24
CLIMATEMASTER ® COMMERCIAL CONDENSER Manufactured for ClimateMaster ® ClimateMaster.com RACL Nominal Sizes: 6.5, 7.5, 10, 12.5 & 20 Ton [22.9, 26.4, 35.2, 44.0 & 70.3 kW]
Transcript
Page 1: CLIMATEMASTER COMMERCIAL CONDENSER

CLIMATEMASTER® COMMERCIAL CONDENSER

Manufactured for

ClimateMaster® ClimateMaster.com

RACL Nominal Sizes: 6.5, 7.5, 10, 12.5 & 20 Ton [22.9, 26.4, 35.2, 44.0 & 70.3 kW]

Page 2: CLIMATEMASTER COMMERCIAL CONDENSER

Table of Contents RACL

2 ClimateMaster®

TABLE OF CONTENTS

Standard Unit Features ........................................................................................3-4

Model Number Identification ....................................................................................5

Selection Procedure ................................................................................................6

Unit Dimensions ....................................................................................................7-9

Electrical Data/Physical Data..................................................................................10

Performance Data ............................................................................................11-16

General Installation ................................................................................................17

Piping Recommendation ..................................................................................18-19

Sequence of Operation ..........................................................................................20

Limited Warranty ....................................................................................................21

Page 3: CLIMATEMASTER COMMERCIAL CONDENSER

Standard Unit Features RACL

ClimateMaster® 3

• The size ranges offered by ClimateMaster allow you to mix or match components to meet actual job requirements, thus eliminating the need to use oversized or undersized equip-ment. Equipment sized to meet the actual load will provide better operating economy, better humidity control, and longer equipment life.

• With an air cooled system, you have no water or sewer con-nections to make, and no troublesome and costly water treat-ment problems.

• Since the condensing unit is located outside the building, and the low profile air handling unit can be installed in the drop ceiling or in the conditioned space, you will not need a separate equipment room which takes up valuable building space.

• Remote mounting of the already quiet condensing unit keeps the compressor and condenser fan noise outside, and the ver-tical discharge fans carry the sound up and away from the sur-rounding area.

• Because of the simple design of the ClimateMaster remote con-densing unit, installation is quick and simple, and very little maintenance is required.

WHY USE AN AIR COOLED CONDENSING UNIT?

Page 4: CLIMATEMASTER COMMERCIAL CONDENSER

Standard Unit Features RACL

4 ClimateMaster®

FEATURES AND BENEFITS 1. CABINET—All access panels can be opened or removed

without affecting the structural strength of the unit. Stamped louvered panels offer 100% protection for the condenser coil.

2. EQUIPMENT GROUND—Lug for field connection of ground wire.

3. CONTACTOR—The contactor is an electrical switch which operates the compressor and outdoor fans. Its 24 volt coil is activated on a call for cooling or heating.

4. TRANSFORMER—75 VA step-down type, from Line to 24 volts with resetable circuit breaker.

5. AUTO-RESET HIGH PRESSURE CONTROL, AND AUTO-RESET LOW PRESSURE CONTROL—To provide compres-sor protection under abnormally high head pressure condi-tions (outdoor fan failure, restriction, dirty coil, etc.) or abnormally low suction pressure conditions (restrictions, TEV failure, loss of charge, indoor blower failure, etc.) while elimi-nating nuisance tripping sometimes experienced with conven-tional control systems.

6. COIL—Constructed with copper tubes and aluminum fins mechanically bonded to tubes for maximum heat transfer capabilities. All coil assemblies are leak tested up to 550 PSIG (3792 kPa) internal pressure.

7. SERVICE ACCESS—Control box with separate line and con-trol voltages, as well as compressor and other refrigerant con-trols are accessible through access panels. An electrical access cover may be opened or removed without affecting normal operation of the unit. Condenser fan motors are equipped with molded plugs for easy removal. Louver panels and end access panel can be removed for coil cleaning.

8. BASE PAN—Galvanized steel with weather-resistant baked enamel finish.

9. COMPRESSOR—The Scroll Compressor is hermetically sealed with internal high temperature protection, and durable insulation on motor windings. The entire compressor is mounted on rubber grommets to reduce vibration and noise.

10. SUCTION LINE ACCUMULATOR—To prevent liquid slug-ging of compressor.

11. REFRIGERANT CONNECTIONS—All field sweat joints are made external of the unit and are located close to the ground for a neat looking installation

12. SERVICE VALVES—Standard on liquid line and vapor line.

Page 5: CLIMATEMASTER COMMERCIAL CONDENSER

ClimateMaster® 5

R A C L 2 240 C A Z

Z-Scroll Compressor Design Variation A-Standard Electrical Designation C-208-230-3-60 D-460-3-60 078 = 6.5 Tons [22.9 kW] 090 = 7.5 Tons [26.4 kW] 120 = 10 Tons [35.2 kW] 150 = 12.5 Tons [44.0 kW] 240 = 20 Tons [70.3 kW] 2 = Two-Stage Compressor Design Series (R-410A) Type Commercial Remote Condensing Unit ClimateMaster

Model Number Identification RACL

MODEL IDENTIFICATION

[ ] Designates Metric Conversions

Page 6: CLIMATEMASTER COMMERCIAL CONDENSER

6 ClimateMaster®

Selection Procedure RACL

SELECTION PROCEDURE To select an RACL Remote Condensing unit to meet a job requirement, follow this procedure.

1. DETERMINE COOLING AND HEATING REQUIREMENTS AND SPECIFIC OPERATING CONDITIONS FROM PLANS AND SPECS.

Example: *Total cooling capacity— 84,000 BTUH [24.61 kW] *Sensible cooling capacity— 68,000 BTUH [19.92 kW] *Heating capacity— 120,000 BTUH [35.16 kW] *Condenser Entering Air— 95°F [35°C] DB *Evaporator Mixed Air Entering 78°F [26°C] DB; 65°F [18°C] WB *Indoor Air Flow (vertical) 3000 CFM [1416 L/s] *External Static Pressure .5 in. WG *Available Power 240 V, 3 PH

2. SELECT UNIT TO MEET COOLING REQUIREMENTS.

Since total cooling is within the range of a nominal 7.5 ton [26.4 kW] unit, enter cooling performance table at 95°F [35°C] DB condenser inlet air. Interpolate between 63°F [2°C] and 67°F [19°C] to determine total and sensible capacity and power input for 65°F [18°C] WB evap inlet air at 3200 CFM [1510 L/s] indoor air flow (table basis):

Total Capacity = 85,150 BTUH [25.0 kW] Sensible Capacity = 73,850 BTUH [23.0 kW] Power Input (Compressor and Cond. Fans) = 6,750 Watts

Use formula in note ➀ on the cooling performance table to determine sensible capacity at 78°F [26°C] DB evaporator entering air:

Sensible Capacity = 67,250 BTUH [19.7 kW]

3. CORRECT CAPACITIES OF STEP 2 FOR ACTUAL AIR FLOW.

Select factors from airflow correction table at 3000 CFM [1416 L/s] and apply to data obtained in step 2 to obtain gross capacity:

Total Capacity = 85,450 x .99 = 84,595 BTUH [24.8 kW] Sensible Capacity = 73,850 x .97 = 716.34 BTUH [21.0 kW] Power Input = 6,750 x 1.00 = 6,750 Watts

These are Gross Capacities, not corrected for blower motor heat or power.

4. DETERMINE BLOWER SPEED AND WATTS TO MEET SYSTEM DESIGN.

In the “Commercial Air Handler Specification Sheet” follow the bold line example on the “Blower Performance Curve – 10 ton (wet coil)”. Enter the graph at 3000 CFM [1416 L/s]. Determine which “number of turns” line is closest to the intersection of 0.5 IN [.12 kPa] static and 3000 CFM [1416 L/s]. In this case 4 turns is the closest. Continue following the 3000 CFM line to the next intersection of 4 turns. From this intersection draw a line to the right to determine the watts.

WATTS = 950

5. CALCULATE INDOOR BLOWER BTUH HEAT EFFECT FROM MOTOR WATTS, STEP 4.

HEAT = 950 x 3.412 = 3,240 BTUH

6. CALCULATE NET COOLING CAPACITIES, EQUAL TO GROSS CAPACITY, STEP 3, MINUS INDOOR BLOWER MOTOR HEAT.

Net Total Capacity = 85,430 – 3,240 = 82,190 BTUH [24.14 kW] Net Sensible Capacity = 71,634 – 3,240 = 68,394 BTUH [20.00 kW]

7. CALCULATE UNIT INPUT AND JOB EER.

Total Power Input = 7,750 (step 3) + 950 (step 4) = 8,700 Watts

EER = Net Total BTUH [kW] (step 6) = 81,355 = 10.6 Power Input, Watts (above) 7700

8. SELECT UNIT HEATING CAPACITY.

In the “Commercial Air Handler Specification Sheet” turn to the “electrical heater kit characteristics table,” find a heater kit that is com-patible and has minimum of 120,000 BTUH. The RXHE-DE040CA [40 kW] has a capacity of 136,500 BTUH at 240 V.

*NOTE: These operating conditions are typical of a commercial application in a 95°F/79°F [35°C/26°C] design area with indoor design of 76°F [24°C]

DB and 50% RH and 10% ventilation air, with the unit mounted and centered on the zone it conditions by ducts.

