46
Ξ Nortek Air Solutions, LLC CLEANPAK | 19855 SW 124th Ave, Tualatin, OR 97062 | 503.639.0113 | www.huntair.com Products may be protected under one or more of the patents listed under www.nortekair.com/patents CLEAN-TRAK BOTTOM-LOAD FLUSH CEILING SYSTEM CLEANPAK offers an extension to the patented Clean-Trak flush ceiling system with its Bottom-Load Flush ceiling. This extrusion is suited for applications where the space above the ceiling grid is limited and where the application calls for the filters to contain gel rather than the ceiling grid. It enables you to load filters, fan filter units, or blank pans straight up without tipping or rotating them through the grid opening. The extrusion features a downward facing knife-edge to which the gel in the filter or blank pan will seal. Also available in formed stainless steel. KEY FEATURES ā Integral knife-edge extrusion. Optional formed stainless steel. ā Welded module grid with welded knife-edges miters. Optional stick-built grid with field caulked miters. ā Integral lighting--T8, T5, or LED. ā Continuous slot extrusion for the retaining clips allows for superior load capacity. ā ó turn filter retaining clips that do not generate particles (we do not use a screw receiver extrusion since it generates particles). ā Closure strip for the slot to eliminate particle cavities. ā A true flush concealed sprinkler head can be used in the grid extrusion. ā Filters that are pre-gelled at the filter manufacturer¶s facility. ā Option to be walkable on the filters, FFUs, or blank pans. ā Optional Equalizer can be used to balance the system with a center adjustment port in the filter. ā Optional plenum can. ā Of course, this system includes all the features and options of the patented Clean-Trak ceiling system such as the flush ceiling, integrated lighting, built-in fire protection, Clean-Screens , welded modular grids or stickbuilt grids, modular plenums, special finishes for chemical resistance, and GelLink seal at module joints. CONDENSED SPECIFICATION optional items noted in [ ] The grid [plenum] system shall be Clean-Trak Bottom-Load Flush as manufactured by CLEANPAK International. The grid will have a downward facing knife-edge that will accept pre-gelled filters. [Welded modules shall have welded knife-edge miters.] Filters, blank pans, and FFUs shall be capable of being loaded from the bottom without tipping or rotating of the filters into the grid opening. The grid extrusion shall have integrated flush lighting within the grid channel that is capable of 100% filter coverage of the entire ceiling. The extrusion shall have a continuous slot to seat a nut to which the filter retaining clip shall attach. A screw receiver slot extrusion shall not be used. The grid extrusion shall be capable of accepting a true flush sprinkler head within the width of the extrusion. [The grid shall have a GelLink seal that flows gel between module joints.] [The grid shall have Clean-Screens at the grid face that have perimeter slots to jet air underneath the grid member and wash out the area of particles.] CLEANPAK a Nortek Air Solutions Brand _
Transcript
Page 1: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

© Nortek Air Solutions, LLC CLEANPAK | 19855 SW 124th Ave, Tualatin, OR 97062 | 503.639.0113 | www.huntair.comProducts may be protected under one or more of the patents listed under www.nortekair.com/patents

CLEAN-TRAK BOTTOM-LOAD

FLUSH CEILING SYSTEM

CLEANPAK offers an extension to the patented Clean-Trak® flush ceiling system with its Bottom-Load

Flush ceiling. This extrusion is suited for applications where the space above the ceiling grid is limited

and where the application calls for the filters to contain gel rather than the ceiling grid. It enables you to

load filters, fan filter units, or blank pans straight up without tipping or rotating them through the grid

opening. The extrusion features a downward facing knife-edge to which the gel in the filter or

blank pan will seal. Also available in formed stainless steel.

KEY FEATURES

· Integral knife-edge extrusion. Optional formed stainless steel.

· Welded module grid with welded knife-edges miters. Optional stick-built grid with field caulked miters.

· Integral lighting--T8, T5, or LED.

· Continuous slot extrusion for the retaining clips allows for superior load capacity.

· ¼ turn filter retaining clips that do not generate particles (we do not use a screw receiver extrusion

since it generates particles).

· Closure strip for the slot to eliminate particle cavities.

