+ All Categories
Home > Documents > Clarity GPC module

Clarity GPC module

Date post: 10-Jan-2016
Category:
Upload: raoul
View: 33 times
Download: 1 times
Share this document with a friend
Description:
Clarity GPC module. GPC Extension. Optional extension for SEC/GPC data evaluation. GPC mode. GPC Instrument is configured in System Configuration window GPC or Standard mode can be selected on GPC Instrument Chromatograms can be evaluated alternatively in both modes. - PowerPoint PPT Presentation
15
page: Clarity GPC module Date: 3.11.2009 Code: P002/28A 1
Transcript
Page 1: Clarity GPC module

page:

Clarity GPC module

Date: 3.11.2009Code: P002/28A

1

Page 2: Clarity GPC module

page:

Optional extension for SEC/GPC data evaluation

Date: 3.11.2009Code: P002/28A

2

GPC Extension

Page 3: Clarity GPC module

page:

GPC mode

Date: 3.11.2009Code: P002/28A

3

GPCInstrument Type

GPC / Standard mode switching

GPC mode method tabs

GPC Instrument is configured in System Configuration window

GPC or Standard mode can be selected on GPC Instrument

Chromatograms can be evaluated alternatively in both modes

Page 4: Clarity GPC module

page:

GPC Calibration Molecular weight as a function of

elution volume

Narrow standards

Flow rate correction

Universal calibration

Broad calibrationmultiple linear (Hamielec) fitmultiple integral standardbroad on narrow

Date: 3.11.2009Code: P002/28A

4

Page 5: Clarity GPC module

page:

Narrow standard

Date: 3.11.2009Code: P002/28A

5

Page 6: Clarity GPC module

page:

Flow rate correction

Date: 3.11.2009Code: P002/28A

6

Set Flow rate correction

Set FM peak

Page 7: Clarity GPC module

page:

Flow Rate Correction

Date: 3.11.2009Code: P002/28A

7

Page 8: Clarity GPC module

page:

Universal

Date: 3.11.2009Code: P002/28A

8

Universal calibration On

Mark-Houwink parameters

Page 9: Clarity GPC module

page:

Broad standard

Date: 3.11.2009Code: P002/28A

9

Page 10: Clarity GPC module

page:

Broad on Narrow

Date: 3.11.2009Code: P002/28A

10

Calculated parameters

Page 11: Clarity GPC module

page:

Results table

Date: 3.11.2009Code: P002/28A

11

Page 12: Clarity GPC module

page:

Summary Table

Date: 3.11.2009Code: P002/28A

12

Page 13: Clarity GPC module

page:

Slice Table

Date: 3.11.2009Code: P002/28A

13

Page 14: Clarity GPC module

page:

MW distributions

Date: 3.11.2009Code: P002/28A

14

Page 15: Clarity GPC module

page:

MW Ranges

Date: 3.11.2009Code: P002/28A

15

MW averages for selected percentages

Percentages for selected MW ranges


Recommended