PDuke Energy. D.M. JAMIL Vice President Catawba Nuclear Station 4800 Concord Rd. / CN01 VP York, SC 29745-9635 803 831 4251 803 831 3221 fax July 18, 2006 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555 Subject: Duke Power Company LLC d/b/a Duke Energy Carolinas, LLC (Duke) Catawba Nuclear Station, Unit 2 Docket Number 50-414 Steam Generator Outage Summary Inservice Inspection Report for End of Cycle 14 Refueling Outage Please find attached the subject report which provides the results of the steam generator tube inservice inspection effort associated with the subject outage. There are no regulatory commitments contained in this letter or its attachment. If you have any questions concerning this material, please call L.J. Rudy at (803) 831-3084. Very truly yours, D.M. Jamil LJR/s Attachment A oct:7 www. duke-energy. corn
Transcript
Page 1: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

PDukeEnergy.

D.M. JAMILVice President

Catawba Nuclear Station4800 Concord Rd. / CN01 VPYork, SC 29745-9635

803 831 4251

803 831 3221 fax

July 18, 2006

U.S. Nuclear Regulatory CommissionAttention: Document Control DeskWashington, D.C. 20555

Subject: Duke Power Company LLC d/b/a Duke EnergyCarolinas, LLC (Duke)Catawba Nuclear Station, Unit 2Docket Number 50-414Steam Generator Outage Summary InserviceInspection Report for End of Cycle 14Refueling Outage

Please find attached the subject report which provides theresults of the steam generator tube inservice inspectioneffort associated with the subject outage.

There are no regulatory commitments contained in this letteror its attachment.

If you have any questions concerning this material, pleasecall L.J. Rudy at (803) 831-3084.

Very truly yours,

D.M. Jamil

LJR/s

Attachment

A oct:7

www. duke-energy. corn

Page 2: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Document Control DeskPage 2July 18, 2006

xc (with attachment):

W.D. Travers, Regional AdministratorU.S. Nuclear Regulatory Commission, Region IIAtlanta Federal Center61 Forsyth St., SW, Suite 23T85Atlanta, GA 30303

E.F. Guthrie, Senior Resident InspectorU.S. Nuclear Regulatory CommissionCatawba Nuclear Station

J.F. Stang, Jr., Senior Project Manager (addressee only)U.S. Nuclear Regulatory CommissionMail Stop 8-H4AWashington, D.C. 20555-0001

Page 3: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

4-

Steam Generator Outage Summary Report

Catawba Unit 2 2006Outage EOC 14

Location: 4800 Concord Road, York South Carolina 29745

NRC Docket No. 50-414

National Board No. 173

Commercial Service Date: August 19, 1986

Owner: Duke Energy Corporation526 South Church St.

Charlotte, N.C. 28201-1006

Revision 0

. 0

Prepared By:

Reviewed By.. a 'W,.

Date: 7-/13--2ý6i•

Date: "- 3 2zo" ,

Date: "77/3/0

V

Approved By:

Copy No. Assigned To: U±SNŽRC

Controlled: C eA Uncontrolled:

Page 4: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Controlled Distribution

Copy No.

Original

Assigned To

Catawba Nuclear StationDocument ControlMaster FileCN-208.21

NRC Document Control1

Uncontrolled Distribution

2 Hartford Steam BoilerInspection and InsuranceCo. (AIA)

Electronic Steam GeneratorDesktop

Page 5: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Page 1 of 20

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS

As required by the Provisions of the ASME Code Rules

1. Owner: Duke Energy Corporation, 526 S. Church St.. Charlotte, NC 28201-1006(Name and Address of Owner)

2. Plant: Catawba Nuclear Station, 4800 Concord Road, York, S. C. 29745(Name and Address of Plant)

3.

4.

5.

6.

7.

Plant Unit: 2

Owner Certificate of Authorization (if required)

Commercial Service Date: Augrust 19, 1986

National Board Number for Unit 173

Components Inspected:

N/A

Component Manufacturer

Steam Generator 2A Westinghouse

Steam Generator 2B Westinghouse

Steam Generator 2C Westinghouse

Steam Generator 2D Westinghouse

Manufacturer State or NationalSerial No. Province No. Board No.

1923 N/A 4

1922 N/A 3

1921 N/A 2

1924 N/A 5

Note: Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is81/2 in. x 11 in., (2) information in items 1 through 6 on this data report is included on each sheet, and(3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Page 6: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Page 2 of 20

FORM NIS-1 (Back)

8. Examination Dates 10/24/2004 to 04/24/2006

9. Inspection Period Identification:

10. Inspection Interval Identification:

11. Applicable Edition of Section XI

12. Date/Revision of Inspection Plan:

#3

#2

1989 Addenda None

Per Technical Specification (5.5.9)

13. Abstract of Examinations and Test. Include a list of examinations and tests and a statementconcerning status of work required for the Inspection Plan.

