Challenger Cloud LED TwinLinear LED Surface Luminaires
The information given on these sheets is typical of the product depicted; it must not be interpreted as a guarantee of individual product performance and/or characteristics.We reserve the right to alter specifications and designs without prior notice. All measurements are in millimetres (mm).
Challenger Cloud LED Twin 2 x 24W
180° 150°150°
120°120°
90°90°
0° 30°30°
60°60°
cd / 1000 lmC0 / C180 C90 / C270
100
50
150
200
250
MIC System Available
Trunking Mounting Clips Stainless Steel Clips
W
D
FCL
Low energy efficiency
High energy efficiency
Challenger Cloud LED Twin is an IP65 linear LED non corrosive luminaire that is available in a high output or a high efficiency version, both of which deliver significant energy savings. It is available with an optional microwave Manual Intelligent Control (MIC) for enhanced energy savings and is ideal for environments where dust, dirt and moisture prevail; for example in manufacturing premises, kitchens, car parks, stairwells, concourses, cold stores and boiler rooms etc.
Features:• IP65 (dust tight & water jet proof)• IK10 (10 joule) shock resistance• Corrosion resistant• Energy efficient Osram LEDs• High efficiency version: – LED power: 1270mm – 17W, 1570mm – 24W – High lumen output: up to 147 lumens per watt • High output version: – LED power: 1270mm – 25W, 1570mm – 36W – High lumen output: up to 138 lumens per watt• Optimum single bin LEDs with a 3 MacAdam ellipse tolerance• Average 50,000 hrs LED life – maintenance free• LED colour temperature: 4000K (cool)• Quick release clip on lens• Wall or ceiling mounting
Options:• Available with an integrated microwave Manual Intelligent Control (MIC)• Integral 3hr maintained emergency• Single or twin version available• Stainless steel lens clips• Trunking mounting clips• 20mm through wiring provision
Material:• Body: polycarbonate • Lens: polycarbonate
Finish:• Body: grey• Lens: cloud or prismatic
Spares:All components are available from Lamps and Lighting’s UK manufacturing facility.
These luminaires are designed to comply with EN 60598-1 (BS 4533:101)Emergency EN 60598.2.22 (BS 4533:102.22)
High Efficiency
2 x LED 17W 4000K (cool) - 4631lm
2 x LED 24W 4000K (cool) - 6428 lm
High Output
2 x LED 25W 4000K (cool) - 6300 lm
2 x LED 36W 4000K (cool) - 8878 lm
Accessories
Stainless steel clips – (8pk) 1270mm
Stainless steel clips – (10pk) 1570mm
Trunking mounting clips – (2pk)
MIC 1
LSCC 2414
LSCC 2514
LSCC 2424
LSCC 2524
FSCX 8/SS
FSCX 10/SS
FSCXA/TM
E3-LSCC 2414
E3-LSCC 2514
E3-LSCC 2424
E3-LSCC 2524
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
Standard Emergency MIC 2 MIC 3
MIC Compatibility (See pages 2 & 3)Ordering CodeChallenger Cloud LED Twin
Dimensions (mm)
2 x LED 17W
2 x LED 24W
2 x LED 25W
2 x LED 36W
L
1270
1570
1270
1570
W
160
160
160
160
D
106
106
106
106
FC
900
900
900
900
Ordering Example:
LSCC 2414/MIC3
LSCC 2 4 1 4 /MIC3
Challenger Cloud LED Twin Length Wattage LED Colour Temperature Control
t: 01282 448666f: 01282 417703
www.lampslighting.co.uk MICThe Manual Intelligent Control (MIC) system features a range of advanced sensor technology controls offering the ultimate in energy saving and carbon reduction. Significant energy savings can be achieved with a MIC system that dynamically manages lamp power according to the instantaneous lighting requirement. It ensures that the right level of light appears at the right place only when required, this preventing unnecessary energy consumption and potentially reducing maintenance costs. The MIC system has been installed in over 3000 BT telephone exchanges with confirmed energy savings in excess of 70%.
There are three types of Manual Intelligent Control: MIC1, MIC2 and MIC3, available as a master (sensor incorporated) or a slave (controlled by master), to suit different requirements and budgets. The manual intelligent controls are programmed manually by a dip switch to switch on and off automatically to maximise cost savings.
