Page 1: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

®

Technical Catalogue

BANKABLE VALVES

January

2018

web edition

Page 2: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso
Page 3: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

IE/BANK-INDEX/01-2015 0

i1

2

3

4

5

6

Bankable valves

Table of contentsTECHNICAL INFORMATION ...............................................................................................................2

SIZE 6 ................................................................................................................................................5 ON/OFF AND PROPORTIONAL VALVES (CDC3 / CD3 / CX3 / CXQ3) .............................6 Composition form ....................................................................................................................8 Inlet module units ..................................................................................................................10 Working sections ...................................................................................................................25 Intermediate element ............................................................................................................47 Outlet module units ..............................................................................................................53

PRE AND POST COMPENSATED VALVES (CXDH3 / CDH3 / CFS3) .............................56 Composition form ..................................................................................................................58 Inlet module units ..................................................................................................................59 Working sections ...................................................................................................................65 Outlet module units ..............................................................................................................78

SIZE 10 ..............................................................................................................................................79 ON/OFF VALVES (CD5) ........................................................................................................80 Composition form ..................................................................................................................81 Inlet module units ..................................................................................................................82 Working sections ...................................................................................................................85 Outlet module units ..............................................................................................................88

MODULAR ELEMENTS ......................................................................................................................89 Valves and modular elements ..............................................................................................90

ACCESSORIES ....................................................................................................................................97 Interface for proportional directional valves HPV41 .............................................................98 Mounting kit ..........................................................................................................................99 Fixing feet ............................................................................................................................101 Calibrated diaphragms ........................................................................................................102 Connectors ...........................................................................................................................103 Coils. ....................................................................................................................................104

HOW TO ORDER ..............................................................................................................................111 Examples. .............................................................................................................................112

ELECTROMAGNETIC COMPATIBILITY .........................................................................................115

© 2018 Dana Brevini S.p.A. all rights reserved. Hydr-App, SAM Hydraulik, Aron, Brevini Hydraulics, BPE Electronics, VPS Brevini, OT Oiltechnology, logos are trademarks or are registered trademarks of Dana Brevini S.p.A. or other companies Dana in Italy and other countries.

The technical features supplied in this catalogue are non binding and no legal action can be taken against such material. Dana Brevini will not be held responsi-ble for information and specifications which may lead to error or incorrect interpretations. Given the continuous technical research aimed at improved technical features of our products, Dana Brevini reserves the right to make change that are considered appropriate without any prior notice. This catalogue cannot be reproduced (in while or in part) without the prior written consent of Dana Brevini. This catalogue supersedes all previous ones.

Use of the products in this catalogue must comply with the operating limits given in the technical specifications. The type of application and operating condi-tions must be assessed as normal or in malfunction in order to avoid endangering the safety of people and/or items.

®

1

Page 4: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

i

min. max.

ISO VG 10 10 9.00 11.0

ISO VG 15 15 13.5 16.5

ISO VG 22 22 19.8 24.2

ISO VG 32 32 28.8 35.2

ISO VG 46 46 41.4 50.6

ISO VG 68 68 61.2 74.8

ISO VG 100 100 90.0 110

15000

600

4000400

2000

5000

200

1000

1500

100

400

500

40

200

300

20

50

1505 30

50

SSU °E mm²/s

310

20000500

5000

10000 300 3000

2000

150

1500

1000

50

500

400

30

300

200

10

100

100

4

40

2

20

0 1 0

mm²/s°E

°C

°F

ISO

VG

100

ISO

VG

68

ISO

VG

32

ISO

VG

22

ISO

VG

46

-20

2.80

3

3.5

4

4.5

5

6

7

8

9

10

12

11

13

15

17

20

25

30

40

50

60

70

100

150

200

300

400

600

800

1000

1500

2000

3000

5000

7000

10000

2000

1000

500

300

200

100

70

40

20

10

8

6

4

3

2

1.8

1.6

1.4

1.3

1.2

-5-15 0-10 5 10 15 20 40 60 9025 30 50 8070 100

210140 200130100700

110

IE/BANK-INDEX/01-2015

TECHNICAL INFORMATION

Read this instructions carefully before installation. All operations must be carried out by qualified personnel following the instructions.

The user must periodically inspect, based on the conditions of use and the substances used, the presence of corrosion, dirt, the state of wear and correct function of the valves.

Always observe first the operating conditions given in datasheet of the valve.

INTRODUCTION

VISCOSITY

Observe the recommendations given in the data sheet of the valve.The oil viscosity must be in the range of 10 mm²/s to 500 mm²/s.Recommended oil viscosity 46 mm2/s (32 mm2/s for Cartridge valves)

Table 1: ISO viscosity grades

Kinematic-viscosity limits

mm²/s @ 40°C

Averagekinematicviscosity

mm²/s @ 40°C

Viscositygrade

= Values used in the chart “Oil viscosity according to temperature”

OIL VISCOSITY ACCORDING TO TEMPERATURE

CONVERSION TABLE SSU / °E / mm²/s

HYDRAULIC FLUID

Observe the recommendations given in the data sheet of the valve. Use only mineral oil (HL, HLP) according to DIN 51524. Use of other different fluids may damage the good operation of the valve.

®

2

Page 5: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

i

IE/BANK-INTRO/02-2015

CONTAMINATION

Oil contamination is the main cause of faults and malfunction in hydraulic systems. Abrasive particles in the fluid erode or block moving parts, leading to system malfunction.The valves we are offering do not require filtering characteristics any higher than those needed for usual hydraulic components such as pumps, motors, etc.

However, accurate filtering does guarantee reliability and a long life to all the system’s hydraulic parts. Reliable performance and long working life for all oil-pressure parts is assured by maintaining the level of fluid contamination within the limits specified in the data sheet of the valve.

Hydraulic fluid must also be cleaned properly before filling the hydraulic cir-cuit, especially when commissioning a new system, as this is when the oil contamination generally peaks due to its flushing effect on the components, and the running-in of the pump.Maximum contamination level is required on datasheet of the valve accord-ing to ISO 4406:1999.

In the following table there is the correspondence between ISO 4406:1999 and old standard NAS 1638 for information purpose:The standard ISO 4406:1999 defines the contamination level with three num-bers that relate with the number of particles of average dimension equal or greater than 4 μm, 6 μm e 14 μm, in 1 ml of fliuid.

In following table there is a reference to reccomended contamination level and correspondence with old NAS 1638 standard.

Type of systemType of valve

Oil filtration recommendationsCleanliness class

recommendedAbsolute filtration

micron rating ( ** )

ISO 4406 : 1999 NAS 1638 ( * )

Systems or components operating at HIGH PRESSURE > 250 bar (3600 psi)HIGH DUTY CYCLE APPLICATIONSSystems or components with LOW dirt tolerance

18 / 16 / 13 7 - 8 5

Systems or components operating at MEDIUM / HIGH PRESSURESystems and components with moderate dirt tolerance

19 / 17 / 14 9 10

Systems or components operating at LOW PRESSURE < 100 bar (1500 psi)LOW DUTY CYCLE APPLICATIONSSystems and components with GOOD dirt tolerance

20 / 18 / 15 10 - 11 20

* Contamination class NAS 1638: it is determined by counting the total particles of different size ranges contained in 100 ml of fluid.

** Absolute filtration: it is a characteristic of each filter, it refers the size (in micron) of the largest sperical particle wich may pass through the filter.

Table 2: Reccomanded contamination level.

Ambient temperature range: -25°C to +60°CFluid temperature range (NBR seals): -25°C to +75°CThermal shocks can affect the performance and the expected life of the prod-uct, hence it is necessary to protect the product from these conditions.

WORKING TEMPERATURES

SEALS

O-rings made in Acrylonitrile Butadiene (NBR) are normally fitted on the valves. The backup rings that protect the O-rings are also made in NBR, or sometimes PTFE. Both the O-rings and the backup rings are suitable for the working temperatures mentioned above.In the case of fluid temperatures > 75°C, FKM seals must be used (identified with “V1” variant).

Solenoid valves coils are designed to operate safely in the voltage range of ±10% of nominal voltage at max. 60°C ambient temperature. The combination of permanent overvoltage and very hot temperatures can stress the solenoid. Therefore always a good heat dissipation and voltage level has to be assured.Faulty coils may only be replaced by new, interchangeable, tested compo-nents in original-equipment quality.Before removing a coil, voltage must be disconnected.When replacing the coil, be aware to insert O-Rings in order to avoid the entrance of water.

ELECTRICAL POWER SUPPLY

TECHNICAL INFORMATION

The mounting surface must feature surface quality specified in data sheet of the valve: for example for Cetop valves generally is required Ra 1.6μm and flatness 0.03 mm over 100 mm length. Normally in cartridge valve for sea-ling diameters of the cavities, is required roughness Ra 1.6μm. The surfaces and openings in the assembly plate must be free from impurity or dirt.Make sure the O-Rings fit correctly in their seats.Fixing screws must comply with the dimensions and the strength class spe-cified in the data sheet and must be tightened at the specified tightening torque.Complete the electrical wiring. For circuit examples and pin assignments, see the relevant datasheet.

INSTALLATION

Observe the functional limits indicated in the technical catalogueOn a periodic basis and based on the conditions of use, check for cleanliness, state of wear or fractures and correct performance of the valve.If the O-rings are damaged, replace them with those supplied by the manu-facturer.To assure the best working conditions at all time, check the oiland replace it periodically (after the first 100 working hours and then after every 2000 working hours or at least once every year).Attention: all installation and maintenance intervention must be performed by qualified staff.

USE AND MAINTENANCE

TRANSPORT AND STORAGE

The valve must be handled with care to avoid damage caused by impact, which could compromise its efficiency.In the case of storage, keep the valves in a dry place and protect against dust and corrosive substances.When storing for periods of more than 6 months, fill the valve with preserving oils and seal it.

®

3

Page 6: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

i

IE/BANK-INTRO/02-2015

TECHNICAL INFORMATION

Type SI units Alternative units Conversion factor

Force Newton (N) [kgm/s²]Kilogram force (kgf) 1 kgf = 9.807 N

pound force (lbf) [lbf/s²] 1 lgf = 4.448 N

Length

millimeter (mm) [10 m] inch (in) 1 in = 25.4 mm

meter (km) [1000 m] yard (yd) [3ft] 1 m = 1.0936 yd

kilometer (km) [1000 m] mile (mile) [1760 yd] 1 mile = 1.609 km

Torque Newton meter (Nm) pound force.feet (lbf.ft) 1 lbf.ft = 1.356 Nm

Power kiloWatt (kW) [1000 Nm/s]horsepower (hp) 1 kW = 1.341 hp

metric horsepower (CV) 1 kW = 1.36 CV

Pressure MegaPascal (MPa) [ N/mm²]

bar 1 MPa = 10 bar

psi (lbf/ln²) 1 MPa = 145 psi

ton/f/ln² 1 ton/f/ln² = 15.45 MPa

Flow rate liter/min (l/min)UK gal/min 1 UK gal/min = 4.546 l/min

US gal/min 1 US gal/min = 3.785 l/min

Temperature Degrees Celsius (°C) Farenheit (°F) 1°F = 1.8 °C+32

CONVERSION CHART

®

4

Page 7: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

IE/BANK-ONOFF/02-2015

SIZE 6

ON/OFF VALVES

PROPORTIONAL VALVES

PRE AND POST

COMPENSATED VALVES

®

5

Page 8: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

IE/BANK-ONOFF/02-2015

69

C

D

10

7

32

46

Ch./H

ex.

10

T

FE

0231 F

U31

1009A 1009A

T

P

ON/OFF AND PROPORTIONAL VALVES

Overall dimensions with CDC3 valves

Introduction• Bankable ON/OFF directional control valves;• Bankable PROPORTIONAL directional control valves;• Bankable PROPORTIONAL COMPENSATED flow regulators;• ON/OFF valves available in two sizes, with reduced overall dimensions or

for high flow rates;

• Available for parallel or series circuits;• Available with housing with threaded ports or interfaces for modular valves;• Available for Load Sensing circuits;• Assemblable with FEH30 and FUH3 family inlet and outlet modules;• Assemblable with CXDH3, CDH3, CD5 family valves;• Assemblable with Dana Brevini HPV valves (intermediate element re-

quired).

No.elements

Inlet module

FE / FE02 FEC

mmD

mmC

mmD

mm2 192 180 202 190

3 238 226 248 236

4 284 272 294 282

5 330 318 340 326

6 376 364 386 374

7 422 410 432 420

8 468 456 478 466

®

6

Page 9: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

169

46

32

7

10

D

C

Ch./H

ex.

10 T

TFE

0231

FU

31

A A

B B

1009A 1009A

P

Overall dimensions with CD3 valves

No.elements

Inlet module

FE / FE02 FEC

mmD

mmC

mmD

mm2 192 180 202 190

3 238 226 248 236

4 284 272 294 282

5 330 318 340 326

6 376 364 386 374

7 422 410 432 420

8 468 456 478 466

ON/OFF AND PROPORTIONAL VALVES ®

7

Page 10: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

IE/BANK-ONOFF/02-2015

29

1

31

31

12

13

14

20

21

30

30

3

5

6

2

10

11

33

33

28

32

2726 25

18

17

16

15

23

22

24

19

4

8

9

7

Composition form

How to orderTo order the assembly, specify the codes in progressive order (inlet, valves, outlet, mounting kit, feet). See example page 112.

For any further special version not shown in this catalogue, please contact our Technical Department.

SIZE 6 valves CDC3, CD3, CX3 can be assembled with:- valves CXDH3, CDH3, CFS3 (page 56); - with SIZE 10 valves CD5 (page 80);- with proportional directional valves HPV41 (see catalogue code DOC00079) using the interface HSIF (page 98).

To obtain the best performances, we suggest to assemble the working sections with higher flow rate near the inlet module, leaving the ones with lower flow at the end of the assembled valve.

®

8

Page 11: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

IE/BANK-ONOFF/02-2015

Composition formRef. Type Description Page

1 FE3FELS

Inlet module units no pressure relief valve 10Inlet module units with LS line no pressure relief valve 11

2 FE02 Inlet module units with pressure relief valve (up to 20 l/min) 12

3 FE02Q Inlet module units with LS line, compensator and pressure relief valve 13

4 FE10FE10LS

Inlet module units with pressure relief valve 15Inlet module units with LS line with pressure relief valve 16

5 FE10S Inlet module units with side ports and pressure relief valve 17

6 FE10X Inlet module units with pressure relief valve for proportional pressure compensated flow regulator XQP3 19

7 XQP3 Pressure compensated flow regulator see catalogue “Valves and Electronics” code. DOC00078

8 FE10P Inlet module units with pressure relief valve and electrical venting valve 21

9 FE10PS Inlet module units with side ports, pressure relief valve and electrical venting valve 23

10 CDC3 Directional control bankable valve with A09 coils 25CDC3 / CDCM3 (variants) 34

11 CD3M3 Directional control bankable valve with pressure relief valve and A09 coils 30CDC3 / CDCM3 (variants) 34

12 CD3 Directional control bankable valve with D15 coils 35CD3 (variants) 40

13 CX3 Solenoid operating proportional control bankable valves 41

14 CXQ3 Open loop proportional pressure compensated bankable flow regulators 44

15 FI3A Intermediate element 47

16 FI3L Intermediate element with LS line 48

17 FI3RP Intermediate element with pressure reducing valve 49

18 CDC3R Directional control valve connection B-P for Intermediate element FI3BP 50

19 FI3BP Intermediate element for valve CDC3R 52

20 CD3 CDC3 CX3 Body G-H-M for modular valves 25 - 35 - 41

21 FU3 Outlet module units 53

22 FUT3 Outlet module units with side ports 54

23 FUS3 Outlet module units with overcenter and top port 55

24 V08000005 Intermediate element with flow regulator on A and B lines 90

25 V08000002 Intermediate element with pilot operated check stackable valves 91

26 CM3F Modular elements with ports A-B 92

27 CM3P Modular pilot operated check bankable valves 93

28 CM3M Modular max. pressure bankable valves 95

29 HSIF Interface for proportional directional valves HPV41 98

30 — Mounting kit 99

31 — Fixing feet 101

32 — Connectors 103

33 — Coils 104

®

9

Page 12: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FE3

FE

3

*

**

2

70

35

49

59

60

30

43

11 14

29 32

n. 4 fori

2 x OR 2-012 90Sh

6.5

P

T

IE/FE3002/01/2011

P

T

INLET MODULE UNITS NO PRESSURE RELIEF VALVE

HYDRAULIC SYMBOL

FEATURES

Max. operating pressure 250 barMax. Flow 40 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm²/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 0.3 kg

Module units FE no pressure relief valve. • Threaded ports (P and T), G3/8“ or 9/16”-18UNF• Maximum fl ow 40 l/min.• Aluminum body.

Inlet module unitno pressure relief valve

Size

Port sizes:1 = G3/8"2 = 9/16”-18UNF 00 = No variantV1 = Viton

Serial No.

ORDERING CODE OVERALL DIMENSIONS

®

10

Page 13: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FELS

FELS

3

1

**

2

IE/FELS002/02/2012

35

70

11

4370

49

59

14

32

N°4 Ø 6.5

G 1/4"

35

28

40

11

.52

91

4

OR 2037/2-012 90Sh

OR 2018/2-008 90Sh

P

T

LS

FELS31 2

P

T

LS

INLET MODULE UNITS WITH LS LINE NO PRESSURE RELIEF VALVE

HYDRAULIC SYMBOL

FEATURES

Max. operating pressure 250 barMax. Flow 40 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm²/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 0.3 kg

Module units FELS with LS line, no pressure relief valve. • Threaded ports (P and T) sizes G3/8” and LS size G1/4”. • Maximum fl ow 40 l/min.• Aluminum body.

Inlet module unit no pressure relief valve with LS line

Size

Ports:1 = G3/8” (P,T ports) G1/4” (LS port) 00 = No variantV1 = Viton

Serial No.

ORDERING CODE OVERALL DIMENSIONS

®

11

Page 14: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FE02

1 = 0÷50 bar - 2 = 35÷90 bar - 3 = 75÷190 bar - 4 = 160÷290 bar

FE02

3

*

C

*

**

3

IE/FE023003/02-2015

70

7.531.5

60 43

11

30

14

28.5

49 n. 4 fori

2 x OR 2-012 90Sh

6.5

CH 3

CH 10CH 24

P

T

59

49.3 max

4

3

2

1

Q (l/min)

P(b

ar)

0 2 4 6 8 10 12 14 16 18 200

5

10

15

20

25

30

35

40

45

55

50

1

2

3

4

Q (l/min)

P(b

ar)

00 2 4 6 8 10 12 14 16 18 20

50

100

150

200

250

300

350

P

T

INLET MODULE UNITS WITH PRESSURE RELIEF VALVE (UP TO 20 L/MIN)

HYDRAULIC SYMBOL

PRESSURE-FLOW RATE MIN.SETTING PRESSURE

Fluid used: mineral based oil with viscosity 46 mm²/s at 40°C.

FEATURES

Max. operating pressure 250 barMax. Flow 20 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 0.42 kg

(*) The minimum permissible setting pressure depending on the spring: see curves.

Module units FE02 with CMP-MC/MS adjustable pressure relief valve• Manual adjustment with a grub screw. • Fhreaded ports (P and T) sizes G3/8” or 9/16””-18UNF.• Maximum fl ow 20 l/min. • Aluminum body.

ORDERING CODE

Inlet module unit (up to 20 l/min)with pressure relief valve

Size

Port sizes:1 = G3/8"2 = 9/16”-18UNF Adjustment:C = Grub screw

Setting ranges1 = 0 ÷ 50 bar (white spring)2 = 35 ÷ 90 bar (green spring)3 = 75 ÷ 190 bar (yellow spring)4 = 160 ÷ 290 bar ** (red spring) 00 = No variantV1 = Viton

Serial No.

OVERALL DIMENSIONS

Pressure relief valve (CMP-MC/MSSetting range (*):Spring 1Spring 2Spring 3Spring 4

max 50 barmax 90 barmax 190 barmax 290 bar

(**) Setting referred to the maximum pressure reached from the relief valve. Do not exceed the maximum working pressure 250 bar.

®

12

Page 15: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FE02Q

IE/FE02Q001/02-2016

FE02Q

3

*

C

*

**

1

0

2

12

4

14

6

16

8

10

0 2 4 6 8 10 12 14 16 18 20

Q (l/min)

P(b

ar)

P

T T

P

Ls

P1 GRY GRX

Ø0.6

Grano cieco

Plug

INLET MODULE UNITS WITH LS LINE, COMPENSATOR AND PRESSURE RELIEF VALVE

HYDRAULIC SYMBOL

ORDERING CODE

Max. operating pressure 250 barMax. Flow 40 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 1 kg

(*) The minimum permissible setting pressure depending on the spring: see curves.

Pressure relief valve (CMP-MC/MSSetting range (*):Spring 1Spring 2Spring 3Spring 4

max 50 barmax 90 barmax 190 barmax 290 bar

FEATURES

Module units FE02Q with pressure compensator for fi xed displacement pumps and CMP-MC/MS adjustable pressure relief valve on LS line • Manual adjustment with a grub screw. • Screw with orifi ce for LS bleeding.• Threaded ports P-T, G3/8” and LS, G1/4”.• Maximum fl ow 40 l/min. • Aluminum body.

Inlet module unit (up to 40 l/min)with compensator and pressure relief valve

Size

Ports:1 = G3/8” (P,T ports) - G1/4” (LS port)2 = 9/16”-18UNF (P,T ports) - 7/16”-20UNF (LS port) Adjustment:C = Grub screw

Setting ranges1 = 0 ÷ 50 bar (white spring)2 = 35 ÷ 90 bar (green spring)3 = 75 ÷ 190 bar (yellow spring)4 = 160 ÷ 290 bar ** (red spring) 00 = No variantV1 = Viton

Serial No.

(**) Setting referred to the maximum pressure reached from the relief valve. Do not exceed the maximum working pressure 250 bar.

Fluid used: mineral based oil with viscosity 46 mm²/s at 40°C.

PRESSURE COMPENSATOR

To obtain a correct compensation the inlet fl ow must be 8% greater the sum of the regulated fl ow.