14. Abstract of Results of Examination and Tests.

15. Abstract of Corrective Measures.

We certify that a) the statements made in this report are correct b) the examinations and tests meetthe Inspection Plan as required by the ASME Code, Section XI, and c) corrective measures takenconform to the rules of the ASME Code, Section XI.

Certificate of Authorization No. (if applicable) NA Expiration Date NA

Date U4',j 1'3 20 104 Signed Duke Energy Corp. By ! •/i 4t-e"

CERTIFICATE OF INSERVICE INSPECTION

[, the undersigned,iholding a valid commission issued by the National Board of Boiler and PressureVessel Inspectors and the State of Province of NC employed by *The HartfordSteam Boiler Inspection and Insurance Company of Connecticut have inspected the componentsdescribed in this Owners' Report during the period 03/27/2006 to 07/13/2006and state that to the best of my knowledge and belief, the Owner has performed examinations andtests and taken corrective measures described in the Ownersf Report in accordance with the InspectionPlan and as required by the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations, test, and corrective measures described in this Ownersi Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personaln or property dam e or a loss of any kind arising from or connected with this inspection

An vN jy Commissions NC 978

Inspector's Signature National Board, State, Province, and Endorsements

Date 20......... 2-Z"".... 20

* The Hartford Steam Boiler Inspection & Insurance Company of Connecticut (HSB CT)200) Ashford Center NorthSuite 205Atlanta, GA. 30338

Page 7: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Page 3 of 20

Steam Generator Tubes InspectedCatawba Unit 2 EOC14

The following describes the scope of the Inspection performed at CatawbaUnit 2 for EOC-14 in March 2006:

A bobbin coil eddy current inspection was performed at Catawba Unit 2 EOC-14 inMarch 2006. The tubes selected for the bobbin inspection included tubes withprevious indications, tubes on the periphery of the bundle two rows deep, tubessurrounding plugged tubes and a minimum sample of 20 % of remaining tubesincluding all tubes not inspected with bobbin since EOC -10. During the outageadditional tubes were added to the inspection plan to bound possible loose partsidentified by eddy current and visual inspection. The total tubes inspected by bobbinper steam generator can be found in Table 1.

The tubesheet region was inspected with the array probe. The tubes selected for theinspection included a 20 % random sample, all periphery tubes, all of the historicaloverexpansions and 20 % of the newly identified overexpansions. Relative to thelatter, there was a new criterion developed to more consistently identifyoverexpansions. The tubesheet inspection was performed from two inches above thetop of tubesheet through the tube end. The total number of tubes inspected by thearray probe in the tubesheet region per steam generator can be found in Table 1.

Small radius u bends were also inspected by the array. The tubes selected include a20 % sample of rows one, two and ten. The tubes selected by the bobbin plan in row 3and 4 were also inspected with the array. Row ten is the first row that was notstressed relieved after bending and was sampled for monitoring purposes. The totalnumber of tubes inspected by the array in the u-bends per steam generator can befound in Table 1.

Bobbin coil indications of special interest were also inspected by the array probe. Theindication selected for array special interest were degradation identified during theinspection (I-codes, PLP, and permeability variations), 50% of previously identifieddents greater than two volts, new dents and new wear. The number of tubesinspected for special interest per steam generator can be found in Table 1.

Preheater expansions were also inspected by the array probe. The tubes selected forthe inspection include 20 % the tubes expanded at the 17C and 18C tube supportplate. The total number of tubes inspected by the array in this region per steamgenerator can be found in Table 1.

Tubes were inspected at baffle 18 C by the array probe. This region acts as a looseparts collector since it is at the bottom of the preheater. The total number of tubes

Page 8: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Page 4 of 20

inspected by the array probe in this region per steam generator can be found inTable 1.

Rolled plugs were inspected with a rotating coil probe on the hot leg. Twenty percentof the rolled plugs installed on the hot leg were inspected. The total number of tubeswith rolled plug examinations per steam generator can be found in Table 1.

All plugs were inspected visually on both the hot and cold leg sides. The totalnumber of plugged tubes visually inspected per steam generator can be found inTable 1.

There are 4578 tubes in each steam generator.

