity enhancer LUD12 for universal dimmer switches EUD12Z and EUD12M

Table of increase of capacity for one lamp ( ), not ESL

1st LUD12 + 500 W2nd-5th LUD12 + 350 W each6th- 9th LUD12 + 300 W each

Max. capacity in total 3600 W.

Technical data page B12. Housing for operating instructions GBA12 page Z2.

Switching modeincrease of capacity with additional lamps ( )

Maximal capacity of each additional lamp 500 W.

Switching modeIncrease of capacity for one lampe ( )

B5

Standard setting ex factory.

The switching mode "one lamp"( ) or "additional lamps"( ) is set with a rotary switch on the front.

This setting must be same as the actual installation, otherwise there is a risk of destruction of the electronics.

to furtherLUD12

to furtherLUD12

LUD12-230V Power MOSFET 500W EAN 4010312 107867 62,20 €/pc.

Recommended retail prices excluding VAT.

Page 24: Catalogo_Eltako_2009_ing

B6

1-10V control dimmer switch for electronic ballast units SDS12/1-10V

1 NO contact not potential free 600VA and 1-10V control output 40mA. Only 1 watt standby loss. With adjustable minimum brightness and dimming speed. With switching operation for children‘s rooms and snooze function. Modular device for DIN-EN 50 022 rail mounting. 1 modul = 18mm wide, 58mm deep.

Universal control voltage 8 to 230V UC, local and central on/off with same potential. Supply voltage 230V electrically isolated.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control.

Zero passage switching with soft ON and soft OFF to protect lamps.The brightness level is stored on switch-off (memory).

In case of a power failure the switch position and the brightness stage are stored and may be switched on when the power supply is restored.

The minimum brightness (fully dimmed) is adjustable with the % rotary switch. The dimming speed is adjustable using the dimming speed rotary switch. The load is switched on and off by a bistable relay at output EVG (electronic ballast units). Switching capacity for fluorescent lamps or LV halogen lamps with electronic ballast units 600VA.

By using a bistable relay coil power loss and heating is avoided even in the on mode. After installation, wait for automatic synchronisation before the switched consumer is connected to the mains.

Either direction switches can be connected to or these terminals are bridged and a pushbutton is connected as universal switch.As direction switch is "switch on and dim up" and is "switch off and dim down". A double click at triggers the automatic updimming until full brightness with dim speed. A double click at triggers the snooze function. The children‘s room function is realized with the pushbutton at .

As a universal switch, change the direction by briefly releasing the pushbutton.

Switching operation for children‘s rooms (universal switch or direction switch ): If the light is switched on by holding down the push-button, it starts at the lowest brightness level after approx. 1 second without modifying the last stored brightness level.

Snooze function (universal switch or direction switch ): With a double impulse the lighting is dimmed down from the current dimming position to the minimum brightness level and switched off. The current dimming position as well as the adjustable minimum brightness level determine the dimming time (max. = 60 minutes) which can be reduced as required. It can be switched off at any time by short-time control commands during the lighting is dimmed down. Holding down the push-button during the dimming down process dims up and stops the snooze function.

SDS12/1-10V

1 NO contact 600VASDS12/1-10V EAN 4010312 109403 50,80 €/pc.

Recommended retail prices excluding VAT.

Function rotary switches

Standard setting ex factory.

Typical connection

Technical data and typical circuit page B12.

Page 25: Catalogo_Eltako_2009_ing

Multifunktions-Stromstoß-Schaltrelais* ESR12M1-10V controller SUD12 for universal dimmer switches

1 NO contact potential free 600VA and 1-10V control output 40mA. Standby loss 0,9 Watt only.Modular device for DIN-EN 50 022 rail mounting. 1 module =18 mm wide, 58mm deep.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays.

The controller SUD12 can be used in two different modes:

SUD12/1-10V

Technical data page B12.

1 NO contact 600VASUD12/1-10V EAN 4010312 108116 50,80 €/pc.

1-10V output 1-10V input

Recommended retail prices excluding VAT.

In this mode the output of a 1-10V controller can be converted at A1/0 into a direct dimming function when connected to a capacity enhancer LUD12 at terminals X1/X2. The closing operation and the opening operation is also carried out externally at L of the SUD12.The rotary switch of the LUD12 must be adjusted to the setting (additional lamps).

Further capacity enhancers LUD12 in the mode "increase of capacity with additional lamps" can be connected to the controller SUD12 as described on page B5.A 100K potentiometer for brightness control may also be directly connected to the control input A1/0. If the input A1/0 is disconnected the LUD12 dimms to maximum brightness.

In this mode electronic ballast units and transformers with a 1-10V interface up to a total control current of 40mA can be controlled when connected to an universal dimmer switch EUD12Z or EUD12M.The EUD12Z or the EUD12M is controlled with pushbuttons at the universal control voltage input locally or centrally. The SUD12 converts the dimmer signals from Y1/Y2 to the 1-10V output 0/Q1 for the interface.It switches the electronic ballast with a bistable relay at the output EVG (electronic ballast units). Zero passage switching to protect contacts. The switching capacity for fluorescent lamps or low voltage halogen lamps with electronic ballast is up to 600VA. By using a bistable relay coil power loss and heating is avoided even in the on mode. The switched load may not be connected to the mains before the short automatic synchronisation after installation has terminated.At the same time a dircectly dimmable lamp can be connected to the dimmer switch EUD12. Furthermore the dimmer switch EUD12 can be expanded with capacity enhancers LUD12 for directly dimmable lamps as described on page B5.

B7

Page 26: Catalogo_Eltako_2009_ing

B8

Without N connection, POWER MOSFET 500W. Standby loss 0.7 watt only.With control inputs for push-button light switches and light switches.Built-in device for installation and surface mounting. 45 mm long, 55 mm wide, 18 mm deep.Universal dimmer switch for R, L and C loads up to 500 watt, depending on ventilation conditions. Automatic detection of load R+L or R+C.

Energy saving lamps ESL cannot be controlled by the dimmer type EUD61NP-230V (without N-connection).

Control voltage 230 V. Min. load 20 W only.

Zero passage switching with soft start and soft OFF to protect lamps.The minimum brightness level (completely dimmed down) can be adjusted with the rotary switch % . The dimming speed can be adjusted with the dimming speed rotary switch. Simultaneously the soft on and soft off period is changed.

Short-time control commands switch on/off, permanent control varies the brightness up to the maximum level. A short interruption of control changes the direction of dimming.

The brightness level is stored after switching off.

The system is disconnected in a definite sequence in case of a power failure.

Automatic electronic overload protection and over-temperature switch-off.

If light switches cannot be replaced by push-button light switches, there is a separatecontrol input for light switches. If the switch is opened briefly after closing, the light is dimmeduntil the next time it is opened again briefly. The dimming direction changes automatically atboth peaks. The dimming direction can also be changed by opening the switch briefly twice.

Switching operation for children‘s rooms: If the light is switched on by holding down the push-button, it starts at the lowest brightness level after approx. 1 second without modifying the last stored brightness level.

Snooze function: With a double impulse the lighting is dimmed down from the current dimming position to the minimum brightness level and switched off. The current dimming position as well as the adjustable minimum brightness level determine the dimming time (max. = 60 minutes) which can be reduced as required. It can be switched off at any time by short-time control commands during the lighting is dimmed down. Holding down the push-button during the dimming down process dims up and stops the snooze function.

Without N connection, therefore suitable for mounting directly behind the push-button light switch or light switch, even if no N wire is available.

Universal dimmer switch EUD61NP without N connection

EUD61NP-230V

Typical connection

Control by push-button switches or light switches.

Function rotary switches

Standard setting ex factory.

Technical data page B12.

EUD61NP-230V Power MOSFET 500 W EAN 4010312 108062 51,80 €/pc.

Recommended retail prices excluding VAT.

Page 27: Catalogo_Eltako_2009_ing

B9

Universal dimmer switch EUD61NPN

Power MOSFET 500W. Standby loss 0.1 watt only.For installation and surface mounting. 45mm long, 55mm wide, 18mm deep.Universal dimmer switch for R, L and C loads up to 300 watt, depending on ventilation conditions. Dimmable energy saving lamps ESL up to 100 watt. Automatic detection of load R+L or R+C. ESL is manually settable.

Universal control voltage 8 to 230V UC, electrically isolated from the 230V supply voltage and switching voltage.

Zero passage switching with soft start and soft OFF to protect lamps.The minimum brightness level (completely dimmed down) can be adjusted with the rotary switch % , e.g. for dimmable energy saving lamps.

The dimming speed can be adjusted with the dimming speed rotary switch. Simultaneously the soft on and soft off period is changed.

The settings ESL consider the special conditions regarding dimmable energy saving lamps:The starting operation is optimized and the dimm speed changes logarithmically. In these settings the special switching operation for children’s rooms is not possible and no wound (inductive) transformer must be dimmed. In position -ESL Memory is switched off. This can be of advantage for energy saving lamps because cold energy saving lamps require a higher minimum brightness as it will possibly be stored in Memory for warmer energy saving lamps.

Short-time control commands switch on/off, permanent control varies the brightness up to the maximum level.

An interruption of control changes the direction of dimming. The brightness level is stored after switching off.

In case of a power failure the switching position and the brightness level are stored. If applicable the dimmer will be switched on at the stored brightness level after the supply voltage is recovered.

Automatic electronic overload protection and over-temperature switch-off.

Switching operation for children‘s rooms: If the light is switched on by holding down the push-button, it starts at the lowest brightness level after approx. 1 second without modifying the last stored brightness level.

Snooze function: With a double impulse the lighting is dimmed down from the current dimming position to the minimum brightness level and switched off. The current dimming position as well as the adjustable minimum brightness level determine the dimming time (max. = 60 minutes) which can be reduced as required. It can be switched off at any time by short-time control commands during the lighting is dimmed down. Holding down the push-button during the dimming down process dims up and stops the snooze function.

Mixing of L loads (inductive loads, e.g. wound transformers) and C loads (capacitive loads, e.g. electronic transformers) is not permitted. R loads (ohmic loads, e.g. 230V incandescent-lamps and halogen lamps) may be added anytime.

EUD61NPN-UC

EUD61NPN-UC Power MOSFET 500 W EAN 4010312 107874 54,30 €/pc.

Recommended retail prices excluding VAT.

Technical data page B12.

Typical connection

Function rotary switches

Standard setting ex factory.

Page 28: Catalogo_Eltako_2009_ing

B10

Power MOSFET 500W. Standby loss 0.1 watt only.Built-in device for installation and surface mounting. 45 mm long, 55 mm wide, 18 mm deep.Universal dimmer switch for R, L and C loads up to 500 watt, depending on ventilation conditions. Dimmable energy saving lamps ESL up to 100 watt. Automatic detection of load R+L or R+C. ESL is manually settable.

Universal control voltage input 8 to 230V UC, electrically isolated from the 230 V supply voltage and switching voltage.

The minimum brightness level (completely dimmed down) can be adjusted with the rotary switch % , e.g. for dimmable energy saving lamps.

The function rotary switch selects 7 different functions.

Zero passage switching with soft start and soft OFF to protect lamps.Short-time control commands switch on/off, permanent control varies the brightness to themaximum level.

A interruption of control changes the direction of dimming. The brightness level is stored after switching off in case the function memory is set.If the function on max is set, it always switches on at the maximum brightness level.

In case of a power failure the switching position and the brightness level are stored. If applicable the dimmer will be switched on at the stored brightness level after the supply voltage is recovered.

Automatic electronic overload protection and over-temperature switch-off.

Setting of function ESV same as "memory+soft on" with setting of a release delay up to 90 minutes with the rotary switch % if the manual off command is not given. Before time-out switch-off early warning function by dimming down within 1 minute.

The settings ESL consider the special conditions regarding dimmable energy saving lamps:The starting operation is optimized and the dimm speed changes logarithmically. In these settings the special switching operation for children’s rooms is not possible and no wound (inductive) transformer must be dimmed. In position -ESL Memory is switched off. This can be of advantage for energy saving lamps because cold energy saving lamps require a higher minimum brightness as it will possibly be stored in Memory for warmer energy saving lamps.

Switching operation for children‘s rooms: If the light is switched on by holding down the push-button, it starts at the lowest brightness level after approx. 1 second without modifying the last stored brightness level.

Snooze function: With a double impulse the lighting is dimmed down from the current dimming position to the minimum brightness level and switched off. The current dimming position as well as the adjustable minimum brightness level determine the dimming time (max. = 60 minutes) which can be reduced as required. It can be switched off at any time by short-time control commands during the lighting is dimmed down. Holding down the push-button during the dimming down process dims up and stops the snooze function.

Available 02/2009

EUD61M-UC

Multifunktions-Stromstoß-Schaltrelais* ESR12MMultifunction universal dimmer switch EUD61M

Technical data page B12.

Typical connection

Function rotary switches

Standard setting ex factory.

EUD61M-UC Power MOSFET 500W EAN 4010312 107973 60,70 €/pc.

Recommended retail prices excluding VAT.

Page 29: Catalogo_Eltako_2009_ing

Typical circuits

B11

Typical circuit of a central control "central ON+OFF" with the dimmer switches EUD12Z-8..230V UC

Typical circuit for mains disconnection relay FR12 with dimmer switches and impulse switches

centraloff

centralon

localon/offdimming

localon/offdimming

localon/offdimming

to furtherdevices

monitored circuit

Page 30: Catalogo_Eltako_2009_ing

Technical data universal dimmer switches, capacity enhancers and 1-10V controllers

B12

Compliance with: EN 61000-6-3, EN 61000-6-1 and EN 60 669

EUD12NPN 1)

EUD12Z 1)

EUD12M1)

LUD12 1)

EUD61NPN 1)

EUD61M1)

EUD61NP1)

EUD12F 1) SDS12SUD12

Spacing of control connections/ load 6mm6mmEUD61NP: 3mm

6mm 6mm

Incandescent lamps 230V (R) up to 500 W up to 500 W up to 300 W −

Halogen lamps 230V (R) up to 500 W up to 500 W up to 300 W −

Inductive transformers (L) up to 500 W 2) 3) up to 500 W 2) 3) up to 300 W 2) 3) −

Electronic transformers (C) up to 500 W 2) 3) up to 500 W 2) 3) up to 300 W 2) 3) −

Dimmable energy saving lamps ESL 5) up to 100 W (not EUD12Z)

up to 100 W (not EUD61NP)

up to 100 W −

1-10VEVG*

− − −40 mA600VA

Terminal cross-section 2-fold/3-fold 12 mm2 / 7 mm2 M3 12 mm2 / 7 mm2 12 mm2 / 7 mm2

Maximum conductor cross-section 2-fold/3-fold 6 mm2 / 4 mm2 2,5 mm2 6 mm2 / 4 mm2 6 mm2 / 4 mm2

Screw headslotted/Phillips, pozidriv

slottedslotted/Phillips, pozidriv

slotted/Phillips, pozidriv

Shock-hazard protection (on the device) VDE 0106 part 100 VDE 0106 part 100 VDE 0106 part 100 VDE 0106 part 100

Time on 100% 100% 100% 100%

Max./min. temperature at mounting location +50°C/-20°C 4) +50°C/-20°C 4) +50°C/-20°C 4) +50°C/-20°C

Standby loss (active power) 0,1W0,1WEUD61NP: 0,7W

0,1W 1W

Control voltage 8..230V UC8..230V UCEUD61NP: 230V

internal DC voltage 8..230V UC

Control current 230 V-control input − EUD61NP: 0,7mA − −

Control current universal control voltageall control voltages (< 5 s) 8/12/24/230 V (< 5 s)

10(100)mA2/3/7/4(100)mA

−− 3/5/10/4(100)mA

Control current central8/12/24/230 V (< 5 s)

3/5/10/4(100)mA − − 3/5/10/4(100)mA

Max. parallel capacitance (approx. length) of single control lead at 230 V AC

0,9μF (3000 m)0,9μF (3000 m)EUD61NP: 0,06μF (200 m)

− 0,3 μF (1000 m)

Max. parallel capacitance (approx. length) of central control lead at 230 V AC

0,9μF (3000 m) − − 0,3 μF (1000 m)

1) At a load of more than 300W (EUD12F: 110W) a ventilation clearance of 1/2 module to adjacent devices must be maintained. The switching capacity of the EUD61 depends also on the ventilation conditions.

2) Per dimmer or capacity enhancer it is only allowed to use max. 2 inductive (wound) transformers of the same type, furthermore no-load operation on the secondary part is not permitted. The dimmer might be destroyed. Therefore do not permit load breaking on the secondary part. Operation in parallel of inductive (wound) and capacative (electronic) transformers is not permitted!

3) When calculating the load a loss of 20% for inductive (wound) transformers and a loss of 5% for capacitive (electronic) transformers must be considered in addition to the lamp load.

4) Affects the max. switching capacity. 5) In the settings ESL no wound (inductive) transformer must be dimmed.

*EVG = electronic ballast units

Page 31: Catalogo_Eltako_2009_ing

Selection table switching relays, control relays and coupling relays C0Switching relay ER12DX C1Switching relay ER12 C2Impulse switch with integrated relay function ESR12NP C3Multifunction impulse switch with integrated relay function ESR12M C4Switching, control and coupling relays ER12 C5Switching relays and control relays ER12 and coupling relays KR09 C6Switching relay ER61 and Impulse switch with integrated relay function ESR61NP C7Switching relay ER61 and Multifunction impulse switch with integrated relay function ESR61M C8Isolating relay ETR61NP with window contact FK C9Technical data C10

Switc

hin

g a

nd

co

ntr

ol

pro

fess

ion

als

Switching on the future.

Electronic switching relays,control relays and coupling relays

C

Page 32: Catalogo_Eltako_2009_ing

Switching and control professionalsProfessional hybrid relays combine the advantages of nonwearing electronic control with high switching capacity of special relays. We also use mainly bistable relays. Thus preventing coil power loss even in the on mode. This increases energy effi ciency and reduces heating in the switch cabinet.

1) Glow lamp current independent from the ignition voltage. 2) Depends on the set function. 3) If the control voltage is 230 V, but the phase conductor is different from the 230 V supply voltage, the universal voltage control input must be used. 4) At the control input . 5) The relay contact can be open or closed when putting into operation. It will be synchronised at first operation. 6) The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated. 7) Duplex technology: When switching 230V/50Hz the contact switching takes place in the zero passage when L is connected to 1(L) and N to (N). The standby loss is then 0.1 Watt.

Selection table switching relays, control relays and coupling relays

C0

Page C1 C2 C2 C3 C4 C5 C5 C5 C6 C6 C7 C7 C8 C8 C9pi

ctog

ram

s

ER12

DX-

UC

ER12

-200

-8..2

30V

UC

ER12

-110

-8..2

30V

UC

ESR1

2N

P-8.

.230

V UC

ESR1

2M-8

..230

V UC

ER12

-001

-230

V

ER12

-002

-230

V

ER12

-001

-8..2

30V

UC

ER12

-002

-8..2

30V

UC

KR09

-12

V UC

, 24

V UC

, 230

V

ER61

-8..2

30V

UC

ESR6

1NP-

8..2

30V

UC

ER61

-230

V

ESR6

1M-8

..230

V UC

ETR6

1NP-

230

V

Modular device for mounting on DIN rail EN 50022, number of modules 18 mm each

1 1 1 1 1 1 1 1 1 ½

Built-in device for installation (e.g.fl ush-mounting box) and surface mounting

Number NO contacts or changeover contact (W) potential free (not potential free)

1 2 1 (1)1+1 2)

2 2) 1W 2W 1W 2W 1 1W (1) 1W1+1

2)

2 2) (1)

Number NC contacts potential free 1 1-22) 1 1-22)

Zero passage switching 7)

Switching capacity 16A/250V AC

Switching capacity 10A/250V AC 6A

Incandescent lamp load W 2000 2000 2000 2300 2000 2300 2000 2000 2000 500 2000 2000 2300 2000 2000

Bistable relay(s) as relay contact(s) 5) 5) 5) 6) 5) 5) 5) 6) 5)

Switchable between the functions forimpulse switches and switching relays

Universal control voltage

Additional control voltage 230 V

Supply voltage same as control voltage

Supply voltage 230 V 3)

No standby loss

Low standby loss

Glow lamp current (mA)at the control input 230 V 150 1) 50 1)4)

Page 33: Catalogo_Eltako_2009_ing

1 NO contact potential free 16A/250V AC, incandescent lamp load up to 2000W. No standby loss.Modular device for DIN-EN 50 022 rail mounting.1 module = 18 mm wide, 58 mm deep.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

* With the Eltako Duplex technology the normally potential-free contacts can still switch in zero passage when switching 230V AC 50Hz and therefore drastically reduce wear. Simply connect the neutral conductor to the terminal (N) and L to 1 (L) for this. This gives an additional standby consumption of only 0.1 Watt.If the contact is used for controlling switching devices which do not perform zero passage switching themselves, (N) should not be connected because the additional closing delay otherwise causes the opposite effect.

Universal control voltage 8 to 230 V UC.

Very low switching noise.

Contact position indicator with LED.

Same terminal connection as electromechanical switching relay R12-100-.

By using a bistable relay coil power loss and heating is avoided even in the on mode. The relay contact can be open or closed when putting into operation. It will be synchronised at first operation.

.

ER12DX-UC *

Switching relay ER12DX

C1

Technical data page C10.

ER12DX-UC 1 NO 16A EAN 4010312 205402 33,70 €/pc.

Recommended retail prices excluding VAT.

Typical connection

If N is connected, the zero passage switching is active.

Page 34: Catalogo_Eltako_2009_ing

C2

Switching relay ER12

2 NO contacts potential free 16A/250V AC, incandescent lamp load up to 2000W. No standby loss.Modular device for DIN-EN 50 022 rail mounting.1 module = 18 mm wide, 58 mm deep.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

Universal control voltage 8 to 230 V UC.

Very low switching noise.

Contact position indicator with LED.

Maximum current across both contacts 20A for 230V.

Same terminal connection as electromechanical switching relay R12-200-.

By using a bistable relay coil power loss and heating is avoided even in the on mode.The relay contact can be open or closed when putting into operation. It will be synchronised at first operation.

ER12-200-8..230V UC

Technical data page C10.

38,00 €/pc.2 N0 16A ER12-200-8..230V UC EAN 4010312 205433

1 NO + 1 NC contact potential free 16A/250V AC, incandescent lamp load up to 2000W. No standby loss.Modular device for DIN-EN 50 022 rail mounting.1 module = 18 mm wide, 58 mm deep.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

Universal control voltage 8 to 230 V UC.

Very low switching noise.

Contact position indicator with LED.

Same terminal connection as electromechanical switching relay R12-110-.

By using a bistable relay coil power loss and heating is avoided even in the on mode.The relay contact can be open or closed when putting into operation. It will be synchronised at first operation.

Technical data page C10.

ER12-110-8..230V UC

ER12-110-8..230V UC 1 NO + 1 NC 16 A EAN 4010312 205440 38,00 €/pc.

Recommended retail prices excluding VAT.

Page 35: Catalogo_Eltako_2009_ing

Impulse switch with integrated relay function* ESR12NP

1 NO contact not potential free 16A/250V AC, incandescent lamp load up to 2300W. Off delay impulse switch with switch-off early warning and push-button permanent light switchable. Standby loss 0.5 watt only.Modular device for DIN-EN 50 022 rail mounting.1 module = 18 mm wide, 58 mm deep.

Zero passage switching to protect contacts and lamps. This prolongs in particular the lifetimeof energy saving lamps.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

Control voltage 230 V. In addition electrically isolated universal voltage from 8 to 230 V UC.Supply voltage and switching voltage 230 V.

Very low switching noise. If the function ESV is set, defi nitely variable off-delay time RV from 2 to 120 minutes, settable by minute scale.

Contact position indication with two LEDs. This starts blinking in case of a blocked push-button(not if the function ER is set).

Glow lamp current up to 150 mA only at the control input 230 V independent from ignition voltage (not if the function ER is set).

In case of a power failure the system is disconnected in a preset sequence.

The functions ES, ESV or ER are selectable by means of a rotary switch.

ES = Impulse switch

ER = Switching relay

ESV = Impulse switch with off delay. The impulse switch automatically disconnects after the set delay is timed out if a manual OFF command has not been given. Infi nitely variable time range up to120 minutes.

ESV = If switch-off early warning is set the stairwell lighting starts fl ickering approximately+ 30 seconds before timeout at repeated shorter time intervals. During this process reset is possible.

ESV = If push-button permanent light is set permanent light can be switched on by+ pressing longer than 1 sec. This switches off automatically after 2 hours or by an operation longer than 2 seconds.

ESV If both switch-off early warning function and permanent light by push-button are+ set, the switch-off early warning function is activated before switching off the permanent light.

This electronic impulse switch does not need a base load for switching lights in rooms which are monitored by a FR12-230V mains disconnection relay.

* This describes our devices wich can be used as impulse switches as well as switching relays. This halves the number of types and increases the stock turnover.

ESR12NP-230V+8..230V UC

Function rotary switches

Standard setting ex factory.

Technical data page C10. Housing for operating instructions GBA12 page Z2.

= switch-off early warning

= push-button permanent light

= switch-off early warning and push-button

permanent light

Typical connection

ESR12NP-230V+8..230V UC 1 N0 16A EAN 4010312 107928 37,20 €/pc.

Recommended retail prices excluding VAT.

C3

Page 36: Catalogo_Eltako_2009_ing

Multifunktions-Stromstoß-Schaltrelais* ESR12MMultifunction impulse switch with integrated relay function * ESR12M

1 +1 NO contacts potential free 16A/250V AC, incandescent lamp load up to 2000W. Standby loss 0.5 watt only.Modular device for DIN-EN 50 022 rail mounting.1 module = 18 mm wide, 58 mm deep.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

Universal control voltage 8 to 230 V UC. Supply voltage is same as the control voltage

Contact position indication with two LEDs. Very low switching noise.

By using bistable relays coil power loss and heating is avoided even in the on mode. The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated.

In case of a power failure the system is disconnected in a preset sequence.

From 110 V control voltage and in switching positions 2S, WS, SS and GS glow lamp currentup to 50 mA.

The functions of the big rotary switch are preselected using the small rotary switch ES/ER.The setting ER selects the function in brackets. 18 different functions are selectable using the big rotary switch: OFF = Permanent OFF

2xS = 2-fold impulse switch with 1 NO contact each, control inputs A1 and A3 (2xR) = 2-fold switching relay with 1 NO contact each, control inputs A1 and A3

2S = Impulse switch with 2 NO contacts (2R) = Switching relay with 2 NO contacts

WS = Impulse switch with 1 NO contact and 1 NC contact (WR) = Switching relay with 1 NO contact and 1 NC contact

SS1 = Impulse multi circuit switch 1 + 1 NO contacts for switching sequence 1 (RR) = Switching relay (closed-circuit current relay) with 2 NC contacts

SS2 = Impulse multi circuit switch 1 + 1 NO contacts for switching sequence 2 (EAW) = Impulse relay for fleeting NO contact and fleeting NC contact with 1 + 1 NO contacts, wiping time 1 sec each

SS3 = Impulse multi circuit switch 1 + 1 NO contacts for switching sequence 3 (EW) = Impulse relay for fleeting NO contact with 1 NO contact and 1 NC contact, wiping time 1 sec

GS = Impulse group switch 1 + 1 NO contacts (AW) = Impulse relay fleeting NC contact with 1 NO contact and 1 NC contact, wiping time 1 sec

RS = Switch with A1= set control input and A3 = reset control input (GR) = Group relay 1 + 1 NO contacts

ON = Permanent ON

Switching sequence SS1: 0 - contact 1 (1-2) - contact 2 (3-4) - contacts 1 + 2Switching sequence SS2: 0 - contact 1 - contacts 1 + 2 - contact 2Switching sequence SS3: 0 - contact 1 - contacts 1 + 2Switching sequence GS: 0 - contact 1 - 0 - contact 2GR: Relay with alternating closing contacts

The control inputs A1 and A3 have the same functions except for 2xS, 2xR and RS.

