+ All Categories
Home > Documents > Circular Sedimentation (Settling) Tank - Batch Discharges ...

Circular Sedimentation (Settling) Tank - Batch Discharges ...

Date post: 18-Dec-2021
Category:
Upload: others
View: 7 times
Download: 0 times
Share this document with a friend
3
SEDIMENT SAMPLE TAP TOTALIZING NON-RESETTABLE FLOW METER CONSTRUCTION DEWATERING WASTEWATER SEDIMENT FM Circular Sedimentation (Settling) Tank - Batch Discharges Pumped Discharges - Step 1 - Tank Filling Scale: NTS ROPE OR CHAIN TO SUSPEND PUMP HOSE OR FLEXIBLE PIPING MATERIAL LOCAL SANITARY SEWER Sewer clean-out or manhole discharge location as approved by local sewer agency. 1512_5135m_2-ACircularSedTank-Pumped_Stp1-tankFilling.ai Submersible pump to remain outside of tank when filling. Lower decant valve to remain closed at all times. Only to be used for final clean rinse of tank prior to return to rental company. NOTE: All sediments need to be properly removed and shipped offsite.
Transcript
Page 1: Circular Sedimentation (Settling) Tank - Batch Discharges ...

SEDIMENT

SAMPLE TAP

TOTALIZINGNON-RESETTABLEFLOW METER

CONSTRUCTIONDEWATERINGWASTEWATER

SEDIMENTFM

Circular Sedimentation (Settling) Tank - Batch DischargesPumped Discharges - Step 1 - Tank Filling

Scale: NTS

ROPE OR CHAINTO SUSPEND PUMP

HOSE OR FLEXIBLE PIPING MATERIAL

LOCAL SANITARYSEWER

Sewer clean-out or manhole discharge location as approvedby local sewer agency.

1512_5135m_2-ACircularSedTank-Pumped_Stp1-tankFilling.ai

Submersible pump to remain outside oftank when �lling.

Lower decant valve to remain closed at all times.

Only to be used for �nal clean rinse of tank prior to return to

rental company.

NOTE: All sediments need to be properly removed and

shipped o�site.

Page 2: Circular Sedimentation (Settling) Tank - Batch Discharges ...

START STOP

1211

109

8

7 65

43

2

1 11

109

8

7 65

43

12

2

1

SEDIMENTSEDIMENT

Circular Sedimentation (Settling) Tank - Batch DischargesPumped Discharges - Step 2 - Quiescent (Undisturbed) Settling

Scale: NTS

LOCAL SANITARYSEWER

One hour(60 minutes) of quiescent(undisturbed) settling

CLARIFIED (SETTLED) CONSTRUCTIONDEWATERING WASTEWATER

SAMPLE TAP

TOTALIZINGNON-RESETTABLEFLOW METER

FM

ROPE OR CHAINTO SUSPEND PUMP

HOSE OR FLEXIBLE PIPING MATERIAL

LOCAL SANITARYSEWER

Sewer clean-out or manhole discharge location as approvedby local sewer agency.

Submersible pump to remain outside oftank when �lling.

Check sediment level (sticks or PVC pipe segments work well).

Lower decant valve to remain closed at all times.

Only to be used for �nal clean rinse of tank prior to return to

rental company.

NOTE: All sediments need to be properly removed and

shipped o�site.

1512_5135m_2-BCircularSedTank-Pumped_Stp2-Quiescent.ai

Page 3: Circular Sedimentation (Settling) Tank - Batch Discharges ...

SEDIMENTSEDIMENT

Scale: NTS

LOCAL SANITARYSEWER

SAMPLE TAP

TOTALIZINGNON-RESETTABLEFLOW METER

FM

ROPE OR CHAINTO SUSPEND PUMP

HOSE OR FLEXIBLE PIPING MATERIAL

LOCAL SANITARYSEWER

Sewer clean-out or manhole discharge location as approvedby local sewer agency.

CLARIFIED (SETTLED)CONSTRUCTION

DEWATERING WASTEWATER

STARTING WASTEWATER ELEVATION

Minimum one-foot (1’)elevation of pump intake

above sediment

Circular Sedimentation (Settling) Tank - Batch DischargesPumped Discharges - Step 3 - Pumped Discharge of

Clari�ed Wastewater

Lower decant valve to remain closed at all times.

Only to be used for �nal clean rinse of tank prior to return to

rental company.

NOTE: All sediments need to be properly removed and

shipped o�site.

1512_5135m_2-CCircularSedTank-Pumped_Stp3-Discharge.ai


Recommended