Table 1Tubes Inspected by Steam Generator

By Inspection Plan

Scope SG A SG B SG C SG DBobbin 2508 2499 2376 2601Tubesheet 1508 1159 1091 1265(array)Small radius 186 204 177 197u bends(array)Preheater 28 28 28 28expansions at17 C and 18C(array)18 C baffle 97 134 190 130region (array)Special 560 359 362 521Interest ofbobbin(array)Plug (rpc) 11 7 7 8Plug (visual) 68 90 53 85

Page 9: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Page 5 of 20

Catawba Nuclear StationSteam Generator Tubes Plugged

Refueling Outage EOC14, April 2006

Steam Generator 2B Tubes Plugged = 9Tube Row Tube Repair Method Reason for plugging

Column15 27 Mech plugged & Hot Loose Part, 1st TSP

leg stabilized15 29 Mech plugged & Hot Loose Part, 1st TSP

leg stabilized ,16 27 Mech plugged & Hot Loose Part, 1st TSP

leg stabilized16 28 Mech plugged & Hot Loose Part, 1st TSP

leg stabilized16 30 Mech plugged & Hot Loose Part, 1st TSP

leg stabilized16 31 Mech plugged & Hot Loose Part, 1st TSP

leg stabilized17 27 Mech plugged & Hot Loose Part, 1st TSP

leg stabilized18 28 Mech plugged & Hot Loose Part, 1st TSP

leg stabilized30 12 Mech plugged & Cold Cold Leg tube not expanded.

Leg tube Hard Rolled

Steam Generator 2C Tubes Plugged = 2Tube Row Tube Repair Method Reason for plugging

Column7 109 Mech plugged & hot Loose Part, 4th TSP

leg stabilized11 93 Mech plugged & Cold Preventative measure for an over-roll

_F_ leg stabilized condition at top of tubesheet

Steam Generator 2D Tubes Plugged = 2Tube Row Tube Repair Method Reason for plugging

Column-1 57 Mech plugged & hot Preventative measure for tube

leg stabilized expansion geometry at top oftubesheet.

41 60 Mech plugged & Cold Preventative measure for an over-rollleg stabilized condition at top of tubesheet

Page 10: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Page 6 of 20

Landmark Sketch to assist in locating eddycurrent information.

AV 1

081-1(

AV4 D5 STEAM GENERATORSPECIFICATIONS

TUBE INFORMATION:NO. OF TUBES = 4578MATERIAL = Inconel 600NOMINAL DIA. = 0.750"NOMINAL WALL = 0.043"ROW 1 RADIUS = 2.250"STRAIGHT LENGTH = 305.0"TUBE PITCH = 1.0625'

TUBE SUPPORT INFORMATION:TYPES = Drilled / QuatrafoilMATERIAL=405 Stainless SteelTHICKNESS = 0.75"/ 1.12"

AVB INFORMATION:MATERIAL = Chrome Plated InconelTHICKNESS = 0.296"

07H 10C

11C

12C

0411

03H

02H

01H

TSH

Tm

130C

14C

15C

16C

17C

18C

19C

I50

TWC

NOTE: Dimensions are to thecenterline

of the tube supportstructures.

Page 11: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Page 7 of 20

Tube Sheet Layout:

a. If 0 I.

1ama

aa.~

%co

a..

I'l S S I. -. m~mmm

grew..a

Om!-e nasal

al0ua

a044*1*..m4 a.... I mat

ma

M al JR As -

- ~ -~. .-----------

"a ....... ...... ........................I

--- --- ----- - -- --- - - - ---

............. .... .. . a.................... .... -Caf* GO

*3) SaN........................................... .... .... .4U.tCC. .. . . . . . ... . .aa.... ......--.... ...................

... . ... ....s .a .a ... * a.............................::: ::: ::

.. i............................m a a......................a... ..... ..... .... a.... .................... ...c...............La

... ...... ........................... GO%............ ...... .... ...... ....... ...D....D,.a .

................................ .... a.........................a--- --- . ... -- --- - --- ~

.. . . . . . .. a............. .......... ...... ..... ... .

014 Do.! co zGG ODD1 zaaaI D GOO _-zo Dl~ 1 GO -00,111 DO

a............................................................. . . . . . . . . .Sol lll•alil .c.. al a...........................................f

ma. .*.......................ccma *m

a.............,,........... '.............. ..- . ....... :• ......... .. S

44................................ 4*......................................mc...................m.............. .

- -I I :-I IIII I-I i-- -: llI- - a - -

a.... .......... _--.............................=•'_-.............-_........__..__.-.....- . ... ......... _ ... ...._- ............ :

- -a

........................................................................

