HARDWARE INTERFACE MANUAL ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules ChromaFlex www.atxnetworks.com www.atx.com DISCONTINUED
Transcript
Page 1: ChromaFlex - ATX Networks

HARDWARE INTERFACE MANUAL

ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules

ChromaFlex

www.atxnetworks.comwww.atx.com

DISCONTINUED

Page 2: ChromaFlex - ATX Networks

Products or features contained herein may be covered by one or more U.S. or foreign patents. Other non-ATX product and company names in this manual are the property of their respective companies.

Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments or correct omissions. Specifications subject to change without notice.

Page 3: ChromaFlex - ATX Networks

ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface Manual iiiATX Confidential & Proprietary

TABLE OF CONTENTS

1. PRODUCT INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

2. UNPACKING & INSPECTING A NEW UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1

2.1 What To Do About Physical Damage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12.2 What To Do About Concealed Damage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12.3 How To Return Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1

3. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1

4. BLOCK DIAGRAM & OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1

5. FRONT PANEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1

5.1 Front Panel Illustration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15.2 Table of Front Panel Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15.3 Alarm Status Indicators (CF-QRRX-S) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2

6. MODULE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1

7. MODULE CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1

7.1 RF Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-17.2 Optical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2

8. MODULE SET-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1

8.1 Set-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1

9. TROUBLESHOOTING THE CF-QRRX RETURN RECEIVER MODULE . . . . . . . . . . . 9-1

10. SERVICE & SUPPORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-1

10.1 Contact ATX Networks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-110.2 Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-1

Page 4: ChromaFlex - ATX Networks

iv ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface ManualATX Confidential & Proprietary

This page intentionally left blank.

Page 5: ChromaFlex - ATX Networks

PRODUCT INTRODUCTION

ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface Manual 1-1ATX Confidential & Proprietary

PRODUCT INTRODUCTION

1. Product IntroductionThe ChromaFlex CF-QRRX quad return path receiver is a high density, single-slot module for the ChromaFlex chassis. Each receiver module incorporates four individual receivers and a wide RF output range. The CF-QRRX is available in a standard sensitivity version for node analog return applications or as a high sensitivity, very low noise version ideal for RFoG applications, utilizing very low optical input levels. Up to eight modules can be installed into the ChromaFlex chassis providing 32 return path receiver RF segments in two rack units (2RU) of space. Features of the CF-QRRX receiver include:

• Low noise option with <1.5pA/√Hz and operating range to -30 dBm.• Optical automatic gain control.• Variable attenuation control and plug-in output pad for maximizing levels and performance.• High gain and wide range of RF output level.• Integrated optical express port options including xPON. • Integrated optical DMux options to support DWDM return transmitters.• Front panel visual status indicators.• Set-up and manage via SNMP, CLI, web GUI, local craft port.

The CF-QRRX may include optional integrated optical filters to eliminate external connections and additional rack space consumption. Options include 4-way DMux filters to support DWDM return path transmitters or express ports for daisy chaining multiple receivers or interfacing with xPON bi-direction OLT ports.

CHAPTER 1:

Page 6: ChromaFlex - ATX Networks

PRODUCT INTRODUCTION

1-2 ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface ManualATX Confidential & Proprietary

CHAPTER 1:

This page intentionally left blank.

Page 7: ChromaFlex - ATX Networks

UNPACKING & INSPECTING A NEW UNIT

ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface Manual 2-1ATX Confidential & Proprietary

UNPACKING & INSPECTING A NEW UNIT

2. Unpacking & Inspecting a New UnitBefore shipment, ATX inspects and packs all the essential items carefully. Nevertheless, damage may occur during shipment. The carrier assumes full responsibility for a safe delivery of the equipment.

1. Inspect the package for any physical damage.2. Open the package.3. Remove any packing material.4. Inspect the unit for any physical damage.5. Shake the unit with care, paying attention to any rattling loose parts that may suggest a concealed damage (some

noise due to moving cables is normal).6. Check for any missing accessories.

When any damage is noticed to the merchandise, please notify customer service (see Service & Support section) and file a claim with the carrier as noted below.

2.1 What To Do About Physical DamageRecord any evidence of physical damage or loss on the freight bill or receipt and have the carrier’s agent sign it. If you fail to do so, the carrier may refuse to honor the damage claim. The carrier will supply you with any forms required to file such a claim.