· A true flush concealed sprinkler head can be used in the grid extrusion.

· Filters that are pre-gelled at the filter manufacturer’s facility.

· Option to be walkable on the filters, FFUs, or blank pans.

· Optional Equalizer can be used to balance the system with a center adjustment port in the filter.

· Optional plenum can.

· Of course, this system includes all the features and options of the patented Clean-Trak ceiling system such

as the flush ceiling, integrated lighting, built-in fire protection, Clean-Screens® , welded modular grids or

stickbuilt grids, modular plenums, special finishes for chemical resistance, and GelLink™ seal at module joints.

CONDENSED SPECIFICATION optional items noted in [ ]

The grid [plenum] system shall be Clean-Trak Bottom-Load Flush as manufactured by CLEANPAK International. The grid will have

a downward facing knife-edge that will accept pre-gelled filters. [Welded modules shall have welded knife-edge miters.] Filters,

blank pans, and FFUs shall be capable of being loaded from the bottom without tipping or rotating of the filters into the grid opening.

The grid extrusion shall have integrated flush lighting within the grid channel that is capable of 100% filter coverage of the entire

ceiling. The extrusion shall have a continuous slot to seat a nut to which the filter retaining clip shall attach. A screw receiver slot

extrusion shall not be used. The grid extrusion shall be capable of accepting a true flush sprinkler head within the width of the

extrusion. [The grid shall have a GelLink seal that flows gel between module joints.] [The grid shall have Clean-Screens at the grid

face that have perimeter slots to jet air underneath the grid member and wash out the area of particles.]

CLEANPAKa Nortek Air Solutions Brand

Page 2: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 2 OF 46

B

TITLE:

2.6 BOTTOM LOAD

MASTER TOP ISO

ZC

2.6BottomLoad.idw

FILE NAME:

Page 3: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

Bottom Load

SCALE 3/32

A AB B

CC

D D

E EF FG GH H

J JK KL L

M M

N N

P P

R R

T T

UU

VV

W W

YY

Z Z

AA AA

AB AB

AC AC

AD AD

AE AE

AF AF

AG AG

AH AH

AJ AJ AK AK

AL

AL

AM

AM

AN AN

AP AP

AR AR

AT AT

AU AU

AV AV

AW AW

BB

BB

BD BD

BF BF

BG BG

BHBH

BJ BJ

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 3 OF 46

E

TITLE:

2.6 BOTTOM LOAD

MASTER PLAN VIEW

Jon H

10/23/12

3/32

2.6BottomLoad.idw

FILE NAME:

Page 4: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

PAINTWELDUOBQTYDESCRIPTION ITEMLEVEL

EXTR 2.6 BOT INT TB240-10-2011|

EXTR 2.6 BOT INT240-10-2042|

EXTR 2.6 BOT EXT240-10-2023|

EXTR 2.6 BOT EXT PLEN RVT240-10-2004|

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 4 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

EXTRUSION PROFILES

Jon H

07/01/13

3/8

2.6BottomLoad.idw

FILE NAME:

4.540

2.600

2.625

4.540

2.625

2.600

2.625

1.300

8.000

2.625

8.460

1.300

5.050

7.610

2

1

3 4

Page 5: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION A-A

SCALE 1 / 2

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 5 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

SPRINKLER CONCEALED HARD PIPED

TYPE "B" COUPLING

Jon H

10/23/12

1/2

2.6BottomLoad.idw

FILE NAME:

1" SCH 40 PIPE

(BY OTHERS)

TYPE "B" COUPLING

THREADED 1" FEMALE

EIGHT LUG

LOCKING NUT

MIRAGE CONCEALED

SPRINKLER

Page 6: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION B-B

SCALE 1 / 2

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 6 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

SPRINKLER PENDANT HARD PIPED

TYPE "M" THREADED COUPLING

Jon H

10/23/12

1/2

2.6BottomLoad.idw

FILE NAME:

1" SCH 40 PIPE

(BY OTHERS)

EIGHT LUG

LOCKING NUT

SPRINKLER HEAD

(INSTALLED BY OTHERS)

TYPE "M" COUPLING

THREADED 1" FEMALE

Page 7: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION C-C

SCALE 1 / 2

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 7 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

