Journal of Automatic Chemistry, Vol. 20, No. 4 (July-August 1998) pp. 99-108
Open focusedpreparation for rapidspecies determinationsolid samples
microwave-assisted sampletotal and mercuryin environmental
C. M. Tseng, H. Garraud, D. Amouroux, O. F. X.Donard*Laboratoire de Chimie Bio-Inorganique et Environnement, EP C2VRS 132,Universitd de Pau et des Pays de l’Adour, Hdlioparc, 64000 Pau, France
and A. de DiegoOn leave from the Department of Analytical Chemistry, University of the BasqueCountry, 644 P.K., 48080 Bilbao, Spain
This paper describes rapid, simple microwave-assisted leaching/digestion procedures for total and mercury species determination insediment samples and biomaterials. An open focused microwavesystem allowed the sample preparation time to be dramaticallyreduced to only 2-4 rain when a power of 40-80 W was applied.Quantitative leaching of methylmercuryfrom sediments by H2V03solution and complete dissolution of biomaterials by an alkalinesolution, such as 25% TMAH solution, were obtained. Methyl-mercury compounds were kept intact without decomposition orlosses by evaporation. Quantitative recoveries of total mercurywere achieved with a two-step microwave attack using a combina-tion ofHVO3 and H2 02 solutions as extractant. The whole pre-treatment procedure only takes 15rain, which can be furthershortened by an automated robust operation with an open focusedsystem. These analytical procedures were validated by the analysisof environmental certified reference materials. The results confirmthat the open focused microwave technique is a promising toolfor solid sample preparation in analytical and environmentalchemistry.
Introduction
Sample preparation is one of the most crucial steps intrace element analysis and frequently controls the qualityof the final results obtained [1, 2]. Environmental solidsamples are generally made into a solution with wetdigestion methods and analysed by compatible instru-mental techniques, e.g. atomic absorption spectrometry(AAS), inductively coupled plasma coupled to atomicemission spectrometry (ICP-AES) or ICP-mass spectro-metry (ICP-MS). Most of the conventional digestionprocedures are not only laborious and time-consuming,but also lack sufficient efficiency and reliability. As awell-known example, hot plate digestion techniques withconductive heating, now used widely, easily lead to non-
reproducible results. Other extraction methods, such assonication, distillation or soxhlet extraction, also have theabove drawbacks, even though reliable results are usuallyachieved. In the case of mercury speciation analysis, solid
Correspondence to Dr Donard.
sample preparation by acid or alkaline extraction withdifferent heating sources (sonication, stream distillation,etc.) requires from 2 to 24 h for complete recovery of thetarget analytes [3-10]. Innovative techniques such as
supercritical fluid extraction (SFE) [1 1-13] and micro-wave-assisted extraction (MAE) [14-16] have been re-
cently developed and are a substantial advance.However, SFE potentially has technological limitationsand shows insufficient extraction efficiency, usually de-pending on sample matrix and analyte polarity. More-over, the expensive equipment required increases the costof the analysis and the extraction step still takes 20-50 min.
The main advantages of the microwave-assisted extrac-tion technique are absence of inertia, rapidity of heating,reduction of extraction time, better reproducibilityand reliability, ease of automation, and good ability forselective leaching and total digestion in a wide array ofsample matrices [17]. Thus, the application of thistechnique to sample preparation has been widely inves-tigated in various fields of the environmental and analy-tical chemistry since it was first applied in 1975 [18]. Twodifferent approaches in microwave extraction proceduresare the use of a closed system (pressurized with a closedvessel) or an open system (non-pressurized with an openvessel). They have different characteristics and applica-tions, as shown in table [16]. Nevertheless, for organo-metallic speciation analysis, open microwave technologybased on focused microwaves is preferred to a closedmicrowave system, because better stability of the targetcompounds is achieved, due to the milder extractionconditions supplied (20-60W, compared to 1000Wtypically used in closed system); and better reproduci-bility is obtained, owing to a perfect control of the micro-wave energy, precisely focused on the sample. Essentialparameters such as extraction medium, applied power,exposure time and sample size must be, however, fullyoptimized in terms of stability and extraction efficiency ofthe target analytes to set the optimum extraction condi-tions for further routine analysis [14-16, 19, 20].
This paper presents microwave-assisted leaching/diges-tion protocols for total and mercury speciation analysis inenvironmental solid samples, such as sediments andbiological tissues, using an open and low-power focusedmicrowave system (301 PROLABO). Total mercury insediments was determined by flow injection sample in-troduction followed by ICP-MS detection, after two-stepmicrowave-assisted acid digestion with concentratedHNO3 and H202. Mercury species, such as methyl-and inorganic mercury, were analysed in both sedimentsand biological tissues by an automated on-line system
0142-0453/98 $12.00 @) 1998 Taylor & Francis Ltd99
C. M. Tseng et al. Open focused microwave-assisted sample preparation for rapid total and mercury species determination in environmental solid samples
Table 1. Comparison of the features between closed and open microwave systems for organometal speciation analysis.