2.2 What To Do About Concealed DamageDamage which is not apparent until the unit has been unpacked is considered concealed damage. The contents may have been damaged due to rough handling even if there is no external evidence. If you should notice damage upon unpacking the unit you should make a written request for inspection by the carrier’s agent within 10 days of the delivery date. Afterwards file a claim with the carrier.

2.3 How To Return EquipmentCall customer service (see Service & Support section) for a Return Materials Authorization (RMA) number. You will need the unit’s serial number, description of the problem, and some shipping information. We must receive the unit within thirty (30) days from the date a RMA number is issued. If for any reason, you want to ship the unit 30 days after the RMA number has been issued, you must obtain a new RMA number by calling customer service. Units received without an RMA number or one with an expired RMA number will not be accepted by our receiving department.

CHAPTER 2:

Page 8: ChromaFlex - ATX Networks

UNPACKING & INSPECTING A NEW UNIT

2-2 ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface ManualATX Confidential & Proprietary

CHAPTER 2:

This page intentionally left blank.

Page 9: ChromaFlex - ATX Networks

SPECIFICATIONS

ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface Manual 3-1ATX Confidential & Proprietary

SPECIFICATIONS

3. Specifications

CHAPTER 3:

SPECIFICATIONSCF-QRRX-S*-* CF-QRRX-H*-* CF-QRRX-**-*DS

APPLICATION Standard Sensitivity High Sensitivity (RFoG) Dual SwitchOPTICAL PARAMETER

OPTICAL INPUT RANGE(1) +3 to -20 dBm -10 to -28 dBmNo Impact to Optical

PerformanceWAVELENGTH 1270-1620nmRESPONSIVITY 0.85A/W @ 1310nm / 0.95A/W @ 1550nm

EQUIVALENT INPUT NOISE (Typ) < 3 pA/√Hz < 1.5 pA/√HzNo Impact to Optical

PerformanceOPTICAL RETURN LOSS > 50 dBOPTICAL INTERFACES LC/APCRF PARAMETERRF PASSBAND 5-204 MHz 5-85 MHz No Impact to RF PassbandRF OUTPUT LEVEL(2)(3) 30 dBmV 29 dBmVMAXIMUM RF OUTPUT LEVEL 50 dBmV (Composite) 49 dBmV (Composite)RF ATTENUATION RANGE 0-30 dB in 0.5 dB StepsOPTICAL AGC RANGE(4) +3 to -12 dBm -10 to -25 dBm No Impact to AGCSWITCHING TIME n/a <10 μsSWITCHING THRESHOLD n/a 0 to -23 dBmRF ISOLATION(5) > 50 dB (5-204 MHz) > 50 dB (5-85 MHz) No Impact to RF IsolationRETURN LOSS > 16 dBFREQUENCY RESPONSE ± 1 dBRF TEST POINT (Front Panel) -20 +/- 1.0 dBMANAGEMENT SNMP v2c, CLI, Web GUI, TelnetELECTRICALPOWER CONSUMPTION 15WPHYSICALDIMENSIONS ChromaFlex One-slot Module, 1.7”H x 3.7”W x 14.4”D (4.3H x 9.3W x 36.5D cm)WEIGHT 1.3 lbs (0.6 kg)ENVIRONMENTALOPERATING TEMPERATURE 0°C to +50°C (+32°F to +122°F)STORAGE TEMPERATURE -40°C to +85°C (-40°F to +185°F)HUMIDITY 5-85% Non-condensing NOTES: (1) Optional express port will increase input power range by 1 dB. Optional DMux will increase input power range by 1.5 dB. (2) Standard receiver at -12 dBm optical input, 10% OMI on transmitter, 0 dB internal attenuation, 0 dB output plug-in pad. Level will be reduced 2 dB if express ports are present & 3 dB if DMux is present. (3) High sensitivity receiver at -20 dBm optical input, 30% OMI on transmitter, 0 dB internal attenuation, 0 dB output plug-in pad. Level will be reduced by 2 dB if express ports are present & 3 dB if DMux is present. (4) Automatic RF attenuation change based on received optical levels (2:1 RF:Opt). (5) Measured with same optical input level on all four receivers.