SPRINKLER FLEXIBLE HOSE

Jon H

10/23/12

1/2

2.6BottomLoad.idw

FILE NAME:

SPRINKLER HOSE

SPRINKLER HEAD

(INSTALLED BY OTHERS)

SPRINKLER PORT

Page 8: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION D-D

SCALE 1 / 2

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 8 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

PORT

Jon H

10/23/12

1/2

2.6BottomLoad.idw

FILE NAME:

PORT

Page 9: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION E-E

SCALE 5/16

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 9 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

FILTER BOTTOM LOAD PLENUM STYLE

Jon H

10/23/12

5/16

2.6BottomLoad.idw

FILE NAME:

NOMINAL GRID CENTERLINES - 3.875"

Page 10: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION F-F

SCALE 5/16 CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 10 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

FILTER BOTTOM LOAD PLENUM STYLE

WITH TOP FLANGE

Jon H

10/23/12

5/16

2.6BottomLoad.idw

FILE NAME:

FILTER SIZED AT NOMINAL GRID CENTERLINES - 3.875"

SIZE COMPONENTS AT GRID NOMINAL CENTERLINES - 5.625"

TO FIT INTO THIS TOP FILTER LEDGE

5.341

DISTANCE INSIDE FILTER LEG IS GRID NOM CENTERLINES - 5.441"

Page 11: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION G-G

SCALE 5/16

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 11 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

FILTER BOTTOM LOAD TERMINAL

DUCTED FILTER STYLE

Jon H

10/23/12

5/16

2.6BottomLoad.idw

FILE NAME:

FILTER SIZED AT NOMINAL GRID CENTERLINES - 3.875"

7.724

9.724

Page 12: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION H-H

SCALE 5/16

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 12 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

BOTTOM LOAD BLANK PAN GEL

Jon H

10/23/12

5/16

2.6BottomLoad.idw

FILE NAME:

NOMINAL GRID CENTERLINES - 3.875"

.750

Page 13: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION J-J

SCALE 5/16

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 13 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

EQUALIZER ON

BOTTOM LOAD PLENUM FILTER

Jon H

10/23/12

5/16

2.6BottomLoad.idw

FILE NAME:

EQUALIZER SIZED AT

NOMINAL GRID CENTERLINES - 5.25"

FILTER SIZED AT NOMINAL GRID CENTERLINES - 3.875"

Page 14: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION Y-Y

SCALE 5/16

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 14 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

EQUALIZER REMOVEABLE ON

BOTTOM LOAD PLENUM STYLE

FILTER WITH TOP FLANGE

Jon H

04/12/13

5/16

2.6BottomLoad.idw

FILE NAME:

EQUALIZER SIZED AT

NOMINAL GRID CENTERLINES - 5.625"

FILTER SIZED AT NOMINAL GRID CENTERLINES - 3.875"

Page 15: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION K-K

SCALE 5/16

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 15 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

EQUALIZER IN GRID

NON-FILTERED APPLICATION

Jon H

10/23/12

5/16

2.6BottomLoad.idw

FILE NAME:

NOMINAL GRID CENTERLINES - 3.875"

3.290

Page 16: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION L-L

SCALE 5/16

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 16 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

EQUALIZER ON GRID

Jon H

10/23/12

5/16

2.6BottomLoad.idw

FILE NAME:

NOMINAL GRID CENTERLINES - 3.50"

7.657

8.620

Page 17: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION BH-BH

SCALE 5/16

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 17 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

CLEAN SCREEN 40%

Jon H

06/04/14

5/16

2.6BottomLoad.idw

FILE NAME:

NOMINAL GRID CENTERLINES - 2.50"

40% OPEN STAGGERED

PERF PATTERN

Page 18: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION Z-Z

SCALE 1/4

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 18 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

FFU-AC1-EB ON BOTTOM LOAD

PLENUM STYLE FILTER

WITH TOP FLANGE

ZC

04/12/13

1/4

2.6BottomLoad.idw

FILE NAME:

FFU SIZED AT

NOMINAL GRID CENTERLINES - 5.625"