[ ] Designates Metric Conversions

Page 7: CLIMATEMASTER COMMERCIAL CONDENSER

ClimateMaster® 7

Unit Dimensions RACL

UNIT DIMENSIONS, IN. [mm]

(-)ACL 2078 2090

Height “H” 51.00 [1295] 51.00 [1295]

Length “L” 35.75 [908] 35.73 [908]

Width “W” 35.75 [908] 35.75 [908]

6.5 & 7.5 TON [22.9 & 26.4 kW]

[ ] Designates Metric Conversions

UNIT DIMENSIONS AND WEIGHTS 6.5 & 7.5 TON [22.9 & 26.4 kW]

Page 8: CLIMATEMASTER COMMERCIAL CONDENSER

8 ClimateMaster®

Unit Dimensions RACL

MODELTOTAL

WEIGHT LBS. [kg]

CORNER WEIGHTS, LBS. [kg]

A B C D

(-)ACL2120 565 [256] 97 [44] 181 [82] 215 [98] 73 [33]

(-)ACL2150 647 [293] 189 [86] 157 [71] 161 [73] 139 [63]

10 & 12.5 TON [35.2 & 44.0 kW]

[ ] Designates Metric Conversions

UNIT DIMENSIONS AND WEIGHTS 10 & 12.5 TON [35.2 & 44.0 kW]

Page 9: CLIMATEMASTER COMMERCIAL CONDENSER

ClimateMaster® 9

Unit Dimensions RACL

IllustrationST-A0890-13

443/4�[1136.6 mm]

383/8�[974.7 mm]

837/8�[2110 mm]

HIGH VOLTAGE 13/4� DIA. HOLELOW VOLTAGE 7/8� DIA. HOLE

LIQUID LINE 5/8� DIA. HOLE

SUCTION LINE 15/8� DIA. HOLE

83/4� [222.2 mm]71/2�

[190.5 mm]

75/16� [198 mm]

111/4� [285.7 mm]

161/4� [412.7 mm]

315/16� [807.6 mm]

285/16� [731.3 mm]

MODELTOTAL

WEIGHT LBS. [kg]

CORNER WEIGHTS, LBS. [kg]

A B C D

(-)ACL2240 926 [420] 308 [140] 128 [58] 161 [73] 328 [149]

20 TON [70.3 kW] CORNER WEIGHTS (LBS.) [kg]

[ ] Designates Metric Conversions

UNIT DIMENSIONS AND WEIGHTS 20 TON [70.3 kW]

RACL2240 (20 TON)

Page 10: CLIMATEMASTER COMMERCIAL CONDENSER

10 ClimateMaster®

Ele

ctri

cal a

nd P

hysi

cal D

ata

Mod

el

Num

ber

(-)A

CL2

EL

EC

TR

ICA

LP

HY

SIC

AL

Phas

e Fr

eque

ncy

(Hz)

Vo

ltage

(Vol

ts)

Num

ber o

f Co

mpr

esso

rs

Com

pres

sor

Num

ber

of F

ans

Fan

Mot

or

Full

Load

Am

pere

s (F

LA)

Com

bine

d

Min

imum

Ci

rcui

t Am

paci

ty

Ampe

res

Fuse

or H

ACR

Circ

uit B

reak

erOu

tdoo

r Coi

lRe

frig.

Pe

r Ci

rcui

t Oz

.

Rate

d Lo

ad

Ampe

res

(RLA

) Co

mbi

ned

Lock

ed R

otor

Am

pere

s (L

RA) C

ombi

ned

Min

imum

Am

pere

sM

axim

um

Ampe

res

Face

Are

a Sq

. Ft.

No.

Row

sCF

M

078C

AZ3-

60-2

08/2

301

28.5

164

14

3845

6032

.44

2 5

700

344

078D

AZ3-

60-4

601

1294

12.

518

2525

32.4

42

570

034

4

090C

AZ3-

60-2

08/2

301

28.5

164

14

3845

6032

.44

2 5

700

344

090D

AZ3-

60-4

601

1294

12.

518

2525

32.4

42

570

034

4

120C

AZ3-

60-2

08/2

301

34.8

240

27.

849

6080

32.8

82

800

042

2

120D

AZ3-

60-4

601

14.8

130

25

2430

3532

.88

2 8

000

422

150C

AZ3-

60-2

08/2

302*

34.5

274

29.

453

7080

40.3

82

1140

041

4

150D

AZ3-

60-4

602*

19.4

152

25

3035

4540

.38

211

400

414

180C

AZ3-

60-2

08/2

302*

4137

63

15.9

6880

100

40.3

83

1200

058

2

180D

AZ3-

60-4

602*

23.2

196

315

.937

4550

40.3

83

1200

058

2

240C

AZ3-

60-2

08/2

302*

34.1

480

315

.959

7090

40.3

83

1200

065

0

240D

AZ3-

60-4

602*

32.1

280

37.

548

6070

40.3

83

1200

065

0

*Tan

dem

[ ]

Des

igna

tes

Met

ric

Co

nver

sio

ns

Electrical/Physical Data RACL

Page 11: CLIMATEMASTER COMMERCIAL CONDENSER

Performance Data RACL

ClimateMaster® 11

MODEL NUMBERS 80°F [26.5°C] DB 67°F [19.5°C] WB INDOOR AIR 95°F [35°C] DB OUTDOOR AIRRATED

INDOOR CFM [L/s]

OUTDOOR UNIT RACL-

INDOOR COIL AND/OR

AIR HANDLER

TOTAL CAPACITY

BTU/H [kW]

NET SENSIBLE BTU/H [kW]

NET LATENT BTU/H [kW] EER IEER

RACL2078 RHCLA2090 78000 [22.8] 54400 [15.9] 23600 [6.9] 11.2 12.9 2800

RACL2090 RHCLA2090 88000 [25.8] 62000 [18.2] 26000 [7.6] 11.2 12.9 2800

RACL2120 RHCLA2120 114000 [33.4] 83600 [24.5] 30400 [8.9] 11.2 12.9 3660

RACL2150 RHCLA2150 142000 [41.6] 108800 [31.9] 33200 [9.7] 11.0 12.4 4780

RACL2240 RHCLA2240 240000 [70.3] 163500 [47.9] 76500 [22.4] 10.0 11.6 7200

PERFORMANCE DATA @ AHRI STANDARD CONDITIONS

Page 12: CLIMATEMASTER COMMERCIAL CONDENSER

12 ClimateMaster®

ENTE

RING

INDO

OR A

IR @

80°

F [2

6.7°

C] d

bE ➀

wbE

71°F

[21.

7°C]

67°F

[19.

4°C]

63°F

[17.

2°C]

61°F

[16.

1°C]

59°F

[15.

0°C]

CFM

[L/s

]31

50 [1

487]

2700

[127

4]21

00 [9

91]

3150

[148

7]27

00 [1

274]

2100

[991

]31

50 [1

487]

2700

[127

4]21

00 [9

91]

3150

[148

7]27

00 [1

274]

2100

[991

]31

50 [1

487]

2700

[127

4]21

00 [9

91]

DR ➀

0.16

0.13

0.08

0.16

0.13

0.08

0.16

0.13

0.08

0.16

0.13

0.08

0.16

0.13

0.08

O

U

T

D

O

O

R D

R

Y B

U

L B T

E

M

P

E

R

A

T

U

R

E

75° F

[2

3.9]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

98.1

[28.

7]

61.1

[17.

9]

6.4

95.2

[27.

9]

56.7

[16.

6]

6.3

91.3

[26.

8]

50.8

[14.

9]

6.1

92.2

[27.

0]

73.5

[21.

5]

6.4

89.5

[26.

2]

68.2

[20.

0]

6.3

85.9

[25.

2]

61.1

[17.

9]

6.2

86.2

[25.

3]

84.1

[24.

6]

6.4

83.6

[24.

5]

78.0

[22.

9]

6.3

80.3

[23.

5]

69.9

[20.

5]

6.2

83.2

[24.

4]

83.2

[24.

4]

6.4

80.7

[23.

7]

80.7

[23.

7]

6.3

77.5

[22.

7]

73.5

[21.

5]

6.2

80.2

[23.

5]

80.2

[23.

5]

6.4

77.8

[22.

8]

77.8

[22.

8]

6.3

74.7

[21.

9]

74.7

[21.

9]

6.2

80° F

[2

6.7]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

95.9

[28.

1]

60.2

[17.

6]

6.3

93.1

[27.

3]

55.8

[16.

4]

6.3

89.3

[26.

2]

50.0

[14.

7]

6.1

90.0

[26.

4]

72.5

[21.

2]

6.4

87.3

[25.

6]

67.3

[19.

7]

6.3

83.8

[24.

6]

60.3

[17.

7]

6.2

84.0

[24.

6]

83.1

[24.

3]

6.4

81.5

[23.

9]

77.1

[22.

6]

6.3

78.2

[22.

9]

69.1

[20.

2]

6.2

81.0

[23.

7]

81.0

[23.

7]

6.4

78.6

[23.

0]

78.6

[23.

0]

6.3

75.4

[22.

1]

72.7

[21.

3]

6.2

78.0

[22.

9]

78.0

[22.

9]

6.4

75.7

[22.

2]

75.7

[22.

2]

6.3

72.6

[21.

3]

72.6

[21.

3]

6.2

85° F

[2

9.4]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

93.5

[27.

4]

58.5

[17.

1]

6.3

90.8

[26.

6]

54.3

[15.

9]

6.3

87.1

[25.

5]

48.6

[14.

2]

6.1

87.6

[25.

7]

70.8

[20.

8]

6.4

85.1

[24.

9]

65.7

[19.

3]

6.3

81.6

[23.

9]

58.9

[17.

3]

6.1

81.6

[23.

9]

81.4

[23.

8]

6.4

79.2

[23.

2]

75.5

[22.

1]

6.3

76.0

[22.

3]

67.7

[19.

8]

6.2

78.6

[23.

0]

78.6

[23.

0]

6.4

76.3

[22.

4]

76.3

[22.

4]

6.3

73.2

[21.

5]

71.3

[20.

9]

6.2

75.6

[22.

2]

75.6

[22.

2]

6.4

73.4

[21.

5]

73.4

[21.

5]

6.3

70.5

[20.

6]

70.5

[20.

6]

6.2

90° F

[3

2.2]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

91.0

[26.

7]

56.1

[16.

4]

6.3

88.4

[25.

9]

52.1

[15.

3]

6.3

84.8

[24.

8]

46.7

[13.

7]

6.1

85.2

[25.

0]

68.4

[20.

1]

6.4

82.7

[24.

2]

63.5

[18.

6]

6.3

79.3

[23.

2]

56.9

[16.

7]

6.1

79.2

[23.

2]

79.0

[23.

2]

6.4

76.8

[22.

5]

73.3

[21.

5]

6.3

73.7

[21.

6]

65.7

[19.

3]

6.2

76.1

[22.

3]

76.1

[22.

3]

6.4

73.9

[21.

7]

73.9

[21.