Multimode microwave Focused microwaveItems closed system open system
Easy to handleOptimizationTemperature control
Microwave control
Automatic addition of reagent
Amount of sampleTotal digestionSpeciation analysisThroughput
Safety
Moderate ExcellentGood ExcellentGood Excellent
(only measured in one tube) (independent in each tube)Moderate Excellent
(multiple reflection in the cavity) (microwave focused on the sample)No Yes
(up to 4)<0.2g 0.1 to 5g
Excellent ExcellentGood Excellent
Excellent Good(up to 10 or 12 samples) (up to six samples)
Good Excellent
1. Take into account the operations needed to handle the microwave tubes and to recover the sample after thedigestion (cooling the tube and getting down the pressure inside).2. Microwave conditions (temperature, pressure, time) are dependent on the number of samples exposed at thesame time.
combining derivatization by ethylation or hydride gen-eration, cryogenic trapping, gas chromatography andquartz furnace atomic absorption spectrometric detection(D-CT-GC-QFAAS), after microwave-assisted acidleaching/alkaline digestion with nitric acid solution oralkaline solutions, such as TMAH (tetramethylammo-nium hydroxide) or KOH-methanolic solution, respec-tively. The proposed methods were validated by analysisof four certified reference sediments and three certifiedreference biological materials. The results obtained are ingood agreement with the certified values.
Materials and methods
Instrumentation
Microwave system" Sample extraction was carried out by a
single-mode open focused microwave digestor 301 (PRO-
LABO, France) with a frequency of 2450MHz and a
maximum power setting of 200W, equipped with a
TX 32 programmer. The power system provides a preciseand continuous microwave emission from 10 to 200 W, inincrements of 10 W, and allows a change of exposure timefrom to 99 min in steps of min. Both parameters areset by a TX 32 programmer. The microwave energy fromthe magnetron is delivered with high reproducibility andis focused on the sample. Thus higher heating efficiency isobtained. This single-mode microwave device was initi-allydesigned for sample extraction at atmospheric press-ure with an open vessel (figure 1). A reflux system and an
Aspivap fume treatment system (PROLABO, France)were used, to avoid possible losses of analytes and theescape of acid fumes generated during the extraction.
Flow injection-inductively coupled plasma-mass spectrometry:The FI-ICP-MS hyphenation includes a FIAS-200 FI
Obturator
Samplein solution
Focused microwaves
Figure 1. Open focused microwave system (PROLABO, model 301).
100
C. M. Tseng et al. Open focused microwave-assisted sample preparation for rapid total and mercury species determination in environmental solid samples
He 5.
Computer control lineTransfer lines
( Peristaltic pump
tN) Valves
] Voltmeter
[ Pneumatic pump
Figure 2. Schematic diagram of the hyphenated system combining derivatization by hydride generation or ethylation, cryogenic trapping, gaschromatography and quartz furnace atomic spectroscopy: 1, reagent vessel; 2, reaction vessel; 3, cryogenic trap and GC column; 4, quartzfurnace; 5, control panel; 6, flowmeters (adaptedfrom Journal of Atomic Analytical Spectrometry, 1997, 12, 629-635).
system (Perkin-Elmer, Germany) and an ELAN 5000ICP-MS instrument (Perkin-Elmer, Germany) and it hasbeen used for total mercury analysis. The FI systemincludes two peristaltic pumps and an injection valve,fully controlled by the ELAN software. The ELAN 5000ICP-MS instrument is equipped with a Scott-typedouble-pass spray chamber. Optimization was carriedout daily with a normal verification solution (10ng/g,Rh, Mg, Pb, Ce, Ba). Two isotopes of mercury (2Hg,2Hg) were measured in each determination to obtainreliable results, in order to avoid possible interference.Data acquisition was undertaken by the ELAN softwarethrough a personal computer (IBM PS/2 Model 70).Peak areas were used as the analytical response andmercury concentrations were calculated after normal-ization of the data to the internal standard signal(ST1) followed by appropriate blank subtraction.
Automated on-line hyphenated system: An automated on-linehypenated D-CT-GC-QFAAS system [14-16, 21, 22]was used for mercury species analysis. This systemcombines five basic analytical steps (see figure 2):derivatization of mercury species to volatile forms; pre-concentration by cryofocusing in liquid nitrogen; gaschromatographic separation during thermal desorption;detection by atomic absorption spectrometry; and dataacquisition by a computer. All the steps are controlledthrough an electronic panel, which is programmed by a
computer equipped with BORWIN software [23]. Theset-up includes a peristaltic pump, 250-ml reaction vessel,two electronic Teflon-valves, a U-shaped Pyrex column(45 cm length x 5 mm id), Dewar bath, pneumatic pump,adjustable d.c. power supply, flow meter, T-shapedquartz furnace (light path length 20 cm, cm id), atomic
absorption spectrometer (Model 5000, Perkin-Elmer)and PC. The operation procedure is automatically andsequentially performed according to a programme pre-viously defined in BORWIN software. First, NaBH4 or
NaBEt4 solution is quantitatively transferred from thereaction flask to the reaction vessel by a peristaltic pump.The derivatization and purging steps take place in a250-ml reaction vessel. The generated volatile Hg speciesare purged from the reaction vessel and trapped inthe column, packed with 2.5g of Chromosorb W HP(60-80mesh) coated with 10% SP2100 (Supelco) andpreviously silanized with hexamethyldisilazane (Fluka).During cryofocusing, the column is immersed in a Dewarbath with liquid N (-196C) lifted by a pneumaticpump. In the desorption step, the column, wrapped with0.5-mm-diameter Nichrome wire, is gradually heated byan adjustable power supply and the volatile mercuryspecies successively elute in order of increasing molecularweight. The flow of the purging/stripping He gas iscontrolled by a flow meter. Atomization of mercuryspecies occurs in a quartz furnace held at 800C bymeans of an MHS-20 unit and detected by an atomicabsorption spectrometer operated at 253.7 nm with a0.7 nm slit-width. Data acquisition is finally undertakenby a chromatographic software run on a PC.