.. .... . ." " 40 04 : ........m . .... . ..a.. ..m. " m cam : 4 ..... sina.... e.... .. . .... .... ...a..... a

II

I

A

U

aI

As. an mo a " all all 011 U " ft In al a M so as As AN a

0

Column 114a

Rowi10

Column 1

Attachments:

A SG 2A Eddy Current Indications and Anomalies

B SG 2B Eddy Current Indications and Anomalies

C SG 2C Eddy Current Indications and Anomalies

D SG 2D Eddy Current Indications and Anomalies

Page 12: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Page 8 of 20

Attachment ASG 2A Eddy Current Indications and Anomalies

Indication CodesSG-ACatawba Unit 2 D5 EOC14Ind Type DescriptionSAI Indication Single Axial IndicationTWD Through WallWAR Wear

Inspection techniques utilized:

BobbinThese codes are used in the following eddy current report for steam generator 2A.

Note: The reported tube indications are for those that were determined to be active inthat they are service related. All original baseline indications are not reported here.

Page 13: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Page 9 of 20

Active degradation for Steam Generator ASG ROW COL VOLTS DEG CHN IND %TW LOCATION UTIL 1 UTIL 2A 7 23 1.59 65 170 SAl TEH +0.00

30 13 1.45 0 P4 TWD 19 AV3 0.09 WAR30 23 0.89 0 P4 TWD 12 AV2 0.15 WAR31 102 0.78 0 P4 TWD 10 AV4 -0.05 WAR

0.62 0 P4 TWD 11 AV2 -0.05 WAR31 103 2.07 0 P4 TWD 24 AV2 -0.09 WAR32 15 0.82 0 P4 TWD 13 AV2 0.03 WAR33 14 0.41 0 P4 TWD 6 AV4 0.09 WAR33 93 1.03 0 P4 TWD 16 AV2 0.05 WAR33 99 0.53 0 P4 TWD 10 AV2 -0.08 WAR33 100 1.33 0 P4 TWD 18 AV3 0.00 WAR34 99 0.81 0 P4 TWD 13 AV4 0.00 WAR

0.62 0 P4 TWD 10 AV3 0.00 WAR35 16 1.65 0 P4 TWD 21 AV3 0.15 WAR

1.19 0 P4 TWD 17 AV2 0.15 WAR35 28 1.85 0 P4 TWD 23 AV3 0.00 WAR37 17 1.19 0 P4 TWD 17 AV3 0.12 WAR

0.69 0 P4 TWD 11 AV2 0.09 WAR37 27 1.01 0 P4 TWD 17 AV2 -0.03 WAR37 39 0.63 0 P4 TWD 8 AV2 0.19 WAR37 77 1.18 0 P4 TWD 17 AV4 0.00 WAR

1.41 0 P4 TWD 19 AV3 0.07 WAR1.54 0 P4 TWD 20 AV2 0.19 WAR

38 17 1.18 0 P4 TWD 17 AV4 0.09 WAR1.37 0 P4 TWD 18 AV3 0.17 WAR1.15 0 P4 TWD 16 AV1 0.03 WAR

38 21 1.31 0 P4 TWD 18 AV2 0.00 WAR38 22 0.85 0 P4 TWD 13 AV3 -0.09 WAR

0.94 0 P4 TWD 14 AV2 -0.18 WAR38 23 0.7 0 P4 TWD 11 AV2 0.08 WAR38 25 0.9 0 P4 TWD 14 AV3 0.00 WAR38 89 0.84 0 P4 TWD 14 AV3 -0.08 WAR

