+ All Categories
Home > Documents > CATS TPR Thermal-15W-2.24 · Title: CATS_TPR Thermal-15W-2.24.indd Created Date: 3/6/2018 2:17:15...

CATS TPR Thermal-15W-2.24 · Title: CATS_TPR Thermal-15W-2.24.indd Created Date: 3/6/2018 2:17:15...

Date post: 25-Aug-2020
Category:
Upload: others
View: 4 times
Download: 0 times
Share this document with a friend
4
CATS TPR-THERMAL-15W Qi CERTIFIED MEASUREMENT TOOL With over 25 years of experience, nok9 is the world-leading supplier of complete solutions for reference test tools in wireless charging and optical media. TPR-Thermal-15W measures heat generated in a mobile device during charging Fullfils Qi specification requirements for Extended Power Profile (1.2.5)
Transcript
Page 1: CATS TPR Thermal-15W-2.24 · Title: CATS_TPR Thermal-15W-2.24.indd Created Date: 3/6/2018 2:17:15 PM

CATS™

TPR-THERMAL-15WQi CERTIFIEDMEASUREMENT TOOL

With over 25 years of experience, nok9 is the world-leading supplierof complete solutions for reference test tools in wireless chargingand optical media.

CATSTPR-THERMAL-15W

MEASUREMENT TOOL

With over 25 years of experience, nok9 is the world-leading supplierof complete solutions for reference

TPR-Thermal-15W measures heat generated in a mobile

device during charging

Fullfi ls Qi specifi cation requirements for Extended Power

Profi le (1.2.5)

Page 2: CATS TPR Thermal-15W-2.24 · Title: CATS_TPR Thermal-15W-2.24.indd Created Date: 3/6/2018 2:17:15 PM

The TPR-Thermal-15W enables reliable measurement of the heat generated in a mobile device during charging. TPR-Thermal is approved and certified by WPC, the Wireless Power Consortium.

Example of measure-ments displayed innok9 Advanced modeuser interface, whenrunning measure-ments with TPR-Ther-mal-15W.

Schematic diagram ofCATS II BST TesterSystem equippedwith TPR-Termal-15W.

Computer Interface

BST

ThermoMux

TPR-Thermal

Coil

TP1

TP2

Dem

od

TP3

AU

X1

TP4

AU

X2

Ext

Load

Trig

g

STATE-OF-THE-ART FEATURES IN EVERY TPR-THERMAL-15W

· Connects easily to nok9’s CATS Base Station Testers

· Measures ambient temperature and temperature inside the receiver

· Includes an 8-channel ThermoMux (Connected via USB to BST)

· Includes measurement GUI - Convenient user interface

· Provides graphical presentation of ambient and inside receiver temperatures,

and the difference between them

· 600-mm, high-quality cable with gold 5-pin XLR connector

· Maintains measurement accuracy of +/- 1 °C

· Compatible with nok9 Software version 17.1 and onward

TPR-THERMAL-15W Qi CERTIFIED MEASUREMENT TOOL 2

Page 3: CATS TPR Thermal-15W-2.24 · Title: CATS_TPR Thermal-15W-2.24.indd Created Date: 3/6/2018 2:17:15 PM

3

Every test tool from nok9 is the product of over 25 years of specialized expertise, and this continues

to grow as we strive to ensure our testing solutions achieve the most reliable results possible. Each of

our test tools are hand-built with the highest quality components and put through rigorous testing,

quality control and calibration before delivery.

nok9 collaborates closely with the Wireless Power Consortium (WPC) as well as a global network of

manufacturers and test labs, allowing us to offer unique and far-ranging technical support. This also

lets us adhere to the most updated Qi specifications, design tests based on your needs, troubleshoot,

and provide the latest updates and accessories. We also offer advanced training to help you use our

instruments effectively.

As an active member of the WPC, we contribute our knowledge and experience towards developing

improved Qi specifications, and provide certified testing solutions that drive the Qi wireless powering

technology forward. nok9 test systems are the only test instruments that are certified by the WPC.

Under nok9 standards, nok9 also develops specialized interface standards towards expanding

the possibilities of wireless charging technology. Published standards developed by nok9 include

Rainbow, CE4A Extension and Typhoon.

For more information, visit nok9.com.

TPR-THERMAL-15W Qi CERTIFIED MEASUREMENT TOOL

WE SET THE STANDARD

Qi SPECIFICATION

TPR-THERMAL-15W

The block diagram of the thermal Test Power Receiver (TPR-THERMAL-15W)

is identical to the block diagram of Test Power Receiver #MP1B.

CONFIGURATION

The dual resonant circuit of TPR-THERMAL-15W is identical to the dual resonant circuit in Test Power Receiver

#MP1B, except that:

• The Shielding is thermally coupled to the mounting box top cover.

• A thermocouple (type K, Wire Gauge 40) is attached to the top cover recess interfacing with the Shielding.

The assembly is mounted inside an enclosure, such that the distance from the bottom face of the Secondary

Coil to the outer surface of the box—the Interface Surface—is 2.5 mm. The material between the Interface

Surface and the Secondary Coil consists of (the stereo lithography material) HMPU6, or a material having

equivalent thermal and magnetic properties. The top cover of the enclosure acts as a heat sink and consists

of aluminum. The dimensions of the top-cover recess that is thermally coupled to the Shielding are 53×36×7.5

mm3, and the dimensions of the top cover part facing the outside of the enclosure are 130×70×2.2 mm3. The

top-cover recess makes physical contact with the Shielding and is provided with thermal paste to ensure good

thermal contact. In addition, the top-cover recess contains a hole in which the thermocouple is inserted, with

thermal paste ensuring good thermal contact. See Annex A.9 for a sketch of TPR-THERMAL-15W.

OPERATING POINT

TPR-THERMAL-15W operates at a rectified voltage of 12 V at a resistive load of 9.6 Ω.

Page 4: CATS TPR Thermal-15W-2.24 · Title: CATS_TPR Thermal-15W-2.24.indd Created Date: 3/6/2018 2:17:15 PM

TRUSTED BY THE TOP BRANDS

CATS II REFERENCE TESTERS

BASE TESTERS

CATS I REFERENCE TESTERS

EUROPE +46 40 690 49 00 • USA (TN) +1 818 540 3100 • FAR EAST +852 2314 8736 • [email protected] • www.nok9.com

nok9 is a contributing member of the Wireless Power Consortium


Recommended