CERTIFICATE OF COMPLIANCE Certificate Number 20130104-E135493 Report Reference E135493-A14-UL Issue Date 2013-JANUARY-04 William R. Carney, Director, North American Certification Programs UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at www.ul.com/contactus Page 1 of 1 Issued to: VICOR CORP 25 FRONTAGE RD ANDOVER MA 01810 This is to certify that representative samples of COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT. DC/DC Converter IBaaaEfffGwwxy-zz Intermediate Bus Converter (IBC) Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: UL 60950-1 and CSA C22.2 No. 60950-1-07, (Information Technology Equipment - Safety - Part 1: General Requirements). Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Recognized Component Marks for the U.S. and Canada should be considered as being covered by UL's Recognition and Follow-Up Service and meeting the appropriate U.S. and Canadian requirements. The UL Recognized Component Mark for the U.S. generally consists of the manufacturer’s identification and catalog number, model number or other product designation as specified under “Marking” for the particular Recognition as published in the appropriate UL Directory. As a supplementary means of identifying products that have been produced under UL’s Component Recognition Program, UL’s Recognized Component Mark: , may be used in conjunction with the required Recognized Marks. The Recognized Component Mark is required when specified in the UL Directory preceding the recognitions or under “Markings” for the individual recognitions. The UL Recognized Component Mark for Canada consists of the UL Recognized Mark for Canada: and the manufacturer’s identification and catalog number, model number or other product designation as specified under “Marking” for the particular Recognition as published in the appropriate UL Directory. Recognized components are incomplete in certain constructional features or restricted in performance capabilities and are intended for use as components of complete equipment submitted for investigation rather than for direct separate installation in the field. The final acceptance of the component is dependent upon its installation and use in complete equipment submitted to UL LLC. Look for the UL Recognized Component Mark on the product.
Transcript
Page 1: CERTIFICATE OF COMPLIANCE - Vicor Corporation · CERTIFICATE OF COMPLIANCE Certificate Number -E135493 Report Reference -A14 UL Issue Date -JANUARY 04 William R. Carney, Director,

C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20130104-E135493

Report Reference E135493-A14-UL

Issue Date 2013-JANUARY-04

William R. Carney, Director, North American Certification Programs UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at www.ul.com/contactus

Page 1 of 1

Issued to: VICOR CORP

25 FRONTAGE RD

ANDOVER MA 01810

This is to certify that

representative samples of

COMPONENT - POWER SUPPLIES, INFORMATION

TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL

BUSINESS EQUIPMENT.

DC/DC Converter

IBaaaEfffGwwxy-zz

Intermediate Bus Converter (IBC)

Have been investigated by UL in accordance with the

Standard(s) indicated on this Certificate.

Standard(s) for Safety: UL 60950-1 and CSA C22.2 No. 60950-1-07, (Information

Technology Equipment - Safety - Part 1: General

Requirements).

Additional Information: See the UL Online Certifications Directory at

www.ul.com/database for additional information

Only those products bearing the UL Recognized Component Marks for the U.S. and Canada should be considered as being covered by UL's Recognition and Follow-Up Service and meeting the appropriate U.S. and Canadian requirements.

The UL Recognized Component Mark for the U.S. generally consists of the manufacturer’s identification and catalog number, model number or other product designation as specified under “Marking” for the particular Recognition as published in the appropriate UL Directory. As a supplementary means of identifying products that have been produced under UL’s Component Recognition Program, UL’s Recognized Component Mark: , may be used in conjunction with the required Recognized Marks. The Recognized Component Mark is required when specified in the UL Directory preceding the recognitions or under “Markings” for the individual recognitions. The UL Recognized Component Mark for Canada consists of the UL Recognized Mark for Canada: and the manufacturer’s identification and catalog number, model number or other product designation as specified under “Marking” for the particular Recognition as published in the appropriate UL Directory.

Recognized components are incomplete in certain constructional features or restricted in performance capabilities and are intended for use as components of complete equipment submitted for investigation rather than for direct separate installation in the field. The final acceptance of the component is dependent upon its installation and use in complete equipment submitted to UL LLC. Look for the UL Recognized Component Mark on the product.

Page 2: CERTIFICATE OF COMPLIANCE - Vicor Corporation · CERTIFICATE OF COMPLIANCE Certificate Number -E135493 Report Reference -A14 UL Issue Date -JANUARY 04 William R. Carney, Director,

Issue Date: 2011-03-07 Page 1 of 6 Report Reference # E135493-A14-UL

2013-01-04

Copyright © 2013

UL TEST REPORT AND PROCEDURE

Standard: UL 60950-1, 2nd Edition, 2011-12-19 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information Technology Equipment - Safety - Part 1: General Requirements)

Certification Type: Component Recognition

CCN: QQGQ2, QQGQ8 (Power Supplies for Information Technology Equipment Including Electrical Business Equipment)

Product: DC/DC Converter

Model: IBaaaEfffGwwxy-zz Intermediate Bus Converter (IBC) See Miscellaneous Enclosure for model matrix

Rating: Input: 48Vdc Output Voltage: 9.6 or 12Vdc max Output Power 62Amax or 570Wmax See Miscellaneous Enclosure for model details.