Reagents
Analytical grade chemicals and Milli-Qwater were usedthroughout (unless otherwise stated). A 0.1% mixedsolution containing ml of Triton X-100, g of EDTAand ml of NH4OH (25%), diluted to a final volume of
with Milli-Q water, was prepared. An approximately0.01% (m/v) solution of sodium tetraethylborate
101
C. M. Tseng et al. Open focused microwave-assisted sample preparation for rapid total and mercury species determination in environmental solid samples
(NaBEt4) was prepared in a glove-bag, filled with N2, bydissolving the reagent in water. An approximately 4%(m/v) solution of NaBH4 was prepared by dissolving thereagent in water. All vessels were first cleaned with RBS50 detergent, thoroughly rinsed with tap water, soaked ina 10% HNO3 solution for 24h and finally rinsed withMilli-Q water before use.
Standard solutions and certified reference materials
A standard stock solution of 1000 lag m1-1 of Hg(II) was
prepared by dissolving mercury(II) chloride in 1%HNO3, and that of 1000 lag m1-1 of methylmercury bydissolving methylmercury chloride in methanol. All stocksolutions were stored in a refrigerator and protectedagainst light. Working standard solutions were preparedby appropriate dilution in water of the stock solutionsand they were stored one week at maximum.
Four certified reference sediments, IAEA-356 (Interna-tional Atomic Energy Agency of Monaco), PASC-1(National Research Council of Canada), BCR S19 andCRM 580 (Community Bureau of Reference) and threebiological reference materials, DORM-1 (Dogfishmuscle) and TORT-1 (Lobster hepatopancreas) (Na-tional Research Council of Canada) and CRM 463(Tuna fish muscle) (Community Bureau of Reference),were used to validate the proposed methods.
Analytical procedures
Analysis of sediments
Mercury species analysis: A sample of approximately g ofhomogenized dry sediment and 10ml of acid solutionwere placed in an extraction tube and exposed tomicrowave irradiation at 60 W for 3 min. After irradia-tion, the sample solution was cooled to room tempera-ture, transferred to a 15ml tube and centrifuged at5000 rpm for 5 min. The supernatant was poured into a
22-ml Pyrex vial with Teflon cap (Supelco) and finallystored in a refrigerator until analysis. A clean-up proce-dure was not necessary prior to the analysis after theaqueous phase ethylation method. An aliquot of ml ofthe extract was analysed by means of the hyphenatedEt-CT-GC-QFAAS system. Calibration was performedby the three-point standard-addition method to over-come possible matrix interferences and the sub-samplewas subjected to triplicate analysis. Blanks were run aftereach triplicate analysis to check for the possible memoryeffects.
Total mercury analysis: A sample of approximately 0.25 g ofhomogenized dry sediment and 8ml of concentratednitric acid were placed in an extraction tube and exposedto microwave irradiation at 20 W for 5 min. After extrac-tion, the sample was allowed to cool for about 5 min,followed by the addition of 2ml of H20 and againdigested at 20W for further 5 min. After cooling, theextracts were diluted with Milli-Q water and finallystored in a refrigerator until analysis. An aliquot of0.1 ml of the extract was added to a final solution(5 ml) containing 4 ml of a mixed Triton X-100 solution,which included 0.1% Triton X-100, 0.1% EDTA and
0.1% (v/v) ammonia solution, and an internal standardof thallium (100 ng). The resulting solution was analysedby FI-ICP-MS. The three-point standard-additionmethod in the same extract, and the addition of aninternal standard were used to overcome matrix effectsand instabilities of the instrument. Analyses were carriedout in duplicate and measured using two isotopes ofmercury (Hg, Hg). A blank test was prepared ineach set of experiments to check for possible contamina-tion during sample preparation and it was used tocalculate the concentration of mercury after appropriateblank subtraction.
Analysis of biotissues
Mercury species analysis: A sample of 0.1-0.5g of pulver-ized freeze-dried tissue and 5 ml of 25% TMAH alkalinesolution were placed in an extraction tube and exposed tomicrowave irradiation at 60W for 2 min. After irradia-tion, the sample solution was cooled to room temperatureand then diluted with 5ml of methanol. It was thentransferred into a 22-ml Pyrex vial with a Teflon cap andstored in a refrigerator until analysis. It is not necessaryto have a clean-up stage before analysis by hydridegeneration. Aliquots of 50-300lal of the extract weredirectly analysed by the HG-CT-GC-QFAAS hyphen-ated system. The calibration, reproducibility analysis andblank test carried out in this case are similar to thosealready described for the analysis of sediments.
FI-ICP-MS and automated on-Line D-CT-GC-O..FAAS condi-tions: The optimum parameters for FI-ICP-MS andautomated on-line D-CT-GC-QFAAS operation aresummarized in table 2.
