+ All Categories
Home > Documents > characterizing in innovatint labmy.innovatint.com/data/download/public-files/... · 3/1/2017  ·...

characterizing in innovatint labmy.innovatint.com/data/download/public-files/... · 3/1/2017  ·...

Date post: 23-Aug-2020
Category:
Upload: others
View: 1 times
Download: 0 times
Share this document with a friend
17
2017 Innovatint version 3 Characterizing in Innovatint Lab Date: 01-03-2017
Transcript
Page 1: characterizing in innovatint labmy.innovatint.com/data/download/public-files/... · 3/1/2017  · 201 characterizing in innovatint lab 7 Innovatint version 3 Characterizing in Innovatint

characterizing in innovatint lab

2017

Innovatint version 3 Characterizing in Innovatint Lab

Date: 01-03-2017

Page 2: characterizing in innovatint labmy.innovatint.com/data/download/public-files/... · 3/1/2017  · 201 characterizing in innovatint lab 7 Innovatint version 3 Characterizing in Innovatint

CHARACTERIZING IN INNOVATINT LAB

1 | P a g e

Table of contents 1. Characterizing bases in existing database with same bootstrap components 2 or other already characterized black/white colorants 2. Characterizing bases in existing database but other bootstrap components 10 3. Characterizing colorants in existing database with or without different 15 bootstrap components 4. Start from scratch 16

Page 3: characterizing in innovatint labmy.innovatint.com/data/download/public-files/... · 3/1/2017  · 201 characterizing in innovatint lab 7 Innovatint version 3 Characterizing in Innovatint

CHARACTERIZING IN INNOVATINT LAB

2 | P a g e

1. Characterizing bases in existing database with same bootstrap

components or with already characterized other black/white colorants

Normally when a database is send out by Chromaflo Technologies it will hold characterized colorants

and standard Chromaflo Technologies bases. The mixtures used to characterize these components are

not visible anymore, but the K/S values can be used.

In some occasions the database will also hold all the mixtures that have been used to perform the

characterization. These should not be altered as they have been checked on accuracy.

When starting to build a database starting from a standard Chromaflo Technologies database you will

see that the bootstrap components are set for a Chromaflo Technologies standard product and base.

Page 4: characterizing in innovatint labmy.innovatint.com/data/download/public-files/... · 3/1/2017  · 201 characterizing in innovatint lab 7 Innovatint version 3 Characterizing in Innovatint

CHARACTERIZING IN INNOVATINT LAB

3 | P a g e

As you probably will not be using that combination of product and base it is logical that you delete the

product out of the system. This is not a problem as the product and the base characterization are not

linked to each other. The characterized components will remain in the database even when they are

removed in the products holding them.

When you would remove the base characterizer component from the set or you change it to another

component you would get a message:

When clicking “Yes” the “Base characterizer” will be empty or change to the new selected component.

Also, when you would de-select the component and it is not present anymore in any products it will also

disappear from the components list.

Page 5: characterizing in innovatint labmy.innovatint.com/data/download/public-files/... · 3/1/2017  · 201 characterizing in innovatint lab 7 Innovatint version 3 Characterizing in Innovatint

CHARACTERIZING IN INNOVATINT LAB

4 | P a g e

As a consequence of deleting the component used for the characterization all mixtures using that

component are deleted. The K/S values will still be there and can be used for matching, but you cannot

change anything anymore in the mixtures as they are taken out.

The same thing applies when changing the “White characterizer” or “Black characterizer”. Probably you

will need to do this as the characterization of Chromaflo Technologies is always done with the same

colorants and bases, some of which are not in the colorant system you are using.

NOTE: when changing a white or black bootstrap component you will see in the “Colorants” section the

colorants from the original bootstrap components also coming up. You can delete them from the set by

de-selecting them.