®

13

Page 16: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FE02Q

OR 2037/2-012 90Sh

OR 2018/2-008 90Sh

18

51,80 85

16

48

59

G 3/8"

G 3/8"

49

16

11

53

66

59

49

57

70

N°4 Ø 6.5

IE/FE02Q001/01-2015

OVERALL DIMENSIONS

®

14

Page 17: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

1 = max 50 - bar - 2 = max 150 bar - 3 = max 320 bar

FE10

3

*

*

*

**

2

FE10

IE/FE103002/01/2011

1

2

3

0 5 10 15 20 25 30 35 40

0

40

80

120

160

200

240

280

320

360

Q (l/min)

P(b

ar)

3

2

1

0 5 10 15 20 25 30 35 40

0

20

40

60

80

100

Q (l/min)

P(b

ar)

C

M

70

49

59

52.5 max

11.526.5

60 43

11

40

14

29

n. 4 fori Ø 6.5

2 x OR 2-012 90Sh

CH 5

P

T

54 max

P

T

INLET MODULE UNITS WITH PRESSURE RELIEF VALVE

HYDRAULIC SYMBOL

PRESSURE-FLOW RATE

Fluid used: mineral based oil with viscosity 46 mm²/s at 40°C.

FEATURES

Max. operating pressure 250 barMax. Flow 40 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 0.6 kg

(*) The minimum permissible setting pressure depending on the spring: see curves.

Module units FE10 with CMP10 adjustable pressure relief valve.• Manual adjustment with a grub screw or plastic knob. • Threaded ports P-T sizes G3/8” or 9/16”-18UNF.• Maximum fl ow 40 l/min. • Aluminum body.

ORDERING CODE

Inlet module unit (up to 40 l/min)with pressure relief valve

Size

Port sizes:1 = G3/8”2 = 9/16”-18UNF Adjustment:M = Plastic knobC = Grub screw

Setting ranges1 = max. 50 bar (white spring)2 = max. 150 bar (yellow spring)3 = max. 320 bar** (green spring) 00 = No variantV1 = Viton

Serial No.

OVERALL DIMENSIONS

MIN.SETTING PRESSURE

C = Grub screwM = Plastic knob

Pressure relief valve (CMP10...)Setting range (*):Spring 1Spring 2Spring 3

max 50 barmax 150 barmax 320 bar

(**) Setting referred to the maximum pressure reached from the relief valve. Do not exceed the maximum working pressure 250 bar.

®

15

Page 18: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FE10LS

3

1

*

*

**

2

1 = max 50 bar - 2 = max 150 bar - 3 = max 320 bar

IE/FE10LS3002/03-2015

FE10LS

1

2

3

0 5 10 15 20 25 30 35 40

0

40

80

120

160

200

240

280

320

360

Q (l/min)

P(b

ar)

3

2

1

0 5 10 15 20 25 30 35 40

0

20

40

60

80

100

Q (l/min)

P(b

ar)

49

59

11

14

43

29

70

70

26.5 11.5

54 max

10.5

5.5

N°4 Ø 6.5

C

P

T

LS

FE10LS31 2

20

28

40

62.5 max

M

14

29

11

.5

352 x OR 2037/2-012 90Sh

OR 2018/2-008 90Sh

FE10LS.. FE10LS..J6.

P

T

LS

P

T

LS

INLET MODULE UNITS WITH LS LINE WITH PRESSURE RELIEF VALVE

HYDRAULIC SYMBOL

PRESSURE-FLOW RATE MIN.SETTING PRESSURE

Fluid used: mineral based oil with viscosity 46 mm²/s at 40°C.

FEATURES

Max. operating pressure 250 barMax. Flow 40 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 0.6 kg

(*) The minimum permissible setting pressure depending on the spring: see curves.

Module units FE10LS with LS line and CMP10 adjustable pressure relief valve.• Manual adjustment with a grub screw or plastic knob. • Threaded ports P-T, G3/8” and LS, G1/4”.• Maximum fl ow 40 l/min. • Aluminum body.

ORDERING CODE

Inlet module unit (up to 40 l/min)with pressure relief valve and LS line

Size Ports:1 = G3/8” (P,T ports) G1/4” (LS port) Adjustment:M = Plastic knobC = Grub screw Setting ranges1 = max. 50 bar (white spring)2 = max. 150 bar (yellow spring)3 = max. 320 bar ** (green spring) 00 = No variantJ6 = With LS bleedV1 = Viton Serial No.

OVERALL DIMENSIONS

C = Grub screwM = Plastic knob

Pressure relief valve (CMP10...)Setting range (*):Spring 1Spring 2Spring 3

max 50 barmax 150 barmax 320 bar

(**) Setting referred to the maximum pressure reached from the relief valve. Do not exceed the maximum working pressure 250 bar.

®

16

Page 19: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FE10S

3

*

*

*

**

1

1 = max 50 bar - 2 = max 150 bar - 3 = max 320 bar

IE/FE10S001/01-2015

FE10S

1

2

3

0 5 10 15 20 25 30 35 40

0

40

80

120

160

200

240

280

320

360

Q (l/min)

P(b

ar)

3

2

1

0 5 10 15 20 25 30 35 40

0

20

40

60

80

100

Q (l/min)

P(b

ar)

P

M

T

HYDRAULIC SYMBOL

PRESSURE-FLOW RATE MIN.SETTING PRESSURE

Fluid used: mineral based oil with viscosity 46 mm²/s at 40°C.

FEATURES

Max. operating pressure 250 barMax. Flow 40 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 0.6 kg

Inlet module units FE10S with side ports and CMP10 adjustable pressure re-lief valve. • Manual adjustment with a grub screw or plastic knob. • Threaded ports P-T, G3/8” or G3/8”(P) - G1/2”(T). • Maximum fl ow 40 l/min. • Aluminum body.

ORDERING CODE

Inlet module unit with side ports and pressure relief valve (up to 40 l/min)

Size

Ports:1 = G3/8” ports P,T 5 = G3/8” port P - G1/2” port T Adjustment:M = Plastic knobC = Grub screw

Setting ranges1 = max. 50 bar (white spring)2 = max. 150 bar (yellow spring)3 = max. 320 bar ** (green spring) 00 = No variantV1 = Viton

Serial No.

Pressure relief valve (CMP10...)Setting range (*):Spring 1Spring 2Spring 3

max 50 barmax 150 barmax 320 bar

(**) Setting referred to the maximum pressure reached from the relief valve. Do not exceed the maximum working pressure 250 bar.

INLET MODULE UNITS WITH SIDE PORTS AND PRESSURE RELIEF VALVE

(*) The minimum permissible setting pressure depending on the spring: see curves.

®

17

Page 20: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FE10S

IE/FE10S001/01-2015

59

49

43

80

G 1/4"

54 m

ax

90

35

G 1/8"

P

T

C M

62.5

max

2 x O-RING 2-012 90Sh

OVERALL DIMENSIONS

C = Grub screwM = Plastic knob

®

18

Page 21: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FE10X

3

*

*

*

**

1

1 = max 50 bar - 2 = max 150 bar - 3 = max 320 bar

IE/FE10X001/01-2015

FE10X

1

2

3

0 5 10 15 20 25 30 35 40

0

40

80

120

160

200

240

280

320

360

Q (l/min)

P(b

ar)

3

2

1

0 5 10 15 20 25 30 35 40

0

20

40

60

80

100

Q (l/min)

P(b

ar)

P P

T T

XQP3

FE10X

HYDRAULIC SYMBOL

PRESSURE-FLOW RATE MIN.SETTING PRESSURE

Fluid used: mineral based oil with viscosity 46 mm²/s at 40°C.

FEATURES

Max. operating pressure 250 barMax. Flow 40 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 19/17/14NAS 1638: class 8

Weight 0.6 kg

Module units FE10X for proportional pressure compensated fl ow regulator XQP3 . With CMP10 adjustable pressure relief valve. • Manual adjustment with a grub screw or plastic knob. • Threaded ports P-T sizes G3/8”.• Maximum fl ow 40 l/min. • Aluminum body.

ORDERING CODE

Inlet module unit (up to 40 l/min)for proportional pressure compensated fl ow regulator

Size

Ports:1 = G3/8” ports P,T

Adjustment:M = Plastic knobC = Grub screw

Setting ranges1 = max. 50 bar (white spring)2 = max. 150 bar (yellow spring)3 = max. 320 bar ** (green spring) 00 = No variantV1 = Viton

Serial No.

Pressure relief valve (CMP10...)Setting range (*):Spring 1Spring 2Spring 3

max 50 barmax 150 barmax 320 bar

(**) Setting referred to the maximum pressure reached from the relief valve. Do not exceed the maximum working pressure 250 bar.

INLET MODULE UNITS WITH PRESSURE RELIEF VALVE FOR PROPORTIONAL PRESSURE COMPENSATED FLOW REGULATOR XQP3

(*) The minimum permissible setting pressure depending on the spring: see curves.

®

19

Page 22: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FE10X

IE/FE10X001/01-2015

24

39

70

14

41

58 max49

59

29

58

31.5

59

82.5

C

P

T

M

62.5 max

29

33,5

40,5

32,5

31

N°4 M5

ISO 4401 CETOP3/NG6

2 x O-RING 2-012 90Sh

OVERALL DIMENSIONS

C = Grub screwM = Plastic knob

XQP3 To order, see catalogue

“Valves and Electronics” code. P35030200

®

20

Page 23: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FE10P

FE10

P

3

*

*

**

2

IE/ FE10P3002/01/2011

*

*

P

M

T

INLET MODULE UNITS WITH PRESSURE RELIEF VALVE AND ELECTRICAL VENTING VALVE

HYDRAULIC SYMBOL

FEATURES

(*) The minimum permissible setting pressure depending on the spring: see curves.

Module units FE10P with CMP10 adjustable pressure relief valve and electri-cal venting valve CRP0418NA normally open supplied with emergency con-trol.• Manual adjustment with a grub screw or plastic knob. • Threaded ports P-T sizes G3/8” or 9/16”-18UNF.• Pressure gauge M, G1/4”• Maximum fl ow 40 l/min.• Aluminum body.

ORDERING CODE

Inlet module unitwith pressure relief valve

Electric venting valve

Size

Port sizes:1 = G3/8”2 = 9/16”-18UNF Adjustment:M = Plastic knobC = Grub screw

Setting ranges1 = max. 50 bar (white spring)2 = max. 150 bar (yellow spring)3 = max. 320 bar** (green spring)

Voltage for the electricventing valve (Tab. 1) S1 = No variantsSV = VitonPY = Push button emergency (see page 22)PS = Rotary emergency (see page 22)AJ = AMP Junior connection (see page 104)CX = Deutsch connection with bidirectional diode (see page 104)

Serial No.

Max. operating pressure 250 barMax. Flow 40 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 1.1 kg

Pressure relief valve (CMP10...)Setting range (*):Spring 1Spring 2Spring 3

max 50 barmax 150 barmax 320 bar

Electrical venting valve (CRP04..NA..)Max. excitation frequency 2 HzDuty cycle 100% EDType of protection (in relation to the connector usad) IP65

Tab.1 - Voltage - Coil 18W/22W (1)

Connector to be ordered separately, see page 103.

L 12 VDCM 24 VDCN 48 VDC2 21.6 VDCZ (2) 102 VDC RACX (3) 205 VDC RAC

W (4) Without coil

(1) Connector to be ordered separately, see page 103; Coils technical data, see page 104; (2) With rectifi er: 115 VAC/50Hz - 120 VAC/60Hz(3) With rectifi er: 230 VAC/50Hz - 240 VAC/60Hz(4) Performance are guaranteed only using valves completed with coil

(**) Setting referred to the maximum pressure reached from the relief valve. Do not exceed the maximum working pressure 250 bar.

®

21

Page 24: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1 1 = max 50 bar 2 = max 150 bar 3 = max 320 bar

IE/FE10P3002/01/2011

FE10P

1

2

3

0 5 10 15 20 25 30 35 40

0

40

80

120

160

200

240

280

320

360

Q (l/min)

P(b

ar)

3

2

1

0 5 10 15 20 25 30 35 40

0

20

40

60

80

100

Q (l/min)

P(b

ar)

Q (l/min)

P(b

ar)

0

2

4

6

8

10

12

14

16

0 10 20 30 40

Q (l/min)

P(b

ar)

0

50

100

150

200

250

300

0 10 20 30 40

3,5 Corsa

(Stroke)

Ø1

0

38 max

19

Ø2

0

Ø1

0

29,538.5

60.8

47.8

23.5

39

20

.5

40

.561

.5

C = Grub screwM = Plastic knob

DIAGRAMS - PRESSURE RELIEF VALVE

DIAGRAMS - ELECTRICAL VENTING VALVE

OVERALL DIMENSIONS

PRESSURE DROPS LIMITS OF USE

PRESSURE-FLOW RATE MIN.SETTING PRESSURE

STANDARD EMERGENCY

Fluid used: mineral based oil with viscosity 46 mm²/s at 40°C.

Fluid used: mineral based oil with viscosity 46 mm²/s at 40°C.

VARIANTS

“PS” Emergency rotary

“PY” Emergency with push button

“AJ” AMP Junior

“CX” Deutsch with diode

®

22

Page 25: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FE10PS

FE10

PS

3

*

*

**

2

IE/ FE10PS3002/02-2016

*

*

P

M

T

INLET MODULE UNITS WITH SIDE PORTS, PRESSURE RELIEF VALVE AND ELECTRICAL VENTING VALVE

HYDRAULIC SYMBOL

FEATURES

(*) The minimum permissible setting pressure depending on the spring: see curves.

Inlet module units FE10PS with side ports, CMP10 adjustable pressure relief valve and electrical venting valve CRP0418NA normally open supplied with emergency control.• Manual adjustment with a grub screw or plastic knob. • Threaded ports P-T sizes G3/8” • Pressure gauge M, G1/4”• Maximum fl ow 40 l/min.• Aluminum body.

ORDERING CODE

Inlet module unitwith pressure relief valve

Electric venting valve and side ports

Size

Port sizes:1 = G3/8”

Adjustment:M = Plastic knobC = Grub screw

Setting ranges1 = max. 50 bar (white spring)2 = max. 150 bar (yellow spring)3 = max. 320 bar** (green spring)

Voltage for the electricventing valve (Tab. 1) S1 = No variantsSV = VitonPY = Push button emergency (see page 22)PS = Rotary emergency (see page 22)AJ = AMP Junior connection (see page 104)CX = Deutsch connection with bidirectional diode (see page 104)

Serial No.

Max. operating pressure 250 barMax. Flow 40 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 1.1 kg

Pressure relief valve (CMP10...)Setting range (*):Spring 1Spring 2Spring 3

max 50 barmax 150 barmax 320 bar

Electrical venting valve (CRP04..NA..)Max. excitation frequency 2 HzDuty cycle 100% EDType of protection (in relation to the connector usad) IP65

Tab.1 - Voltage - Coil 18W/22W (1)

Connector to be ordered separately, see page 103.

L 12 VDCM 24 VDCN 48 VDC2 21.6 VDCZ (2) 102 VDC RACX (3) 205 VDC RAC

W (4) Without coil

(1) Connector to be ordered separately, see page 103; Coils technical data, see page 104; (2) With rectifi er: 115 VAC/50Hz - 120 VAC/60Hz(3) With rectifi er: 230 VAC/50Hz - 240 VAC/60Hz(4) Performance are guaranteed only using valves completed with coil

(**) Setting referred to the maximum pressure reached from the relief valve. Do not exceed the maximum working pressure 250 bar.

®

23

Page 26: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1 1 = max 50 bar 2 = max 150 bar 3 = max 320 bar

IE/FE10PS3002/02-2016

FE10PS

1

2

3

0 5 10 15 20 25 30 35 40

0

40

80

120

160

200

240

280

320

360

Q (l/min)

P(b

ar)

3

2

1

0 5 10 15 20 25 30 35 40

0

20

40

60

80

100

Q (l/min)

P(b

ar)

Q (l/min)

P(b

ar)

0

2

4

6

8

10

12

14

16

0 10 20 30 40

Q (l/min)

P(b

ar)

0

50

100

150

200

250

300

0 10 20 30 40

3,5 Corsa

(Stroke)

Ø1

0

38 max

19

Ø2

0

Ø1

0

29,538.5

60.8

47.8

23.5

39

20

.5

40

.561

.5

C = Grub screwM = Plastic knob

DIAGRAMS - PRESSURE RELIEF VALVE

DIAGRAMS - ELECTRICAL VENTING VALVE

OVERALL DIMENSIONS

PRESSURE DROPS LIMITS OF USE

PRESSURE-FLOW RATE MIN.SETTING PRESSURE

STANDARD EMERGENCY

Fluid used: mineral based oil with viscosity 46 mm²/s at 40°C.

Fluid used: mineral based oil with viscosity 46 mm²/s at 40°C.

VARIANTS

“PS” Emergency rotary

“PY” Emergency with push button

“AJ” AMP Junior

“CX” Deutsch with diode

®

24

Page 27: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

CDC3

IE/CDC3002/02-2017

CDC

3

*

**

**

2

*

*

E

DIRECTIONAL CONTROL BANKABLE VALVE WITH A09 COILS

Directional control bankable valve CDC3 with single or double solenoid.• Centring achieved by means of calibrated length springs which immedi-

ately reposition the spool in the neutral position when the electrical signal is shut off.

• Different springs used for each spool to improve the valve performance.• Emergency control.• Body for parallel or series connections• Threaded ports sizes G3/8” or 9/16”-18UNF (SAE 6), with or without LS

line.• Coils protection IP65 • Power supply DC or AC (with rectifier).• Standard connectors DIN 43650 ISO 4400, AMP Junior, flying leads and

Deutsch• Maximum flow until 30 l/min.• Cast iron zinc plated body.

Connector to be ordered separately, see page 103.

FEATURES

Max. pressure ports P/A/B/T 250 barMax. Flow 30 l/minMax excitation frequency 3 HzDuty cycle 100% EDHydraulic fluid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (filter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight with one DC solenoidWeight with two DC solenoids

1.25 kg1.50 kg

ORDERING CODE

Directional control bankable valve (with A09 coil)

Size

Body type (tab. 1)

Electrical operator

Spool (tab.2)

Mounting (tab.3)

Voltage (tab.4)

Variants (tab.5)

Serial No.

Calibrated diaphragms on P line, see page 102.

®

25

Page 28: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

CDC3

IE/CDC3002/02-2017

ORDERING CODE

Two solenoids,spring centred “C” Mounting

Code Covering Transient position

01 +

02 -

03 +

04 (2) -

One solenoid, side A “E” Mounting

Code Covering Transient position

01 +

02 -

03 +

04 (2) -

15 -

16 +

One solenoid, side B “F” Mounting

Code Covering Transient position

01 +

02 -

03 +

04 (2) -

15 -

16 +

Code Variant

S1 No variant

SV Viton

LF (11) Emergency control lever (see page 34)

LR Emergency control lever 180° rotated (see page 34)

ES Emergency button (see page 34)

P2 (9) Rotary emergency button (see page 34)

R5 (9) Rotary emergency b. 180° (see page 34)

3T First elem. for series connec.

AJ (10) AMP Junior connection (see page 105)

FL (10) Coil with flying leads 250 mm (see page 105)

LD (10) Coil with flying leads 130 mm and integrated diode (see page 105)

CX (10) Deutsch connecection with bidirectional diode (see page 105)

(1) For series connection configuration, a special individual bankable valve CDC3*E04**3T2 (A B or G parallel body type only, with spool 04 type, 3T variant) must always be used as first element. For other individual bankable valve must use body D E or H connector series type with spool 04 only.

(2) Specials with price increasing(3) Special voltage(4) Require connector with rectifier: 115 VAC/50Hz - 120 VAC/60Hz(5) Require connector with rectifier: 230 VAC/50Hz - 240 VAC/60Hz(6) Performance are guaranteed only using valves completed with coil(7) Connector to be ordered separately, see page 103; Coils technical data, see page 105; Voltage codes are not stamped on the plate, their are readable on the coils(8) Other variants available on request(9) Tightening torque max. 6÷9 Nm (CH n. 22)(10) Available in 12V or 24V DC voltage only(11) For the body type G - H - M order LR variant (Emergency control lever180°

rotated)

Code BodyA Ports G3/8” parallelB Ports 9/16” - 18UNF parallelD (1) Ports G3/8” seriesE (1) Ports 9/16” - 18UNF series

G Attachment styleParallel presetting for modular valves

H (1)Attachment styleSeries presetting for modular valves

I Ports 9/16” - 18UNF parallel - LS vers. L Ports G3/8” parallel - LS vers.

M Attachment style, parallel-LS vers. Presetting for modular valves

S Special connection B-P-A (see outlet module unit FUS3 pag .55)

U Ports G3/8” parallel - P-T closed (not require the outlet module units)

Tab.1 - Body type

Tab.2 - Standard spools

Tab.3 - Mounting

Tab.5 - Variants (7-8)

Tab.4 - Coils A09 voltage (7)

Code Voltage Max. winding temperature(Ambient temperature 25°C)

Rated powerW

Resistance @ 20°C (Ohm) ±7%

L 12 Vdc 123 °C 27 5.3

M 24 Vdc 123 °C 27 21.3

N (3) 48 Vdc 123 °C 27 85.3

Z (4) 102 Vdc 123 °C 27 392

P (3) 110 Vdc 123 °C 27 448

X (5) 205 Vdc 123 °C 27 1577

W (6) Without coils

Code Symbol

C

E

F

G (2)

H (2)

®

26

Page 29: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

TT

P

T VMP

P

T

A A

A A

B B

A A

B B

T

O O

P

T

A

A

O

B

A B B B

B

A A

A A

B B

A A

B B

T

O O

P

BA

B

O

A

A B B B

CDC3 A ... CDC3 B ... CDC3 D ... CDC3 E ... CDC3 G ... CDC3 H ...

CDC3 I ... CDC3 L ...

CDC3 M ...

CDC3

IE/CDC3002/02-2017

CDC3 S ... CDC3 U ...

BA

T

P

AA

B

O

B

T

BA

P

BA

AB

O

T

BA TT

P

BA

AB

O

P T

T TA B

BA

AB

O

A B

T

LSP

BA

AB

O

T

LSP LS

TBAT

BA

AB

O

T

A

B

P

A B

BA

AB

O

T

P

A B

BA

AB

O

HYDRAULIC SYMBOLS AND INSTRUCTION OF CONNECTION

PARALLEL CONNECTION SERIES CONNECTION

Special elementCDC3*E04**3T2

For series connection configuration, a special individual valve bank section (CDC3*E04**3T2) must always be used as first element (see ordering code page 25).

Special closing plug

HYDRAULIC SYMBOLS

®

27

Page 30: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

1

2

3

4

5

6

7

8

9

10

0 5 10 15 20 25 30

0

2

4

6

8

10

12

P(b

ar)

Q (l/min)

0 10 20 305 15 25

1

2

3

4

0

50

100

150

200

250

P(b

ar)

Q (l/min)

CDC3

IE/CDC3002/02-2017

PRESSURE DROPS - DIRECTIONAL CONTROL BANKABLE VALVE

LIMITS OF USE (MOUNTING C-E-F)

The diagram at the side shows the pressure drop curves for spools during normal usage.The fluid used is a mineral oil with a viscosity of 46 mm²/s at 40 C°; the tests have been carried out at a fluid temperature of 40 C°.