Results and discussion
Optimum strategy for microwave-assisted extraction
Extraction efficiency is the key to a successful microwave-assisted sample preparation for total and mercury speciesdetermination in environmental solution samples. Inmercury speciation analysis, the extraction step must
provide quantitative speciation of mercury species fromthe matrix without losses or contamination, and withoutchanges in chemical forms; in total mercury analysis,mercury species must be not only completely liberatedfrom the matrix, but also decomposed to Hg(II) withoutany loss and contamination. As a result, several variables,such as power applied, exposure time, and concentrationand amount of extractant, must be carefully optimizedwhen using an open focused microwave system. Once theoptimum extraction agents have been chosen, the twomost important variables influencing the extractionefficiency are power applied and exposure time. Figure3 shows a generic view of extraction efficiency in thepower setting versus irradiation time region. The domainof optimum efficiency is located in region B; in region C,above the boundary line of the upper limit, insufficientefficiency is achieved due to degradation or evaporationlosses, because of a long time heating or intensive powersetting. In region A, below the boundary line of the lowerlimit, incomplete dissolution or leaching also leads to
102
C. M. Tseng et al. Open focused microwave-assisted sample preparation for rapid total and mercury species determination in environmental solid samples
Table 2. Optimum conditions for the automated on-line D-CT-GC-O_.,FAAS system and FI-ICP-MS system for mercury speciation andtotal mercury analysis.
D-CT-GC-QFAAS FI-ICP-MS
Hydride Ethylation
Derivatization ICP-MS conditionsDerivatization solution 5 ml of 4% m/v of NaBH4 10ml of 0.01% m/v of NaBEt4 Forward rf power 1100 WSolution pH 0.2 ml of 12 mol 1-1 HC1 4, 0.5 ml of 2 mol dm-3 Plasma gas flow rate 151 min-1
acetic/acetate bufferReaction time 0.5 min 3 min Auxiliary gas flow rate 0.81 min-1
Nebulizer gas flow rate 0.981 min-1
Cryogenic trappingGC column U-shape glass tube, 45 cm U-shaped glass tube, 45 cm Sampler and skimmer cones Nickel
length, 5 mm id length, 5 mm idGC phase 10% SP-2100 on Chromosorb 10% SP-2100 on Chromosorb
W-HP 60/80 mesh size W-ItP 60/80 mesh size Data acquisitionCarrier gas Helium (99.995%) Helium (99.995%) Scan mode Peak hop transientPre-cooling duration min min Dwell time 100 msPurging duration 4.5 min 10 min Sweeps per reading 5Purging flow rate 150 ml min- 150 ml min- Readings per replicate 60
No. of replicatesDesorptionStripping gas Helium (99.995%) Helium (99.995%) Signal processing IntegratedStripping flow rate 150 ml min-1 150 ml min-1 Isotope measured 22Hg, 2HgDesorption voltage 30 V 30 V Internal standard 5T1
Data acquisitionInstrument Perkin Elmer AAS 5000 Perkin Elmer AAS 5100Wavelength 253.7 nm 253.7 nmQuartz furnace temperature 800C 800CAcquisition duration 4 min 5 min
90%
Extraction time
}0%
Figure 3. Generic response surface of methylmercury recoveries ina microwave power versus extraction time.
poor recoveries. The positions of both boundary linesmay shift up and down depending on the strength of theextraction agent used and of the metal-matrix bonds.The energy focused on the sample can be calculated ateach point in the matrix map of the power setting versusirradiation time according to: Q, W x T (where Q, isthe energy output in cal, W is power setting in cal/minand T is the exposure time in min). Diagrams like that infigure 3 provide information about the optimum condi-tions required in each case to get quantitative recoveriesduring routine work, even though the energy needed tobreak the carbon-metal bonds remains unknown.
Microwave-assisted extraction of sediments
Mercury speciation analysis: The choice of extractionmedium is the first step towards understanding thebehaviour and extraction efficiency of methylmercuryfrom sediments under mild microwave irradiation [14-16, 19, 20]. Acid solutions have commonly been used inthe extraction of organomercury compounds from sedi-ments [9, 24-28]. Thus, four different acid solutions,nitric (2 mol dm-3), hydrochloric (2 mol dm-3), sulphu-ric (1 mol dm-) and acetic acids (100%), were selectedto check the stability of MeHg+ and to investigate theMeHg+ extraction efficiency from reference sediments ina microwave field. Each of the extractants was spikedwith an amount of MeHg+ and exposed to a microwavefield during varying heating time at 60W. The resultsobtained after up to 8 min heating show good stability ofMeHg+ in HNO3 and HC1 solutions, but only 80-90% ofaveraged MeHg+ recoveries in H2SO4 and CHCOOHsolvents. MeHg+ losses are probably due to evaporationof extractant during vigorous heating. In another set ofexperiments, reference sediments suspended in the acidsolutions mentioned above were exposed to microwaves at60 W for 3 min. Quantitative recoveries were obtained by2 M nitric and hydrochloric acids. Overall recoveries ofabout 85% and 55% for pure acetic acid and mol dm-3
sulphuric acid were observed, respectively. These lowrecoveries are mainly due to incomplete recovery fromsediments by CH3COOH and partial adsorption on fineorganic particles in the case of H2SO4. Additionally,interference problems were achieved in the determinationstep when analysing HC1, HSO4 and CHCOOH
103
C. M. Tseng et al. Open focused microwave-assisted sample preparation for rapid total and mercury species determination in environmental solid samples
100
80
40-
:20-
(a)100%
9?%
100%.... -.. 962o’o-., 100
] 80%.