* This describes our devices wich can be used as impulse switches as well as switching relays. This halves the number of types and increases the stock turnover.

ESR12M-8..230V UC

Function rotary switches

Standard setting ex factory.

Typical connection

Technical data page C10. Housing for operating instructions GBA12 page Z2.

8-230 V UC

ESR12M-8..230V UC 1+1 N0 16A EAN 4010312 107935 51,00 €/pc.

Recommended retail prices excluding VAT.

check-backsignal

C4

Page 37: Catalogo_Eltako_2009_ing

1 change over contact potential free 16A/250V AC, incandescent lamp load up to 2000W. No standby loss.Modular device for DIN-EN 50 022 rail mounting.1 module = 18 mm wide, 58 mm deep.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

Universal control voltage 8 to 230V UC.Low control power demand, therefore substantially less heat is generated.

Integrated free-wheeling anti-surge diode (A1= +, A2= -).Safe disconnection to VDE 0106, Part 101; therefore, these devices can also be used ascoupling relays.By using a bistable relay coil power loss and heating is avoided even in the on mode. The relay contact can be open or closed when putting into operation. It will be synchronised at first operation.

1 change over contact potential free 16A/250V AC, incandescent lamp load up to 2300W. No standby loss.Modular device for DIN-EN 50 022 rail mounting.1 module = 18 mm wide, 58 mm deep.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

Control voltage 230V.

Low control power demand, therefore substantially less heat is generated.

Low switching noise. Contact position indicator with LED.

Integrated free-wheeling anti-surge diode (A1= +, A2= -).

Safe disconnection to VDE 0106, Part 101; therefore, these devices can also be used ascoupling relays.

Switching, control and coupling relays ER12

ER12-001-230 V

Technical data page C10.

2 change over contacts potential free 10 A/250V AC, incandescent lamp load up to 2000 W. No standby loss.Modular device for DIN-EN 50 022 rail mounting.1 module = 18 mm wide, 58 mm deep.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

Control voltage 230V.

Low control power demand, therefore substantially less heat is generated.

Low switching noise. Contact position indicator with LED.

Integrated free-wheeling anti-surge diode (A1= +, A2= -).

ER12-002-230 V

ER12-001-8..230 V UC

Technical data page C10.

Technical data page C10.

ER12-001-230V 1 CO 16 A EAN 4010312 200032 28,40 €/pc.

2 CO 10 AER12-002-230V EAN 4010312 200063 36,00 €/pc.

ER12-001-8..230V UC 1 CO 16 A EAN 4010312 205365 36,30 €/pc.

Recommended retail prices excluding VAT.

C5

Page 38: Catalogo_Eltako_2009_ing

Multifunktions-Stromstoß-Schaltrelais* ESR12MSwitching relays and control relays ER12Coupling relays KR09

2 change over contacts potential free 16A/250V AC, incandescent lamp load up to 2000W. No standby loss.Modular device for DIN-EN 50 022 rail mounting.1 module = 18 mm wide, 58 mm deep.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

Low switching noise. Contact position indicator with LED.

Integrated free-wheeling anti-surge diode (A1= +, A2= -).

By using a bistable relay coil power loss and heating is avoided even in the on mode.The relay contact can be open or closed when putting into operation. It will be synchronised at first operation.

ER12-002-8..230 V UC

1 NO contact potential free 6A/250V AC, incandescent lamp load up to 500W. No standby loss.Modular devices for DIN-EN 50 022 rail mounting.1/2 module = 9 mm wide, 55 mm deep.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

Control voltages 12V UC, 24V UC or 230V.

Contact position indicator with LED. Control power demand 0.2 W only.

Safe disconnection to VDE 0106, Part 101; therefore, these devices can also be used ascoupling relays.

KR09-12V UC, KR09-24V UC and KR09-230V

Technical data page C10.

Technical data page C10.

ER12-002-8..230V UC 2 CO 16 A EAN 4010312 205372 44,20 €/pc.

1 N0 6A

1 N0 6A

1 N0 6A

KR09-12V UC

KR09-24V UC

KR09-230V

EAN 4010312 203415

EAN 4010312 203385

EAN 4010312 203378

29,20 €/pc.

29,20 €/pc.

30,10 €/pc.

Recommended retail prices excluding VAT.

C6

Page 39: Catalogo_Eltako_2009_ing

C7

1 NO contact not potential free 10A/250V AC, incandescent lamp load up to 2000W. Off delay impulse switch with switch-off early warning and push-button permanent light switchable. Standby loss 0.5 watt only.For installation and surface mounting. 45 mm long, 55 mm wide, 18 mm deep.

Zero passage switching to protect contacts and lamps. This prolongs in particular the lifetimeof energy saving lamps.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

By using a bistable relay coil power loss and heating is avoided even in the on mode. The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated.

Control voltage 230 V. In addition electrically isolated universal control voltage from 8 to 230 V UC. Supply voltage and switching voltage 230 V.

Very low switching noise. Variable time range up to 120 minutes in the function ESV.

At the control input push-buttons with a glow lamp current up to 50 mA can be connected.If the timing period is set to minimum in the function ESV, the release delay is switched off.The standard impulse switch function ES is then set.

The function ER is selectable. If the function ER is selected a glow lamp current is not permitted. Only the control input A1- A2 should be used.

If switch-off early warning function is switched on, the light starts flickering approx. 30 seconds before time-out. This is repeated three times at decreasing time intervals.

If the permanent light function is switched on, the function can be activated by pressing the push-button for longer than 1 second. This function switches off automatically after 2 hours or by pressing the push-button for longer than 2 seconds.

If both switch-off early warning function and permanent light by push-button are set,the switch-off early warning function is activated before switching off the permanent light.

* This describes our devices wich can be used as impulse switches as well as switching relays. This halves the number of types and increases the stock turnover.

Switching relays ER61, impulse switch with integrated relay function* ESR61NP

Technical data page C10.

1 change over contact potential free 10A/250V AC, incandescent lamp load up to 2000W. No standby loss.For installation and surface mounting. 45 mm long, 55 mm wide, 18 mm deep.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

Universal control voltage 8 to 230V UC.

Low switching noise.

By using a bistable relay coil power loss and heating is avoided even in the on mode.The relay contact can be open or closed when putting into operation. It will be synchronised at first operation.

ER61-8..230 V UC

Typical connection

Technical data page C10.

ESR61NP-8..230 V UC

Typical connection

Side view

Function rotary switches

Standard setting ex factory.

Recommended retail prices excluding VAT.

ER61-8..230V UC 1 CO 10 A EAN 4010312 205358 33,80 €/pc.

ESR61NP-8..230V UC 1 N0 10A EAN 4010312 107911 39,20 €/pc.

Page 40: Catalogo_Eltako_2009_ing

1+1 NO contacts potential free 10A/250V AC. Incandescent lamp load up to 2000W. No standby loss.For installation and surface mounting. 45 mm long, 55 mm wide, 32 mm deep.State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

Universal control voltage 8 to 230V UC.

No permanent power supply necessary, therefore no standby loss.By using bistable relays coil power loss and heating is avoided even in the on mode.The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated.

The functions of the second rotary switch are preselected using the rotary switch ES/ER.The setting ER selects the function in brackets. 10 different functions are selectable.

2S = Impulse switch with 2 NO contacts (2R) = Switching relay with 2 NO contacts

WS = Impulse switch with 1 NO contact and 1 NC contact (WR) = Switching relay with 1 NO contact and 1 NC contact

SS1 = Impulse multi circuit switch 1 + 1 NO contacts for switching sequence 1 (RR) = Switching relay (closed-circuit current relay) with 2 NC contacts

SS2 = Impulse multi circuit switch 1 + 1 NO contacts for switching sequence 2 (EW) = Impulse relay for fleeting NO contact with 1 NO contact and 1 NC contact, wiping time 1 sec

GS = Impulse group switch 1 + 1 NO contacts (GR) = Group relay 1 + 1 NO contacts

Switching sequence SS1: 0 - contact 1(1-2) - contact 2 (3-4) - contacts 1 + 2Switching sequence SS2: 0 - contact 1 - contacts 1 + 2 - contact 2Switching sequence GS: 0 - contact 1 - 0 - contact 2GR: Relay with alternating closing contacts

* This describes our devices wich can be used as impulse switches as well as switching relays. This halves the number of types and increases the stock turnover.

ESR61M-8..230 V UC

Function rotary switches

Standard setting ex factory.

Typical connection

Switching relays ER61, multifunction impulse switch with integrated relay function* ESR61M

1 change over contact potential free 16A/250V AC. Incandescent lamp load up to 2300W. No standby loss.For installation and surface mounting. 45 mm long, 55 mm wide, 18 mm deep.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

Control voltage 230V.

Low control power demand, therefore substantially less heat is generated.

Low switching noise.

Integrated free-wheeling/anti-surge diode (A1= +, A2= -).

ER61-230 V

Technical data page C10.

Typical connection

Technical data page C10.

Side view

1 Wechsler 16 AER61-230V EAN 4010312 201152 27,00 €/pc.

1 + 1 N0 10 A EAN 4010312 108079 50,80 €/pc.ESR61M-8..230V UC

Recommended retail prices excluding VAT.

C8

Page 41: Catalogo_Eltako_2009_ing

Window contactThe window contact as described above is also supplied as individual (accessory) item.

Reed relay with 1 NO contact, switching capacity 5W or VA. Switching voltage max. 175V UC.

FK

Window contact FK

Reed relay and solenoid each 54x12x10mm

FK window contact EAN 4010312 903001 20,20 €/pc.

Isolating Relay ETR61NP with window contact FK

1 NO contact not potential free 10A/250V AC. With window contact.Standby loss 0.5 watt only.For installation and surface mounting. 45 mm long, 55 mm wide, 18 mm deep.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

Control input with internally produced low voltage 24V DC. With an isolating transformer electrically isolated from power supply and make contact (PELV).

Therefore no external low voltage power supply necessary.

With 2 L terminals and 2 N terminals for an easy and quick installation.

The enclosed window contact consists of a Reed relay with terminals and a solenoid. The NC contact opens when the solenoid approaches closer than 25mm. The disconnection relay ETR61NP is connected to terminals T1 and T2. Power supply to the extractor only cuts in when the window is open. ETR61NP can be wired in the flush mounted socket behind the socket for the extractor.

Power supply 230V.

Mounting the window contact FK:Lever out the inserts at the narrow end of the housing. Wire up the Reed relay and cut out the cable entry on the housing. Affix the two housings in parallel maximum 15mm apart and also screw if necessary. In the longitudinal direction the solenoid may be twisted in any direction compared to the Reed relay.

ETR61NP-230V+FK

Technical data page C10.

ETR61NP-230V 1 N0 10 A EAN 4010312 205488 47,00 €/pc.

Recommended retail prices excluding VAT.

C9Typical connection

The power supply of an extractor hood is connected by a window contact (NO if window open) so it can be switched on only if the window is open.

Window contact FK

Reed relay and solenoid each 54x12x10mm

Page 42: Catalogo_Eltako_2009_ing

Technical data electronic switching relays, control relays and coupling relays

Compliance with: EN 61000-6-3, EN 61000-6-1 and EN 60 669

Contacts

ESR12NP-230V+8..230 V UC a)

ESR12M-8..230 V UC b)

ER12DX-UC a)

ER12-200-8..230 V UC a)

ER12-110-8..230 V UC a)

ER12-001-8..230 V UC a)

ER12-002-8..230V UC a)

ER12-002-230VER61-8..230V UC a)

ESR61NP-8..230 V UC b)

ESR61M 8..230 V UC a)

ETR61NP-230 V

ER12-001-230VER61-230V

KR09-12 V UC,-24 V UC,-230 V

Contact material/contact gap AgSnO2 / 0,5 mm

Spacing of control connections/contact 3mm 6mm3mmETR61NP: 6mm

6mmER61: 3mm

6mm

Spacing of control connectionsC1-C2 or A1-A2/contact

6mm 6mm ESR61NP+M: 6mm -- --

Test voltage contact/contact–

ESR12M: 4000VER12-200/110: 2000V

ER12-002: 2000VESR61M: 2000V

– –

Test voltage control connections/contactTest voltage C1-C2 or A1-A2/contact

2000 V4000 V

4000V--

2000VESR61NP+M+ETR61NP: 4000V

4000 V–

4000 V–

Rated switching capacity 16 A/250 V AC 16 A/250 V AC 10 A/250 V AC 16 A/250 V AC 6A/250V AC

Incandescent lamp and halogen lamp load 1) 230 V

2300 W 2000 W 2000 W 2300W 500 W

Fluorescent lamp load with KVG* in lead-lag circuit or non compensated

1000 VA 1000 VA 1000 VA 1600 VA 600 VA

Fluorescent lamp load with KVG* shunt-compensated or with EVG*

500 VA 500 VA 500 VA 500 VA 300 VA

Compact fl uorescent lamps with EVG*and energy saving lamps ESL

15x7 W10x20 W

I on <_ 70A/ 10ms 2) 3)

I on <_ 70A/ 10ms 2)

ESR61NP: 15x7W,10x20W

I on <_ 70A/ 10ms 2) 52W

Max. switching current DC1: 12 V/24 V DC – 8 A not ESR: 8A 8 A 6 A

Life at rated load, cos = 1 or forincandescent lamps 1000 W at 100/h

> 10 5 > 10 5 > 10 5 > 10 5 > 10 5

Life at rated load,cos = 0.6 at 100/h

> 4 x104 > 4 x104 > 4 x104 > 4 x104 --

Max. operating cycles 103/h 103/h 103/h, ER12: 104/h 104/h 104/h

Contact position indication LED (not series 61)

Terminal cross-section 12 mm2, series 61: clamping screw M3

Maximum conductor cross-section 6 mm2, series 61: 2.5mm2

Screw head slotted/Phillips, pozidriv, series 61: slotted

Shock-hazard protection (on the device) VDE 0106 part 100

Electronics

Time on 100% 100% 100% 100% 100%

Max./min. temperature at mounting location +50°C/-20°C +50°C/-20°C +50°C/-20°C +50°C/-20°C +50°C/-20°C

Stand by loss (active power) 0.5 W only ESR12M: 0.5Wonly ESR61NP + ETR61NP: 0.5W

– –

Control current 230 V control input local ±20%

10 mA – 10 mA, ESR61M: – 10 mA –

Control current universal control voltageall control voltages mA ± 20%

– 4 (not ESR12M) ER12+ER61: 2, ESR61M:4 – –

Control current at 8/12/24/230V (<10s) mA ± 20%

2/4/9/5(100)only ESR12M: 0.1/0.1/0.2/1

only ESR61NP: 2/4/9/5(100)only ETR61NP: 10 mA/24V DC

– –/15/10/11

Max. parallel capacitance (approx. length) of control lead at 230 V AC

ES: 0,3μF (1000 m)ER: 3nF (10 m)C1-C2: 15nF (50 m)

0,5nF (2m)ESR12M: ES: 0,3μF (1000 m)ER: 0,06μF (200 m)ER12DX: 0,06μF (200 m)

0,06μF (200m)ESR61M: 0,5nF (2m)+ER61

0,06μF (200m)

0,06μF (200m)

a) Bistable relay as relay contact. The relay contact can be open or closed when putting into operation. It will be synchronised at fi rst operation. b) Bistable relay as relay contact. The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated. 1) For lamps with 150W max. 2) A 40-fold inrush current must be expected for electronic ballast devices. For steady loads of 1200W or 600W use the current-limiting relay SBR12 or SBR61. Product group G, page G3. 3) If zero passage switching is activated at the ER12DX: 15x7W rsp. 10x20W.

C10

*EVG = electronic ballast units; KVG = conventional ballast units

Page 43: Catalogo_Eltako_2009_ing

The

po

wer

ful p

rod

uct

lin

e

Selection table for staircase time switches and off-delay timers D0Staircase time switch TLZ12NP D1Multifunction Staircase time switch TLZ12M D2Staircase time switch TLZ12-8E D3Staircase time switch TLZ12-9E D4Staircase time switch TLZ61NP D5Off-delay timer NLZ12NP D6Off-delay timer NLZ61 and NLZ61NP D7Technical data D8

D

Staircase time switchesand off-delay timers

Switching on the future.

Page 44: Catalogo_Eltako_2009_ing

The powerful product lineState-of-the-art hybrid technology combines advantages of nonwearing electronic control with high switching

capacity of special relays.Up to 150 mA glow lamp current independent of the ignition voltage of the glow lamp at the staircase time switches.Double connections for push-button and lamp for type TLZ12NP-230V, so that the connection can be made as required

if there is a replacement by other staircase time switches: either two connections above and two below, or all four connections below.

Additional input for motion control for types TLZ12NP and TLZ12M.Zero passage switching to protect contacts and lamps. This extends in particular the product life of energy saving lamps.Switch-off early warning and permanent light by push-button switchable separately at the staircase time switches.TLZ12NP-230V and TLZ12M offer multifunction: the functions "impulse switch with off delay", "impulse switch" and "relay"

can be set. They also have a contact position indication with LED which starts blinking in case of a inhibited push-button.

1) As stipulated in DIN 18015-2, 1996-08, under 4.3.3 the following should be taken into account: For lighting systems in stairwells of multiple dwellings it is recommended to use staircase time switches with switch-off early warning function to prevent sudden darkness. If the switch-off early warning function is switched on the light starts fl ickering approx. 30 seconds before time-out and is repeated three times at decreasing time intervals. 2) Either two connections above and two below, or all four connections below. 3) Universal control voltage input opposed. 4) Time can be extended: Within the fi rst second after switching on or resetting the time can be extended by pressing the push-button repeatedly up to 5 times (incrementing). Each operation increments the set time once. 5) Up to 3600 W with capacity enhancer LUD12-230V. 6) Switch off early warning function through dimming. 7) The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated.

Selection table staircase time switches and off-delay timers

Page D1 D2 D3 D4 B3 D5 D5 D6 D7 D7

pict

ogra

ms

TLZ1

2NP-

230

V

TLZ1

2M-2

30V+

8..2

30V

UC

TLZ1

2-8E

-230

V+8.

.230

V UC

TLZ1

2-9E

-230

V

EUD1

2M-8

..230

V UC

if

the

func

tion

TLZ

is s

et

TLZ6

1NP-

230

V

TLZ6

1NP-

8..2

30V

UC

NLZ

12N

P-23

0V+

8..2

30V

UC

NLZ

61-2

30V

NLZ

61N

P-8.

.230

V UC

Modular device for mounting on DIN railEN 50022, number of modules 18 mm each

1 1 1 1 1 1

Built-in device for installation (e.g. fl ush-mounting box) and surface mounting

Incandescent lamp load W 2300 2300 2300 2300 500 5) 2000 2000 2300 2000 2000

Bistable relay as relay contact 7) 7) 7) 7)

Switch-off early warning function switchable 1) 6)

Electronics up to 12 minutes 20 min 9 min

Low standby loss

230 V control voltageUniversal control voltage (additionally)8 to 230 V UC

Glow lamp current in mA 150 150 50 50 5 50 50

Double connections push-button and lampConnections on 1 side 2) 3)

Automatic detection 3-/4-wire circuit3-wire circuit without attic lighting4-wire circuitResettable

Permanent light and switch-off logics with push-button switchable

Incrementing 4)

Separate switch for permanent lightAdditional input for motion control

With multifunction: TLZ, ESV, ES and ERwithout

ERwithout

ER

Zero passage switching

D0

Page 45: Catalogo_Eltako_2009_ing

1 NO contact not potential free 16 A/250 V AC. Incandescent lamps up to 2300W. Switch-off early warning and push-button permanent light switchable. Standby loss 0.5 watt only.Modular device for DIN EN 50022 rail mounting. 1 module = 18 mm wide, 58 mm deep.

Zero passage switching to protect contacts and lamps. This prolongs in particular the lifetimeof energy saving lamps.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh switching capacity of special relays.

230 V control voltage, supply voltage and switching voltage.

Extremely low switching noise. Precise variable time range from 1 to 12 minutes, settable by minute scale.

Contact position indicator with LED, which starts blinking after 15 minutes in case of aninhibited push-button (not if the function ER is set).

Glow lamp current up to 150 mA, independent of the ignition voltage of the glow lamps.

Own permanent light switch with the big rotary switch.

With input for motion control device BM, which converts the input signal into a control im-pulse if the function TLZ is set. In this case permanent light push-button not active.

3-wire and 4-wire circuits, resettable, with attic lighting if 4-wire circuit. Automatic detection of the method of connection.

After a power failure the lighting is switched on again in case the set time has not elapsed yet.

With double connections for push-button and lamp in order to connect either above or belowor only below.

If switch-off early warning function is switched on, the light starts fl ickering approx. 30 seconds before time-out and is repeated three times at decreasing time intervals.

If permanent light push-button is switched on, permanent light can be switched on by pressing the push-button longer than 1 second. This is switched off automatically after 60 minutes or by pressing the push-button longer than 2 seconds. This function is not available at the BM input.

If both switch-off early warning function and permanent light push-button are switched on, the switch-off early warning function is activated before the permanent light switches off.

If the function TLZ is selected the time can be extended within the fi rst second after switching on or resetting by pressing the push-button repeatedly up to fi ve times (incrementing). Each momentary-contact control increments the set time once. This function is not active at the BM input.

With multifunction: The following functions can be selected optionally: ES (impulse switch), ER (relay), ESV (impulse switch with release delay). If the function ESV is set the time rangeswhich can be set with the top rotary switch are as follows: 1=2 min, 2= 5 min, 3 =10 min, 4 =15 min, 5 =25 min, 6 = 35 min, 7= 45 min, 8 = 60 min, 10 = 90 min, 12=120 min. In this function the impulse switch automatically disconnects after the set delay is timed out, if a manual OFF command has not been given. Switch-off early warning and push-button permanent light can be switched on additionally in this position as well. Forgotten permanent light is switched off after 2 hours.

= Switch-off early warning function

= Push-button permanent light

= Switch-off early warning function and push-button permanent light

= Permanent light switched on (all click-stop positions)

AUTO = The set function is active (all click-stop positions)

TLZ12NP-230 V

Staircase time switch TLZ12NP

Typical connections

3-wire circuit, resettable

4-wire circuit with attic lighting, resettable

Technical data page D8. Housing for operating instructions GBA12 page Z2.

D1

Function rotary switches

TLZ12NP-230V EAN 4010312 400685 30,90 €/pc.1NO 16A

Recommended retail prices excluding VAT.

Page 46: Catalogo_Eltako_2009_ing

1 NO contact not potential free 16 A/250 V AC. Incandescent lamps up to 2300W. Switch-off early warning and push-button permanent light switchable. Standby loss 0.5 watt only.Modular device for DIN EN 50022 rail mounting. 1 module = 18 mm wide, 58 mm deep.Zero passage switching to protect contacts and lamps. This prolongs in particular the lifetimeof energy saving lamps.State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.230 V control voltage and additionally 8 to 230 V UC electrically isolated universal controlvoltage. 230 V supply voltage and switching voltage.Extremely low switching noise. Precise variable time range from 1 to 12 minutes, settable byminute scale.Contact position indication with LED, which starts blinking after 15 minutes in case of aninhibited push-button (not if the function ER is set).Glow lamp current up to 150 mA at the 230 V control input, independent from the ignition voltage.Own permanent light switch with the big rotary switch.With input for motion control device BM, which converts the input signal into a control im-pulse if the function TLZ is set. In this case permanent light push-button not active.3-wire and 4-wire circuits, resettable, with attic lighting if 4-wire circuit. Automatic detection of the method of connection.After a power failure the lighting is switched on again in case the set time has not elapsed yet.If switch-off early warning function is switched on, the light starts fl ickering approx. 30 seconds before time-out and is repeated three times at decreasing time intervals.

If permanent light push-button is switched on, permanent light can be switched on by pressing the push-button longer than 1 second. This is switched off automatically after 60 minutes or by pressing the push-button longer than 2 seconds. This function is not available at the BM input.

If both switch-off early warning function and permanent light push-button are switched on, the switch-off early warning function is activated before the permanent light switches off.If the function TLZ is selected the time can be extended within the fi rst second after switching on or resetting by pressing the push-button repeatedly up to fi ve times (incrementing). Each momentary-contact control increments the set time once. This function is not active at the BM input.With multifunction: The following functions can be selected optionally: ES (impulse switch), ER (relay), ESV (impulse switch with release delay). If the function ESV is set the time rangeswhich can be set with the top rotary switch are as follows: 1=2 min, 2= 5 min, 3 =10 min, 4 =15 min, 5 =25 min, 6 = 35 min, 7= 45 min, 8 = 60 min, 10 = 90 min, 12=120 min. In this function the impulse switch automatically disconnects after the set delay is timed out, if a manual OFF command has not been given. Switch-off early warning and push-button permanent light can be switched on additionally in this position as well. Forgotten permanent light is switched off after 2 hours.

= Switch-off early warning function

= Push-button permanent light

= Switch-off early warning function and push-button permanent light

= Permanent light switched on (all click-stop positions)

AUTO = The set function is active (all click-stop positions)

TLZ12M-230 V+8..230 V UC

Multifunction staircase time switch TLZ12M

Typical connections

4-wire circuit with attic lighting, resettable

3-wire circuit, resettable

+C1

Technical data page D8. Housing for operating instructions GBA12 page Z2.

Function rotary switches

D2

TLZ12M-230V+8..230V UC 1 NO 16A EAN 4010312 400128 41,30 €/pc.

Recommended retail prices excluding VAT.

Page 47: Catalogo_Eltako_2009_ing

1 NO contact not potential free 16 A/250 V AC. Incandescent lamps up to 2300 W. Switch-off early warning and push-button permanent light switchable. Standby loss 0.5 watt only.Modular device for DIN EN 50022 rail mounting. 1 module = 18 mm wide, 58 mm deep.

Zero passage switching to protect contacts and lamps. This prolongs in particular the lifetimeof energy saving lamps.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

230 V control voltage and additionally 8 to 230 V UC electrically isolated universal controlvoltage. 230 V supply voltage and switching voltage.

Glow lamp current up to 50 mA at the 230 V control input.

Precise variable time range from 1 to 12 minutes, settable by minute scale.

Own permanent light switch with the big rotary switch.

By using a bistable relay coil power loss and heating is avoided even in the on mode.The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated.

3-wire and 4-wire circuits, resettable, with attic lighting if 4-wire circuit. Automatic detection of the method of connection.

After a power failure the lighting is switched on again in case the set time has not elapsed yet.

If switch-off early warning function is switched on, the light starts fl ickering approx. 30 seconds before time-out and is repeated three times at decreasing time intervals.

If permanent light push-button is switched on, permanent light can be switched on by pressing the push-button longer than 1 second. This is switched off automatically after 60 minutes or by pressing the push-button longer than 2 seconds. This function is not available at the BM input.