(p) Parallel connections(s) Series connections(E) Mounting E(F) Mounting F

The tests have been carried out with solenoids at operating temperature and a voltage 10% less than rated voltage with a fluid temperature of 50 C°. The fluid used was a mineral oil with a viscosity of 46 mm²/s at 40 degrees C. The values in the diagram refer to tests carried out with the oil flow in two direc-tions simultaneously (e.g. from P to A and at the same time B to T).

(4) = 15 and 16 spools used as 2 or 3 way, follow the curve No. 4

Spool type

ConnectionsP A P B A T B T P T P/T passing

01 4 4 4 4 — 902 (p) 7 7 6 6 7 902 (s) 7 7 6 6 8 —03 4 4 6 6 — 904 (p) 2 2 1 1 5 904 (s) 2 2 1 1 3 —15-16 (E) 6 6 10 10 — 915-16 (F) 6 6 5 5 — 9

Curve No.

Spool type Curve No.

01 102 103 304 2

15-16 1 (4)

In the cases where valves 4/2 and 4/3 are used with the flow in one direction only, the limits of use could have variations which may even be negative (See curve No 4 and Spool No 16 used as 2 or 3 ways). The tests were carried out with a counter-pressure of 2 bar at T port.

NOTE: The limits of use are valid for the C, E, F mounting.

®

28

Page 31: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

CDC3

IE/CDC3002/02-2017

= =

=

==

=

=

140

49

69.5

178.5

19 16

25

54.5

13

24

86

59

N° 4 Ø 6.5

2 x O-Ring 2-012 90Sh

=

129.5

178.5

69.5

49N°4 6.5∅

59

16

13

24

19

25

55

81.5

= =

= =

==

==

P

A B

10

09

A

T

2 x O-Ring 2-012 90Sh

46

==

LS

O-Ring 2-008 90Sh

24,5

T

A B

16

13

10.510.5

OVERALL DIMENSIONS

Only for LS versions

Single solenoid versions

Fittings, max. tightening torque 60 Nm

Manual emergency

Parallel body

Parallel bodyPresetting for modular

valves

Body "S" connection B-P-A

®

29

Page 32: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

CDCM3

IE/CDCM3003/01-2015

CDCM

3

*

**

*

*

*

*

E

CDCM3 N ..CDCM3 O .. CDCM3 P ..

**

3

BA

T

P

BA

AB

O

BA

T

P

BA

AB

O

P

T

A B

BA

AB

O

DIRECTIONAL CONTROL BANKABLE VALVE WITH PRESSURE RELIEF VALVE AND A09 COILS

Directional control bankable valve CDCM3 with single or double solenoid and one or two pressure relief valves with adjustable setting on A and/or B.• Centring achieved by means of calibrated length springs which immedi-

ately reposition the spool in the neutral position when the electrical signal is shut off.

• Different springs used for each spool to improve the valve performance.• Emergency control.• Body for parallel or series connections• Threaded ports sizes G3/8”• Coils protection IP65 • Power supply DC or AC (with rectifi er).• Standard connectors DIN 43650 ISO 4400, AMP Junior, fl ying leads and

Deutsch• Maximum fl ow until 30 l/min.• Cast iron zinc plated body.

Connector to be ordered separately, see page 103.

FEATURES

Max. pressure ports P/A/B/T 250 barMax. fl ow 30 l/minMax. fl ow - Pressure relief valve see diagrams page 32Max excitation frequency 3 HzDuty cycle 100% EDHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight with one DC solenoidWeight with two DC solenoids

1.40 kg1.65 kg

HYDRAULIC SYMBOLS

ORDERING CODE

Directional control bankable valve with relief valve (A09 coil)

Size

Body type (tab. 1)

Electrical operator

Spool (tab.2)

Mounting (tab.3)

Voltage (tab.4)

Pressure relief valve setting on A (tab. 5)

Pressure relief valve setting on B (tab. 5, omitted if equal to A)

Variants (tab.6)

Serial No.

Calibrated diaphragms on P line, see page 102.

®

30

Page 33: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

CDCM3

IE/CDCM3003/01-2015

ORDERING CODE

Two solenoids,spring centred “C” Mounting

Code Covering Transient position

01 +

02 -

03 +

04 (1) -

One solenoid, side A “E” Mounting

Code Covering Transient position

01 +

02 -

03 +

04 (1) -

15 -

16 +

One solenoid, side B “F” Mounting

Code Covering Transient position

01 +

02 -

03 +

04 (1) -

15 -

16 +

Code Variant

S1 No variant

LF Emergency control lever (see page 34)

ES Emergency button (see page 34)

P2 (9) Rotary emergency button (see page 34)

R5 (9) Rotary emergency b. 180° (see page 34)

AJ (10) AMP Junior connection (see page 105)

FL (10) Coil with flying leads 250 mm (see page 105)

LD (10) Coil with flying leads 130 mm and integrated diode (see page 105)

CX (10) Deutsch connecection with bidirectional diode (see page 105)

(1) Specials with price increasing(2) Special voltage(3) Require connector with rectifier: 115 VAC/50Hz - 120 VAC/60Hz(4) Require connector with rectifier: 230 VAC/50Hz - 240 VAC/60Hz(5) Performance are guaranteed only using valves completed with coil(6) Connector to be ordered separately, see page 103; Coils technical data, see page 105; Voltage codes are not stamped on the plate, their are readable on the coils(7) Other settings available on request(8) Other variants available on request(9) Tightening torque max. 6÷9 Nm (CH n. 22)(10) Available in 12V or 24V DC voltage only

Tab.1 - Body type

Tab.2 - Standard spools

Tab.3 - Mounting

Tab.6 - Variants (6-8)

Tab.4 - Coils A09 voltage (6)

Code Voltage Max. winding temperature(Ambient temperature 25°C)

Rated powerW

Resistance @ 20°C (Ohm) ±7%

L 12 Vdc 123 °C 27 5.3

M 24 Vdc 123 °C 27 21.3

N (2) 48 Vdc 123 °C 27 85.3

Z (3) 102 Vdc 123 °C 27 392

P (2) 110 Vdc 123 °C 27 448

X (4) 205 Vdc 123 °C 27 1577

W (5) Without coils

Code Symbol

C

E

F

G (1)

H (1)

Code BodyO Ports G3/8” parallel with relief valve on AP Ports G3/8” parallel with relief valve on BN Ports G3/8” parallel with relief valve on A and B

Tab.5 - Pressure relief valve settings (7)

Code Setting

0 1 ÷ 30 bar

1 31 ÷ 100 bar

2 101 ÷ 250 bar

®

31

Page 34: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

1

2

3

4

5

6

7

8

9

0 5 10 15 20 25 30

0

2

4

6

8

10

12

P(b

ar)

Q (l/min)

0 10 20 305 15 25

1

2

3

4

0

50

100

150

200

250

P(b

ar)

Q (l/min)

CDCM3

IE/CDCM3003/01-2015

1 = 1 ÷ 30 barbar 2 = 31 ÷ 100 bar 3 = 101 ÷ 250 bar

A B

T

P

A AB B

T

TT

P

Q (l/min)

P(b

ar)

3

2

1

0 1 2 3 4 5 6

0

50

100

150

200

250

300

Q (l/min)

P(b

ar)

1

2

3

0 1 2 3 4 5 6

0

20

40

60

80

100

120

140

160

HYDRAULIC SYMBOLS AND INSTRUCTION OF CONNECTION

PARALLEL CONNECTION

PRESSURE DROPS - DIRECTIONAL CONTROL BANKABLE VALVE

LIMITS OF USE (MOUNTING C-E-F)

The diagram at the side shows the pressure drop curves for spools du-ring normal usage.The fluid used is a mineral oil with a viscosity of 46 mm²/s at 40 C°; the tests have been carried out at a fluid temperature of 40 C°.

(p) Parallel connections(s) Series connections(E) Mounting E(F) Mounting F

The tests have been carried out with solenoids at operating temperature and a voltage 10% less than rated voltage with a fluid temperature of 50 C°. The fluid used was a mineral oil with a viscosity of 46 mm²/s at 40 degrees C. The values in the diagram refer to tests carried out with the oil flow in two direc-tions simultaneously (e.g. from P to A and at the same time B to T).

In the cases where valves 4/2 and 4/3 are used with the flow in one direction only, the limits of use could have variations which may even be negative (See curve No 4 and Spool No 16 used as 2 or 3 ways). The tests were carried out with a counter-pressure of 2 bar at T port.

NOTE: The limits of use are valid for the C, E, F mounting.

Spool type

ConnectionsP A P B A T B T P T P/T passing

01 3 3 3 3 — 802 (p) 6 6 5 5 6 803 3 3 5 5 — 804 (p) 2 2 1 1 4 815-16 (E) 5 5 9 9 — 815-16 (F) 5 5 4 4 — 8

Curve No.

Spool type

Curve No.

01 102 103 304 2

15-16 1 (4)

MAX PRESSURE SETTING MIN.SETTING PRESSURE

Fluid used: mineral based oil with viscosity 46 mm²/s at 40°C.

DIAGRAMS - PRESSURE RELIEF VALVES

(4) = 15 and 16 spools used as 2 or 3 way, follow the curve No. 4

®

32

Page 35: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

CDCM3

IE/CDCM3003/01-2015

2 x O-Ring 2-012 90Sh

16

13

19

24

25

30

59

49

26

81

N°4 Ø 6,5

= =

==

129,5

69,554,5 54,5

178,5

46

36

= =

==

==

==

OVERALL DIMENSIONS

Fittings, max. tightening torque 60 Nm

Manual emergency

Single solenoid versions

®

33

Page 36: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

IE/ CDC3-CDCM3-VAR/02-2016

39

59

18

46

66

.4

45

39

18

56

18

46

39

182

12

8

26,5

177

231,5

73

28°28°

19

1

“LF” AND “LR” VARIANTS - EMERGENCY CONTROL LEVER

HYDRAULIC SYMBOL

LF variant

LR variant

Emergency P2 and P5, tightening torque max. 6÷9 Nm (CH n. 22)

Thanks to his fl exibility, the component is designed to be inserted between the valve body and the spool, provid-ing total interchangeability between the different types of solenoid body valves manufactured by Dana Brevini.The control can be used as an emergency device in the event of power cuts.

“ES” Manual emergency

“P2”Rotary emergency

“R5” Rotary emergency 180°

“AJ” AMP Junior

“CX” Deutsch with diode

“FL” Flying leads“LD” Flying leads/diode

OTHER VARIANTS

CDC3 / CDCM3 (variants)

Max operating pressure port T

dynamic 160 barstatic 210 bar

Max operating pressure port Pfor series connection confi guration 160 bar

Mounting type C - F - H

Spools type 01 - 0204 - 16

Weight with single solenoid CDC3 2.21 kgCDCM3 2.36 kg

Weight with double solenoidCDC3 2.46 kgCDCM3 2.61 kg

®

34

Page 37: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

CD3

IE/CD3002/03-2017

CD

3

*

**

**

2

*

*

E

DIRECTIONAL CONTROL BANKABLE VALVE WITH D15 COILS

Directional control bankable valve CD3 with single or double solenoid.• Centring achieved by means of calibrated length springs which immedi-

ately reposition the spool in the neutral position when the electrical signal is shut off.

• Different springs used for each spool to improve the valve performance.• Emergency control.• Body for parallel or series connections• Threaded ports sizes G3/8” or 9/16”-18UNF (SAE 6), with or without LS

line.• Coils protection IP66 • Power supply DC or AC (with rectifi er).• Standard connectors DIN 43650 ISO 4400, AMP Junior, fl ying leads and

Deutsch• Maximum fl ow until 40 l/min.• Cast iron zinc plated body.

FEATURES

Max. pressure ports P/A/B/T 310 barMax. pressure port T 250 barMax. Flow 40 l/minMax excitation frequency 3 HzDuty cycle 100% EDHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight with one DC solenoidWeight with two DC solenoids

1.389 kg1.778 kg

ORDERING CODE

Directional control bankable valve (with D15 coil)

Size

Body type (tab. 1)

Electrical operator

Spool (tab.2)

Mounting (tab.3)

Voltage (tab.4)

Variants (tab.5)

Serial No.

Connector to be ordered separately, see page 103.

Calibrated diaphragms on P line, see page 102.

®

35

Page 38: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

CD3

IE/CD3002/03-2017

ORDERING CODE

Two solenoids,spring centred “C” Mounting

Code Covering Transient position

01 +

02 -

03 +

04 (2) -

One solenoid, side A “E” Mounting

Code Covering Transient position

01 +

02 -

03 +

04 (2) -

15 -

16 +

Code Symbol

C

E

F

G (2)

H (2)

One solenoid, side B “F” Mounting

Code Covering Transient position

01 +

02 -

03 +

04 (2) -

15 -

16 +

Code Variant

S1 No variant

SV Viton

LF (12) Emergency control lever (see page 40)

LR Emergency control lever180° rotated (see page 40)

ES Emergency button (see page 40)

P2 (9) Rotary emergency button (see page 40)

R5 (9) Rotary emergency b. 180° (see page 40)

3T First elem. for series connec.

AJ (10) AMP Junior connection (see page 106)

AD (10) AMP Junior and integr diode (see page 106)

SL (10) Coil with flying leads 175 mm (see page 106)

CZ (10) Deutsch DT04-2P connection (see page 107)

CX (10) Deutsch DT04-2P connection and integr diode (see page 107)

R6 (10) Deutsch DT04-2P connection eCoat surface treatment (see page 107)

RS (11) Hirschmann coil eCoat surface treatment (see page 107)

(1) For series connection configuration, a special individual bankable valve CD3*E04**3T2 (A B or G parallel body type only, with spool 04 type, 3T variant) must always be used as first element. For other individual bankable valve must use body D E or H connector series type with spool 04 only

(2) Specials with price increasing(3) Special voltage(4) Require connector with rectifier: 115 VAC/50Hz - 120 VAC/60Hz(5) Require connector with rectifier: 230 VAC/50Hz - 240 VAC/60Hz(6) Performance are guaranteed only using valves completed with coil(7) Connector to be ordered separately, see page 103; Coils technical data, see page 106 - 107; Voltage codes are not stamped on the plate, their are readable on the coils(8) Other variants available on request(9) Tightening torque max. 6÷9 Nm (CH n. 22)(10) Available in 12V or 24V DC voltage only.(11) Available in 12V, 24V, 28V or 110V DC voltage only(12) For the body type G - H - M order LR variant (Emergency control lever180°

rotated)

Tab.1 - Body type

Tab.2 - Standard spools

Tab.3 - Mounting

Tab.5 - Variants (7-8)

Tab.4 - Coils D15 voltage (7)

Code Voltage Max. winding temperature(Ambient temperature 25°C)

Rated powerW

Resistance @ 20°C (Ohm) ±10%

L 12 Vdc 110 °C 30 4.8

M 24 Vdc 110 °C 30 18.8

V (3) 28 Vdc 110 °C 30 25.6

N (3) 48 Vdc 110 °C 30 75.2

Z (4) 102 Vdc 110 °C 30 340

P (3) 110 Vdc 110 °C 30 387

X (5) 205 Vdc 110 °C 30 1375

W (6) Without coils

Code BodyA Ports G3/8” parallelB Ports 9/16” - 18UNF parallelD (1) Ports G3/8” seriesE (1) Ports 9/16” - 18UNF series

G Attachment styleParallel presetting for modular valves

H (1)Attachment styleSeries presetting for modular valves

I Ports 9/16” - 18UNF parallel - LS vers. L Ports G3/8” parallel - LS vers.

M Attachment style, parallel-LS vers. Presetting for modular valves

S Special connection B-P-A (see outlet module unit FUS3 pag .55)

U Ports G3/8” parallel - P-T closed(not require the outlet module units)

®

36

Page 39: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

CD3

IE/CD3002/03-2017

TT

P

T VMP

P

T

A A

A A

B B

A A

B B

T

O O

P

T

A

A

O

B

A B B B

B

A A

A A

B B

A A

B B

T

O O

P

BA

B

O

A

A B B B

CD3 A ... CD3 B ... CD3 D ... CDC3 E ... CD3 G ... CD3 H ...

CD3 I ... CD3 L ...

CD3 M ... CDC3 S ... CDC3 U ...

BA

T

P

A

AB

O

B

T

BA

P

BA

AB

O

T

BA TT

P

BA

AB

O

P T

T TA B

BA

AB

O

A B

T

LSP

BA

AB

O

T

LSP LS

TBAT

BA

AB

O

T

A

B

P

A B

BA

AB

O

T

P

A B

BA

AB

O

HYDRAULIC SYMBOLS AND INSTRUCTION OF CONNECTION

PARALLEL CONNECTION SERIES CONNECTION

Special elementCD3*E04**3T2

Special closing plug

For series connection configuration, a special individual valve bank section (CD3*E04**3T2) must always be used as first element (see ordering code page 35).

HYDRAULIC SYMBOLS

®

37

Page 40: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

CD3

IE/CD3002/03-2017 1

0 10 20 30 40

1

2

3

0

50

100

150

200

250

300

350

P(b

ar)

Q (l/min)

7

6

5

4

3

2

1

10 9 8

0 105 2015 3025 4035

0

2

4

6

8

10

12

14

16

18

20

P(b

ar)

Q (l/min)

PRESSURE DROPS - DIRECTIONAL CONTROL BANKABLE VALVE

LIMITS OF USE (MOUNTING C-E-F)

The diagram at the side shows the pressure drop curves for spools during normal usage.The fluid used is a mineral oil with a viscosity of 46 mm²/s at 40 C°; the tests have been carried out at a fluid temperature of 40 C°.

(p) Parallel connections(s) Series connections(E) Mounting E(F) Mounting F

The tests have been carried out with solenoids at operating temperature and a voltage 10% less than rated voltage with a fluid temperature of 50 C°. The fluid used was a mineral oil with a viscosity of 46 mm²/s at 40 degrees C. The values in the diagram refer to tests carried out with the oil flow in two direc-tions simultaneously (e.g. from P to A and at the same time B to T).

(3) = 16 spools used as 2 or 3 way, follow the curve No. 3

Spool type

ConnectionsP A P B A T B T P T P/T passing

01 6 6 6 6 — 102 (p) 5 5 4 4 2 102 (s) 5 5 5 5 3 —03 6 6 5 5 — 104 (p) 9 10 8 8 4 104 (s) 9 9 8 8 5 —15-16 (E) 5 7 5 9 — 115-16 (F) 7 5 9 5 — 1

Curve No.

Spool type Curve No.

01 102 103 104 215 316 1

In the cases where valves 4/2 and 4/3 are used with the flow in one direction only, the limits of use could have variations which may even be negative (See curve No 3 and Spool No 16 used as 2 or 3 ways). The tests were carried out with a counter-pressure of 2 bar at T port.

NOTE: The limits of use are valid for the C, E, F mounting.

®

38

Page 41: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

CD3

IE/CD3002/03-2017

=

==

=

49

59

80 8069.5

229.5

25 1

9 16

13

24

143

N° 4 Ø6,5

2 x O-Ring 2-012 90Sh

==

==

24.5

49

59

69.5

13

16

19

25

24

56

229.5

8080

=

=

=

=

= =

P

T T

A B

A B

1009A

N°4 Ø6.5

2 x O-Ring 2-012 90Sh

LS

O-Ring 2-008 90Sh

= =

155

30.5

Ø45

46

= =

==

16

13

10.510.5

OVERALL DIMENSIONS

Only for LS versions

Single solenoid versions

Fittings, max. tightening torque 60 Nm

Manual emergency

Parallel bodyPresetting for modular

valves

Parallel bodyBody "S"

connection B-P-A

®

39

Page 42: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

IE/CD3-VAR/02-2016

81

.5

22

.5

98.5

Ø 3

2

81

.5

22

.5

max 66

120

81

.5

17

Ø 3

0

22

.5

max 63

117

54.3

53.766.7

66.5

54.3

191

208

13

2

26,5

202,5

282,5

77

28°28°

65.7

54,3

53.7

54.3

“LF” AND “LR” VARIANTS - EMERGENCY CONTROL LEVER

OTHER VARIANTS

HYDRAULIC SYMBOL

LF variant

LR variant

Emergency P2 and P5, tightening torque max. 6÷9 Nm (CH n. 22)

“ES” Manual emergency

“P2”Rotary emergency

“AJ” AMP Junior“AD” AMP Junior + Diode

“CZ” Deutsch DT04-2P“R6” Deutsch DT04-2P eCoat treatment

“SL” Flying leads

“R5” Rotary emergency 180°

“RS” eCoat treatment

CD3 (variants)

Max operating pressure port T

dynamic 160 barstatic 210 bar

Max operating pressure port Pfor series connection confi guration 160 bar

Mounting type C - F - H

Spools type 01 - 02 - 0304 - 16

Weight with single solenoid Weight with double solenoid

2.35 kg2.74 kg

Thanks to his fl exibility, the component is designed to be inserted between the valve body and the spool, provid-ing total interchangeability between the different types of solenoid body valves manufactured by Dana Brevini.The control can be used as an emergency device in the event of power cuts.

®

40

Page 43: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

CX3

IE/CX3002/03-2016

CX

3

N

**

*

2

*

*

*

**

CX3 A ... CX3 C ... CX3 CL ...

T

P

OA

A B BA

AB

O

P

T

BA

AB

O

P

LS

T

SOLENOID OPERATING PROPORTIONAL CONTROL BANKABLE VALVES

Proportional control bankable valves CX3 with single or double solenoid.• Emergency control.• Body for parallel connections• Threaded ports sizes G3/8” or 9/16”-18UNF (SAE 6), with or without LS line.• Coils protection IP66 • Standard connectors DIN 43650 ISO 4400, AMP Junior, fl ying leads and

Deutsch• Regulated fl ow rate 3 / 10 / 15 / 20 l/min• Cast iron zinc plated body.

FEATURES

ORDERING CODE

Operating specifi cations are valid for fl uid with 46 mm²/s viscosity at 40°C, using the specifi ed Dana Brevini electronic control units.

Accessories

Max. operating pressure ports P/A/B 310 barMax. operating pressure ports T(Pressure dynamic allowed for 2 millions of cycles) 250 bar

Nominal fl ow with Dp 5 bar from P to A,B 3 / 10 / 15 / 20 l/minRelative duty cycle Continuous 100% EDType of protection (Hirschmann coil) IP 66Fluid viscosity 10 ÷ 500 mm²/sFluid temperature -20°C ÷ 75° CAmbient temperature -20°C ÷ 60°CMax. contamination level (fi lter ß10 75)

ISO 4406:1999: class 19/17/14NAS 1638: class 8

Weight with single solenoid (CX3A..)Weight with double solenoid (CX3C..)