Page 10: ChromaFlex - ATX Networks

SPECIFICATIONS

3-2 ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface ManualATX Confidential & Proprietary

This page intentionally left blank.

CHAPTER 3:

Page 11: ChromaFlex - ATX Networks

BLOCK DIAGRAM & OPERATION

ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface Manual 4-1ATX Confidential & Proprietary

BLOCK DIAGRAM & OPERATION

4. Block Diagram & OperationThe following block diagrams depict the RF and optical signal flow through the CF-QRRX quad return receiver module with optional optical express ports and DWDM demultiplexer.

CF-QRRX Quad Return Receiver Module Block Diagram with Optional Express Ports

CF-QRRX Quad Return Receiver Module Block Diagram with Optional DMux

The CF-QRRX quad return receiver module has four independent receivers in a single module. The optical and RF signal flow is the same for each receiver. An optical signal in the 1270-1620nm range is connected to the front panel optical input LC connector. If the receiver was ordered with an optional express port for RFoG and PON OLT combining, only the 1610nm RFoG return signal is passed to the receiver and the specified reflect band passes through the express port LC connector. The same applies to CF-QRRX receivers ordered with an integrated DWDM DMux filter. The integrated DMux accepts four wavelengths on a single optical input connector and demultiplexes a single wavelength to each of the four receivers.The desired optical signal first passes to an optical detector where the RF signal is removed from the optical signal carrier. The detector also has an optical monitor which is fed to a microcontroller which provides control to the variable RF attenuator when operated in the AGC mode. The RF output of the photodetector then passes through a first stage of amplification. The output of the amplifier is connected to the variable RF attenuator which can be manually adjusted through the ChromaFlex local craft interface via; the hand-held display controller, GUI interface or CLI; or remotely via SNMP, CLI or the web-based GUI. The RF attenuator has a 30 dB range which may be adjusted in 0.5 dB increments. When operated in

CHAPTER 4:

Page 12: ChromaFlex - ATX Networks

BLOCK DIAGRAM & OPERATION

4-2 ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface ManualATX Confidential & Proprietary

the “AGC” mode, the variable RF attenuator is controlled by the microprocessor for optimum performance. When the optical input to the photodector is -12 dBm (model CF-QRRX-S after any internal optional filters) the RF attenuator is set to 0 dB. For every 0.5 dB of optical input power above -12 dBm the RF attenuation is increased 1 dB with a range up to +3 dBm. The total optical range of the “AGC” is 15 dB optical or 30 dB RF attenuation. If the input level is less than -12 dBm the overall return link noise performance may be degraded. The RF signal then passes through a second amplifier and plug-in pad attenuator. The plug-in attenuator allows you to adjust the RF output level independent of the variable attenuator. The CF-QRRX is shipped with a 9 dB pad installed which yields approximately a 30 dBmV output level when operated in the AGC mode over an optical input range of -12 dBm to +3 dBm. The pad can be adjusted to 0 for approximately 40 dBmV output or increased for lower RF output levels. The plug-in pad will have no effect on the performance of the receiver as it is post active devices.

CHAPTER 4:

Page 13: ChromaFlex - ATX Networks

FRONT PANEL

ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface Manual 5-1ATX Confidential & Proprietary

FRONT PANEL

5. Front Panel

5.1 Front Panel IllustrationThe following diagram and table depicts the features of the CF-QRRX return receiver module front panel.

5.2 Table of Front Panel FeaturesModule Extraction Lever Lever to assist in removing the module from the chassis

backplane connector.

Module Retaining Screws Secures the module to the chassis.

Module Handle Utilized to insert and remove the module.

RF Test Point -20 dB sample of the RF output.

RF Test Point Selector Switch Selects the receiver (1 to 4) for the RF test point.

Optical Input LC/APC Connector (IN) Optical input signal connection.

(Optional) Express Port (EP) Utilized to extract or combine additional optical signals to or from other equipment. 1260-1620nm. Important Note: be certain not to combine same channels.

Status Alarm LED Visual indicator of module temperature alarm.

Receiver Optical Alarm LEDs Visual optical power alarm status indicators for each of the four receivers.