0.94 0 P4 TWD 15 AV2 0.08 WAR38 91 0.87 0 P4 TWD 14 AV4 0.00 WAR

0.92 0 P4 TWD 15 AV2 0.00 WAR0.41 0 P4 TWD 9 AV4 -0.05 WAR0.9 0 P4 TWD 16 AV2 0.00 WAR

38 93 1.16 0 P4 TWD 17 AV2 -0.05 WAR38 96 0.55 0 P4 TWD 10 AV4 -0.19 WAR

1.15 0 P4 TWD 17 AV3 0.00 WAR2.8 0 P4 TWD 28 AV2 -0.24 WAR

38 97 1.18 0 P4 TWD 17 AV4 0.00 WAR1.73 0 P4 TWD 22 AV3 -0.16 WAR4.15 0 P4 TWD 35 AV2 0.00 WAR

38 98 0.73 0 P4 TWD 12 AV4 -0.08 WAR0.99 0 P4 TWD 15 AV3 -0.05 WAR1.19 0 P4 TWD 17 AV2 -0.16 WAR

39 21 0.71 0 P4 TWD 10 AV2 -0.03 WAR

Page 14: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Page 10 of 20

SG ROW COL VOLTS EA 40 18 3.08

40 94 0.722.11

40 95 1.331.76

41 30 0.6341 44 0.74

1.341.48

41 81 0.791.472.15

41 83 1.091.671.47

41 85 1.9441 90 0.9641 92 0.63

1.6541 93 0.66

0.9941 94 0.82

2.991.67

42 81 0.360.82

42 85 1.062.36

42 91 1.0243 23 0.94

0.7343 91 1.44

1.071.120.631.320.940.990.48

44 23 1.45.262.061.34

44 25 1.151.18

44 31 0.6444 90 0.6344 92 0.65

1.1

:EG CHN IND %TW LOCATION UTIL 1 UTIL 20 P4 TWD 30 AV3 0.00 WAR0 P4 TWD 12 AV4 0.00 WAR0 P4 TWD 25 AV2 -0.03 WAR0 P4 TWD 18 AV4 -0.03 WAR0 P4 TWD 22 AV2 0.00 WAR0 P4 TWD 10 AV2 0.03 WAR0 P4 TWD 11 AV3 0.00 WAR0 P4 TWD 17 AV2 0.06 WAR0 P4 TWD 18 AVM 0.00 WAR0 P4 TWD 13 AV4 0.00 WAR0 P4 TWD 20 AV3 0.00 WAR0 P4 TWD 25 AV2 0.00 WAR0 P4 TWD 16 AV4 0.00 WAR0 P4 TWD 21 AV3 0.00 WAR0 P4 TWD 20 AV2 0.00 WAR0 P4 TWD 23 AV3 0.00 WAR0 P4 TWD 15 AV3 0.00 WAR0 P4 TWD 10 AV4 -0.10 WAR0 P4 TWD 21 AV3 0.00 WAR0 P4 TWD 12 AV4 -0.05 WAR0 P4 TWD 15 AV3 0.00 WAR0 P4 TWD 13 AV4 -0.05 WAR0 P4 TWD 30 AV3 0.03 WAR0 P4 TWD 21 AV2 0.05 WAR0 P4 TWD 10 AV4 0.12 WAR0 P4 TWD 16 AV2 -0.25 WAR0 P4 TWD 19 AV3 0.00 WAR0 P4 TWD 28 AV2 0.00 WAR0 P4 TWD 16 AV3 0.00 WAR0 P4 TWD 15 AV2 0.12 WAR0 P4 TWD 10 AVM 0.00 WAR0 P4 TWD 19 AV4 0.00 WAR0 P4 TWD 16 AV3 0.00 WAR0 P4 TWD 17 AV2 0.00 WAR0 P4 TWD 11 AVM 0.00 WAR0 P4 TWD 20 AV4 -0.05 WAR0 P4 TWD 16 AV3 -0.03 WAR0 P4 TWD 17 AV2 0.08 WAR0 P4 TWD 10 AVM 0.05 WAR0 P4 TWD 19 AV4 0.13 WAR0 P4 TWD 38 AV3 0.00 WAR0 P4 TWD 24 AV2 -0.03 WAR0 P4 TWD 17 AVM 0.14 WAR0 P4 TWD 17 AV3 0.09 WAR0 P4 TWD 17 AV2 0.09 WAR0 P4 TWD 8 AV2 0.12 WAR0 P4 TWD 10 AV3 0.00 WAR0 P4 TWD 11 AV4 0.00 WAR0 P4 TWD 16 AV3 0.00 WAR

Page 15: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Page 11 of 20

SG ROW COL VOLTS DEG CHN IND %TW LOCATION UTIL 1 UTIL 2A 45 26 2.34 0 P4 TWD 26 AV3 0.12 WAR

0.9 0 P4 TWD 13 AV2 0.00 WAR45 90 1.19 0 P4 TWD 17 AV3 0.00 WAR45 91 1.9 0 P4 TWD 23 AV4 0.00 WAR

1.11 0 P4 TWD 16 AV3 -0.05 WAR1.15 0 P4 TWD 17 AV2 -0.03 WAR

47 27 2.7 0 P4 TWD 29 AV3 -0.04 WAR1.05 0 P4 TWO 18 AV2 -0.03 WAR

48 85 0.96 0 P4 TWD 15 AV4 0.00 WAR0.7 0 P4 TWD 12 AV3 0.00 WAR

48 86 0.53 0 P4 TWD 13 AV4 0.00 WAR0.51 0 P4 TWD 12 AV3 0.00 WAR

49 35 0.68 0 P4 TWD 10 AV1 0.07 WAR49 70 0.67 0 P4 TWD 12 AV1 0.00 WAR

Page 16: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Page 12 of 20

Attachment BSG 2B Eddy Current Indications and Anomalies

Indication CodesSG-BCatawba Unit 2 D5 EOC14Ind Type Description

CHG Change in IndicationMAI Indication Multiple Axial IndicationNEX Anomaly No ExpansionNQI Indication Non-Quantifiable IndicationOR Data QualitySAI Indication Single Axial IndicationSCI Indication Single Circumferential IndicationSVI Indication Single Volumetric IndicationTWD Through WallWAR Wear

These codes are used in the following eddy current report for steam generator 2B.

