PARKING LOT
(40 STALLS)
FENCE - DOG PARK
PARKING LOT
(10 STALLS)
CULTURAL
AREA
RO
AD
R
.O
.W
NATURAL
AREA
SECONDARY TRAIL
PARKING LOT
(5 STALLS)
& BUS PARKING
EXISTING CHIEF
WHITECAP STATUE
EXISTING FENCE
TO REMAIN
EXISTING ROADWAY
TO BE EXTENDED TO
CENTRAL PARKING LOT
RIVERSIDE COUNTRY CLUB
B
I
R
C
H
W
O
O
D
H
E
I
G
H
T
S
MEEWASIN TRANS
CANADA TRAIL
DOG PARK TRAIL
W
RE-VEGETATE AS
REQUIRED
(NATURALIZED AREA)
W
EXISTING TRAIL
TO BE UPGRADED
FLOOD PLAIN
DOG PARK
(80 acres)
CHAINLINK FENCE
S
A
S
K
A
T
C
H
E
W
A
N
C
R
E
S
C
E
N
T
INTERPRETIVE
AREA
HIS
TO
RIC
AL A
RE
A
W
MEEWASIN VALLEY AUTHORITYCHIEF WHITECAP PARK
ISSUED FOR CLIENT REVIEW MARCH 27, 2018Project Number: 113154640
ORI
GIN
AL S
HEET
- AN
SI D
V:\1
131\
activ
e\11
3154
640\
cad\
draw
ings
\lan
dsca
pe\p
roje
ct_d
wgs
\546
40l_d
_cov
r.dw
g20
18/0
3/28
12:
45 P
M By:
Cho
lodn
uik,
Kar
ri
LIST OF DRAWINGS
CITY OF SASKATOON
COVER SHEETCOVER SHEET AND LIST OF DRAWINGSC-1
LANDSCAPE PLANL-1DETAILSL-2DETAILSL-3
C-1
Drawing No.
N
IMAGEPROVIDED BY GOOGLE EARTH PRO
DETAILSL-4
LOOK OUT A
LOOK OUT B
LOOK OUT C
X X
X
X
X
X
X
XX
X
XX
XX
XX
XX
XX
X
265.
30
XX
XX
X
MATCH A-A
MATCH B-B
F
A
A
A
A
A
B
B
B
B
B
C
C
C
C
F
F
F
F
F
G
G
G
G
H
M
M
G
G
G
W
ww
ww
D
S
C
T
S
C
C
C
C
C
C
T
D
T
MATCH A-A
MATCH B-B
A
B
B
B
B
B
C
C
C
C
C
C
T
W
A
MATERIALS LIST
DESCRIPTIONKEY QTY.
B
2.4m CRUSHER DUST
PATH
3.0m CRUSHER DUST
PATH
BENCH - MEEWASIN/TRANS CANADA
TAIL MEEWASIN RUSTIC BENCH
PAIGE WIRE FENCE
3774 -
SQ. M.
8483 -
SQ. M.
13 -
EACH
1449 -
LIN. M.
C
F
2018 DETAIL / SPECIFICATION
SECTION 02511, DETAIL 02511-01
SECTION 02511, DETAIL 02511-01
G
6 -
EACH
SINGLE SWING PEDESTRIAN
GATE
H
84 -
LIN. M.
1.8m ht. CHAIN LINK FENCE
SECTION 02831
M
2 -
EACH
MAINTENANCE GATE
SECTION 02831
DRAWING L-2
DOG PARK WASTE DISPENSER
2 -
EACH
D
S
2 -
EACH
DOG PARK SIGN
PROVIDED BY THE CITY OF
SASKATOON
T
3 -
EACH
WASTE RECEPTACLE
W
2 -
EACH
WAY FINDING SIGN (LARGE)
ww
2 -
EACH
WAY FINDING SIGN (SMALL)
DRAWING L-2
DRAWING L-4
DRAWING L-4
DRAWING L-3
DRAWING L-3
Copyright ReservedThe Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to
The Copyrights to all designs and drawings are the property of
authorized by Stantec is forbidden.
Stantec without delay.
Stantec. Reproduction or use for any purpose other than that
Legend
Notes
Drawing No.
Scale
Revision
Title
Client/Project
Project No.