If both switch-off early warning function and permanent light push-button are switched on, the switch-off early warning function is activated before the permanent light switches off.

The noiseless electronics is not even audible to a highly sensitive ear - unlike many synchronous motors with mechanical gearboxes.

= Switch-off early warning function

= Push-button permanent light

= Switch-off early warning function and push-button permanent light

= Permanent light switched on

AUTO = The set function is active

TLZ12-8E-230 V+8..230 V UC

Staircase time switch TLZ12-8E

4-wire circuit with attic lighting, resettable

Typical connections

3-wire circuit, resettable

Technical data page D8. Housing for operating instructions GBA12 page Z2.

D3

Function rotary switches

TLZ12-8E-230V+8..230V UC 1 NO 16A EAN 4010312 400746 35,30 €/pc.

Recommended retail prices excluding VAT.

Page 48: Catalogo_Eltako_2009_ing

1 NO contact not potential free 16 A/250 V AC. Incandescent lamps up to 2300W. Switch-off early warning switchable. Standby loss 0.5 watt only.Modular device for DIN EN 50022 rail mounting. 1 module = 18 mm wide, 58 mm deep.

Zero passage switching to protect contacts and lamps. This prolongs in particular the lifetimeof energy saving lamps.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

230 V control voltage, supply voltage and switching voltage.

Glow lamp current up to 50 mA.

Precise variable time range from 1 to 12 minutes, settable by minute scale.

Own permanent light switch with the big rotary switch.

3-wire circuit with attic lighting, not resettable.

After a power failure the lighting is switched on again in case the set time has not elapsed yet.

If switch-off early warning function is switched on, the light starts fl ickering approx. 30 seconds before time-out and is repeated three times at decreasing time intervals.

The noiseless electronics is not even audible to a highly sensitive ear - unlike many synchronous motors with mechanical gearboxes.

TLZ12-9E-230 V

Staircase time switch TLZ12-9E

Typical connection

3-wire circuit with attic lighting, not resettable

Function rotary switches

Technical data page D8.

= Switch-off early warning function

= Permanent light switched on (all click-stop positions)

AUTO = The set function is active (all click-stop positions)

D4

TLZ12-9E-230V 1 Schließer 16A EAN 4010312 400715 37,00 €/pc.

Recommended retail prices excluding VAT.

Page 49: Catalogo_Eltako_2009_ing

Staircase time switch TLZ61NP

D5

1 NO contact not potential free 10A/250V AC. Incandescent lamps up to 2000 W. Switch-off early warning and push-button permanent light switchable. Standby loss 0.5 watt only.Built-in device for installation and surface mounting. 45 mm long, 55 mm wide, 18 mm deep.Zero passage switching to protect contacts and lamps. This prolongs in particular the lifetimeof energy saving lamps.State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.By using a bistable relay coil power loss and heating is avoided even in the on mode.The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated.230 V control voltage, supply voltage and switching voltage. With infi nitely variable time range from 1 to 12 minutes. 50 mA glow lamp current. 3-wire and 4-wire circuits, resettable, with attic lighting if 4-wire circuit. Automatic detection of the method of connection.After a power failure the lighting is switched on again in case the set time has not elapsed yet.If switch-off early warning function is switched on, the light starts fl ickering approx. 30 seconds before time-out and is repeated three times at decreasing time intervals.If permanent light push-button is switched on, permanent light can be switched on by pressing the push-button longer than 1 second. This is switched off automatically after 60 minutes or by pressing the push-button longer than 2 seconds.If both switch-off early warning function and permanent light push-button are switched on, the switch-off early warning function is activated before the permanent light switches off.If the function TLZ is selected the time can be extended within the fi rst second after switching on or resetting by pressing the push-button repeatedly up to fi ve times (incrementing). Each momentary-contact control increments the set time once. The function ESV, impulse switch with release delay up to 120 minutes, can be selected optionally. If this function is set it is automatically disconnected after the set delay is timed out if a manual OFF command has not been given.If the timing period is set to minimum in the function ESV, the release delay is switched off. The standard impulse switch function ES is then set.

= Switch-off early warning function; = Push-button permanent light; = Switch-off early warning function and push-button permanent light

TLZ61NP-230 V

TLZ61NP-230V 1 NO 10A EAN 4010312 400791 37,90 €/pc.

1 NO contact not potential free 10A/250V AC. Incandescent lamps up to 2000 W. Switch-off early warning and push-button permanent light switchable. Standby loss 0.5 watt only.Built-in device for installation and surface mounting. 45 mm long, 55 mm wide, 18 mm deep.

230V control voltage and additionally 8 to 230V UC electrically isolated universal control voltage. 230V supply voltage and switching voltage.

Push-buttons with a glow lamp current up to 50mA can be connected to the control input .

All functions same as type TLZ61NP-230V.

TLZ61NP-8..230 V UC

TLZ61NP-8..230V UC 1 NO 10A EAN 4010312 400739 40,40 €/pc.

3-wire circuit, resettable

Typical connection

4-wire circuit with attic lighting, resettable

Function rotary switches

Typical connection

same as type TLZ61NP-230V, but with universal control voltage input +A1/-A2 additionallly

Function rotary switchessame as type TLZ61NP-230V

Technical data page D8.

Technical data page D8.

Recommended retail prices excluding VAT.

Page 50: Catalogo_Eltako_2009_ing

The fresh air professionalsFresh air in the bathroom with the professional off-delay timers NLZ, also known as off-delay relay. Accurate timing is self-evident for this electronic device as well as noiseless operation.The off-delay timers with universal voltage offer additional applications as here even different potentials for switch and fan can be applied.The NP types have a settable operate delay up to 12 minutes.

Off-delay timer NLZ12NP

1 NO contact not potential free 16 A/250 V AC.Standby loss 0.5 watt only.Modular device for DIN EN 50022 rail mounting. 1 module = 18 mm wide, 58 mm deep.

Zero passage switching to protect contacts and consumers.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

230 V control voltage and additionally 8 to 230 V UC electrically isolated universal control voltage. 230 V supply voltage and switching voltage.

Very low switching noise.

Off-delay time settable from 1 to 12 min with the top rotary switch. Operating delay settablefrom 0 to 12 minutes with the middle rotary switch. Permanent ON and permanent OFF with the bottom rotary switch.

Function: When the control contact (light switch) is closed the operate delay AV starts (if notset '0 minutes'), on time-out the fan is switched on. The set release delay RV (delay time) starts when the control contact opens and if a set operating delay has elapsed. The fan switches off on time-out.

This off-delay timer can be controlled by all dimmer switches EUD12 and EUD61 even in the minimum dimming position.

NLZ12NP-230 V+8..230 V UC

Function rotary switches

Technical data page D8.

RV = release delay (delay time)

AV = operating delay

D6

Typical connections

Fan control through light switch in case of different potentials onswitch and fan

Fan control through ultra lowvoltage door contact, light iscontrolled separately

Fan control through light switch

NLZ12NP-230V+8..230V UC 1 NO 16A EAN 4010312 602911 35,00 €/pc.

Recommended retail prices excluding VAT.

Page 51: Catalogo_Eltako_2009_ing

1 NO contact not potential free 10A/250V AC.Standby loss 0.5 watt only.Built-in device for installation and surface mounting. 45 mm long, 55 mm wide, 18 mm deep.

Zero passage switching to protect contacts and consumers.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

8 to 230 V UC universal control voltage. Supply voltage and switching voltage 230 V.

By using a bistable relay coil power loss and heating is avoided even in the on mode. The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated.

The top rotary switch varies the off-delay time from 1 to 12 minutes.

Operating delay settable from 0 to 12 minutes with the lower rotary switch.

Function: When the control contact (light switch) is closed the operatinh delay AV starts (if not set '0 minutes'), on time-out the fan is switched on. The set release delay RV (delay time) starts when the control contact opens and if a set operating delay has elapsed. The fan switches off on time-out.

This off-delay timer can be controlled by all dimmer switches EUD12 and EUD61 even in the minimum dimming position.

NLZ61NP-8..230 V UC

Off-delay timers NLZ61 and NLZ61NP

1 NO contact not potential free 10A/250V AC.Standby loss 0.4 watt only.Built-in device for installation and surface mounting. 45 mm long, 55 mm wide, 18 mm deep.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

The off-delay time is variable from 1 to 12 minutes.

230 V control voltage, switching voltage and supply voltage.

Function: When the control contact (light switch) is closed the load (fan) is started. The set release delay RV (delay time) starts when the control contact opens; the fan stops on time-out.

NLZ61-230V

Typical connections

Fan control through lightswitch

Function rotary switches

Technical data page D8.

Typical connection

Fan control through ultra lowvoltage door contact, light iscontrolled separately

Fan control through light switch in case of different potentials onswitch and fanTechnical data page D8.

RV = release delay (off-delay time)

AV = operating delay

D7

NLZ61-230V 1 NO 10A EAN 4010312 500095 35,90 €/pc.

NLZ61NP-8..230V UC 1 NO 10A EAN 4010312 603048 40,40 €/pc.

Recommended retail prices excluding VAT.

Page 52: Catalogo_Eltako_2009_ing

a) Bistabiles Relais als Arbeitskontakt. Der Relaiskontakt kann bei der Inbetriebnahme offen oder geschlossen sein und synchronisiert sich bei der erstenBetätigung. b) Bistabiles Relais als Arbeitskontakt. Nach der Installation die automatische Synchronisation abwarten, bevor der geschaltete Verbraucher andas Netz gelegt wird. 1) Bei Lampen mit max. 200 W. 2) Bei elektronischen Vorschaltgeräten ist mit einem bis zu 40-fachen Einschaltstrom zu rechnen.

b) Bistable relay as relay contact. The switched consumer may not be connected to the mains before the short automatic synchronisation after installation

has terminated. 1) Applies for lamps with max. 150 W. 2) A 40-fold inrush current must be expected for electronic ballast devices. For steady loads of 1200 W or 600 W use the current-limiting relay SBR12 or

SBR61. Product group G, page G3.

ContactsTLZ12NP/ TLZ12M /TLZ12-9E/NLZ12NP

TLZ12-8E b) TLZ61NP b)

NLZ61/ NLZ61NP b)

Contact material / contact gap AgSnO2/ 0.5 mm AgSnO2/ 0.5 mm AgSnO2/ 0.5 mm

Spacing of control connections /contactSpacing of control connections C1-C2 or A1-A2/contact

3 mm6 mm

3 mm6 mm

3 mm6 mm

Test voltage control connection / contactTest voltage C1-C2 or A1-A2/contact

2000 V4000 V

2000 V4000 V

2000 V4000 V

Rated switching capacity 16 A/250 V AC 16 A/250 V AC 10 A/250 V AC

Incandescent lamp and halogen lamp load 1) 230 V 2300 W 2300 W 2000 W

Fluorescent lamp load with KVG* in lead-lag circuit or non compensated

1000 VA 1000 VA 1000 VA

Fluorescent lamp load with KVG* shunt-compensated or with EVG*

500 VA 500 VA 500 VA

Compact fl uorescent lamps with EVG* and energy saving lamps ESL

15x 7 W10 x 20 W

15x 7 W10 x 20 W

I on 70 A/10 ms 2)

NP devices:15x 7 W, 10 x 20 W

Life at rated load, cos = 1 or for incandescent lamps 1000 W at 100/h

> 10 5 > 10 5 > 10 5

Life at rated load,cos = 0.6 at 100/h

> 4 x104 > 4 x104 > 4 x104

Max. operating cycles 103/h 103/h 103/h

Terminal cross-section 12 mm2 12 mm2 Clamping screw M3

Maximum conductor cross-section 6 mm2 6 mm2 2.5 mm2

Screw head slotted / Phillips, pozidriv slotted / Phillips, pozidriv slotted

Shock-hazard protection (on the device) VDE 0106 part 100 VDE 0106 part 100 –

Electronics

Time on 100% 100% 100%

Max./min. temperature at mounting location +50°C/-20°C +50°C/-20°C +50°C/-20°C

Standby loss (activ power) 0.5 W 0.5 W 0.4 W; NP: 0.5 W

Control current local at 230 V (<10 s) ± 20% 15 mA, NLZ12NP: 2 mA 5 (100) mATLZ61NP: 10mA,NLZ61: 0.1mA, NLZ61NP: –

Control current universal control voltage8/12/24/230 V (<10 s) ± 20%

2/4/9/5(100) mA 2/4/9/5(100) mA 2/4/9/5(100) mA

Max. parallel capacitance (approx. length) of individual control lead at 230 V AC

0.06 μF (200 m)C1/C2:0.9 μF (3000 m)

0.06 μF (200 m)C1/C2:0.9 μF (3000 m)

0.9 μF (3000 m)NP: 0.06 μF (200 m)A1-A2: 0.3 μF (1000 m)

Technical data staircase time switches and off-delay timers

Compliance with: EN 61000-6-3, EN 61000-6-1 and EN 60 669. With switch-off early warning function according to DIN18015-2.

D8

*EVG = electronic ballast units; KVG = conventional ballast units

Page 53: Catalogo_Eltako_2009_ing

Switching on the future.

The

succ

essf

ul

Selection table time relays and multifunction time relays E0Digital settable multifunction time relay MFZ12DDX E1Analogue settable multifunction time relay MFZ12 E2Analogue settable time relays EZ12 E3Analogue settable multifunction time relay MFZ12NP E4Analogue settable multifunction time relay MFZ61NP E5Description of functions E6Technical data E7

E

Time relays and multifunction time relaysfor universal control voltage

Page 54: Catalogo_Eltako_2009_ing

The successfulMultifunction time relays with up to 18 functions combined with universal control voltage 8 to 230V UC - a competitive advantage, particularly the digital settable time relays MFZ12DDX. Multifunction time relays NP with zero passage switching.

1) Up to 3600W with capacity enhancers LUD12-230V. 2) The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated. 3) Duplex technology: When switched with 230V/50Hz zero passsage switching is activated if L is connected to 15(L) and N to (N). Then additional standby loss of only 0.1 Watt.

Page E1 E2 E3 E3 E3 E3 B3 E4 E5

pict

ogra

ms

MFZ

12D

DX-

UC

MFZ

12-8

..230

V UC

EZ12

RV-8

..230

V UC

EZ12

AV-8

..230

V UC

EZ12

TI-8

..230

V UC

EZ12

EAW

-8..2

30V

UC

EUD

12M

-8..2

30V

UC

if th

e fu

nctio

n TI

is s

et

MFZ

12N

P-23

0V+

8..2

30V

UC

MFZ

61N

P-8.

.230

V UC

Modular device for mounting on DIN rail EN 50022, number of modules 18mm each

1 1 1 1 1 1 1 1

Built-in device for installation (e.g.fl ush-mounting box) and surfacemounting

Digital settable

Analogue settable

Number of NO contacts(not potential free) (1) (1) (1)

Number of CO contacts potential free 1 1 1 1 1 1

Zero passage switching 3)

Switching capacity 16A/250V AC

Switching capacity 10 A/250 V AC

Incandescent lamp load W 2000 2000 2000 2000 2000 2000 500 1) 2300 2000

Bistable relay as relay contact 2) 2) 2) 2) 2) 2) 2)

Universal control voltage

Low standby loss

Multifunction time relay

Off delay RV

Operate delay AV

Additive operate delay AV+

Fleeting NO contact EW EW

Fleeting NC contact AW

Fleeting NO contact and fl eeting NC contact EAW

Operate and release delay ARV

Additive operate and release delay ARV+

Relay function ER

Release-delay impulse switch SRV

Impulse switch functions ES and ESV

Clock generator starting with impulse TI

Clock generator starting with pause TP

Impulse controlled operate delay IA(e.g. automatic door opener)

Pulse shaper IF

Selection table time relays and multifunction time relays

E0

Page 55: Catalogo_Eltako_2009_ing

1 CO contact potential free 10A/250VAC. Incandescent lamps 2000W*. Standby loss 0.4 watt only.Modular device for DIN-EN 50 022 rail mounting. 1 module = 18mm wide, 58mm deep.

* With the Eltako Duplex technology the normally potential-free contacts can still switch in zero passage when switching 230V AC 50Hz and therefore drastically reduce wear. Simply connect the neutral conductor to the terminal (N) and L to 15 (L) for this. This gives an additional standby consumption of only 0.1 Watt.Universal control voltage 8 to 230V UC. Supply voltage same as the control voltage.

Both functions and times are entered at the touch of a key and indicated digitally on an LC display. Only two keys are required for this purpose.

When setting the time all values can be entered within preset time ranges (0.1 to 9.9 or 1 to 99 seconds, minutes or hours). The longest possible setting is 99 hours. 600 settings are possible. The time setting is continuously displayed digitally.

By using a bistable relay coil power loss and heating is avoided even in the on mode.The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated.

Functions (description page E6)RV = off delayAV = operate delayAV+ = operate delay additiveTI = clock generator starting with impulseTP = clock generator starting with pauseIA = impulse controlled pickup delay (e.g. automatic door opener)IF = pulse shaperEW = fleeting NO contactAW = fleeting NC contact

With TI, TP, IA, EAW, ARV and ARV+ functions, a different second time can be entered also withdifferent time ranges.

Setting the times and functions: The LCD component to be changed is selected by pressing the MODE key. The component accessed flashes. Press the SET key to change the component accessed. This may be the function, the time ranges, time T1 or time T2 (on TI, TP, IA, EAW, ARV and ARV+ only). Pressing the MODE key terminates each input. Once the time has been set with MODE, no more components are flashing. The timing relay is now ready to operate. Press the MODE key again to restart the input cycle. All the entered parameters are retained if they are not changed using SET. 25 sec. after the last operation and if the component still flashes the input cycle is automatically terminated and the previously made changes lapse.

Functions of the LC display: If the ON or OFF function was selected, no time is displayed, onlyON and OFF and a contact symbol in the correct position. On all other functions, the set time, the function code and the contact symbol are shown in the correct position (open or closed).The clock symbol flashes while the set time is elapsing and the remaining time is shown.

Safety in the event of a power failure: The set parameters are stored in an EEPROM and are therefore immediately available again when the power supply is restored after a power failure.

* The maximum load can be used starting at a delay time or clock cycle of 5 minutes. The maximum load will be reduced for shorter times as follows: up to 2 seconds 15%, up to 2 minutes 30%, up to 5 minutes 60%.

Digital settable multifunction time relay MFZ12DDX with 18 functions

MFZ12DDX-UC *

Technical data page E7. Housing for operating instructions GBA12 page Z2.

E1

MFZ12DDX-UC 1CO 10 A EAN 4010312 603079 59,60 €/pc.

Recommended retail prices excluding VAT.

8-230 V UC

Typical connection

If N is connected, the zero passage switching is active.

EAW = fleeting NO contact and fleeting NC contactARV = operate and release delayARV+ = operate and release delay additiveES = impulse switchSRV = release-delay impulse switchESV = impulse switch with release delay and switch-off early-warning functionER = relayON = permanent ONOFF = permanent OFF

Page 56: Catalogo_Eltako_2009_ing

1 CO contact potential free 10A/250V AC. Incandescent lamps 2000W*Standby loss 0.4 watt only.Modular device for DIN-EN 50 022 rail mounting.1 module = 18mm wide, 58mm deep.

Universal control voltage from 8 to 230V UC. Supply voltage same as control voltage.

Time setting between 0.1 second and 40 hours.

By using a bistable relay coil power loss and heating is avoided even in the on mode.The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated.

According to the connection of the power supply to the terminals B1 or B2 two differentlevels of settings can be selected:

Functions F with connection of the power supply to B1- A2 (description page E6)

RV = off delayAV = operate delayTI = clock generator starting with impulseTP = clock generator starting with pauseIA = impulse controlled operate delay (e.g. automatic door opener)EW = fleeting NO contactAW = fleeting NC contactARV = operate and release delayON = permanent ONOFF = permanent OFF

Functions (F) with connection of the power supply to B2-A2 (description page E6)

SRV = release-delay impulse switchER = relayEAW = fleeting NO contact and fleeting NC contactES = impulse switchIF = pulse shaperARV+ = additive operate and release delayESV = impulse switch with release delay and switch-off early-warning functionAV+ = additive operate delayON = permanent ONOFF = permanent OFF

The LED below the big rotary switch indicates the contact position while time-out is in progress. It blinks while the relay contact 15-18 is open (15-16 closed), and is continuously ON as long as the relay contact 15-18 is closed (15-16 open).

The time base T is selected by means of the middle, latching rotary switch T. Time-base figures available are 0.1 seconds, 0.5 seconds, 2 seconds, 5 seconds, 1 minute, 2 minutes, 5 minutes, 1 hour, 2 hours and 4 hours. The total time is obtained by multiplying the timebase by the multiplier.

The multiplier xT is set on the upper, latching rotary switch xT and is in the range from 1 to 10. Thus, time settings can be selected in the range from 0.1 second (time base 0.1 second and multiplier 1) and 40 hours (time base 4 hours and multiplier 10).

* The maximum load can be used starting at a delay time or clock cycle of 5 minutes. The maximum load will be reduced for shorter times as follows: up to 2 seconds 15%, up to 2 minutes 30%, up to 5 minutes 60%.

MFZ12-8..230 V UC

Analogue settable universal control voltage multifunction time relay MFZ12 with 18 settings

Technical data page E7. Housing for operating instructions GBA12 page Z2.

Function rotary switches

Typical connectionLevel of setting 2, Functions (F)

Typical connectionLevel of setting 1, Functions F

8-230 V UC

E2

8-230 V UC

MFZ12-8..230V UC 1 CO10 A EAN 4010312 602942 57,90 €/pc.

Recommended retail prices excluding VAT.

Page 57: Catalogo_Eltako_2009_ing

E3

Analogue settable time relays EZ12

1 CO contact potential free 10A/250V AC. Incandescent lamps 2000W*. Standby loss 0.4 watt only.Modular device for DIN EN 50022 rail mounting.1 module = 18mm wide, 58mm deep.

These digital settable time relays are identical to the MFZ12, except that they have one function only (description page E6).

On type EZ12TI T1 and T2 can be set separately by a second multiplier while the time base remains the same.On type EZ12EAW different functions can be selected by a rotary switch: fleeting NO contact(EW), fleeting NC contact (AW) or fleeting NO contact and fleeting NC contact (EAW).

Universal control voltage from 8 to 230V UC. Supply voltage like control voltage.

Time setting between 0.1 second and 40 hours.

By using a bistable relay coil power loss and heating is avoided even in the on mode.The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated.

The LED below the big rotary switch indicates the contact position while time-out is in progress. It blinks while the relay contact 15 -18 is open (15-16 closed), and is continuously ON as long as the relay contact 15-18 is closed (15-16 open).

The time base T is selected by means of the middle, latching rotary switch T. Time-basefigures available are 0.1 seconds, 0.5 seconds, 2 seconds, 5 seconds, 1 minute, 2 minutes,5 minutes, 1 hour, 2 hours and 4 hours. The total time is obtained by multiplying the timebase by the multiplier.

The multiplier xT is set on the upper, latching rotary switch xT and is in the range from 1 to 10. Thus, time settings can be selected in the range from 0.1 second (time base 0.1 second and multiplier 1) and 40 hours (time base 4 hours and multiplier 10).

* The maximum load can be used starting at a delay time or clock cycle of 5 minutes. The maximum load will be reduced for shorter times as follows: up to 2 seconds 15%, up to 2 minutes 30%, up to 5 minutes 60%.

EZ12RV/AV/TI/EAW-8..230 V UC

Typical connection

8-230 V UC

Function rotary switches

EZ12EAW

Function rotary switches

EZ12TI

Function rotary switches

EZ12RV /EZ12AV

Technical data page E7. Housing for operating instructions GBA12 page Z2.

RV release delay (OFF delay)

AV operate delay (ON delay)

TI clock generator starting with impulse (fl asher relay)

EW+AW+EAW fl eeting NO contact and fl eeting NC contact

EZ12RV-8..230V UC

EZ12AV-8..230V UC

EZ12TI-8..230V UC

EZ12EAW-8..230V UC

EAN 4010312 602973

EAN 4010312 602980

EAN 4010312 602997

EAN 4010312 603031

45,40 €/pc.

45,40 €/pc.

45,40 €/pc.

45,40 €/pc.

Recommended retail prices excluding VAT.

Page 58: Catalogo_Eltako_2009_ing

1 NO contact not potential free 16A/250V AC. Incandescent lamps 2300W*.Standby loss 0.5 watt only.Modular device for DIN EN 50022 rail mounting.1 module = 18mm wide, 58mm deep.

Zero passage switching to protect contacts and lamps. This prolongs in particular the lifetime of energy saving lamps.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays.

230V control voltage and additionally 8 to 230V UC electrically isolated universal control voltage. 230V supply voltage and switching voltage.

Very low switching noise.

Time settings between 0.1 seconds and 40 hours.

Functions F (description page E6)

RV = release delay

AV = operate delay

TI = clock generator starting with impulse

TP = clock generator starting with pause

IA = impulse-controlled operate delay

EW = fleeting NO contact

AW = fleeting NC contact

ARV = operate and release delayg

ON = permanent ON

OFF = permanent OFF

The time base T is selected by means of the middle, latching rotary switch T. Time-base figures available are 0.1 second, 0.5 seconds, 2 seconds, 5 seconds, 1 minute, 2 minutes, 5 minutes, 1 hour, 2 hours and 4 hours. The total time is obtained by multiplying the time base by the multiplier.

The multiplier xT is set on the upper, latching rotary switch xT and is in the range from 1 to 10. Thus, time settings can be selected in the range from 0.1 second (time base 0.1 second and multiplier 1) and 40 hours (time base 4 hours and multiplier 10).

* The maximum load can be used starting at a delay time or clock cycle of 5 minutes. The maximum load will be reduced for shorter times as follows: up to 2 seconds 15%, up to 2 minutes 30%, up to 5 minutes 60%.

Analogue settable multifunction time relay MFZ12NPwith 10 functions

MFZ12NP-230 V+8..230 V UC

E4

Function rotary switches

Typical connection

Standard setting exfactory.

Technical data page E7. Housing for operating instructions GBA12 page Z2.

MFZ12NP-230V+8..230V UC 1 NO 16 A EAN 4010312 602935 46,20 €/pc.

Recommended retail prices excluding VAT.

Page 59: Catalogo_Eltako_2009_ing

E5

Analogue settable multifunction time relay MFZ61NP

1 NO contact not potential free 10A/250V AC. Incandescent lamps 2000W*. Standby loss 0.5 watt only.Built-in device for installation and surface mounting. 45mm long, 55mm wide, 18mm deep.

Zero passage switching to protect contacts and lamps. This prolongs in particular the lifetime of energy saving lamps.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays.

By using a bistable relay coil power loss and heating is avoided even in the on mode.The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated.

Universal control voltage 8 to 230V UC. 230V supply voltage and switching voltage.

Very low switching noise.

Time settings between 0.5 seconds and 1 hour.

Functions F (description page E6)

RV = off delay

AV = operating delay

TI = clock generator starting with impulse

IA = impulse-controlled operating delay

EW = fleeting NO contact

* The maximum load can be used from a delay time or clock cycle of 5 minutes. The maximum load is reduced for shorter times as follows: up to 2 seconds 15%, up to 2 minutes 30%, up to 5 minutes 60%.

MFZ61NP-8..230 V UC

Technical data page E7.

MFZ61NP-8..230V UC 1 NO 10A EAN 4010312 603055 40,40 €/pc.

