Check the sizes of all four supports..They keep varying in diameter as well as the height
Transcript
Page 1: Check the sizes of all four supports..They keep varying in diameter as well as the height.

Check the sizes of all four supports..They keep varying in diameter as well as the height

Page 2: Check the sizes of all four supports..They keep varying in diameter as well as the height.

Only one support. That too off-centered.

Page 3: Check the sizes of all four supports..They keep varying in diameter as well as the height.

The pillar in perspective. See the next column having two supports.

Page 4: Check the sizes of all four supports..They keep varying in diameter as well as the height.

If the previous support was for banking, then this pillar should not have two supports of different heights.

Page 5: Check the sizes of all four supports..They keep varying in diameter as well as the height.

The Concrete blocks are not of the same width through the stretch. The single support column under a thinner slab.

Page 6: Check the sizes of all four supports..They keep varying in diameter as well as the height.

The pillars differ in sizes from one to the next. This perspective is of the bridge running at the same level (supposed to be) but the pillar sizes differ.

Page 7: Check the sizes of all four supports..They keep varying in diameter as well as the height.

Again Single support.

Weight distribution is questionable.

Page 8: Check the sizes of all four supports..They keep varying in diameter as well as the height.

Banking is wrong! Exact opposite.

Yellow is just to indicate the correct tilt/banking.

This is the section that’s next to the one that collapsed. (this pic was taken before it was erected – see iron columns)

Page 9: Check the sizes of all four supports..They keep varying in diameter as well as the height.

Same section .. Just closer

Page 10: Check the sizes of all four supports..They keep varying in diameter as well as the height.
Page 11: Check the sizes of all four supports..They keep varying in diameter as well as the height.

Exactly how it was about two months back!

Page 12: Check the sizes of all four supports..They keep varying in diameter as well as the height.
Page 13: Check the sizes of all four supports..They keep varying in diameter as well as the height.
Page 14: Check the sizes of all four supports..They keep varying in diameter as well as the height.

• ITS NOT A DISASTER. -- IT’S A BLUNDER CAUSED BY SEVERAL CONTRACTERS, ENGINEERS, BUILDERS, LABOURERS AND NEVER THE LESS… A CONTRACT AGENCY. THE GOVERNMENT OFFICIAL WHO SANCTIONED THEM THE CONTRACT – THE GOVT OFFICIAL WHO EXAMINED THE PROGRESS OF THE FLYOVER REGULARLY.   IT MAY BE HUMANE TO ERR. BUT IT IS INHUMAN TO IGNORE THEM   REMEMBER FRIENDS – ILLEGAL EXCHANGE OF ONE RUPEE CAN COST TOO MANY LIVES – SAVE INDIA – ITS OURS.  