Page 6: characterizing in innovatint labmy.innovatint.com/data/download/public-files/... · 3/1/2017  · 201 characterizing in innovatint lab 7 Innovatint version 3 Characterizing in Innovatint

CHARACTERIZING IN INNOVATINT LAB

5 | P a g e

When the selection of the characterization components is correct you can start characterizing the new

bases. When you have made a new product/base you still need to add them into the set. Do this by

clicking on “Add component(s)”.

Page 7: characterizing in innovatint labmy.innovatint.com/data/download/public-files/... · 3/1/2017  · 201 characterizing in innovatint lab 7 Innovatint version 3 Characterizing in Innovatint

CHARACTERIZING IN INNOVATINT LAB

6 | P a g e

A new screen will come up:

As mentioned before the components in a set do not necessarily be in a product or colorant system. It is

possible to add a new component directly without actually using it in the rest of the database. Normally

you would use a component that actually has been configured already. For this click on “Existing

components”. Here you will see an overview of non-characterized components that are already used in

the database.

Page 8: characterizing in innovatint labmy.innovatint.com/data/download/public-files/... · 3/1/2017  · 201 characterizing in innovatint lab 7 Innovatint version 3 Characterizing in Innovatint

CHARACTERIZING IN INNOVATINT LAB

7 | P a g e

Select the components you want to characterize and click “OK”. It will now appear in the big list:

But of course it has not been characterized yet. First set the specific gravity of the real components you

are going to characterize (so the S.G. as specified on the pot).

Page 9: characterizing in innovatint labmy.innovatint.com/data/download/public-files/... · 3/1/2017  · 201 characterizing in innovatint lab 7 Innovatint version 3 Characterizing in Innovatint

CHARACTERIZING IN INNOVATINT LAB

8 | P a g e

In the “Proposer” set which components you want to create mixtures for. In this case it would be only

the new base. When you would select a component that already has been characterized the program

will suggest new mixtures which will result in the loss of K/S data of that component!

Very important is that you select the correct template for the mixtures you are going to create as they

follow a set of mixtures tested by Chromaflo Technologies. When a template is missing or not suitable

for your needs you can also skip this part and add the mixtures manually in the “Bases” section by

selecting the component you are going to characterize.

Now you can start characterizing the new component(s).

Page 10: characterizing in innovatint labmy.innovatint.com/data/download/public-files/... · 3/1/2017  · 201 characterizing in innovatint lab 7 Innovatint version 3 Characterizing in Innovatint

CHARACTERIZING IN INNOVATINT LAB

9 | P a g e

Page 11: characterizing in innovatint labmy.innovatint.com/data/download/public-files/... · 3/1/2017  · 201 characterizing in innovatint lab 7 Innovatint version 3 Characterizing in Innovatint

CHARACTERIZING IN INNOVATINT LAB

10 | P a g e

2. Characterizing bases in existing database but other bootstrap

components

It could happen that for the characterization of new bases you would like to use a different black and

white colorant as bootstrap components which are not characterized yet. Also, as you don't have the

standard Chromaflo Technologies clear base, making a new bootstrap is not possible. To solve this, the

following steps should be followed.

NOTE: to get the best quality for the characterization it is preferred to use the bootstrap components

that were also used for the original characterization. Ask Chromaflo Technologies for the possibilities!

First add the colorants you need to add to your database. This can be done in the “Colorants” section.

You can of course also skip this and only add the new components in the characterization set without

actually using them in the database. See the previous chapter for this.

Also add the new products and bases to your system or just as components as explained in the previous

chapter.

Page 12: characterizing in innovatint labmy.innovatint.com/data/download/public-files/... · 3/1/2017  · 201 characterizing in innovatint lab 7 Innovatint version 3 Characterizing in Innovatint

CHARACTERIZING IN INNOVATINT LAB

11 | P a g e

After this go to the “Set components” section and add the colorants and bases to your characterization

set (only needed when not done directly yet). To be able to make a new bootstrap always a clear base

has to be used so make sure that at least that is added.

You can add the components by clicking on the “Add component(s)” button and selecting the new

components from here.