1.389 kg1.778 kg

Solenoid @ 9Vdc @ 12Vdc @ 24VdcCurrent supply PWM (pulse width modulation)Max. current solenoid 2.35 A 1.76 A 0.88 ASolenoid coil resistance at 25°C (77°F) 2.25 Ohm 4.0 Ohm 16.0 OhmPWM or superimposed dither frequency 100 ÷ 150 Hz

REMSRA..REMDRA.. Card type control for single and double solenoid

CEPS... Electronic amplifi er plug version for signle solenoid

MAV Electronic module for integrate control of proportional valves and ON/OFF

JMPEI0M700101 Joystick with standard handleJMPIU0M700138 Joystick Person present handle

Proportional control bankable valve

Size

A = Single solenoidC = Double solenoid

Body type:A = Ports G3/8” parallelB = Ports 9/16” - 18UNF parallel G = Presetting for modular valves (parallel)L = Ports G3/8” parallel (LS version)

Type of spool

03 =

Symmetrical fl ow path control(see symbols table)

Nominal fl ow with Dp 5 bar from P to A,B1 = 3 l/min2 = 10 l/min3 = 15 l/min4 = 20 l/min

Max. current at solenoid (1):E = 2.35 A - Special coil (9 VDC)F = 1.76 A (12 VDC)G = 0.88 A (24 VDC)

Variants (1-2):S1 = No variantSV = VitonES = Emergency button (3)P2 = Rotary emergency (3) R5 = Rotary emergency 180° (3) AJ = Coil with AMP Junior connection (1)CZ = Coil with Deutsch connection DT04-2P (1)

Serial No.

HYDRAULIC SYMBOLS

Connector to be ordered separately, see page 103.

(1) Coils technical data, see page 109. Voltage codes are not stamped on the plate, their are readable on the coils(2) Connector to be ordered separately, see page 103;(3) Emergency (see page 42)

®

41

Page 44: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

CX3

IE/CX3002/03-2016

TT

P

Q (

l/m

in)

I (%)

0

5

10

15

20

25

0 10010 20 30 40 50 60 70 80 90

Q (l/min)

P(b

ar)

0 5 10 15 20 25 30

0

50

100

150

200

250

81

.5

22

.5

98.5

Ø 3

2

81

.5

22

.5

max 66

120

81

.5

17

Ø 3

0

22

.5

max 63

117

B BBA

T

P

T

A AA A A

B B B

HYDRAULIC SYMBOLS AND INSTRUCTION OF CONNECTION

PARALLEL CONNECTION

The fluid used is a mineral based oil with a viscosity of 46 mm²/s at 40°C. The tests have been carried out at with a fluid of a 40°C.

DIAGRAMS

INPUT SIGNALCX3.01N4...

POWER LIMITS TRANSMITTEDCX3.01N4...

VARIANTS

Emergency P2 and P5, tightening torque max. 6÷9 Nm (CH n. 22)

“ES” Manual emergency

“P2”Rotary emergency

“R5” Rotary emergency 180°

®

42

Page 45: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

CX3

IE/CX3002/03-2016

=

==

=

49

59

80 8069.5

229.5

25 1

9 16

13

24

143

N° 4 Ø6,5

2 x O-Ring 2-012 90Sh

==

==

24.5

49

59

69.5

13

16

19

25

24

56

229.5

8080

=

=

=

=

= =

P

T

A B

1009A

N°4 Ø6.5

2 x O-Ring 2-012 90Sh

LS

O-Ring 2-008 90Sh

= =

155

30.5

Ø45

46

= =

==

OVERALL DIMENSIONS

Parallel bodyPresetting for modular

valves

Parallel body Only for LS versions

Single solenoid versions

Fittings, max. tightening torque 60 Nm

Manual emergency

®

43

Page 46: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

CXQ3

IE/CXQ3002/02-2016

CXQ

3

D

*

2

*

C

*

**

CXQ3CT..

CXQ3CP..

(1) Dati tecnici bobine, vedi pag. 103 . Le tensioni non sono stampigliate sulle targhette, ma indicate sulla bobina (2) Connettori da ordinare separatamente, vedi pag. 97;(3) Emergenze, vedi pag. 46 T T

PIN POUT

E

T T

PIN POUT

OPEN LOOP PROPORTIONAL PRESSURE COMPENSATED BANKABLE FLOW REGULATORS

Open loop proportional fl ow regulator 3 way compensated with priority function.• Regulate the fl ow in proportion to an applied electrical current (REM, MAV

or CEPS power amplifi er). • Flow regulation is independent both from load – POUT port – and pump

fl ow variations. Load compensation is achieved by a spool compensator, which holds the pressure drop constant across the proportional spool.

• Emergency control.• Coils protection IP66 • Standard connectors DIN 43650 ISO 4400, AMP Junior, and Deutsch• Regulated fl ow rate 15 / 20 l/min• Cast iron zinc plated body.

FEATURES

ORDERING CODE

Operating specifi cations are valid for fl uid with 46 mm²/s viscosity at 40°C, using the specifi ed Dana Brevini electronic control units.

Accessories

Max. operating pressure ports Pin / Pout / E 250 bar

Max. operating pressure ports T(Pressure dynamic allowed for 2 millions of cycles) 250 bar

Regulated fl ow rate 15 / 25 l/minDecompression drain fl ow max 0.7 l/minRelative duty cycle Continuous 100% EDType of protection (Hirschmann coil) IP 66

Flow rate gain See diagram “Input signal fl ow”

Fluid viscosity 10 ÷ 500 mm²/sFluid temperature -20°C ÷ 75° CAmbient temperature -20°C ÷ 60°CMax. contamination level (fi lter ß10 75)

ISO 4406:1999: class 19/17/14NAS 1638: class 8

Weight version CXQ3CP..Weight version CXQ3CT..

2.25 kg1.75 kg

Solenoid @ 9Vdc @ 12Vdc @ 24VdcCurrent supply PWM (pulse width modulation)Max. current solenoid 2.35 A 1.76 A 0.88 ASolenoid coil resistance at 25°C (77°F) 2.25 Ohm 4.0 Ohm 16.0 OhmPWM or superimposed dither frequency 100 ÷ 150 Hz

REMSRA.. Card type control for single solenoidCEPS... Electronic amplifi er plug version for signle solenoid

MAV Electronic module for integrate control of proportional valves and ON/OFF

JMPEI0M700101 Joystick with standard handleJMPIU0M700138 Joystick Person present handle

Open loop 3 way proportional compensatedfl ow regulator for module units and bankable valves

Size

3 way compensation

P = 3 way (external excedence Line/ priority function)T = 3 way (internal excedence to T)

Nominal fl ow ratesH = 15 l/minI = 25 l/min

With decompression

Max. current at solenoid (1):E = 2.35 A - Special coil (9 VDC)F = 1.76 A (12 VDC)G = 0.88 A (24 VDC)

Variants (1-2):S1 = No variantL7 = emergency lever (3)P2 = Rotary emergency (3)R5 = Rotary emergency 180° (3)AJ = Coil with AMP Junior connection (1)CZ = Coil with Deutsch connection DT04-2P (1)

Serial No.

HYDRAULIC SYMBOLS

= Blind

Connector to be ordered separately, see page 103.

(1) Coils technical data, see page 109. Voltage codes are not stamped on the plate, their are readable on the coils(2) Connector to be ordered separately, see page 103;(3) Emergency (see page 46)

®

44

Page 47: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

CXQ3

IE/CXQ3002/02-2016

Q (

l/m

in)

I (%)

0

5

10

15

20

25

30

35

0 10 20 30 40 50 60 70 80 90 100

2

1

P (bar)Q

(l/

min

)

1

2

0 50 100 150 200 250

0

8

16

24

32

P (bar)

Q (

l/m

in)

1

2

0 50 100 150 200 250

0

8

16

24

32

Q (l/min)

0 10 205 15 25 30

0

5

10

15

20

P(b

ar)

Q (l/min)

0 10 205 15 25 30

0

5

10

15

20

P(b

ar)

1= CXQ3C*I...2= CXQ3C*H..

O-Ring 2-008 90Sh

3 x O-Ring 2-012 90Sh

49

19

N°4 Ø 6.5

56

59

431

3

14

BA

16

= =

= =

Ø45

161

69.5 11.580

= =

The fluid used is a mineral based oil with a viscosity of 46 mm²/s at 40°C. The tests have been carried out at with a fluid of a 40°C.

DIAGRAMS

INPUT SIGNAL FLOW

FLOW RATE BACK PRESSURE ON SECONDARY LINE

FLOW RATE BACK PRESSURE ON PRIORITY LINE

P PUMP FLOW PIN TCXQ3CT ...

P PUMP FLOW PIN TCXQ3CP ...

OVERALL DIMENSIONS CXQ3CT ...

®

45

Page 48: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

CXQ3

IE/CXQ3002/02-2016

81

.5

22

.5

max 66

120

81

.5

17

Ø 3

0

22

.5

max 63

117

123

124.5

70,5

81.5

22.5Ø

40

59

14

22

49

16

13 15

19

24

N°4 Ø 6.5

86.5

54.5

= =

= =

19.5 11.5

G 3/8"

69.5

65

11.580

36

Ø45

161

= =

4 x O-Ring 2-012 90Sh

OVERALL DIMENSIONS CXQ3CP ...

VARIANTS

Emergency P2 and P5, tightening torque max. 6÷9 Nm (CH n. 22)

“L7” Emergency lever

“P2”Rotary emergency

“R5” Rotary emergency 180°

®

46

Page 49: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FI3A

FI

3

A

**

1

IE/FI3A001/01-2015

2 x O-RING 2-012 90Sh

59

49

43

N°4 M

612

N°4 M

612

27

70

P

T

INTERMEDIATE ELEMENT

HYDRAULIC SYMBOL

FEATURES

Max. operating pressure 250 barMax. Flow 40 l/minHydraulic fluid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm²/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (filter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 0.4 kg

Intermediate element FI3A with through P and T lines. • Suggested in assemblies with more than 8 elements in order to give better

support and stability. • Maximum flow 40 l/min.• Aluminum body.

ORDERING CODE OVERALL DIMENSIONS

Intermediate element

Size

Standard connection

00 = No variantV1 = Viton

Serial No.

®

47

Page 50: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FI3L

FI

3

L

**

1

IE/ FI3L001/01-2015

2 x O-RING 2-012 90Sh

70

20

43

43,5

59

49

43

N°4 M

612

N°4 M

612

27

70

O-RING 2-010 90Sh

P

LS

T

INTERMEDIATE ELEMENT WITH LS LINE

HYDRAULIC SYMBOL

FEATURES

Max. operating pressure 250 barMax. Flow 40 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm²/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 0.4 kg

Intermediate element FI3L with through P-T and LS lines. • Suggested in assemblies with more than 8 elements in order to give better

support and stability. • Maximum fl ow 40 l/min.• Cast iron zinc plated body.

ORDERING CODE OVERALL DIMENSIONS

Intermediate element

Size

LS line

00 = No variantV1 = Viton

Serial No.

®

48

Page 51: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

1 = max 60 bar 2 = max 120 bar 3 = max 250 bar

FI

3

RP

*

*

FI3RP

IE/ FI3RP001/01-2015

1

**

1

2

3

0 15 30 45 60 75 90

0

25

50

75

100

125

150

175

200

225

250

275

300

Q (l/min)

P(b

ar)

3

2

1

0 15 30 45 60 75 90

0

5

10

15

20

25

30

35

40

Q (l/min)

P(b

ar)

0 15 30 45 60 75 90

3

2

1

0

25

50

75

100

125

150

175

200

225

250

275

300

Q (l/min)

P(b

ar)

2 x O-RING 2-012 90ShO-RING 2-010 90Sh

55

61,5 max

70 max

90

C

V

39

49

59

43

N°4 Ø 6,5

21

8 19,5

49

P

T

LS

M

INTERMEDIATE ELEMENT WITH PRESSURE REDUCING VALVE

FEATURES

Max. operating pressure 250 barMax. Flow 40 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 0.7 kg

(*) The minimum permissible setting pressure depending on the spring: see curves.

Intermediate element FI3RP provide a pilot-operated pressure reducing valve CVR20 • Test coupling• Feed a secondary branch of a circuit at a lower pressure, guaranteeing

minimum variation of the set pressure with fl ow alterations.• Manual adjustment with a grub screw or plastic knob. • Maximum fl ow 40 l/min.• Aluminum body.

ORDERING CODE

OVERALL DIMENSIONS

Pressure reducing valve (CVR20...)Setting range (*):Spring 1Spring 2Spring 3

max 60 barmax 120 barmax 250 bar

Intermediate element

Size

Pressure reducing valve

Adjustment:M = Plastic knobC = Grub screw

Setting ranges1 = max. 60 bar (white spring)2 = max. 120 bar (yellow spring)3 = max. 250 bar (green spring) 00 = No variantV1 = Viton

Serial No. C = Grub screwM = Plastic knob

PRESSURE-FLOW OF RELIEVING MIN.SETTING PRESSURE PRESSURE-FLOW RATE

Fluid used: mineral based oil with viscos-ity 46 mm²/s at 40°C.

HYDRAULIC SYMBOL

Threaded test coupling M16x2

®

49

Page 52: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

CDC3R

IE/CDC3R002/02-2016

CDC

3

C

02

**

2

*

R

E

0 10 20 305 15 25

0

50

100

150

200

250

P(b

ar)

Q (l/min)

1

2

3

4

0 5 10 15 20 25 30

0

2

4

6

8

10

12

P(b

ar)

Q (l/min)

T

P

DIRECTIONAL CONTROL VALVE CONNECTION B-P FOR INTERMEDIATE ELEMENT FI3BP

Connector to be ordered separately, see page 103.

FEATURES

Max. pressure ports P/A/B/T 250 barMax. Flow 30 l/minMax excitation frequency 3 HzDuty cycle 100% EDHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 1.50 kg

ORDERING CODE

Directional control valve (with A09 coil)

Size

Body type

Electrical operator

Spool (tab.1)

Mounting (tab.1)

Voltage (tab.2)

Variants (tab.3)

Serial No.

HYDRAULIC SYMBOL

PRESSURE DROPS

Curve Connections4 P A4 P B3 A T3 B T2 P T1 P/T passanti

Fluid used: mineral based oil with viscosity 46 mm²/s at 40°C.

LIMITS OF USE

The tests have been carried out with so-lenoids at operating temperature and a voltage 10% less than rated voltage with a fl uid temperature of 50 C°. The fl uid used was a mineral oil with a viscosity of 46 mm²/s at 40 degrees C. The values in the diagram refer to tests carried out with the oil fl ow in two directions simul-taneously (e.g. from P to A and at the same time B to T).

In the cases where valves 4/2 and 4/3 are used with the fl ow in one direc-tion only, the limits of use could have variations which may even be nega-tive. The tests were carried out with a counter-pressure of 2 bar at T port.

Directional control valve CDC3R module with body type R can be assembled with intermediate module FI3BP, to defi ne an hydraulic scheme that can select the functions ahead or behind this module.As shown in the example scheme, when the coil on side a is energised the fl ow is delivered to the sections behind this module CDC3R, instead when the coil on side b is energised the fl ow is delivered to the sections ahead.• Emergency control.• Coils protection IP65 • Power supply DC or AC (with rectifi er).• Standard connectors DIN 43650 ISO 4400, AMP Junior, fl ying leads and

Deutsch• Maximum fl ow until 30 l/min.• Cast iron zinc plated body.

®

50

Page 53: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

CDC3R

IE/CDC3R002/02-2016

BA

BA

CDC3R FI3BP

P

T T

178.5

69.5

49N°4 6.5∅

59

16

13

24

19

25

55

81

.5

= =

= =

==

==

P

1009A

T

2 x O-Ring 2-012 90Sh

46

==

10.5

Two solenoids,spring centred “C” Mounting

Code Covering Transient position

02 -

Code Variant

S1 No variant

SV Viton

LF Emergency control lever (see page 34)

LR Emergency control lever 180° rotated (see page 34)

ES Emergency button (see page 34)

P2 (7) Rotary emergency button (see page 34)

R5 (7) Rotary emergency b. 180° (see page 34)

3T First elem. for series connec.

AJ (8) AMP Junior connection (see page 105)

FL (8) Coil with flying leads 250 mm (see page 105)

LD (8) Coil with flying leads 130 mm and integrated diode (see page 105)

CX (8) Deutsch connecection with bidirectional diode (see page 105)

(1) Special voltage(2) With rectifier: 115 VAC/50Hz - 120 VAC/60Hz(3) With rectifier: 230 VAC/50Hz - 240 VAC/60Hz(4) Performance are guaranteed only using valves completed with coil(5) Connector to be ordered separately, see page 103; Coils technical data, see page 105; Voltage codes are not stamped on the plate, their are readable on the coils(6) Other variants available on request(7) Tightening torque max. 6÷9 Nm (CH n. 22)(8) Available in 12V or 24V DC voltage only

Tab.1 - Standard spools Tab.3 - Variants (5-6)

Tab.2 - Coils A09 voltage (5)

Code Voltage Max. winding temperature(Ambient temperature 25°C)

Rated powerW

Resistance @ 20°C (Ohm) ±7%

L 12 Vdc 123 °C 27 5.3

M 24 Vdc 123 °C 27 21.3

N (1) 48 Vdc 123 °C 27 85.3

Z (2) 102 Vdc 123 °C 27 392

P (1) 110 Vdc 123 °C 27 448

X (4) 205 Vdc 123 °C 27 1577

W (4) Without coils

OVERALL DIMENSIONS

Manual emergency

ORDERING CODE

EXAMPLE WITH VALVE CDC3R AND INTERMEDIATE ELEMENT FI3BP

®

51

Page 54: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FI3BP

FI

3

BP

**

1

IE/ FI3BP001/01-2015

2 x O-RING 2-012 90Sh

59

49

43

70

11

10,5

60

35

B

P

B

T

P

INTERMEDIATE ELEMENT FOR VALVE CDC3R

HYDRAULIC SYMBOL

FEATURES

Max. operating pressure 250 barMax. Flow 40 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm²/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 0.4 kg

Intermediate element FI3BP for valve CDC3R to connect B to P lines• Maximum fl ow 40 l/min.• Aluminum body.

ORDERING CODE OVERALL DIMENSIONS

Intermediate element

Size

For valve CDC3R

00 = No variantV1 = Viton

Serial No.

®

52

Page 55: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FU3

FU

3

*

00

2

IE/FU3002/01/2011

FU3*002 FU3002

FU3*002

FU3002

70

70

35

49

49

T

59

59

n. 4 fori Ø 6.5

n. 4 fori Ø 6.5

n. 2 M6

14

11

11

15

20

43

43

60

60

30

12

T

P

T

P

OUTLET MODULE UNITS

HYDRAULIC SYMBOLS

FEATURES

Max. operating pressure 250 barMax. Flow 40 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 0.2 kg

Outlet module units FU3.• Threaded ports (T) sizes G3/8” or 9/16”-18UNF.• Outlet modules without ports only for parallel connections• Maximum fl ow 40 l/min.• Aluminum body.

ORDERING CODE

OVERALL DIMENSIONS

Otulet module unit

Size Port size:For outlet module without ports is not required (only for parallel style)1 = G3/8”2 = 9/16”-18UNF No variant

Serial No.

®

53

Page 56: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FUT3

IE/ FUT3001/01-2015

FUT

3

3

00

1

59

49

70

29

25

84,5

G 1/4"

G 1/4"

45

T

P

M

OUTLET MODULE UNITS WITH SIDE PORTS

HYDRAULIC SYMBOLS

FEATURES

Max. operating pressure 250 barMax. Flow 40 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 0.4 kg

Outlet module units FUT with side ports.• Threaded ports (T) sizes G1/4”• Maximum fl ow 40 l/min.• Aluminum body.

ORDERING CODE OVERALL DIMENSIONS

Otulet module unit

Size Port size:3 = G1/4”

No variant

Serial No.

®

54

Page 57: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FUS3

IE/FUS3001/01-2015

FUS

3

1

00

1

59

49

55

43

101

24.5

45.5

70

G 3/8"

35

38

Q (l/min)

0 10 20 30 40

0

5

10

15

20

P(b

ar)

A A1

A1 A

CD3S...

CDC3S..

FUS

A1

A

BP

T

A B

BA

AB

O

OUTLET MODULE UNITS WITH OVERCENTER AND TOP PORT

HYDRAULIC SYMBOLS

FEATURES

Max. operating pressure 250 barMax. Flow 40 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 0.7 kg

Outlet module FUS3 includes an overcenter valve to control the movement of a cylinder end connected to port A1.• Threaded ports (A1) sizes G3/8”• Maximum fl ow 40 l/min.• Aluminum body.

ORDERING CODE

OVERALL DIMENSIONS

Outlet module units with overcenter and top port

Size Port size:1 = G3/8”

No variant

Serial No.

PRESSURE DROPS

Outlet module for directional control valve CDC3 and CD3 body “S” (see pages 25 and 35 ).

®

55

Page 58: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

IE/ BANK-COMP/02-2015

T

P

LS

LS

BA

T

P

LS

LS

BA

CFS3C.03 ..

PRE AND POST COMPENSATED VALVES

Patented

CXDH.3 proportional CDH.3 on/off

A pressure compensated valve maintains a constant fl ow rate across the main spool regardless of the load induced pressure, therefore the movement speed of actuator is not affected by load. Local compensa-tor on every section allows simultaneous movement of multiple func-tions.Compensated valves can be of two types: pre-compensated or post-compensated.

