+ All Categories
Home > Documents > Chandelier Assembly Instructions - Murano Glass Chandeliers€¦ · 16. A B B B B B B B B B A FIXED...

Chandelier Assembly Instructions - Murano Glass Chandeliers€¦ · 16. A B B B B B B B B B A FIXED...

Date post: 07-Nov-2020
Category:
Upload: others
View: 3 times
Download: 0 times
Share this document with a friend
1
16. A A B B B B B B B B B A FIXED LUMINAIRE Rated power: Max 40W Type lamp: E14 Rated voltage: 230V Protection degree: IP20 Frequency: 50Hz Safety class protection: Classe I WARNING: 1- Read these instructions carefully before beginning to fit the lighting unit. 2- To preserve with care this sheet for every ulterior consultation. 3- This electrical unit must be installed by qualified personnel. 4- The following the assembly technical designs are generic (do not represent the specific article). The manufacturer in not responsible if the fixtures are not installed in according to these instructions and to local safety standards. For glass component Neutral Ground Line Assembly connector instructions: a) Predispose a hook appropriated to the ceiling where to be able to couple the luminaire; b) Insert and lock the EARTH cable in the clip marked with the earth symbol ; c) Insert and lock the LINE cable in the clip marked with the line symbol “L”; d) Insert and lock the NEUTRAL cable in the clip marked with the neutral symbol “N”; e) Move the canopy to touch the ceiling and to screw the screw. Maintenance instruction: WARNING: THE LAMP IS VERY HOT, DON’T TOUCH TILL WHEN IT’S COLD For lamp substitution: a) Disconnect main power; b) Turn the lamp and take one with the same technical characteristics; c) Connect main power and turn on the switch for power on the luminaire; Insert the wires of lampholder to male faston marked with label (L) e (N) A) Holes where must be inserted the arms, locked by screws. B) Holes where must be inserted decorative components (11, 12, 13) 18. Arm 1 Arm 2 Arm 3 1. 2. 3. 4. 5. 6. 7. 9. 10. 11. 13. 12. 15. 14. 16. 17. 18. 19. 20. 21. Supplied assembled Assembly legend: 1. Glass canopy 2. Metal canopy to hide the wires 3. Ring-brake with pressure screw and ring, to allow the glass canopy to smoothly adhere to the ceiling 4. Chain (length can vary), the last ring must be hooked to (5.) and closed with pliers 5. Ring by which the chandelier 6. Tiges (variable length) threaded top and bottom 7. Glass bowl 8. Glass sphere 9. Glass body part 10. Two plastic washers and knurled metal kasher to fix the metal plate 11. Upward glass leaver with rings at the bottom end to allow the glass to hang straight from the metal plate 12. Flower (same as 11.) 13. Downward leaver (same as 11.) 14. Arm (same as 11.) 15. Glass shade in which must be inserted the socket 16. Metal plate with hole where must be inserted the arms, the downward and upward leaves and the flowers 17. Aluminum cover for the metal plate 18. Kasher to block the metal plate 19. Glass botton bowl 20. Glass ball 21. Glass finial
Transcript
Page 1: Chandelier Assembly Instructions - Murano Glass Chandeliers€¦ · 16. A B B B B B B B B B A FIXED LUMINAIRE Rated power: Max 40W Type lamp: E14 Rated voltage: 230V Protection degree:

16.

A A

B B B B

B

BB

B

B

A

FIXED LUMINAIRE

Rated power: Max 40W Type lamp: E14 Rated voltage: 230V Protection degree: IP20 Frequency: 50Hz Safety class protection: Classe I WARNING: 1- Read these instructions carefully before beginning to fit the lighting unit. 2- To preserve with care this sheet for every ulterior consultation. 3- This electrical unit must be installed by qualified personnel. 4- The following the assembly technical designs are generic (do not represent the specific article). The manufacturer in not responsible if the fixtures are not installed in according to these instructions and to local safety standards.

For glass component

Neutral

Ground

Line

Assembly connector instructions:

a) Predispose a hook appropriated to the ceiling where to be able to couple the luminaire;

b) Insert and lock the EARTH cable in the clip marked with the earth symbol

;c) Insert and lock the LINE cable in the

clip marked with the line symbol “L”; d) Insert and lock the NEUTRAL cable

in the clip marked with the neutral symbol “N”;

e) Move the canopy to touch the ceiling and to screw the screw.

Maintenance instruction:

WARNING: THE LAMP IS VERY HOT, DON’T TOUCH TILL WHEN IT’S COLD For lamp substitution:

a) Disconnect main power; b) Turn the lamp and take one with the

same technical characteristics; c) Connect main power and turn on the

switch for power on the luminaire;

Insert the wires of lampholder to male faston marked with label (L) e (N)

A) Holes where must be inserted the arms, locked by screws.

B) Holes where must be inserted decorative components (11, 12, 13)

18.

Arm 1

Arm 2

Arm 3

1.

2.

3.

4.

5.

6.

7.

9.

10.

11.

13.

12.

15.

14.

16.

17. 18.

19.

20.

21.

Suppliedassembled

Assembly legend:

1. Glass canopy 2. Metal canopy to hide the wires 3. Ring-brake with pressure screw and

ring, to allow the glass canopy to smoothly adhere to the ceiling

4. Chain (length can vary), the last ring must be hooked to (5.) and closed with pliers

5. Ring by which the chandelier 6. Tiges (variable length) threaded top and

bottom 7. Glass bowl 8. Glass sphere 9. Glass body part 10. Two plastic washers and knurled metal

kasher to fix the metal plate 11. Upward glass leaver with rings at the

bottom end to allow the glass to hang straight from the metal plate

12. Flower (same as 11.) 13. Downward leaver (same as 11.) 14. Arm (same as 11.) 15. Glass shade in which must be inserted

the socket 16. Metal plate with hole where must be

inserted the arms, the downward and upward leaves and the flowers

17. Aluminum cover for the metal plate 18. Kasher to block the metal plate 19. Glass botton bowl 20. Glass ball 21. Glass finial

Recommended