15.591

14.591

5.341

10.250

FILTER SIZED AT NOMINAL GRID CENTERLINES - 3.875"

CORNER PLATE

TYP. (4) LOCATIONS

Page 19: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION AW-AW

SCALE 5/16

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 19 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

FFU-DC-EB ON BOTTOM LOAD

PLENUM STYLE FILTER

WITH TOP FLANGE

JLH

02/12/14

5/16

2.6BottomLoad.idw

FILE NAME:

FILTER SIZED AT NOMINAL GRID CENTERLINES - 3.875"

15.404

16.347

10.063

.943

FFU SIZED AT

NOMINAL GRID CENTERLINES - 5.625"

5.341

CORNER PLATE

TYP. (4) LOCATIONS

INCOMING POWER LOCATION.

6" WIRE LEADS.

ELECTRICAL CONNECTION AND FLEX BY OTHERS.

LOCAL SPEED POT ADJUSTMENT

(IF APPLICABLE)

COMMUNICATION HOOKUP

(IF APPLICABLE)

Page 20: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION BG-BG

SCALE 1/2

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 20 OF 46

A

TITLE:

2.6 BOTTOM LOAD

FLUSH LIGHT LED

Jon H

04/23/14

1/2

2.6BottomLoad.idw

FILE NAME:

Page 21: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION M-M

SCALE 2/3

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 21 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

FLUSH LIGHT T5

Jon H

10/24/12

1/2

2.6BottomLoad.idw

FILE NAME:

Page 22: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION N-N

SCALE 2/3

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 22 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

FLUSH LIGHT T8

Jon H

10/24/12

1/2

2.6BottomLoad.idw

FILE NAME:

Page 23: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION T-T

SCALE 1 / 2

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 23 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

GEL-LINK MODULE TO MODULE JOINT

MODULE SEAM LIGHTING (IF APPLICABLE)

Jon H

10/26/12

1/2

2.6BottomLoad.idw

FILE NAME:

5.05

TYP.

TACK WELD

.080 ALUMINUM

3/4 x 5/8 ANGLE

TO CREATE

TROUGH

5/16-18 WHIZ NUT

BOLT HOLES ARE TYPICALLY

SPACED 6.0" FROM EACH END

OF PLENUM AND 24.0" O.C.

EXTERIOR GRID PROFILE

5/16" WASHER

5/16-18 x 3/4" BOLT

EXTERIOR PUNCHED

FOR GEL SHARE

2.600

FIELD CAULKING

FIELD INSTALLED

LIGHT FIXTURE (IF APPLICABLE)

Page 24: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION AG-AG

SCALE 1 / 2

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 24 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

MODULE TO MODULE JOINT

Jon H

05/19/13

1/2

2.6BottomLoad.idw

FILE NAME:

FIELD INSTALLED

LIGHT FIXTURE

FIELD CAULKING

5/16-18 WHIZ NUT

BOLT HOLES IN MODULES

ARE TYPICALLY

SPACED 6.0" FROM EACH END

OF PLENUM AND 24.0" O.C.

EXTERIOR GRID PROFILE

5/16" WASHER

5/16-18 x 3/4" BOLT

Page 25: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION P-P

SCALE 1 / 2

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 25 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

PERIMETER GRID

Jon H

10/24/12

1/2

2.6BottomLoad.idw

FILE NAME:

5/16-18 WHIZ NUT

BOLT HOLES IN MODULES

ARE TYPICALLY

SPACED 6.0" FROM EACH END

OF PLENUM AND 24" O.C.

PERIMETER GRID PROFILE

5/16" WASHER

5/16-18 x 0.75" BOLT

5.050 TYP.

FACE PLATE W/ GRID CLIP

FIELD CAULKING

NOTES:

FIELD CUTTING OF PERIMETER GRID INCLUDING CORNER MITERS ARE

TO BE DONE IN THE FIELD. SOME BOLT HOLES IN PERIMETER GRID

PIECES WILL NEED TO BE CUSTOM DRILLED IN THE FIELD.