Sheet
of
Permit-SealChkd.Dwn. Dsgn. YY.MM.DD
File Name:
ByIssued Appd. YY.MM.DD1. FOR DEVELOPMENT REVIEW KC CP 16.03.172. ISSUED FOR CLIENT REVIEW KC AL 18.03.27
ByRevision Appd. YY.MM.DD
ORIGINAL SHEET - ANSI D
V:\1
131\
activ
e\11
3154
640\
cad\
draw
ings
\lan
dsca
pe\p
roje
ct_d
wgs
\546
40l_d
_site
.dw
g20
18/0
3/28
12:
12 P
M By:
Cho
lodn
uik,
Kar
ri
MEEWASIN VALLEY AUTHORITY
CHIEF WHITECAP PARK
Saskatoon, Saskatchewan
LANDSCAPE PLAN
113154640
L-1 2 5 0
www.stantec.comTel.
Stantec100-75 24th Street EastSaskatoon Saskatchewan S7K 0K3
306.667.2400
LAYOUT OF TRAIL, FENCE AND PLANTING IS SCHEMATIC.
EXACT LAYOUT TO BE DETERMINED ON SITE.
OFF - LEASH
DOG PARK
INTERPRETIVE
AREA
EXISTING
PARKING
LOT (46
STALLS)
FUTURE
PARKING
LOT
PARKING LOT
PROPOSED PAGE WIRE
FENCE (1.2m ht)
FUTURE WAYFINDING SIGNAGE
W
SOUTH
SASKATCHEWAN
RIVER
SOUTH
SASKATCHEWAN
RIVER
CHIEF WHITECAP PARK A-A
NN
CHIEF WHITECAP PARK B-B
W
BENCH
W
MEEWASIN / TRANS CANADA
PRIMARY TRAIL - 3.0m
SECONDARY TRAIL - 2.4m
CHIEF
WHITECAP
STATUE
EXISTING BARBED WIRE
FENCE
PROPOSED GATE
(11X17)
FENCE TO BE
EXTENDED A MIN OF
3m INTO EXISTING
VEGETATION (TYP.)
FUTURE
PARKING
LOT
FUTURE
PARKING
LOT
PEDESTRIAN GATES -
BLACK POWDER
COATED, SINGLE
SWING, INDUSTRIAL
STRENGTH, HINGE
LOCK (TYP.)
FUTURE SECONDARY TRAIL
FUTURE DOG PARK TRAIL
LOOK OUT "A"
LOOK OUT "B"
LOOK OUT 'C'
PROPOSED CHAIN LINK
FENCE 1.8m HT.
GRASSLAND
RESTORATION
2018-2023
GRASSLANDS
RESTORATION 2018-2023
1.40
3.05 TYP
6.10
X X X X X X X X X X X X X X X X X X X X X X X XX
0.15
LOCK ASSMEBLY: DAISY CHAIN LOCK
1.40
XXXXXXXXXXXXXXXXXXXXXXXXXX
0.15
2"x4" WIRE FILLED
10' FARM GATE
GATE WHEEL WITH SUSPENSION 8"
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
PAIGE WIRE FENCE SPACING
100mm-125mm TOP DIA.LINE POST
3.75 3.00
1.40
1.07 MAXIMUM SPACING OF POSTS 3.75m
0.15
100mm x 100mm x 3m
100mm-125mm TOP DIA.INTERMEDIATE BRACE
3.66mm THICK SOFTGALVANIZEDWIRE DOUBLED
ELEVATION FENCE
NOTES:1. ALL FENCE POSTS SHALL BE PRESSURE TREATED.2. ALLOWABLE TAPER FROM END TO END OF POST SHALL
NOT EXCEED 38mm IN DIAMETER. POSTS SHALL BEINSTALLED WITH THE LARGE END DOWN.
3. PAIGE WIRE FENCE WIRES TO BE SPACED AS SHOWNABOVE WITH 3.66mm THICK GALVANIZED WIRE USEDTHROUGHOUT.
4. LINE AND STAY WIRES TO BE JOINED THROUGHOUT WITHTIGHT-LOCK KNOT CONSTRUCTION (SEE DETAIL)
5. ADJACENT ROLLS OF PAIGE WIRE TO BE JOINED AT POSTLOCATIONS.
6. 40mm STAPLES TO BE SPACED 152mm INTERVALS SO THATEACH LINE WIRE IS FIRMLY ATTACHED TO THE FENCE POST.