Note: The reported tube indications are for those that were determined to be active in

that they are service related. All original baseline indications are not reported here.

Page 17: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Page 13 of 20

Active degradation for Steam Generator BSG ROW COL VOLTS DEG CHN IND %/oTW LOCATION

B 1 21 10.821 42 7.681 91 5.762 32 1.672 70 3.112 82 3.442 83 2.573 21 9.813 29 6.353 55 4.564 34 3.385 31 2.455 82 6.746 81 1.416 82 2.019 76 8.2210 81 3.2911 82 1.0612 82 1.0612 92 3.4614 81 1.2115 27 0.2815 29 0.8815 56 1.2216 27 1

0.410.79

16 28 0.470.82

16 30 0.330.85

16 31 0.2820 32 3.924 63 3.2925 31 1.5727 60 1.7130 12 3.1130 21 0.6830 104 0.75

0.6432 103 1.01

0.850.92

36 98 0.7436 99 0.537 99 0.9438 75 0.8239 59 0.344 91 1.17

15285824311718243912921171542629

2818253518981450

10713211512288110132861615400

326100000000000

94 SCI70 MAI

182 SAI158 MAI166 SAI26 SAI38 SAI162 SAI162 SAI170 SAI150 SAI38 SAI122 SAI26 SAI170 SAI38 SAI162 SAI146 SAI122 SAI182 SAI58 SAI54 SVI

134 SVIP4 TWD 1958 SVI10 SVIP1 N0IP1 N01118 SVIP1 N0I6 SVI

158 SVI158 SAI70 SAI26 SAIP4 TWD 22193 NEX10 SAIP4 TWD 13P4 TWD 11P4 TWD 17P4 TWD 15P4 TWD 16P4 TWD 13P4 TWD 11P4 TWD 16P4 TWD 15P4 TWD 7P4 TWD 19

TEH +0.03TEH +0.09TEH +0.09TEH +0.12TEH +0.30TEH +0.03TEH +0.03TEH +0.06TEH +0.35TEH +0.04TEH +0.27TEH +0.04TEH +0.07TEH +0.24TEH +0.07

TEH +0.09 TO+0.23TEH +0.06TEH +0.10TEH +0.06TEH +0.06TEH +0.2401H +0.6401H +0.51AV4 0.24

01H +0.5901H +0.4701H 0.5901H 0.40

01H +0.5201H 0.49

01H +0.5401H +0.64TEH +0.05TEH +0.10TEH +0.06

AV2 0.24TEC 1.00TO 21.20

TEH +0.06AV3 0.12AVi -0.03AV4 0.08AV3 0.11AV2 0.19AV4 0.00AV4 0.06AV4 0.15AV2 0.00AV4 0.00AV2 0.00

UTIL 1 UTIL 2

WAR

CHG

WAR

WARWARWARWARWARWARWARWARWARWARWAR

OR

Page 18: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Page 14 of 20

SG ROW COL VOLTS DEG CHN IND %TW

B 45 24 0.52 0 P4 TWD 11

47 27 1.02 0 P4 TWD 161.47 0 P4 TWD 20

0.47 0 P4 TWD 10

47 88 0.81 0 P4 TWD 140.86 0 P4 TWD 15

LOCATIONAV4 -0.03AV4 0.00AV3 0.03AV2 -0.06AV4 0.00AV2 0.00

UTIL 1 UTIL 2WARWARWARWARWARWAR

Page 19: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Page 15 of 20

Attachment CSG 2C Eddy Current Indications and Anomalies

Indication CodesSG - CCatawba Unit 2 D5 EOC14Ind Type Description

CHG Change in IndicationNQI Indication Non-Quantifiable IndicationSAI Indication Single Axial IndicationSVI Indication Single Volumetric IndicationTWD Through WallVOL VolumetricWAR Wear

These codes are used in the following eddy current report for steam generator 2C.

Note: The reported tube indications are for those that were determined to be active inthat they are service related. All original baseline indications are not reported here.