00 2 4 6 8 2 4 6 8
Extraction time (min) Extraction time (min)
Figure 4. Methylmercury recoveriesfrom (a) BCR $19 and CRM N580 certified materials (extractant, 1Oral of 2M HN03; sediment,l g) and (b) CRM 463 certified material (extractant, 5ml of 25% TMAH; tissue, 0.2g) as function of power applied versus timeirradiation.
leachates. This was not the case, however, for HNO3leachates. Taking into account all the facts mentionedabove, nitric acid solution is an excellent extractant formethylmercury leaching from sediments, in terms ofextraction efficiency and matrix interference. MeHg+microwave-assisted leaching from sediments with2moldm- HNO was, therefore, optimized by con-
structing the corresponding response surface of powerapplied versus time irradiation using BCR S19 and CRMN580 reference materials [Figure 4(a)]. The optimumyields (100%) were obtained in 1-7 min in the 100-20 Wrange. Extreme conditions (longer time heating and/orhigher power setting) result in evaporation losses or inrapid boiling out of the extractant, even though quanti-tative recovery may be achieved. Summarizing, 2-4 minheating versus 60-40W power conditions are recom-mended as the optimum condition for microwave-assistedleaching of methylmercury from sediments using2 moldm- HNO3 as extractant. In a further recoverystudy, the effect of changing HNO3 concentration was
investigated. Quantitative and non-destructive MeHg+recovery was obtained by extraction with 2 mol dm-3 upto 10moldm- HNO, at 60W for 3 min irradiation;moldm- HNO3 led to insufficient recovery and de-
gradation of MeHg+ for concentrated HNO.
Analytical figures of merit: A flow chart of the analyticalprocedure developed for methylmercury determinationin sediments is shown in figure 5. It was validated bythe analysis of three different certified referencesediments, BCR 19, CRM N580 and IAEA-356, using2 and 6moldm-3 HNO3 solution as extractant. Theresults are in good agreement with the certified values,and reproducibility is similar to those obtained byconventional methods (table 3). The detection limitwas calculated as 0.5ng of MeHg+ as Hg per g ofdry sediment, with a linearity range from 0.5 to 100ngof MeHg+ as Hg. The comparison of the slope ofthe calibration curve with that obtained using aqueousHNO spiked with MeHg+ confirms that the analysisis not affected by matrix effects. No clean-up procedureis necessary, but the extract must be centrifuged aftermicrowave irradiation prior to the analysis, in order to
prevent readsorption on suspended matter. Thechromatogram in figure 6(a) was obtained for theanalysis of the reference CRM N580 sediment using6moldm-3 HNO3 solution as extractant. The peak at1.3 min corresponds to Hg and is due to reduction ofHg2+ during the determination step. High contentof Hg2+ in sediments is responsible for the appearanceof such a peak for Hg.
Tot ’ion
1"--- 8 ml Conc. HNO .MWDigestion
20 W
Cooling .2 m130% H202
MWDigestion20 W
FIA-ICP/MS
10 mlHNO3(2M or 6M)
MWLeaching60 W
Centrifugation
adjustpH
On-line
NaBEt4 ethylation
CT/GC/QFAAS
Speciation
5 ml TMAH(25%)
MWDissolution
60 W
adjustpH
On-line
NaBH hydride generation
CT/GC/QFAAS
Figure 5. Schematic analytical protocols for total and mercury speciation analysis in environmental samples.
104
C. M. Tseng et al. Open focused microwave-assisted sample preparation for rapid total and mercury species determination in environmental solid samples
50000
40000
30000
20000
10000
(a)
MeHg/
Hg
1.0 2.0 3.0 4.0 5.0
Retention time (min)
35000
30000
25000
20000
15000
10000
(b) MeHg/
0.5 1.0 1.5 2.0 2.5 3.0
Retention time (min)
Figure 6. Typical chromatograms of mercury species obtained by following the proposed procedures for (a) CRM W580 (0.5ml of 6MHW03 extract) and (b) Dorm-1 (200#1 of 25% TMAH extract) certified materials
Table 3. Results for the determination of methylmercury in certified reference sediments using HgVO
2 moldm-3 or 6tool dm-3 as extractant in the microwave assisted extraction step.
Concentration of MeHg+ (ngg-Sediment Determined Certified
HNO3 2 mol dm-3 HNO 6 mol dm-BCR S19 51.9 +/- 5.1 50.6 +/- 4.5 53.1 +/- 8.6CRM 580 79.6 +/- 3.0 73.3 + 5.7 75.4 +/- 5.0IAEA-356 5.49 +/- 0.72 Not analysed 5.87 + 0.41
1. Calculated for dry mass.2. Six independent experiments.
Total mercury analysis: The choice of the best extractionagent for microwave-assisted digestion and of the mostappropriate analytical technique for the final determina-tion are of crucial importance in total mercury analysis[29]. Mercury species are easily and strongly bound toorganic matter, e.g. thiol groups, humic substances andamino acids. Thus, oxidizing agents such as concentratedHNO3 and H202 solution were chosen to liberate the
mercury species from the organic matrix and to fullyoxidize them to Hg(II). The use of sulphuric acid asextractant is not recommended. The simple digestionprocedure proposed here is as follows: the sediment(about 0.25 g) is decomposed by a two-step attack with(1) concentrated HNO at 20W power for 5min,followed by cooling the mixture about 5 min; and (2) a
subsequent extraction with 30% H202 at 20 W power for
105
C. M. Tseng et al. Open focused microwave-assisted sample preparation for rapid total and mercury species determination in environmental solid samples
Table 4. Resultsfor the determination of total mercury in certifiedreference sediments.