PRE-COMPENSATED VALVE CXDH3-CDH3• Compact and simple solution• Proportional control with valves CXDH3 or ON/OFF control with

valves CDH3• Available pressure rielief LSa-LSb valves on every working section• Valve body with the same interface of other bankable valves (for

example ON/OFF valves type CD3-CDC3 and CD5)• If the total amount of fl ow required by single function exceed the

available pump fl ow (fl ow saturation) then the function with lower load will have priority, and function with higher load will stop

POST-COMPENSATED VALVE (FLOW SHARING) CFS3• If fl ow saturation occurs then the function will proportionally re-

duce the fl ow (Flow Sharing) and will continue the movement• This solution permits high effi ciency and energy saving• Valve body with the same interface of other bankable valves (for

example ON/OFF valves type CD3-CDC3 and CD5)

®

56

Page 59: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

BA

LS

BA

LS

P

T

P1 LS GLS

T

Amm

Bmm

Cmm

Dmm

2 104 171 209 2213 150 217 255 2674 196 263 301 3135 242 309 347 3596 288 355 393 4057 334 401 439 4518 380 447 485 497

IE/BANK-COMP/02-2015

2 x M6 - 6H 2 x M6 - 6H12 12

951

22.5

99.5

D

C

B

39 A

54

54

90 117.5

(5)

32

7

10

T

P

T

LS

P1

C

951

33,5

A

B

54

70

196,21

249,5

2xM6 9 2xM6 9

Amm

Bmm

Cmm

2 134 104 1923 180 150 2384 226 196 2845 272 242 3306 318 288 3767 364 334 4228 410 380 468

A B

T

GLSLSP1

P

X

T

PRE AND POST COMPENSATED VALVES

CXDH3 proportional valves with FEH30PQ inlet module for Fixed Displacement pump

tighten the screws to a torque of 10 Nm

fixing feet available on request

Noelements

fixing holes mounting without fixing feet

tighten the screws to a torque of 10 Nm

fixing feet available on request

fixing holes mounting without fixing feet

Noelements

CXDH3 Flow Sharing valves with FEH30PQ inlet module

®

57

Page 60: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

IE/BANK-COMP/02-2015

1

4

5

6

97

8

2

3

11

14

14

15

16

16

13

12

10

Composition form

How to orderTo order the assembly, specify the codes in progressive order (inlet, valves, outlet, mounting kit, feet). See example page 112.

For any further special version not shown in this catalogue, please contact our Technical Department.

Ref. Type Descriprion Page

1 FEH30PQ OPEN CENTER inlet module for fixed displacement pumps 59

2 FEH30LS CLOSED CENTER inlet module for variable displacement load sensing pumps 61

3 FEH35PQ OPEN CENTER inlet module with compensator for fixed displacement pumps 63

4 CXDH3 PROPORTIONAL pre compensated valves 65CXDH3 / CDH3 (variants) 73

5 CDH3 ON/OFF pre compensated valves 69CXDH3 / CDH3 (variants) 73

6 CXDH3 Body G-M for modular valves 65

7 CFS3 Post compensated FLOW SHARING valve High efficiency energy saving 74CFS3 (variants) 77

8 CFS3 Body G for modular valves 74

9 FUH Outlet module units 78

10 CM3F Modular elements with ports A-B 92

11 CM3M Modular max. pressure bankable valves 95

12 HSIF Interface for proportional directional valves HPV41 98

13 — Mounting kit 99

14 — Fixing feet 101

15 — Connectors 103

16 — Coils 104

SIZE 6 valves CXDH3, CDH3, CFS3 can be assembled with:- valves CDC3, CD3, CX3 (page 6);- with SIZE 10 valves CD5 (page 80);- with proportional directional valves HPV41 (see catalogue cod. DOC00079) using the interface HSIF (page 98).

To obtain the best performances, we suggest to assemble the working sections with higher flow rate near the inlet module, leaving the ones with lower flow at the end of the assembled valve.

®

58

Page 61: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FEH30

P

Q

3

C

FEH30PQ

IE/FEH30PQ002/03-2016

3

*

*

**

2

GLSLSP1

P

X

T

Open center inlet module units FEH30PQ for fi xed displacement pumps with pressure relief valve CMP-MC/MS and electrical venting valve CRP04.• Includes a pressure compensated load sensing signal bleed to minimize

system losses even at high operating pressures. Signal bleed can be closed in case it not required.

• Manual adjustment with a grub screw. • Threaded ports P-T sizes G1/2”• Maximum fl ow 80 l/min.• Cast iron zinc plated body.

Inlet module units with pressure relief valve

Electrical venting valve

Pressure compensator element

Size

Ports G1/2”

Adjustment: C = Grub screw

Setting ranges: 1 = 35 ÷ 90 bar2 = 75 ÷ 190 bar3 = >150 bar

Voltage venting valve (1):L = 12 VdcM = 24 VdcN = 48 Vdc0 = Without electrical venting valve (plugged)

Variants (1-2):S1 = No variantsSV = VitonPY = Push button emergency (3)PS = Rotary emergency (3) AJ = AMP Junior connection 22W (see page 104)CX = Deutsch connect. bidirectional diode (see page 104)

Serial No.

OPEN CENTER INLET MODULE FOR FIXED DISPLACEMENT PUMPS

ORDERING CODE

FEATURES

Max. operating pressure 300 barSetting ranges for pressure relief valve Spring 1: 35 ÷ 90 bar

Spring 2: 75 ÷ 190 barSpring 3: >150 bar

Max. fl ow 80 l/min (see charateristic curves)

Fluid viscosity 10 ÷ 500 mm²/sMax LS bleed fl ow 0.5 l/min*Fluid temperature -25°C ÷ 75° CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 2.9 kgMax. excitation frequency 2 HzDuty cycle 100% EDType of protection (in relation to the connection used) IP65

HYDRAULIC SYMBOL

CHARACTERISTIC CURVE

To obtain a correct compensation the inlet fl ow must be 8% greater the sum of the regulated fl ows

Inlet module Pressure Drops

(1) Coils technical data, see page 104) Voltage codes are not stamped on the plate, their are readable on the coils(2) Connector to be ordered separately, see page 103; Other variants available on request.(3) Emergency (see page 60

Connector to be ordered separately, see page 103.

* Bleed fl ow rate is subtracted to the energized valve working at the higher pressure. To avoid this behavior plug the bleed (see “X” on hydraulic scheme)

“X” predisposition for LS bleed plug

®

59

Page 62: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FEH30PQ

IE/FEH30PQ001/01/2011

3,5 Corsa

(Stroke)

Ø1

0

38 max

19

Ø2

0

Ø1

0

29,538.5

60.8

47.8

23.5

39

20

.5

40

.561

.5

OVERALL DIMENSIONS

holes for optional fixing feets

predisposition to plug load sensingbleed

standard emergency

VARIANTS

“PS” Emergency rotary

“PY” Emergency with push button

“AJ” AMP Junior

“CX” Deutsch with diode

®

60

Page 63: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

Q [l/min]

P[b

ar]

0 10 20 30 40 50 60 70 80 90 100

1-2-3

0

2

4

6

8

10

12

14

16

18

20

Q [l/min]

P[b

ar]

1

2

3

0 10 20 30 40 50 60 70 80 90 100

0

50

100

150

200

250

300

350

400

IE/FEH30LS001/03/2013

FEH30LS

FEH30

LS

3

*

*

**

1

*

X

LS

LS

T

P

Closed center inlet module units FEH30LS for variable displacement Load Sens-ing pumps with pressure relief valve CMP30 and a pressure compensated load sensing signal bleed to minimize system losses even at high operating pres-sures. Signal bleed can be closed in case it is not required.• Manual adjustment with a grub screw. • Threaded ports P-T sizes G1/2” or 7/8” 14UNF; LS ports, G1/4” or 7/16” 20UNF• Maximum fl ow 80 l/min.• Cast iron zinc plated body.

Inlet module units with pressure relief valve

With LS signal

Size

Ports:3 = G1/2” (P,T ports) G1/4” (LS port)4 = 7/8” - 14UNF (P,T ports) 7/16” - 20UNF (LS port)

Adjustment: M = Plastic knobC = Grub screw

Setting ranges: 1 = max 50 bar2 = max 140 bar3 = max 350 bar

Variants: 00 = No variantsV1 = Viton

Serial No.

CLOSED CENTER INLET MODULE FOR VARIABLE DISPLACEMENT LOAD SENSING PUMPS

ORDERING CODE

FEATURES

Max. operating pressure 300 barSetting ranges for pressure relief valve Spring 1: max 50 bar

Spring 2: max 140 barSpring 3: max 350 bar

Max. Flow 80 l/min (see charateristic curves)

Max LS bleed fl ow rate 0.5 l/min*

Fluid viscosity 10 ÷ 500 mm²/s

Fluid temperature -25° ÷ 75° C

Ambient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 1.9 kg

HYDRAULIC SYMBOL

PRESSURE RELIEF VALVE CURVES

Pressure Flow Minimun setting pressure

* Bleed fl ow rate is subtracted to the energized valve working at the higher pressure. To avoid this behavior close LS tap (see “X” on hydraulic scheme)

“X” Tap for LS bleed plug

®

61

Page 64: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

IE/FEH30LS001/01/2011

FEH30LS

49

67

N°4 M6 6

G1/2"

G1/2"

Ø 31

15

10.5

4770

90

2 3.8

21

39

33.5

= =

= =

17

26

12.5

G1/4"

49

73.5

N°2 M6 12

54

39

5

8

Ø 3

4.5

55.5

2 x O-RING 2-012 90Sh

1 x O-RING 2-008 90Sh

OVERALL DIMENSIONS

holes for optional fixing feets

C = Adjustment with grub screw

M = Adjustment with plastic knob

®

62

Page 65: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FEH35PQ

IE/FEH35PQ001/02-2015

FEH35

P

Q

3

C

3

*

*

**

1

0

5

10

15

20

25

30

35

40

0 10 20 30 40 50 60 70 80 90 100 110 120

Q (l/min)

P(b

ar)

GLSLSP1

P

X

T

OPEN CENTER INLET MODULE WITH COMPENSATOR FOR FIXED DISPLACEMENT PUMPS

Open center inlet module units FEH35PQ with adjustable compensator regula-tor for fi xed displacement pumps with pressure relief valve CMP-MC/MS and electrical venting valve CRP04.• Includes a pressure compensated load sensing signal bleed to minimize

system losses even at high operating pressures. Signal bleed can be closed in case it not required.

• Manual adjustment with a grub screw. • Threaded ports P G1/2”; T G3/4”• Maximum fl ow 120 l/min.• Cast iron zinc plated body.

Inlet module units with pressure relief valveand pressure compensator

Electrical venting valve

Pressure compensator element

Size

3 = Port P = G1/2” - Port T = G3/4”

Adjustment: C = Grub screw

Setting ranges: 1 = 35 ÷ 90 bar2 = 75 ÷ 190 bar3 = >150 bar

Voltage venting valve (1):L = 12 VdcM = 24 VdcN = 48 Vdc0 = Without electrical venting valve (plugged)

Variants (1-2):S1 = No variantsSV = VitonPY = Push button emergency (3)PS = Rotary emergency (3) AJ = AMP Junior connection 22W (see page 104)CX = Deutsch connect. bidirectional diode (see page 104)

Serial No.

ORDERING CODE

FEATURES

Max. operating pressure 310 barSetting ranges for pressure relief valve Spring 1: 35 ÷ 90 bar

Spring 2: 75 ÷ 190 barSpring 3: >150 bar

Setting compensator regulator 10 ÷ 19 bar

Max. fl ow 120 l/min (see charateristic curves)

Fluid viscosity 10 ÷ 500 mm²/s

Max LS bleed fl ow 0.5 l/min*

Fluid temperature -25°C ÷ 75° C

Ambient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 3.1 kg

Max. excitation frequency 2 Hz

Duty cycle 100% EDType of protection (in relation to the connection used) IP65

HYDRAULIC SYMBOL

CHARACTERISTIC CURVE

To obtain a correct compensation the inlet fl ow must be 8% greater the sum of the regulated fl ows

Pressure drops with compensator setting at 10 and 19 bar

(1) Coils technical data, see page 104) Voltage codes are not stamped on the plate, their are readable on the coils(2) Connector to be ordered separately, see page 103; Other variants available on request.(3) Emergency (see page 64

Connector to be ordered separately, see page 103.

* Bleed fl ow rate is subtracted to the energized valve working at the higher pressure. To avoid this behavior plug the bleed (see “X” on hydraulic scheme)

“X” predisposition for LS bleed plug

®

63

Page 66: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

FEH35PQ

IE/FEH35PQ001/01-2015

3,5 Corsa

(Stroke)

Ø1

0

38 max

19

Ø2

0

Ø1

0

29,538.5

60.8

47.8

23.5

39

20

.5

40

.561

.5

75 47,574 max.

95

P G1/2"

T G3/4"

49

80

4 x M6 6

43

33,5

107

10,5

7

28

38

70

54

30

2 x M6 9

8

5

P1 G1/4"LS G1/8"

2 x ORing 2-012 90Sh

1 x ORing 2-008 90Sh

OVERALL DIMENSIONS

Predisposition to plug load sensing bleed

Standard emergency

VARIANTS

“PS” Emergency rotary

“PY” Emergency with push button

“AJ” AMP Junior

“CX” Deutsch with diode

plugged plugged

Compensator settingScrew Hex. 5 Nut Hex.10

Relief valve setting Screw Hex.3 Nut Hex.10

®

64

Page 67: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

* p 8bar p 4barD 8 l/min 6 l/min2 16 l/min 12 l/min3 22 l/min 18 l/min4 35 l/min 28 l/min

IE/CXDH3001/03/2012

CXDH3

CXDH

3

*

**

*

*

*

N

*

1

**

A Oa

A B

P T

bB

A Oa

A B

P T

O

A B

P T

bB

Stackable proportional directional valves CXDH with LS signal locally compen-sated• Used for controlling fl uid direction and fl ow rate as a function of the sup-

ply current to the proportional control solenoid. • Flow regulation load indipendent. • Load compensantionis achieved by a 2 way pressure compensator wich

holds, the pressure drop constants across the proportional spool. • Emergency control.• Threaded ports or interface for modular valves• Regulated fl ow rate until 35 l/min.• Standard connectors DIN 43650 ISO 4400, AMP Junior and Deutsch• Cast iron zinc plated body.

Proportional compensated bankable valve

Size

Mounting (see table 1)

Body type:A = Ports G3/8” parallelG= Interface for modular valvesB= Ports SAE 9/16” - 18UNFL= Ports G3/8” parallel with valves LSA LSBM= Interface for modular valves with valves LSA LSB

Type of spool (1)03 =

Symmetrical fl ow path control

Flow rating

Differential pressure p8 = p 8 bar4 = p 4 bar

Max. current at solenoid (2):E = 2.35 A (9 Vdc) - Special coilF = 1.76 A (12 Vdc)G = 0.88 A (24 Vdc)

Variants (3):S1 = No variantLF/LV = Emergency control lever (see page 72)For body type G and M order LR variant (emergency lever 180° rotated)SV = VitonES = Emergency button (4)P2= Rotary emergency (4)R5 = Rotary emergency 180° (4)AJ = AMP Junior coil (see page 109)CZ = Deutsch DT04-2P coil (see page 109)

Serial No.

PROPORTIONAL PRE COMPENSATED VALVES

ORDERING CODE

FEATURES

Max. operating pressure 300 barMax. operating pressure ports T(Pressure dynamic allowed for 2 millions of cycles) 250 bar

Regulated fl ow rate (A / B ports) up to 35 l/minRelative duty cycle Continuous 100% EDType of protection (Hirschmann coil) IP 65Fluid viscosity 10 ÷ 500 mm²/sFluid temperature -20°C ÷ 75° CAmbient temperature -20°C ÷ 60°CMax. contamination level (fi lter ß10 75)

ISO 4406:1999: class 19/17/14NAS 1638: class 8

Weight with single solenoidWeight with double solenoid

2.38 kg2.77 kg

Solenoid @ 9Vdc @ 12Vdc @ 24VdcCurrent supply PWM (pulse width modulation)Max. current solenoid 2.35 A 1.76 A 0.88 ASolenoid coil resistance at 25°C (77°F) 2.25 Ohm 4.0 Ohm 16.0 OhmPWM or superimposed dither frequency 100 ÷ 150 HzResponse time

0 ÷ 100%100% ÷ 0

32 ms33 ms

40 ms33 ms

85 ms33 ms

Frequency response -3db (input signal 50% ±25% Vmax) 22 Hz 22 Hz 12 Hz

REM.S.RA.*.*. REM.D.RA.*.*. Card type control for single and double solenoid

CEP.S... Electronic amplifi er plug version for signle solenoid

MAV Electronic module for integrate control of proportional valves and ON/OFF

JMPEI0M700101 Joystick with standard handleJMPIU0M700138 Joystick Person present handleModular valves CM3P (page 93) and CM3M (page 95)

Accessories

(1) Available spool 01 A and B ports are not sealed: fl uid can escape from LS line (see hydraulic scheme).

(2) Coils technical data, see page 109 Voltage codes are not stamped on the plate, their are readable on the coils(3) Connector to be ordered separately, see page 103; Other variants available on request.(4) Emergency see page72

Connector to be ordered separately, see page 103.

Code Symbol

C

A

B

Tab.1 - Mounting

Operating specifi cations are valid for fl uid with 46 mm²/s viscosity at 40°C, using the specifi ed Dana Brevini electronic control units. (input voltage = 24V).

Patented

Calibrated diaphragms on P line, see page 102.

®

65

Page 68: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

Q [

l/m

in]

I [%]

0

5

10

15

20

25

30

35

40

0 10 20 30 40 50 60 70 80 90 100

D

2

3

4

Q [

l/m

in]

I [%]

0 10 20 30 40 50 60 70 80 90 100

0

5

10

15

20

25

30

D

2

3

4

Q (

l/m

in)

p (bar)

0

5

10

15

20

25

30

35

40

0 50 100 150 200 250 300

D

2

3

4

Q (

l/m

in)

p (bar)

0 50 100 150 200 250 300

0

5

10

15

20

25

30

D

2

3

4

IE/CXDH3001/03/2012

CXDH3

T

P

LS

LS

BA

CXDH3AA03 .. CXDH3AG03 .. CXDH3CA03 .. CXDH3CG03 ..

T

P

LS

LS

BAT T

T

P

LS

LS

BA

T

P

LS

LS

BAT T

T

P

LS

BAT T

CXDH3AM03 .. CXDH3AL03 .. CXDH3CM03 .. CXDH3CL03 ..

T

P

LS

BA

T

P

LS

BAT T

T

P

LS

BA

HYDRAULIC SYMBOLS

* Thanks to the design of the modular body (type G), an anti-shock modular valve can works same with CXDH3 valve energized or de-energized (see hydraulic symbol)

CHARACTERISTIC CURVES

The fluid used is a mineral based oil with a viscosity of 46 mm²/s at 40°C. The tests have been carried out at with a fluid of a 40°C.

I-Q curves - (Curves acquired with REM card, opening stroke) Compensation curves (curves acquired with FEH30.PQ inlet module)Differential Pressure p = 8 bar Differential Pressure p = 4 bar Differential Pressure p = 8 bar Differential Pressure p = 4 bar

®

66

Page 69: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

IE/CXDH3001/03/2012

CXDH3

13

24

24.5

16

19

59

49

69.5

229.5

80 80

30

51.5 89.5

143.5

= =

4 x O-RING 2037/2-012 N552 90ShO-RING 2018/2-008 90Sh

46

31

35

19

368

4 x Ø

5.5

4 x M

5

O-RING 2037/2-012 N552 90Sh

4 FORI Ø 6.5

4 HOLES

=

=

=

=

=

=

=

=

=

=

=

=

=

=

54

81.5

13

24

24.5

16

19

51.5

59

49

69.5

229.5

4 FORI Ø 6.5

4 HOLES

80 80

30

111

5.2

81.5

=

=

=

=

=

=

=

=

=

=

O-RING 2037/2-012 N552 90ShO-RING 2018/2-008 90Sh

30.5

29.3

4.2

4.2

46

G3/8" (*)

82.5

28.5

Body type GInterface for modular valves

OVERALL DIMENSIONS

Body type A Ports G3/8” Parallel

Coils can be rotated by 180°

Fittings, max. tightening torque 60 Nm

®

67

Page 70: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

24.5

5.2

79.5

109

154

=

=

=

=

46

80.5

28.5

45

13

24

16

19

59

4 FORI Ø 6.5

4 HOLES

80 80

30

49.5

4 x O-RING 2037/2-012 N552 90SHO-RING 2018/2-008 90 SH

30.5

G3/8

"

49

69.5

229.5=

=

=

=

=

=

=

=

IE/CXDH3001/03/2012

CXDH3

4 FORI Ø 6.5

4 HOLES

=

=

=

=

=

=

=

=

=

=

=

=

=

=

=

=

54

45

13

24

24.5

16

19

79.5

59

49

69.5

229.5

80 80

30

49.5

89.5

124.5

178.5

4 x O-RING 2037/2-012 N552 90SHO-RING 2018/2-008 90 SH

46

31

35

19

36

8

4 xØ

5.5

4 x M

5O-RING 2037/2-012 N552 90SH

Body type LPorts G3/8” parallel with valves LSA LSB

OVERALL DIMENSIONS

Body type MInterface for modular valves with valves LSA LSB

®

68

Page 71: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

IE/CDH3001/04-2017

CDH3

CDH

3

*

**

E

*

*

**

*

1

**

**

ØA ØB

T

P

LS

LS

BA

ON/OFF PRE COMPENSATED VALVES

ON/OFF Compensated Valves CDH3 with single or double solenoid, LS signal locally compensated.• Used for controlling fl uid direction and fl ow rate. • Flow rate controlled by the valve predefi ned by a holed calibrated washer

screwed into the port A and/or B. • Flow regulation load independent . Load compensantion is achieved by

a 2 way pressure compensator wich holds, the pressure drop constants across the proportional spool.

• Threaded ports G3/8”• Emergency control.• Standard connectors DIN 43650 ISO 4400, AMP Junior and Deutsch• Cast iron zinc plated body.

On/Off compensated bankable valve

Size

Body type:A = Ports G3/8” parallel

Electrical operator

Spool (see table 1)

Mounting (see table 2)

Holed washer on port A (see table 3)

Holed washer on port B (see table 3)Omit if equal to screw on port A

Differential pressure p8 = p 8 bar4 = p 4 bar

Voltage (see table 4)

Variants (see table 5)

Serial No.

ORDERING CODE

FEATURES

HYDRAULIC SYMBOL

Max. operating pressure ports P/A/B 300 barMax. operating pressure ports T(Pressure dynamic allowed for 2 millions of cycles) 250 bar

Max fl ow See table 3Max excitation frequency 3 HzDuty cycle 100% EDType of protection (Hirschmann coil) IP 65Fluid viscosity 10 ÷ 500 mm²/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight with single solenoidWeight with double solenoid

2.38 kg2.77 kg

General fl ow tolerance ±10%Operating specifi cations are valid for fl uid with 46 mm²/s viscosity at 40°C, using the specifi ed Dana Brevini electronic control units.

Connector to be ordered separately, see page 103.

Calibrated diaphragms on P line, see page 102.