Page 26: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION V-V

SCALE 1 / 2

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 26 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

PERIMETER GRID

WITH CLOSURE PLATE TO WALL

Jon H

10/29/12

1/2

2.6BottomLoad.idw

FILE NAME:

PERIMETER GRID

PROFILE

5/16" WASHER

5/16-18 x .75"

BOLT

BOLT HOLES IN MODULES ARE

TYPICALLY SPACED

6.0" FROM EACH END

OF PLENUM AND

24.0" O.C.

5/16-18 WHIZ NUT

FACE PLATE W/ GRID CLIP

FIELD GASKET OR

CAULKING BY OTHERS

CLOSURE PLATE TRIMED

TO WIDTH IN FIELD

FIELD CAULKING

NOTES:

FIELD CUTTING OF PERIMETER GRID INCLUDING CORNER MITERS ARE

TO BE DONE IN THE FIELD. BOLT HOLES IN PERIMETER GRID PIECES

WILL NEED TO BE CUSTOM DRILLED IN THE FIELD.

Page 27: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION R-R

SCALE 1 / 2

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 27 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

PERIMETER GRID

WITH CLOSURE PLATE AND

GEL SEALED FUNCTIONAL WALL CLOSURE

Jon H

10/25/12

1/2

2.6BottomLoad.idw

FILE NAME:

PERIMETER GRID PROFILE

5/16" WASHER

5/16-18 x .75" BOLT

BOLT HOLES IN

MODULES ARE

TYPICALLY SPACED

6.0" FROM EACH

END OF PLENUM

AND 24.0" O.C.

5/16-18 WHIZ NUT

.080 ALUMINUM

3/4 x 5/8 ANGLE

TO CREATE

TROUGH

TACK WELD

CLOSURE PLATE TRIMMED

TO WIDTH IN FIELD

FACE PLATE WITH

GRID CLIP

FIELD CAULKING

FIELD CAULK

BY OTHERS

ATTACHMENT TO

WALL BY OTHERS

EXTERIOR PUNCHED

FOR GEL SHARE

FIELD GASKET OR

CAULKING BY OTHERS

NOTES:

FIELD CUTTING OF PERIMETER GRID INCLUDING CORNER

MITERS ARE TO BE DONE IN THE FIELD. SOME BOLT HOLES

IN PERIMETER GRID PIECES WILL NEED TO BE CUSTOM

DRILLED IN THE FIELD.

Page 28: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION U-U

SCALE 1 / 2

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 28 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

PERIMETER GRID WITH ANGLE LEDGE

Jon H

10/29/12

1/2

2.6BottomLoad.idw

FILE NAME:

5/16-18 WHIZ NUT

BOLT HOLES IN MODULES

ARE TYPICALLY

SPACED 6.0" FROM EACH END

OF PLENUM AND 24.0" O.C.

PERIMETER GRID

PROFILE

5/16" WASHER

5/16-18 x 3/4" BOLT

1"x1" ANGLE WELDED

TO SHIP LOOSE

PERIMETER GRID

FIELD CAULKING

NOTES:

FIELD CUTTING OF PERIMETER GRID INCLUDING CORNER

MITERS ARE TO BE DONE IN THE FIELD. SOME BOLT HOLES

IN PERIMETER GRID PIECES WILL NEED TO BE CUSTOM

DRILLED IN THE FIELD.

Page 29: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION W-W

SCALE 1 / 2

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 29 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

PERIMETER GRID INTERFACE

TO WALL COVED

Jon H

10/30/12

1/2

2.6BottomLoad.idw

FILE NAME:

SHEET METAL

Z PIECE

BY OTHERS

WALL AND COVING

BY OTHERS

FIELD CAULKING

NOTES:

FIELD CUTTING OF PERIMETER GRID INCLUDING CORNER

MITERS ARE TO BE DONE IN THE FIELD. BOLT HOLES IN

PERIMETER GRID PIECES WILL NEED TO BE CUSTOM

DRILLED IN THE FIELD.

Page 30: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 30 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

BOTTOM LOAD CLIP RETAINER

LAYOUT PLAN VIEW

Jon H

10/29/12

1/8

2.6BottomLoad.idw

FILE NAME:

Y

X

NOTES:

1. INSTALL CLIP RETAINER ASSEMBLIES 8.30" IN FROM

CENTERLINE OF GRID STICK ON THE LONG SIDES OF

GRID OPENINGS.