Recommended retail prices excluding VAT.

Standard setting exfactory.

Function rotary switches

Typical connection

Page 60: Catalogo_Eltako_2009_ing

E6

Description of functions of the time relays andmultifunction time relays

AW = Fleeting NC contact

When the control voltage is interrupted the NO contact changes to 15 -18,and reverts on wiping time-out. If the control voltage is applied during thewiping time the NO contact immediately reverts to 15 -16 and the residualtime is cancelled.

ARV = Operate and release delay

When the control voltage is applied the timing period starts; on time-out he relay contact changes to 15-18. If the control voltage is interrupted then,another timing period is started and, on time-out, the relay contact to normal position. On MFZ12, MFZ12NP and MFZ61NP this release delay is identical to the operating delay, on MFZ12DDX it is completely settable separately. After an interruption of the operating delay, the timing period is restarted.

ARV+ = Additive operate and release delay Same function as ARV, but after an interruption of the operate delay the elapsed time is stored.

ER = Relais As long as the control contact is closed the make contact reverts from15-16 to 15-18.

ES = Impulse switch With control impulses from 50ms the make contact switches to and fro.

IF = Pulse shaper

When the control voltage is applied the relay contact changes to 15-18 forthe set time. Further control impulses are evaluated only after the set timehas elapsed.

AV+ = Additive operate delayFunction same as AV. However, after an interruption the elapsed time is stored.

SRV = Release-delay impulse switchWith control impulses from 50ms the make contact switches to and fro. In the contact position 15-18, the device switches automatically to the rest position 15-16 on delay time-out.

EAW = Fleeting NO contact and fleeting NC contact

When the control voltage is applied or interrupted the relay contact changes to 15 -18 and reverts after the set wiping time.

A1 -A2

15-18

RV = Release delay (OFF delay)

When the control voltage is applied the relay contact switches to 15-18. When the control voltage is interrupted the timing period is started; on time-out the relay contact returns to normal position. Resettable during the timing period.

AV = Operate delay (ON delay)

When the control voltage is applied the timing period is started; on time-out the relay contact changes to 15-18. After an interruption, the timing period is restarted.

t

A1 -A2

15-18

TI = Clock generator starting with impulse (flasher relay)

As long as the control voltage is applied the relay contact opens and closes. On MFZ12, MFZ12NP and MFZ61NP the changeover time in both directions is identical, and is equal to the preset time. On EZ12TI both times can be set separately (identical time base, but additional multiplier), on MFZ12DDX it is completely settable separately. When the control voltage is applied the relay contact immediately changes to 15-18.

TP = Clock generator starting with pause (flasher relay)

Description of function same as for TI, except that, when the control voltage is applied, the contact initially remains at 15-16 rather than changing to 15-18.

t1 t2 t1

A1 -A2

15-18

EW = Fleeting NO contact

When the control voltage is applied the NO contact changes to 15 -18 and reverts on wiping time-out. If the control voltage is removed during the wiping time the NO contact immediately reverts to 15-16 and the residual time is cancelled.

t

A1 -A2

15-18

ESV = Impulse switch with release delay and switch-off early-warning function Function same as SRV. Additionally with switch-off early warning: approx.30 sec. before time-out the lighting starts flickering 3 times at graduallyshorter time intervals.

A1 -A2

15-18t

A1 -A2

15-18t1 t2

t t

A1 -A2

15-18t t

The contact 15-18 corresponds on MFZ12NP and MFZ61NP to the contact L-3. The terminals A1-A2 correspond on MFZ12NP to the terminals A1-N or C1-C2.

A1 -A2

15-18t1 t2

IA = Impulse-controlled operate delay

The timing period t1 starts with a control impulse from 50ms; on time-out the relay contact changes for the timing period t2 (for MFZ12 = 1 second, for MFZ12NP and MFZ61NP=3 seconds) to 15-18 for 1 second (e.g. for automatic door opener). If t1 is set to t1 min = 0.1 seconds, the IA operates as pulse shaper, when timing period t2 elapses, independent of the duration of the control impulse (min.150ms).

A1 –A2

15-18

A1 –A2

15-18

Page 61: Catalogo_Eltako_2009_ing

E7

Technical data time relays and multifunction time relays

ContactsMFZ12DDX b) MFZ12 b)

EZ12 b)MFZ12NP MFZ61NP b)

Contact material/contact gap AgSnO2 / 0.5 mm AgSnO2 / 0.5 mm AgSnO2 / 0.5 mm AgSnO2 / 0.5 mm

Spacing of control connections/contactSpacing control connections C1-C2 or A1-A2/contact

3mm--

3mm--

3mm 6mm

--6mm

Test voltage control connections/contactTest voltage C1-C2 or A1-A2/contact

2000V--

2000V--

2000V4000V

2000 V4000 V

Rated switching capacity 10 A/250 V AC 10 A/250 V AC 16 A/250 V AC 10 A/250 V AC

Incandescent lamp and halogen lamp load 1) 230 V 2000W 3) 2000 W 3) 2300W 3) 2000 W 3)

Fluorescent lamp load with KVG* in lead-lagcircuit or non compensated 1000 VA 3) 1000 VA 3) 1000VA 3) 1000 VA 3)

Fluorescent lamp load with KVG*shunt-compensated or with EVG* 500 VA 3) 500 VA 3) 500 VA 3) 500 VA 3)

Compact fl uorescent lamps with EVG*and energy saving lamps ESL I on <_ 70A/10ms 2) I on <_ 70A/10ms 2) 15 x 7W 3)

10 x 20W 3)15x7W 10 x 20W 3)

Max. switching current DC1: 12 V/24 V DC 8 A 8 A – –

Life at rated load, cos = 1for incandescent lamps 1000 W at 100/h

> 10 5 > 10 5 > 10 5 > 10 5

Life at rated load, cos = 0.6 at 100/h > 4 x104 > 4 x104 > 4 x104 > 4 x104

Terminal cross-section 12 mm2 12 mm2 12 mm2 clamping screw M3

Maximum conductor cross-section 6 mm2 6 mm2 6 mm2 2.5mm2

Screw headslotted /Phillips,pozidriv

slotted /Phillips,pozidriv

slotted /Phillips,pozidriv

slotted

Shock-hazard protection (on the device) VDE 0106 part 100 VDE 0106 part 100 VDE 0106 part 100 VDE 0106 part 100

Electronics

Time on 100% 100% 100% 100%

Max./min. temperature at mounting location +50°C/-20°C +50°C/-20°C +50°C/-20°C +50°C/-20°C

Temperature dependence < 0.2% per ºC < 0.2% per ºC < 0.2% per ºC < 0.2% per ºC

Repeat accuracy at 25ºC ±0.1% ±0.1% ±0.1% ±0.1%

Control voltage dependence from0.9 to 1.1x rated voltage

none none none none

Stored energy time in the event of power failure(then total reset)

>_ 0.2 seconds >_ 0.2 seconds >_ 0.2 seconds >_ 0.2 seconds

Standby loss (active power) 12V/230V 0.05/0.4W 0.05/0.4W -- /0.5W -- /0.5W

Control current 230 V-control input local ±20% – – 2mA –

Control current universal control voltage8/12/24/230V (<10s) ± 20% 0.05/ 0.1/ 0.2/1mA 0.05/ 0.1/ 0.2/1mA 2/4/9/5 (100)mA 2/4/9/5 (100)mA

Max. parallel capacitance (approx. length) of the control leads at 230 V AC 0.2μF (600m) 0.2μF (600m)

0.01μF (30m)

C1-C2:0.03μF (100m)

0.3μF (1000m)

b) Bistable relay as relay contact. The switched consumer may not be connected to the mains before the short automatic synchronisation after installation hasterminated.

1) For lamps with a load of 150W max. 2) A 40-fold inrush current must be calculated for electronic ballast devices. For steady loads of 1200W or 600W use the current-limiting relay SBR12 or

SBR61. Product group G, page G3. 3) The maximum load can be used from a delay time or clock cycle of 5 minutes. The maximum load is reduced for shorter times as follows:

up to 2 seconds 500W, up to 2 minutes 1000W, up to 5 minutes 2000W.

Compliance with: VDE 0435, EN 61000-6-3, EN 61000-6-1, EN 60 669

*EVG = electronic ballast units; KVG = conventional ballast units

Page 62: Catalogo_Eltako_2009_ing

Selection table single-phase and three-phase energy meters F0Electronic single-phase energy meters WSZ12B-32 A and 65 A F1Electronic three-phase energy meter DSZ12B-3x65 A F2Electronic double tariff three-phase energy meter DSZ12B-T2-3x65 A F2Electronic three-phase energy meter EDZ12B-3x65A F3Electronic double tariff three-phase energy meter EDZ12B-T2-3x65A F3Electronic three-phase energy meters for using with CTEDZ12WB-5A and EDZ12WS-5A F4Energy consumption indicator EVA F5Technical data F6Electronic energy meters Economy Line F7

The

cou

ntin

g c

ham

pio

ns

Electronic single-phase and three-phaseenergy meters and energy consumption indicator

F

Page 63: Catalogo_Eltako_2009_ing

The counting championsEltako offers a complete range of electronic energy meters from 32A up to 65A. Special attention should be paid to the power consumption of only 0.3W active power of the 32A and 65A single-phase devices.

All energy meters with marking B are MID approved and calibrated. 3)

If energy meters are not used for billing we recommend the "Economy Line" (page F7). Our marking is an "E" in the type designation. All electronic meters have an S0 interface according to DIN 43 864.

F0

Selection table electronic single-phase and three-phase energy meters and energy consumption indicator

1) Current transducer with adjustment of value 2) Number of decimal digits settable. 3) MID approval after setting and blocking ex work possible.

Page F2 F2 F3 F3 F4 F4 F5 F5 F6

WSZ

12B-

32A

WSZ

12B-

65A

DSZ

12B-

3x6

5A

DSZ

12B-

T2-3

x65

A

EDZ1

2B-3

x65

A

EDZ1

2B-T

2-3

x65

A

EDZ1

2WB-

5A

EDZ1

2WS-

5A

EVA1

2-32

A

Modular device for mounting on DIN railEN 50022, number of modules 18mm each 1 2 4 4 6 6 6 6 1

Single-phase energy meters

Three-phase energy meters

With MID approval 3) –

Rated current ln (Imax) A 5(32) 10(65) 10(65) 10(65) 5(65) 5(65) 51) 51) 5(32)

Display drum type register digits 6+1 6+1 6+1 6+1

Display LC display digits 6+2 6+2 5+3 8 2) 2 /4

Accuracy class MID, inaccuracy ±1% B B B B B B B B B

With return stop

Indication of misconnection

Low standby loss

S0 interface potential free

Page 64: Catalogo_Eltako_2009_ing

Electronic single-phase energy meters WSZ12B with MID approval

F1

Maximum current 65A. Standby loss 0.3 watt only.Modulair device for DIN-EN 50 022 rail mounting.2 modules = 35mm wide and 58mm deep

Accuracy class B (1%). With S0 interface as standard.

It measures active energy by means of the current between input and output. The internal powerconsumption of 0.3 watt active power is neither metered nor indicated.

1 phase conductor with a max. current up to 65A can be connected. The inrush current is 40mA. The meter can be read anytime without power supply.

WSZ12B-65 A

Typical connection

Unverbindliche Preisempfehlung zuzüglich gesetzl. MwSt.

Maximum current 32A. Standby loss 0.3 watt only.Modulair device for DIN-EN 50 022 rail mounting. 1 module = 18mm wide and 58mm deep

Accuracy class B (1%). With S0 interface as standard.

It measures active energy by means of the current between input and output. The internal power consumption of 0.3 watt active power is neither metered nor indicated.

1 phase conductor with a max. current up to 32A can be connected. The inrush current is 20mA. The meter can be read anytime without power supply.

Two N terminals for secure cross wiring of several counters.

WSZ12B-32A

Technical data page F7. Housing for operating instructions GBA12 page Z2.

Typical connection A red LED indicates a power consumption or a possible wrong connection.

Energy meter wrongly connected, ( L- L vice-versa connected), with or without power consumption

Energy meter correctly connected, with power consumption

T = depends on power consumption 2000 Imp./kWh

Energy meter connected, no power consumption

WSZ12B-32A MID approval EAN 4010312 500507 129,00 €/pc.

A red LED indicates a power consumption or a possible wrong connection.

Energy meter wrongly connected, ( L- L vice-versa connected), with or without power consumption

Energy meter correctly connected, with power consumption

T = depends on power consumption 1000 Imp./kWh

Energy meter connected, no power consumption

Technical data page F7. Housing for operating instructions GBA12 page Z2.

WSZ12B-65A MID approval EAN 4010312 500460 140,00 €/pc.

Recommended retail prices excluding VAT.

time time time

timetimetime

Page 65: Catalogo_Eltako_2009_ing

Electronic three-phase and double tariff three-phase energy meters DSZ12B with MID approval

F2

Unverbindliche Preisempfehlung zuzüglich gesetzl. MwSt.

Maximum current 3x65A. Standby loss 0.5 watt per path only.Modulair device for DIN-EN 50 022 rail mounting.4 modules = 70mm wide and 58mm deep.

Accuracy class B (1%). With S0 interface as standard.

It measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power per path is neither metered nor indicated.

1, 2 or 3 phase conductors with max. currents up to 65A can be connected. The inrush current is 40mA. The meter can be read anytime without power supply.

The N terminal must always be connected.

DSZ12B-3x65 A

Technical data page F7. Housing for operating instructions GBA12 page Z2.

Typical connection

Maximum current 3x65A. Standby loss 0.5 per path only.Modulair device for DIN-EN 50 022 rail mounting.4 modules = 70mm wide and 58mm deep. Accuracy class B (1%). With S0 interface as standard.2 registers HT (high tariff) and NT (low tariff). It measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power per path is neither metered nor indicated.1, 2 or 3 phase conductors with max. currents up to 65A can be connected. The inrush current is 40mA. The tariff is selected at 230V by terminals E1/E2 and the registers can be read anytime without power supply.

The N terminal must always be connected.

DSZ12B-T2-3x65 A

Typical connectionThree red LEDs will show a power consumption or a possible wrong connection.

Two red LEDs will show a power consumption or a possible wrong connection.

Technical data page F7. Housing for operating GBA12 page Z2.

DSZ12B-3x65A MID approval EAN 4010312 500552 239,00 €/pc.

DSZ12B-T2-3x65A MID approval EAN 4010312 500576 279,00 €/pc.

Recommended retail prices excluding VAT.

LED tarif (red)

LED error (red)

Depending on the meteredpower consumption

100 Imp/kWh

Pulse width 100ms, pulse/break relation for several pulses 1/1

SO-output

LEDerror

no error error at L1 error at L2 error at L3 error at L1 and L2

error at L1 and L3

error at L1, L2 and L3

LED tarif (red)

LED error (red)

Depending on the meteredpower consumption

100 Imp/kWh

Pulse width 100ms, pulse/break relation for several pulses 1/1

no error error at L1 error at L2 error at L3 error at L1 and L2

error at L1 and L3

error at L1, L2 and L3

SO-outputchoice of tariff 230V

LEDtariff 2

tariff 1 tariff 2

LEDtariff

LEDerror

LEDtariff

Page 66: Catalogo_Eltako_2009_ing

Elektronische Wechselstromzähler WSZmit Zulassung und geeichtElectronic three-phase and double tariff three-phase energy meters EDZ12B with MID approval

F3

Maximum current 3x65A. Standby loss 1 watt per path only.Modulair device for DIN-EN 50 022 rail mounting.6 modules = 108mm wide and 56mm deep.

Accuracy class B (1%). With S0 interface as standard.

This direct metering double tariff three-phase energy meter measures active energy by means of the current between input and output. The internal power consumption of 1 watt active power per path is neither metered nor indicated.

1, 2 or 3 phase conductors with max. currents up to 65A can be connected. The inrush current is 20mA. LC display with 6 digits for kWh and 2 decimal digits. Choice of tariff is carried out through 230V by terminals 13/15.

The active tariff is indicated on the display with T1 or T2.With a push-button next to the display the meter readings tariff 1 and tariff 2 as well as the instantaneous values total power as well as power, voltage and current per phase can be indicated.

This indication is also possible in case of a power failure due to a lithium battery that ensures the power supply for 30 hours.

Display of power consumption with a red LED, 1000 Imp/kWh.If no power is consumed the red LED is permanently illuminated. Errors are indicated on the display: L1-L2-L3 blink if phases or input/output are inverted.

Trifurcated rail mounting with sinistral N-connection possible.The N terminal must always be connected.

EDZ12B-T2-3x65 A

Technical data page F7.

Maximum current 3x65A. Standby loss 1 watt per path only.Modulair device for DIN-EN 50 022 rail mounting.6 modules = 108mm wide and 56mm deep.

Accuracy class B (1%). With S0 interface as standard.

This direct metering three-phase energy meter measures active energy by means of the current between input and output. The internal power consumption of 1 watt active power per path is neither metered nor indicated.

1, 2 or 3 phase conductors with max. currents up to 65A can be connected. The inrush current is 20mA. LC display with 6 digits for kWh and 2 decimal digits.

Display of power consumption with a red LED, 1000 Imp/kWh.If no power is consumed the red LED is permanently illuminated. Errors are indicated on the display: L1-L2-L3 blink if phases or input/output are inverted.

With a push-button next to the display the instantaneous values total power as well as power, voltage and current per phase can be indicated.

Trifurcated rail mounting with sinistral N-connection possible.The N terminal must always be connected.

EDZ12B-3x65 A

EDZ12B-3x65A MID approval EAN 4010312 500484 279,00 €/pc.

Technical data page F7.

Typical connection 4-wire-connection 3x230/400V

EDZ12B-T2-3x65A MID approval EAN 4010312 500712 325,00 €/pc.

Recommended retail prices excluding VAT.

Typical connection4-wire-connection 3x230/400V

Page 67: Catalogo_Eltako_2009_ing

F8F4

Electronic CT operated three-phase energy meters EDZ12W with MID approval

Maximum current 3x5A. With settable CT ratio.Standby loss 1 watt per path only.Modulair device for DIN-EN 50 022 rail mounting.6 modules = 108mm wide and 56mm deep.

Accuracy class B (1%). With S0 interface as standard.

This CT operated three-phase energy meter can be blocked by the customer after setting the transducer ratio and then it can also be calibrated if requested. *MID approval possible for additional fee if set and blocked ex factory.It measures active energy by means of the currents between inputs and outputs. The internal power consumption of 1 watt active power per path is neither metered nor indicated.

2 or 3 current transducers with secondary currents up to 5A can be connected. The inrush current is 2mA only. LC display with 8 digits, up to 4 decimal digits settable.

Display of power consumption with a red LED, 10 000 Imp/kWh.If no power is consumed the red LED is permanently illuminated. Errors are indicated on the display: L1-L2-L3 blink if phases or input/output are inverted.

With a push-button next to the display the instantaneous values total power as well as power, voltage and current per phase can be indicated.

With this push-button the transducer ratio and the S0 impulse output can be set in the edit mode.

The N terminal must always be connected.

EDZ12WS-5 A

Technical data page F7.

Maximum current 3x5A. Standby loss 1 watt per path only.Modulair device for DIN-EN 50 022 rail mounting.6 modules = 108mm wide and 56mm deep.Accuracy class B (1%). With SO interface as standard.This three-phase energy meter measures active energy by means of the current between input and output. The internal power consumption of 1 watt active power per path is neither metered nor indicated.2 or 3 phase conductors with max. currents up to 5A can be connected. The inrush current is 2mA. LC display with 5 digits for kWh and 3 decimal digits.Display of power consumption with a red LED, 10 000 Imp/kWh.

If no power is consumed the red LED is permanently illuminated. Errors are indicated on the display: L1-L2-L3 blink if phases or input/output are inverted.With a push-button next to the display the instantaneous values total power as well as power, voltage and current per phase can be indicated.

The N terminal must always be connected.

EDZ12WB-5 A

EDZ12WB-5A MID approval EAN 4010312 500606 287,70 €/pc.

Technical data page F7.

Typical connection4-wire-connection 3x230/400V

EDZ12WS-5A * EAN 4010312 500613 287,70 €/pc.

Recommended retail prices excluding VAT.

Typical connection4-wire-connection 3x230/400V

Page 68: Catalogo_Eltako_2009_ing

F5

Energy consumption indicator EVA12 with display - smart metering

Maximum current 32A, standby loss 0.3 watt only.Modular device for DIN-EN 50 022 rail mounting.1 module = 18 mm wide, 58mm deep.

The energy consumption indicator EVA12 uses the current between input and output to measure active energy in the same way as a single-phase power meter. It saves the consumption parameter in a non-volatile memory. Accuracy conforms to Class 1 PTB and Class B MID ( 1%) like all Eltako single-phase energy meters. The inrush current is also 20mA.

In this way the energy consumption indicator reproduces exactly the reading on the billing energy meter installed at a different location in the building. The display is subdivided into 3 segments.

Segment 1: This display refers to the cumulative value in segment 3. IIII moving slowly to the right = Segment 3 shows the cumulative consumption since last total reset. This is the display standard mode.

H01 = Segment 3 shows the consumption for the last hour up to H24 = 24 hours ago.

D01 = Segment 3 shows the consumption for the last day up to D31 = 31 days ago.

M01 = Segment 3 shows the consumption for the last month up to M12 = 12 months ago.

Y01 = Segment 3 shows the consumption for the last year up to Y24 = 24 years ago.

Segment 2: Instantaneous values of energy consumption (active power) in watt (W) or kilowatt (kW). The display arrows on the left and right show the automatic change W and kW.

Segment 3: Cumulative value in kWh.

Press the left button MODE to scroll down the display options which are shown in segment 1:H01, D01, M01 and Y01 as described above. Finally, press MODE to show the abbreviation of the set language, e.g. GB for English, D for German and F for French.

Press the right button SELECT once within the display options to increment the indicated figure by 1. The corresponding value is indicated in segment 3. The last clock hour thenbecomes the hour before last, etc.

If the active language was selected with MODE, press SELECT to switch to a different language. Exit the new language setting by pressing MODE to activate the setting.

The program returns to the standard display mode automatically if MODE or SELECT are not operated for 20 seconds or if you press both buttons briefly simultaneously.

Total resetTo start saving the values to the nearest hour, we recommend performing a total reset at an opportune moment after installation. Hold down the buttons MODE and SELECT simultaneously for a further 5 seconds until RES appears. Then press SELECT briefly to reset all memories. Afterwards the program returns automatically to standard display mode.

EVA12-32 A

EVA12-32A Maximum current 32A EAN 4010312 500828 59,90 €/pc.

Typical connection

Technical data page F7.

Recommended retail prices excluding VAT.

segment 1

segment 3

segment 2

segment 1

segment 3

segment 2

Page 69: Catalogo_Eltako_2009_ing

F8F6

Technical data electronic single-phase and three-phase energy meters and energy consumption indicator

WSZ12B-32AEVA12-32A

WSZ12B-65 A DSZ12B-3x65 ADSZ12B-T2-3x65 A

EDZ12B-3x65 AEDZ12B-T2-3x65 A

EDZ12WB-5AEDZ12WS-5A

Rated voltageExtended range

230 V, 50Hz, -2O% /+15%

230 V, 50Hz, -2O% /+15%

3x230/400 V, 50Hz, -2O%/+15%

3x230/400V, 50Hz, -2O% /+15%

3x230/400V, 50Hz, -2O% /+15%

Rated current In (Limiting current I max)

5(32) A 10 (65) A 10 (65) A 5 (65)A (5)A

Internal consumptionActive power

0.3 W 0.3 W 0.5 W per path 1W per path 1W per path

Reading active powerEVA12: LC displayDrum type register with 6 digits for kWh and 1 decimal digit; DSZ12B-T2 with one drum type register per tariff

EDZ12B: LC display, 6 digits for kWh and 2 decimal digitsEDZ12WB: 5 digits for kWh and 3 decimal digitsEDZ12WS: 8 digits, up to 4 decimal digits settableEDZ12B-T2: with one key to select tariff 1 or tariff 2

Reading instantaneous values

EVA12:active power

-- --With key to select total power as well as power, voltage and current per phase

Accuracy class ±1% B

Inrush current according to accuracy class B

20mA 40mA 40mA 20mA 2mA

Ambient temperature limits -25/+55°C

Interface(not EVA12)

Pulse interface S0 according to DIN EN 62053-31, potential free by opto-coupler, max. 30V DC/2OmA and min. 5V DC, impedance 100 ohms, pulse length 50 ms

Pulse interface S0 according to DIN EN 62053-31, potential free by an OptoMOS unit, max. 230V UC, 100 mA;EDZ12B: Impulse length 30 ms, 1000 Imp./kWhEDZ12WB: Impulse length 100 ms, 1000 Imp./kWhEDZ12WS: Pulse constant in steps from 100 to 10000 andpulse length from 30 to 100 ms settable with key2000 Imp./kWh 1000 Imp./kWh 100 Imp./kWh

Terminal cover sealable --

With sealing cap PK36. For the current path 1 sealing cap is required

With terminal cover claps (MID) or with sealing cap PK36 (PTB). For the current pathes 2 sealing caps are required

Terminal cover claps Terminal cover claps

Protection degree lP50 for mounting in distribution cabines with protection class IP51

Maximum conductor cross section 6 mm2 N and L terminals 16 mm2,

S0 terminals 6 mm2N and L terminals 16 mm2, S0 terminals 2.5 mm2

N and L terminals 4mm2, S0 terminals 2.5 mm2

Compliance with: EN 62 053-21, EN 50470 (MID)

The N terminal of three-phase energy meters must be connected, if not the electronics might be destroyed.

Page 70: Catalogo_Eltako_2009_ing

F7

Electronic Energy MetersEconomy Line

S0-interface for connecting to energy management systems Accuracy class 1, non-calibrated The internal power consumption is not metered

The reliable and reasonable alternative to determine the consumption of energy

Typical connections Economy Line

Technical Data

EWZ12E-32A WSZ12E-32A DSZ12E-3x65ADSZ12E-T2-3x65A

Type Single-phase energy meter Single-phase energy meter Three-phase energy meter

Width per module 18mm wide 18mm wide 72mm wide

Rated voltage 230V, 50Hz 230V, 50Hz 3x230/400V, 50Hz

Rated current In (Imax) 5(32) A 5(32) A 5(65) A

Internal power consumptionActive power

0.3 W 0.3 W 0.5 W each current circuit

Reading active powerDisplay with 7 digits. Up to 99999.99 kWh 2 decimal places thereafter 1 decimal place

Drum type register with 6 digits for kWh and 1 red decimal digit

Display drum type register(s) with 6 digits for kWh and 1 red decimal digit

Accuracy class ±1% 1 1 1

Inrush current 20mA 20mA 40mA

Ambient temperature limits -25/+55°C -25/+55°C -25/+55°C

InterfacePulse interface S0 according to DIN EN 62053-31, potential free by opto-coupler, max. 30V DC/2OmA and

min. 5V DC, impedance 100 ohms, pulse length 50 ms.

2000 Imp./kWh 2000 Imp./kWh 100 Imp./kWh

EWZ12E-32AWSZ12E-32ADSZ12E-3x65ADSZ12E-T2-3x65A

non-calibratednon-calibratednon-calibratednon-calibrated

EAN 4010312 500774EAN 4010312 500644EAN 4010312 500668EAN 4010312 500675

47,00 €/pc.88,90 €/pc.