7. NOMINAL DIMENSIONS FOR PAIGE WIRE SHOWN.8. FENCE TO BE SURVEYED IN FOR LOCATION ONLY AND
ADJUSTED ON SITE TO SUIT EXISTING CONDITIONS.9. HINGE LOCK ASSEMBLY.
DETAILTIGHT-LOCK KNOT
10 = NUMBER OF LINE WIRES47 = HEIGHT OF FENCE IN INCHES6 = STAY WIRE SPACING INCHES12.5SQ. = DIAMETER OF WIRETOP AND BOTTOM WIRES.
0.08
0.09
0.10
0.11
0.13
0.14
0.15
0.18
0.20
1.22
1.40
0.50 0.50
0.50 M
IN
.
PEDESTRIAN GATE PIPE
FRAME 50mm
GALVANIZED WIRE MESH
HINGE LOCK ASSEMBLY
45mm O.D. TYP
X X X X XX
XXXXXXXXXXXXXXXXX
Copyright ReservedThe Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to
The Copyrights to all designs and drawings are the property of
authorized by Stantec is forbidden.
Stantec without delay.
Stantec. Reproduction or use for any purpose other than that
Legend
Notes
Drawing No.
Scale
Revision
Title
Client/Project
Project No.
Sheet
of
Permit-SealChkd.Dwn. Dsgn. YY.MM.DD
File Name:
ByIssued Appd. YY.MM.DD1. ISSUED FOR DEVELOPMENT REVIEW KC CP 16.03.172. ISSUED FOR CLIENT REVIEW KC AL 18.03.27
ByRevision Appd. YY.MM.DD
ORIGINAL SHEET - ANSI D
V:\1
131\
activ
e\11
3154
640\
cad\
draw
ings
\lan
dsca
pe\p
roje
ct_d
wgs
\546
40l_d
_det
ail.d
wg
2018
/03/
28 1
1:53
AM By:
Cho
lodn
uik,
Kar
ri
MEEWASIN VALLEY AUTHORITY
CHIEF WHITECAP PARK
Saskatoon, Saskatchewan
DETAILS
113154640 AS SHOWN
L-2 3 5 0
www.stantec.comTel.
Stantec100-75 24th Street EastSaskatoon Saskatchewan S7K 0K3
306.667.2400
LAYOUT OF TRAIL, FENCE AND PLANTING IS SCHEMATIC.
EXACT LAYOUT TO BE DETERMINED ON SITE.
(11X17)
PAIGE WIRE FENCE
SCALE N.T.S.
DOUBLE FARM GATE
SCALE N.T.S.
MAN GATE
Scale N.T.S.
LOOK OUT 'A'
SCALE N.T.S.
LOOK OUT 'B'
SCALE N.T.S.
9.83
2.402.4
0
2.00 2.00
2.092.09
4.003.50
4.00
LOOK OUT 'C'
SCALE N.T.S.
9.83
2.402.4
0
2.00 2.00
2.092.09
4.003.50
4.00
9.83
2.402.4
0
2.00 2.00
2.092.09
4.003.50
4.00
Mee
was
in
0.75
0.39
1.90
1.90
0.50
NOTE:
SIGN SUPPLIED BY MEEWASIN
VALLEY AUTHORITY
REBAR
- 10M REBAR MINIMUM 100MM FROM EDGE
- #2 TIES OR WIRE SPIRAL, 500MM O.C HORIZONTAL AND VERTICAL
1.27
0.91
0.34
0.46
PILES
- .46 DIA. X 508MM DEPTH.
- EXTEND 10M REBAR INTO PILE MINIMUM 400MM
0.36
1.27
VARI
ES
0.51
0.23
0.25
Mee
was
in
EXISTINGGROUND
METAL FLANGE
HOUSING UNIT(MILD STEEL)
MEEWASIN TEXT(BOTH FACES)
2.10
1.18
1.98
4.5m SCREW PILE.
SLEEVE 200mm - WELD SLEEVE TO SCREW PILE- CONTINUOUS WELD.
SCREW PILE CAP. 75mm x 400mm x 400mmWELD CAP TO PILE - CONTINUOUS WELD.
MEEWASIN TRAIL SIGN 3/4 " STAINLESS BOLTS TOANCHOR TRAIL SIGN TO SCREW PILE CAP.