®

69

Page 72: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

A

B

a b

A Oa

A B

P T

bB

a b

a b

a b

A Oa

A B

P T

a

a

a

a

a

O

A B

P T

bB

b

b

b

b

b

A O

A B

P T

b

Oa

A B

P T

B

A Oa

A B

P T

bB

A Oa

A B

P T

O

A B

P T

bB

IE/CDH3001/04-2017

CDH3ORDERING CODE

CodeFlow (l/min)

p = 8 bar p = 4 bar10 1.7 1.315 4.0 3.020 7.5 5.525 10.0 8.030 14.2 9.535 17.2 11.540 18.0 13.545 22.5 17.550 26.0 19.599 without holed washer

Tab.3 - Holed washer on port A / B

Other flow rates available on request

Tab.1 - Spool

Code Symbol

C

E

F

G (1)

H (1)

Tab.2 - Mounting

Interchangeable holed washer into fittings ports

(1) Specials with price increasing(2) On spool 01 and 04 A and B ports are not sealed: fluid can escape

from LS line (see hydraulic scheme).(3) Special voltage(4) With rectifier: 115 VAC/50Hz - 120 VAC/60Hz(5) With rectifier: 230 VAC/50Hz - 240 VAC/60Hz(6) Performance are guaranteed only using valves completed with coil(7) Connector to be ordered separately, see page 103; Coils technical data, see page 106 - 107; (8) Other variants available on request. All the variants are considered without

connectors. (9) Tightening torque max. 6÷9 Nm (CH n. 22)(10) Available in 12V or 24V DC voltage only.

Two solenoids, spring centred “C” Mounting

Code Covering Transient position

01 + (2)

02 -

03 +

04 (1) - (2)

One solenoid, side A “E” Mounting

Code Covering Transient position

01 + (2)

02 -

03 +

04 (1) - (2)

15 -

One solenoid, side B “F” Mounting

Code Covering Transient position

01 + (2)

02 -

03 +

04 (1) - (2)

15 -

Code Voltage Max. winding temperature(Ambient temperature 25°C)

Rated powerW

Resistance @ 20°C (Ohm) ±10%

L 12 Vdc 110 °C 30 4.8

M 24 Vdc 110 °C 30 18.8

V (3) 28 Vdc 110 °C 30 25.6

N (3) 48 Vdc 110 °C 30 75.2

Z (4) 102 Vdc 110 °C 30 340

P (3) 110 Vdc 110 °C 30 387

X (5) 205 Vdc 110 °C 30 1375

W (6) Without coils

Tab.5 - Variants (7 - 8)

Code Variant

S1 No variant

SV Viton

LF Emergency control lever (see page 72)

LR Emergency control lever180° rotated (vedi pagina 72)

ES Emergency button (vedi pagina 72)

P2 (9) Rotary emergency button (vedi pagina 72)

R5 (9) Rotary emergency b. 180° (vedi pagina 72)

AJ (10) AMP Junior connection (vedi pagina 106)

AD (10) AMP Junior and integr diode (vedi pagina 106)

SL (10) Coil with flying leads 175 mm (vedi pagina 106)

CZ (10) Coil with Deutsch DT04-2P (vedi pagina 107)

CX (10) Deutsch DT04-2P connection and integr diode (see page 107)

Tab.4 - Coils D15 voltage (7)

®

70

Page 73: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

IE/CDH3001/04-2017

CDH3

24

19

24.5

59

49

13

16

30

51.5

111

81.5

82.5

5.2

= =

= =

O-RING 2037/2-012 N552 90ShO-RING 2018/2-008 90Sh

80 8069.5

229.5

29.3

30.5

G 3/8"

4.2

4.2

= =

= =

81.5

46

29.5

= =

OVERALL DIMENSIONS

Fittings, max. tightening torque 60 Nm

®

71

Page 74: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

IE/CXDH3-CDH3-VAR/03-2016

28° 28°

7715

8.5

26.5

282.5202.5

28°

28°

137

28°

28°

28°

28°

77

202

137

26.5

282.5202.5

“LF”, “LR” AND “LV” VARIANTS - EMERGENCY CONTROL LEVER

Thanks to his fl exibility, the component is designed to be inserted between the valve body and the spool, providing total interchangeability between the different types of solenoid body valves manufactured by Dana Brevini (*). The control can be used as an emergency device in the event of power cuts.

* Max fl ow of proportional valves can be reduced compared to versions without emergency control lever when electrical operated. Max fl ow of proportional valves lever operated is increased compared to the max fl ow given when valves are electri-cal operated.

LF Variant (CXDH3 / CDH3)

LR Variant (CXDH3 / CDH3)

Spool 01 available on request

CXDH3 / CDH3 (variants)

Max operating pressure port Tdynamic 160 bar

static 210 barMounting type Var. LF/LRMounting type Var. LV

C - B - F - HC-A

Spools type 01-02-03-0416-17-66

Weight with single solenoidWeight with double solenoid

3.34 kg3.73 kg

LF VariantBody L (CXDH3)

LR VariantM Body (CXDH3)

HYDRAULIC SYMBOL

Var. LF/LR lever on the side A:

Var. LV lever on the side B:

LV Variant (CXDH3 / CDH3)

®

72

Page 75: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

IE/CXDH3-CDH3-VAR/02/2013

81

.5

22

.5

98.5

Ø 3

2

81

.5

22

.5

max 66

120

81

.5

17

Ø 3

0

22

.5

max 63

117

54.3

53.766.7

66.5

54.3

53.7

54.3

Emergency P2 and P5, tightening torque max. 6÷9 Nm (CH n. 22)

OTHER VARIANTS

“ES” Manual emergency

“P2”Rotary emergency

“AJ” AMP Junior“AD” AMP Junior + Diode

“CZ” Deutsch DT04-2P

“SL” Flying leads

“R5” Rotary emergency 180°

CXDH3 / CDH3 (variants)USE OF HSIF INTERFACE WITH MODULAR VALVES CXDH3/CDH3, WITH EMERGENCY LEVER

Distributor HPV41 right (DX, standard)- Order modular valves CXDH3/CDH3 variant LV, with emergency lever on the side B

Distributor HPV41 left (SX)- Order modular valves CXDH3/CDH3 variants LF / LR, with emergency lever on side A- In this case it is not possible to mount the modular valve CXDH3/CDH3 variant LF / LR as the first element after HSIF interface.

®

73

Page 76: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

CFS3

IE/CFS3001/03-2017

CFS

3

*

**

*

*

N

*

1

**

A Oa

A B

P T

bB

A Oa

A B

P T

O

A B

P T

bB

POST COMPENSATED FLOW SHARING VALVE HIGH EFFICIENCY ENERGY SAVING

High effi ciency energy saving valve FLOW SHARING• High effi ciency energy saving valve• Compact dimensions• Venting valves can be adopted to de-pilot pressure compensators on port

A and/or B• Valve’s body with the same interface of all bankable valves range, so can

be assembled with all existings valves, precompensated (CXDH3) includ-ed

• Cast iron zinc plated body.

FLOW SHARING valve

Size

Mounting (see table 1)

Body type:A = Ports G3/8” parallelP = Ports G1/2” parallelQ = Ports SAE8 3/4”-16UNF parallelG= Interface for modular valves

Spool type (1)03 =

Symmetrical fl ow path control

Nominal fl ow rating

Max. current at solenoid (2):E = 2.35 A (9 Vdc) - Special coilF = 1.76 A (12 Vdc)G = 0.88 A (24 Vdc)

Variants (3):S1 = No variantLF/LV = Emergency control lever (4)For body type G order LR variant (emergency lever 180° rotated)SV = VitonES = Emergency button (4)P2= Rotary emergency (4)R5 = Rotary emergency 180° (4)AJ = AMP Junior coil (see page 109)CZ = Deutsch DT04-2P coil (see page 109)

Serial No.

(1) Available spool 01 A and B ports are not sealed.(2) Coils technical data, see page 109 Voltage codes are not stamped on the plate, their are readable on the coils(3) Connector to be ordered separately, see page 103; Other variants available on request.(4) Emergency see page77(5) Only for emergency lever (6) With FH35PQ you can set a p variable (from LS and P); with FEH30PQ the p is

fi xed at 13 bar

ORDERING CODE

Max. operating pressure 310 barMax. operating pressure ports T(Pressure dynamic allowed for 2 millions of cycles) 250 bar

Regulated fl ow rate (A / B ports) (6)up to 55 l/min ( p 14 bar)up a 60 l/min ( p 18 bar)

Relative duty cycle Continuous 100% EDType of protection (Hirschmann coil) IP 65Fluid viscosity 10 ÷ 500 mm²/sFluid temperature -20°C ÷ 75° CAmbient temperature -20°C ÷ 60°CMax. contamination level (fi lter ß10 75)

ISO 4406:1999: class 19/17/14NAS 1638: class 8

Weight with single solenoidWeight with double solenoid

3.70 kg4.20 kg

Solenoid @ 9Vdc @ 12Vdc @ 24VdcCurrent supply PWM (pulse width modulation)Max. current solenoid 2.35 A 1.76 A 0.88 ASolenoid coil resistance at 25°C (77°F) 2.25 Ohm 4.0 Ohm 16.0 OhmPWM or superimposed dither frequency 100 ÷ 150 HzResponse time

0 ÷ 100%100% ÷ 0

32 ms33 ms

40 ms33 ms

85 ms33 ms

Frequency response -3db (input signal 50% ±25% Vmax) 22 Hz 22 Hz 12 Hz

Operating specifi cations are valid for fl uid with 46 mm²/s viscosity at 40°C, using the specifi ed Dana Brevini electronic control units. (input voltage = 24V).

REM.S.RA.*.*. REM.D.RA.*.*. Card type control for single and double solenoid

CEP.S... Electronic amplifi er plug version for signle solenoid

MAV Electronic module for integrate control of proportional valves and ON/OFF

JMPEI0M700101 Joystick with standard handleJMPIU0M700138 Joystick Person present handleModular valves CM3P (page 93) and CM3M (page 95)

Accessories

Code Symbol

C

A

B

Tab.1 - Mounting

Connector to be ordered separately, see page 103.

FEATURES

Calibrated diaphragms on P line, see page 102.

* p 14 bar from P to A,B1 8 l/min2 16 l/min3 25 l/min4 40 l/min

5 (5) 55 l/min

®

74

Page 77: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

IE/CFS3001/03-2017

CFS3

Q (

l/m

in)

I (%)

0

10

20

40

30

50

60

0 10 20 30 40 50 60 70 80 90 100

1

2

3

4

5

1 8 l/min2 16 l/min3 25 l/min4 40 l/min5 55 l/min

CFS3C.03 .. CFS3A.03 .. CFS3B.03 ..

CFS3C.01 .. CFS3A.01 .. CFS3B.01 ..

Q (

l/m

in)

p (bar)

0

10

20

40

30

50

60

0 50 100 150 200 250 300

1

2

3

4

5

HYDRAULIC SYMBOLS

CHARACTERISTIC CURVES

Spool 01 mounting C-A-B

Spool 03 mounting C-A-B

Curves

Flow

Q-I curves with p 14bar Compensation curves

®

75

Page 78: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

IE/CFS3001/03-2017

CFS3

69,5

102,3

32,8

19

35

31

36

4x M

5

2x

Ø

5,5

2x Ø 4,5

8

A = G3/8” L= 30,5 P = G1/2” L=38,00 Q = SAE8 3/4”-16UNF L=38,00

49

N°4

59

70,5

32,8

103,3

21

24

8

17,5

19,5

89,5 8080

249,5

O-RING 2018/2-008 90Sh

46

6,5

O-RING 2037/2-012 90Sh

LA B

OVERALL DIMENSIONS

Fittings, max. tightening torque 60 Nm

Body type GInterface for modular valves

BodyA = Ports G3/8” parallel P = Ports G1/2” parallelQ = Ports SAE8 3/4”-16UNF parallel

®

76

Page 79: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

1

IE/CFS3-VAR/01-2015

28°

28°

302,5

136

65,6

26,5

103,3

89,5 80

28°

28°

302,5

136

28°

28°

173.5

81

.5

22

.5

98.5

Ø 3

2

81

.5

22

.5

max 66

120

81

.5

17

Ø 3

0

22

.5

max 63

117 54.3

53.766.7

66.5

54.3

CFS3 (variants)“LF”, “LR” AND “LV” VARIANTS - EMERGENCY CONTROL LEVER

* Max fl ow of proportional valves can be reduced compared to versions without emergency control lever when electrical operated. Max fl ow of proportional valves lever operated is increased compared to the max fl ow given when valves are electri-cal operated.

LF Variant

LR Variant

Max operating pressure port Tdynamic 160 bar

static 210 barMounting type Var. LF/LRMounting type Var. LV

C - B C - A

Spools type 01 - 03

HYDRAULIC SYMBOL

Var. LF/LR lever on the side A:

Var. LV lever on the side B:

LV Variant

OTHER VARIANTS

“ES” Manual emergency

“P2”Rotary emergency

“AJ” AMP Junior“AD” AMP Junior + Diode

“CZ” Deutsch DT04-2P

“R5” Rotary emergency 180°

Emergency P2 and P5, tightening torque max. 6÷9 Nm (CH n. 22)

Thanks to his fl exibility, the component is designed to be inserted between the valve body and the spool, providing total interchangeability between the different types of solenoid body valves manufactured by Dana Brevini (*). The control can be used as an emergency device in the event of power cuts.

®

77

Page 80: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

190

39

50

43

70

49

59

4 x Ø 6.5

G3/4"

= =

= =

= =

30

7

54

2 x M6 - 6H

2 x M6 - 6H

12

12

= =

IE/FUH3001/01/2011

FUH

FUH

3

5

1

00

P

LS

T

OUTLET MODULE UNITS

Outlet module units FUH• Threaded ports (T) sizes G3/4”• Only for parallel connections• Maximum fl ow 80 l/min.• Cast iron zinc plated body.

Outlet module unit

Size

Port size:5 = G3/4”

00 = No variants

Serial No.

ORDERING CODE FEATURES

Max. operating pressure 300 bar

Max. Flow 80 l/min

Hydraulic fl uids Mineral oils DIN 51524

Fluid viscosity 10 ÷ 500 mm²/s

Fluid temperature -25° ÷ 75° C

Ambient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 1.2 kg

HYDRAULIC SYMBOL

OVERALL DIMENSIONS

®

78

Page 81: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

2

SIZE 10

ON/OFF VALVES

®

79

Page 82: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

2

2 x M6 - 6H

2 x M6 - 6H

12

12

D

C

10

32

7

Ch

./H

ex.

10

97

.5

78 90

.5

46

ON/OFF VALVES

Overall dimensions with CD5 valves

Introduction• Compact bankable valves with flow rates up to 80 l / min;• High efficiency coils;

• Available ON/OFF directional control bankable valve;• Available for parallel circuits;• Assemblable with SIZE 6 valves.

No.elements

Inlet module

FE5 FE305C

mmD

mmC

mmD

mm2 201 189 221 209

3 247 235 267 255

4 293 281 313 301

5 339 327 359 347

6 385 373 405 393

fixing holes mounting without fixing feet

®

80

Page 83: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

2

IE/BANK-SIZE10/00-2017

8

1

6

5

2

3

4

6

5

7

Composition form

How to orderTo order the assembly, specify the codes in progressive order (inlet, valves, outlet, mounting kit, feet). See example page 114.

For any further special version not shown in this catalogue, please contact our Technical Department.

Ref. Type Description Page

1 FE5 Inlet module units no pressure relief valve 82

2 FE305 Inlet module units with pressure relief valve 83

3 CD5 Directional control bankable valve 85

4 FU5 Outlet module units 88

5 — Mounting kit 99

6 — Fixing feet 101

7 — Connectors 103

8 — Coils 108

SIZE 10 valves CD5 can be assembled with:- valves CDC3, CD3, CX3 (page 6);- valves CXDH3, CDH3, CFS3 (page 56);

To obtain the best performances, we suggest to assemble the working sections with higher flow rate near the inlet module, leaving the ones with lower flow at the end of the assembled valve.

®

81

Page 84: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

2

FE5

FE

5

3

**

1

IE/FE5001/00-2017

P

T

2 OR 2-013 90Shx

49 N°2 M6 9

12

20

52

10.5

35

32

35

70

30

70

Ø14

Ø9

8 54

16

N°2 M6 12

INLET MODULE UNITS NO PRESSURE RELIEF VALVE

HYDRAULIC SYMBOL

FEATURES

Max. operating pressure 310 barMax. Flow 80 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm²/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 0.94 kg

Module units FE5 no pressure relief valve. • Threaded ports (P and T), G1/2“• Maximum fl ow 80 l/min• Cast iron zinc plated body.

Inlet module unitno pressure relief valve

Size

Port sizes:3 = G1/2” 00 = No variantV1 = Viton

Serial No.

ORDERING CODE OVERALL DIMENSIONS

®

82

Page 85: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

2

1 = max 50 - bar - 2 = max 140 bar - 3 = max 350 bar

FE30

5

3

*

*

**

1

FE305

IE/FE305001/00-2017

Q [l/min]

P[b

ar]

0 10 20 30 40 50 60 70 80 90 100

1-2-3

0

2

4

6

8

10

12

14

16

18

20

Q [l/min]

P[b

ar]

1

2

3

0 10 20 30 40 50 60 70 80 90 100

0

50

100

150

200

250

300

350

400

P

M

T

INLET MODULE UNITS WITH PRESSURE RELIEF VALVE

HYDRAULIC SYMBOL

PRESSURE-FLOW RATE

Fluid used: mineral based oil with viscosity 46 mm²/s at 40°C.

FEATURES

Max. operating pressure 310 barMax. Flow 80 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 1.85 kg

(*) The minimum permissible setting pressure depending on the spring: see curves.

Module units FE305 with CMP30 adjustable pressure relief valve.• Manual adjustment with a grub screw or plastic knob. • Threaded ports P-T sizes G1/2” • Maximum fl ow 80 l/min. • Cast iron zinc plated body.

ORDERING CODE

Inlet module unit (up to 80 l/min)with pressure relief valve

Size

Port sizes:3 = G1/2” Adjustment:M = Plastic knobC = Grub screw

Setting ranges1 = max. 50 bar (white spring)2 = max. 140 bar (yellow spring)3 = max. 350 bar (green spring) 00 = No variantV1 = Viton

Serial No.

MIN.SETTING PRESSURE

Pressure relief valve (CMP30...)Setting range (*):Spring 1Spring 2Spring 3

max 50 barmax 140 barmax 350 bar

Pressure Flow Minimun setting pressure

®

83

Page 86: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

2

FE305

12 1

7

47

30

10.5 49

35

17

50

85

M6 6

70

116.5

125

Ø 14 N°2 OR 2-013 90Sh

M PORT

G1/4"

(PLUGGED)

5 60

25

M6 12

25

50

C

M

IE/FE305001/00-2017

OVERALL DIMENSIONS

C = Grub screwM = Plastic knob

®

84

Page 87: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

2

CD5

IE/CD5001/00-2017

CD

5

*

**

**

1

*

N

E

DIRECTIONAL CONTROL BANKABLE VALVE

Directional control bankable valve CD5 with single or double solenoid.• Centring achieved by means of calibrated length springs which immedi-

ately reposition the spool in the neutral position when the electrical signal is shut off.

• Emergency control.• Threaded ports sizes G1/2”• Coils protection IP66 • Standard connectors DIN 43650 ISO 4400 and Deutsch• Maximum fl ow until 80 l/min.• Cast iron zinc plated body.

FEATURES

Max. pressure ports P/A/B/T 310 barMax. pressure port T 250 barMax. Flow 80 l/minMax excitation frequency 3 HzDuty cycle 100% EDHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight with one solenoidWeight with two solenoids

2.68 kg3.07 kg

ORDERING CODE

Directional control bankable valve

Size

Body parallel, ports G1/2” Electrical operator

Spool (tab.2)

Mounting (tab.3)

Voltage (tab.4)

Variants (tab.5)

Serial No.

®

85

Page 88: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

2

CD5

1

2

0 10 20 30 40 50 60 70 80

2

0

4

6

8

10

12

14

P(b

ar)

Q (l/min)

1

3

0 10 20 30 40 50 60 70 80

50

0

100

150

200

250

300

350

P(b

ar)

Q (l/min)

1 = P > A,B2 = A,B > T

IE/CD5001/00-2017

Two solenoids,spring centred “C” Mounting

Code Covering Transient position

01 +

03 +

One solenoid, side A “E” Mounting

Code Covering Transient position

01 +

03 +

Code Symbol

C

E

F

One solenoid, side B “F” Mounting

Code Covering Transient position

01 +

03 +

Code Variant

S1 No variant

SV Viton

ES Emergency button (see page 87)

P2 (3) Rotary emergency button (see page 87)

R5 (3) Rotary emergency b. 180° (see page 87)

CZ Deutsch DT04-2P - 40W connection (see page 108)

(1) Connector to be ordered separately, see page 103 Coils technical data, see page 108 Voltage codes are not stamped on the plate, their are readable on the coils(2) Performance are guaranteed only using valves completed with coil(3) Tightening torque max. 6÷9 Nm (CH n. 22)(4) Other variants available on request

Tab.1 - Standard spools Tab.2 - Mounting

Tab.4 - Variants (1 - 4)

Tab.3 - 40W coils D15 voltage (1)

Code Voltage Max. winding temperature(Ambient temperature 25°C)

Rated powerW

Resistance @ 20°C (Ohm) ±10%

L 12 Vdc 135 °C 40 3.6

M 24 Vdc 135 °C 40 14.4

W (2) Without coils

ORDERING CODE

PRESSURE DROPS LIMITS OF USE

The diagram at the side shows the pressure drop curves for spools during normal usage.The fluid used is a mineral oil with a viscosity of 46 mm²/s at 40 C°; the tests have been carried out at a fluid temperature of 40 C°.

The tests have been carried out with solenoids at operating temperature and a voltage 10% less than rated voltage with a fluid temperature of 50 C°. The fluid used was a mineral oil with a viscosity of 46 mm²/s at 40 degrees C.Spool 01: in neutral position can have leaks.

1 = Spool 013 = Spool 03

®

86

Page 89: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

2

CD5

78

43

49

59

n°4 Ø 6.5

32.5

45.5

N°2 ORINGS 2-013 NBR 90Sh

181.7

38

N°2 G1/2"

N°2 Ø 31

95.5 8046

80

255.5

2325

81

.5

22

.5

98.5

Ø 3

2

81

.5

22

.5

max 66

120

81

.5

17

Ø 3

0

22

.5

max 63

117

66.5

54.3

IE/CD5001/00-2017

OVERALL DIMENSIONS

VARIANTS

Emergency P2 and P5, tightening torque max. 6÷9 Nm (CH n. 22)

“ES” Manual emergency

“P2”Rotary emergency

“CZ” Deutsch DT04-2P“R6” Deutsch DT04-2P eCoat treatment

“R5” Rotary emergency 180°

Single solenoid versions

Fittings, max. tightening torque 60 Nm

Manual emergency

®

87

Page 90: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

2

FU5

IE/FU5001/00-2017

FU

5

5

1

00

T

P70

70

49

5943

N°6 Ø 6 5.

