CERTIFICATE Certificat - Certificado- Сертификат - Zertifikat - 證書 1) APPLICANT: (who finally puts the product on the market) Elitech Technology, Inc. 1551 McCarthy Blvd, Suite 112, Milpitas, CA 95035 MANUFACTURER: Jiangsu Jingchuang Electronics Co.,Ltd No.1 Huangshan Rd. Tongshan Economic Development Zone Xuzhou Jiangsu China 2) CERTIFICATE NO.: ISETC.000820200121 FILE REFERENCE: SCC(20)-30302A-10-EMC 3) ISET MARK: 4) CAUTION ABOUT CE MARKING (Instruction for the Applicant who puts the product on the EU market): The label of the CE Marking on the left side should be not less than 5mm height. CE Marking and EC Declaration of Conformity are duties for the manufacturer or its applicant who puts the product on the market. This one is responsible to start the CE marking and certification procedure as required by the legislation in force. Only for the products which are compulsorily included into specific Directives or Regulations will be necessary to appoint a Notified Body. 5) TYPE OF PRODUCT: Air Quality Detector MODEL(S): LKC-1000E , LKC-1000S+, LKC-1000S 6) LIST OF DIRECTIVES / REGULATIONS /STANDARDS (as declared by the manufacturer itself) Electromagnetic Compatibility 2014/30/EU EN 61326-1:2013 7) NOTE: The applicant is aware about the contents and information included in the ModCOM04.06 Regulation for this type of Certificate that is considered totally accepted. The latest revision of the Regulation is available and can be downloaded from the website www.iset-italia.eu. This document is not referred to any evaluation that could be considered as included in the scope of the activities covered by the standard BS EN ISO/IEC 17065:2012 or European Regulation 765/2008. 8) REMARK: Certificate is issued on voluntary application from the Client and it gives to the applicant the right to use and affix the ISET Mark (at point 3) on their products, even if it doesn’t imply any assessment on the safety and compliance of the product. ISET declares that the only scope of the assessment is to verify the existence of the declaration issued by the manufacturer or an applicant under its own responsibilities. 9) DATE OF ISSUE: 21/01/2020 EXPIRY DATE: 20/01/2025 10) SIGNATURE: Li Zhang (On behalf of the Legal representative) This document is property of ISET Srl and any kind of reproduction is to be considered strictly forbidden. ISET S.r.l. Unipersonale Sede Legale e Uffici Cap. soc. i.v. € 10.200,00 Via Donatori di sangue, 9 - 46024 Moglia (MN) Cod. Fisc. e P.IVA Reg. Imprese 02 332 750 369 Tel. e fax +39 (0)376 598963 REA 02 332 750 369 www.iset-italia.eu [email protected] Cap. soc. i.v. MN 0221098
Transcript
Page 1: CERTIFICATE - m.media-amazon.com

CERTIFICATE Certificat - Certificado- Сертификат - Zertifikat - 證書

1) APPLICANT: (who finally puts the product on the market)

Elitech Technology, Inc.

1551 McCarthy Blvd, Suite 112, Milpitas, CA 95035

MANUFACTURER:

Jiangsu Jingchuang Electronics Co.,Ltd

No.1 Huangshan Rd. Tongshan Economic Development Zone Xuzhou Jiangsu China

2) CERTIFICATE NO.: ISETC.000820200121

FILE REFERENCE: SCC(20)-30302A-10-EMC

3) ISET MARK:

4) CAUTION ABOUT CE MARKING (Instruction for the Applicant who puts the product on the EU market):

The label of the CE Marking on the left side should be not less than 5mm height. CE Marking and EC Declaration

of Conformity are duties for the manufacturer or its applicant who puts the product on the market. This one is

responsible to start the CE marking and certification procedure as required by the legislation in force. Only for

the products which are compulsorily included into specific Directives or Regulations will be necessary to appoint a Notified Body.

