IEEE NGBASE-T SG January 2013 Larsen_01_0113_NGBT 1 Category 8 Structured Cabling Channel Demonstration by Commscope Wayne Larsen
Transcript

IEEE NGBASE-T SG January 2013 Larsen_01_0113_NGBT

1

Category 8 Structured Cabling ChannelDemonstration by Commscope

Wayne Larsen

IEEE NGBASE-T SG January 2013 Larsen_01_0113_NGBT

2

Supporters

• Paul Kish – Belden• George Zimmerman – CME Consulting (Commscope)• Mike Grimwood – Broadcom• Peter Wu – Marvell• Andy Jimenez – Anixter• Antoine Pelletier – Intertek• Sterling Vaden – Optical Cable Corporation• Arvind Patel – Psiber • Harshang Pandya – Psiber• Gavin Parnaby - Marvell

IEEE NGBASE-T SG January 2013 Larsen_01_0113_NGBT

3

Commscope Cat 8 Cabling

• This contribution is being made to show the technical feasibility of a category 8 cabling system

• Broad market potential and compatibility are supported by the RJ-45 connector

• These complete cabling channels consist of the following– One long and one short channel– Horizontal cable– Two connectors– A patch cord at each end of each channel

IEEE NGBASE-T SG January 2013 Larsen_01_0113_NGBT

4

Commscope Cat 8 Cabling

• Differences from the previous contribution– Complete channel, not only permanent link

– All components from the same vendor• Demonstrates existence of two connecting

hardware manufacturers

IEEE NGBASE-T SG January 2013 Larsen_01_0113_NGBT

5

Commscope short channel IL

0

10

20

30

40

50

60

0 200 400 600 800 1000 1200 1400 1600 1800 2000

pair 1pair 2pair 3pair 4limit

IEEE NGBASE-T SG January 2013 Larsen_01_0113_NGBT

6

Commscope long channel insertion loss

0

10

20

30

40

50

60

0 200 400 600 800 1000 1200 1400 1600 1800 2000

pair 1pair 2pair 3pair 4limit

IEEE NGBASE-T SG January 2013 Larsen_01_0113_NGBT

7

Commscope short channel return loss

0

10

20

30

40

50

60

0 200 400 600 800 1000 1200 1400 1600 1800 2000

pair 1 fwdpair 2 fwdpair 3 fwdpair 4 fwdpair 1 revpair 2 revpair 3 revpair 4 revLimit

IEEE NGBASE-T SG January 2013 Larsen_01_0113_NGBT

8

Commscope long channel return loss

0

10

20

30

40

50

60

0 200 400 600 800 1000 1200 1400 1600 1800 2000

pair 1 fwdpair 2 fwdpair 3 fwdpair 4 fwdpair 1 revpair 2 revpair 3 revpair 4 revLimit

IEEE NGBASE-T SG January 2013 Larsen_01_0113_NGBT

9

NEXT - Commscope channels

0

10

20

30

40

50

60

70

80

90

100

0 200 400 600 800 1000 1200 1400 1600 1800 2000

short ch pairs 12 short ch pairs 13short ch pairs 14 short ch pairs 23short ch pairs 24 short ch pairs 34limit long ch pairs 12long ch pairs 13 long ch pairs 14long ch pairs 23 long ch pairs 24long ch pairs 34

IEEE NGBASE-T SG January 2013 Larsen_01_0113_NGBT

10

ACRF Commscope short channel

0

10

20

30

40

50

60

70

80

90

0 200 400 600 800 1000 1200 1400 1600 1800 2000

ACRF channel limit

ACRF 13 fwd

ACRF 13 rev

ACRF 23 fwd

ACRF 23 rev

ACRF 34 fwd

ACRF 34 rev

ACRF 12 fwd

ACRF 12 rev

ACRF 14 fwd

ACRF 14 rev

ACRF 24 fwd

ACRF 24 rev

IEEE NGBASE-T SG January 2013 Larsen_01_0113_NGBT

11

ACRF Commscope short channel

0

10

20

30

40

50

60

70

80

90

0 200 400 600 800 1000 1200 1400 1600 1800 2000

ACRF channel limit

ACRF 13 fwd

ACRF 13 rev

ACRF 23 fwd

ACRF 23 rev

ACRF 34 fwd

ACRF 34 rev

ACRF 12 fwd

ACRF 12 rev

ACRF 14 fwd

ACRF 14 rev

ACRF 24 fwd

ACRF 24 rev

IEEE NGBASE-T SG January 2013 Larsen_01_0113_NGBT

12

Conclusions

• Verification that the channel models are correct, based on another manufacturer’s connecting hardware

• So far two cabling companies have demonstrated prototype category 8 connectors and one has demonstrated category 8 cable

• These designs are expected to improve in the future leading to fully meeting all requirements in production

• Technical feasibility, broad market potential, and compatibility are supported by this data