Chlorometer Duo Palintest Ltd Palintest House, Kingsway, Team Valley, Gateshead, Tyne & Wear, NE11 0NS, England Tel: +44 (0) 191 491 0808 Fax: +44 (0) 191 482 5372 Email: [email protected] Website: www.palintest.com Palintest USA 21 Kenton Lands Road, Erlanger, Kentucky 41018, USA Tel: (859) 341 7423 Toll Free: 800 835 9629 Fax: (859) 341 2106 Email: [email protected] Website: www.palintestusa.com Palintest Australia/Asia Pacific 1/53 Lorraine Street, Peakhurst Business Centre, Peakhurst NSW 2210, Australia Tel: +61 - 1300 131516 Fax: +61 - 1300 131986 Email: [email protected] Website: www.palintest.com.au Palintest China Room 1601, Kun Tai International Mansion, 12B Chao Yang District, Beijing, 100020, PRC Tel: +86-10 5126 1868 - 809 Fax: +86-10 58790155 E.mail - [email protected] Website - www.palintest.cn Technical Specifications Instrument Type Dual wavelength, direct-reading colourimeter Optics Palintest dual LED light source optical system with narrow band wavelength filters and photodetectors Wavelengths 530 nm Wavelength Tolerance ± 2nm Filter Bandwidth 10nm LCD Display 128 x 64 pixel screen Instrument Operating Temperature Range 0 to 50°C Test Cells 25 mm diameter tubes Blank/Zero setting Held in memory or reset for each reading Power Supply 2 x 1.5V ‘AA’ batteries. Auto switch-off setting. Size 150 x 65 x 40 mm Weight 200g (including batteries) The new Palintest Chlorometer Duo offers a new dimension in chlorine testing. Used in conjunction with the DPD standard method developed by Palintest, it provides a level of simplicity and accuracy unrivalled in a portable hand-held instrument. Features Tests for Chlorine (DPD) 0.01 - 5 mg/l, Chlorine HR, 1 - 250 mg/l) Robust, Waterproof, IP 67 Rating Available in hard or soft carry case Easy to use (4 intuitive buttons) Ideal for routine water monitoring Compact Range Instrument Narrow band wavelength filters, enhanced performance Language Free, Universal symbol set Large backlit Graphics Display Screen Longer cell pathlength, excellent resolution at low concentrations
Transcript
Page 1: Chlorometer Duo - Aquago Chemchek Group NZ Ltd....Tel: +86-10 5126 1868 - 809 Fax: +86-10 58790155 E.mail - fred.fan@palintest.com Website - Technical Specifications Instrument Type

Chlorometer Duo

Palintest LtdPalintest House, Kingsway, Team Valley,Gateshead, Tyne & Wear, NE11 0NS, EnglandTel: +44 (0) 191 491 0808Fax: +44 (0) 191 482 5372Email: [email protected]: www.palintest.com

Palintest USA21 Kenton Lands Road, Erlanger,Kentucky 41018, USATel: (859) 341 7423 Toll Free: 800 835 9629Fax: (859) 341 2106Email: [email protected]: www.palintestusa.com

Palintest Australia/Asia Pacific1/53 Lorraine Street,Peakhurst Business Centre,Peakhurst NSW 2210, AustraliaTel: +61 - 1300 131516 Fax: +61 - 1300 131986Email: [email protected]: www.palintest.com.au

Palintest ChinaRoom 1601, Kun Tai International Mansion, 12B Chao Yang District, Beijing, 100020, PRCTel: +86-10 5126 1868 - 809 Fax: +86-10 58790155E.mail - [email protected] - www.palintest.cn

Technical SpecificationsInstrument Type Dual wavelength, direct-reading colourimeter

Optics Palintest dual LED light source optical system with narrow band wavelength filters and photodetectors

Wavelengths 530 nm

Wavelength Tolerance

± 2nm

Filter Bandwidth 10nm

LCD Display 128 x 64 pixel screen

Instrument Operating Temperature Range

0 to 50°C

Test Cells 25 mm diameter tubes

Blank/Zero setting Held in memory or reset for each reading

Power Supply 2 x 1.5V ‘AA’ batteries. Auto switch-off setting.

Size 150 x 65 x 40 mm

Weight 200g (including batteries)

The new Palintest Chlorometer Duo offers a new dimension in chlorine testing. Used in conjunction with the DPD standard method developed by Palintest, it provides a level of simplicity and accuracy unrivalled in a portable hand-held instrument.

Features

• Tests for Chlorine (DPD) 0.01 - 5 mg/l,

Chlorine HR, 1 - 250 mg/l)

• Robust, Waterproof, IP 67 Rating

• Available in hard or soft carry case

• Easy to use (4 intuitive buttons)

• Ideal for routine water monitoring

Compact Range

Instrument

• Narrow band wavelength filters,

enhanced performance

• Language Free, Universal symbol set

• Large backlit Graphics Display Screen

• Longer cell pathlength, excellent

resolution at low concentrations

Email User
TextBox
ChemChek NZ
Email User
TextBox
ChemChek NZ PH (09) 275-5019 FAX (09) 921-2868 Email: [email protected]
Page 2: Chlorometer Duo - Aquago Chemchek Group NZ Ltd....Tel: +86-10 5126 1868 - 809 Fax: +86-10 58790155 E.mail - fred.fan@palintest.com Website - Technical Specifications Instrument Type

Kit Options

Hard Carry Case

Chlorometer Duo, Chlorometer Duo Instructions, 4 Crushing Rods, 4 x Photometer Tubes, Test Tube Brush

Reagents:Chlorine (DPD 1), Chlorine (DPD 3), Chlorine HR and Acidifying GP 4 Cartons (100 reagents per carton)

Soft Carry Case

Chlorometer Duo, Chlorometer Duo Instructions, 4 Crushing Rods, 2 x Photometer Tubes, Test Tube Brush

Reagents:

Chlorine (DPD 1), Chlorine (DPD 3), Chlorine HR and Acidifying GP

1 Carton (20 reagents per parameter)

Find out more about our new Compact Range of Photometers

www.palintest.com

Ordering CodesSoft Carry Case Kit - PTS 027

Hard Carry Case Kit - PTH 027

Check Standards - PTC 027

PM - 50 Tests, AP - 250 TestsDPD 1 tablet pack - PM 011, AP 011DPD 3 tablet pack - AP 031/1Chlorine HR tablet pack - PM 162, AP 162

Replacement Photometer Tubes (x5) - PT 555Crushing Rods (x10) - PT 502

Reagents

TEST RANGE(mg/l)

REAGENT PACKS (50 TESTS)

REAGENT PACKS (250 TESTS)

DPD 1 Tablets 0.01 -5.0 PM 011 AP 011

DPD 3 Tablets 0.01 -5.0 - AP 031/1

Chlorine HR Tablets 1 - 250 PM 162 AP 162

Acidifying GP AT 052


Recommended