CHAPTER 5:

Page 14: ChromaFlex - ATX Networks

FRONT PANEL

5-2 ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface ManualATX Confidential & Proprietary

5.3 Alarm Status Indicators (CF-QRRX-S)LED Function Value

STATUS Module Temperature Green = NormalAmber = Minor Temp AlarmRed = Major Temp Alarm

1,2,3,4 One LED for each receiver 1 through 4.Monitors the optical input to each receiver.

Green = NormalAmber = Minor Alarm +/- 2 dB Out of RangeRed = Major Alarm +/- 3 dB Out of Range

CHAPTER 5:

Page 15: ChromaFlex - ATX Networks

MODULE INSTALLATION

ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface Manual 6-1ATX Confidential & Proprietary

MODULE INSTALLATION

6. Module InstallationThe CF-QQRX return receiver module occupies a single ChromaFlex chassis module slot. The modules may be inserted or removed while the chassis is powered without interrupting other operational modules in the chassis. The following module installation procedures assume the chassis is installed and powered following the instructions in the ChromaFlex Chassis Hardware Interface Manual.

1. Align the module into the desired slot opening in the ChromaFlex chassis.2. Using the handle push the module into the slot with even pressure until the module is mated with the chassis

mid-plane connector. 3. Press the module extraction levers downward against the module face.4. Tighten the two module retaining screws until snug in an even manner.5. The module Status LEDs should now be lit green and the four optical power LEDs red if an optical input has not

already been connected to the module. Note, each LED will cycle through all colors during a power up cycle.

CHAPTER 6:

Page 16: ChromaFlex - ATX Networks

MODULE INSTALLATION

6-2 ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface ManualATX Confidential & Proprietary

CHAPTER 6:

This page intentionally left blank.

Page 17: ChromaFlex - ATX Networks

MODULE CONNECTIONS

ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface Manual 7-1ATX Confidential & Proprietary

MODULE CONNECTIONS

7. Module ConnectionsThe following describes the initial RF and optical connections to the chassis and module.

7.1 RF ConnectionsRF connections are made at the back of the ChromaFlex chassis. Each module has four independent RF output connections, one per receiver.

RF CONNECTIONS FOR APPLICATION SLOTS 1 THRU 8. FOUR CONNECTORS PER SLOT

The following table and diagram shows the corresponding RF connectors to module slots for the CF-QRRX receiver module.

CHAPTER 7:

Example connections for a CF-QRRX populated in slot 1 & 2.

1-1 Output 11-2 Output 21-3 Output 31-4 Output 42-1 Output 12-2 Output 22-3 Output 32-4 Output 43-1 Output 13-2 Output 23-3 Output 33-4 Output 44-1 Output 14-2 Output 24-3 Output 34-4 Output 45-1 Output 15-2 Output 25-3 Output 35-4 Output 46-1 Output 16-2 Output 26-3 Output 36-4 Output 47-1 Output 17-2 Output 27-3 Output 37-4 Output 48-1 Output 18-2 Output 28-3 Output 38-4 Output 4

8

QRRX

3

4

5

6

7

Module Slot

Rear Panel Connector

1

2

Page 18: ChromaFlex - ATX Networks

MODULE CONNECTIONS

7-2 ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface ManualATX Confi dential & Proprietary

7.2 Optical ConnectionsThe CF-QRRX return receiver has four optical input ports, one for each receiver, and may have four optional optical express ports which may fi lter or refl ect additional optical signals to other equipment. Please follow your specifi c design schematic for interconnecting additional equipment while paying attention to the optical levels specifi ed for your application.

Important Note: Always clean and inspect optical connectors prior to making a connection to the CF-QRRX optical ports. Never look into an optical connector when a signal is present.

1. Ensure the optical LC/APC connector is clean prior to connecting to the CF-QRRX ports. Check the optical level with a power meter to be certain it is within the operational range of the receiver and closely matches your network design. If a discrepancy exists, troubleshoot the optical network path before proceeding.

2. Once the levels are verifi ed, connect each cleaned connector to the associated receiver optical input port. You should observe the optical input LED change from Red to Green if a signal is present.

3. If utilizing the optional express ports, connect a power meter to the express port with a clean LC/APC jumper and verify the level of the desired optical signal.