Page 20: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Er

Page 16 of 20

Active degradation for Steam Generator CSG ROW COL VOLTS DEG

C 1 19 2.583 51 6.27 109 0.82

1.2327 9 2.6228 10 1.0128 11 0.828 105 1.2329 10 0.8

0.7529 12 0.84

1.1329 14 0.8130 15 1.431 11 0.6231 12 1.6533 12 1.37

133 14 1.02

1.7233 55 1.7733 100 0.7733 102 0.736 25 0.4236 37 0.4136 98 1.0838 17 0.59

1.470.65

38 23 0.530.58

38 34 0.838 97 1.1638 99 3.33

1.1339 17 0.5239 18 1.1939 27 0.96

0.7639 94 1.2339 97 0.97

0.510.74

40 20 1.6740 22 0.6140 27 0.9541 20 0.51

0.630.65

2616784127000000000000000000000000000000000000000000000

CHN IND %TW LOCATION UTIL 1 UTIL 2

58 SAl TEH +0.25146 SAI TEH +0.09186 SVI 04H -0.75195 NQI 04H -0.89 CHGP4 TWD 26 AV2 -0.03 WARP4 TWD 15 AV2 0.00 WARP4 TWD 12 AV2 -0.08 WARP4 TWD 18 AV3 0.00 WARP4 TWD 13 AV3 -0.05 WARP4 TWD 12 AV2 -0.15 WARP4 TWD 13 AV3 0.08 WARP4 TWD 16 AV2 0.03 WARP4 TWD 13 AV3 -0.08 WARP4 TWD 18 AV4 0.15 WARP4 TWD 9 AVM 0.03 WARP4 TWD 21 AV3 0.14 WARP4 TWD 19 AV2 -0.13 WARP4 TWD 16 AV1 0.00 WARP4 TWD 15 AV3 -0.08 WARP4 TWD 22 AV2 -0.13 WARP4 TWD 23 AV3 0.00 WARP4 TWD 13 AV2 0.14 WARP4 TWD 12 AV2 0.13 WARP4 TWD 8 AV2 0.03 WARP4 TWD 9 AV2 0.06 WARP4 TWD 16 AV2 0.11 WARP4 TWD 9 AV4 -0.05 WARP4 TWD 18 AV2 -0.08 WARP4 TWD 10 AV1 0.00 WARP4 TWD 10 AV4 0.05 WARP4 TWD 11 AV2 0.00 WARP4 TWD 14 AV2 0.30 WARP4 TWD 18 AV2 -0.05 WARP4 TWD 31 AV4 0.21 WARP4 TWD 17 AV3 0.02 WARP4 TWD 9 AV1 0.00 WARP4 TWD 18 AV2 -0.03 WARP4 TWD 15 AV3 -0.03 WARP4 TWD 13 AV2 0.21 WARP4 TWD 18 AV3 0.00 WARP4 TWD 16 AV4 0.00 WARP4 TWD 11 AV3 0.00 WARP4 TWD 14 AV2 0.00 WARP4 TWD 23 AV2 -0.05 WARP4 TWD 12 AV2 -0.05 WARP4 TWD 15 AV2 0.05 WARP4 TWD 10 AV3 0.05 WARP4 TWD 12 AV2 -0.03 WARP4 TWD 12 AVM -0.03 WAR

Page 21: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Page 17 of 20

SG ROW COL VOLTS DEG CHN IND %TW LOCATION UTIL 1 UTIL 2

C 43 93 0.48 0 P4 TWD 10 AV4 0.00 WAR0.39 0 P4 TWD 9 AV3 0.00 WAR

0.83 0 P4 TWD 15 AV2 0.00 WAR44 81 0.55 0 P4 TWO 12 AV4 0.00 WAR

2.75 0 P4 TWD 29 AV2 0.30 WAR1.48 0 P4 TWD 21 AV3 0.27 WAR

48 48 0.62 77 P19 VOL AVM +0.00 WAR0.88 143 P2 VOL AV4 +0.00 WAR

49 59 1.48 102 P30 TWD 21 13C +0.00 WAR

2.55 117 P23 VOL 13C +0.34 WAR2.61 0 P2 NQI 13C 0.28 WAR

49 76 1.99 0 P4 TWD 26 AVM 0.00 WAR

Page 22: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Page 18 of 20

Attachment DSG 2D Eddy Current Indications and Anomalies

Indication CodesSG - DCatawba Unit 2 D5 EOC14Ind Type Description

MAI Indication Multiple Axial IndicationNQI Indication Non-Quantifiable IndicationSCI Indication Single Circumferential IndicationTWD Through WallVOL Indication VolumetricWAR Wear

These codes are used in the following eddy current report for steam generator 2D.

Note: The reported tube indications are for those that were determined to be active inthat they are service related. All original baseline indications are not reported here.