7]

6.3

70.9

[20.

8]

69.3

[20.

3]

6.2

73.2

[21.

4]

73.2

[21.

4]

6.4

71.0

[20.

8]

71.0

[20.

8]

6.3

68.1

[20.

0]

68.1

[20.

0]

6.2

95° F

[3

5]° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

88.4

[25.

9]

53.1

[15.

6]

6.3

85.8

[25.

1]

49.2

[14.

4]

6.2

82.3

[24.

1]

44.1

[12.

9]

6.1

82.5

[24.

2]

65.4

[19.

2]

6.4

80.1

[23.

5]

60.7

[17.

8]

6.3

76.8

[22.

5]

54.4

[15.

9]

6.1

76.5

[22.

4]

76.0

[22.

3]

6.4

74.3

[21.

8]

70.5

[20.

7]

6.3

71.3

[20.

9]

63.2

[18.

5]

6.2

73.5

[21.

5]

73.5

[21.

5]

6.4

71.3

[20.

9]

71.3

[20.

9]

6.3

68.5

[20.

1]

66.8

[19.

6]

6.2

70.5

[20.

7]

70.5

[20.

7]

6.4

68.4

[20.

1]

68.4

[20.

1]

6.3

65.7

[19.

2]

65.7

[19.

2]

6.2

100°

F [3

7.8]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

85.6

[25.

1]

49.3

[14.

5]

6.3

83.1

[24.

3]

45.8

[13.

4]

6.2

79.7

[23.

4]

41.0

[12.

0]

6.1

79.7

[23.

4]

61.7

[18.

1]

6.4

77.4

[22.

7]

57.2

[16.

8]

6.3

74.2

[21.

8]

51.3

[15.

0]

6.1

73.7

[21.

6]

72.2

[21.

2]

6.4

71.5

[21.

0]

67.0

[19.

6]

6.3

68.6

[20.

1]

60.1

[17.

6]

6.2

70.7

[20.

7]

70.7

[20.

7]

6.4

68.6

[20.

1]

68.6

[20.

1]

6.3

65.8

[19.

3]

63.7

[18.

7]

6.2

67.7

[19.

8]

67.7

[19.

8]

6.4

65.7

[19.

3]

65.7

[19.

3]

6.3

63.1

[18.

5]

63.1

[18.

5]

6.2

105°

F [4

0.6]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

82.6

[24.

2]

44.9

[13.

2]

6.3

80.2

[23.

5]

41.7

[12.

2]

6.2

77.0

[22.

6]

37.4

[10.

9]

6.1

76.8

[22.

5]

57.3

[16.

8]

6.4

74.5

[21.

8]

53.1

[15.

6]

6.3

71.5

[20.

9]

47.6

[14.

0]

6.1

70.7

[20.

7]

67.8

[19.

9]

6.4

68.7

[20.

1]

62.9

[18.

4]

6.3

65.9

[19.

3]

56.4

[16.

5]

6.2

67.7

[19.

9]

67.7

[19.

9]

6.4

65.7

[19.

3]

65.7

[19.

3]

6.3

63.1

[18.

5]

60.0

[17.

6]

6.2

64.7

[19.

0]

64.7

[19.

0]

6.4

62.8

[18.

4]

62.8

[18.

4]

6.3

60.3

[17.

7]

60.3

[17.

7]

6.2

110°

F [4

3.3]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

79.5

[23.

3]

39.8

[11.

7]

6.3

77.2

[22.

6]

36.9

[10.

8]

6.2

74.1

[21.

7]

33.1

[9

.7]

6.1

73.6

[21.

6]

52.2

[15.

3]

6.3

71.5

[20.

9]

48.4

[14.

2]

6.3

68.6

[20.

1]

43.4

[12.

7]

6.1

67.6

[19.

8]

62.7

[18.

4]

6.4

65.7

[19.

2]

58.2

[17.

1]

6.3

63.0

[18.

5]

52.2

[15.

3]

6.2

64.6

[18.

9]

64.6

[18.

9]

6.4

62.7

[18.

4]

62.2

[18.

2]

6.3

60.2

[17.

6]

55.8

[16.

3]

6.2

61.6

[18.

1]

61.6

[18.

1]

6.4

59.8

[17.

5]

59.8

[17.

5]

6.3

57.4

[16.

8]

57.4

[16.

8]

6.2

115°

F [4

6.1]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

76.3

[22.

3]

34.0

[10.

0]

6.3

74.0

[21.

7]

31.6

[9

.3]

6.2

71.0

[20.

8]

28.3

[8

.3]

6.1

70.4

[20.

6]

46.4

[13.

6]

6.3

68.3

[20.

0]

43.0

[12.

6]

6.3

65.5

[19.

2]

38.6

[11.

3]

6.1

64.4

[18.

9]

57.0

[16.

7]

6.4

62.5

[18.

3]

52.8

[15.

5]

6.3

60.0

[17.

6]

47.4

[13.

9]

6.1

61.4

[18.

0]

61.3

[18.

0]

6.4

59.6

[17.

5]

56.8

[16.

7]

6.3

57.2

[16.

7]

50.9

[14.

9]

6.2

58.4

[17.

1]

58.4

[17.

1]

6.4

56.7

[16.

6]

56.7

[16.

6]

6.3

54.4

[15.

9]

53.8

[15.

8]

6.2

120°

F [4

8.9]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

72.9

[21.

3]

27.6

[8

.1]

6.3

70.7

[20.

7]

25.6

[7

.5]

6.2

67.9

[19.

9]

22.9

[6

.7]

6.1

67.0

[19.

6]

39.9

[11.

7]

6.3

65.0

[19.

0]

37.0

[10.

8]

6.3

62.4

[18.

3]

33.2

[9

.7]

6.1

61.0

[17.

9]

50.5

[14.

8]

6.4

59.2

[17.

3]

46.8

[13.

7]

6.3

56.8

[16.

6]

42.0

[12.

3]

6.1

57.9

[17.

0]

54.8

[16.

1]

6.4

56.2

[16.

5]

50.8

[14.

9]

6.3

54.0

[15.

8]

45.6

[13.

4]

6.2

55.0

[16.

1]

55.0

[16.

1]

6.4

53.3

[15.

6]

53.3

[15.

6]

6.3

51.2

[15.

0]

48.4

[14.

2]

6.2

125°

F [5

1.7]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

69.3

[20.

3]

20.4

[6

.0]

6.3

67.2

[19.

7]

18.9

[5

.6]

6.2

64.5

[18.

9]

17.0

[5

.0]

6.1

63.4

[18.

6]

32.8

[9

.6]

6.3

61.5

[18.

0]

30.4

[8

.9]

6.2

59.0

[17.

3]

27.2

[8

.0]

6.1

57.4

[16.

8]

43.3

[12.

7]

6.4

55.7

[16.

3]

40.2

[11.

8]

6.3

53.5

[15.

7]

36.0

[10.

6]

6.1

54.4

[15.

9]

47.6

[14.

0]

6.4

52.8

[15.

5]

44.2

[13.

0]

6.3

50.6

[14.

8]

39.6

[11.

6]

6.2

51.4

[15.

1]

51.1

[15.

0]

6.4

49.9

[14.

6]

47.4

[13.

9]

6.3

47.9

[14.

0]

42.5

[12.

4]

6.2

Performance Data RACL

CO

OLI

NG

PE

RFO

RM

AN

CE

DAT

A—

RA

CL2

078+

RH

CLA

2090

NOTE

S:

➀W

hen

the

ente

ring

air d

ry b

ulb

is o

ther

than

80°

F [2

7°C]

, adj

ust t

he s

ensi

ble

capa

city

fro

m th

e ta

ble

by a

ddin

g [1

.10

x CF

M x

(1 –

DR)

x (d

bE –

80)

].

DR —

Depr

essi

on ra

tio

dbE

—En

terin

g ai

r dry

bul

b w

bE—

Ente

ring

air w

et b

ulb

Tota

l —

Tota

l cap

acity

x 1

000

BTUH

Se

ns —

Sens

ible

cap

acity

x 1

000

BTUH

Po

wer

—KW

inpu

t

[ ]

Des

igna

tes

Met

ric

Co

nver

sio

ns

Page 13: CLIMATEMASTER COMMERCIAL CONDENSER

ClimateMaster® 13

ENTE

RING

INDO

OR A

IR @

80°

F [2

6.7°

C] d

bE ➀

wbE

71°F

[21.

7°C]

67°F

[19.

4°C]

63°F

[17.

2°C]

61°F

[16.

1°C]

59°F

[15.

0°C]

CFM

[L/s

]32

40 [1

529]

2700

[127

4]21

60 [1

019]

3240

[152

9]27

00 [1

274]

2160

[101

9]32

40 [1

529]

2700

[127

4]21

60 [1

019]

3240

[152

9]27

00 [1

274]

2160

[101

9]32

40 [1

529]

2700

[127

4]21

60 [1

019]

DR ➀

0.07

0.03

-0.0

20.

070.

03-0

.02

0.07

0.03

-0.0

20.

070.

03-0

.02

0.07

0.03

-0.0

2

O

U

T

D

O

O

R D

R

Y B

U

L B T

E

M

P

E

R

A

T

U

R

E

75° F

[2

3.9]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

109.

6 [3

2.1]

7

0.3

[20.

6]

7.5

105.

8 [3

1.0]

6

4.3

[18.

8]

7.3

101.

9 [2

9.9]

5

8.3

[17.

1]

7.2

103.

6 [3

0.3]

8

3.1

[24.

4]

7.5

99.9

[29.

3]

76.0

[22.

3]

7.4

96.3

[28.

2]

68.9

[20.

2]

7.2

97.4

[28.

5]

94.0

[27.

6]

7.5

94.0

[27.

5]

86.0

[25.

2]

7.4

90.6

[26.

5]

78.0

[22.

9]

7.2

94.3

[27.

6]

94.3

[27.

6]

7.5

91.0

[26.

7]

90.1

[26.

4]

7.4

87.7

[25.

7]

81.7

[23.

9]

7.3

91.2

[26.

7]

91.2

[26.

7]

7.5

88.0

[25.

8]

88.0

[25.