Total mercury concentration (#gg-1)
Sediment Determined2 Certified
BCR S 19 95 4- 3 91.07IAEA-356 7.3 4- 0.1 7.62PACS-1 4.7 4- 0.3 4.57 4- 0.16
1. Calculated for dry mass.
2. Results given with 95% confidence interval.
5 min. Mild conditions prevent losses of mercury as Hgduring intensive microwave digestion in an open system.The results obtained after the analysis of the extractsby FI-ICP-MS showed the quantitatively and reprodu-cibility of the digestion procedure described above. Theuse of an open-vessel microwave system facilitates theaddition of the second reagent. No contamination wasobserved throughout all the experiments.
Analyticalfigures of merit: The simple analytical procedureillustrated in figure 5 takes only 15 min per sample. It canbe shortened by automatic robust operation with an openfocused microwave system when analysing samples inseries. The method was validated by the analysis of threecertified reference sediments, PASC-1, IAEA-356 andBCR S19, by FI-ICP-MS detection. The results obtainedin the determination of total mercury are in goodagreement with the certified values (table 4). Obtainedrecoveries ranged from 95 to 105% and the reproduci-bility was better than 10% in a mercury concentrationrange between 4 and 100 lag g-. The addition of TritonX-100 as surfactant and ETDA as complexing agent isnecessary to obtain linear calibration curves in order toeliminate memory effects and improve efficiency duringsample transport [29]. The use of an FI system prior toICP-MS detection, standard addition method and com-plexation of mercury by EDTA improves reliability of theresults, compared to conventional ICP-MS methodsusing direct calibration. Detection limits, calculated as
three times the standard deviation of the blank dividedby the slope of the calibration curve, are 10 pg g-1 and1.0 ng g-1 for solutions and dry sediment samples, respec-tively.
Microwave-assisted extraction of biomaterials
Mercury speciation analysis: To obtain quantitative recov-eries of mercury species incorporated in the biologicalmatrix, complete dissolution of the biological tissue isnecessary [15, 16, 30]. Two candidate approaches toobtain good solubilization of biotissues are acid andalkaline hydrolysis procedures. In this study, five extrac-tion agents, HNO3, HC1, CH,3COOH, TMAH andmethanolic-KOH solutions, were investigated to under-stand the stability and extraction efficiency of methyl-mercury in simple solutions and reference biomaterials.MeHg+ stability in simple solutions was tested in thesame way as for the sediments (see earlier). MeHg+ was
spiked in each extraction medium, followed by irradia-tion at a preset power for varying heating times. Quanti-tative recoveries were obtained for TMAH after 6 min of
heating at 40 W power, whereas only 85-90% yields wereobserved for CHCOOH and methanolic-KOH, owingto volatile losses during long heating time. For concen-trated HNO and HC1 MeHg+, recoveries quicklydecreased with heating time due to rapid breakdownand partial evaporation losses of MeHg+ after 6 min ofheating. Recoveries of MeHg+ from reference biotissuesat 40W power for 4min of irradiation significantlydiffer between solutions. Quantitative recoveries were
systematically obtained with alkaline solutions such as
25% TMAH and methanolic KOH solutions. Poorrecoveries were found, however, when using concentratedHNO and HC1, owing to degradation and evaporationlosses of MeHg+ during microwave irradiation. As to
pure acetic acid, lower yields of both methyl- andinorganic mercury were obtained using pure acetic acidas extractant due to incomplete dissolution of the tissue.Alkaline digestion was selected for MeHg+ determinationin biotissues. The potential chemical mechanisms ofMeHg+ extraction from organic matrix with acid oralkaline digestion have been previously discussed [15].Owing to its higher extraction efficiency and lowersolution volatility, compared with methanolic-KOHsolution, 25% TMAH solution was chosen as extractantto investigate the optimum conditions for microwave-assisted digestion of biotissues. The power applied versustime irradiation response surface for MeHg+ recoveriesfrom CRM 463 biomaterial is shown in figure 4(b).Similar to the study of MeHg+ optimization in sedi-ments, the zone of quantitative yields (100%) is locatedat 1-6min and 100-20W. Special care must be taken,however, to avoid evaporation losses or rapid boiling outof the extractant in the case of long time heating and highpower setting. As a result, irradiation for 2-4 min at 60-40 W using 25% TMAH solution as extractant is recom-mended as the optimum condition for microwave-assistedalkaline digestion of tissues in an open focused microwavesystem. In a further recovery study, the effect of variousTMAH concentrations was investigated. QuantitativeMeHg+ recovery was obtained by extraction with 10-25% TMAH solution for 0.2-0.5 g of dry biotissue at60W for 2min irradiation. These conditions allowedsimultaneous quantitative extraction of methyl- andinorganic mercury from biomaterials.