24 5.

812

G3/4"

30

8 54

15

N°2 M6 12

OUTLET MODULE UNITS

HYDRAULIC SYMBOLS

FEATURES

Max. operating pressure 310 barMax. Flow 80 l/minHydraulic fluid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (filter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 0.95 kg

Outlet module units FU5.• Threaded ports (T) sizes G3/8”.• Maximum flow 80 l/min.• Cast iron zinc plated body.

ORDERING CODE

OVERALL DIMENSIONS

Outlet module unit

Size

Port size:5 = G3/4”

00 = No variants

Serial No.

®

88

Page 91: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

3

MODULAR

ELEMENTS

(Applicability with SIZE 6 valves, see pages 8, 58)

®

89

Page 92: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

3

53

27,6

31

19

35

70

36

~ 129

45

n. 4 Ø 5

T

A

T

B

V08000005

IE/V08000005/01-2015

V08000005

1 2 2.5 3 3.5 4

4.5

5

5.5

6

0 2 4 6 8 10 12 14 16 18 20

0

20

40

60

80

100

120

140

160

180

200

220

240

P(b

ar)

Q (l/min)

A BT T

INTERMEDIATE ELEMENT WITH FLOW REGULATOR ON A AND B LINES

FEATURES

Max. operating pressure 250 barFlow rate regulation on 6 screw turnsMax. Flow 20 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 1.3 kg

Intermediate element V08000005 with fl ow regulator on A and B lines• Intermediate mounting to combine with valves CM3F/CM3P/CM3M• One way non-compensated throttle valves adjustable by means of a grub

screw on A and B lines. • Maximum fl ow 20 l/min.• Cast iron zinc plated body.

ORDERING CODE OVERALL DIMENSIONS

FLOW REGULATION

Element with fl ow regulator on A and B lines

n° of turns unscrewing

HYDRAULIC SYMBOL

®

90

Page 93: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

3

V08000002

V08000002

IE/ V08000002/00-2017

Q (l/min)

0 4 82 6 10 12 14 16 18 20

0

5

10

15

20

P(b

ar)

1

2

AT B T

38

8

31

35

62

74

36

45

n. 4 Ø 5.2519

T

A

T

B

INTERMEDIATE ELEMENT WITH PILOT OPERATED CHECK STACKABLE VALVES

FEATURES

Max. operating pressure 250 barMinimum opening pressure 5 barMax. Flow 20 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm2/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 0.69 kg

Modular pilot operated check stackable valves V08000002 • Intermediate mounting to combine with valves CM3F/CM3M• Double A and B lines; • Cast iron zinc plated body.

ORDERING CODE OVERALL DIMENSIONS

FLOW REGULATION

Pilot operated check stackable valve

HYDRAULIC SYMBOL

1 = piloted side fl ow 2 = minimum opening pressure

®

91

Page 94: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

3

CM3F

CM

3

F

**

1

IE/ CM3F001/01-2015

G3/8"

2 x O-RING 2-012 90Sh

70

45

30,5

36

31

27

A BT T

MODULAR ELEMENTS WITH PORTS A-B

FEATURES

Max. operating pressure 250 barMax. Flow 40 l/minHydraulic fl uid DIN 51524 Mineral oilsFluid viscosity 10 ÷ 500 mm²/sFluid temperature -25°C ÷ 75°CAmbient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 0.54 kg

Modular elements CM3F with ports A-B. • Convert modular interface into threaded ports. • Maximum fl ow 40 l/min.• Threaded ports sizes G3/8”• Cast iron zinc plated body.

ORDERING CODE OVERALL DIMENSIONS

Intermediate element

Size

With ports A-B

00 = No variantV1 = Viton

Serial No.

Accessories

Tightening torque 5 Nm

Elements Code screws(x 4)

TypeUNI 5931 - 8.8

CM3F Q26074069 M5x35

CM3F +V0800005 Q26074077 M5x80

HYDRAULIC SYMBOL

®

92

Page 95: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

3

CM3P

IE/CM3P001/01/2011

CM3P*A

CM

3

**

**

1

P

*

*

CM3P*B CM3P*AB

A B A B A B

MODULAR PILOT OPERATED CHECK BANKABLE VALVES

CM3P type modular check bankable valves allow one way free fl ow by raising a conical shutter, while in the opposite direction the fl uid can return by means of a small piston piloted by the pressure in the other line.• Available on single A or B lines, and on double A and B lines (see hydraulic

symbols). • Threaded ports G3/8” or 9/16”-18UNF.• Cast iron zinc plated body.

FEATURESORDERING CODE

Max. operating pressure 350 barMinimum opening pressure spring 1 1 barMinimum opening pressure spring 5 5 barPiloting ratio 1:4Max. fl ow 40 l/minHydraulic fl uids Mineral oils DIN 51524Fluid viscosity 10 ÷ 500 mm²/sFluid temperature -20°C ÷ 75° CAmbient temperature -20°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 1.25 kg

Modular bankable valve

Size

Piloted check valve

Port sizes:1 = G3/8”2 = 9/16”-18UNF

Control on lines A / B / AB

Minimum opening pressure1 = 1 bar5 = 5 bar

00 = No variantV1 = Viton

Serial No.

HYDRAULIC SYMBOLS

Accessories

Tightening torque 5 Nm

Elements Code screws(x 4)

TypeUNI 5931 - 8.8

CM3P Q26074072 M5x50

CM3P +V0800005 Q26074252 M5x95

®

93

Page 96: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

3

Q (l/min)

P(b

ar)

0 10 205 15 25 3530 40

0

5

10

15

20

3

2

1

CM3P

IE/CM3P001/01/2011

(104)

907 7

49

42.5

G3/8"31

5

45

47 CM3P.AB...1

CM3P.A...1

CM3P.B...1

36

4 x O-RING 2025/2-010 N552 90SH

PRESSURE DROPS

1 = Piloted side flow2 = 1 bar3 = 5 bar

OVERALL DIMENSIONSMOUNTING EXAMPLE WITH CDC3 VALVE

The fluid used is a mineral based oil with a viscosity of 46 mm²/s at 40°C. The tests have been carried out at with a fluid of a 40°C.

®

94

Page 97: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

3

CM3M

IE/CM3M002/01/2011

CM3M*A

CM

3

*

**

*

M

*

C

CM3M*B CM3M*AB

**

2

A BT A BT T A BT T

MODULAR MAX. PRESSURE BANKABLE VALVES

Modular max. pressure bankable valves CM3M with direct acting pressure relief valves CMP10 • Pressure range 1 ÷ 320 bar, manual adjustment with a grub screw.• All versions can accept three types of springs with calibrated ranges as

shown in the specifi cations. For the minimum permissible setting pressure depending on the spring, see minimum pressure setting curve.

• Available single on A or B lines, and double on AB lines, see hydraulic symbols

• Cast iron zinc plated body.

FEATURESORDERING CODE

Modular bankable valve

Size

Maximum pressure valve

Port sizes:1 = G3/8”2 = 9/16”-18UNF

Adjustment on the lines: A / B / AB

Type of adjustmentGrub screw

Setting ranges at port A0 = max. 15 bar (neutral spring)1 = max. 50 bar (white spring)2 = max. 150 bar (yellow spring)3 = max. 320 bar (green spring) Setting ranges at port B (Omit if the setting is same as that at port A)0 = max.15 bar (neutral spring)1 = max. 50 bar (white spring)2 = max. 150 bar (yellow spring)3 = max. 320 bar (green spring) 00 = No variantV1 = Viton

Serial No.

HYDRAULIC SYMBOLS

Max. operating pressure 320 barSetting ranges:spring 0 spring 1 spring 2spring 3

15 bar50 bar150 bar320 bar

Max. fl ow 40 l/minHydraulic fl uids Mineral oils DIN 51524Fluid viscosity 10 ÷ 500 mm²/sFluid temperature -20°C ÷ 75° CAmbient temperature -20°C ÷ 60°CMax. contamination level (fi ltro ß25 75)

ISO 4406:1999: classe 21/19/16NAS 1638: classe 10

Weight CM3MA/BWeight CM3MAB

1.66 kg1.68 kg

Tightening torque 5 Nm

Elements Code screws(x 4)

TypeUNI 5931 - 8.8

CM3M Q26074073 M5x55

CM3M +V0800005 Q26074251 M5x100

Accessories

®

95

Page 98: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

3

CM3M

IE/CM3M002/01/2011

Q (l/min)

P(b

ar)

1

0

2

3

0 5 10 15 20 25 30 35 40

0

40

80

120

160

200

240

280

320

360

Q (l/min)

P(b

ar)

3

2

1

0

0 5 10 15 20 25 30 35 40

0

20

40

60

80

100

30.5

G3/8"

45

31

=

=

CM3M-ABC----2

CM3M-AC----2

CM3M-BC----2

7.1

54 112 54

(220)

54

22

47.5

4 x O-Ring 2-010 90Sh

Curve 0,1,2,3:setting ranges valve

OVERALL DIMENSIONSMOUNTING EXAMPLE WITH CDC3 VALVE

The fluid used is a mineral based oil with a viscosity of 46 mm²/s at 40°C. The tests have been carried out at with a fluid of a 40°C.

PRESSURE - FLOW RATE MINIMUM SETTING PRESSURE

DIAGRAMS

®

96

Page 99: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

4

ACCESSORIES

®

97

Page 100: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

4

IE/HSIF00/01/2011

HSIF

HSIF00

41

05033

HP

V41

P

P

T

LS

T

T1

T1LS

LS

P

T

CX

DH

3

127

128,5

59

49

43

39

34

46,5

39

M6-6h 12n. 4

147max

133

O-Ring 2018/2-008 90Sh

O-Ring 2037/2-012 N552 90Sh

O-Ring 2037/2-012 N552 90Sh

7028,5

M8-6H 15n.2

28,5

36.5

10.5

26.5

17.5 92

25

85

Interface between HPV41 and CDC3 / CD3 / CX3 / CXDH3 / CDH3 • HSIF interface hydraulically connects the elements of proportional valves

CX3/CXDH3 or ON/OFF valves CDC3/CD3/CDH3 with the elements of pro-portional valve HPV 41. This type of combination is highly appreciated in those cases involving great differences in fl ow between the controlled actuators.

• The HSIF module must be inserted into the proportional valve confi gura-tion between the last HPV41 working section and the fi rst CDC3/CD3/CX3/CXDH3/CDH3 working section. Up to eight elements of the HPV41 and eight elements of the CDC3/CD3/CX3/CXDH3/CDH3 can be installed. The HSIf interface replace the inlet module for CDC3/CD3/CX3/CXDH3/CDH3.

• With the HSIF interface use the FUH outlet module.• Cast iron zinc plated body.

Interface

HPV Type (HPV 41)

Identifying code

INTERFACE FOR PROPORTIONAL DIRECTIONAL VALVES HPV41

ORDERING CODE

FEATURES

Max. operating pressure 300 bar

Max. Flow 80 l/min

Fluid viscosity 10 ÷ 500 mm²/s

Fluid temperature -25° ÷ 75° C

Ambient temperature -25°C ÷ 60°CMax. contamination level (fi lter ß25 75)

ISO 4406:1999: class 21/19/16NAS 1638: class 10

Weight 3.8 kg

HYDRAULIC SYMBOL

OVERALL DIMENSIONS

cavity for csrv or hesc.please see HPV catalogue

®

98

Page 101: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

4

IE/BANK-MOUNTINGKIT/03-2017

46A B

L

FE3 / FE02 (A=30 mm)FU3 (B=15 mm) FU3* (B=20 mm) FUT3 (B=25 mm) FUS3 (B=35 mm)

L (mm) L (mm) L (mm) L (mm)

1 V89B50042 121 V89B50043 125 V89B50043 125 V89B50044 140

2 V89B50047 160 V89B50012 170 V89B50012 170 V89B50022 180

3 V89B50013 210 V89B50013 210 V89B50023 220 V89B50049 230

4 V89B50014 260 V89B50014 260 V89B50024 270 V89B50024 270

5 V89B50052 300 V89B50015 310 V89B50015 310 V89B50053 320

6 V89B50016 350 V89B50016 350 V89B50026 361 V89B50036 380

7 V89B50055 390 V89B50017 400 V89B50017 400 V89B50027 410

8 V89B50018 440 V89B50028 450 V89B50028 450 V89B50056 460

FE10S (A=35 mm)FU3 (B=15 mm) FU3* (B=20 mm) FUT3 (B=25 mm) FUS3 (B=35 mm)

L (mm) L (mm) L (mm) L (mm)

1 V89B50042 121 V89B50043 125 V89B50043 125 V89B50045 145

2 V89B50012 170 V89B50012 170 V89B50022 180 V89B50032 190

3 V89B50013 210 V89B50023 220 V89B50023 220 V89B50049 230

4 V89B50014 260 V89B50024 270 V89B50024 270 V89B50034 285

5 V89B50015 310 V89B50015 310 V89B50015 310 V89B50035 330

6 V89B50016 350 V89B50026 361 V89B50026 361 V89B50036 380

7 V89B50017 400 V89B50017 400 V89B50027 410 V89B50037 430

8 V89B50028 450 V89B50028 450 V89B50028 450 V89B50038 470

FELS / FE10 / FE10LS (A=40 mm)FU3 (B=15 mm) FU3* (B=20 mm) FUT3 (B=25 mm) FUS3 (B=35 mm)

L (mm) L (mm) L (mm) L (mm)

1 V89B50043 125 V89B50021 130 V89B50044 140 V89B50046 150

2 V89B50012 170 V89B50022 180 V89B50022 180 V89B50032 190

3 V89B50023 220 V89B50023 220 V89B50049 230 V89B50033 240

4 V89B50024 270 V89B50024 270 V89B50024 270 V89B50034 285

5 V89B50015 310 V89B50015 310 V89B50053 320 V89B50035 330

6 V89B50026 361 V89B50026 361 V89B50036 380 V89B50036 380

7 V89B50017 400 V89B50027 410 V89B50027 410 V89B50037 430

8 V89B50028 450 V89B50028 450 V89B50056 460 V89B50038 470

FE02Q / FE10P / FE10PS (A=57 mm) - FE10X (A=59 mm)FU3 (B=15 mm) FU3* (B=20 mm) FUT3 (B=25 mm) FUS3 (B=35 mm)

L (mm) L (mm) L (mm) L (mm)

1 V89B50044 140 V89B50045 145 V89B50046 150 V89B50047 160

2 V89B50032 190 V89B50048 199 V89B50048 199 V89B50013 210

3 V89B50033 240 V89B50033 240 V89B50050 250 V89B50014 260

4 V89B50034 285 V89B50034 285 V89B50051 296 V89B50052 300

5 V89B50035 330 V89B50035 330 V89B50054 340 V89B50016 350

6 V89B50036 380 V89B50036 380 V89B50055 390 V89B50017 400

7 V89B50037 430 V89B50037 430 V89B50037 430 V89B50018 440

8 V89B50038 470 V89B50038 470 V89B50057 480 V89B50058 490

Mounting kit

Kit composed by No. 4 rods and No. 8 stud nuts

Nuts tightening torque: 10NmFor more combinations contact our customer service.

Intlet module Outlet moduleElements

Mounting kitCode

Intlet module

Code

Elem

ents

Outlet moduleCode Code Code

Intlet module

Code

Elem

ents

Outlet moduleCode Code Code

Intlet module

Code

Elem

ents

Outlet moduleCode Code Code

Intlet module

Code

Elem

ents

Outlet moduleCode Code Code

SIZE 6ON/OFF and proportional valves

®

99

Page 102: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

4

IE/BANK-MOUNTINGKIT/03-2017

46 30

L

FEH30PQ / FEH30LSFEH30PQ / FEH35PQ/ HSIF

FUH (B=30 mm)

L (mm)

1 V89B50001 100

2 V89B50002 145

3 V89B50003 190

4 V89B50004 240

5 V89B50005 285

6 V89B50006 330

7 V89B50007 380

8 V89B50008 430

FE5 / FE305FU5 (B=30 mm)

L (mm)

1 V89B50002 100

2 V89B50003 145

3 V89B50004 190

4 V89B50005 240

5 V89B50006 285

6 V89B50008 330

46

L

Mounting kit

Kit composed by No. 4 rods and No. 4 stud nuts

Nuts tightening torque: 10Nm

For more combinations contact our customer service.

Intlet module

Outlet module

Elements

Mounting kitCode

* only valves with LS line: CDC3/CD3 body “L-M” ; CX3 body “L”

Intlet module

Code

Elem

ents

*

Outlet module

SIZE 6Pre and post compensated valves

Kit composed by No. 4 rods and No. 4 stud nuts

Nuts tightening torque: 10Nm

For more combinations contact our customer service.

Intlet module Outlet moduleElements

Mounting kitCode

Intlet module

Code

Elem

ents

*

Outlet module

SIZE 10ON/OFF valves

®

100

Page 103: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

425

25

3

3

70

20

49

59

6,5

19 32 19

7

9

19

IE/BANK-FIXINGFEET/03-2017

Fixing feet

* Fixing feet can not be used with HSIF interface module unit.** If the kit is not required, the valve can be fixed by the fixing holes on the bottom faces of the inlet

and outlet modules (see drawing on page 57 and 80).

Intel module FE10, outlet module FU, mounting on BOTTOM position (standard mounting)

Intel module FE10, outlet module FU, mounting on TOP position (to be specify)

Intel module FEH30PQ, outlet module FUH, mounting on BOTTOM position (standard mounting)

Intel module FEH30PQ, outlet module FUH, mounting on TOP position (to be specify)

Code Type

V89980000SIZE 6 - ON/OFF and proportional valvesKit supplied with the valves, composed by:- No. 2 feet

V89B60000 (*)

Screw tightening torque: 10Nm

SIZE 6 - Pre and post compensated valvesKit supplied on request (**) composed by:- No. 2 feet- No. 4 screws- No. 4 washers

V89B60001 (*)

Screw tightening torque: 10Nm

SIZE 10 - ON/OFF valvesKit supplied on request (**) composed by:- No. 2 feet- No. 2 screws- No. 2 washers

Feet mounting example

Intel module FE305, outlet module FU5, mounting on BOTTOM position (standard mounting)

®

101

Page 104: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

4

Ø d

Ø 7.4

xx

Ø 8.6

Ø d

xx

Ø 7.9

Ø 8.6

IE/BANK-DIAPHRAGMS/00-2016

BABABA

T1

P1P

T

A BM

65 bar

110 bar

170

Bar

Ø 1

A B 65 bar140 bar

Calibrated diaphragmsFOR VALVES CD3 / CDC3 / CDCM3 FOR VALVES CDH3 / CXDH3 / CFS3

Ø d (mm) Code Stamping

xxCLOSED M52050043/3 /

0.5 M52050043/2 05

1.0 M52050043 10

2.0 M52050043/10 20

2.2 M52050043/1 22

3.0 M52050043/30 30

Ø d (mm) Code Stamping

xxCLOSED M52050023/4 /

0.3 M52050023/21 03

0.4 M52050023/22 04

0.5 M52050023/1 05

0.6 M52050023/6 06

0.7 M52050023/8 07

0.8 M52050023 08

0.9 M52050023/17 09

1.0 M52050023/2 10

1.1 M52050023/20 11

1.2 M52050023/3 12

1.3 M52050023/19 13

1.4 M52050023/16 14

1.5 M52050023/7 15

1.6 M52050023/15 16

1.8 M52050023/11 18

1.9 M52050023/14 19

2.0 M52050023/10 20

2.2 M52050023/9 22

2.5 M52050023/5 25

2.7 M52050023/13 27

3.0 M52050023/18 30

3.5 M52050023/12 35

HYDRAULIC CIRCUIT EXAMPLE WITH CALIBRATED DIAPHRAGM ON “P” LINE

®

102

Page 105: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

4Ø 6÷8 mm (PG09)

Ø 8÷10 mm (PG11)

IP65

Ø 4÷7 mm19

IP67

M3

4.5

42

28.5 29.5

Ø 6÷8 mm (PG09)

Ø 8÷10 mm (PG11)

34.54.5

M3

42

29.5

Ø 6÷8 mm (PG09)

4.5

M3

32

62

29.5

Ø 4÷7 mm

IE/BANK-CONNECTORS/03-2015

81.5

Ø 2 ÷ 3 mm

20

23

.5

1

2

1

2

1

2

1

2

ConnectorsCONNECTORS FOR CONTROL VALVES IN ACCORDANCE WITH DIN 43650 / ISO 4400

Connector Protection level Type Cable gland Code

Standard IP65

Black color PG09 V86 05 0002Grey color PG09 V86 05 0004Black color PG11 V86 05 0006Grey color PG11 V86 05 0008

Lens cover with pilot light (1) IP65

12 VAC/VDC PG09 V86 10 001824 VAC/VDC PG09 V86 10 0012115 VAC/VDC PG09 V86 10 0020230 VAC/VDC PG09 V86 10 0022

Connector Protection level Type Cable gland Code

With rectifier (1)Inlet voltage 12÷230 VACOutlet voltage 9÷205 VDC

IP65Black color PG09 V86 20 0002

Grey color PG09 V86 20 0004

Lens cover with pilot light and rectifier (1)Inlet voltage 12÷230 VACOutlet voltage 9÷205 VDC

IP65

12 VAC PG09 V86 25 001824 VAC PG09 V86 25 001948 VAC PG09 V86 25 0020115 VAC PG09 V86 25 0021230 VAC PG09 V86 25 0022

Connector Protection level Type Cable gland Code

With protection level IP67 IP67Black color — V86 28 0001Grey color — V86 28 0002

Seal

Cable gland

Seal

Seal

Cable gland

AMP JUNIOR CONNECTORS

Description IP65 IP67

AC rated voltageDC rated voltage

Max. 250 VMax. 300 V

Max. 250 VMax. 300 V

Pin conctat nominal currentPin conctat max. current

10A 16A

10A 16A

Max. section cable 1.5 mm² 1.5 mm²

Cable gland PG09 - M16x1,5Cable gland PG11 - G 1/2” - M20x1,5

Ø cable 6 ÷ 8 mmØ cable 8 ÷ 10 mm

Ø cable 4 ÷ 7 mm—

Protection levelInsulation classOperating temperature

IP65 EN60529VDE 0110-1/89-40°C ÷ 90 C°

IP67 EN60529VDE 0110-1/89-20°C ÷ 80 C°

The degrees of protection indicate is guaranteed only if the connectors were properly mounted with his original seals.