8]

7.4

84.8

[24.

9]

84.6

[24.

8]

7.3

80° F

[2

6.7]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

107.

4 [3

1.5]

6

9.3

[20.

3]

7.5

103.

6 [3

0.4]

6

3.4

[18.

6]

7.3

99.

8 [2

9.3]

5

7.5

[16.

8]

7.2

101.

3 [2

9.7]

8

2.1

[24.

0]

7.5

97.8

[28.

6]

75.1

[22.

0]

7.4

94.2

[27.

6]

68.1

[19.

9]

7.2

95.2

[27.

9]

93.0

[27.

3]

7.5

91.8

[26.

9]

85.1

[24.

9]

7.4

88.5

[25.

9]

77.1

[22.

6]

7.2

92.1

[27.

0]

92.1

[27.

0]

7.5

88.8

[26.

0]

88.8

[26.

0]

7.4

85.6

[25.

1]

80.8

[23.

7]

7.3

89.0

[26.

1]

89.0

[26.

1]

7.5

85.9

[25.

2]

85.9

[25.

2]

7.4

82.8

[24.

3]

82.8

[24.

3]

7.3

85° F

[2

9.4]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

105.

0 [3

0.8]

6

7.6

[19.

8]

7.5

101.

3 [2

9.7]

6

1.8

[18.

1]

7.3

97.

6 [2

8.6]

5

6.0

[16.

4]

7.2

98.

9 [2

9.0]

8

0.3

[23.

5]

7.5

95.4

[28.

0]

73.5

[21.

5]

7.4

92.0

[27.

0]

66.6

[19.

5]

7.2

92.8

[27.

2]

91.3

[26.

7]

7.5

89.5

[26.

2]

83.5

[24.

5]

7.4

86.2

[25.

3]

75.7

[22.

2]

7.2

89.7

[26.

3]

89.7

[26.

3]

7.5

86.5

[25.

4]

86.5

[25.

4]

7.4

83.4

[24.

4]

79.4

[23.

3]

7.2

86.6

[25.

4]

86.6

[25.

4]

7.5

83.6

[24.

5]

83.6

[24.

5]

7.4

80.5

[23.

6]

80.5

[23.

6]

7.3

90° F

[3

2.2]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

102.

4 [3

0.0]

6

5.1

[19.

1]

7.5

98.

8 [2

9.0]

5

9.6

[17.

5]

7.3

95.

2 [2

7.9]

5

4.0

[15.

8]

7.2

96.

4 [2

8.2]

7

7.9

[22.

8]

7.5

93.0

[27.

2]

71.2

[20.

9]

7.3

89.6

[26.

3]

64.6

[18.

9]

7.2

90.2

[26.

4]

88.8

[26.

0]

7.5

87.0

[25.

5]

81.3

[23.

8]

7.4

83.9

[24.

6]

73.7

[21.

6]

7.2

87.1

[25.

5]

87.1

[25.

5]

7.5

84.1

[24.

6]

84.1

[24.

6]

7.4

81.0

[23.

7]

77.4

[22.

7]

7.2

84.0

[24.

6]

84.0

[24.

6]

7.5

81.1

[23.

8]

81.1

[23.

8]

7.4

78.1

[22.

9]

78.1

[22.

9]

7.3

95° F

[3

5]° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

99.

7 [2

9.2]

6

2.0

[18.

2]

7.5

96.

2 [2

8.2]

5

6.7

[16.

6]

7.3

92.

7 [2

7.2]

5

1.4

[15.

1]

7.2

93.

6 [2

7.4]

7

4.7

[21.

9]

7.5

90.4

[26.

5]

68.4

[20.

0]

7.3

87.1

[25.

5]

62.0

[18.

2]

7.2

87.5

[25.

6]

85.7

[25.

1]

7.5

84.4

[24.

7]

78.4

[23.

0]

7.4

81.3

[23.

8]

71.1

[20.

8]

7.2

84.4

[24.

7]

84.4

[24.

7]

7.5

81.4

[23.

9]

81.4

[23.

9]

7.4

78.5

[23.

0]

74.8

[21.

9]

7.2

81.3

[23.

8]

81.3

[23.

8]

7.5

78.5

[23.

0]

78.5

[23.

0]

7.4

75.6

[22.

2]

75.6

[22.

2]

7.3

100°

F [3

7.8]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

96.

8 [2

8.4]

5

8.1

[17.

0]

7.5

93.

4 [2

7.4]

5

3.1

[15.

6]

7.3

90.

0 [2

6.4]

4

8.2

[14.

1]

7.2

90.

8 [2

6.6]

7

0.9

[20.

8]

7.5

87.6

[25.

7]

64.8

[19.

0]

7.3

84.4

[24.

7]

58.8

[17.

2]

7.2

84.6

[24.

8]

81.8

[24.

0]

7.5

81.6

[23.

9]

74.8

[21.

9]

7.4

78.7

[23.

1]

67.9

[19.

9]

7.2

81.5

[23.

9]

81.5

[23.

9]

7.5

78.7

[23.

0]

78.7

[23.

0]

7.4

75.8

[22.

2]

71.6

[21.

0]

7.2

78.4

[23.

0]

78.4

[23.

0]

7.5

75.7

[22.

2]

75.7

[22.

2]

7.4

72.9

[21.

4]

72.9

[21.

4]

7.2

105°

F [4

0.6]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

93.

8 [2

7.5]

5

3.5

[15.

7]

7.5

90.

5 [2

6.5]

4

9.0

[14.

3]

7.3

87.

2 [2

5.6]

4

4.4

[13.

0]

7.2

87.

7 [2

5.7]

6

6.3

[19.

4]

7.5

84.7

[24.

8]

60.6

[17.

8]

7.3

81.6

[23.

9]

55.0

[16.

1]

7.2

81.6

[23.

9]

77.3

[22.

6]

7.5

78.7

[23.

1]

70.7

[20.

7]

7.4

75.8

[22.

2]

64.1

[18.

8]

7.2

78.5

[23.

0]

78.5

[23.

0]

7.5

75.7

[22.

2]

74.7

[21.

9]

7.4

73.0

[21.

4]

67.8

[19.

9]

7.2

75.4

[22.

1]

75.4

[22.

1]

7.5

72.8

[21.

3]

72.8

[21.

3]

7.4

70.1

[20.

5]

70.1

[20.

5]

7.2

110°

F [4

3.3]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

90.

6 [2

6.5]

4

8.3

[14.

1]

7.4

87.

4 [2

5.6]

4

4.1

[12.

9]

7.3

84.

2 [2

4.7]

4

0.0

[11.

7]

7.2

84.

5 [2

4.8]

6

1.0

[17.

9]

7.5

81.6

[23.

9]

55.8

[16.

4]

7.3

78.6

[23.

0]

50.6

[14.

8]

7.2

78.4

[23.

0]

72.0

[21.

1]

7.5

75.6

[22.

2]

65.8

[19.

3]

7.4

72.9

[21.

4]

59.7

[17.

5]

7.2

75.3

[22.

1]

75.3

[22.

1]

7.5

72.6

[21.

3]

69.9

[20.

5]

7.4

70.0

[20.

5]

63.4

[18.

6]

7.2

72.2

[21.

2]

72.2

[21.

2]

7.5

69.7

[20.

4]

69.7

[20.

4]

7.4

67.2

[19.

7]

66.3

[19.

4]

7.2

115°

F [4

6.1]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

87.

2 [2

5.6]

4

2.3

[12.

4]

7.4

84.

2 [2

4.7]

3

8.7

[11.

3]

7.3

81.

1 [2

3.8]

3

5.1

[10.

3]

7.2

81.

2 [2

3.8]

5

5.0

[16.

1]

7.5

78.3

[23.

0]

50.3

[14.

8]

7.3

75.5

[22.

1]

45.6

[13.

4]

7.2

75.0

[22.

0]

66.0

[19.

3]

7.5

72.4

[21.

2]

60.4

[17.

7]

7.4

69.8

[20.

4]

54.7

[16.

0]

7.2

71.9

[21.

1]

70.4

[20.

6]

7.5

69.4

[20.

3]

64.4

[18.

9]

7.4

66.9

[19.

6]

58.4

[17.

1]

7.2

68.9

[20.

2]

68.9

[20.

2]

7.5

66.5

[19.

5]

66.5

[19.

5]

7.4

64.0

[18.

8]

61.4

[18.

0]

7.2

120°

F [4

8.9]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

83.

7 [2

4.5]

3

5.6

[10.

4]

7.4

80.

8 [2

3.7]

3

2.5

[9.

5]

7.3

77.

9 [2

2.8]

2

9.5

[8.

6]

7.2

77.

7 [2

2.8]

4

8.3

[14.

2]

7.5

75.0

[22.

0]

44.2

[13.

0]

7.3

72.2

[21.

2]

40.1

[11.

7]

7.2

71.5

[21.

0]

59.3

[17.

4]

7.5

69.0

[20.

2]

54.2

[15.

9]

7.3

66.5

[19.

5]

49.2

[14.

4]

7.2

68.4

[20.

1]

63.8

[18.

7]

7.5

66.0

[19.

4]

58.3

[17.

1]

7.4

63.6

[18.

6]

52.9

[15.

5]

7.2

65.4

[19.

2]

65.4

[19.

2]

7.5

63.1

[18.

5]

61.6

[18.

0]

7.4

60.8

[17.

8]

55.8

[16.

4]

7.2

125°

F [5

1.7]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

80.

1 [2

3.5]

2

8.2

[8.

3]

7.4

77.

3 [2

2.6]

2

5.8

[7.

6]

7.3

74.

4 [2

1.8]

2

3.4

[6.

8]

7.2

74.

0 [2

1.7]

4

0.9

[12.

0]

7.5

71.4

[20.

9]

37.4

[11.

0]

7.3

68.8

[20.

2]

33.9

[9

.9]

7.2

67.9

[19.

9]

51.9

[15.

2]

7.5

65.5

[19.

2]

47.5

[13.

9]

7.3

63.1

[18.

5]

43.0

[12.

6]

7.2

64.8

[19.

0]

56.3

[16.

5]

7.5

62.5

[18.

3]

51.5

[15.