2. X AND Y ARE NOMINAL CENTERLINE DIMENSIONS OF GRID.

3. FOR FFUs OR WALKABLE PANS, ADD 4 CORNER PLATES

PER OPENING.

Page 31: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION AA-AA

SCALE 1/4

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 31 OF 46

A

TITLE:

2.6 BOTTOM LOAD PLENUM

PERIMETER GRID

Jon H

04/15/13

1/2

2.6BottomLoad.idw

FILE NAME:

5/16-18 WHIZ NUT

PERIMETER GRID

PROFILE

5/16" WASHER

5/16-18 x 0.75"

BOLT

FACE PLATE W/

GRID CLIP

5.050

FIELD CAULKING

NOTES:

FIELD CUTTING OF PERIMETER GRID INCLUDING CORNER MITERS ARE

TO BE DONE IN THE FIELD. BOLT HOLES IN PERIMETER GRID PIECES

WILL NEED TO BE CUSTOM DRILLED IN THE FIELD.

Page 32: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION AB-AB

SCALE 1 / 4

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 32 OF 46

A

TITLE:

2.6 BOTTOM LOAD PLENUM

PERIMETER GRID WITH ANGLE LEDGE

Jon H

04/15/13

1/2

2.6BottomLoad.idw

FILE NAME:

1"x1" ANGLE WELDED

TO SHIP LOOSE

PERIMETER GRID

PERIMETER GRID

PROFILE

5/16" WASHER

5/16-18 x 3/4" BOLT

BOLT HOLES IN MODULES ARE

TYPICALLY SPACED

6.0" FROM EACH END

OF PLENUM AND

24.0" O.C.

5/16-18 WHIZ NUT

FIELD CAULKING

FACE PLATE W/ GRID CLIP

NOTES:

FIELD CUTTING OF PERIMETER GRID INCLUDING CORNER

MITERS ARE TO BE DONE IN THE FIELD. SOME BOLT HOLES

IN PERIMETER GRID PIECES WILL NEED TO BE CUSTOM

DRILLED IN THE FIELD.

Page 33: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION AC-AC

SCALE 1/4

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 33 OF 46

A

TITLE:

2.6 BOTTOM LOAD PLENUM

PERIMETER GRID WITH

CLOSURE PLATE TO WALL

Jon H

04/16/13

1/4

2.6BottomLoad.idw

FILE NAME:

BOLT HOLES IN

MODULES ARE

TYPICALLY SPACED

6.0" FROM EACH END

OF PLENUM AND

24.0" O.C.

5/16-18 WHIZ NUT

5/16-18 x .75"

BOLT

PERIMETER GRID

PROFILE

5/16" WASHER

FIELD GASKET OR

CAULKING BY OTHERS

CLOSURE PLATE TRIMMED

TO WIDTH IN FIELD

FACE PLATE W/

GRID CLIP

FIELD CAULKING

NOTES:

FIELD CUTTING OF PERIMETER GRID INCLUDING CORNER

MITERS ARE TO BE DONE IN THE FIELD. SOME BOLT HOLES

IN PERIMETER GRID PIECES WILL NEED TO BE CUSTOM

DRILLED IN THE FIELD.

Page 34: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION AD-AD

SCALE 1 / 4

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 34 OF 46

A

TITLE:

2.6 BOTTOM LOAD PLENUM

PERIMETER GRID WITH

CLOSURE PLATE TO WALL AND GEL

SEALED FUNCTIONAL WALL CLOSURE

Jon H

04/16/13

1/4

2.6BottomLoad.idw

FILE NAME:

FIELD GASKET OR

CAULKING BY OTHERS

FIELD CAULKING

FACE PLATE WITH

GRID CLIP

TACK WELD

.080 ALUMINUM

3/4 x 5/8 ANGLE

TO CREATE

TROUGH

5/16-18 WHIZ NUT

5/16" WASHER

5/16-18 x .75" BOLT

ATTACHMENT TO

WALL BY OTHERS

CLOSURE PLATE TRIMMED

TO WIDTH IN FIELD

FIELD CAULK

BY OTHERS

NOTES:

FIELD CUTTING OF PERIMETER GRID INCLUDING CORNER

MITERS ARE TO BE DONE IN THE FIELD. SOME BOLT HOLES

IN PERIMETER GRID PIECES WILL NEED TO BE CUSTOM

DRILLED IN THE FIELD.