198,20 €/pc.234,10 €/pc.

Compliance with: EN 62 053-21 (EN 61036); Recommended retail prices excluding VAT.

Display drum type register with 6 digits for kWh and 1 red decimal digit,

EWZ12E-32A: 5 digits for kWh and 2 decimal digits

EWZ12E-32A and WSZ12E-32A DSZ12E-3x65A DSZ12E-T2-3x65A

SO-output

LEDerror

SO-outputchoice oftariff

LEDtariff 2LED

tariff

LEDerror

LEDtariff

tariff 1 tariff 2

Page 71: Catalogo_Eltako_2009_ing

The

bo

dyg

uar

ds

Switching on the future.

Current relay, mains monitoring relay, current-limiting relay and mains disconnection relay

Selection table bodyguards G0Current relay AR12NP G1Mains monitoring relay NR12 G2Current-limiting relay SBR12 and SBR61 G3Self-learning mains disconnection relay FR12 G4Self-learning mains disconnection relay FR61 and accessory base load GLE G5Technical data and phase annunciator P3K12 G6

G

Page 72: Catalogo_Eltako_2009_ing

G0

The bodyguardsELTAKO mains disconnection relays switch off a monitored 230V conductor after connected loads are switched off manually. This prevents interfering electromagnetic alternating fi elds.

A DC voltage with an extremely low residual ripple is used for monitoring purposes. No measurable alternating fi eld is generated but it is guaranteed that room lighting is detected when switched on. The monitored conductor is then switched on again.

Electronically controlled loads or supplied loads, require a high degree of monitoring effort. Here, the self-learning mainsdisconnection relays are ideal for such applications.

Page G1 G2 G2 G3 G3 G4 G5 G6

pict

ogra

ms

AR12

NP-

230

V

NR1

2-00

1-3

x230

V

NR1

2-00

2-3

x230

V

SBR1

2-23

0V/

240

μF

SBR6

1-23

0V/

120

μF

FR12

-230

V

FR61

-230

V

P3K1

2

Modular device for mounting on DIN rail EN 50022, number of modules 18mm each

1 1 2 1 1 1

Built - in device for installation (e.g. fl ush-mounting box) andsurface mounting

Number NO contacts or CO contacts potential free (not potential free)

(1W) 1W 2W 1 1 (1) (1) –

Zero passage switching

Switching capacity 16A /250V AC –

Switching capacity 10A /250V AC –

Incandescent lamp load W 2300 1600 1600 1200 600 2300 1000 –

Fluorescent lamp load with EVG* andenergy saving lamps W

210-400Ion <_70A/

10ms 1)Ion <_70A/

10ms 1) 1200 600Ion <_70A/

10ms 1)Ion <_70A/

10ms 1) –

Supply voltage 230V

No standby loss

Low standby loss

Current relay

Mains monitoring relay

Current-limiting relay

Mains disconnection relay

Phase annunciator

Selection table current relay, mains monitoring relay, current-limiting relay and mains disconnection relay

1) A 40- fold inrush current must be expected for electronic ballast devices. Limit with SBR12 or SBR61 if applicable.

*EVG = electronic ballast units

Page 73: Catalogo_Eltako_2009_ing

G1

1 CO contact not potential free 16A/250V AC.Standby loss 0.8 watt only.Modular device for DIN 50022 rail mounting.1 module=18mm wide, 58mm deep.

With an internal toroidal-core current transformer the single phase AC current flowing through a consumer V1 of 0.1A up to max. 32A is compared to the setpoint. When the latter is exceeded a special relay with high capacity switches off a consumer V2 connected to 2 within 0.5 seconds or switches on a consumer V3 connected to 3.

Adjustment accuracy ±5%. From 25A the relay always switches on.

Zero passage switching to protect contacts and consumers.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays.

The basis of current A will be set with the lower rotary switch A. The following basic values can be selected: 0.1A, 0.3A, 0.6A, 0.9A,1.5A,1.9A, 3.0A and 3.2A.

The multiplier xA will be set with the middle rotary switch xA and offers values between 1and 10. So currents starting from 0.1A (basis of current 0.1A and multiplier 1) can be set.

OFF delay RV can be set with the upper rotary switch RV between 0 and 120 secs.

The hysteresis is defined as approx. 25%.

Status indication by LED.

The measuring input M1-M2 is electrically isolated from power supply L -N and make contact L -2/3.

Reference values larger than 32A can be adapted by an external measuring transformer.

AR12NP-230V

Current relay AR12NP

Technical data page G6. Housing for operating instructions GBA12 page Z2.

Function rotary switches

3.0 3.2

Standard setting ex factory.

Typical connection

AR12NP-230V 1 CO 16A EAN 4010312 205426 60,80 €/pc.

Recommended retail prices excluding VAT.

Page 74: Catalogo_Eltako_2009_ing

G2

1 CO contact potential free 10A/250V AC. Standby loss 0.8 watt only.Modular device for DIN 50022 rail mounting.1 module=18mm wide, 58mm deep.

Designed to monitor 230V AC voltage between 1 to 3 phase conductors and neutral and tomonitor the rotating field (clockwise) in the switch positions 2Ph and 3Ph.

In the position only the rotating field is monitored, independent from the mains voltage.

Supply voltage L1-N 180-250V/50-60Hz.In case of failure of L1 the relay releases immediately without delay.

With the lower rotary switch on the front two operate voltages resp. dropout voltages can beset and the number of monitored phase conductors must be selected.U1: 161V dropout voltage and 185V operate voltage.U2: 196V dropout voltage and 206V operate voltage as per VDE 0100, part 718 (formerly: VDE 0108, part 1).

Voltage applied signalled by LED. At wrong polarity or in case of a missing phase conductorthe LED flashes rapidly.

Release delay RV settable with the upper rotary switch from 0.1 to 8sec.The LED flashes slowly during the release delay time period. Operate delay 0.5sec.

Maximum fusing 16A.

Mains monitoring relays NR12monitoring the rotating field

Technical data page G6. Housing for operating instructions GBA12 page Z2.

NR12-001-3x230 V

2 CO contacts potential free 10A/250V AC. Standby loss 0.8 watt only.Modular device for DIN 50022 rail mounting.2 modules=32mm wide, 58mm deep.

All functions same as NR12-001-3x230V but with a second NO contact.

Maximum fusing 16A.

NR12-002-3x230V

Technical data page G6. Housing for operating instructions GBA12 page Z2.

Function rotary switches

Typical connections: 1 phase monitoring 3 phase monitoring

NR12-002-3x230V NR12-002-3x230V NR12-001-3x230VNR12-001-3x230V

NR12-001-3x230V 1 CO 10A EAN 4010312 202524 53,00 €/pc.

NR12-002-3x230V 2 CO 10A EAN 4010312 202548 76,50 €/pc.

Recommended retail prices excluding VAT.

Page 75: Catalogo_Eltako_2009_ing

Recommended retail prices excluding VAT..

Current-limiting relays capacitive SBR

1 NO contact 16A/250V AC. No standby loss.Modular device for DIN 50022 rail mounting.1 module=18mm wide, 58mm deep.

Max. capacitive load 240μF downstream of rectifier (e.g. energy saving lamps and electronic ballast) or 120μF directly at the mains (e.g. shunt-compensated fluorescent lamps).Limiting resistor 12 , limiting period approx. 15msec.

The starting current impulse of energy saving lamps, fluorescent lamps and compact fluorescent lamps is limited to 20A by short-time switch-on (approx. 15 msec.) of heavy-duty resistors (12 ).The current-limiting relay is connected on the load side of the protected relay contact.

Permanent load max. 1200W, max. switching frequency 600/h.

Explanation of capacitive load specification:The specified max. capacitive load directly at the mains is the deciding factor determining shunt-compensated fluorescent lamps or conventional ballast, for example. Here the capacitor switched in parallel to the mains is the deciding factor determining the correct dimensioning per lamp.The specified max. capacitive load downstream of the rectifier is the deciding factor determining fluorescent lamp ballast or energy saving lamps, for example. An equivalent capacitance of 10μF per lamp may be calculated.

SBR12-230V/240 F

ESR12M or ES12Z with SBR12-230 V/240 μFG3

Typical connection

1 NO contact 10A/250V AC. No standby loss.Built-in device for installation and surface mounting 45mm long, 55mm wide, 18mm deep.

Max. capacitive load 240μF downstream of rectifier (e.g. energy saving lamps and electronic ballast) or 120μF directly at the mains (e.g. shunt-compensated fluorescent lamps).Limiting resistor 24 , limiting period approx. 15ms.

The starting current impulse of energy saving lamps, fluorescent lamps and compactfluorescent lamps is limited to 10A by short-time switch on (approx. 15 msec.) ofheavy-duty resistors (24 ).The current-limiting relay is connected on the load side of the protected relay contact.

Permanent load max. 600W, max. switching frequency 600/h.

Explanation of capacitive load specification:The specified max. capacitive load directly at the mains is the deciding factor determining shunt-compensated fluorescent lamps or conventional ballast, for example. Here the capacitor switched in parallel to the mains is the deciding factor determining the correct dimensioning per lamp.The specified max. capacitive load downstream of the rectifier is the deciding factor determining fluorescent lamp ballast or energy saving lamps, for example. An equivalent capacitance of 10μF per lamp may be calculated.

SBR61-230V/120 F

Typical connection

SBR12-230V/240μF 1 NO 16A EAN 4010312 205457 33,00 €/pc.

SBR61-230V/120μF 1 NO 10A EAN 4010312 205464 29,70 €/pc.

Recommended retail prices excluding VAT.

check back signal

localON/OFF

Page 76: Catalogo_Eltako_2009_ing

1 NO contact not potential free 16A/250V AC.Incandescent lamp load 2300W. Standby loss 0.8 watt only.Modular device for DIN EN 50 022 rail mounting.1 module =18mm wide and 58mm deep.

230V supply voltage and switching voltage.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

The FR12-230V mains disconnection relay disconnects the power supply once all series connected loads are turned off, thus preventing any electromagnetic interference fields from occurring.Small loads up to 200mA, are acceptable and, once major loads are disconnected, they do not prevent field disconnection. There is no need to manually set the limit; it is learned by the FR12. Loads drawing more than 200mA are consistently defined as loads which should cause the line power to be connected.

As long as no major load is turned on, one pole of the monitored circuit remains isolated fromthe mains. Neutral and earth are connected continuously to avoid acting as an aerial.

A DC voltage with an extremely low residual ripple is applied for monitoring.Therefore, it is prohibited to bridge the relay contact, which would ultimately cause device failure.

When a load is turned on, the mains disconnection switch connects the monitored phase after approx. 1 sec and the LED lights red.

Function of the lower rotary switchIn the function ON/ position, the relay contact is continuously closed and field disconnection deactivated.

Turn the switch to the position A = automatic with 'self-learn mode', the actual current value is saved as a switch-off value. When this value is reached, the FR12 breaks the electrical circuit regardless whether small consumers such as electronic dimmers are connected. Therefore, the lighting must always be OFF for learning by means of the rotary switch.

When the switch is in the A position the FR12 adapts to changes in connected consumers. The FR12 performs a new learn-in routine after phase is activated and when the power supply is restored after a power failure.

If a new small load is switched on for more than 24 hours, the total current drawn by the monitored circuit is less than 200mA, the FR12 is set to A mode and in the meantime the light has been switched on and off, the new load is learned in and the conductor is switched off. When the rotary switch is set briefly from A to , learn-in takes place immediately after connecting a new load. If the function self-learn is not required, set the rotary switch to A ‚automatic OFF‘.

Function of the upper rotary switchThe monitoring voltage can be adjusted in the range from 5V DC to 230V DC. Due to its low residual ripple, it generates no measurable alternating field even at 230V DC. The higher the adjustment, the greater the number of capacitive loads detectable without switching on a base load. It can therefore be reduced until the loads are barely detectable. In many applications, even the lowest monitoring voltages are detectable.

FR12-230 V

G4

Self-learning mains disconnection relay FR12

FR12-230V

Rotary switches

Standard setting ex factory.

Technical data page G6. Housing for operating instructions GBA12 page Z2.

monitored circuit

Typical connection

FR12-230V 1 NO 16A EAN 4010312 203255 87,00 €/pc.

Recommended retail prices excluding VAT.

Page 77: Catalogo_Eltako_2009_ing

Accessory base load A base load is used if loads cannot be detected due to their capacitance but are meant to switchon the line voltage. Base loads must consistently start or operate in parallel with the related loadand be turned off with the latter. Higher stand by loads may affect or jam the detection of a base load. Typical applications: Fluorescent lamps, dimmer circuits and electronic transformers.

GLE base load elementPTC in a small coupler with connecting leads; can be used directly in a load, a switch box or a junction box. It is not capable of keeping the mains disconnection relay in the connected state without an additional load connected.

GLE

G5

1 NO contact not potential free 10A/250V AC. Standby loss 0.8 watt only.Built-in device for installation and surface mounting 45mm long, 55mm wide, 26mm deep.230V supply voltage and switching voltage.

State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays.

The FR61-230V mains disconnection relay disconnects the power supply once all series connected loads are turned off, thus preventing any electromagnetic interference fields from occurring.

Small loads up to 20mA are acceptable and, once major loads are disconnected, they do not prevent field disconnection. There is no need to manually set the limit; it is learned by the FR61. Loads drawing more than 200mA are consistently defined as loads which should cause the line power to be connected.

As long as no major load is turned on, one pole of the monitored circuit remains isolated from the mains. Neutral and earth are connected continuously to avoid acting as an aerial.

A DC voltage of 230V DC with an extremely low residual ripple is applied for monitoring. Therefore, it is prohibited to bridge the relay contact, which would ultimately cause device failure.

When a load is turned on, the mains disconnection relay connects the phase.

If the phase is switched on for the first time and after a power failure the FR61 automatically learns in again: At first an inrush current of 30mA is specified. If a new small load is switched on for more than 24 hours, the total current drawn by the monitored circuit is less than 200mA, and in the meantime the light has been switched on and off, the new load is learned in and the conductor is switched off. This learn-in mode can be realised immediately after connection of the new load by briefly switching off the MCB.

FR61-230 V

Self-learning mains disconnection relay FR61, accessory base load

Technical data page G6.

monitored circuit

Typical connection

Side view

FR61-230V 1 NO 10A EAN 4010312 203477 87,00 €/pc.

GLE 1x base load EAN 4010312 900970 5,00 €/pc.

Recommended retail prices excluding VAT.

Page 78: Catalogo_Eltako_2009_ing

G6

Phase annunciator P3K12 and technical data current relay, mains monitoring relay and mains disconnection relay

Compliance with: EN 61000-6-3, EN 61000-6-1 and EN 60669

Contacts NR12 AR12NP/FR12 FR61

Contact material AgSnO2 / 0.5 mm AgSnO2 / 0.5 mm AgSnO2 / 0.5 mm

Spacing of control connections/contact > 6mm –, AR12NP: > 6mm –

Test voltage contact to contactTest voltage control connection to contact

–, NR12-002: 2000 V4000 V

––, AR12NP: 4000 V

––

Rated switching capacity 10 A/250 V AC 16 A/250 V AC 10 A/250 V AC

Incandescent lamp and halogen lamp load 1) 230V 2000W 2300W 1000 W

Fluorescent lamp load with KVG* in lead-lag circuitor non compensated

1000 VA 1000 VA 1000 VA

Fluorescent lamp load with KVG* shunt-compensated or with EVG*

500 VA 1000 VA 500 VA

Compact fl uorescent lamps with EVG*and energy saving lamps ESL

I on <_ 70A/10ms 2)I on <_ 70A/ 10ms 2)

AR12NP: 15x7W,10x20 W

I on <_ 70A/ 10ms 2)

Max. switching current DC1: 12V /24V DC 8 A – –

Life at rated load, cos = 1 at 100/h > 10 5 > 10 5 > 10 5

Life for incandescent lamps 1000W at 100/h > 10 5 > 10 5 > 10 5

Life at rated load, cos = 0.6 at 100/h > 4 x104 > 4 x104 > 4 x104

Max. operating cycles 103/h 103/h 103/h

Switching position indication /voltage indication LED LED –

Terminal cross-section 12 mm2 12 mm2 clamping screw M3

Maximum conductor cross-section 6 mm2 6 mm2 2.5 mm2

Screw head slotted /Phillips, pozidriv slotted /Phillips, pozidriv slotted

Shock-hazard protection (on the device) VDE 0106 part 100 VDE 0106 part 100 VDE 0106 part 100

Electronics

Time on 100% 100% 100%

Max./min. temperature at mounting location +50°C/-20°C +50°C/-20°C +50°C/-20°C

Control voltage range 180-250V/50-60Hz 0.9 to 1.1xrated voltage 0.9 to 1.1xrated voltage

Stand by loss (active power) 0.8 W 0.8 W 0.8 W

Max. parallel capacitance (length) of control lead 0.06 μF (200m) 0.06 μF (200m) 0.06 μF (200m)

Phase annunciator. Standby loss 0,06 watt only. Modular device for DIN 50022 rail mounting.1 module = 18mm wide, 58mm deep.

For visual monitoring of 1 to 3 phases 230V.

Indication with three red LEDs.

P3K12

1) Applies to lamps with max. 150W. 2) A 40-fold inrush current must be expected for electronic ballast devices.

Technical data

P3K12-230V EAN 4010312 701065 25,00 €/pc.

*EVG = electronic ballast units; KVG = conventional ballast units

Page 79: Catalogo_Eltako_2009_ing

The

mo

du

lar

app

roac

h

Switching on the future.

Shading systems androller shutter control

The modular approach for the electrical trade H0Sensors for brightness, wind, rain, and frost H1Multifunction sensor relay MSR12 H2Sensor relay for light, twighlight and wind LDW12 H3Actuator impulse group switch EGS12Z H4Actuator impulse group switch EGS12Z2 H5Motor isolating relay MTR12 and DC motor relay DCM12 H5Actuator impulse group switch EGS61Z H6Installation guidelines and technical data H7Typical circuit example H8

H

Page 80: Catalogo_Eltako_2009_ing

The modular approach for the electrical trade Planning and realisation of a shading system or roller shutter control are classical tasks for the electrical installer.ELTAKO has developed a well thought-out modular system of control devices and switchgear for mounting in switch cabinets and distribution boards.The modular approach has been chosen to provide a control or switchgear device (module) for any desired function match the overall system, typically permitting an individual awning to be controlled as perfectly as a large system which comprises dozens of shutters, awnings, Venetian blinds, etc.Any assignment of control devices to the switchgear devices can be chosen, and provision is made for easy modifi cations,retrofi tting and expansion, "bit by bit".There are four groups of devices1. SensorsSensors serve to detect the actual situation. A light sensor, for example, measures brightness and generates a control voltage as a function of it. Momentary contact switches are switches employed to transmit the SHUT or OPEN condition in terms of avoltage.2. Sensor relaysSensor relays serve to convert the sensor-produced actual signals to control signals as a function of practical set points, whilst logic operations are performed and faulty sensors detected. Signals from switches and momentary contact switches do not require series-connected sensor relays as they act directly on actuators.3. ActuatorsActuators serve to control the motors of shading systems and roller shutters. These are group impulse switches in hybrid technology with central control functions and possibly motor isolating relays or DC motor relays.4. AccessoriesWide-range switching power supply units for the power supply of the multi sensor and the multifunction sensor relay are available as accessories.

The principle of overall control is quite simple: each shading element or its motor is controlled by an actuator that receives commands via sensors and, where fi tted, sensor relays.A complete Control System consists (as the smallest unit) of a switch or momentary contact switch controlled EGS12Z group impulse switch for one motor. The largest unit comprises any number of sensors and sensor relays as well as any number of impulse group switches EGS12Z and EGS12Z2 with or without motor isolating relay MTR12 and DC motor relay DCM12 to control the motors.

Page H2+H3 H4-H6

Sensors Sensor relays Actuators

Multi sensor MSMultifunction sensor relay MSR12 for brightness, twiligth, wind, rain and frost

Group impulse switch EGS12Z and EGS12Z2

Light sensor LSMultifunction sensor relay MSR12 for brightness, twiligth, wind, rain and frost

Group impulse switch EGS61Z

Wind sensor WSLight-twilight-wind sensor relay LDW12 for light, twilight and wind

Motor isolating relay MTR12

Switches, momentary contact switchesLight-twilight-wind sensor relay LDW12 for light, twilight and wind

DC motor relay DCM12

Shading systems and roller shutter control

H0

Page 81: Catalogo_Eltako_2009_ing

H1

Sensors MS, LS, WS, On/Off switch andmomentary-contact switches

The MS multi sensor sends the current weather details, including brightness (from three points of the compass), wind, rain and frost, to the multifunction sensor relay MSR12 connected in series once per second. A standard telephone wire is suffi cient as connecting lead: J-Y(ST)Y 2x2x0,8 or equivalent. 100m line length is permitted.

Solid plastic housing, l x w x h = 118x96x77mm. Degree of protection IP44.Temperature at mounting location -30°C to +50°C.

A power supply unit WNT12-24V DC-6W (page I0) is required for the power supply, including heating of the rain sensor. This is only 1 module =18mm wide and it also it supplies the multifunction sensor relay MSR12 (page H2).

Several MSR12 can be connected to a multisensor MS, e.g. for evaluating up to three directions with the light sensor of the MS.

Multi sensor MS

The LS light sensor generates a voltage dependent on light intensity by means of a photo resistor. This voltage is evaluated in a USR12 universal sensor relay or an LSR12 light and twilight sensor relay connected in series.

Solid plastic housing, l x w x h = 37x25x68 mm. IP 54 enclosure protection.

For mounting, use aluminium bracket, or the fastening screw that also comes with the device, directly on the KM1 plastic mounting bracket of the wind sensor. Without measuring lead.

Light sensor LS

The WS wind sensor provides a sequence of pulses as a function of the wind vane speed.This pulse sequence is evaluated in a LDW12 universal sensor relay connected in series.

Solid plastic housing, 125mm dia. x117mm high. IP 54 enclosure protection.

For mounting, use KM1 plastic mounting bracket that comes with the device. With 5-metre measuring lead connected.

The KM1 plastic mounting bracket is also available as an individual (accessory) item.

Wind sensor WS

External control of actuators takes place by means of commercially available switches, momentary-contact switches, thermostats and, for particular applications, clock timers.

Eltako switches and momentary -contact switches that are one module =18mm wide and 55mm deep, are available for control in distribution boards and control panels as applicable, in particular the ZT12 dual momentary -contact switch for UP and DOWN central control.

On/Off switch A12, momentary-contact switch T12 and dual momentary-contactswitch for central control ZT12

Multi sensor MS EAN 4010312 901731 263,70 €/pc.

Light sensor LS EAN 4010312 901267 40,30 €/pc.

Wind sensor WS EAN 4010312 901281 50,40 €/pc.

On/Off switch

Momentary-contact switch

Dual momentary-contact switch

1 NO A12-100-16A

1 NO contact T12-100-16A-blue

1+1 NO contacts ZT12-200-16A-blue

EAN 4010312 700815

EAN 4010312 700846

EAN 4010312 700877

11,90 €/pc.

13,20 €/pc.

24,80 €/pc.

Recommended retail prices excluding VAT.

Page 82: Catalogo_Eltako_2009_ing

Multifunction sensor relay for brightness, twilight, wind, rain and frost, 5 OptoMOS semiconductor outputs 50mA/8..230V UC. Standby loss without Multi sensor MS 0.5 watt only.Modular device for DIN 50022 rail mounting.2 modules = 36mm wide, 58mm deep.The multi-sensor relay MSR12 evaluates the signals from the multisensor MS once per second, and sends appropriate control signals to the downstream EGS12Z or EGS12Z2 actuators depending on the setting of the rotary switch on the front. The OptoMOS semiconductor outputs switch the voltage applied to the universal voltage input terminal +B1. Only a single Multisensor MS can be connected to a Multifunction sensor relay MSR12. Several MSR12 can be connected to a multisensor MS, e.g. for evaluating up to three directions with the light sensor of the MS. Only a single MSR12 must provide the outer terminal resistance. It must be removed if there is a further MSR12. Supply voltage 24V DC from power unit WNT12-24V DC-6W (page I1). This power unit simultaneously supplies the multisensor MS connected to the terminals MS1, MS2, MSA and MSB, including heating of the rain sensor surface. After installation wait for the short automatic synchronisation of approx. 1 minute. During this process three LEDs fl ash in a slow sequence.Function rotary switchesBA = Setting the operating modes 1 to 10 from the adjacent table. 2 delay times RV - for wind and twilight - each in connection with 5 brightness ranges for light and twilight. The LED be-hind the rotary switch indicates Frost when the outdoor temperature drops below 2°C, at which point output 6 closes. This output opens again as soon as the temperature is over 3°C for 5 minutes.O-S-W = If the Multisensor MS is aligned towards the south, the weighting for light and twilight can be shifted towards the east or west. lf the MS is mounted in a different direction, the desired point of the compass can be set using this rotary switch. An LED behind the rotary switch indicates rain detection, at which point output 4 closes. Once the rain sensor surface dries out - assisted by a heating unit - contact 4 opens immediately. This is automatically followed by a 2-second pulse on output 2 if the sun signal is applied at that moment. m/s = This rotary switch is used to select the wind speed in metres per second at which the wind signal is triggered. This closes output 5. This is indicated by the LED behind the rotary switch. Opening takes place after the set delay time RV, during which the LED fl ashes. This is automatically followed by a 2-second pulse on output 2 if the sun signal is applied at that moment.DSR = In this position of the wind rotary switch the MSR12 functions like a twilight sensor relay. The twilight signal as described under Lux is then continuously applied to output 3 as long as the set twilight value is undershot. Output 3 opens with a delay of 5 minutes if the brightness value set is overshot. The outputs 4 (rain) and 6 (frost) remain active as described there. Output 5 (wind) likewise remain active, but the wind signal is triggered at 10m/s.TEST = As long as TEST remains switched on, each switchover from the OFF position to the TEST position activates the outputs 2 to 6 in ascending order.OFF = In the OFF position the MSR12 has no function.Lux = This rotary switch is used to set the brightness at which the sun signal is immediately triggered as a 2-second pulse at output 2. The LED behind the rotary switch indicates when the brightness value is exceeded. Lux = This rotary switch is used to set the brightness at which the 2-second twilight signal is triggered at output 3 after the set delay time RV when the value is undershot. This is indicated by the LED behind the rotary switch. It fl ashes during the delay time. If the twilight switching threshold is set to the same level or higher than the sun switching threshold, then the sun switching threshold is raised internally above the twilight switching threshold.Changing light compensation: Constant changes between sun and rain clouds would result in sensitive closing and opening of the shade elements. This is prevented by a changing light compensation function.Sensor function and open circuit monitoring: The Multisensor MS sends updated informa-tion to the MSR12 every second. If this signal is missing completely for 5 seconds, or if the individual signal from the wind sensor is missing for 24 hours, then an alarm is triggered: three LEDs fl ash rapidly and the wind output 5 is closed for 2 seconds in order to protect any awnings or windows which may be connected here. This pulse is repeated every hour. The alarm is turned off automatically when a signal is detected again.

Multifunction sensor relay MSR12

MSR12-8..230V UC

Function rotary switches

Standard setting ex factory.

H2

MSR12-8..230V UC 5 OptoMOS EAN 4010312 205327 87,40 €/pc.