Analytical figures of merit." The biotissue extract aftermicrowave digestion can be analysed without anyclean-up step [see figure 5]. The proposed analyticalprocedure was validated by analysing (HG-CT-QFAAS)three different reference biomaterials, CRM 463,DORM-1 and DORT-1, after 2min/60W microwave-assisted digestion of 0.1-0.5g of tissue with 5ml of25% TMAH solution. The results obtained for methyl-mercury are in good agreement with the certified values,as shown in table 5. Inorganic mercury can also besimultaneously extracted and determined by thismethod. The sums of the concentrations of both mercuryspecies present in the tissues also match certified totallnercury content in the biotissues (table 5). A reproduci-bility of 4-10% was obtained in the determination ofboth mercury species. The detection limits for bothHg+2 and MeHg+ were calculated as 50ngg-I for0.2 g of pulverized dry sample and 0.05 ml of extract.Additionally, quantitative MeHg+ recoveries were also
106
121. M. Tseng et al. Open focused microwave-assisted sample preparation for rapid total and mercury species determination in environmental solid samples
Table 5. Results for the determination of methylmercury and inorganic mercury in certified reference biological tissues.
Concentration (#gg-1) as Hg
Determined2 CertifiedSediment Hg+ MeHg+ Total Hg Hg+ MeHg+ Total Hg
CRM 463 0.235 -t- 0.030 2.735 -t- 0.106 2.970 -t- 0.110 0.02 -t- 0.22 2.83 -t- 0.15 2.85 + 0.16DORM-1 0.120 -t- 0.035 0.728 -t- 0.028 0.848 + 0.045 0.067 + 0.095 0.731 + 0.060 0.798 + 0.074TORT-1 0.184+0.024 0.142-+-0.017 0.326-t-0.029 0.202+0.062 0.128-t-0.014 0.33-t-0.06
1. Calculated for dry mass.2. Three independent experiments.3. Calculated as Hg+ + MeHg+.4. Calculated as total Hg- MeHg+.
observed for up to g of dry biotissue using 5ml of25% TMAH solution as extractant. A typical chromato-gram obtained for DORM-1 reference biotissue is shownin figure 6 (b).
Conclusions
Simple, rapid, efficient and quantitative sample leaching/digestion protocols based on a microwave-assisted tech-nique have been developed for the determination of totaland mercury species in environmental solid samples suchas sediments and biomaterials. The use of an openfocused microwave system offers reproducible and quan-titative recovery of the analytes and keeps the organo-mercury species intact. The appropriate extractants, acombination of HNO3/H202, HNO3 and 25% TMAHsolutions, were chosen for total and mercury speciesdetermination in sediments and biotissues after carefulevaluation of the stability and extraction efficiency ofmethylmercury in a microwave field. Optimum extrac-tion conditions of 2-4min irradiation and 40-60Wpower were selected for mercury speciation analysisfollowing a matrix approach. Sample throughput canbe controlled by instrumental analysis time, rather thanby sample preparation step. A drastic reduction of time isachieved in sample preparation when microwave tech-nology is used, compared to other currently availablemethods [15, 16, 31]. Microwave-assisted techniques fortotal and mercury speciation analysis offer advantages interms of simplicity, reliability and analysis time and cost.This technique might be extended to provide similarsample preparation protocols for other metal and metal-loids in environmental metrices [31-33].
Acknowledgements
The authors wish to thank D. Mathd (Prolabo) for use ofa commercial A301 microwave digestor; and MessrsLobinski, Szpunar and Schmitt for their contribution tothe microwave-assisted speciation-related research. C. M.Tseng acknowledges the Taiwan Government for hisPhD grant. A. de Diego is grateful to the SpanishGovernment for his post-doctoral fellowship.
References
1. Q,UEVAUVILLER, PI-I., MAIER, tB. A. and GRIEPINK, B., 1995, InQuality Assurance for Environmental Analysis, Eds Quevauviller, Ph.,Maier, E. A., and Griepink, B. (Amsterdam: Elsevier).
2. DRABAEK, I. and IVERfELDT, A., 1995, In Quality Assurance forEnvzronmental Analyszs, Eds, Quevauviller, Ph., Maier, E. A., andGriepink, B. (Amsterdam: Elsevier).
3. BLOOM, N. S.J., 1989, Canadian Journal of Fishery and Aquatic Science,46, 1131.
4. FISCHER, e., RAPSOMANIKIS, S. and ANDREAE, M. O., 1993,Analytical Chemistry, 65, 763.
5. PuK, R. and WE]FR, J. H., 1994, Analytica Chimica Acta, 292, 175.6. HORVAT, M., MAY, K., STOEPPLER, M. and BYRNE, A. R., 1988,
Applied Organometallic Chemistry, 2, 515.7. HORVAT, M., BLOOM, N. S. and LIANG, L., 1993, Analytica Chimica
Acta, 135.8. LEE, Y. H., MUNTI-IE, J. and IVERFELDT, ., 1994, Applied
Organometallic Chemistry, 8, 659.9. MAY, K., STOEPPLER, M. and REISINGER, K., 1987, Toxicological
and Environmental Chemistry, 13, 153.10. LIANG, L., HORVAT, M., CERNICHIARI, g., GELEIN, B. and BALOGH,
S., 1996, Talanta, 43, 183.11. HOLAK, W. J., 1995, AOAC International, 78, 1124.12. EMTEBORO, H., BJORKLUND, E., ODMAN, E, KARLSSON, L.,
MATHIASSON, L., FRECH, W. and BAXTER, D., 1996, Analyst, 121, 19.13. CLELAND, S. L., OLSON, L. K., CARUSO, J. A. and CAREY, J. M.,
1994, Journal of Analytical and Atomic Spectrometry, 9, 975.14. TSENO, C. M., DE DIEGO, A., MARTIN, E M. and DONARD, O. E X.,
1997, Journal of Analytical and Atomic Spectrometry, 12, 629.15. TSENO, C. M., DE DIEGO, A., MARTIN, E M., AMOUROUX, D. and
DONARD, O. F. X., 1997, Journal of Analytical and Atomic Spectrometry,12, 743.