Page 23: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

4 Page 19 of 20

Active degradation for SteanSG ROW COL VOLTS DEG CHN IND

D 25 107 2.060.77

27 107 1.4928 10 0.92

0.6528 16 1.8728 71 1.7928 105 1.4929 104 1.0230 102 2.4333 13 1.13

2.31.54

33 79 1.0934 98 1.8234 99 1.2234 100 1.1135 14 1.5

4.8435 17 6.5535 43 4.2935 96 0.5436 16 1.35

1.124.821.37

36 65 2.3136 93 1.2236 94 1.06

0.6136 96 0.77

1.4836 97 1.5936 98 1.3237 17 1.71

1.6738 18 2.24

2.5638 19 1.4138 20 1.72

1.538 21 1.5138 26 1.0838 64 1.9938 78 1.8238 90 1.0638 93 2.53

0.8939 81 0.87

O P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P4

43135

0 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P40 P4

TWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWD

98 SCI98 SCI

TWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWDTWD

n Generator D%TW LOCATION UTIL 1 UTIL 2

18 AV2 0.00 WAR8 AV3 0.00 WAR

14 AV2 0.27 WAR10 AV4 0.00 WAR

8 AV3 0.00 WAR17 13C -0.47 WAR18 AV2 -0.31 WAR14 AV2 0.00 WAR10 AV2 0.10 WAR21 AV3 0.09 WAR12 AV4 0.00 WAR20 AV2 0.00 WAR15 AV3 0.00 WAR11 AV2 -0.03 WAR18 AV2 0.00 WAR13 AV2 0.09 WAR12 AV3 -0.03 WAR15 AV4 0.00 WAR32 AV2 0.00 WAR

TEH +0.31TEH +0.42

6 AV2 0.09 WAR13 AV4 0.00 WAR11 AV3 -0.06 WAR31 AV2 0.00 WAR13 AVM 0.00 WAR20 AV3 0.33 WAR13 AV2 0.03 WAR11 AV2 0.00 WAR7 AVM 0.00 WAR9 AV3 0.00 WAR

15 AV2 -0.03 WAR15 AV2 0.00 WAR14 AV3 0.06 WAR

.17 AV4 0.00 WAR17 AV2 -0.03 WAR19 AV4 0.00 WAR21 AV2 0.14 WAR13 AV2 0.09 WAR16 AV4 0.00 WAR14 AV2 0.00 WAR14 AV2 0.00 WAR11 AV2 0.38 WAR17 AV2 0.00 WAR17 AV3 -0.12 WAR12 AV2 -0.12 WAR21 AV2 0.00 WAR10 AV3 0.06 WAR10 AV2 0.21 WAR

Page 24: Catawba, Unit 2 - Steam Generator Outage Summary ...12C 0411 03H 02H 01H TSH Tm 130C 14C 15C 16C 17C 18C 19C I50 TWC NOTE: Dimensions are to the centerline of the tube support structures.

Page 20 of 20

SG ROW COL VOLTS DEG CHN INDD 39 96 1.4

39 98 0.9540 93 1.0940 94 1.52

1.5440 97 0.93

0.8541 20 1.4641 59 4.57

2.8341 60 3.35

2.8241 77 0.77

2.0442 23 1.49

2.6342 30 1.4842 32 1.4742 64 1.01

3.0542 85 1.04

1.2143 22 2.29

0.983.37

43 29 1.243 78 4.58

2.580.89

44 24 1.6544 46 2.2244 90 0.4344 91 0.7145 52 2.3245 91 0.76

0.6247 87 0.8548 78 4.5248 82 0.8649 37 0.6949 74 1.0849 84 0.67

0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD

33 138 MAI11 34 SCI81 138 MAI14 46 SCI0P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD

110 58 VOL98 P2 NQI0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P2 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD0 P4 TWD

%TW LOCATION UTIL 1 UTIL 214 AV3 0.00 WAR10 AV1 0.12 WAR12 AV2 0.15 WAR15 AV3 0.17 WAR16 AV2 0.00 WAR10 AV3 -0.06 WAR10 AVI 0.06 WAR15 AV4 0.00 WAR

TEH +0.37TEH +0.77TEH +0.31TEH +0.55

9 AV3 -0.03 WAR19 AV2 0.24 WAR14 AV4 0.00 WAR21 AV2 0.00 WAR14 AV2 0.30 WAR14 AV2 0.15 WAR

13C -0.1513C 0.06 WAR

11 AV3 -0.03 WAR13 AV2 0.03 WAR21 AV4 0.00 WAR11 AV2 0.00 WAR26 AV3 0.00 WAR13 AV2 0.00 WAR31 AV3 0.00 WAR22 AV2 -0.06 WAR9 AV1 0.18 WAR

15 AV3 -0.25 WAR20 AV3 -0.21 WAR

5 AV1 0.00 WAR8 AV4 0.21 WAR

18 15C -0.46 WAR9 AV4 0.00 WAR7 AV2 0.21 WAR9 AV4 0.10 WAR

31 AV4 -0.31 WAR9 AV1 0.00 WAR

10 AV1 -0.03 WAR12 AV4 0.24 WAR8 AV1 0.13 WAR