Clarity Chromatography Software
Clarity 3.0 – New features
page: Date: 26.2.2010Code: P021/30A
2
More than 100 new features in version 3.0
Calibration Import/ExportChromatogramEvent table
User Interface ReportsSequence
page: Date: 26.2.2010Code: P021/30A
3
Opening the Clarity Instrument
Select your Project during
the logon
Option to select project in Login DialogAuto Lock - option to lock Instrument after
predefined period
page: Date: 26.2.2010Code: P021/30A
4
Improvements in user interface
User Options - new tab Directories to set paths for PDF reports, exports and imports
Tables - function Fill series (Sequence, Calibration, Gradient)
page: Date: 26.2.2010Code: P021/30A
5
CalibrationBracketing, Standard Addition, Normalization Improved Identification Windows Forced Compound IdentificationNew Calibration curves, Linearization of
Calibration Graph AxesCalculation by Response of Another CompoundResponse factor as Amount/Response or
Response/AmountResponse Correction Factor
page: Date: 26.2.2010Code: P021/30A
6
Calibration Options
Calibration curve check
Failure displayed in the Peak Type
column in Result Table New Calculation
types
NORMSTDADD
page: Date: 26.2.2010Code: P021/30A
7
Linearization of axes in Calibration
Select appropriate function to
linearize the values on X, Y
axes
Show linearized values in
Graph Properties
page: Date: 26.2.2010Code: P021/30A
8
New Curve Fit Types in Calibration
Select a new curve:• ln• log10• exp• pow10• Hyperbola• Half Sigmoid
page: Date: 26.2.2010Code: P021/30A
9
ChromatogramUser columns – compound name in special values Mathematical operations – invert function to
reverse polarityAdvanced peak tags File open dialog – option to change overlay modeResult table – peak type indicates more infoSupport for electronic signatures in PDF reports
page: Date: 26.2.2010Code: P021/30A
10
Enhanced Peak Type info
Peak Type in Result Table indicates used calibration options
Ordnr/Ref/ISTD/RISTD/GRP peak typeError value could not be calculatedError (Curve Check) calibration curve does not met preset criteria<LOD and<LOQ value lower then set limits(Forced) identification forced by integration table(by name) another compound calibration data used(CF) correction factor in calibration applied
page: Date: 26.2.2010Code: P021/30A
11
Overlay mode
Change to Overlay mode in
Open Chromatogram
dialog
page: Date: 26.2.2010Code: P021/30A
12
Electronic signatures in PDF reports
page: Date: 26.2.2010Code: P021/30A
13
Force Peak Identification
Force Peak Identificati
onSelect Peak
to Force
Select new Peak
Identification
Name peaks without calibration file
Override identification by calibration
page: Date: 26.2.2010Code: P021/30A
14
Relative Retention Times
Force Peak Identificati
on
Calculated RRT
Setup User Column using
the Special Values,
Compound option
page: Date: 26.2.2010Code: P021/30A
15
Customizable order of Report Sections
Right click the tab and adjust its
position
page: Date: 26.2.2010Code: P021/30A
16
Export of graphsExport of graphs from PDA viewExport Calibration curve as picture
[g/kg]Amount0,0 0,5 1,0 1,5 2,0 2,5 3,0
[mV.s]
Resp
onse
0
50
100
150
page: Date: 26.2.2010Code: P021/30A
17
Export of data in Excel (.xls) format
page: Date: 26.2.2010Code: P021/30A
18
Import Chromatogram Data
Store your preferences
for future use(user specific)
Import of multiple signal
chromatogram data
aranged in columns
Preview the imported data
file
Preview the imported data
file
Apply same settings to
multiple files opened
simultaneously
page: Date: 26.2.2010Code: P021/30A
19
Event tableEvents could be performed outside runNew input conditionsNew output actionsResizable dialog and columns width
New set of event for
running/idle state of
Instrument
New set of commands in
Output
page: Date: 26.2.2010Code: P021/30A
20
Valve control Set custom
position for Valve at Close Instrument
Input/Output names instead of
numbers
Set custom position for Valve
at Close Instrument
page: Date: 26.2.2010Code: P021/30A
21
SequenceBypass to perform run without injection for
startup and shutdown methods
New file name variables
%P – Project%s – Sequence%J – Method
New columns:• Include in SST – perform SST
test when injection is finished
• Stored Calib. – chromatogram will be opened with stored calibration
• Close All – close all currently opened chromatograms in overlay to prepare for next summary report
page: Date: 26.2.2010Code: P021/30A
22
Bracketing and Standard Addition
Calibration and Sequence Usage
Clone calibration at each Sequence start
Standard AdditionBracketing
This calibration will be used with Calibration used as
specified by user
Copy of the Example Calibration will be created according to Sequence options,
Calibration and Sequence Usage
page: Date: 26.2.2010Code: P021/30A
23
Extension and Control ModulesPDA – option Add All Identified Peaks to
Spectrum library FC GP – new option Collect all Flow rate units options extended to L/min,
mL/min, µL/min
page: Date: 26.2.2010Code: P021/30A
24
Control Modules in development
Agilent 7890 GC Agilent 1200 HPLC DAD (G1315D)Sedere ELSD detector 80LT and
85LTPG Instruments LC-200 HPLC
page: Date: 26.2.2010Code: P021/30A
25
For more information please visit our website:
What‘s new ( menu: Products – Clarity – Next steps – What is new)
Preliminary Demo version ( menu: Downloads – Preliminary versions)
Preliminary version ( menu: Downloads – Preliminary versions)