Page 35: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION AE-AE

SCALE 1 / 4

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 35 OF 46

A

TITLE:

2.6 BOTTOM LOAD PLENUM

PERIMETER GRID INTERFACE

TO WALL COVED

Jon H

04/29/13

1/4

2.6BottomLoad.idw

FILE NAME:

SHEET METAL

Z PIECE

BY OTHERS

5/16-18 x .75"

BOLT

5/16" WASHER

PERIMETER GRID

PROFILE

5/16-18 WHIZ NUT

FIELD CAULKING

WALL AND COVING

BY OTHERS

NOTES:

FIELD CUTTING OF PERIMETER GRID INCLUDING CORNER

MITERS ARE TO BE DONE IN THE FIELD. SOME BOLT HOLES

IN PERIMETER GRID PIECES WILL NEED TO BE CUSTOM

DRILLED IN THE FIELD.

Page 36: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION AF-AF

SCALE 1 / 4

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 36 OF 46

A

TITLE:

2.6 BOTTOM LOAD PLENUM

MODULE TO MODULE JOINT

MODULE SEAM LIGHTING (IF APPLICABLE)

Jon H

05/03/13

1/4

2.6BottomLoad.idw

FILE NAME:

FIELD CAULKING

FIELD INSTALLED

LIGHT FIXTURE

5/16-18 WHIZ NUT

5/16" WASHER

5/16-18 x .75"

BOLT

Page 37: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION AH-AH

SCALE 1 / 4

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 37 OF 46

A

TITLE:

2.6 BOTTOM LOAD PLENUM

GEL-LINK MODULE TO MODULE JOINT

MODULE SEAM LIGHTING (IF APPLICABLE)

2.6BottomLoad.idw

FILE NAME:

5/16" WASHER

5/16-18 x .75"

BOLT

EXTERIOR GRID

PROFILE

5/16-18 WHIZ NUT

FIELD CAULKING

FIELD INSTALLED

LIGHT FIXTURE

IF APPLICABLE

GEL POURED IN FIELD

.080 ALUMINUM

3/4 x 5/8 ANGLE WELDED

FROM FACTORY

TO CREATE TROUGH

Page 38: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

AT PERIMETER GRID SECTION AJ-AJ

SCALE 3/8

AT INTERIOR GRID SECTION AK-AK

SCALE 3/8

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 38 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

WITH WALL INTERFACE

Jon H

05/16/13

3/8

2.6BottomLoad.idw

FILE NAME:

FIELD CAULKING

WALL TO HEAD

TRACK BY OTHERS

WALL TO HEAD

TRACK BY OTHERS

HEAD TRACK BY OTHERS

HEAD TRACK BY OTHERS

Page 39: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION AL-AL

SCALE 3/16

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 39 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

BOLTING DETAIL

WELDED PLENUM TO WELDED PLENUM

Jon H

05/16/13

3/16

2.6BottomLoad.idw

FILE NAME:

ATR BOLTED TO HOLE IN TOP OF PLENUM

(HANGING ATR AND HARDWARE BY OTHERS)

1. BOLT TOGETHER LOOSELY WHEN SUSPENDING MODULES

5. TIGHTEN SUSPENSION HARDWARE

4. BOLTS ALONG TOP OF PLENUM

3. BOLTS AT PLENUM

CORNERS

2. BOLTS AT PLENUM GRID

5/8"x1-1/4 A325

BOLT, TYP.

5/8" F436 FLAT

WASHER, TYP.

5/8" F436 FLAT

WASHER, TYP.

5/8" A194 GR2H

NUT, TYP.

5/16x3/4 GR5 BOLT

5/16" FLAT WASHER

5/16" WHIZNUT

NOTE:

NUMBERS INDICATE SEQUENCE ORDER

FOR MODULE INSTALLATION ASSEMBLY.

1

.

5

0

T

Y

P

.

