elM TRAHTER,lI"lC.. S50289

George Fischer has expanded itsfamily of manual diaphragmvalves with the Type 314 inpolypropylene and PVDF. Alsoavailable in PVC the 314's com­pact size makes it extremely effi­cient for the construction ofindus­trial piping systems. The 314 isideally suited for flow control,slurries, and abrasive media, aswell as vacuum applications. Itfeatures a space-saving, compactdesign achieved by casting thelower body with connectionthreads in one piece. This processeliminates additional welds whileminimizing face-to-face dimen­sions. The 314 is available in sizesV2 to 2 in. with EPDM or PTFE<EPDM-backed) diaphragms.Other features include an op­tional locking handwheel, posi­tion indicator, and threadedmounting inserts. The true uniondiaphragm valve is also availablepneumatically actuated.Circle 414 on the re.der ..rvlce cerd

............ VALvaGeorge Fischer Inc., Tustin, Calif.

PLATECOIL®prime surf.lCehear exchangers

trantetISO 9001 CERTIFIED

Tranter. inc.•Texas Dtvislon. P.O. Box 2289. Wichita Falls. Texas 76307(940J 723·7125. Fax (940) 723·5131

http://www.tranter.com

.6 Heat transfer solutions for all kinds of applications

.6 Can be fabricated inro platens, vessels, banks, shrouds, walls,baHles...any size or shape ro suit your process needs

.6 Accurate, consistent heating or cooling over the entire surface area

.6 Heating or cooling; liquids, steam, refrigerants and pressurized gases

The performance possibilities are unlimited! Contact Tranter todayfor an illustrated brochure covering the range of PLATECOILapplications.

Temperature control whenand where you want it

Circle 061 on reader information card

COLO••ITDPaul N. Gardner Co. Inc., PompanoBeach, Fla.

The Lico 300 Colorimeter is a self­contained lab that meets ASTM D156 and 1500, DIN 5033, and EN1557. The colorimeter featuresautomatic cuvette detection andautomatic measurement, cleardisplay, user profiles with pass­word protection, program module,documentation conforming toGLP, and integrated test mediacontrol. ..

Circle 413 on the re.der service cerd

CATALY1'IC OXIDA1'IOII SVa­Glenro Inc.• Paterson. N.J.

Glenro's 1800 scfm oxidizer sys­tem destroys a 4lblhr load of hex-

58 Mml Finishing

Page 2: Catalytic oxidation system

PUMPSMagnatex Pumps Inc., Houston

ensures ease ofoperation and con­sistent Dubpernell results.Circle 417 on the reader service card

Circle 007 on reader information card

Getting value out of your cleaning solvent.

NEW FROM BASF:

MICROPOROUS NICKIL PIIOCUSMacDermid Inc.. Waterhury', COIl11.

NiMac Hypore XL, the company'snew microporous nickel process,is essential for those electroplat­ers who are required to meet spec­ifications. NiMac Hypore XL, inconjunction with MacDermid'scopper, semibright and brightnickel, and chrome processes, pro­vides high pore count giving supe­rior corrosion resistance thatmeets or exceeds all current OEMspecifications. The technology em­ployed in this low-solids process

ane, MEK, ethyl acetate, and tol­uene. The oxidizer systemmeasures 20 ft x 5 ft x 9 ft, in­cluding the heat exchanger, duct­work, supply blower, and steelskid. The system, custom-de­signed and manufactured for acustomer's specific process re­quirements, is built predomi­nantly of heavy-gauge 304 stain­less steel and is extensivelyinsulated.Circle 415 on the reader service card

PARTS WASHERGUYSOII Corp. of U.S.A., Sarato~aSprill~s. N. Y.

The Guyson Orbit 1000 has a 42­in. diameter basket, a maximumwork height of 18 in., and holdsup to 1,000 Ib of components. Thebasket, tank, and hood of the sys­tem are fabricated in high-qualitystainless steel to resist corrosion.Complete insulation of the tankand hood helps maintain opti­mum operating temperature andreduces energy requirements. The"V-spray" pattern jets providemaximum impingement and totalcoverage of components. A perfo­rated chip basket keeps chips, de­bris, and small parts from beingrecirculated into the wash tank. Afresh or recirculated rinsing stagecan be provided to flush detergentresidues from parts.Circle 416 on the reader .ervice card