PILE DESIGN SPECIFICATIONS
1. PILE DESIGN LOADS (SERVICE OR WORKING LOADS):
- AS PER CCMC REPORT 13691-R
2. DESIGN CRITERIA
A) SOIL ASSUMED TO BE GENERALLY AS FOLLOWS:
SOIL LAYER
- STIFF CLAY OR DENSE SAND
3. PILE INSTALLER TO USE CALIBRATED EQUIPMENT AND CREATE PILE
INSTALLATION REPORT (INCLUDING TORQUE AND DEPTH READINGS)
AND SUBMIT TO ENGINEER UPON COMPLETION.
- MAXIMUM INTALL TORQUE - 27.1 KN-M (20.0 FT-KIP)
- MINIMUM INSTALL TORQUE - 5.4 KN-M(4.0 FT-KIP)
- MINIMUM EMBEDMENT - 2.1M (7.0 FT)
4. IF MINIMUM TORQUE IS NOT ACHIEVED EXTENSIONS SHOULD BE ADDED
TO ACHIEVE GREATER EMBEDMENT AND/OR GREATER TORQUE.
5. MINIMUM PILE PER EMBEDMENT HELIX MUST BE SITUATED BELOW
MAXIMUM FROST PENETRATION DEPTH.
8. WELDING TO CONFORM TO:
CSA W59 AND CSA W47.1
WELD TENSIEL STRENGTH = 490 MPA (71.1 KSI)
ALL WELDS TO BE
5
16
" (7.9) FILLET WELDS UNLESS NOTED OTHERWISE.
9. FABRICATION SHALL BE CARRIED OUT IN ACCORDANCE WITH STANDARD
PRACTICES AND ALL APPLICABLE CODES.
10. ABOVE DESIGN AND COMPONENTS SHALL CONFORM TO THE LATEST
EDITIONS OF THE BUILDING CODE, N.B.C. AND APPLICABLE BUILDING
CODES.
NOTE:
- THIS DESIGN AND INFORMATION IS SPECIAL TO ALMITA'S PRODUCT
AND IS NON-TRANSFERABLE TO OTHER MANUFACTURERS.
- MAXIMUM ALLOWABLE LOAD IS 265.0 KN (59.6 KIPS)
- SIGN SUPPLIED BY MEEWASIN VALLEY AUTHORITY
Copyright ReservedThe Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to
The Copyrights to all designs and drawings are the property of
authorized by Stantec is forbidden.
Stantec without delay.
Stantec. Reproduction or use for any purpose other than that
Legend
Notes
Drawing No.
Scale
Revision
Title
Client/Project
Project No.
Sheet
of
Permit-SealChkd.Dwn. Dsgn. YY.MM.DD
File Name:
ByIssued Appd. YY.MM.DD1. ISSUED FOR DEVELOPMENT REVIEW KC CP 16.03.172. ISSUED FOR CLIENT REVIEW KC AL 18.03.27
ByRevision Appd. YY.MM.DD
ORIGINAL SHEET - ANSI D
V:\1
131\
activ
e\11
3154
640\
cad\
draw
ings
\lan
dsca
pe\p
roje
ct_d
wgs
\546
40l_d
_det
ail.d
wg
2018
/03/
28 1
1:58
AM By:
Cho
lodn
uik,
Kar
ri
MEEWASIN VALLEY AUTHORITY
CHIEF WHITECAP PARK
Saskatoon, Saskatchewan
DETAILS
113154640 AS SHOWN
L-3 4 5 0
www.stantec.comTel.
Stantec100-75 24th Street EastSaskatoon Saskatchewan S7K 0K3
306.667.2400
LAYOUT OF TRAIL, FENCE AND PLANTING IS SCHEMATIC.
EXACT LAYOUT TO BE DETERMINED ON SITE.
(11X17)
MEEWASIN WAY FINDING SIGN (SMALL)
SCALE N.T.S.
MEEWASIN WAY FINDING SIGN (LARGE)
SCALE N.T.S.
SECTION
PLYWOOD
-20MM MARINE GRADE
ANGLE IRON
-32X32MM
THREADED ROD
-9MM DIA.
HINGE PIPE
-25MM DIA.