1

.

5

0T

Y

P

.

Page 40: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION AM-AM

SCALE 3/32

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 40 OF 46

A

TITLE:

2.6 BOTTOM LOAD GRID

TYPICAL PLENUM SPRINKLER PIPING

Jon H

05/20/13

3/32

2.6BottomLoad.idw

FILE NAME:

SPRINKLER HEAD INSTALLED IN FIELD BY OTHERS

WELDED SPRINKLER COUPLER

ROOF PANEL

Page 41: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION AT-AT

TYPE 3B HANGER GRID TO GRID

LOAD CAPACITY: 3.75 Kips

SECTION AU-AU

TYPE 2B HANGER MIDSPAN

LOAD CAPACITY: 3.75 Kips

SECTION AV-AV

TYPE 4X HANGER CORNER

LOAD CAPACITY: 2.75 Kips

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 41 OF 46

B

TITLE:

TYPICAL HANGERS 1/2" ATR

Jon H

07/12/13

1/4

2.6BottomLoad.idw

FILE NAME:

Page 42: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION AN-AN

TYPE 3C HANGER GRID TO GRID

LOAD CAPACITY: 6.97 Kips

SECTION AP-AP

TYPE 3C HANGER MIDSPAN

LOAD CAPACITY: 6.97 Kips

SECTION AR-AR

TYPE 4Z HANGER CORNER

LOAD CAPACITY: 2.75 Kips

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 42 OF 46

B

TITLE:

TYPICAL HANGERS 5/8" ATR

Jon H

07/12/13

2.6BottomLoad.idw

FILE NAME:

Page 43: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

DETAIL BA

SECTION BB-BB

SCALE 3/32

BA

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 43 OF 46

A

TITLE:

2.6 BOTTOM LOAD PLENUM

TUBE HANDRAIL CONNECTION

Jon H

04/22/14

2.6BottomLoad.idw

FILE NAME:

9.000

2.000

HANDRAIL

Page 44: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

DETAIL BC

SCALE 3/32

SECTION BD-BD

SCALE 3/32

BC

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 44 OF 46

A

TITLE:

2.6 BOTTOM LOAD PLENUM

STRUT HANDRAIL CONNECTION

Jon H

04/22/14

3/32

2.6BottomLoad.idw

FILE NAME:

9.000

HANDRAIL

Page 45: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

DETAIL BE

SCALE 1/16

SECTION BF-BF

SCALE 1/4

BE

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 45 OF 46

A

TITLE:

2.6 BOTTOM LOAD PLENUM

GRATING LEDGE ANGLE

Jon H

04/22/14

N/A

2.6BottomLoad.idw

FILE NAME:

CLIENT TO SPECIFY

DISTANCE FROM TOP

OF LEDGE ANGLE TO

TOP OF PLENUM

GRATING

BY OTHERS

SUPPORT BY OTHERS

HARDWARE AND

HOLES BY OTHERS

Page 46: CLEANPAK CLEAN-TRAK BOTTOM-LOAD FLUSH · PDF fileA true flush concealed sprinkler head can be used in the grid extrusion. ... 1 240-10-201 EXTR 2.6 BOT INT TB | 2 240-10-204 EXTR 2.6

SECTION BJ-BJ

SCALE 1 / 4

CLEANPAKa Nortek Air Solutions Brand

19855 SW 124th AVE.

TUALATIN, OR 97062

Phone (503) 639-0113

www.huntair.com

SIZE:DRAWING NO.:

JOB NO:

DRAWN BY:

ISSUED ON:

CHECKED BY:

SCALE:

THIS DRAWING IS THE

PROPERTY OF

HUNTAIR CLEANPAK

AND CAN NOT BE

REPRODUCED IN

WHOLE OR IN PART,

NOR DELIVERED TO

OTHERS

WITHOUT THE

EXPRESS WRITTEN

PERMISSION OF

HUNTAIR CLEANPAK.

SHEET 46 OF 46

A

TITLE:

2.6 BOTTOM LOAD PLENUM

PLENPAK

Jon H

06/17/14

1/4

2.6BottomLoad.idw

FILE NAME:

5.511

4.906


Recommended