5) TYPE OF PRODUCT: Air Quality Detector

MODEL(S): LKC-1000E , LKC-1000S+, LKC-1000S

6) LIST OF DIRECTIVES / REGULATIONS /STANDARDS (as declared by the manufacturer itself)

Electromagnetic Compatibility 2014/30/EU

EN 61326-1:2013

7) NOTE: The applicant is aware about the contents and information included in the ModCOM04.06 Regulation for this type

of Certificate that is considered totally accepted. The latest revision of the Regulation is available and can be downloaded

from the website www.iset-italia.eu. This document is not referred to any evaluation that could be considered as included

in the scope of the activities covered by the standard BS EN ISO/IEC 17065:2012 or European Regulation 765/2008.

8) REMARK: Certificate is issued on voluntary application from the Client and it gives to the applicant the right to use

and affix the ISET Mark (at point 3) on their products, even if it doesn’t imply any assessment on the safety and

compliance of the product. ISET declares that the only scope of the assessment is to verify the existence of the declaration

issued by the manufacturer or an applicant under its own responsibilities.

9) DATE OF ISSUE: 21/01/2020 EXPIRY DATE: 20/01/2025

10) SIGNATURE: Li Zhang

(On behalf of the Legal representative)

This document is property of ISET Srl and any kind of reproduction is to be considered strictly forbidden.

ISET S.r.l. Unipersonale Sede Legale e Uffici Cap. soc. i.v. € 10.200,00

Via Donatori di sangue, 9 - 46024 Moglia (MN) Cod. Fisc. e P.IVA Reg. Imprese 02 332 750 369

Tel. e fax +39 (0)376 598963 REA 02 332 750 369

www.iset-italia.eu [email protected] Cap. soc. i.v. MN 0221098

Page 2: CERTIFICATE - m.media-amazon.com

FCC PART 15B

TEST REPORT For

Elitech Technology, Inc.

1551 McCarthy Blvd, Suite 112, Milpitas, CA 95035

Report Type:

Amended Report

Product Type:

Air Quali ty Detector

Test Engineer: Tina Li

Report Number: RSHA200311002-00AM1

Report Date: 2020-03-30

Reviewed By: Oscar Ye EMC Manager

Prepared By: Bay Area Compliance Laboratories Corp. (Kunshan) No.248 Chenghu Road, Kunshan,Jiangsu province, China Tel: +86-0512-86175000 Fax: +86-0512-88934268 www.baclcorp.com.cn

Tested Model: LKC-1000S+ Series Model: LKC-1000E, LKC-1000S

Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

Page 3: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1

TABLE OF CONTENTS REPORT REVISION .................................................................................................................................................... 3

GENERAL INFORMATION ....................................................................................................................................... 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 4 OBJECTIVE ................................................................................................................................................................... 4 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................. 4 TEST METHODOLOGY .................................................................................................................................................. 4 TEST FACILITY ............................................................................................................................................................. 4

SYSTEM TEST CONFIGURATION .......................................................................................................................... 5 JUSTIFICATION ............................................................................................................................................................. 5 EUT EXERCISE SOFTWARE .......................................................................................................................................... 5 SPECIAL ACCESSORIES ................................................................................................................................................. 5 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 5 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 5 BLOCK DIAGRAM OF RADIATED TEST SETUP............................................................................................................... 6

SUMMARY OF TEST RESULTS ............................................................................................................................... 7

FCC §15.107 –CONDUCTED EMISSIONS ............................................................................................................... 8 APPLICABLE STANDARD .............................................................................................................................................. 8 MEASUREMENT UNCERTAINTY .................................................................................................................................... 8 EUT SETUP .................................................................................................................................................................. 8 EMI TEST RECEIVER SETUP ......................................................................................................................................... 9 TEST PROCEDURE ........................................................................................................................................................ 9 TEST EQUIPMENT LIST AND DETAILS ........................................................................................................................... 9 FACTOR & OVER LIMIT CALCULATION ........................................................................................................................ 9 TEST DATA ................................................................................................................................................................ 10

FCC §15.109 - RADIATED EMISSIONS ................................................................................................................. 12 APPLICABLE STANDARD ............................................................................................................................................ 12 MEASUREMENT UNCERTAINTY .................................................................................................................................. 12 EUT SETUP ................................................................................................................................................................ 12 EMI TEST RECEIVER SETUP ....................................................................................................................................... 13 TEST PROCEDURE ...................................................................................................................................................... 13 TEST EQUIPMENT LIST AND DETAILS ......................................................................................................................... 13 CORRECTED AMPLITUDE & MARGIN CALCULATION ................................................................................................. 13 TEST DATA ................................................................................................................................................................ 14