Page 13: characterizing in innovatint labmy.innovatint.com/data/download/public-files/... · 3/1/2017  · 201 characterizing in innovatint lab 7 Innovatint version 3 Characterizing in Innovatint

CHARACTERIZING IN INNOVATINT LAB

12 | P a g e

When you have configured your components you also have to change the bootstrap components.

Change them to follow your new base (or when you have the Chromaflo Technologies clear base you

don't change it) and set the new black and white colorant. It will give you a warning about removing

bootstrap components but in this case it can be ignored. Click “Yes” and continue the work. However,

when the original database still had the mixtures for the original components you will lose those as they

are based on the first bootstrap. Please keep this in mind. The K/S values will still be there and suitable

to be used for matching.

Set the densities for the new components.

Page 14: characterizing in innovatint labmy.innovatint.com/data/download/public-files/... · 3/1/2017  · 201 characterizing in innovatint lab 7 Innovatint version 3 Characterizing in Innovatint

CHARACTERIZING IN INNOVATINT LAB

13 | P a g e

Now go to the “Proposer”. In the “Proposer” set which components you want to create mixtures for. In

this case it would be only the new base. When you would select a component that already has been

characterized the program will suggest new mixtures which will result in the loss of K/S data of that

component!

In this case you need to make a new bootstrap so select this.

Propose the mixtures.

When you go to the “Colorants” section you will see that the bootstrap is showing mixtures based on

the black and white colorant + base. The warning light is green as it still has the K/S values from the old

bootstrap. When starting the measure the new mixtures and calculate the K/S values you will overwrite

the old bootstrap. The colorants that have been characterized with the old bootstrap will still be green

as the K/S values are still in the database. Same goes for the already characterized bases. Only the new

bases would show red and will ask you for mixtures. The others stay green.

Page 15: characterizing in innovatint labmy.innovatint.com/data/download/public-files/... · 3/1/2017  · 201 characterizing in innovatint lab 7 Innovatint version 3 Characterizing in Innovatint

CHARACTERIZING IN INNOVATINT LAB

14 | P a g e

Finish the characterization of the new bootstrap components and after this you are ready to also

characterize other bases as described in the previous chapter.

Page 16: characterizing in innovatint labmy.innovatint.com/data/download/public-files/... · 3/1/2017  · 201 characterizing in innovatint lab 7 Innovatint version 3 Characterizing in Innovatint

CHARACTERIZING IN INNOVATINT LAB

15 | P a g e

3. Characterizing colorants in existing database with or without

different bootstrap components

Characterizing colorants in an existing database can be done immediately when using the same

bootstrap components as the original database. When there is another black, white or product/ base

combination a new bootstrap has to be made first.

Going from scenario 1 where the components of the original bootstrap are used (so same white and

black base + Chromaflo Technologies standard clear base) the addition of a new colorant only means

adding the colorant in the “Configuration” section, add it in the “Set components” and make mixtures

with the “Proposer”.

When scenario 2 is in place where at least 1 of the bootstrap components is replaced you have two

options:

1. When the new bootstrap components that have to be replaced have already been characterized you can change it directly in the “Set components” section. As described in the previous chapters it will give you a warning about it and you will lose all mixtures from components made with the original bootstrap. The K/S values will be lost. When you have replaced the needed components you can move forward as described in scenario 1.

2. When the new bootstrap components have not been characterized you have to make the new bootstrap first. How to do this is explained in the previous section. After you have finished this you can add new colorants with the new bootstrap component(s).

Page 17: characterizing in innovatint labmy.innovatint.com/data/download/public-files/... · 3/1/2017  · 201 characterizing in innovatint lab 7 Innovatint version 3 Characterizing in Innovatint

CHARACTERIZING IN INNOVATINT LAB

16 | P a g e

4. Start from scratch

This is the easiest way to work but also it gives you the most work. To start from scratch the database

has to be build-up, the components have to be set, the bootstrap has to be made and all other

components have to be characterized.

To do this configure your database and make a complete new characterization set. This will make

everything new and gives you the opportunity to start with an empty characterization set.


Recommended