1]

7.4

60.2

[17.

6]

46.7

[13.

7]

7.2

61.7

[18.

1]

59.9

[17.

6]

7.5

59.5

[17.

4]

54.8

[16.

1]

7.4

57.4

[16.

8]

49.7

[14.

6]

7.2

Performance Data RACL

CO

OLI

NG

PE

RFO

RM

AN

CE

DAT

A—

RA

CL2

090+

RH

CLA

2090

NOTE

S:

➀W

hen

the

ente

ring

air d

ry b

ulb

is o

ther

than

80°

F [2

7°C]

, adj

ust t

he s

ensi

ble

capa

city

fro

m th

e ta

ble

by a

ddin

g [1

.10

x CF

M x

(1 –

DR)

x (d

bE –

80)

].

DR —

Depr

essi

on ra

tio

dbE

—En

terin

g ai

r dry

bul

b w

bE—

Ente

ring

air w

et b

ulb

Tota

l —

Tota

l cap

acity

x 1

000

BTUH

Se

ns —

Sens

ible

cap

acity

x 1

000

BTUH

Po

wer

—KW

inpu

t

[ ]

Des

igna

tes

Met

ric

Co

nver

sio

ns

Page 14: CLIMATEMASTER COMMERCIAL CONDENSER

14 ClimateMaster®

ENTE

RING

INDO

OR A

IR @

80°

F [2

6.7°

C] d

bE ➀

wbE

71°F

[21.

7°C]

67°F

[19.

4°C]

63°F

[17.

2°C]

61°F

[16.

1°C]

59°F

[15.

0°C]

CFM

[L/s

]45

60 [2

152]

3400

[160

5]30

40 [1

435]

4560

[215

2]34

00 [1

605]

3040

[143

5]45

60 [2

152]

3400

[160

5]30

40 [1

435]

4560

[215

2]34

00 [1

605]

3040

[143

5]45

60 [2

152]

3400

[160

5]30

40 [1

435]

DR ➀

0.08

0.02

-0.0

10.

080.

02-0

.01

0.08

0.02

-0.0

10.

080.

02-0

.01

0.08

0.02

-0.0

1

O

U

T

D

O

O

R D

R

Y B

U

L B T

E

M

P

E

R

A

T

U

R

E

75° F

[2

3.9]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

145.

0 [4

2.5]

9

0.4

[26.

5]

8.0

136.

5 [4

0.0]

7

8.0

[22.

9]

7.8

133.

9 [3

9.2]

7

4.1

[21.

7]

7.7

135.

1 [3

9.6]

10

6.6

[31.

2]

8.0

127.

2 [3

7.3]

9

2.0

[27.

0]

7.7

124.

8 [3

6.6]

8

7.4

[25.

6]

7.6

124.

8 [3

6.6]

11

7.8

[34.

5]

7.9

117.

5 [3

4.4]

10

1.6

[29.

8]

7.7

115.

3 [3

3.8]

9

6.6

[28.

3]

7.6

119.

6 [3

5.0]

11

9.6

[35.

0]

7.8

112.

6 [3

3.0]

10

4.0

[30.

5]

7.6

110.

4 [3

2.4]

9

8.9

[29.

0]

7.5

114.

2 [3

3.5]

11

4.2

[33.

5]

7.8

107.

6 [3

1.5]

10

4.4

[30.

6]

7.6

105.

5 [3

0.9]

9

9.3

[29.

1]

7.5

80° F

[2

6.7]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

142.

6 [4

1.8]

8

9.4

[26.

2]

8.4

134.

3 [3

9.4]

7

7.1

[22.

6]

8.1

131.

7 [3

8.6]

7

3.3

[21.

5]

8.1

132.

7 [3

8.9]

10

5.6

[31.

0]

8.3

125.

0 [3

6.6]

9

1.1

[26.

7]

8.1

122.

6 [3

5.9]

8

6.6

[25.

4]

8.0

122.

5 [3

5.9]

11

6.8

[34.

2]

8.2

115.

3 [3

3.8]

10

0.7

[29.

5]

8.0

113.

1 [3

3.1]

9

5.7

[28.

1]

7.9

117.

2 [3

4.3]

11

7.2

[34.

3]

8.2

110.

4 [3

2.3]

10

3.2

[30.

2]

8.0

108.

2 [3

1.7]

9

8.1

[28.

7]

7.9

111.

9 [3

2.8]

11

1.9

[32.

8]

8.2

105.

3 [3

0.9]

10

3.6

[30.

3]

7.9

103.

3 [3

0.3]

9

8.4

[28.

8]

7.9

85° F

[2

9.4]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

140.

0 [4

1.0]

8

8.3

[25.

9]

8.8

131.

8 [3

8.6]

7

6.2

[22.

3]

8.5

129.

3 [3

7.9]

7

2.4

[21.

2]

8.4

130.

1 [3

8.1]

10

4.5

[30.

6]

8.7

122.

5 [3

5.9]

9

0.2

[26.

4]

8.5

120.

1 [3

5.2]

8

5.7

[25.

1]

8.4

119.

8 [3

5.1]

11

5.6

[33.

9]

8.6

112.

8 [3

3.1]

9

9.8

[29.

2]

8.4

110.

7 [3

2.4]

9

4.8

[27.

8]

8.3

114.

6 [3

3.6]

11

4.6

[33.

6]

8.6

107.

9 [3

1.6]

10

2.2

[30.

0]

8.4

105.

8 [3

1.0]

9

7.2

[28.

5]

8.3

109.

2 [3

2.0]

10

9.2

[32.

0]

8.6

102.

8 [3

0.1]

10

2.6

[30.

1]

8.3

100.

9 [2

9.6]

9

7.5

[28.

6]

8.2

90° F

[3

2.2]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

137.

1 [4

0.2]

8

7.1

[25.

5]

9.2

129.

1 [3

7.8]

7

5.1

[22.

0]

8.9

126.

6 [3

7.1]

7

1.4

[20.

9]

8.9

127.

2 [3

7.3]

10

3.3

[30.

3]

9.1

119.

8 [3

5.1]

8

9.1

[26.

1]

8.9

117.

5 [3

4.4]

8

4.7

[24.

8]

8.8

116.

9 [3

4.3]

11

4.4

[33.

5]

9.1

110.

1 [3

2.3]

9

8.7

[28.

9]

8.8

108.

0 [3

1.6]

9

3.8

[27.

5]

8.7

111.

7 [3

2.7]

11

1.7

[32.

7]

9.0

105.

2 [3

0.8]

10

1.1

[29.

6]

8.8

103.

1 [3

0.2]

9

6.1

[28.

2]

8.7

106.

3 [3

1.2]

10

6.3

[31.

2]

9.0

100.

1 [2

9.3]

10

0.1

[29.

3]

8.7

98.

2 [2

8.8]

9

6.5

[28.

3]

8.7

95° F

[3

5]° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

134.

0 [3

9.3]

8

5.7

[25.

1]

9.7

126.

2 [3

7.0]

7

3.9

[21.

7]

9.4

123.

7 [3

6.3]

7

0.3

[20.

6]

9.3

124.

1 [3

6.4]

10

1.9

[29.

9]

9.6

116.

8 [3

4.2]

8

7.9

[25.

8]

9.3

114.

6 [3

3.6]

8

3.6

[24.

5]

9.2

113.

8 [3

3.4]

11

3.0

[33.

1]

9.5

107.

2 [3

1.4]

9

7.5

[28.

6]

9.3

105.

1 [3

0.8]

9

2.7

[27.

2]

9.2

108.

5 [3

1.8]

10

8.5

[31.

8]

9.5

102.

2 [3

0.0]

10

0.0

[29.

3]

9.2

100.

2 [2

9.4]

9

5.0

[27.

8]

9.1

103.

2 [3

0.2]

10

3.2

[30.

2]

9.5

97.

2 [2

8.5]

9

7.2

[28.

5]

9.2

95.

3 [2

7.9]

9

5.3

[27.

9]

9.1

100°

F [3

7.8]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

130.

6 [3

8.3]

84

.2 [2

4.7]

10

.2

123.

0 [3

6.0]

7

2.6

[21.

3]

9.9

120.

6 [3

5.3]

6

9.0

[20.

2]

9.8

120.

7 [3

5.4]

10

0.4

[29.

4]

10.1

113.

6 [3

3.3]

86

.6 [2

5.4]

9.

8

111.

4 [3

2.7]

8

2.4

[24.

1]

9.7

110.

4 [3

2.4]

11

0.4

[32.

4]

10.0

104.

0 [3

0.5]

9

6.2

[28.

2]

9.7

102.

0 [2

9.9]

9

1.5

[26.

8]

9.6

105.

2 [3

0.8]

10

5.2

[30.

8]

10.0

99.

0 [2

9.0]

9

8.7

[28.

9]

9.7

97.

1 [2

8.5]

9

3.8

[27.

5]

9.6

99.

8 [2

9.2]

9

9.8

[29.

2]

10.0

94.

0 [2

7.5]

9

4.0

[27.

5]

9.7

92.

2 [2

7.0]

9

2.2

[27.

0]

9.6

105°

F [4

0.6]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

126.

9 [3

7.2]

8

2.6

[24.

2]

10.7

119.

5 [3

5.0]

7

1.2

[20.

9]

10.4

117.

2 [3

4.4]

6

7.7

[19.

8]

10.3

117.

0 [3

4.3]

9

8.8

[29.

0]

10.6

110.

2 [3

2.3]

8

5.2

[25.

0]

10.3

108.

1 [3

1.7]

8

1.0

[23.

7]

10.2

106.

8 [3

1.3]

10

6.8

[31.

3]

10.6

100.

5 [2

9.5]

9

4.8

[27.

8]

10.3

98.

6 [2

8.9]

9

0.2

[26.

4]

10.2

101.

5 [2

9.7]

10

1.5

[29.

7]

10.5

95.

6 [2

8.0]

9

5.6

[28.

0]

10.2

93.

7 [2

7.5]

9

2.5

[27.

1]

10.1

96.

2 [2

8.2]

9

6.2

[28.

2]

10.5

90.

5 [2

6.5]

9

0.5

[26.

5]

10.2

88.

