+ All Categories
Home > Documents > Christian Pinzon, ABB Power Grids The power of one ... · Christian Pinzon, ABB Power Grids ......

Christian Pinzon, ABB Power Grids The power of one ... · Christian Pinzon, ABB Power Grids ......

Date post: 23-Apr-2018
Category:
Upload: nguyennhi
View: 228 times
Download: 1 times
Share this document with a friend
25
© ABB | Slide 1 4CAE000262 The power of one solution for Christian Pinzon, ABB Power Grids distributed busbar protection What’s new in Relion ® REB500 version 8? June 30, 2016
Transcript

© ABB| Slide 1 4CAE000262

The power of one solution forChristian Pinzon, ABB Power Grids

distributed busbar protectionWhat’s new in Relion® REB500 version 8?

June 30, 2016

© ABB| Slide 2 4CAE000262

The power of onePresenter

Christian PinzonGlobal Product Manager Relion® REB500

June 30, 2016

© ABB| Slide 3 4CAE000262

Agenda

1. Relion® busbar protection portfolio2. Relion® REB500 4th evolution3. Tools4. New features5. System deployment6. Summary

The power of one solution for distributed busbar protection

June 30, 2016

© ABB| Slide 4 4CAE000262

Relion® REB500 4th evolutionProtection busbar portfolio

June 30, 2016

© ABB| Slide 5 4CAE000262

Relion® REB500 4th evolutionDistributed busbar protection

Distributed concept One central unit Field oriented bay units

Features

June 30, 2016

© ABB| Slide 6 4CAE000262

Relion® REB500 4th evolutionVersion 8

20002015

1995

4th GenerationRelion®

Enabling communicationIEC 61850-8-1 Edition 2

2th GenerationStandardized

3th GenerationCommon look & feelConfigurator order codeIEC 61850-8-1 Edition 1

2005

1st GenerationModular

June 30, 2016

© ABB| Slide 7 4CAE000262

Relion® REB500 4th evolutionWhat’s new?

Sub cycle busbar protection Breaker failure protection End fault protection Disturbance recorder Line backup protection IEC 61850-8-1 GOOSE WebHMI

Features

June 30, 2016

© ABB| Slide 8 4CAE000262

Relion® REB500 4th evolutionProduct portfolio – central and bay units

June 30, 2016

© ABB| Slide 9 4CAE000262

Relion® REB500 4th evolutionProduct portfolio – Bay unit

Size 6U ½ 19" 6U ½ 19" 6U ½ 19"

CT / VT 4 / 0 4 / 0 5 / 5

I/O default 21 / 19 21 / 19 21 / 19

Bay Protection - - ●

GOOSE ● ● ●

June 30, 2016

© ABB| Slide 10 4CAE000262

Relion® REB500 4th evolutionTools

* PCM600 2.7 or higher** ConnPack via Update Manager *** HMI500 via ABB Software Library - Link

Product SDM600 PCM600 HMI500

Use case - - Operate ConfigurateUser access management ● ● ● -

Monitor event list ● ● ● -

Monitor disturbance recorder ● ● ● -

Read / Write set file - ● ● -

Online test - - ● -

Online single line - - ● -

Parameter setting - - ● ●

I/O configuration - - ● ●

Create report - - ● ●

Application configuration - - - ●

June 30, 2016

© ABB| Slide 11 4CAE000262

Relion® REB500 4th evolutionPCM600 ConnPack tool

*PCM600 2.7 or higher

June 30, 2016

© ABB| Slide 12 4CAE000262

Relion® REB500 4th evolutionPCM600 tool

*PCM600 2.7 or higher

June 30, 2016

© ABB| Slide 13 4CAE000262

Relion® REB500 4th evolutionHMI500 single line diagram tool

June 30, 2016

© ABB| Slide 14 4CAE000262

Relion® REB500 4th evolution featuresWebHMI

User access control

June 30, 2016

© ABB| Slide 15 4CAE000262

Relion® REB500 4th evolution featuresWebHMI

Extensive WebHMI

Remotely gain insight into your operations via standard internet browser

Protection monitoring

June 30, 2016

© ABB| Slide 16 4CAE000262

Relion® REB500 4th evolution featuresWebHMI

Feature Single line diagram Event list Differential current

Benefit Easy access Usable on tablet

June 30, 2016

© ABB| Slide 17 4CAE000262

Relion® REB500 4th evolution featuresLine back up protection

Distance protection Based on REL316*4

Various current function

June 30, 2016

© ABB| Slide 18 4CAE000262

Relion® REB500 4th evolution featuresLine back up protection details

Feature Zone 1 - 4

Power swing blocking

Switch-onto-fault

Voltage circuit supervision

PUTT, POTT

Benefit Multi object

Reduced investment

June 30, 2016

© ABB| Slide 19 4CAE000262

Relion® REB500 4th evolution featuresDifferential disturbance recorder

Feature Differential current per phase

Restraint current per phase

Benefit Easy access

No manual data merging

(1) normal(2) extern(3) internal

1 2 3

June 30, 2016

© ABB| Slide 20 4CAE000262

Relion® REB500 4th evolution featuresGOOSE

Feature Receive Start for BFP

I/O configuration based on SCD

Benefit Reduced binary input

Reduced copper wiring

No addition communication

Efficient input assignment

June 30, 2016

© ABB| Slide 21 4CAE000262

Relion® REB500 4th evolution featuresLocal display

Feature Direct interaction with IEDs without tools

Local language support

Status indication LEDs

Measurements

Hot Pluggable

Benefit Effective interaction

No restart of IED

June 30, 2016

© ABB| Slide 22 4CAE000262

Relion® REB500 4th evolutionSystem deployment

Station communication Optical Ethernet

IEC 61850-8-1 Ed.1/Ed.2

PRP

IEC 60870-5-103

Remote HMIs

Central Unit <> Bay Unit Optical Ethernet

Up to 2000 meter

Separate network

ABB AFS677 switch

To station

To field

June 30, 2016

© ABB| Slide 23 4CAE000262

REB650 REB670 REB500 REB500sys

High impedance Low impedance

Relion® REB500 4th evolutionProtection busbar portfolio

Centralized Distributed

3BB

.2B

B .

1BB

.

Busbar protection Station protection

June 30, 2016

© ABB| Slide 24 4CAE000262

The power of one solution for distributed busbarprotection. Relion® REB500

Presentation and recordings will be available on www.abb.com/protection-control

For more information please contact your local ABB Sales Team viawww.abb.com/protection-control

Thanks for joining us

June 30, 2016

© ABB| Slide 25 4CAE000262June 30, 2016


Recommended