Electrical features of connectors

Connector Type Cable section Pin conctatmax current Code

AMP Junior connector Timer 2 conctat Black color 0.5 ÷ 1.5 mm2 10A RKRC0808000

Screw tightening torque: 0.60 Nm

Screw tightening torque: 0.60 Nm

(1) do not use for proportional versions

(1) do not use for proportional versions

Standard Bipolar led Rectifier andVDR protection

Bipolar led, rectifier andVDR protection

Electrical circuits

®

103

Page 106: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

4

17

21.5

20.5

Ø13.25

30 38.6

42

12

28ISO 4400

(DIN 43650)

28

30 39

20.5

36.5

40.5

23.828

41

61.5

36 38.5

60

.8

47

.8

23

.5

19.1

IE/BANK-COILS/05-2017

Coils

(1) Ambient temperature 25 °C - (2) Ambient temperature 20 °C(3) The european low voltage directive is applied to electronical equipments used at a nominal voltages

between 50 and 1000 VAC or 75 and 1500 VDC. In conformity with the low directive each part of the manifold or the subplate on which the valve is mounted should be connected to a protective earth with a resistence less than 0.1 ohms.

STANDARD Hirschmann ISO 4400 DIN43650

DEUTSCH and bidirectional integrated diode (CX variant)

(1) Ambient temperature 25 °C - (2) Ambient temperature 20 °C

Type of protection IP 65Number of cycle 18000/hSupply tolerance ±10%Ambient -30°C ÷ 60°C

Coil Max windingtemperature (1)

Ratedpower

Resistance±7% (2)

SparecodeCode Voltage

L 12 VDC 135 °C 18 W 7.7 M14000001M 24 VDC 135 °C 18 W 31 M14000002N 48 VDC 135 °C 18 W 116 M140000032 21.6 VDC 135 °C 18 W 27 M14000009Z 102 VDC (3) 120 °C 18 W 578 M14000006X 205 VDC (3) 120 °C 18 W 2627 M14000007

Coil Max windingtemperature (1)

Ratedpower

Resistance±7% (2)

SparecodeCode Voltage

L 12 VDC 135 °C 18 W 7.7 M14760001M 24 VDC 135 °C 18 W 31 M14760002

Duty cycle 100% EDInsulation class wire FWeight 0.141 kg

18W COILS

22W COILS

AMP Junior (AJ variant)

(1) Ambient temperature 25 °C - (2) Ambient temperature 20 °C

Type of protection IP 65Number of cycle 18000/hSupply tolerance ±10%Ambient temperature -30°C ÷ 60°C

Duty cycle 100% EDInsulation class wire HWeight 0.2 kg

Coil Max windingtemperature (1)

Ratedpower

Resistance±7% (2)

SparecodeCode Voltage

L 12 VDC 135 °C 22 W 6.3 M14730001M 24 VDC 135 °C 22 W 25.6 M14730002

®

104

Page 107: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

4

18

12

46

Ø14.1 min

36 39

2828

ISO 4400

(DIN 43650)

18

46

59

17

36 39

19.9

18

65.9

36 38.5

18

16.5

46

5

F I

= 2

50

= 1

30

36 39

IE/BANK-COILS/05-2017

Coils27W COILS - A09

(1) Ambient temperature 25 °C - (2) Ambient temperature 20 °C(3) The european low voltage directive is applied to electronical equipments used at a nominal voltages

between 50 and 1000 VAC or 75 and 1500 VDC. In conformity with the low directive each part of the manifold or the subplate on which the valve is mounted should be connected to a protective earth with a resistence less than 0.1 ohms.

STANDARD Hirschmann ISO 4400 DIN43650 (H connection)

WIRES and integrated bidirectional DIODE (F/I connection - FL/LD variant)

AMP Junior (A connection - AJ variant)

(1) Ambient temperature 25 °C - (2) Ambient temperature 20 °C

(1) Ambient temperature 25 °C - (2) Ambient temperature 20 °C

Type of protection IP 65Number of cycle 18000/hSupply tolerance ±10%Ambient temperature -30°C ÷ 60°C

Duty cycle 100% EDInsulation class wire HWeight 0.215 kg

DEUTSCH + bidirectional DIODE - DT04-2P (D connection - CX variant)

(1) Ambient temperature 25 °C - (2) Ambient temperature 20 °C

Coil Max windingtemperature (1)

Ratedpower

Resistance±7% (2)

SparecodeCode Voltage

L 12 VDC 123 °C 27 W 5.3 M14310001M 24 VDC 123 °C 27 W 21.3 M14310002N 48 VDC 123 °C 27 W 85.3 M14310003Z 102 VDC (3) 123 °C 27 W 392 M14310008P 110 VDC (3) 123 °C 27 W 448 M14310005X 205 VDC (3) 123 °C 27 W 1577 M14310009

Coil Wires(mm)

Max windingtemperature (1)

Ratedpower

Resistance±7% (2)

SparecodeCode Voltage

L 12 VDC F = 250 123 °C 27 W 5.3 M14070011M 24 VDC F = 250 123 °C 27 W 21.3 M14070012L 12 VDC I = 130 123 °C 27 W 5.3 M14330001M 24 VDC I = 130 123 °C 27 W 21.3 M14330002

Coil Max windingtemperature (1)

Ratedpower

Resistance±7% (2)

SparecodeCode Voltage

L 12 VDC 123 °C 27 W 5.3 M14320001M 24 VDC 123 °C 27 W 21.3 M14320002

Coil Max windingtemperature (1)

Ratedpower

Resistance±7% (2)

SparecodeCode Voltage

L 12 VDC 123 °C 27 W 5.3 M14340001M 24 VDC 123 °C 27 W 21.3 M14340002

®

105

Page 108: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

4

33

*** VDC

100% ED

30.6

54Ø 45

1.1

Ø 2

3

Ø 2

7

31.2

33

*** VDC

100% ED

30.6

54Ø 45

1.1

Ø 2

3

Ø 2

7

31.2

IE/BANK-COILS/05-2017

33

*** VDC

100% ED

30.6

54Ø 45

1.1

Ø 2

3

Ø 2

7

31.2

12

33

*** VDC

100% ED

30.6

54Ø 45

1.1

Ø 2

3

Ø 2

7

31.2

12

30 W COILS - D15

(1) Ambient temperature 25 °C (2) Ambient temperature 20 °C(3) The european low voltage directive is applied to electronical equipments used at a nominal voltages

between 50 and 1000 VAC or 75 and 1500 VDC. In conformity with the low directive each part of the manifold or the subplate on which the valve is mounted should be connected to a protective earth with a resistence less than 0.1 ohms.

(1) Ambient temperature 25 °C (2) Ambient temperature 20 °C

Type of protection IP 66Number of cycle 18000/hSupply tolerance ±10%Ambient temperature -25°C ÷ 60°C

Duty cycle 100% EDInsulation class wire HWeight 0.354 kg

(1) Ambient temperature 25 °C (2) Ambient temperature 20 °C

Coils

STANDARD Hirschmann ISO 4400 DIN43650Coil Max winding

temperature (1)Ratedpower

Resistance±7% (2)

SparecodeCode Voltage

L 12 VDC 110 °C 30 W 4.8 M14450002M 24 VDC 110 °C 30 W 18.8 M14450004V 28 VDC 110 °C 30 W 25.6 M14450005N 48 VDC 110 °C 30 W 75.2 M14450006Z 102 VDC (3) 110 °C 30 W 340 M14450018P 110 VDC (3) 110 °C 30 W 387 M14450008X 205 VDC (3) 110 °C 30 W 1378 M14450019

AMP Junior (AJ variant)Coil Max winding

temperature (1)Ratedpower

Resistance±7% (2)

SparecodeCode Voltage

L 12 VDC 110 °C 30 W 4.8 M14460002M 24 VDC 110 °C 30 W 18.8 M14460004

AMP Junior + Bidirectional DIODE (AD variant)Coil Max winding

temperature (1)Ratedpower

Resistance±7% (2)

SparecodeCode Voltage

L 12 VDC 110 °C 30 W 4.8 M14470002M 24 VDC 110 °C 30 W 18.8 M14470004

(1) Sealed coil winding with steel out housing with eCoat protection. Has succesfully overcome more than 700 hours of salt spray test before red rust (test according to UNI EN ISO 9227 and test evalua-tion according to UNI EN ISO 10289).

(2) Ambient temperature 25 °C (3) Ambient temperature 20 °C(4) The european low voltage directive is applied to electronical equipments used at a nominal voltages

between 50 and 1000 VAC or 75 and 1500 VDC. In conformity with the low directive each part of the manifold or the subplate on which the valve is mounted should be connected to a protective earth with a resistence less than 0.1 ohms.

Hirschmann ISO 4400 DIN43650 eCoat (1) surface treatment (RS variant) Coil Max winding

temperature (2)Ratedpower

Resistance±7% (3)

SparecodeCode Voltage

L 12 VDC 110 °C 30 W 4.8 M14820001M 24 VDC 110 °C 30 W 18.8 M14820002V 28 VDC 110 °C 30 W 25.6 M14820005P 110 VDC (4) 110 °C 30 W 387 M14820008

®

106

Page 109: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

4

33

*** VDC

100% ED

30.6

54Ø 45

1.1

Ø 2

3

Ø 2

7

31.2

33

*** VDC

100% ED

30.6

54Ø 45

1.1

Ø 2

3

Ø 2

7

31.2

IE/BANK-COILS/05-2017

45.6

1.1

57.9

Ø 2

3

45.6

Ø 2

7

56.6

33.8

12

33

*** VDC

100% ED

30.6

54Ø 45

1.1

Ø 2

3

Ø 2

7

31.2

IP 69K

33

*** VDC

100% ED

30.6

54Ø 45

1.1

Ø 2

3

Ø 2

7

31.2

(1) Ambient temperature 25 °C (2) Ambient temperature 20 °C

WIRES 175 mm (SL variant)Coil Max winding

temperature (1)Ratedpower

Resistance±7% (2)

SparecodeCode Voltage

L 12 VDC 110 °C 30 W 4.8 M14480002M 24 VDC 110 °C 30 W 18.8 M14480004

Coils

(1) Ambient temperature 25 °C (2) Ambient temperature 20 °C

(1) Ambient temperature 25 °C (2) Ambient temperature 20 °C(3) The european low voltage directive is applied to electronical equipments used at a nominal voltages

between 50 and 1000 VAC or 75 and 1500 VDC. In conformity with the low directive each part of the manifold or the subplate on which the valve is mounted should be connected to a protective earth with a resistence less than 0.1 ohms.

DEUTSCH DT04-2P (CZ variant)

Hirschmann ISO 4400 DIN43650 PLASTIC body (RS variant)Coil Max winding

temperature (1)Ratedpower

Resistance±7% (2)

SparecodeCode Voltage

L 12 VDC 110 °C 30 W 4.8 M14630002M 24 VDC 110 °C 30 W 18.8 M14630004V 28 VDC 110 °C 30 W 25.6 M14630005P 110 VDC (4) 110 °C 30 W 387 M14630008

Coil Max windingtemperature (1)

Ratedpower

Resistance±7% (2)

SparecodeCode Voltage

L 12 VDC 110 °C 30 W 4.8 M14490002M 24 VDC 110 °C 30 W 18.8 M14490004

Until end of stock

(1) Sealed coil winding with steel out housing with eCoat protection. Has succesfully overcome more than 700 hours of salt spray test before red rust (test according to UNI EN ISO 9227 and test evalua-tion according to UNI EN ISO 10289).

(2) Ambient temperature 25 °C (3) Ambient temperature 20 °C

DEUTSCH DT04-2P eCoat (1) surface treatment (R6 variant)Coil Max winding

temperature (2)Ratedpower

Resistance±7% (3)

SparecodeCode Voltage

L 12 VDC 110 °C 30 W 4.8 M14830001M 24 VDC 110 °C 30 W 18.8 M14830002

(1) Ambient temperature 25 °C (2) Ambient temperature 20 °C

DEUTSCH DT04-2P + Bidirectional DIODE (CX variant)Coil Max winding

temperature (1)Ratedpower

Resistance±7% (2)

SparecodeCode Voltage

L 12 VDC 110 °C 30 W 4.8 M14370002M 24 VDC 110 °C 30 W 18.8 M14370004

®

107

Page 110: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

4

IE/BANK-COILS/05-2017

33

*** VDC

100% ED

30.6

54Ø 45

1.1

Ø 2

3

Ø 2

7

31.2

12

33

*** VDC

100% ED

30.6

54Ø 45

1.1

Ø 2

3

Ø 2

7

31.2

40 W COILS - D15

(1) Ambient temperature 25 °C

Type of protection IP 66Number of cycle 18000/hSupply tolerance ±10%Ambient temperature -54°C ÷ 60°C

Duty cycle 100% EDInsulation class wire HWeight 0.354 kg

Coils

STANDARD Hirschmann ISO 4400 DIN43650Coil Max winding

temperature (1)Ratedpower

Resistance±7% (2)

SparecodeCode Voltage

L 12 VDC 135 °C 40 W 3.6 M14600001M 24 VDC 135 °C 40 W 14.4 M14600002

(1) Ambient temperature 25 °C

DEUTSCH DT04-2P (CZ variant)Coil Max winding

temperature (1)Ratedpower

Resistance±7% (2)

SparecodeCode Voltage

L 12 VDC 135 °C 40 W 3.6 M14610001M 24 VDC 135 °C 40 W 14.4 M14610002

®

108

Page 111: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

4

33

*** VDC

100% ED

30.6

54Ø 45

1.1

Ø 2

3

Ø 2

7

31.2

33

*** VDC

100% ED

30.6

54Ø 45

1.1

Ø 2

3

Ø 2

7

31.2

IE/BANK-COILS/05-2017

33

*** VDC

100% ED

30.6

54Ø 45

1.1

Ø 2

3

Ø 2

7

31.2

12

D15P COILS - (FOR PROPORTIONAL VALVES)

Type of protection IP 66Number of cycle 18000/hSupply tolerance ±10%Ambient temperature -30°C ÷ 60°C

Duty cycle 100% EDInsulation class wire HWeight 0.354 kg

STANDARD Hirschmann ISO 4400 DIN43650Coil Max winding

temperature (1)Current Resistance

±7% (2)SparecodeCode Voltage

E 9 VDC 125 °C 2.35 A 2.25 M14230101F 12 VDC 125 °C 1.76 A 4 M14230102G 24 VDC 125 °C 0.88 A 16 M14230103

(1) Ambient temperature 25 °C - (2) Ambient temperature 20 °C

AMP Junior (AJ variant)

DEUTSCH DT04-2P (CZ variant)

Coil Max windingtemperature (1)

Current Resistance±7% (2)

SparecodeCode Voltage

E 9 VDC 125 °C 2.35 A 2.25 M14770001F 12 VDC 125 °C 1.76 A 4 M14770002G 24 VDC 125 °C 0.88 A 16 M14770003

(1) Ambient temperature 25 °C - (2) Ambient temperature 20 °C

Coil Max windingtemperature (1)

Current Resistance±7% (2)

SparecodeCode Voltage

E 9 VDC 125 °C 2.35 A 2.25 M14590001F 12 VDC 125 °C 1.76 A 4 M14590002G 24 VDC 125 °C 0.88 A 16 M14590004

(1) Ambient temperature 25 °C - (2) Ambient temperature 20 °C

Coils®

109

Page 112: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

4

®

110

Page 113: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

5

HOW TO ORDER

®

111

Page 114: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

5

IE/BANK-ORDER/02-2017

P

T

A AA AB BB B

T

P

X

GLSLSP1

P

T

LS LS LS

B B BA A A

P

LS

T

How to order

EXAMPLE WITH COMPENSATED VALVES - SIZE 6

EXAMPLE WITH NOT COMPENSATED VALVES - SIZE 6

FE1031C3002 - CXQ3CTIDFS12 - 4 x CDC3AE03CLS12 - FU31002 - V89B50025 - *

• Inlet module unit with pressure relief valve

• Size 3• Port G3/8”• Adjustment pressure

with grub screw• Setting range: 320 bar• No variant• Serial No. 2

• Open loop proportional compensated flow regulator

• Size 3• 3 way compensation

with secondary line• Flow rates 25 l/min• With decompression• Coil 1.76A (12 VDC)• No variant• Serial No. 2

• No. 4 directional control bankable valves

• Size 3• Parallel body ports G3/8”• Electrical operator• Spool 03 • Mounting C double solenoid• Coil 12 VDC • No variant• Serial No. 2

• Outlet module unit• Size 3• Port size T G3/8”• No variant• Serial No. 2

• Mounting kit for 5 bankable valves and inlet module unit FE10

* It is not need to specify the fixing kit, standard supplied

No. 8 connectors black 8 x V86050002

FEH30PQ33C3MS11 - CXDH3CA03N48GS11 - 2 x CDH3AE03C104MS11 - FUH35001 - V89B50003 - V89B60000

• Open center inlet module for fixed displacement pumps

• Electrical venting valve• Pressure compensator

element• Ports G1/2”• Adjustment pressure

with grub screw• Setting range: >150 bar• Voltage venting valve 24

VDC• No variant• Serial No. 1

• Proportional compensated valve

• Size 3• Double solenoid• Parallel body ports G3/8” • Spool 03 • Symmetrical flow path

control• Flow rating 35 l/min• Differential pressure 8

bar• Coil 24 VDC (0.88A)• No variant• Serial No. 1

• No. 2 ON/OFF compensated valve

• Size 3• Parallel body ports G3/8” • Electrical operator • Spool 03• Double solenoid• Holed washer on port A/B

1.3 l/min• Differential pressure 4 bar• Coil 24 VDC• No variant• Serial No. 1

• Outlet module unit• Size 3• Port size T G3/4”• No variant• Serial No. 1

• Mounting kit for 3 bankable valves and inlet module unit FEH30PQ

• Fixing feet kit for inlet module FEH30PQ and outlet module FUH

N. 6 connectors blackN. 1 connector grey

6 x V86050002 1 x V86050004

®

112

Page 115: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

5

IE/BANK-ORDER/02-2017

LS LS

B BA A

P

LS

T

X

LS

LS

T

P

A AB B

A A

B B

How to orderEXAMPLE WITH COMPENSATED AND NOT COMPENSATED VALVES - SIZE 6

FEH30LS33C2001 - 2 x CXDH3CA03N34GS11 - 2 x CD3LE03CMS12 - FUH35001 - V89B50004 - V89B60000

• Closed center inlet module for variable displacement load sensing pumps

• LS signal• Size 3• Ports G1/2”• Adjustment pressure

with grub screw• Setting range: 140 bar• No variant• Serial No. 1

• No. 2 proportional compensated valves

• Size 3• Double solenoid• Parallel body ports G3/8” • Spool 03 • Symmetrical flow path

control• Flow rating 18 l/min• Differential pressure 4 bar• Coil 0.88A (24 VDC)• No variant• Serial No. 1

• N. 2 directional control valves

• Size 3• Parallel body ports G3/8”

LS version• Electrical operator • Spool 03 mounting C• Double solenoid• Coil 24 VDC• No variant• Serial No. 2

• Outlet module unit• Size 3• Port size T G3/4”• No variant• Serial No. 1

• Mounting kit for 4 bankable valves and inlet module unit FEH30LS

• Fixing feet kit for inlet module FEH30LS and outlet module FUH

N. 4 connectors blackN. 4 connector grey

4 x V86050002 4 x V86050004

®

113

Page 116: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

6

IE/BANK-ORDER/02-2017

P

T T1

M A B A B A B A BA B

P

T T1

M A B A B A B A B

How to order

EXAMPLE WITH DIRECTIONAL CONTROL VALVES - SIZE 10 AND SIZE 6

FE3053C2001 - 2 x CD5N03CLS10 - 2 x CD3AE03CLS12 - 1 x CDC3AE03CLS12 - FU53001 - V89B60001

• Inlet module unit with pressure relief valve

• Size 5• Port G1/2”• Adjustment pressure

with grub screw• Setting range: 140 bar• No variant• Serial No. 1

• No. 2 directional control bankable valves

• Size 5• Parallel body ports G1/2”• Electrical operator• Spool 03 • Mounting C double

solenoid• Coil 12 VDC • No variant• Serial No. 1

• No. 2 directional control bankable valves

• Size 3• Parallel body ports G3/8”• Electrical operator• Spool 03 • Mounting C double

solenoid• Coil 12 VDC • No variant• Serial No. 2

• No. 1 directional control bankable valves

• Size 3• Parallel body ports G3/8”• Electrical operator• Spool 03 • Mounting C double

solenoid• Coil 12 VDC • No variant• Serial No. 2

• Otulet module unit• Size 5• Port size T G3/4”• No variant• Serial No. 1

• Fixing feet kit for inlet module FE305 and outlet module FU5

No. 10 connectors black 10 x V86050002

EXAMPLE WITH DIRECTIONAL CONTROL VALVES - SIZE 10

FE3053C3001 - 4 x CD5N03CLS10 - FU53001 - *

• Inlet module unit with pressure relief valve

• Size 5• Port G1/2”• Adjustment pressure with grub

screw• Setting range: 350 bar• No variant• Serial No. 1

• No. 4 directional control bankable valves

• Size 5• Parallel body ports G1/2”• Electrical operator• Spool 03 • Mounting C double solenoid• Coil 12 VDC • No variant• Serial No. 1

• Outlet module unit• Size 5• Port size T G3/4”• No variant• Serial No. 1

* Without feet kit, mounting on bottom position on inlet and outlet module

No. 8 connectors black 8 x V86050002

Maximum working pressure is defined by the lower pressure of the used valves.

®

114

Page 117: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

6

IE/BANK-ELECT-C/00-2017

Electromagnetic compatibilityELECTROMAGNETIC COMPATIBILITY “EMC” (2014/30 EC)

The PRODUCTS NOT CONTAINING ELECTRONIC BOARDS INSIDE for the actuation of the hydraulic control (as a pure example our CD3-CDC3-CXDH3, modules MHPF - MHOF) are defined “passive” from the electrical point of view, as driven by an external power/command unit. These products therefore don’t fall directly within the field of application of the aforementioned directive and therefore are not subject to the relevant certification and CE marking by Dana Brevini S.p.a.

It will be instead the external power/command unit, chosen by the Customer according to his needs and not included in the hydraulic system supplied by Dana Brevini S.p.a., who must be certified according with the directive and depending on the environment where it will be used (industrial, mobile, home).

®

115

Page 118: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

Note®

116

Page 119: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso
Page 120: Catalogue - Valves empilables · 2018. 4. 12. · i min. max. iso vg 10 10 9.00 11.0 iso vg 15 15 13.5 16.5 iso vg 22 22 19.8 24.2 iso vg 32 32 28.8 35.2 iso vg 46 46 41.4 50.6 iso

Dana Brevini S.p.A.Via Luciano Brevini 1/a42124 Reggio EmiliaTel. +39 0522 270711Fax +39 0522 270660www.dana.com/breviniinfo@brevinifl uidpower.com

®

Code DOC00046 - Rev. 09


Recommended