Technical data page H7. Housing for operating instructions GBA12 page Z2.

Recommended retail prices excluding VAT.

Page 83: Catalogo_Eltako_2009_ing

Darstellung ist die Standard-einstellung ab Werk.

Light-twilight wind sensor relay, 3 OptoMOS semiconductor outputs 50mA. Standby loss 0.4 watt only.Modular device for DIN 50022 rail mounting.1 module =18mm wide, 58mm deep.

Supply voltage 8 to 230V UC.

The light-twilight wind sensor relay LDW12 evaluates the signals from the light sensor LS and the wind sensor WS and sends appropriate control signals to the downstream EGS12Z or EGS12Z2 actuators depending on the setting of the rotary switch on the front.

The Opto MOS semiconductor outputs switch the voltage applied to the universal voltage input terminal +B1.

Only a single light sensor LS and /or wind sensor WS can be connected to a sensor relay LDW12.

However, at a wind sensor WS several LDW12 can be connected for controlling different wind speeds. Then the LDW12 must be connected to the same potential +B1/-A2.

Function rotary switchesLux = This rotary switch is used to set the brightness 1klux-60 klux at which the sun signal is immediately triggered as a 2- second pulse at output 2. The LED behind the rotary switch indicates when the brightness value is exceeded.

Lux = This rotary switch is used to set the brightness 1klux-60 klux at which the 2-second twilight signal is triggered at output 3 after the set delay time of 15 minutes when the value is undershot. This is indicated by the LED behind the rotary switch. It fl ashes during the delay time. If the twilight switching threshold is set to the same level or higher than the sun switching threshold, then the sun switching threshold is raised internally above the twilight switching threshold.

m/s = This rotary switch is used to select the wind speed in metres per second at which the wind signal is triggered. This closes output 5. This is indicated by the LED behind the rotary switch. Opening takes place after the delay time of 5 minutes, during which the LED fl ashes. This is automatically followed by a 2-second pulse at output 2 if the sun signal is applied at that moment.

DSR = In this position of the wind rotary switch the LDW12 functions like a twilight sensor relay.The twilight signal as described under Lux is then continuously applied to output 3 as long as the set twilight value 20lux-2000lux is undershot. Output 3 opens with a delay of 5 minutes if the brightness value set at Lux is reached. Output 5 (wind) likewise remains active, but the wind signal is triggered at 10m/s.

TEST = As long as TEST remains switched on, each switchover from the OFF position to the TEST position activates the outputs 2, 3 and 5 and the corresponding LED fl ashes.

OFF = In the OFF position the LDW12 has no function.

Changing light compensationConstant changes between sun and rain clouds would result in sensitive closing and openingof the shade elements. This is prevented by a changing light compensation function.

Sensor function and open circuit monitoringIf the signal from the light sensor or the wind sensor is missing for 24 hours, then an alarm istriggered: the LED concerned fl ashes rapidly. Failure of the wind sensor results in a 1-secondpulse at output 5 in order to protect any awnings or windows which may be connected here.This pulse is repeated every hour. The alarm is turned off automatically when signals aredetected again.

LDW12-8..230V UC

Sensor relay LDW12

Function rotary switches

H3

Standard setting ex factory.

Technical data page H7. Housing for operating instructions GBA12 page Z2.

LDW12-8..230V UC 3 OptoMOS EAN 4010312 205259 65,30 €/pc.

Recommended retail prices excluding VAT.

Page 84: Catalogo_Eltako_2009_ing

Impulse group switch for central control, 1+1 NO contacts not potential free 16A/250V AC, for 1 motor or motor relays. Standby loss 0.4 watt only.Modular device for DIN 50022 rail mounting.1 module =18mm wide, 58mm deep.This impulse group switch serves to implement commands generated by the sensor relays or by switches and push-buttons and controls a motor, a motor isolating relay MTR12-8..230V UC or a DC motor relay DCM12-8..230V UC dependent on the setting of the rotary switch on the front. 8 to 230V UC supply voltage and switching voltage at terminals +B1/-A2. The control voltage at terminals A3 up to A8 must have an identical potential.The function of this electronic group impulse switch is based on the principle that, on the one hand, impulse control is used to obtain UP-Stop-DOWN-Stop (contact 1 closed - both contacts open - contact 2 closed - both contacts open) and, on the other hand, additional control inputs can be used to select UP or DOWN as desired. Dynamic refers to control inputs for which one impulse of not less than 20 milliseconds is suffi cient to close a contact. Static denotes a control input for which the contact is only closed as long as the control command is applied. UP and DOWN apply to roller shutters, Venetian blinds and roller blinds. For awnings, 'UP' = retract and 'DOWN' = extend. For windows 'UP' = open and 'DOWN' = close.Function rotary switchesAUTO 1 = When the lower rotary switch is in this position, the local advanced automatic reversing system for Venetian blinds is activated. When a push-button connected to A3+A4 (connected with a bridge) or A5/A6 connected to a dual push-button are used for local control a double impulse activates a slow rotation in the opposite direction, which can be stopped with a further impulse.AUTO 2 = When the lower rotary switch is in this position, the local advanced automatic reversing system for Venetian blinds is completely switched off.AUTO 3 = When the lower rotary switch is in this position, the local advanced automatic reversing system for Venetian blinds is switched off as well. The central control inputs A5 and A6 though, which are dynamic at AUTO 1 and AUTO 2, are static at fi rst, thus, allow reversal of Venetian blinds by operating push-buttons. They only switch to dynamic after 1 second continuous operation.

= (UP) and (DOWN) of the lower rotary switch are the positions for manual control. Manual control has priority over all other control commands.WA = Automatic reversal for Venetian blinds and awnings is controlled by means of the middle rotary switch. 0 = OFF, otherwise from 0.1 to 5 seconds ON with selected reversal time. In this case, it is only for DOWN that the direction is reversed on time-out of the time lag selected by means of the top rotary switch, e.g. to extend awnings or set Venetian blinds to a defined position.RV = The time delay (delay time RV) is set by means of the top rotary switch. If, the group impulse switch is in the UP or DOWN position the selected delay time runs (elapses); at time-out the device changes automatically to STOP. Therefore, the time delay must be chosen at least as long as the shading element or roller shutter will need to move from one limit position to the other. The LED indication for the delay times WA and RV is located behind this rotary switch.Local control with push-button connected to terminals A3+A4 (to be connected with a bridge). Each impulse causes the group impulse switch to change its position in the UP-Stop-DOWN-Stop sequence.Local control with roller shutter toggle switch connected to terminals A3 and A4.Local control with dual roller shutter push-button connected to A5 and A6. The 'UP' or 'DOWN' position is activated with an impulse by push-button. A further impulse from one of the two push-buttons stops the sequence immediately.Central control dynamic without priority connected to terminals A5 (UP) and A6 (DOWN). Up or DOWN is activated by a control signal. A further control signal (<700ms) at this control imput interrupts this process immediately, a further control signal (>700ms) continues the process. This is without priority because the local input A3+A4 (with bridge) and the central control inputs A7 and A8 can immediately override even whilst the control contact on A5 or A6 is still closed.Central control dynamic with priority connected to terminals A7 (UP) and A8 (DOWN). With priority because these control inputs cannot be overridden by other control inputs as long as the central control contact is closed. Otherwise it has the same function as the central control dynamic without priority. These central control inputs A7 and A8 are used for the sensor relays MSR12 and LDW12 for the wind sensor, the frost sensor and the rain sensor functions as these are required to have absolute priority over other sensor commands.

Actuator EGS12Z

EGS12Z-8..230V UC

H4

EGS12Z-8..230V UC 1+1 NO 16A EAN 4010312 107737 69,80 €/pc.

Technical data page H7. Housing for operating instructions GBA12 page Z2.

Standard setting ex factory.

Function rotary switches

Recommended retail prices excluding VAT.

Page 85: Catalogo_Eltako_2009_ing

Impulse group switch for central control, 2+2 NO contacts not potential free 5A /250V AC, for two 230V-motors. Standby loss 1 watt only.Modular device for DIN 50022 rail mounting. 2 modules = 36mm wide, 58mm deep.Supply voltage 8..230V UC at terminals +B1/-A2. The control voltage at terminals A3 up to A8 must have an identical potential.This impulse group switch serves to implement commands generated by the sensor relays or by switches and push-buttons and controls two 230V motors according to the setting of the rotary switches on the front.1/2 = motor 1, 3/4 = motor 2.The mode of operation corresponds completely to the impulse group switch EGS12Z on page H4 in which a MTR12 as described below is integrated.

EGS12Z2-8..230V UC

Actuators EGS12Z2, MTR12 and DCM12

H5

Motor isolating relay, 2+2 NO contacts not potential free 5A /250V AC for one or two 230V-motors. Standby loss 0.7 watt only.Modular device for DIN 50022 rail mounting.1 module =18mm wide, 58mm deep.

Universal control voltage 8..230V UC. 230V supply voltage.

The tube-mounted motors of shading elements and roller shutters must not be connected in parallel, or reverse voltages will occur through the limit switches, ultimately causing failure of the motors.

For one motor and if the control voltage and the motor voltage are 230V, one EGS12Z is adequate. Where more than one motor is controlled by an EGS12Z or in case the control voltage is different, one MTR12 must be connected to two motors. It must be remembered that the MTR12 devices, while they can be operated in parallel, require unassigned contact outputs K2/K3 of the controlling EGS12Z. These have to be connected to terminals K2/K3 of the MTR12.1/2 = motor 1, 3/4 = motor 2.

The functions UP and DOWN may be blocked or switched off entirely by a rotary switch. Thisblock applies only to the max. 2 connected motors. Therefore single shading elements or rollershutters can be completely or partially excepted from the automatic function of an over-all control.

MTR12-8..230V UC

MTR12-8..230V UC 2+2 NO 5A EAN 4010312 205211 57,80 €/pc.

EGS12Z2-8..230V UC 2+2 NO 5A EAN 4010312 108031 92,60 €/pc.

Function rotary switches

Technical data page H7. Housing for operating instructions GBA12 page Z2.

DC motor relay, 2 NO contacts not potential free 24V DC/90Watt, for one 24V DC motor. Standby loss 0.07 watt only.Modular device for DIN 50022 rail mounting.1 module =18mm wide, 58mm deep.

Universal control voltage 8..230V UC. 24V DC supply voltage.

The DCM12 can be operated in parallel, but they require unassigned contact outputs K2/K3 ofthe controlling EGS12Z. These have to be connected to terminals K2/ K3 of the DCM12.

The functions UP and DOWN may be blocked or switched off entirely by a rotary switch. Thisblock applies only to the 1 connected motor. Therefore single shading elements or roller shutterscan be completely or partially excepted from the automatic function of an over-all control.

DCM12-8..230V UC

DCM12-8..230V UC 2 NO 90W EAN 4010312 205310 57,80 €/pc.

MTR

12 a

nd D

CM12

Technical data page H7. Housing for operating instructions GBA12 page Z2.

Recommended retail prices excluding VAT.

Technical data page H7. Housing for operating instructions GBA12 page Z2.

Page 86: Catalogo_Eltako_2009_ing

H6

Impulse group switch for central control, 1 + 1 NO contacts not potential free 10A/250V AC, for one 230V AC motor.Standby loss 0.4 watt only.For installation and surface mounting. 45mm long, 55mm wide, 32mm deep. State-of-the-art hybrid technology combines advantages of nonwearing electronic control withhigh capacity of special relays.

This impulse group switch serves to implement commands generated by the sensor relays or by switches and push-buttons and controls a 230V motor for a shading element or a roller shutter.

230V control voltage, supply voltage and switching voltage.By using bistable relays coil power loss and heating is avoided even in the on mode.The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated.

By push-button at A1 impulse control is used to obtain UP-Stop-DOWN-Stop. Additional control inputs A7 and A8 can be used for central control UP or DOWN with priority.

A1, A7 and A8 need the same potential as L.

With priority because these control inputs cannot be overridden by other control inputs as long as the central control contact is closed. Up or DOWN is activated by a control signal. A further control signal (< 700ms) at this control imput interrupts this process immediately, a further control signal (> 700ms) continues the process.

The time delay (delay time RV) is set by means of the rotary switch RV. If, the group impulse switch is in the UP or DOWN position the selected delay time runs (elapses); at time-out the device changes automatically to STOP. Therefore, the time delay must be chosen at least as long as the shading element or roller shutter will need to move from one limit position to the other.

With the rotary switch WA automatic reversal is controlled: in the setting from 0.5 to 2 sec. reversal time the automatic reversal is activated. In this case, it is only for DOWN that the direction is reversed on time-out of the time lag selected by means of the top rotary switch RV, e.g. to extend awnings or set Venetian blinds to a defi ned position.

AUTO 1: No automatic reversal and no local advanced automatic reversing system.A7 and A8 operation < 1s static process (contact closes only during operation) operation > 1s dynamic process (contact remains closed), stop command by new operation.

AUTO 2: Automatic reversal with 1s reversal time. Additionally the local advanced automatic reversing system for Venetian blinds at A1 is active: a double impulse activates a slow rotation in the opposite direction, which can be stopped with a further impulse.

Actuator EGS61Z

EGS61Z-230V

EGS61Z-230V 1+1 NO 10A EAN 4010312 108123 53,50 €/pc.

Technical data page H7.

Recommended retail prices excluding VAT.

Standard setting ex factory.

Function rotary switches

Typical connection

cent

ral u

p

cent

ral d

own

Page 87: Catalogo_Eltako_2009_ing

Technical data shading systems and roller shutter control

If necessary, see the operating instructions of the appropriate shading elements for the maximum wind speed that can be set forthe sensor relays.

m/s 4 6 8 10 12 14 16

km/h 14.4 21.6 28.8 36.0 43.2 50.4 57.6

Bft 3 4 4 5 6 7 7

Do not route measurement leads parallel to other electrical lines - measurement leads must be screened statically if longer than 10m. For example JY-ST-Y. To extend leads use screw terminals and damp-proof connectors.

When selecting an installation site for light, wind and multi sensors, ensure that the sensors are not in the shadow of theobjects being monitored.

Contacts EGS12Z b) EGS12Z2 b) EGS61Z b) LDW12 /MSR12 1) MTR12 /DCM12

Contact material/contact gap AgSnO2 / 0.5 mm AgSnO2 / 0.5 mm AgSnO2 / 0.5 mm OptoMOS OptoMOS

Spacing of control connections/contact 3mm 3mm 3mm 3mm/6 mm 3mm

Test voltage as per VDE 0110control connection/contact

2000 V 2000 V 2000 VLDW12: 2000 VMSR12: 4000 V

2000 V

Rated switching capacity 16A /250V AC 5A /250V AC 10A /250V AC 50mA/8..230V UC5A /250V ACDCM: 90W

Inductive laod cos = 0.6 /230V AC 650W 650W 2) 400W – MTR12: 650W 2)

Life at rated load, cos = 0.6 >4x104 >4x104 >4x104 – >4x104

Switch position indication WA and RV WA and RV – LED LED

Terminal cross-section 2-fold /3-foldMaximum conductor cross-section 2-fold /3-fold

12mm2/7mm2

6mm2/4mm212mm2/7mm2

6mm2/4mm2 M312mm2/7mm2

6mm2/4mm212mm2/7mm2

6mm2/4mm2

Screw headslotted /Phillips, pozidriv

slotted /Phillips, pozidriv

slottedslotted /Phillips, pozidriv

slotted /Phillips, pozidriv

Shock-hazard protection (on the device)VDE 0106 part 100

VDE 0106 part 100

– VDE 0106 part 100VDE 0106 part 100

Electronics

Time on (also for central on/off) 100% 100% 100% 100% 100%

Max./min. temperature at mounting location +50°C/-20°C +50°C/-20°C +50°C/-20°C +50°C/-20°C +50°C/-20°C

Standby loss (active power) at 12 /24 /230V 0.05/0.1/0.4W 0.05/0.1/1W –/–/0.4WLDW: 0.05/0.1/0.4WMSR: –/0.5W/–

MTR12: 0.7WDCM12: 0.07W

Control current A1 or A3-A8 at 12/24/230V ±20% 0.05/0.11/0.7mA 0.05/0.11/0.7mA –/–/0.7mA – 0.1/0.2/1mA

Min. command duration 50 ms 50 ms 50 ms – –

b) Bistable relay as relay contact. Do not connect the switched consumer to the mains before the short automatic synchronisation after installation has terminated. 1) After installation and after a power failure the multisensor needs approx. 1 minute before the wind sensor is active. During this process the outputs wind

and sun of the MSR12 are blocked and 3 LEDs fl ash slowly. 2) Inductive load cos = 0.6 as sum of both contacts 1000W max.

Compliance with: EN 61000-6-3, EN 61000-6-1 and EN 60 669

H7

Page 88: Catalogo_Eltako_2009_ing

H8

Technische Daten Seite H6. Gehäuse für Bedienungs-anleitungen GBA12 Seite Z2.

LDW12-8..230V UC einschließlich GBA12 EAN 4010312 205259 65,30 EURO/St. Lagertype

For clarity, the L and N connections are not shown. Similarily, provision made for local control through A3 and A4 are not shown.

Typical circuit example of a shading system

Sens

or re

lays

UP DO

WN

Sens

ors

Actu

ator

s

EGS1

2ZEG

S12Z

EGS1

2ZEG

S12Z

1 ZT12

Mul

ti se

nsor

MS

3 2

+A3

+A5

+A4

+A7

+A6

+A8

-A2

K2K3

+B1

+A3

+A5

+A4

+A7

+A6

+A8

-A2

K2K3

+B1

+A3

+A5

+A4

+A7

+A6

+A8

-A2

K2K3

+B1

+A3

+A5

+A4

+A7

+A6

+A8

-A2

K2K3

+B1

Dua

l mom

enta

ry-

cont

act s

witc

h fo

r to

tal m

anua

l con

trol

of s

hadi

ng e

lem

ents

from smoke sensor (up)

L(+)

8-23

0V

UCN

(-)

MM

M

MM

MM

RainFrost

Sun

Twilight

Wind

Awni

ngs

cont

rol w

ith

sun

sens

or,

twili

ght s

enso

r, ra

in s

enso

r and

w

ind

sens

or

Vene

tian

blin

d co

ntro

l with

su

n se

nsor

, tw

iligh

t sen

sor,

rain

sen

sor a

nd

win

d se

nsor

Dor

mer

win

dow

co

ntro

l with

fro

st s

enso

r

Rolle

r blin

d co

ntro

l with

su

n se

nsor

and

tw

iligh

t sen

sor,

here

up

to 4

rolle

r blin

ds

in p

aral

lelM

TR12

N 12L

+K3

-A2

+K2

43

MTR

12

N 12L

+K3

-A2

+K2

43

WN

T12-

24V+

NL

MSR

12-8

..230

V UC

MS1

MS2

52

3

6 4

+B1

-24

V+2

4V

MSA

MSB

Whe

n co

ntro

lling

with

230

V (+

B1=

L, -

A2=

N)

the

230

V m

otor

s ar

e di

rect

ly c

onne

cted

to K

2, K

3 an

d N

. Oth

erw

ise

mot

or is

olat

ing

rela

ys M

TR12

mus

t be

inte

rcon

nect

ed

to K

2/K3

.

A ni

ght t

ime

win

dow

can

be

set w

ith th

e di

gita

l tim

e sw

itch

DW12

-001

-230

V so

that

the

mul

ti se

nsor

doe

s no

t cau

se a

ny d

istu

rban

ce. T

o do

this

, pro

gram

the

chan

geov

er

as fo

llow

s: in

the

dayt

ime

the

term

inal

+B1

of M

SR12

con

nect

to L

(+)

and

at n

ight

tim

e L(

+)

dire

ct to

term

inal

3 o

f MSR

12. T

his

sim

ulat

es tw

iligh

t at t

he b

egin

ning

of t

he

time

win

dow

in o

rder

to o

pen

all s

hadi

ng e

lem

ents

and

at t

he s

ame

time

all s

enso

rs a

re s

witc

hed

off.

With multifunction sensor relay MSR12

Page 89: Catalogo_Eltako_2009_ing

Typical circuit example of a shading system control and roller shutter control

When controlling with 230V (+B1= L, -A2=N) the 230V awning motor is directly connected to K2, K3 and N.Otherwise a motor isolating relay MTR12 must be interconnected to K2 /K3.

Shading system with the light, twilight and wind sensor relay LDW12

WS

LS

Twili

ght

Sun

Win

d

Sensor relaysSensors Actuators Sensor

Awnings control with sun sensor, twilight sensor and wind sensor

Local control with dual momentary-contact switch

UP

DOWN

LS GND WS

5

-A2

2 3

+B1

LDW

M

L(+)

N(-)8-230V UC

EGS12Z

+A3+A5+A4

+A7+A6+A8

-A2

K2 K3

+B1

For clarity, the L and N connections for the 230V motors are not shown.

Roller shutter control with EGS12Z2

8-230V UC

centraldown

UP UP

up

DOWN DOWN

N L

3 4

1 2

N L

3 4

1 2

N L

3 4

1 2

M M M

Local control with dual-roller shutter momentary contactswitch

Local control withroller shutter toggle switch

Local control withpush-button

H9

Page 90: Catalogo_Eltako_2009_ing

H10

Technische Daten Seite H6. Gehäuse für Bedienungs-anleitungen GBA12 Seite Z2.

LDW12-8..230V UC einschließlich GBA12 EAN 4010312 205259 65,30 EURO/St. Lagertype

For clarity, the L and N connections for the 230V motors are not shown.

Typical circuit examples of a roller shutter control

Dua

l mom

enta

ry-c

onta

ct s

witc

h fo

r cen

tral c

ontro

l UP

and

DO

WN

Loca

l con

trol w

ith

dual

rolle

r shu

tter

mom

enta

ry-c

onta

ct s

witc

h

Loca

l con

trol w

ith

rolle

r shu

tter t

oggl

e sw

itch

Loca

l con

trol w

ith

push

-but

ton;

her

e up

to

4 ro

ller s

hutte

rs in

par

alle

l

UP DOW

N

UP DOW

N

L(+)

N(-)

8-23

0V

UC

EGS1

2Z

+A3

+A5

+A4

+A7

+A6

+A8

-A2

K2K3

+B1

UP DOW

NEG

S12Z

+A3

+A5

+A4

+A7

+A6

+A8

-A2

K2K3

+B1

EGS1

2Z

+A3

+A5

+A4

+A7

+A6

+A8

-A2

K2K3

+B1

N 12L

+K3

-A2

+K2

43

ZT12

1 23

N 12L

+K3

-A2

+K2

43

MM

MTR

12M

TR12

MM

MM

Usin

g a

wee

k tim

e sw

itch

with

1 C

O th

e ro

ller s

hutte

r con

trol c

an b

e au

tom

ated

tim

e-de

pend

ent b

y pr

ogra

mm

ing

the

chan

geov

er a

s fo

llow

s: in

the

dayt

ime

term

inal

+A3

m

ust b

e co

nnec

ted

to L

(+)

and

at n

ight

tim

e sw

itchi

ng o

ver t

o +

A4. A

ll ot

her c

ontro

l inp

uts

exce

pt th

e lo

cal c

ontro

l with

a p

ush-

butto

n st

ay a

ctiv

e fo

r loc

al a

nd c

entra

l co

ntro

l.

Usin

g th

e lig

ht, t

wili

ght a

nd w

ind

sens

or re

lay

LDW

12-8

..230

V UC

the

rolle

r shu

tter c

ontro

l can

be

auto

mat

ed b

right

ness

-dep

ende

nt b

y co

nnec

ting

term

inal

+A5

of t

he

EGS1

2Z to

the

outp

ut 2

of t

he L

DW

12 a

nd te

rmin

al +

A6 w

ith th

e ou

tput

3. A

ll ot

her c

ontro

l inp

uts

stay

act

ive

for l

ocal

and

cen

tral c

ontro

l.

Roller shutter control with EGS12Z

Page 91: Catalogo_Eltako_2009_ing

The

bet

ter

cho

ice

Wide-range switching power supply units

Wide-range switching power supply units WNT12 6, 12 and 24W I0Wide-range switching power supply units WNT12 48W and technical data I1

I

Page 92: Catalogo_Eltako_2009_ing

Wide-range switching power supply units WNT12

Rated capacity 6W. Standby loss 0.2 watt only.Modular devices for DIN 50022 rail mounting.1 module =18mm wide, 58mm deep.

Even at full load a ventilation clearance is not neccessary.Wide-range input voltage 88-264V (110V -20% up to 240V +10%).Effi ciency 12V DC 83%, 24V DC 86%. Stabilised output voltage ±1%, low residual ripple. Short-circuit proof.

Overload protection and over-temperature switch-off by means of switching off with automaticswitching-on after fault clearance (autorecovery function).

WNT12-12V DC-6W/0,5A and WNT12-24V DC-6W/0,25A

I0 Rated capacity 12W. Standby loss 0.2 watt only.Modular devices for DIN 50022 rail mounting.1 module =18mm wide, 58mm deep.

At a load of more than 50% of the rated capacity and always if there are adjacent switchingpower supply units from 12W rated capacity and if there are dimmers a ventilation clearanceof 1/2 module must be maintained with the spacers DS12 on both sides.

Wide-range input voltage 88-264V AC (110V -20% bis 240V +10%). Effi ciency 12V DC 83%, 24V DC 86%. Stabilised output voltage ±1%, low residual ripple. Short-circuit proof.

Overload protection and over-temperature switch-off by means of swichting off with automatic switching-on after fault clearance (autorecovery function).

WNT12-12V DC-12W/1A and WNT12-24V DC-12W/0,5A

WNT12-12V DC-6W/0,5AWNT12-24V DC-6W/0,25A

EAN 4010312 300091EAN 4010312 300107

49,70 €/pc.49,70 €/pc.

WNT12-12V DC-12W/1AWNT12-24V DC-12W/0,5A

EAN 4010312 901748EAN 4010312 901755

59,90 €/pc.59,90 €/pc.

Recommended retail prices excluding VAT.

The better choicePower supply units can be high power consumers - but not the modern wide-range switching power supply units from ELTAKO: the standby loss for the 6, 12 and 24W models is only 0.2 watt!An important factor governing the output of power supply units is effi ciency. Here you can expect peak values of 83% to 87% from our products.

Page 93: Catalogo_Eltako_2009_ing

Wide-range switching power supply units WNT12

Rated capacity 48W. Standby loss 0.4 watt only.Modular devices for DIN 50022 rail mounting.4 modules = 72mm wide, 58mm deep.

At a load of more than 50% of the rated capacity and always if there are adjacent switchingpower supply units from 12W rated capacity and if there are dimmers a ventilation clearanceof 1/2 module must be maintained with the spacers DS12 on both sides.

Wide-range input voltage 88-264V AC (110V -20% bis 240V +10%). Effi ciency 87%. Stabilised output voltage ±1%, low residual ripple. Short-circuit proof.

Overload protection and over-temperature switch-off by means of switching off with automaticswitching-on after fault clearance (autorecovery function).

WNT12-24V DC-48W/2A

I1

WNT12-24V DC-48W/2A EAN 4010312 300114 116,70 €/pc.

Rated capacity 24W. Standby loss 0.2 watt only.Modular devices for DIN 50022 rail mounting.2 modules = 36mm wide, 58mm deep.

At a load of more than 50% of the rated capacity and always if there are adjacent switchingpower supply units from 12W rated capacity and if there are dimmers a ventilation clearanceof 1/2 module must be maintained with the spacers DS12 on both sides.