EXHIBIT A - EUT PHOTOGRAPHS ....................................................................................................................... 15

EXHIBIT B - TEST SETUP PHOTOGRAPHS ....................................................................................................... 27 CONDUCTED EMISSIONS - FRONT SIDE ...................................................................................................................... 27 CONDUCTED EMISSIONS - REAR SIDE ........................................................................................................................ 27 RADIATED DISTURBANCES FRONT SIDE (BELOW 1GHZ) ........................................................................................... 28 RADIATED DISTURBANCES REAR SIDE (BELOW 1 GHZ) ............................................................................................ 28

PRODUCT SIMILARITY DECLARATION LETTER .......................................................................................... 29

FCC Part 15B Page 2 of 29

Page 4: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1 REPORT REVISION

Report Number Report Date Contents RSHA200311002-00A 2020-03-24 Original Report

RSHA200311002-00AM1 2020-03-30 Update Report Number The items used black in italics in the report was revised due to typo.

FCC Part 15B Page 3 of 29

Page 5: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1 GENERAL INFORMATION Product Description for Equipment under Test (EUT)

Applicant Elitech Technology, Inc. Test Model LKC-1000S+

Product Air Quality Detector Rate Voltage DC 5.0V

Note: The product’s series model number: LKC-1000E, LKC-1000S.The difference between them was explained in the attached declaration letter. *All measurement and test data in this report was gathered from production sample serial number: 20200311002. (Assigned by BACL, Kunshan). The EUT supplied by the applicant was received on 2020-03-11. Objective This report is prepared on behalf of Elitech Technology, Inc. in accordance with Part 2-Subpart J, and Part 15-Subparts A and B of the Federal Communication Commission’s rules. The objective of the manufacturer is to determine the compliance of EUT with FCC Part 15, Class B device. Related Submittal(s)/Grant(s) No related submittal(s). Test Methodology All measurements contained in this report were conducted with ANSI C63.4-2014, American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the range of 9 kHz to 40 GHz. All radiated and conducted emissions measurement was performed at Bay Area Compliance Laboratories Corp. (Kunshan). The radiated testing was performed at an antenna-to-EUT distance of 3 meters. Test Facility The test site used by Bay Area Compliance Laboratories Corp. (Kunshan) to collect test data is located on the No.248 Chenghu Road, Kunshan,Jiangsu province, China. Bay Area Compliance Laboratories Corp. (Kunshan) Lab is accredited to ISO/IEC 17025 by A2LA (Lab code: 4323.01) and the FCC designation No. CN1185 under the FCC KDB 974614 D01 and CAB identifier CN0004 under the ISED requirement. The facility also complies with the radiated and AC line conducted test site criteria set forth in ANSI C63.4-2014.

FCC Part 15B Page 4 of 29

Page 6: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1 SYSTEM TEST CONFIGURATION Justification The system was configured for testing in a typical fashion (as normally used by a typical user). Test mode: Charging & Normal working EUT Exercise Software No exercise software was used to test. Special Accessories No special accessory was used. Equipment Modifications No modification was made to the EUT tested. Support Equipment List and Details

Manufacturer Description Model Serial Number

DongGuan AoHai Power Technology Co.,Ltd Adapter A18A-050100U-US2 /

External I/O Cable

Cable Description Length (m) From/Port To

Power Cable 1.0 EUT Adapter

Power Cable 1.0 Adapter AC Source

FCC Part 15B Page 5 of 29

Page 7: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1 Block Diagram of Radiated Test Setup

EUT

Adapter

AC Source

Non-Conductive Table 80cm Above Ground Plane 1.5m*1.0m*0.8m Table

FCC Part 15B Page 6 of 29

Page 8: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1 SUMMARY OF TEST RESULTS

FCC Rules Description of Test Results

§15.107 Conducted Emissions Compliant

§15.109 Radiated Emissions Compliant

FCC Part 15B Page 7 of 29

Page 9: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1

FCC §15.107 –CONDUCTED EMISSIONS Applicable Standard According to FCC§15.107 Measurement Uncertainty Input quantities to be considered for conducted disturbance measurements maybe receiver reading, attenuation of the connection between LISN and receiver, LISN voltage division factor, LISN VDF frequency interpolation and receiver related input quantities, etc.