-PLACE OVER THREADED ROD
SEE NOTE
TRASH BIN TO BE SUPPLIED BY MEEWASIN
-GALVANIZED METAL
-500mm MAX. DIA. (18" - 20" MAX)
-750mm MAX. HEIGHT (24")
SCREWS
-60mm M10 LAG SCREWS
SLIDING PIN LOCK
Detail
PLAN VIEW
-ALL WOOD TO BE 102X102mm (ACTUAL SIZE)-ALL NUTS ON THE THREADED ROD ARE TO BE COUNTER SUNK 15mm-CHAMFER ON GATE IS TO CLEAR ANGLE IRON WHEN GATE IS OPENED-ALL DIMENSIONS IN MILLIMETERS UNLESS NOTED OTHERWISE-GALVANIZED CAN INSERTS TO BE 16.5" IN DIA. (CONFIRM DIMENSIONS WITH CofS PARKSDEPARTMENT-WASTE RECEPTACLE SUPPLIED BY MEEWASIN AUTHORITY
0.10
0.23
0.80
0.10
NOTES:
0.51TYP.0.71TYP.
1.23
0.35
2.00
0.30
0.05
-ALL TIMBER TO BE PRESSURE TREATED ACQ.-ALL HARDWARE TO BE GALVANIZED-PREFABRICATED BENCHES SUPPLIED BY MEEWASIN-MEASUREMENTS IN mm U.O.N-ENSURE POST DEPTH MINIMUM 36" BELOW GRADE.-BENCH SUPPLIED BY MEEWASIN AUTHORITY-ANCHOR THE BENCH AT LOCATION USING CABLES AND DUCKBILL ANCHORS.
NOTES:
2.00
100mm COMPACTED CRUSHER DUST
COMPACTED SUBGRADE
10 (typ)
SEAT AND BACK TIMBERS
-101 X 203mm R.C.
-ALL EXPOSED FACES TO BE PLANED
-ALL WOOD TO BE STAINED
-BOLT TO SUPPORT TIMBERS AS SHOWN
-25mm CHAMFERS AS SHOWN
M10 LAG SCREWS
-65mm LONG
-30 X 30mm METAL ANGLE
-C/W BLACK PAINT
M10 BLACK CARRAGE BOLT
-250mm LONG
STAIN FOR BENCHES
-SIKKENS TRANSLUCENT WOOD FINISH
-113 CAPE CODE GREY
0.10
0.60
0.19
0.40
SUPPORT TIMBER
-203 X 203mm R.C. P.T.
-FASTEN TO GRADE AS REQUIRED
LEG TIMBER
-203 X 203mm R.C. P.T.
FINISH GRADE
CONCRETE PAD FOR WASTE RECEPTACLE
- 800MM X 800MM X 200MM DEPTH
- 200MM GRANULAR SUBBASE
- COMPACTED SUBGRADE
- 10M REBAR
REBAR
- 10M REBAR MINIMUM 100MM FROM EDGE
- #2 TIES OR WIRE SPIRAL, 175MM O.C HORIZONTAL AND
VERTICAL
0.20
1.00
MAX
0.5
0m
0.20
Copyright ReservedThe Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to
The Copyrights to all designs and drawings are the property of
authorized by Stantec is forbidden.
Stantec without delay.
Stantec. Reproduction or use for any purpose other than that
Legend
Notes
Drawing No.
Scale
Revision
Title
Client/Project
Project No.
Sheet
of
Permit-SealChkd.Dwn. Dsgn. YY.MM.DD
File Name:
ByIssued Appd. YY.MM.DD1. ISSUED FOR DEVELOPMENT REVIEW KC CP 16.03.172. ISSUED FOR CLIENT REVIEW KC AL 18.03.27
ByRevision Appd. YY.MM.DD
ORIGINAL SHEET - ANSI D
V:\1
131\
activ
e\11
3154
640\
cad\
draw
ings
\lan
dsca
pe\p
roje
ct_d
wgs
\546
40l_d
_det
ail.d
wg
2018
/03/
28 1
:27
PM By:
Cho
lodn
uik,
Kar
ri
MEEWASIN VALLEY AUTHORITY
CHIEF WHITECAP PARK
Saskatoon, Saskatchewan
DETAILS
113154640 AS SHOWN
L-4 5 5 0
www.stantec.comTel.
Stantec100-75 24th Street EastSaskatoon Saskatchewan S7K 0K3
306.667.2400
LAYOUT OF TRAIL, FENCE AND PLANTING IS SCHEMATIC.
EXACT LAYOUT TO BE DETERMINED ON SITE.
(11X17)
MEEWASIN WASTE RECEPTACLE - RUSTIC
SCALE N.T.S.
MEEWASIN BENCH - RUSTIC
SCALE N.T.S.