8 [2

6.0]

8

8.8

[26.

0]

10.1

110°

F [4

3.3]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

123.

0 [3

6.1]

8

0.8

[23.

7]

11.3

115.

9 [3

3.9]

6

9.7

[20.

4]

10.9

113.

6 [3

3.3]

6

6.3

[19.

4]

10.8

113.

1 [3

3.2]

9

7.1

[28.

4]

11.2

106.

5 [3

1.2]

8

3.7

[24.

5]

10.9

104.

5 [3

0.6]

7

9.6

[23.

3]

10.8

102.

9 [3

0.1]

10

2.9

[30.

1]

11.1

96.

9 [2

8.4]

9

3.3

[27.

4]

10.8

95.

0 [2

7.8]

8

8.7

[26.

0]

10.7

97.

6 [2

8.6]

9

7.6

[28.

6]

11.1

91.

9 [2

6.9]

9

1.9

[26.

9]

10.8

90.

1 [2

6.4]

9

0.1

[26.

4]

10.7

92.

3 [2

7.0]

9

2.3

[27.

0]

11.1

86.

9 [2

5.5]

8

6.9

[25.

5]

10.7

85.

2 [2

5.0]

8

5.2

[25.

0]

10.6

115°

F [4

6.1]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

118.

9 [3

4.8]

7

9.0

[23.

1]

11.9

111.

9 [3

2.8]

6

8.1

[20.

0]

11.5

109.

8 [3

2.2]

6

4.8

[19.

0]

11.4

109.

0 [3

1.9]

9

5.2

[27.

9]

11.8

102.

6 [3

0.1]

8

2.1

[24.

1]

11.4

100.

6 [2

9.5]

7

8.1

[22.

9]

11.3

98.

7 [2

8.9]

9

8.7

[28.

9]

11.7

92.

9 [2

7.2]

9

1.7

[26.

9]

11.4

91.

2 [2

6.7]

8

7.2

[25.

6]

11.3

93.

5 [2

7.4]

9

3.5

[27.

4]

11.7

88.

0 [2

5.8]

8

8.0

[25.

8]

11.3

86.

3 [2

5.3]

8

6.3

[25.

3]

11.2

88.

1 [2

5.8]

8

8.1

[25.

8]

11.6

83.

0 [2

4.3]

8

3.0

[24.

3]

11.3

81.

4 [2

3.8]

8

1.4

[23.

8]

11.2

120°

F [4

8.9]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

114.

5 [3

3.5]

7

7.0

[22.

6]

12.5

107.

8 [3

1.6]

6

6.4

[19.

5]

12.1

105.

7 [3

1.0]

6

3.1

[18.

5]

12.0

104.

6 [3

0.6]

9

3.2

[27.

3]

12.4

98.

5 [2

8.9]

8

0.4

[23.

6]

12.0

96.

6 [2

8.3]

7

6.5

[22.

4]

11.9

94.

3 [2

7.6]

9

4.3

[27.

6]

12.3

88.

8 [2

6.0]

8

8.8

[26.

0]

12.0

87.

1 [2

5.5]

8

5.6

[25.

1]

11.9

89.

0 [2

6.1]

8

9.0

[26.

1]

12.3

83.

8 [2

4.6]

8

3.8

[24.

6]

11.9

82.

2 [2

4.1]

8

2.2

[24.

1]

11.8

83.

7 [2

4.5]

8

3.7

[24.

5]

12.3

78.

8 [2

3.1]

7

8.8

[23.

1]

11.9

77.

3 [2

2.6]

7

7.3

[22.

6]

11.8

125°

F [5

1.7]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

109.

8 [3

2.2]

7

4.9

[21.

9]

13.1

103.

4 [3

0.3]

6

4.6

[18.

9]

12.8

101.

4 [2

9.7]

6

1.4

[18.

0]

12.6

99.

9 [2

9.3]

9

1.1

[26.

7]

13.1

94.

1 [2

7.6]

7

8.6

[23.

0]

12.7

92.

3 [2

7.0]

7

4.7

[21.

9]

12.6

89.

6 [2

6.3]

8

9.6

[26.

3]

13.0

84.

4 [2

4.7]

8

4.4

[24.

7]

12.6

82.

8 [2

4.3]

8

2.8

[24.

3]

12.5

84.

4 [2

4.7]

8

4.4

[24.

7]

13.0

79.

5 [2

3.3]

7

9.5

[23.

3]

12.6

77.

9 [2

2.8]

7

7.9

[22.

8]

12.5

79.

0 [2

3.2]

7

9.0

[23.

2]

12.9

74.

4 [2

1.8]

7

4.4

[21.

8]

12.6

73.

0 [2

1.4]

7

3.0

[21.

4]

12.4

Performance Data RACL

CO

OLI

NG

PE

RFO

RM

AN

CE

DAT

A—

RA

CL2

120+

RH

CLA

2120

NOTE

S:

➀W

hen

the

ente

ring

air d

ry b

ulb

is o

ther

than

80°

F [2

7°C]

, adj

ust t

he s

ensi

ble

capa

city

fro

m th

e ta

ble

by a

ddin

g [1

.10

x CF

M x

(1 –

DR)

x (d

bE –

80)

].

DR —

Depr

essi

on ra

tio

dbE

—En

terin

g ai

r dry

bul

b w

bE—

Ente

ring

air w

et b

ulb

Tota

l —

Tota

l cap

acity

x 1

000

BTUH

Se

ns —

Sens

ible

cap

acity

x 1

000

BTUH

Po

wer

—KW

inpu

t

[ ]

Des

igna

tes

Met

ric

Co

nver

sio

ns

Page 15: CLIMATEMASTER COMMERCIAL CONDENSER

ClimateMaster® 15

ENTE

RING

INDO

OR A

IR @

80°

F [2

6.7°

C] d

bE ➀

wbE

71°F

[21.

7°C]

67°F

[19.

4°C]

63°F

[17.

2°C]

61°F

[16.

1°C]

59°F

[15.

0°C]

CFM

[L/s

]60

00 [2

832]

5000

[236

0]40

00 [1

888]

6000

[283

2]50

00 [2

360]

4000

[188

8]60

00 [2

832]

5000

[236

0]40

00 [1

888]

6000

[283

2]50

00 [2

360]

4000

[188

8]60

00 [2

832]

5000

[236

0]40

00 [1

888]

DR ➀

0.07

0.02

-0.0

40.

070.

02-0

.04

0.07

0.02

-0.0

40.

070.

02-0

.04

0.07

0.02

-0.0

4

O

U

T

D

O

O

R D

R

Y B

U

L B T

E

M

P

E

R

A

T

U

R

E °F

[°C

]

75° F

[2

3.9]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

175.

3 [5

1.4]

11

3.6

[33.

3]

10.0

169.

2 [4

9.6]

10

3.9

[30.

4]

9.8

163.

0 [4

7.8]

9

4.2

[27.

6]

9.6

167.

1 [4

9.0]

13

4.3

[39.

3]

9.9

161.

2 [4

7.2]

12

2.8

[36.

0]

9.7

155.

3 [4

5.5]

11

1.3

[32.

6]

9.5

164.

5 [4

8.2]

14

9.8

[43.

9]

9.8

158.

7 [4

6.5]

13

7.0

[40.

1]

9.6

152.

9 [4

4.8]

12

4.2

[36.

4]

9.4

166.

1 [4

8.7]

15

6.4

[45.

8]

9.7

160.

3 [4

7.0]

14

3.1

[41.

9]

9.5

154.

5 [4

5.3]

12

9.7

[38.

0]

9.4

170.

2 [4

9.9]

16

3.0

[47.

8]

9.6

164.

3 [4

8.1]

14

9.0

[43.

7]

9.5

158.

3 [4

6.4]

13

5.1

[39.

6]

9.3

80° F

[2

6.7]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

172.

5 [5

0.6]

11

4.2

[33.

5]

10.5

166.

5 [4

8.8]

10

4.5

[30.

6]

10.3

160.

4 [4

7.0]

9

4.7

[27.

8]

10.1

164.

2 [4

8.1]

13

4.9

[39.

5]

10.3

158.

5 [4

6.4]

12

3.4

[36.

1]

10.2

152.

7 [4

4.7]

11

1.8

[32.

8]

10.0

161.

6 [4

7.4]

15

0.4

[44.

1]

10.2

156.

0 [4

5.7]

13

7.6

[40.

3]

10.0

150.

3 [4

4.0]

12

4.7

[36.

6]

9.9

163.

3 [4

7.8]

15

7.1

[46.

0]

10.2

157.

5 [4

6.2]

14

3.7

[42.

1]

10.0

151.

8 [4

4.5]

13

0.3

[38.

2]

9.8

167.

4 [4

9.1]

16

3.6

[47.

9]

10.1

161.

5 [4

7.3]

14

9.6

[43.

8]

9.9

155.

7 [4

5.6]

13

5.7

[39.

8]

9.8

85° F

[2

9.4]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

169.

3 [4

9.6]

11

3.9

[33.

4]

11.0

163.

4 [4

7.9]

10

4.2

[30.

5]

10.8

157.

4 [4

6.1]

9

4.5

[27.

7]

10.6

161.

0 [4

7.2]

13

4.6

[39.

4]

10.8

155.

4 [4

5.5]

12

3.1

[36.

1]

10.7

149.

7 [4

3.9]

11

1.6

[32.

7]

10.5

158.

4 [4

6.4]

15

0.1

[44.

0]

10.7

152.

9 [4

4.8]

13

7.3

[40.

2]

10.5

147.

3 [4

3.2]

12

4.5

[36.

5]

10.4

160.

1 [4

6.9]

15

6.8

[45.

9]

10.7

154.

5 [4

5.3]

14

3.4

[42.

0]

10.5

148.

8 [4

3.6]

13

0.0

[38.

1]

10.3

164.

2 [4

8.1]

16

3.3

[47.

8]

10.6

158.

4 [4

6.4]

14

9.3

[43.

8]

10.4

152.

7 [4

4.7]

13

5.4

[39.

7]

10.2

90° F

[3

2.2]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

165.

8 [4

8.6]

11

2.7

[33.

0]

11.5

159.