16. TSENG, C. M., ScnITT, V. O., DE DIEGO, A. and DONARD, O. E X.,1998, submitted to American Environmental Laboratory.
17 KINOSTON, H. M. and JASSlE, L. B., 1988, Introduction to MicrowaveSample Preparation (Washington, D.C.: ASC).
18 ABU-SAMRA, A., MORRXS, J. S. and KOIRTYOHANN, S. R., 1975,Analytical Chemistry, 47, 1475.
19 DONARD, O. E X., LALERE, B., MARTIN, E and LOBINSKI, R., 1995,Analytical Chemistry, 67, 4250.
20 LALERE, B., SZPUNAR, J., BUDZlNSKI, H., GARRIOUES, R andDONARD, O. E X., 1995, Analyst, 120, 2665.
21 DE DIEGO, A., PECHEYRAN, C.,TSENG, C. M. and DONARD, O. E X.,1998, submitted.
22 TSEN, C. M., DE DEGO, A., AMOUROUX, D. and DONARD, O. F. X.,1998, submitted.
23 Logiciel Intuitif pour la Chromatograph#, version 1.2 (JMBSDeveloppements).
24. HEMPEL, M., HINTELMANN, H. and WILKEN, R.-D., 1992, Analyst,117, 669.
25. HINTELMANN, H. and WILKEN, R.-D., 1993, Applied OrganometallicChemistry, 7, 173.
26. QUEVAUVILLER, P., DONARD, O. E X., WASSERMAN, J. C., MARTIN,E M. and SCHNEIDER, J., 1992, Applied Organometalhc Chemistry, 6,221.
27. LO>OBOTrOM, J. E., DESSMAN, R. C. and LICHTEN]ERO, J. C. J.,1973, Journal of AOAC International, 56, 1297.
107
121. M. Tseng et al. Open focused microwave-assisted sample preparation for rapid total and mercury species determination in environmental solid samples
28. HORVAT, M., BYRNE, A. R. and MAY, K. 1990, Talanta, 37,207.
29. WOLLER, A., GARRAUD, H., MARTIN, F., DONARD, O. F. X. andFODOR, P., 1997, Journal of Analytical and Atomic Spectrometry, 12, 53.
30. SZPUNAR, J., SCHMITT, V. O., LOBINSKI, R. and MONOD, J.-L., 1996,Journal of Analytical and Atomic Spectrometry, 11, 193.
31. SCHMITT, V. O., DE DIEOO, A., COSNIER, A., TSENG, C. M., MOREAU,J. and DONARD, O. F. X., 1996, Spectroscopy, 13, 99.
32. SCHMITT, V. O., SZPUNAR, J., DONARD, O. F. X. and LOBINSKI, R.,1997, Canadian Journal of Scientific Spectroscopy, 42, 419.
33. SZPUNAR, J., SCHMITT, V. O., DONARD, O. F. X. and LOBINSKI, R.,1996, Trends in Analytical Chemistry, 15, 181.
108
Submit your manuscripts athttp://www.hindawi.com
Hindawi Publishing Corporationhttp://www.hindawi.com Volume 2014
Inorganic ChemistryInternational Journal of
Hindawi Publishing Corporation http://www.hindawi.com Volume 2014
International Journal ofPhotoenergy
Hindawi Publishing Corporationhttp://www.hindawi.com Volume 2014
Carbohydrate Chemistry
International Journal of
Hindawi Publishing Corporationhttp://www.hindawi.com Volume 2014
Journal of
Chemistry
Hindawi Publishing Corporationhttp://www.hindawi.com Volume 2014
Advances in
Physical Chemistry
Hindawi Publishing Corporationhttp://www.hindawi.com
Analytical Methods in Chemistry
Journal of
Volume 2014
Bioinorganic Chemistry and ApplicationsHindawi Publishing Corporationhttp://www.hindawi.com Volume 2014
SpectroscopyInternational Journal of
Hindawi Publishing Corporationhttp://www.hindawi.com Volume 2014
The Scientific World JournalHindawi Publishing Corporation http://www.hindawi.com Volume 2014
Medicinal ChemistryInternational Journal of
Hindawi Publishing Corporationhttp://www.hindawi.com Volume 2014
Chromatography Research International
Hindawi Publishing Corporationhttp://www.hindawi.com Volume 2014
Applied ChemistryJournal of
Hindawi Publishing Corporationhttp://www.hindawi.com Volume 2014
Hindawi Publishing Corporationhttp://www.hindawi.com Volume 2014
Theoretical ChemistryJournal of
Hindawi Publishing Corporationhttp://www.hindawi.com Volume 2014
Journal of
Spectroscopy
Analytical ChemistryInternational Journal of
Hindawi Publishing Corporationhttp://www.hindawi.com Volume 2014
Journal of
Hindawi Publishing Corporationhttp://www.hindawi.com Volume 2014
Quantum Chemistry
Hindawi Publishing Corporationhttp://www.hindawi.com Volume 2014
Organic Chemistry International
ElectrochemistryInternational Journal of
Hindawi Publishing Corporation http://www.hindawi.com Volume 2014
Hindawi Publishing Corporationhttp://www.hindawi.com Volume 2014
CatalystsJournal of