CHAPTER 7:

Page 19: ChromaFlex - ATX Networks

MODULE SET-UP

ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface Manual 8-1ATX Confidential & Proprietary

MODULE SET-UP

8. Module Set-upPlease refer to the instructions below and the ChromaFlex Chassis Operation Manual for details on configuring the CF-QRRX return receiver module set-up for optimal performance with the hand-held display or GUI.

8.1 Set-up1. Identify the CF-QRRX unit at the corresponding slot location.2. Connect the input port (labeled IN) utilizing a good quality clean LC/APC connector to the next device or fiber cable

per your specific design schematic drawing. 3. Set Mode to AGC (Default) or MGC.4. If AGC mode is used, the unit will optimize itself for optimal gain depending on the optical input level. (Refer to section

4.)5. If set to MGC, first measure your optical input level. Add 2 dB of RF Attn to every 1 dB of power above -12 dBm (CF-

QRRX-S) or -25 dBm (CF-QRRX-H). Example: optical input = -7 dBm equals a 5 dB delta between -7 dBm and -12 dBm. Set Attn value to 10 dB.

CHAPTER 8:

Page 20: ChromaFlex - ATX Networks

MODULE SET-UP

8-2 ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface ManualATX Confidential & Proprietary

CHAPTER 8:

This page intentionally left blank.

Page 21: ChromaFlex - ATX Networks

TROUBLESHOOTING THE CF-QRRX RETURN RECEIVER MODULE

ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface Manual 9-1ATX Confidential & Proprietary

TROUBLESHOOTING THE CF-QRRX RETURN RECEIVER MODULE

9. Troubleshooting the CF-QRRX Return Receiver ModuleCondition Steps to CheckPower LED OFF (AC) 1. Check if Power Cable is plugged in and Power Switch is in ON position.

2. Verify AC Outlet is Functional and confirm fuse on the AC feed is fine, replacing it if necessary.3. Look for other signs of life in unit like running fan, LCD display etc.

Power LED OFF (DC) 1. Verify DC Feed is active and fuse is intact on fuse panel.2. Verify DC Feed is not reversed.3. Look for other signs of life in unit like running fan, LCD display etc.

Optical Input LED is Amber or Red 1. Check Optical input level.2. Check for dirty optical connectors.

No RF Output is Present 1. Check Optical input level.2. Check if output attenuator is present.3. Check attn. setting if in MGC mode.

Communication Issue with Unit 1. Please confirm set-up is as described in the User Interface document.2. If problem persists, please contact ATX for further help.

CHAPTER 9:

Page 22: ChromaFlex - ATX Networks

TROUBLESHOOTING THE CF-QRRX RETURN RECEIVER MODULE

9-2 ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface ManualATX Confidential & Proprietary

This page intentionally left blank.

CHAPTER 9:

Page 23: ChromaFlex - ATX Networks

SERVICE & SUPPORT

ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules – Hardware Interface Manual 10-1ATX Confidential & Proprietary

SERVICE & SUPPORT

10. Service & Support

10.1 Contact ATX NetworksPlease contact ATX Technical Support for assistance with any ATX products.

TECHNICAL SUPPORTTel: 289.204.7800 – press 1Toll-Free: 866.YOUR.ATX (866.968.7289) USA & Canada onlyEmail: [email protected]

SALES ASSISTANCETel: 289.204.7800 – press 2Toll-Free: 866.YOUR.ATX (866.968.7289) USA & Canada onlyEmail: [email protected]

FOR HELP WITH AN EXISTING ORDERTel: 289.204.7800 – press 3Toll-Free: 866.YOUR.ATX (866.968.7289) USA & Canada onlyEmail: [email protected]: www.atx.com

10.2 Warranty InformationAll of ATX Networks’ products have a 1-year warranty that covers manufacturer’s defects or failures.

CHAPTER 10:

Page 24: ChromaFlex - ATX Networks

ISO9001:15

REGISTERED

www.atx.com

Rev. 01/20 (ANW1222)

ATX NetworksTel: 289.204.7800 | Toll-Free: 866.YOUR.ATX (866.968.7289) | [email protected]

© 2020 by ATX Networks Corp. and its affiliates (collectively “ATX Networks Corp.”). All rights reserved. This material may not be published, broadcast, rewritten, or redistributed. Information in this document is subject to change without notice.