+ All Categories
Home > Documents > Chelsio Communications - Moderntech

Chelsio Communications - Moderntech

Date post: 08-Apr-2022
Category:
Upload: others
View: 5 times
Download: 0 times
Share this document with a friend
25
1 Chelsio Communications Chelsio for Cloud Computing Solutions May 2010
Transcript
Page 1: Chelsio Communications - Moderntech

1

ChelsioCommunications

Chelsio for Cloud Computing Solutions

May 2010

Page 2: Chelsio Communications - Moderntech

2

Cloud Computing

Networked Computing ResourcesComputing Nodes:

e.g. IBM BladeCenters, IBM e1350 racks, IBM iDataPlex

Storage Nodes: e.g. NetApp FAS 6080, NetApp v6000

Firewalls:

WAN Optimizations:

Virtualized and Accessible by Client via Internet

Fast networking is a key for Cloud Computing to be successful !

Page 3: Chelsio Communications - Moderntech

Data Center Demands

3

Reduce Costs

Support Global Operation

Always-on

Be more green

Improve agility and flexibility

Reduce risk

Page 4: Chelsio Communications - Moderntech

Data Center Solutions

Consolidation

Virtualization

Convergence

Page 5: Chelsio Communications - Moderntech

5

Fabric ConvergenceLAN

NAS

SAN HPC

Improves CPU efficiencyMinimizes software licensesSimplifies data center wiringLeverages staffing skills & tools

Lower Total Cost of Ownership

Improves cluster performanceLowers application latencyFaster backup and recoveryEnables storage applications

Higher Performance and New Apps

Convergence Benefits

Simplified network architecture – reduced operating costs

LAN

NAS

SANHPC

Edge Device

Low Cost non-DCE Switch Unified Wire AdapterNo GatewaySingle IT admin

Page 6: Chelsio Communications - Moderntech

Virtualization

To virtualize I/O intensive applications will require enhancements in the Hypervisor and hardwareNetQueue enabled ESX 4.0 was a start but more is needed

Chelsio’s adapters deliver high throughput to support I/O-intensive applicationsEight bi-directional data queues provide high throughput

Chelsio adapters are certified by:1. VMware ESX 4.02. VMware NetQueue enabled ESX 4.03. Citrix Xen Server 5.54. Microsoft Hyper-V5. Oracle VM

Page 7: Chelsio Communications - Moderntech

10GbE Medium of Choice

Source: Dell’Oro Group Feb. 2009

10 GbE Adapters Provide Compelling Cost SavingsOffer significant discount on a dollar-per-gigabit-of bandwidth over GbE adaptersBandwidth attractive to Cloud Computing and HPC Clustering applications and in Virtualized Data Centers

Page 8: Chelsio Communications - Moderntech

10GbE Medium of Choice

10GbE Shipment Growth will be DramaticLAN-on-Motherboard (LOM) adoption will be heavily driven by Blade Servers and by Server Virtualization

Source: Dell’Oro Group Feb. 2009

Page 9: Chelsio Communications - Moderntech

9

Chelsio Value Propositions in the Cloud

Networking, Storage, Clustering Protocols and Virtualization Unified Wire

NFSUnix/Linux File Server

CIFSMS Windows File Server

iSCSIBlocks over Ethernet

FCoE

HTTPWeb File Server

FTPFile Transfer

iWARPRDMA

NFS over RDMALustreRDMAVirtualization

Rack Servers

Computing Rack

Chelsio 10G

Blade Center

Storage

Page 10: Chelsio Communications - Moderntech

10

Large Application Footprint

Enterprise Data Centers

Web 2.0Customer Relationship Mgmt

Electronic Commerce

Database Clustering/Grid

Video editing/post production

IPTV, VOD

High-Performance Computing

Financial Services

Bio & Geo sciences, Oil & Gas

Aeronautical and Automotive

Digital Animation & Rendering

Electronic Design Automation

Government and Defense

Application Segments

10GigabitEthernet

SwitchesServers Storage

Chelsio Enables Fabric Convergence across all Data Center Infrastructure Segments

Page 11: Chelsio Communications - Moderntech

Ideal Cloud Computing Adapter

Provides Outstanding Throughput PerformanceProven performance in demanding HPC and storage applications

Provides Predictable Low LatencyOff-loads provide predictable latencies

Supports all Popular OSSupport for Linux “in the box”Certified for MS Windows Server

Supports a Broad Range of ApplicationsDemonstrated support for wide range of benchmarks and applications

Ability to Segregate the Various Traffic TypesAbility to do traffic management Ability to impose access controls

Provides Robust OperationField proven in enterprise environments

Page 12: Chelsio Communications - Moderntech

Chelsio Products for Clouds

Page 13: Chelsio Communications - Moderntech

13

Robust, Tested & Seasoned

Stateless NICSeveral Web 2.0 OEM wins Highest industry IOPs15M packets/secondHolder of all IPv4 & IPv6 land speed recordsMaximum virtualization featuresIntegrated Classification supportIntegrated Traffic Management support

TOEDeployed for four yearsOsaka University operating a 700 node cluster for 1+ yearIn the top 50 super computers in the worldWHQL-certified Chimney driver

iWARPSun Lustre team using T3 iWARPUCLA enables T3 iWARP across campus128-node Sandia cluster in use for over one yearSeveral Tier-1 server OEM winsWHQL-certified Network Direct driver

iSCSISeveral Tier-1 storage OEM winsIn-kernel support for Open-iSCSI OffloadiSCSI Boot support for Windows & Linux