Wide-range input voltage 88-264V AC (110V -20% bis 240V +10%). Effi ciency 12V DC 83%, 24V DC 87%. Stabilised output voltage ±1%, low residual ripple. Short-circuit proof.

Overload protection and over-temperature switch-off by means of swichting off with automatic switching-on after fault clearance (autorecovery function).

WNT12-12V DC-24W/2A and WNT12-24V DC-24W/1A

WNT12-12V DC-24W/2AWNT12-24V DC-24W/1A

EAN 4010312 300077EAN 4010312 300084

77,80 €/pc.77,80 €/pc.

Recommended retail prices excluding VAT.

Page 94: Catalogo_Eltako_2009_ing

I2

Technical data

TypeWNT12-12V DC-

6W/0,5AWNT12-24V DC-

6W/0,25AWNT12-12V DC-

12W/1AWNT12-24V DC-

12W/0,5AWNT12-12V DC-

24W/2AWNT12-24V DC-

24W/1AWNT12-24V DC-

48W/2A

Output wattage 6W 1) 6W 1) 12W 2) 12W 2) 24W 2) 24W 2) 48W 2)

Output voltage,tolerance ±

12V DC, ±1% 24V DC, ±1% 12V DC, ±1% 24V DC, ±1% 12V DC, ±1% 24V DC, ±1% 24V DC, ±1%

Output current 0.5A 0.25A 1A 0.5A 2A 1A 2A

Standby loss 0.2W 0.2W 0.2W 0.2W 0.2W 0.2W 0.4W

Residual ripple 100mV 100mV 100mV 100mV 100mV 100mV 100mV

Supply voltage88-264V AC120-370V DC

88-264V AC120-370V DC

88-264V AC120-370V DC

88-264V AC120-370V DC

88-264V AC120-370V DC

88-264V AC120-370V DC

88-264V AC120-370V DC

Insolation class II II II II II II II

Class of protection IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20

Starting current 3) 18A/230V 18A/230V 18A/230V 18A/230V 18A/230V 18A/230V 18A/230V

Effi ciency 83% 86% 83% 86% 83% 87% 87%

Overload protectionshort-term

160-200% 160-200% 160-200% 160-200% 160-200% 160-200% 160-200%

Overvoltage protection 140-170% 140-170% 140-170% 140-170% 140-170% 140-170% 140-170%

Short-circuit proof 4) yes yes yes yes yes yes yees

Over-temperature protection 4) yes yes yes yes yes yes yes

Switchable in parallel,number 2 2 2 2 2 2 –

Size1 module,18mm

1 module,18mm

1 module,18mm

1 module,18mm

2 modules,36mm

2 modules,36mm

4 modules,72mm

Operating temperature °C -10/+50 -10/+50 -10/+50 -10/+50 -10/+50 -10/+50 -10/+50

1) Even at full load a ventilation clearance is not neccessary. 2) At a load of more than 50% of the rated capacity and always if there are adjacent switching power supply units from 12W rated capacity and if there are

dimmers a ventilation clearance of 1/2 module must be maintained with the spacers DS12 on both sides. 3) If connected on the primary side, 2ms. 4) With autorecovery function after fault clearance.

Compliance with: EN 60 950, EN 55 022 and EN 61000-6-2

Page 95: Catalogo_Eltako_2009_ing

Pole

Pos

itio

n S

Switching on the future.

Electromechanical impulse switches

1- and 2-pole impulse switches S09 and S12 J2Impulse multicircuit switch SS12, 4-pole impulse switches 16A S12 and auxiliary contact KM12 J3Impulse switches, impulse multicircuit switch and impulse group switch S91, S81, SS81 and GS81 J41-, 2- and 4-pole impulse switches 25A XS12 J5Terminal connections J6Technical data J7

J

Page 96: Catalogo_Eltako_2009_ing

Impulse switches with 1 and 2 contacts S09 and S12

1 NO contact 16A/230V ACModular devices for DIN 50 022 rail mounting with manual control and switch position indicator. Only ½ module = 9mm wide, 55mm deep.

Control power demand 5W. For impulse control.

Contact gap 3mm.

S09-

1-pole and 2-pole 16A/250V ACModular devices for DIN 50 022 rail mounting with manual control and switch position indicator.1 module = 18mm wide, 55mm deep.

100% time on. Control power demand 5-6W only.

Contacts 1 NO, 2 NO, 1 NO + 1 NC.Contact gap 3mm. Spacing of control connections/contact > 6mm. For control voltages up to 48V AC and 110V DC suitable for SELV net.

4-pole devices S12, page J3 and devices for 25A XS12, page J5.Retrofi ttable auxiliary contact KM12, page J3.* Non-standard control voltages: 42, 48, 60 and 110V/50Hz or 110, 115, 127 and 220V/60Hz as well as 6, 8, 42, 48, 60, 110 and 220V DC.

The terminal compatible hybrid impulse switches ES12DX-UC, ES12-200-8..230V UC and ES12-110-8..230V UC may be used as well.

S12-100-/200-/110-

J2

S09-12VS09-230VS09-8V, 24V, 12V DC, 24V DC

1 NO 16A1 NO 16A1 NO 16A

EAN 4010312 104187EAN 4010312 104200

22,10 €/pc.22,10 €/pc.23,80 €/pc.

Pole Position SWhen we introduced the fi rst ELTAKO impulse switches in 1949, they were already standing in the pole position in Europe and since then we have defended this position time and again with innovative products, highest quality, best possible service and attractive prices. Then, impulse switches were also called impulse relays, step switches or latching relays.

S12-100-12VS12-100-230VS12-100-8V, 24V, 12V DC, 24V DCS12-100-*

S12-200-12VS12-200-230VS12-200-8V, 24V, 12V DC, 24V DCS12-200-*

S12-110-12VS12-110-230VS12-110-8V, 24V, 12V DC, 24V DCS12-110-*

1 NO 16 A1 NO 16 A1 NO 16 A1 NO 16 A

2 NO 16 A2 NO 16 A2 NO 16 A2 NO 16 A

1 NO + 1 NC 16 A1 NO + 1 NC 16 A1 NO + 1 NC 16 A1 NO + 1 NC 16 A

EAN 4010312 100455EAN 4010312 100479

EAN 4010312 100530EAN 4010312 100554

EAN 4010312 100493EAN 4010312 100516

21,30 €/pc.21,30 €/pc.23,00 €/pc.24,70 €/pc.

26,70 €/pc.26,70 €/pc.28,50 €/pc.30,60 €/pc.

26,70 €/pc.26,70 €/pc.28,50 €/pc.30,60 €/pc.

Technical data page J7.

Technical data page J7.S09-230V

S12-100-230V

Recommended retail prices excluding VAT.

Page 97: Catalogo_Eltako_2009_ing

Impulse multicircuit switch SS12, 4-pole 16A impulse switches S12 and auxiliary contact KM12

4-pole 16A /250V ACModular devices for DIN 50 022 rail mounting with manual control and switch position indicator, for impulse control.2 modules = 36mm wide, 55mm deep.Time on: impulse control only. Control power demand 12-15W.Contacts: 4 NO, 3 NO + 1 NC, 2 NO + 2 NC. Contact gap 3mm.Devices for 25A XS12, page J5.Retrofi ttable auxiliary contact KM12.* Non-standard control voltages: 8, 12, 24, 42, 48, 60, 110V/50Hz or 110, 115, 127 and 220V/60Hz as well as 6, 8, 12, 24, 42, 48, 60, 110 and 220V DC.

S12-400-/310-/220-

Technical data page J7.

Contact module, 1 NO contact and 1 NC contact 4A /250V ACRetrofi ttable to the left of all impulse switches S12 and XS12 as well as switching relays andinstallation contactors R12, XR12 and VR12.

½ module = 9mm wide, 55mm deep.

KM12

J3

Technical data page J7.

Impulse multicircuit switch, 1+1 NO contacts 16A /250V ACModular devices for DIN 50 022 rail mounting with manual control and switch position indicator.1 module = 18mm wide, 55mm deep.100% time on. Control power demand 5-6W.Contact gap 3mm. Spacing of control connections/contact > 6mm. For control voltages up to 48V AC and 110V DC suitable for SELV net.* Non-standard control voltages: 8, 24, 42, 48, 60, 110V/50Hz or 110, 115, 127 and 220V/60Hz as well as 6, 8, 12, 24, 42, 48, 60, 110 and 220V DC.The hybrid impulse switch ESR12M-8..230V UC may be used as well.

SS12-110-

Technical data page J7.SS12-110-230V

S12-220-230V

SS12-110-12VSS12-110-230VSS12-110-*

1 + 1 NO 16A1 + 1 NO 16A1 + 1 NO 16A

EAN 4010312 101346EAN 4010312 101124

27,70 €/pc.27,70 €/pc.31,80 €/pc.

S12-400-230VS12-400-*

S12-310-230VS12-310-*

S12-220-230VS12-220-*

4 NO 16A4 NO 16A

3 NO + 1 NC 16A3 NO + 1 NC 16A

2 NO + 2 NC 16A2 NO + 2 NC 16A

EAN 4010312 104484

EAN 4010312 100639

EAN 4010312 100592

40,70 €/pc.46,80 €/pc.

40,70 €/pc.46,80 €/pc.

40,70 €/pc.46,80 €/pc.

KM12 Auxiliary contact 1 NO + 1 NC, 4A

EAN 4010312 901243 13,20 €/pc.

Recommended retail prices excluding VAT.

Page 98: Catalogo_Eltako_2009_ing

* Non-standard control voltages: 8, 24, 42, 48, 60 and 110V/50Hz or 110, 115, 127 and 220V/60Hz as well as 6, 8, 12, 24, 42, 48, 60, 110 and 220V DC. SS81 and GS81 also 12V and 230V/50Hz.

Impulse switches with 1 and 2 contacts S91, S81, SS81 and GS81

1 NO contact 10A /250V ACBuilt-in devices for installation and surface mounting. With manual control and switch position indicator. 50mm long, 26mm wide, 32mm deep.Time on 100%. Control power demand 4-5W. Contact gap 2mm.The hybrid impulse switch ES61-8..230V UC may be used as well.

S91-100-

J4

1 or 2 CO contacts 10A /250V ACBuilt-in devices for installation and surface mounting. With manual control and switch position indicator. 50mm long, 42mm wide, 32mm deep. Time on 100%. Control power demand 5-5.5W. Contact gap 2mm.In applications with 1CO without glowlamp current the hybrid impulse switchESR61M-8..230V UC may be used as well.

S81-001-/002-

S81-001-12VS81-001-230VS81-001-*S81-002-12VS81-002-230VS81-002-*

1 CO 10A1 CO 10A1 CO 10A2 CO 10A2 CO 10A2 CO 10A

EAN 4010312 103470EAN 4010312 103494

EAN 4010312 103319EAN 4010312 103333

21,90 €/pc.21,90 €/pc.25,40 €/pc.26,70 €/pc.26,70 €/pc.30,60 €/pc.

Multicircuit switch 1+1 CO contacts 10A /250V ACBuilt-in device for installation and surface mounting. With manual control and switch position indicator. 50mm long, 42mm wide, 32mm deep. Time on 100%. Control power demand 5-5.5W. Contact gap 2mm.In applications with 1+1 NO without glowlamp current the hybrid impulse switchESR61M-8..230V UC may be used as well.

SS81-002-

SS81-002-* 1+1 CO 10A 31,80 €/pc.

Group switch 1 + 1 CO contact 10A /250V ACBuilt-in device for installation and surface mounting. With manual control and switch position indicator. 50mm long, 42mm wide, 32mm deep. Time on 100%. Control power demand 5-5.5W only. Contact gap 2mm.In applications with 1+1 NO without glowlamp current the hybrid impulse switchESR61M-8..230V UC may be used as well.

GS81-002-

GS81-002-* 1 + 1 CO 10A 31,80 €/pc.

Technical data page J7. Mounting accessory page Z1.

Technical data page J7. Mounting accessory page Z1.

Technical data page J7. Mounting accessory page Z1.

Technical data page J7. Mounting accessory page Z1.

S91-100-230V

S81-002-230V

SS81-002-230V

GS81-002-12V

S91-100-12VS91-100-230VS91-100-*

1 NO 10A1 NO 10A1 NO 10A

EAN 4010312 103517EAN 4010312 103531

22,00 €/pc.22,00 €/pc.25,60 €/pc.

Recommended retail prices excluding VAT.

Page 99: Catalogo_Eltako_2009_ing

1-, 2- and 4-pole 25A impulse switches XS12

1-pole and 2-pole, 25A /250V ACModular devices for DIN 50 022 rail mounting with manual control and switch position indicator. 1 module = 18mm wide, 55mm deep.

100% time on. Control power demand 5-6W.

Contacts: 1 NO, 2 NO, 1 NO + 1 NC.Contact gap 3mm.

Retrofi ttable auxiliary contact KM12, page J3.

Technical data page J7.

XS12-100-/200-/110-

J5

4-pole 25A /250V ACModular devices for DIN 50 022 rail mounting with manual control and switch position indicator, for impulse control. 2 modules = 36mm wide, 55mm deep.

Time on: impulse control only. Control power demand 12-15W.

Contacts: 4 NO, 3 NO + 1 NC, 2 NO + 2 NC.

Contact gap 3mm.

Retrofi ttable auxiliary contact KM12, page J3.

Technical data page J7.

XS12-400-/310-/220-

XS12-110-230V

XS12-400-230V

XS12-400-12VXS12-400-24VXS12-400-230VXS12-400-12V DCXS12-400-24V DCXS12-310-12VXS12-310-24VXS12-310-230VXS12-310-12V DCXS12-310-24V DCXS12-220-12VXS12-220-24VXS12-220-230VXS12-220-12V DCXS12-220-24V DC

4 NO 25A4 NO 25A4 NO 25A4 NO 25A4 NO 25A

3 NO + 1 NC 25A3 NO + 1 NC 25A3 NO + 1 NC 25A3 NO + 1 NC 25A3 NO + 1 NC 25A

2 NO + 2 NC 25A2 NO + 2 NC 25A2 NO + 2 NC 25A2 NO + 2 NC 25A2 NO + 2 NC 25A

EAN 4010312 101636EAN 4010312 101643EAN 4010312 101650EAN 4010312 103036EAN 4010312 101667

EAN 4010312 101681EAN 4010312 101698EAN 4010312 101704 EAN 4010312 104408EAN 4010312 101711

EAN 4010312 101735EAN 4010312 101742EAN 4010312 101759EAN 4010312 103029EAN 4010312 101766

46,30 €/pc.46,30 €/pc.40,70 €/pc.46,30 €/pc.46,30 €/pc.46,30 €/pc.46,30 €/pc.40,70 €/pc.46,30 €/pc.46,30 €/pc.46,30 €/pc.46,30 €/pc.40,70 €/pc.46,30 €/pc.46,30 €/pc.

XS12-100-12VXS12-100-24VXS12-100-230VXS12-100-12V DCXS12-100-24V DCXS12-200-12VXS12-200-24VXS12-200-230VXS12-200-12V DCXS12-200-24V DCXS12-110-12VXS12-110-24VXS12-110-230VXS12-110-12V DCXS12-110-24V DC

1 NO 25A1 NO 25A1 NO 25A1 NO 25A1 NO 25A

2 NO 25A2 NO 25A2 NO 25A2 NO 25A2 NO 25A

1 NO + 1 NC 25A1 NO + 1 NC 25A1 NO + 1 NC 25A1 NO + 1 NC 25A1 NO + 1 NC 25A

EAN 4010312 101490EAN 4010312 101506EAN 4010312 101513EAN 4010312 104354EAN 4010312 101476

EAN 4010312 101582EAN 4010312 101599EAN 4010312 101605EAN 4010312 104392EAN 4010312 101612

EAN 4010312 101537EAN 4010312 101544EAN 4010312 101551EAN 4010312 104385EAN 4010312 101568

27,00 €/pc.27,00 €/pc.25,10 €/pc.27,00 €/pc.27,00 €/pc.32,20 €/pc.32,20 €/pc.29,60 €/pc.32,20 €/pc.32,20 €/pc.32,20 €/pc.32,20 €/pc.29,60 €/pc.32,20 €/pc.32,20 €/pc.

Recommended retail prices excluding VAT.

Page 100: Catalogo_Eltako_2009_ing

Switch positions of electromechanical impulse switchesComparable electronic types

Contacts Type Contacts Type

J6

1 NO contact S09-S12-100-XS12-100-S91-100-

0

1-2

0

1-2

S12-200-XS12-200-

2 NO contacts

0

1-23-4

0

1-23-4

1 NO contact +1 NC contact

S12-110-XS12-110-

1-2

3-4

1-2

3-4

Multicircuit switch1+1 NO contacts

SS12-110-

0

1-2

1-23-4

3-4

4 NO contacts S12-400-XS12-400-

0

1-23-45-67-8

0

1-23-45-67-8

3 NO contacts+1 NC contact

S12-310-XS12-310-

1-23-45-6

7-8

1-23-45-6

7-8

2 NO contacts+2 NC contacts

S12-220-XS12-220-

1-25-6

3-47-8

1-25-6

3-47-8

1 CO contact S81-001

1-2

1-3

1-21-3

1+1 CO contacts

1-24-5

1-34-5

1-34-6

1-24-6 SS81-002-

1+1 CO contacts GS81-002-

1-24-5

1-34-5

1-24-5

1-24-6

2 CO contacts S81-002

4-5 1-2

4-6 1-3

4-5 1-2

4-6 1-3

Comparable electronic types

ES12DX-UC (formerly ES12-100-8..230V UC) replaces terminal compatible the S12-100-, all control voltages

ES12-200-8..230V UC replaces terminal compatible the S12-200-, all control voltages

ES12-110-8..230V UC replaces terminal compatible the S12-110-, all control voltages

ESR12M-8..230V UC replaces the SS12-110-, all control voltages

ES61-8..230V UC replaces the S91-100-, all control voltages

ESR61M-8..230V UC replaces partially S81-, SS81- and GS81-, all control voltages

Page 101: Catalogo_Eltako_2009_ing

Technical data electromechanical impulse switches

J7

ContactsXS12 S09/S12 S91/S81/SS81/GS81

Contact material /contact gap AgSnO2/ 3mm 1) AgSnO2/ 3mm AgSnO2/ 2mm

Spacing of control connections/contact > 6 mm > 6 mm > 6 mm

Test voltage contact/contactTest voltage control connections/contact

2000 V4000 V

2000 V4000 V

2000 V4000 V

Rated switching capacity25A/250 V AC 16 A/400 V AC

16A/250 V AC 10A/400 V AC

10 A/250 V AC6A/400 V AC

Fluorescent lamp load with KVG* shunt-compensated or with EVG*

1000 VA 500 VA 500 VA

Compact fl uorescent lamps with EVG*and energy saving lamps ESL I on 140 A/10 ms 2) I on 140 A/10 ms 2) I on 70 A/10 ms 2)

HQL and HQI non compensated 500 W 500 W –

Max. switching current DC1: 12V/24V DC 12A 8A 8A

Life at rated load cos = 1 or incandescent lamps 1000 W at 100/h

> 10 5 > 10 5 > 10 5

Life at rated load,cos = 0.6 at 100/h

> 4 x104 > 4 x104 > 4 x104

Max. operating cycles 103/h 103/h 103/h

Switch position indication yes yes yes

Manual control yes yes yes

Terminal cross-section 12 mm2 12 mm2 6 mm2

Maximum conductor cross-section 6 mm2 6 mm2 2.5 mm2

Screw head slotted/Phillips, pozidriv slotted/Phillips, pozidriv slotted/Phillips, pozidriv

Shock-hazard protection (on the device) VDE 0106 part 100 VDE 0106 part 100 VDE 0106 part 100

Solenoid

Time on at rated voltage 1- and 2-pole, without S09 100% 3) 100% 3) 100% 3)

Time on at rated voltage 4-pole as well as S09 impulse control impulse control –

Max./min. temperature at mounting location +50°C/-5°C +50°C/-5°C +50°C/-5°C

Control voltage range 0.9 to 1.1 x rated voltage 0.9 to 1.1 x rated voltage 0.9 to 1.1 x rated voltage

Coil power loss AC+ DC ±20%1- and 2-pole 5 - 6W;3- and 4-pole 12 - 15W

1- and 2-pole 5 - 6W;3- and 4-pole 12 - 15W

5W

Min. command duration 50ms 50ms 50ms

Max. parallel capacitance (length) of single control lead at 230V AC

0.06μF (approx. 200m) 0.06μF (approx. 200m) 0.06μF (approx. 200m)

Max. voltage induced at the control inputs 0.2 x rated voltage 0.2 x rated voltage 0.2 x rated voltage

Glow lamps in parallel with the 230V control switches 5mA 5mA 5mA

With 1μF/250V AC capacitor in parallel with coil 10 mA 10 mA 10 mA

With 2.2μF/250V AC capacitor in parallel with coil 15mA 15mA 15mA

Compliance with: EN 60 669

1) Contact spacing of NC contacts 1.2mm. 2) A 40-fold inrush current must be calculated for electronic ballast devices. For steady loads of 1200W or 600W use the current-limiting relay SBR12 or

SBR61. Product group G, page G3. 3) Whenever several impulse switches are continuously energised make sure there is adequate ventilation as a function of the calculated power loss and,

in addition, a ventilation clearance of approx. half a module. Use the DS12 spacer as necessary.

*EVG = electronic ballast units; KVG = conventional ballast units

Page 102: Catalogo_Eltako_2009_ing

Pole

Pos

itio

n R

Switching on the future.

Electromechanical switchingrelays and installation contactors

Switching relays R12 K2Switching relays R91 and R81 K3Installation contactors 25A XR12 K4Technical data K5

K

Page 103: Catalogo_Eltako_2009_ing

1-, 2- and 4-pole electromechanical switching relays R12

K2

1- and 2-pole, 16A/250V ACModular devices for DIN 50022 rail mounting with manual control and switch position indicator. 1 module = 18mm wide, 55mm deep.

100% time on. Control power demand 1.9W.

Contacts: 1 NO, 2 NO, 1 NO a+ 1 NC, 2 NC (closed-circuit current relay, 230V only).Contact gap 3mm.

Contact /contact test voltage 2000V and control connections/contact test voltage 4000V.

25A devices XR12, page K4. Retrofi ttable auxiliary contact KM12, page J3.

* Non-standard control voltages: 42, 48, 60, 110V/50Hz or 110, 115, 127 and 220V/60Hz as well as 6, 8, 42, 48, 60, 110 and 220V DC.

R12-100-/200-/110-/020-230V

R12-100-12VR12-100-230VR12-100-8V, 24V, 12V DC, 24V DCR12-100-*

R12-200-12VR12-200-230VR12-200-8V, 24V, 12V DC, 24V DCR12-200-*

R12-110-12VR12-110-230VR12-110-8V, 24V, 12V DC, 24V DCR12-110-*

R12-020-230V

1 NO 16A1 NO 16A1 NO 16A1 NO 16A

2 NO 16 A2 NO 16 A2 NO 16 A2 NO 16 A

1 NO + 1 NC 16A1 NO + 1 NC 16A1 NO + 1 NC 16A1 NO + 1 NC 16A

2 NC 16A

EAN 4010312 200421EAN 4010312 200445

EAN 4010312 200506EAN 4010312 200520

EAN 4010312 200469EAN 4010312 200483

EAN 4010312 201572

21,30 €/pc.21,30 €/pc.23,00 €/pc.24,70 €/pc.

26,70 €/pc.26,70 €/pc.28,50 €/pc.30,60 €/pc.

26,70 €/pc.26,70 €/pc.28,50 €/pc.30,60 €/pc.

26,70 €/pc.

4-pole, 16A /250V ACModular devices for DIN 50022 rail mounting with manual control and switch position indicator. 2 modules = 36mm wide, 55mm deep.

100% time on. Control power demand 4W.

Contacts: 4 NO, 3 NO + 1 NC, 2 NO + 2 NC.Contact gap 3mm.

Contact/contact test voltage 2000V and control connections/contact test voltage 4000V.

25A devices XR12, page K4. Retrofi ttable auxiliary contact KM12, page J3.

* Non-standard control voltages: 8, 12, 24, 42, 48, 60 and 110V/50Hz or 110, 115, 127 and 220V/60Hz as well as 6, 8, 12, 24, 42, 48, 60, 110 and 220V DC.

R12-400-/310-/220-

R12-400-230VR12-400-*

R12-310-230VR12-310-*

R12-220-230VR12-220-*

4 NO 16A4 NO 16A

3 NO + 1 NC 16A3 NO + 1 NC 16A

2 NO + 2 NC 16A2 NO + 2 NC 16A

EAN 4010312 200643

EAN 4010312 200605

EAN 4010312 200568

40,70 €/pc.46,80 €/pc.

40,70 €/pc.46,80 €/pc.

40,70 €/pc.46,80 €/pc.

Recommended retail prices excluding VAT.

Technical data page K5.

Technical data page K5.

R12-110-230V

R12-400-230V

Page 104: Catalogo_Eltako_2009_ing

1- or 2-pole electromechanical switching relays R91 and R81

1 NO contact 10A /250V ACBuilt-in devices for installation and surface mounting. 50mm long, 26mm wide, 32mm deep.

Time on 100%. Control power demand 2.5W.

Contact gap 2mm.

Contact /contact test voltage 2000V and control connection/contact test voltage 4000V.

* Non-standard control voltages: 8, 24, 42, 48, 60 and 110V/50Hz or 110, 115, 127 and 220V/60Hz as well as 6, 8, 12, 24, 42, 48, 60, 110 and 220V DC.

R91-100-

1 or 2 CO contacts 10A /250V ACBuilt-in devices for installation and surface mounting.50mm long, 42mm wide, 32mm deep.

Time on 100%. Control power demand 5-5.5W.

Contact gap 2mm.

Contact /contact test voltage 2000V and control connection/contact test voltage 4000V.

* Non-standard control voltages: 8, 24, 42, 48, 60 and 110V/50Hz or 110, 115, 127 and 220V/60Hz as well as 6, 8, 12, 24, 42, 48, 60, 110 and 220V DC.

R81-001-/002-

Technical data page K5.

Technical data page K5.

Comparable electronic types

Recommended retail prices excluding VAT.

K3

ER12DX-UC (formerly ER12-100-8..230V UC) replaces terminal compatible the R12-100-, all control voltages

ER12-200-8..230V UC replaces terminal compatible the R12-200-, all control voltages

ER12-110-8..230V UC replaces terminal compatible the R12-110-, all control voltages

ER61-8..230V UC replaces the R91-100-, all control voltages

ESR61M-8..230V UC replaces partially the R81, all control voltages

R91-100-230V

R81-002-230V

R91-100-12VR91-100-230VR91-100-*

1 NO 10A1 NO 10A1 NO 10A

EAN 4010312 203101EAN 4010312 203125

22,00 €/pc.22,00 €/pc. 25,60 €/pc.

R81-001-12VR81-001-230VR81-001-*

R81-002-12VR81-002-230VR81-002-*

1 CO 10A1 CO 10A1 CO 10A

2 CO 10A2 CO 10A2 CO 10A

EAN 4010312 203064EAN 4010312 203088

EAN 4010312 203026EAN 4010312 203040

21,90 €/pc.21,90 €/pc.25,40 €/pc.

26,70 €/pc.26,70 €/pc.30,60 €/pc.