MIC 1
MIC 2
MIC 3
MIC 1 is a versatile and cost-effective OFF–ON–OFF energy saving control unit.
MIC 2 offers all the benefits of the MIC 1 but with a DIM–ON–DIM function. MIC 2 is an ideal control for reducing energy consumptions whilst still providing some level of illumination for extra safety.
MIC 3 is the most flexible energy saving manual control with an OFF–ON–DIM–OFF function, permitting full light management and maximum energy saving.
OFF
DIM
OFF ON DIM OFF
ON
ON
OFF
DIM
Absence – luminaires areswitched off.
Absence – luminaires areon at a courtesy preset dimmed level. Approximately 20% output and 1/3 total power.
Absence – luminaires are switched off.
Occupancy detected – luminaires illuminate at full output.
After a preset time of absence, luminaires dim to the courtesy preset dimmed level. Approximately 20% output and 1/3 total power
After continued absence over a preset time, luminaires switch off completely. If required, the ‘off’ function can be disabled to operate as a MIC 2
Occupancy detected –luminaires illuminate at full output unless there is sufficient daylight and the lux level setting overides it.
Occupancy detected –luminaires illuminate at full output.
Absence – after a preset time, luminaires switch off completely.
Absence – after a preset time of absence, luminaires return to the courtesy preset dimmed level.
Suffix LuminaireOrdering Code
Suffix LuminaireOrdering Code
Suffix LuminaireOrdering Code
Master:
/MIC1
Slave:
/MIC1S
Example –Challenger LED 1270mm with integrated MIC1 slave system: LSCC 2414/MIC1/s
Master:
/MIC2
Slave:
/MIC2S
Example –Challenger LED 1570mm with integrated MIC2 master system: LSCC 2514/MIC2
Master:
/MIC3
Slave:
/MIC3S
Example –Emergency Challenger LED 1270mm slave with integrated MIC3 master system: E3-LSCC 2414/MIC3
MIC 1
DIP Switch
0–2000 lux
N/A
5–30 mins
2–10 metres
N/A
360°
600W
Operating function
Lux level adjustment
Time adjustment to courtesy preset dimmed level
Time adjustment to switch off completely
Sensitivity (range) adjustment
Dimming level (iLite ballast/driver)
Detection angle
Sensor maximum load (inductive)
MIC 2
DIP Switch
N/A
5–30 mins
N/A
2–10 metres
10/25/50%
360°
600W
MIC 3
DIP Switch
N/A
5–30 mins
10–30 mins
1–6 metres
10/25/50%
360°
600W
MIC Operating Functions and Features
t: 01282 448666f: 01282 417703
www.lampslighting.co.uk MIC
Setting 1 =2metres Setting 2 = 5 metres Setting 3 =10metres
0
3.5
10 08 6 4 2 2 4 6 8 10
Detection area (metres)
Mou
ntin
g H
eigh
t (m
etre
s)
0
Sett ing 1 = 1 metre S ett ing 2 = 3 me tres S ett ing 3 = 6 me tres
0
8
10 08 6 4 2 2 4 6 8 10
Detection area (metres)
Mou
ntin
g H
eigh
t (m
etre
s)
0
Master Master Master Master
Master Master Master Master
Master Master Master Master
Master Slave Master Slave
Master Slave Master Slave
Master Master Master Master
Master Master Master Master
Master Master Master Master
Master Slave Master Slave
Master Slave Master Slave
OnKey: Off
Typical Installation Options
The MIC system offers complete flexibility as it can be easily installed into existing or new lighting schemes and requires no complex programming. The following wiring options are available:
Option One
The masters are all working independently for maximum energy efficiency to create a cascade effect. This is ideal for a retrofit installation.
Option Two
The master is working in conjunction with a slave to illuminate a specific zone. The master will control the slaves.
Option Three
The masters and the slaves are working in conjunction to illuminate a larger area.
Option Four
The masters are working together for maximum energy efficiency and sensitivity in a zoned area.
Option Five
All masters are working together for maximum sensitivity and control of a complete area.
Detection Area
MIC 1 & 2 MIC 3