The only Enterprise grade Unified Wire solution

Page 14: Chelsio Communications - Moderntech

Chelsio Traffic Management

Hardware based traffic management engine

Controls BW allocation for each application in a converged network

Controls BW allocation for each client in a virtualized cloud

Page 15: Chelsio Communications - Moderntech

B320E Bypass Server Adapter

HighlightsDual‐port 10GbE cardBased on the robust third generation T3 ASICChelsio T3 accelerator for fast, scalable, and reliable networkingLine‐rate full‐duplex 10Gbps performance for high‐I/O enterprise grade appliancesPCI Express x8 connectivity for extremely high bandwidthSupports extensive stateless offloadPowerful per‐connection, per‐server, and per‐interface configuration and controlIntegrated switch

ApplicationsWAN optimizationWeb accelerationLoad balancingInline intrusion preventionSecurityTraffic shaping

Ensure business continuity with Chelsio’s Bypass Adapter

Page 16: Chelsio Communications - Moderntech

Storage Products

16

Unified Storage ServerNFSCIFSiSCSINFSRDMALustreRDMAGUI or CLI MgmtSnapshotMirroringLogical Volume MgmtReplicationBackupsHigh AvailabilitySW or HW RAIDPerformance MonitoringLUN Masking

Convert any x86 or PPC platform into a storage target

Unified Manager NICTOEiSCSI InitiatoriSCSI BootSecurityGUI or CLI MgmtAuto DiscoveryNotification

Centrally manage the entire installation

iSCSIGUI or CLI Mgmt2x10Gb + 2x1GbCRC Digest OffloadLine rate with std frames2 x 8G FCHighly Available

Unified Storage Router

Converge with Ethernet, while preserving FC or IB investment

Competition USR-1100 QLGC iSR 6250

Target Redirection support X

Web based Mgmt X X

Half depth (IBM iDPx Fit) X

Active Failover Cluster X X

iSCSI Digest Offload X

Competition USS 1.1 FALC MSFT

Target Redirect support X

iSCSI Digest Offload X

NFSRDMA X

LustreRDMA X

HTTP X X

Persistent Reservation X X

Index Search X X

WAN Compression X X

Competition UM 1.0 ELX QLGC

Teaming support X

Boot configuration X X X

Hypervisor support X X

FW/Driver support X X X

System Network Mgmt X

Diagnostics support X X

Page 17: Chelsio Communications - Moderntech

Chelsio Product Support Multi OS Support

Deployment

Unified Manager: Complete Unified Wire Management

Monitor & Alert

Management

Statistics reportingSupport for event notificationOpen data format reportingMgmt stn GUI: Windows

Mobile, iPhoneInventory Management

OS firewallOS diskStorage initiatoriWARP (OFED/ND)System NetworkingNIC & TOE driverESX server, Hyper-V support &

Linux KVM support

Support for Boot-from-SANInstallation/Deployment of driversNetwork Teaming Auto-Discovery of HBA

Chelsio Traffic Manager Chelsio Hardware Filtering FCoE Initiator, Target supportSupport for Chelsio iSCSI TargetChelsio USS & USR Support

Windows 2003, 2008 RHEL 4, 5, SLES 10, 11Solaris 10 and Open Solaris FreeBSD, Mac OS

Page 18: Chelsio Communications - Moderntech

Computing Rack

Distributed/Central 10G Ethernet switches

Compute nodes with Chelsio 10GbE adapter for Ethernet

connectivity

Chelsio Unified Gateway box with 10GbE connectivity

FC Bridge connectivity

10GbE connectivity

Complete Solution overview Chelsio Products

18

Chelsio Unified Storage server for NAS/iSCSI Target with 10GbE connectivity

Page 19: Chelsio Communications - Moderntech

Benchmarks

Page 20: Chelsio Communications - Moderntech

20

Performance Benchmarks

Oracle RAC Performance MS Exchange Performance

North Carolina State University TOE test

Page 21: Chelsio Communications - Moderntech

21

STAC Financial Benchmarks

10GbE performance is comparable to or better than DDR IB

Page 22: Chelsio Communications - Moderntech

0

100

200

300

400

500

600

700

800

900

1GbE/TCP 10GbE/TCP 10GbE/RDMA 10GbE/TCP/TOE

MB

/s

Transport

NFS Xput

Write1

Write2

Read1

Read2

22

NFSoRDMA Benchmarks

linux-2.6.28-rc7cxgb3toe-1.1.022-2.6.284GB Ramfs for NFS share2GHZ quad-core AMD systems

NFSiWARP provides 30% more bandwidth than basic NFS

Page 23: Chelsio Communications - Moderntech

(Version 2008.0)

Elapsed Time (sec)

10GbE 32% faster than 1Gb, equal to DDR IB, for 32 cores23

Vienna Ab-initio SimulationPAM CRASH

Presenter
Presentation Notes
sdfdsf
Page 24: Chelsio Communications - Moderntech

RADIOSS 9.0: Speed up

(Version 9.0)Finite Element Solver

10GbE 30% faster than 1Gb, equal to DDR IB, for 64 cores24

Page 25: Chelsio Communications - Moderntech

25

Thank You!