Applicant Name and Address: VICOR CORP 25 FRONTAGE RD ANDOVER MA 01810 UNITED STATES

This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL.

Prepared by: Gerard Soprych Reviewed by: Daniel Pirozzi

Page 3: CERTIFICATE OF COMPLIANCE - Vicor Corporation · CERTIFICATE OF COMPLIANCE Certificate Number -E135493 Report Reference -A14 UL Issue Date -JANUARY 04 William R. Carney, Director,

Issue Date: 2011-03-07 Page 2 of 6 Report Reference # E135493-A14-UL

2013-01-04

Supporting Documentation

The following documents located at the beginning of this Procedure supplement the requirements of this Test Report:

A. Authorization - The Authorization page may include additional Factory Identification Code markings.

B. Generic Inspection Instructions -

i. Part AC details important information which may be applicable to products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report.

ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report.

iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.

Product Description

The VI Brick IBC 1/8th Brick family of DC-DC converters are designed for building-in. The IBC converters provide Basic Insulation from Input to Output. The IB048 models provide a dielectric withstand rating of 1500Vdc while the IB050 and IB054 provide a dielectric withstand rating of 2250Vdc. The IB054 models are IB050 variants that can withstand input transients of 75Vdc for 100mS.

Model Differences

See Miscellaneous Enclosure for model nomenclature.

Page 4: CERTIFICATE OF COMPLIANCE - Vicor Corporation · CERTIFICATE OF COMPLIANCE Certificate Number -E135493 Report Reference -A14 UL Issue Date -JANUARY 04 William R. Carney, Director,

Issue Date: 2011-03-07 Page 3 of 6 Report Reference # E135493-A14-UL

2013-01-04

Technical Considerations

Equipment mobility : for building-in

Connection to the mains : -

Operating condition : continuous

Access location : building-in

Over voltage category (OVC) : OVC II

Mains supply tolerance (%) or absolute mains supply values : N/A

Tested for IT power systems : No

IT testing, phase-phase voltage (V) : -

Class of equipment : Not classified

Considered current rating of protective device as part of the building installation (A) : -

Pollution degree (PD) : PD 2

IP protection class : IP X0

Altitude of operation (m) : 2000

Altitude of test laboratory (m) : 150

Mass of equipment (kg) : 0.02kg

The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by the manufacturer’s specification of: max. allowed PCB temperature of 130°C under normal operating conditions

Page 5: CERTIFICATE OF COMPLIANCE - Vicor Corporation · CERTIFICATE OF COMPLIANCE Certificate Number -E135493 Report Reference -A14 UL Issue Date -JANUARY 04 William R. Carney, Director,

Issue Date: 2011-03-07 Page 4 of 6 Report Reference # E135493-A14-UL

2013-01-04

Engineering Conditions of Acceptability

For use only in or with complete equipment where the acceptability of the combination is determined by UL LLC. When installed in an end-product, consideration must be given to the following:

Input Voltage: Both a nominal input voltage and an input voltage range are specified. Operation over the entire range was evaluated. The output voltage is a fixed turns ratio of the input voltage.

Max Output: The IBC has both a maximum current and a maximum power rating. The end use application shall not exceed the lower limit of either maximum power or maximum current.

Max Temperature: The maximum allowable PCB temperature is 130°C under normal operation and should be evaluated in the end use product.

Fusing Requirements: The IBCs were evaluated with an external fast acting fuse. Littelfuse Nano2 rated 30A or less or BEL Fuse SSQ Series rated 15A or less.

The IB048 models provide 1500Vdc of isolation from input to output.

The IB050 and IB054 models provide 2250Vdc of isolation from input to output.

The output is separated from the input by Basic Insulation.

The following secondary output circuits are SELV: All

The following secondary output circuits are at hazardous energy levels: All

The power supply terminals and/or connectors are: Not investigated for field wiring

The investigated Pollution Degree is: 2

Proper bonding to the end-product main protective earthing termination is: Required

An investigation of the protective bonding terminals has: Not been conducted

The following end-product enclosures are required: Mechanical, Fire, Electrical

Additional Information

N/A

Markings and instructions

Clause Title Marking or Instruction Details

1.7.1 Power rating - Company identification

Listee's or Recognized company's name, Trade Name, Trademark or File Number

1.7.1 Power rating - Model

Model Number

Special Instructions to UL Representative

N/A

Page 6: CERTIFICATE OF COMPLIANCE - Vicor Corporation · CERTIFICATE OF COMPLIANCE Certificate Number -E135493 Report Reference -A14 UL Issue Date -JANUARY 04 William R. Carney, Director,

File E135493 Vol. X4 Sec. A14 MIS-01 Issued: 2011-03-07