9 [4

6.9]

10

3.0

[30.

2]

11.3

154.

1 [4

5.2]

9

3.4

[27.

4]

11.1

157.

5 [4

6.1]

13

3.3

[39.

1]

11.4

151.

9 [4

4.5]

12

1.9

[35.

7]

11.2

146.

4 [4

2.9]

11

0.6

[32.

4]

11.0

154.

9 [4

5.4]

14

8.9

[43.

6]

11.3

149.

4 [4

3.8]

13

6.2

[39.

9]

11.1

144.

0 [4

2.2]

12

3.4

[36.

2]

10.9

156.

5 [4

5.9]

15

5.5

[45.

6]

11.2

151.

0 [4

4.3]

14

2.3

[41.

7]

11.0

145.

5 [4

2.6]

12

9.0

[37.

8]

10.8

160.

6 [4

7.1]

16

0.6

[47.

1]

11.2

155.

0 [4

5.4]

14

8.2

[43.

4]

11.0

149.

4 [4

3.8]

13

4.4

[39.

4]

10.8

95° F

[3

5]° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

161.

8 [4

7.4]

11

0.5

[32.

4]

12.1

156.

2 [4

5.8]

10

1.1

[29.

6]

11.9

150.

5 [4

4.1]

9

1.6

[26.

8]

11.7

153.

6 [4

5.0]

13

1.2

[38.

4]

12.0

148.

2 [4

3.4]

12

0.0

[35.

2]

11.8

142.

8 [4

1.8]

10

8.8

[31.

9]

11.6

151.

0 [4

4.2]

14

6.7

[43.

0]

11.9

145.

7 [4

2.7]

13

4.2

[39.

3]

11.7

140.

4 [4

1.1]

12

1.6

[35.

6]

11.5

152.

6 [4

4.7]

15

2.6

[44.

7]

11.8

147.

2 [4

3.1]

14

0.3

[41.

1]

11.6

141.

9 [4

1.6]

12

7.2

[37.

3]

11.4

156.

7 [4

5.9]

15

6.7

[45.

9]

11.8

151.

2 [4

4.3]

14

6.2

[42.

8]

11.6

145.

7 [4

2.7]

13

2.6

[38.

8]

11.3

100°

F [3

7.8]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

157.

6 [4

6.2]

10

7.4

[31.

5]

12.7

152.

0 [4

4.6]

9

8.2

[28.

8]

12.5

146.

5 [4

2.9]

8

9.1

[26.

1]

12.3

149.

3 [4

3.7]

12

8.1

[37.

5]

12.6

144.

0 [4

2.2]

11

7.1

[34.

3]

12.4

138.

8 [4

0.7]

10

6.2

[31.

1]

12.2

146.

7 [4

3.0]

14

3.6

[42.

1]

12.5

141.

6 [4

1.5]

13

1.3

[38.

5]

12.3

136.

4 [4

0.0]

11

9.1

[34.

9]

12.1

148.

3 [4

3.5]

14

8.3

[43.

5]

12.4

143.

1 [4

1.9]

13

7.4

[40.

3]

12.2

137.

9 [4

0.4]

12

4.6

[36.

5]

12.0

152.

5 [4

4.7]

15

2.5

[44.

7]

12.4

147.

1 [4

3.1]

14

3.4

[42.

0]

12.2

141.

8 [4

1.5]

13

0.0

[38.

1]

12.0

105°

F [4

0.6]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

152.

9 [4

4.8]

10

3.4

[30.

3]

13.4

147.

6 [4

3.2]

9

4.5

[27.

7]

13.2

142.

2 [4

1.7]

8

5.7

[25.

1]

12.9

144.

7 [4

2.4]

12

4.0

[36.

3]

13.3

139.

6 [4

0.9]

11

3.4

[33.

2]

13.1

134.

5 [3

9.4]

10

2.8

[30.

1]

12.8

142.

1 [4

1.6]

13

9.6

[40.

9]

13.2

137.

1 [4

0.2]

12

7.6

[37.

4]

12.9

132.

1 [3

8.7]

11

5.7

[33.

9]

12.7

143.

7 [4

2.1]

14

3.7

[42.

1]

13.1

138.

7 [4

0.6]

13

3.7

[39.

2]

12.9

133.

6 [3

9.2]

12

1.3

[35.

5]

12.7

147.

8 [4

3.3]

14

7.8

[43.

3]

13.1

142.

6 [4

1.8]

13

9.7

[40.

9]

12.8

137.

5 [4

0.3]

12

6.7

[37.

1]

12.6

110°

F [4

3.3]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

148.

0 [4

3.4]

9

8.4

[28.

8]

14.1

142.

8 [4

1.8]

9

0.0

[26.

4]

13.9

137.

6 [4

0.3]

8

1.6

[23.

9]

13.6

139.

7 [4

0.9]

11

9.1

[34.

9]

14.0

134.

8 [3

9.5]

10

8.9

[31.

9]

13.8

129.

9 [3

8.1]

9

8.7

[28.

9]

13.5

137.

1 [4

0.2]

13

4.6

[39.

4]

13.9

132.

3 [3

8.8]

12

3.1

[36.

1]

13.6

127.

5 [3

7.4]

11

1.6

[32.

7]

13.4

138.

7 [4

0.6]

13

8.7

[40.

6]

13.8

133.

8 [3

9.2]

12

9.2

[37.

9]

13.6

129.

0 [3

7.8]

11

7.1

[34.

3]

13.3

142.

8 [4

1.9]

14

2.8

[41.

9]

13.8

137.

8 [4

0.4]

13

5.2

[39.

6]

13.5

132.

8 [3

8.9]

12

2.5

[35.

9]

13.3

115°

F [4

6.1]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

142.

6 [4

1.8]

9

2.5

[27.

1]

14.9

137.

6 [4

0.3]

8

4.6

[24.

8]

14.6

132.

6 [3

8.9]

7

6.7

[22.

5]

14.3

134.

3 [3

9.4]

11

3.2

[33.

2]

14.7

129.

6 [3

8.0]

10

3.5

[30.

3]

14.5

124.

9 [3

6.6]

9

3.8

[27.

5]

14.2

131.

7 [3

8.6]

12

8.7

[37.

7]

14.6

127.

1 [3

7.3]

11

7.7

[34.

5]

14.4

122.

5 [3

5.9]

10

6.7

[31.

3]

14.1

133.

4 [3

9.1]

13

3.4

[39.

1]

14.6

128.

7 [3

7.7]

12

3.8

[36.

3]

14.3

124.

0 [3

6.3]

11

2.2

[32.

9]

14.1

137.

5 [4

0.3]

13

7.5

[40.

3]

14.5

132.

7 [3

8.9]

12

9.8

[38.

0]

14.3

127.

9 [3

7.5]

11

7.6

[34.

5]

14.0

120°

F [4

8.9]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

136.

9 [4

0.1]

8

5.7

[25.

1]

15.7

132.

1 [3

8.7]

7

8.3

[23.

0]

15.4

127.

3 [3

7.3]

7

1.0

[20.

8]

15.1

128.

6 [3

7.7]

10

6.3

[31.

2]

15.5

124.

1 [3

6.4]

9

7.3

[28.

5]

15.3

119.

6 [3

5.0]

8

8.2

[25.

8]

15.0

126.

0 [3

6.9]

12

1.9

[35.

7]

15.4

121.

6 [3

5.6]

11

1.5

[32.

7]

15.2

117.

2 [3

4.3]

10

1.1

[29.

6]

14.9

127.

7 [3

7.4]

12

7.7

[37.

4]

15.4

123.

2 [3

6.1]

11

7.6

[34.

4]

15.1

118.

7 [3

4.8]

10

6.6

[31.

2]

14.8

131.

8 [3

8.6]

13

1.8

[38.

6]

15.3

127.

2 [3

7.3]

12

3.5

[36.

2]

15.0

122.

6 [3

5.9]

11

2.0

[32.

8]

14.8

125°

F [5

1.7]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

130.

9 [3

8.3]

7

7.9

[22.

8]

16.5

126.

3 [3

7.0]

7

1.2

[20.

9]

16.2

121.

7 [3

5.7]

6

4.6

[18.

9]

15.9

122.

6 [3

5.9]

9

8.6

[28.

9]

16.4

118.

3 [3

4.7]

9

0.2

[26.

4]

16.1

114.

0 [3

3.4]

8

1.7

[24.

0]

15.8

120.

0 [3

5.2]

11

4.1

[33.

4]

16.2

115.

8 [3

3.9]

10

4.4

[30.

6]

16.0

111.

6 [3

2.7]

9

4.6

[27.

7]

15.7

121.

6 [3

5.6]

12

0.8

[35.

4]

16.2

117.

3 [3

4.4]

11

0.5

[32.

4]

15.9

113.

1 [3

3.1]

10

0.1

[29.

3]

15.6

125.

7 [3

6.8]

12

5.7

[36.

8]

16.1

121.

3 [3

5.6]

11

6.4

[34.

1]

15.9

116.

9 [3

4.3]

10

5.5

[30.

9]

15.6

Performance Data RACL

CO

OLI

NG

PE

RFO

RM

AN

CE

DAT

A—

RA

CL2

150+

RH

CLA

2150

NOTE

S:

➀W

hen

the

ente

ring

air d

ry b

ulb

is o

ther

than

80°

F [2

7°C]

, adj

ust t

he s

ensi

ble

capa

city

fro

m th

e ta

ble

by a

ddin

g [1

.10

x CF

M x

(1 –

DR)

x (d

bE –

80)

].

DR —

Depr

essi

on ra

tio

dbE

—En

terin

g ai

r dry

bul

b w

bE—

Ente

ring

air w

et b

ulb

Tota

l —

Tota

l cap

acity

x 1

000

BTUH

Se

ns —

Sens

ible

cap

acity

x 1

000

BTUH

Po

wer

—KW

inpu

t

[ ]

Des

igna

tes

Met

ric

Co

nver

sio

ns

Page 16: CLIMATEMASTER COMMERCIAL CONDENSER

16 ClimateMaster®

ENTE

RING

INDO

OR A

IR @

80°

F [2

6.7°

C] d

bE ➀

wbE

71°F

[21.