Item Measurement Uncertainty Ucispr

AMN 150kHz~30MHz 3.19 dB 3.4 dB Otherwise required by the applicant or Product Regulations, Decision Rule in this report did not consider the uncertainty. EUT Setup

The measurement procedure of EUT setup is according with ANSI C63.4-2014. The related limit was specified in FCC Part 15.107 Class B. The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the middle. The spacing between the peripherals was 10 cm.

FCC Part 15B Page 8 of 29

Page 10: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1 EMI Test Receiver Setup The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz During the conducted emission test, the EMI test receiver was set with the following configurations:

Frequency Range IF B/W 150 kHz – 30 MHz 9 kHz

Test Procedure During the conducted emission test, the EUT was connected to the outlet of the LISN. Maximizing procedure was performed on the six (6) highest emissions of the EUT. All final data was recorded in the Quasi-peak and average detection mode. Test Equipment List and Details

Manufacturer Description Model Serial Number Calibration Date

Calibration Due Date

Rohde & Schwarz EMI Test receiver ESR 1316.3003K03-102454-Qd 2019-06-25 2020-06-24

Rohde & Schwarz LISN ENV216 3560655016 2019-12-14 2020-12-13

Audix Test Software e3 V9 -- --

MICRO-COAX Coaxial Cable Cable-15 015 2019-08-15 2020-08-14 * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Kunshan) attests that all calibrations have been performed in accordance to requirements that traceable to National Primary Standards and International System of Units (SI). Factor & Over Limit Calculation The Factor is calculated by adding LISN VDF (Voltage Division Factor), Cable Loss and Transient Limiter Attenuation. The basic equation is as follows:

Factor (dB) = LISN VDF (dB) + Cable Loss (dB) + Transient Limiter Attenuation (dB) The “Over Limit” column of the following data tables indicates the degree of compliance with the applicable limit. For example, an Over Limit of 7 dB means the emission is 7 dB above the limit. The equation for Over Limit calculation is as follows: Over Limit (dB) = Read level (dBμV) + Factor (dB) - Limit (dBμV)

FCC Part 15B Page 9 of 29

Page 11: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1 Test Data Environmental Conditions

Temperature: 26℃

Relative Humidity: 50 %

ATM Pressure: 101.0 kPa The testing was performed by Tina Li on 2020-03-18. Test Mode1 Line:

FCC Part 15B Page 10 of 29

Page 12: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1 Neutral:

FCC Part 15B Page 11 of 29

Page 13: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1

FCC §15.109 - RADIATED EMISSIONS Applicable Standard FCC §15.109 Measurement Uncertainty All measurements involve certain levels of uncertainties, especially in field of EMC. The factors contributing to uncertainties are spectrum analyzer, cable loss, antenna factor calibration, antenna directivity, antenna factor variation with height, antenna phase center variation, antenna factor frequency interpolation, measurement distance variation, site imperfections, mismatch (average), and system repeatability.

Item Measurement Uncertainty Ucispr

Radiated Emission 30MHz~1GHz 6.11dB 6.3 dB Otherwise required by the applicant or Product Regulations, Decision Rule in this report did not consider the uncertainty. EUT Setup Below 1GHz:

The radiated emission tests were performed in the 3 meters chamber test site, using the setup accordance with the ANSI C63.4-2014. The specification used was the FCC Part 15.109 Class B limits. The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the middle. The spacing between the peripherals was 10 cm.

