© 2019 CEM Corporation Print-Ready Poster Maximization of Analytical Cannabis Extractions and Sample Clean-Up Through the Use of a Single Process Combined Pressurized Fluid and Dispersive Solid Extraction (EDGE) Page 1 of 3 Maximization of Analytical Cannabis Extractions and Sample Clean-Up Through the Use of a Single Process Combined Pressurized Fluid and Dispersive Solid Extraction (EDGE) CEM Corporation Authors • Alicia D. Stell • Brittany A. Leffler • Candice A. M. Olsson Presented March 17-1, 2019 at Pittcon by Alicia D. Stell Poster Content Introduction With more states approving recreational and medical marijuana use each year, the need for accurate testing of cannabis and cannabis based products is critical. Samples ranging from flower to edibles to consumer products and more, present challenges in both sample preparation and analysis. With pesticide analysis among the most challenging. In this poster, we propose the EDGE® as a method for the extraction of pesticides from cannabis. With its patent pending Q-Cup Technology™ the EDGE can extract the cannabis, including the dispersive solid phase cleanup, in less than 7 minutes in one automated step.
Transcript
Page 1: CEM Corporation - Maximization of Analytical Cannabis ...cem.com/media/contenttype/media/literature/Poster_EDGE...Pittcon by Alicia D. Stell Poster Content Introduction With more states

© 2019 CEM Corporation

Print-Ready PosterMaximization of Analytical Cannabis Extractions and Sample Clean-Up Through the Use of a Single Process Combined Pressurized Fluid and Dispersive Solid Extraction (EDGE)

Page 1 of 3

Maximization of Analytical Cannabis Extractions and Sample Clean-Up Through the Use of a Single Process Combined Pressurized Fluid and Dispersive Solid Extraction (EDGE)

CEM Corporation Authors

• Alicia D. Stell

• Brittany A. Leffler

• Candice A. M. Olsson

Presented

March 17-1, 2019 at Pittcon by Alicia D. Stell

Poster Content

Introduction

With more states approving recreational and medical marijuana use each year, the need for accurate testing of cannabis and cannabis based products is critical. Samples ranging from flower to edibles to consumer products and more, present challenges in both sample preparation and analysis. With pesticide analysis among the most challenging. In this poster, we propose the EDGE® as a method for the extraction of pesticides from cannabis. With its patent pending Q-Cup Technology™ the EDGE can extract the cannabis, including the dispersive solid phase cleanup, in less than 7 minutes in one automated step.

Rich D
Page 2: CEM Corporation - Maximization of Analytical Cannabis ...cem.com/media/contenttype/media/literature/Poster_EDGE...Pittcon by Alicia D. Stell Poster Content Introduction With more states

© 2019 CEM Corporation

Print-Ready PosterMaximization of Analytical Cannabis Extractions and Sample Clean-Up Through the Use of a Single Process Combined Pressurized Fluid and Dispersive Solid Extraction (EDGE)

Page 2 of 3

Energized Dispersive Extraction

Q-Cup Technology combines the processes of Pressurized Fluid Extraction and Dispersive Solid Phase Extraction into one instrument.

Extracts With and Without Cleanup

% Recovery of Pesticides from Cannabis

EDGE Methods

20 mL top volume1% acetic acid in acetonitrile

40 °C

1.5 g sample

M2 and C9 Q-DiscContents of Agilent’s QuEChERS Dispersive 15 mL tube

5 mL bottom volume1% acetic acid in acetonitrile

Parameter

Pesticide

Hold Time

Abamectin

Malathion

Etoxazole

Spinosad A

2 minutes

99

117

97

106Rinse

Azoyxystrobin

Myclobutanil

Imazalil

Spiromesifen

5 mL acetic acid in acetonitrile

100

90

103

110Wash

Bifenazate

Permethrin

Imidacloprid

Tebucon

20 mL acetic acid in acetonitrile

82

95

91

91

Value

% Recovery

Page 3: CEM Corporation - Maximization of Analytical Cannabis ...cem.com/media/contenttype/media/literature/Poster_EDGE...Pittcon by Alicia D. Stell Poster Content Introduction With more states

United States (Headquarters)

800-726-3331 704-821-7015 Fax: 704-821-7894 [email protected]

France

33 (01) 69 35 57 80Fax: 33 (01) 60 19 64 91 [email protected]

Germany, Austria, Switzerland

(49) 2842-9644-0Fax: (49) 2842-9644-11 [email protected]

Ireland

+353 (0) 1 885 1752Fax: +353 (0) 1 885 1601 [email protected]

Italy

(39) 35-896224 Fax: (39) 35-891661 [email protected]

United Kingdom

(44) 1280-822873 Fax: (44) 1280-822873 [email protected]

www.cem.com

© 2019 CEM CorporationAll rights reserved. This may not be reproduced or published without written permission from CEM.

Japan

+81-3-5793-8542Fax: +81-3-5793-8543 [email protected]

Print-Ready PosterMaximization of Analytical Cannabis Extractions and Sample Clean-Up Through the Use of a Single Process Combined Pressurized Fluid and Dispersive Solid Extraction (EDGE)

Page 3 of 3

Conclusions

The EDGE, with its efficient pesticide extraction method, is ideal for cannabis testing labs that want repeatable results with one automated method and smaller sample sizes. While this study focused on the extraction of pesticides that EDGE can be used for the extraction of cannabinoids, terpenes and mycotoxins as well. We would like to thank the Washington State Department of Agriculture Chemical and Hop Laboratory for extracting the cannabis on the EDGE and running the analysis.