Page 105: Catalogo_Eltako_2009_ing

1-, 2- and 4- pole 25A electromechanical installation contactors XR12

K4

1- and 2-pole, 25A/250V ACModular devices for DIN 50022 rail mounting with manual control and switch position indicator. 1 module = 18mm wide, 55mm deep.

100% time on. Control power demand 1.9W.

Contacts 1 NO, 2 NO, 1 NO + 1 NC.Contact gap 3mm.

Contact /contact test voltage 2000V and control connection/contact test voltage 4000V.

Retrofi ttable auxiliary contact KM12, page J3.

XR12-100-/200-/110-

4-pole, 25A/250V ACModular devices for DIN 50022 rail mounting with manual control and switch position indicator. 2 modules = 36mm wide, 55mm deep.100% time on. Control power demand 4W.Contacts: 4 NO, 3 NO + 1 NC, 2 NO + 2 NC.Contact gap 3mm.Contact /contact test voltage 2000V and control connection/contact test voltage 4000V.Retrofi ttable auxiliary contact KM12, page J3.

XR12-400-/310-/220-

XR12-400-12VXR12-400-24VXR12-400-230VXR12-400-12V DCXR12-400-24V DCXR12-310-12VXR12-310-24VXR12-310-230VXR12-310-12V DCXR12-310-24V DCXR12-220-12VXR12-220-24VXR12-220-230VXR12-220-12V DCXR12-220-24V DC

4 NO 25A4 NO 25A4 NO 25A4 NO 25A4 NO 25A

3 NO + 1 NC 25A3 NO + 1 NC 25A3 NO + 1 NC 25A3 NO + 1 NC 25A3 NO + 1 NC 25A

2 NO + 2 NC 25A2 NO + 2 NC 25A2 NO + 2 NC 25A2 NO + 2 NC 25A2 NO + 2 NC 25A

EAN 4010312 201350EAN 4010312 201367EAN 4010312 201374EAN 4010312 202913EAN 4010312 201381

EAN 4010312 201404EAN 4010312 201411EAN 4010312 201428EAN 4010312 203217EAN 4010312 201435

EAN 4010312 201459EAN 4010312 201466EAN 4010312 201473EAN 4010312 202906EAN 4010312 201480

46,30 €/pc.46,30 €/pc.40,70 €/pc.46,30 €/pc.46,30 €/pc.46,30 €/pc.46,30 €/pc.40,70 €/pc.46,30 €/pc.46,30 €/pc.46,30 €/pc.46,30 €/pc.40,70 €/pc.46,30 €/pc.46,30 €/pc.

Recommended retail prices excluding VAT.

Technical data page K5.

XR12-400-230V

XR12-100-12VXR12-100-24VXR12-100-230VXR12-100-12V DCXR12-100-24V DCXR12-200-12VXR12-200-24VXR12-200-230VXR12-200-12V DCXR12-200-24V DCXR12-110-12VXR12-110-24VXR12-110-230VXR12-110-12V DCXR12-110-24V DC

1 NO 25A1 NO 25A1 NO 25A1 NO 25A1 NO 25A

2 NO 25A2 NO 25A2 NO 25A2 NO 25A2 NO 25A

1 NO + 1 NC 25A1 NO + 1 NC 25A1 NO + 1 NC 25A1 NO + 1 NC 25A1 NO + 1 NC 25A

EAN 4010312 201183EAN 4010312 201190EAN 4010312 201206EAN 4010312 203422EAN 4010312 201213

EAN 4010312 201282EAN 4010312 201299EAN 4010312 201305EAN 4010312 203446EAN 4010312 201312

EAN 4010312 201237EAN 4010312 201244EAN 4010312 201251EAN 4010312 203439EAN 4010312 201268

27,00 €/pc.27,00 €/pc.25,10 €/pc.27,00 €/pc.27,00 €/pc.32,20 €/pc.32,20 €/pc.29,60 €/pc.32,20 €/pc.32,20 €/pc.32,20 €/pc.32,20 €/pc.29,60 €/pc.32,20 €/pc.32,20 €/pc.

XR12-110-230V

Technical data page K5.

Page 106: Catalogo_Eltako_2009_ing

Technichal data electromechanical switching relays and installation contactors

ContactsXR12 R12 R81/R91

Contact material /contact gap AgSnO2/ 3mm 1) AgSnO2/ 3mm AgSnO2/ 2mm

Spacing of control connections/contact > 6 mm > 6 mm > 6 mm

Test voltage contact /contactTest voltage control connections/contact

2000 V4000 V

2000 V4000 V

2000 V4000 V

Rated switching capacity25A/250 V AC 16 A/400 V AC

16A/250 V AC10A/400 V AC

10 A/250 V AC6A/400 V AC

Fluorescent lamp load wih KVG*shunt-compensated or with EVG*

1000 VA 500 VA 500 VA

Compact fl uorescent lamps with EVG*and energy saving lamps ESL I on 140 A/10 ms 2) I on 140 A/10 ms 2) I on 70 A/10 ms 2)

HQL and HQI non compensated 500 W 500 W –

Max. switching current DC1: 12V/24V DC 12A 8A 8A

Life at rated load, cos = 1 orincandescent lamps 1000 W at 100/h

> 10 5 > 10 5 > 10 5

Life at rated load,cos = 0.6 at 100/h

> 4 x104 > 4 x104 > 4 x104

Max. operating cycles 103/h 103/h 103/h

Closing time 10-20 ms 10-20 ms 10-20 ms

Opening time 5-15ms 5-15ms 5-15ms

Switch position indication yes yes yes

Manual control yes yes yes

Terminal cross-section 12 mm2 12 mm2 6 mm2

Maximum conductor cross-section 6 mm2 6 mm2 2.5 mm2

Screw head slotted/Phillips, pozidriv slotted/Phillips, pozidriv slotted/Phillips, pozidriv

Shock-hazard protection (on the device) VDE 0106 part 100 VDE 0106 part 100 VDE 0106 part 100

Solenoid System

Time on 100% 3) 100% 3) 100% 3)

Max./min. temperature at mounting location +50°C/-5°C +50°C/-5°C +50°C/-5°C

Control voltage range 0.9 to 1.1 x rated voltage 0.9 to 1.1 x rated voltage 0.9 to 1.1 x rated voltage

Coil power loss AC+DC ±20%1- and 2-pole 1.9W4-pole 4W

1- and 2-pole 1.9W4-pole 4W

R81: 5W R91: 2.5W

Total power loss with continous excitation atrated voltage and rated contact load

1- pole 4W, 2-pole 6W4-pole 12W

1- pole 4W, 2-pole 6W4-pole 12W

1-pole 7W 2-pole 9W

Max. parallel capacitance (length) of control lead 0.06μF (approx. 200 m) 0.06μF (approx. 200 m) 0.06μF (approx. 200 m)

Max. voltage induced at the control inputs 0.2 x rated voltage 0.2 x rated voltage 0.2 x rated voltage

1) Contact spacing of NC contacts 1.2mm. 2) A 40-fold inrush current has to be calculated for electronic ballast devices. For steady loads of 1200W or 600W use the current-limiting relay SBR12 or

SBR61. Product group G, page G8. 3) Whenever several impulse switches are continuously energised make sure there is adequate ventilation as a function of the calculated power loss.

K5

Compliance with: EN 60 669

*EVG = electronic ballast units; KVG = conventional ballast units

Page 107: Catalogo_Eltako_2009_ing

The

wid

e va

riety

Switching on the future.

ON/OFF switches, momentary-contact switches, group switches and indicator lights

ON/OFF switches A12, AF12 and AK12 L0Momentary-contact switches T12, TK12, DT12 and ZT12 L1Group switches G12 and G2K12, indicator lights K12 and 2K12 L2

L

Page 108: Catalogo_Eltako_2009_ing

ON/OFF switches A12, AF12 and AK12

L0

ON/OFF switch, 1 NO contact 16A /250V AC.Modular device for DIN-EN 50 022 rail mounting. 1 module=18mm wide, 55mm deep.

Contact gap 3mm. Test voltage 4000V.

With red/green position indicator.

ON/OFF buttons are blue.

A12-100-16A

ON/OFF switch, 1 NO contact 16A/250V ACwith integrated indicator light 230V.Modular device for DIN-EN 50 022 rail mounting. 1 module=18mm wide, 55mm deep.Contact gap 3mm. Test voltage 4000V. With red/green position indicator. With integrated red LED behind semi-translucent white spherical cap (OFF button), operating voltage 230V. Internally connected to terminal 2 of the 16A NO contact. The ON button is blue.

AF12-100-230V

ON/OFF switches, with 1 or 2 CO contacts 16A /250V AC.Modular devices for DIN EN 50 022 rail mounting. 1 module=18 mm wide, 55mm deep.

Contact gap 3mm. Test voltage 4000V.

The changeover buttons are blue.

A12-001-/002-16A

ON/OFF switches with one indicator light and 1 or 2 CO contacts.Modular devices for DIN EN 50 022 rail mounting.1 module=18mm wide, 55mm deep.

Contact gap 3mm. Test voltage 4000V.

With one LED connected in fl oating mode, in the colours: blue, red, green, white and in theoperating voltage 110-230V AC, ± 10%.

The colour of the spherical cap is always the same as the LED.1) Fu = Colour of spherical cap base.

AK12-001/002-230V-Fu

A12-100-16A 1 NO 16A EAN 4010312 700815 12,40 €/pc.

AF12-100-230V 1 NO 16A EAN 4010312 700808 24,70 €/pc.

A12-001-16A

AK12-001-230V-Fu 1)

AK12-002-230V-Fu 1)

1 CO 16A2 CO 16A

31,10 €/pc.39,80 €/pc.

AK12-001-230V-green

A12-001-16AA12-002-16A

1 CO 16A2 CO 16A

EAN 4010312 700822EAN 4010312 700839

17,50 €/pc.24,90 €/pc.

Recommended retail prices excluding VAT.

Page 109: Catalogo_Eltako_2009_ing

Momentary-contact switches T12, TK12, DT12 and ZT12

L1

Momentary-contact switches 1 NO contact, 1 or 2 CO contacts 16A/250V AC.Modular devices for DIN-EN 50 022 rail mounting.1 module=18mm wide, 55mm deep.Contact gap 3mm. Test voltage 4000V.The button of the T12-100-16A and T12-001-16A is available in one of the following colours:blue, black, red, green or white, the rest are blue.1) Fu = Colour of spherical cap base.

T12-100-16A-Fu, T12-001-16A-Fu and T12-002-16A-blue

Momentary-contact switch with one indicator light, 1 or 2 CO contacts 16A/250V AC.Modular devices for DIN-EN 50 022 rail mounting.1 module=18mm wide, 55mm deep.Contact gap 3mm. Test voltage 4000V. With one LED connected in fl oating mode, in one of the colours: blue, red, green or white. Operating voltage ±10%. The colour of the button is always the same as the LED, the rest is blue.

TK12-001-230V-Fu, TK12-8..24V UC-Fu and TK12-002-230V-blue

Dual momentary-contact switch, 1 NO contact and 1 NC contact 16A/250V AC.Modular device for DIN-EN 50 022 rail mounting.1 module=18mm wide, 55mm deep.

Contact gap 1.2mm. Test voltage 2000V.

The bottom, green button operates an NO contact and the top, red button operates an NC contact.

DT12-110-green/red

Dual momentary-contact switches, 1+1 NO contact 16A/250V AC.Modular devices for DIN-EN 50 022 rail mounting.1 module=18mm wide, 55mm deep.Contact gap 1.2mm. Test voltage 2000V. The two blue momentary-contact switches operate a changeover contact with neutral position with identical potential. The ZT12 dual momentary-contact switch can be used in particular for manual central control of the shading system and roller blind control. Therefore, the blue momentary-contact switches are marked and .

DT12-200-16A-blue and ZT12-200-16A-blue

TK12-001-230V-Fu1)

TK12-001-8..24V UC-Fu1)

TK12-002-230V-blue

1 CO 16A1 CO 16A2 CO 16A

EAN 4010312 701010

23,50 €/pc.23,50 €/pc.26,00 €/pc.

T12-

100-

16A-

blue

TK12

-001

-230

V-bl

ueDT

12-1

10-g

reen

/red

DT12

-200

-16

A-bl

ue

DT12-110-green/red 1 NO + 1 NC 16A EAN 4010312 700884 21,10 €/pc.

T12-100-16A-blueT12-100-16A-blackT12-100-16A-redT12-100-16A-greenT12-100-16A-yellowT12-100-16A-whiteT12-001-16A-Fu1)

T12-002-16A-blue

1 NO 16A1 NO 16A1 NO 16A1 NO 16A1 NO 16A1 NO 16A1 CO 16A2 CO 16A

EAN 4010312 700846EAN 4010312 701089EAN 4010312 700969EAN 4010312 701263EAN 4010312 701270EAN 4010312 701287 EAN 4010312 700860

13,20 €/pc.13,20 €/pc.13,20 €/pc.13,20 €/pc.13,20 €/pc.13,20 €/pc.18,30 €/pc.26,10 €/pc.

DT12-200-16A-blueZT12-200-16A-blue

1 + 1 NO 16A1 + 1 NO 16A

EAN 4010312 700976EAN 4010312 700877

24,80 €/pc.24,80 €/pc.

Recommended retail prices excluding VAT.

Page 110: Catalogo_Eltako_2009_ing

Group switches G12 and G2K12 Indicator lights K12 and 2K12

L2

Group switch, 1+1 NO contacts 16A/250V AC.Modular device for DIN EN 50 022 rail mounting.1 module=18mm wide, 55mm deep.

Contact gap 1.2mm. Test voltage 2000V.

With three switch positions: manual -0-automatic. The buttons are blue.

G12-200-16A

Group switches with two indicator lights, 1 + 1 NO contact 16A /250V AC.Modular devices for DIN EN 50 022 rail mounting.1 module=18mm wide, 55mm deep.

Contact gap 1.2mm. Test voltage 2000V.

With three switch positions: Manual -0 -Automatic.

With two LEDs connected in fl oating mode, in one of the colours: blue, red, green, yellow, white. Operating voltage 110-230V AC, ± 10%. The colour of the button is always the same as the LED.1) Fu=Colour of bottom spherical cap base, Fo=Coulour of spherical cap top.

G2K12-200-230V-Fu/Fo

Indicator lightsModular devices for DIN EN 50 022 rail mounting.1 module=18mm wide, 55mm deep.

With one or two LEDs connected in a fl oating mode, in one of the colours: blue, red, green, yellow or white. Operating voltage 110-230V AC, ± 10%. The colour of the spherical cap is always the same as the LED.

The spherical cap of the K12 which is not illuminated is blue.1) Fu=Colour of spherical cap base, Fo=Colour of spherical cap top.

K12-230V-Fu and 2K12-230V-Fu/Fo

G12-200-16A 1 + 1 NO 16A EAN 4010312 700891 21,10 €/pc.

G2K12-200-230V-Fu/Fo1) 1 + 1 NO 16A 37,80 €/pc.

K12-230V-blueK12-230V-redK12-230V-greenK12-230V-yellowK12-230V-white2K12-230V-Fu/Fo1)

EAN 4010312 700914EAN 4010312 700921EAN 4010312 700938EAN 4010312 700945EAN 4010312 700952

20,40 €/pc.20,40 €/pc.20,40 €/pc.20,40 €/pc.20,40 €/pc.26,00 €/pc.

2K12-230V-yellow/green

Recommended retail prices excluding VAT.

Page 111: Catalogo_Eltako_2009_ing

Z1

For series 81,l x w x h = 60 x 60 x 37mm.

Surface cap K81

For series 91,l x w x h = 60 x 60 x 35mm.

Surface cap K9

For series 81, for mounting on DIN-EN 50 022 rail.

Clip-on plate P8

For series 91, for mounting on DIN-EN 50 022 rail.

Clip-on plate P9

1/2 module wide = 9mm, to produce and maintain a ventilation clearance for modular devices dissipating much heat, e.g. dimmers from 300W/400W and continuously rated electromechanical impulse switches.

Spacer DS12

The KM1 plastic mounting bracket that comes with the device is also available as an individual (accessory) item, e.g. for mounting the light sensor LS.

Plastic mounting bracket KM1

Surface cap K81 EAN 4010312 901236 4,70 €/pc.

Surface cap K9 EAN 4010312 900734 2,10 €/pc.

Clip-on plate P8 EAN 4010312 900703 1,00 €/pc.

Clip-on plate P9 EAN 4010312 900727 1,00 €/pc.

Spacer DS12 EAN 4010312 900987 1,00 €/pc.

Plastic mounting bracket KM1 EAN 4010312 901311 4,70 €/pc.

Recommended retail prices excluding VAT.

Accessories

Page 112: Catalogo_Eltako_2009_ing

Accessories

Z2

For single-phase energy meters WSZ12B with 2 modules = 35mm wide and three-phase energy meters without terminal cover clap DSZ12B with 4 modules = 70mm wide. Covers the terminals and can be sealed.

If necessary 1 or 2 sealing caps can be used, one above and one below.

Sealing cap PK36

Modular device for DIN-EN 50 022 rail mounting.1 module=18mm wide, 55mm deep.Used to compensate for inductive interference voltages on control leads. Up to three switchgear devices can be interference-suppressed by connection in parallel with the 230V control inputs.

Triple RC module RC12-230V

Modular device for DIN-EN 50 022 rail mounting.1 module=18mm wide, 55mm deep.

Housing without front panel to insert operating instructions.

Housing for operating instructions GBA12

Unverbindliche Preisempfehlung zuzüglich gesetzl. MwSt.Socket outlet 16A as modular device for mounting on DIN-EN 50022 rail or as built-in device.

2,5 modules = 45mm wide, 55mm deep.

Recommended retail prices excluding VAT.

For all sealable modular devices of series 12 with one module. Covers the back terminals as well as the latched sliding switch and can be sealed. If necessary two sealing caps can be used, one above and one below.

Sealing cap PK18

Sealing cap PK18 EAN 4010312 901403 1,00 €/pc.

Socket outlet ST12-16A

Sealing cap PK36 EAN 4010312 901670 1,00 €/pc.

RC12-230V EAN 4010312 201596 31,70 €/pc.

GBA12, Housing for operating BA EAN 4010312 901779 2,20 €/pc.

ST12-16A EAN 4010312 700358 15,50 €/pc.

Page 113: Catalogo_Eltako_2009_ing

V

Type table

For ELTAKO series 11 in comparison with the up-to-date series 12.

Devices of series 12, which have not existed in former series and which have still the same type name, are not listed here.

Electronic impulse switches

Series 11 Series 12 Changes Up-to-date Page

ES12-8..230V,8..24V, 230V, 12V

ES12-100- ES12DX-UC A1

ES11-100- ES12-100- ES12DX-UC A1

ES12-001- ES12-110- A3

ES11-110- ES12-110- ES12-110- A3

ES11-200- ES12-200- ES12-200- A2

ES12-2x- ES12M- ESR12M- A5

ES12-400- ES12-4x ESR12Z-4DX A7

ES12Z-4x ESR12Z-4DX- A7

ES12NP- ESR12NP- A4

ES11.2-001- ES12.2-001- ES12Z-110- A6

ES11.3- ES12Z- ES12Z-200- A6

ES11.4- ES12Z- ES12Z-200- A6

ES11.1- ES12.9- ESV12NP- ESR12NP- A4

ESV12- ESV12NP- ESR12NP- A4

ESV12.1- ESV12NP- ESR12NP- A4

ESV12.2P- ES12.1P- EUD12M- B3

ES12.1NP ES12Z-200- A6

ES12.1-8..230V ES12Z-200- A6

ES11.2-100- ES12.2-100- ES12Z-100- ES12Z-200- A6

ES11.2-110- ES12.2-110- ES12Z-110- A6

ES11.2-200- ES12.2-200- ES12Z-200- A6

ES12.3-001- ES12.1-110- ES12Z-110- A6

ES12.4-001- ES12.1-110- ES12Z-110- A6

ES12.5-001- ES12.1-110- ES12Z-110- A6

ES12.6-200- ES12.1-200- ES12Z-200- A6

ES12.7-200- ES12.1-200- ES12Z-200- A6

ES12.8-200- ES12.1-200- ES12Z-200- A6

ES12.1-500- ES12.1-4x- ESR12Z-4DX- A7

ES12.1-400- ES12.1-4x- ESR12Z-4DX- A7

ES12Z-4x ESR12Z-4DX- A7

EGS11.2/.3- EGS12-200- EGS12.1 EGS12Z H4

EGS11.2/.3- EGS12-200- EGS12.2 EGS12Z2 H5

ESD12- ESD12U- EUD12NP- B1

ESD11-HT- ESD12.2- ESD12.2U- EUD12Z- B2

ESD11-HT- ESD12.2- ESD12.2U- EUD12Z- B2

1000W +ELD12- +EUL12- +LUD12- B5

ESD12UF EUD12F B4

Mains monitoring relays and current relays

Series 11 Series 12 Changes Up-to-date Page

NR11-110- NR12-001- NR12-110- NR12-001- G2

NR12-002- NR12-002- G2

NR11.1-110- NR12-001- NR12-110- NR12-001- G2

NR12-002- NR12-002- G2

AR12-001-230V AR12NP-230V G1

Electronic switching relays, control relays and coupling relays

Series 11 Series 12 Changes Up-to-date Page

ER11-001- ER12-001- ER12-001- C5

ER12-100- ER12DX- C1

ER11-200- ER12-200- ER12-200- C2

ER11-002- ER12-002- ER12-002- C6

EKR11-001- EKR12-001- ER12-001- C5

ER12P- EUD12M- B3

ER12NP- ESR12NP- C3

ER12M- ESR12M- C4

Electromechanical impulse switches

Series 11 Series 12 Changes Up-to-date Page

S11-100- S12-100- S12-100- J2

S11-110- S12-110- S12-110- J2

S11-200- S12-200- S12-200- J2

SS11-110- SS12-110- SS12-110- J2

GS11-110- GS12-110- ESR12M- A3

S11-400- S12-400- S12-400- J3

S11-310- S12-310- S12-310- J3

S11-220- S12-220- S12-220- J3

S12.2-, XS12.2- ES12Z- A6

S12.3-, XS12.3- ES12Z- + ER12 A6+C1

Electromechanical switching relays

Series 11 Series 12 Changes Up-to-date Page

R11-100- R12-100- R12-100- K2

R11-110- R12-110- R12-110- K2

R11-200- R12-200- R12-200- K2

R11-020- R12-020-230V R12-020-230V K2

R11-400- R12-400- R12-400- K2

R11-310- R12-310- R12-310- K2

R11-220- R12-220- R12-220- K2

VR11- VR12- ER12- C2+C5

ESR12- C3

Staircase time switches, off-delay timers

Series 11 Series 12 Changes Up-to-date Page

TLZ12.0- TLZ12E- TLZ12NP- D1

TLZ12.0E- TLZ12E- TLZ12NP- D1

TLZ11-220V TLZ12- TLZ12NP- D1

EZ11-220V TLZ12- TLZ12NP- D1

TLZ12.2- TLZ12NP- D1

EZ11.1- TLZ12.1- TLZ12M- D2

TLZ12.3- TLZ12NP- D1

TLZ12.4- TLZ12M.1 TLZ12M- D2

TLZ12.9- TLZ12-9E- D4

TLZ12.4P- TLZ12P- EUD12M- B3

EZ11.7-220V NLZ12- NLZ12NP- D6

EZ11.7-8V NLZ12.1- NLZ12NP- D6

Page 114: Catalogo_Eltako_2009_ing

VI

Type table

For ELTAKO series 11 in comparison with the up-to-date series 12.

For ELTAKO series 8, 9 and 60 in comparsion with the up-to-date series 81, 91 and 61.

Control relays

Series 60 Series 61 Changes Up-to-date Page

ER60- ER61- ER61- C7

Impulse switches/Staircase time switches/Off-delay timers

Series 60 Series 61 Changes Up-to-date Page

ES60- ES61- ES61- A8

ES60.1- ES61.9- ESV61- ESR61NP- A8

ESD61- EUD61NP- B8+B9

EZ60/TLZ60- TLZ61- TLZ61NP-230V D5

TLZ61.1-.4-TLZ61NP-8..230V UC

D5

EZ60.2/NLZ60- NLZ61- NLZ61- D7

NLZ61.1- NLZ61NP- D7

Impulse switches /Switching relays

Series 9 Series 91 Changes Up-to-date Page

1S9- S91-100- S91-100- J4

1R9- R91-100- R91-100- K3

Series 8 Series 81 Changes Up-to-date Page

1S8- S81-001- S81-001- J4

2S8- S81-002- S81-002- J4

WS8- S81-002- S81-002- J4

SS8- SS81-002- SS81-002- J4

GS8- GS81-002- GS81-002- J4

1R8- R81-001- R81-001- K3

2R8- R81-002- R81-002- K3

WR8- R81-002- R81-002- K3

RR8- R81-002- R81-002- K3

Devices of series 12, which have not existed in former series and which have still the same type name, are not listed here.

* If controlled only by a LS and/or WS the USR12- can also be replaced by a LDW12-. The MSR12- needs a multi sensor MS12.

Mains disconnecting relays

Series 11 Series 12 Changes Up-to-date Page

FR11-100- FR12-100- FR12.1- FR12 G4FR12.0- FR12.1- FR12 G4

Time relays

Series 11 Series 12 Changes Up-to-date Page

MFZ11- MFZ12- MFZ12.1- MFZ12- E2

EZ11.2- EZ12.2- EZ12RV- E3

EZ11.3- EZ12.3- EZ12AV- E3

EZ11.4- EZ12.4- EZ12TI- E3

EZ11.5- EZ12.5- EZ12EW- EZ12EAW E3

EZ11.6- EZ12.6- EZ12AW- EZ12EAW- E3

EZ12.9- EZ12SRV- MFZ12- E2

EZ12ARV- MFZ12- E2

DMZ12 MFZ12DDX E1

DMZ12- DMZ12.1- MFZ12DDX E1

DZ12.2- DZ12RV- MFZ12DDX E1

DZ12.3- DZ12AV- MFZ12DDX E1

DZ12.4- DZ12TI- MFZ12DDX E1

DZ12.5- DZ12EW- MFZ12DDX E1

DZ12.6- DZ12AW- MFZ12DDX E1

DZ12.9- DZ12SRV- MFZ12DDX E1

TI12P- EUD12M- EUD12M- B3

Shading systems and roller shutter control

Series 11 Series 12 Changes Up-to-date Page

EGS11.2/.3- EGS12-200- EGS12.1- EGS12Z H4

EGS11.2/.3- EGS12-200- EGS12.2- EGS12Z2 H5

USR12-* MSR12- H2

LSR12- LDW12- H3

MTR12-400 MTR12- H5

Single-phase energy meters

Series 11 Series 12 Changes Up-to-date Page

WSZ12-20A WSZ12B-25A WSZ12B-32A F2

WSZ12B-20A WSZ12B-25A WSZ12B-32A F2

WSZ12-32A WSZ12B-32A WSZ12B-32A F2

WSZ12-65A WSZ12B-65A WSZ12B-65A F2

On/off switches, momentary contact switches, indicator lights

Series 11 Series 12 Changes Up-to-date Page

KS11-100- A12-100- A12-100- H1

KS11-200- A12-100- A12-100- H1

T11-100- T12-100- T12-100- H1

PK12-3- P3K12 G6