FCC Part 15B Page 12 of 29

Page 14: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1 EMI Test Receiver Setup The system was investigated from 30 MHz to 1 GHz. During the radiated emission test, the EMI test receiver was set with the following configurations:

Frequency Range RBW Video B/W IF B/W Detector

30MHz – 1000 MHz 120 kHz 300 kHz 120kHz QP Test Procedure Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all installation combinations. All data was recorded in the Quasi-peak detector mode from 30 MHz to 1 GHz. Test Equipment List and Details

Manufacturer Description Model Serial Number Calibration Date

Calibration Due Date

Sonoma Instrument Amplifier 310N 185700 2019-08-14 2020-08-13

Rohde & Schwarz EMI Test Receiver ESCI 100195 2019-11-12 2020-11-11

Sunol Sciences Broadband Antenna JB3 A090413-1 2019-12-26 2022-12-25

Champrotek Chamber Chamber A T-KSEMC049 - -

R&S Auto test Software EMC32 100361 - -

MICRO-COAX Coaxial Cable Cable-8 008 2019-08-15 2020-08-14

MICRO-COAX Coaxial Cable Cable-9 009 2019-08-15 2020-08-14

MICRO-COAX Coaxial Cable Cable-10 010 2019-08-15 2020-08-14 * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Kunshan) attests that all calibrations have been performed in accordance to requirements that traceable to National Primary Standards and International System of Units (SI). Corrected Amplitude & Margin Calculation The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the Amplifier Gain from the Meter Reading. The basic equation is as follows:

Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain The “Margin” column of the following data tables indicates the degree of compliance with the applicable limit. For example, a margin of 7 dB means the emission is 7 dB below the limit. The equation for margin calculation is as follows:

Margin = Limit – Corrected Amplitude

FCC Part 15B Page 13 of 29

Page 15: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1 Test Data Environmental Conditions

Temperature: 26 ℃ Relative Humidity: 50%

ATM Pressure: 101.0 kPa The testing was performed by Tina Li on 2020-03-18. Test mode1 1)30MHz ~ 1GHz

0

20

40

60

80

30M 50 60 80 100M 200 300 400 500 800 1G

Leve

l in

dBμV

/

Frequency in Hz

Frequency (MHz)

QuasiPeak (dBμV/m)

Limit (dBμV/m)

Margin (dB)

Height (cm) Pol Azimuth

(deg) Corr.

(dB/m)

30.762915 28.59 40.00 11.41 100.0 V 226.0 -4.4

98.018650 25.57 43.50 17.93 200.0 V 305.0 -15.4

106.488350 29.05 43.50 14.45 200.0 V 163.0 -13.7

144.259900 40.30 43.50 3.20 100.0 V 143.0 -12.1

185.053350 38.71 43.50 4.79 100.0 V 117.0 -13.3

282.083550 38.18 46.00 7.82 100.0 H 84.0 -11.1

Lev

el in

dBμ

V/m

FCC Part 15B Page 14 of 29

Page 16: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1 EXHIBIT A - EUT PHOTOGRAPHS

FCC Part 15B Page 15 of 29

Page 17: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1

FCC Part 15B Page 16 of 29

Page 18: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1

FCC Part 15B Page 17 of 29

Page 19: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1

FCC Part 15B Page 18 of 29

Page 20: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1

FCC Part 15B Page 19 of 29

Page 21: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1

FCC Part 15B Page 20 of 29

Page 22: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1

FCC Part 15B Page 21 of 29

Page 23: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1

FCC Part 15B Page 22 of 29

Page 24: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1

FCC Part 15B Page 23 of 29

Page 25: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1

FCC Part 15B Page 24 of 29

Page 26: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1

FCC Part 15B Page 25 of 29

Page 27: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1

FCC Part 15B Page 26 of 29

Page 28: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1 EXHIBIT B - TEST SETUP PHOTOGRAPHS

Conducted Emissions - Front Side

Conducted Emissions - Rear Side

FCC Part 15B Page 27 of 29

Page 29: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1

Radiated Disturbances Front Side (Below 1GHz)

Radiated Disturbances Rear Side (Below 1 GHz)

FCC Part 15B Page 28 of 29

Page 30: CERTIFICATE - m.media-amazon.com

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200311002-00AM1 PRODUCT SIMILARITY DECLARATION LETTER

*****END OF REPORT*****

FCC Part 15B Page 29 of 29