7°C]

67°F

[19.

4°C]

63°F

[17.

2°C]

61°F

[16.

1°C]

59°F

[15.

0°C]

CFM

[L/s

]86

40 [4

078]

7200

[339

8]57

60 [2

718]

8640

[407

8]72

00 [3

398]

5760

[271

8]86

40 [4

078]

7200

[339

8]57

60 [2

718]

8640

[407

8]72

00 [3

398]

5760

[271

8]86

40 [4

078]

7200

[339

8]57

60 [2

718]

DR ➀

0.11

0.08

0.04

0.11

0.08

0.04

0.11

0.08

0.04

0.11

0.08

0.04

0.11

0.08

0.04

O

U

T

D

O

O

R D

R

Y B

U

L B T

E

M

P

E

R

A

T

U

R

E °F

[°C

]

75° F

[2

3.9]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

329.

1 [9

6.4]

19

5.9

[57.

4]

238.

6

317.

5 [9

3.0]

17

9.2

[52.

5]

234.

5

306.

0 [8

9.7]

16

2.5

[47.

6]

230.

4

308.

1 [9

0.3]

22

7.9

[66.

8]

238.

3

297.

3 [8

7.1]

20

8.5

[61.

1]

234.

1

286.

5 [8

4.0]

18

9.0

[55.

4]

230.

0

289.

6 [8

4.9]

25

3.3

[74.

2]

237.

9

279.

4 [8

1.9]

23

1.6

[67.

9]

233.

8

269.

3 [7

8.9]

21

0.0

[61.

5]

229.

7

281.

7 [8

2.6]

26

2.3

[76.

9]

237.

7

271.

8 [7

9.7]

23

9.9

[70.

3]

233.

6

262.

0 [7

6.8]

21

7.5

[63.

7]

229.

5

275.

1 [8

0.6]

26

8.2

[78.

6]

237.

6

265.

5 [7

7.8]

24

5.3

[71.

9]

233.

4

255.

8 [7

5.0]

22

2.4

[65.

2]

229.

3

80° F

[2

6.7]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

314.

8 [9

2.3]

18

7.0

[54.

8]

239.

3

303.

8 [8

9.0]

17

1.0

[50.

1]

235.

2

292.

7 [8

5.8]

15

5.1

[45.

4]

231.

0

293.

9 [8

6.1]

21

9.0

[64.

2]

239.

0

283.

6 [8

3.1]

20

0.3

[58.

7]

234.

8

273.

3 [8

0.1]

18

1.6

[53.

2]

230.

7

275.

4 [8

0.7]

24

4.3

[71.

6]

238.

6

265.

7 [7

7.9]

22

3.5

[65.

5]

234.

5

256.

0 [7

5.0]

20

2.6

[59.

4]

230.

3

267.

5 [7

8.4]

25

3.4

[74.

3]

238.

4

258.

1 [7

5.6]

23

1.8

[67.

9]

234.

3

248.

7 [7

2.9]

21

0.1

[61.

6]

230.

2

260.

9 [7

6.4]

25

9.2

[76.

0]

238.

3

251.

7 [7

3.8]

23

7.1

[69.

5]

234.

1

242.

6 [7

1.1]

21

5.0

[63.

0]

230.

0

85° F

[2

9.4]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

301.

7 [8

8.4]

17

8.9

[52.

4]

240.

1

291.

1 [8

5.3]

16

3.6

[47.

9]

236.

0

280.

5 [8

2.2]

14

8.3

[43.

5]

231.

8

280.

7 [8

2.3]

21

0.9

[61.

8]

239.

8

270.

9 [7

9.4]

19

2.9

[56.

5]

235.

6

261.

0 [7

6.5]

17

4.9

[51.

3]

231.

5

262.

2 [7

6.8]

23

6.2

[69.

2]

239.

4

253.

0 [7

4.1]

21

6.1

[63.

3]

235.

3

243.

8 [7

1.4]

19

5.9

[57.

4]

231.

1

254.

3 [7

4.5]

24

5.3

[71.

9]

239.

2

245.

4 [7

1.9]

22

4.3

[65.

7]

235.

1

236.

5 [6

9.3]

20

3.4

[59.

6]

230.

9

247.

7 [7

2.6]

24

7.7

[72.

6]

239.

1

239.

0 [7

0.0]

22

9.7

[67.

3]

234.

9

230.

3 [6

7.5]

20

8.3

[61.

0]

230.

8

90° F

[3

2.2]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

289.

5 [8

4.8]

17

1.6

[50.

3]

241.

0

279.

4 [8

1.9]

15

6.9

[46.

0]

236.

9

269.

2 [7

8.9]

14

2.3

[41.

7]

232.

7

268.

6 [7

8.7]

20

3.6

[59.

7]

240.

7

259.

2 [7

5.9]

18

6.2

[54.

6]

236.

5

249.

8 [7

3.2]

16

8.9

[49.

5]

232.

3

250.

1 [7

3.3]

22

8.9

[67.

1]

240.

3

241.

3 [7

0.7]

20

9.4

[61.

4]

236.

2

232.

5 [6

8.1]

18

9.8

[55.

6]

232.

0

242.

2 [7

1.0]

23

8.0

[69.

7]

240.

1

233.

7 [6

8.5]

21

7.7

[63.

8]

236.

0

225.

2 [6

6.0]

19

7.4

[57.

8]

231.

8

235.

6 [6

9.0]

23

5.6

[69.

0]

240.

0

227.

3 [6

6.6]

22

3.0

[65.

4]

235.

8

219.

1 [6

4.2]

20

2.2

[59.

3]

231.

6

95° F

[3

5]° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

278.

5 [8

1.6]

16

5.1

[48.

4]

242.

1

268.

7 [7

8.7]

15

1.0

[44.

3]

237.

9

259.

0 [7

5.9]

13

6.9

[40.

1]

233.

7

257.

6 [7

5.5]

19

7.1

[57.

8]

241.

7

248.

5 [7

2.8]

18

0.3

[52.

8]

237.

5

239.

5 [7

0.2]

16

3.5

[47.

9]

233.

3

239.

0 [7

0.0]

22

2.5

[65.

2]

241.

3

230.

6 [6

7.6]

20

3.5

[59.

6]

237.

2

222.

3 [6

5.1]

18

4.5

[54.

1]

233.

0

231.

2 [6

7.7]

23

1.2

[67.

7]

241.

2

223.

0 [6

5.4]

21

1.7

[62.

1]

237.

0

214.

9 [6

3.0]

19

2.0

[56.

3]

232.

8

224.

5 [6

5.8]

22

4.5

[65.

8]

241.

0

216.

7 [6

3.5]

21

6.7

[63.

5]

236.

8

208.

8 [6

1.2]

19

6.8

[57.

7]

232.

6

100°

F [3

7.8]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

268.

5 [7

8.7]

15

9.5

[46.

7]

243.

2

259.

1 [7

5.9]

14

5.8

[42.

7]

239.

0

249.

7 [7

3.2]

13

2.2

[38.

7]

234.

7

247.

6 [7

2.5]

19

1.5

[56.

1]

242.

8

238.

9 [7

0.0]

17

5.1

[51.

3]

238.

6

230.

2 [6

7.5]

15

8.8

[46.

5]

234.

4

229.

0 [6

7.1]

21

6.8

[63.

5]

242.

5

221.

0 [6

4.8]

19

8.3

[58.

1]

238.

3

213.

0 [6

2.4]

17

9.8

[52.

7]

234.

1

221.

2 [6

4.8]

22

1.2

[64.

8]

242.

3

213.

4 [6

2.5]

20

6.6

[60.

5]

238.

1

205.

6 [6

0.3]

18

7.3

[54.

9]

233.

9

214.

5 [6

2.9]

21

4.5

[62.

9]

242.

1

207.

0 [6

0.7]

20

7.0

[60.

7]

237.

9

199.

5 [5

8.5]

19

2.2

[56.

3]

233.

7

105°

F [4

0.6]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

259.

6 [7

6.1]

15

4.6

[45.

3]

244.

4

250.

5 [7

3.4]

14

1.4

[41.

4]

240.

2

241.

4 [7

0.7]

12

8.2

[37.

6]

235.

9

238.

6 [6

9.9]

18

6.6

[54.

7]

244.

1

230.

3 [6

7.5]

17

0.7

[50.

0]

239.

8

221.

9 [6

5.0]

15

4.8

[45.

4]

235.

6

220.

1 [6

4.5]

21

2.0

[62.

1]

243.

7

212.

4 [6

2.2]

19

3.9

[56.

8]

239.

5

204.

7 [6

0.0]

17

5.8

[51.

5]

235.

2

212.

2 [6

2.2]

21

2.2

[62.

2]

243.

5

204.

8 [6

0.0]

20

2.1

[59.

2]

239.

3

197.

4 [5

7.8]

18

3.3

[53.

7]

235.

1

205.

6 [6

0.3]

20

5.6

[60.

3]

243.

3

198.

4 [5

8.1]

19

8.4

[58.

1]

239.

1

191.

2 [5

6.0]

18

8.1

[55.

1]

234.

9

110°

F [4

3.3]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

251.

7 [7

3.8]

15

0.6

[44.

1]

245.

8

242.

9 [7

1.2]

13

7.7

[40.

4]

241.

5

234.

1 [6

8.6]

12

4.9

[36.

6]

237.

2

230.

8 [6

7.6]

18

2.6

[53.

5]

245.

4

222.

7 [6

5.3]

16

7.0

[48.

9]

241.

1

214.

6 [6

2.9]

15

1.4

[44.

4]

236.

9

212.

3 [6

2.2]

20

7.9

[60.

9]

245.

0

204.

8 [6

0.0]

19

0.2

[55.

7]

240.

8

197.

4 [5

7.8]

17

2.4

[50.

5]

236.

5

204.

4 [5

9.9]

20

4.4

[59.

9]

244.

9

197.

2 [5

7.8]

19

7.2

[57.

8]

240.

6

190.

0 [5

5.7]

17

9.9

[52.

7]

236.

4

197.

8 [5

8.0]

19

7.8

[58.

0]

244.

7

190.

8 [5

5.9]

19

0.8

[55.

9]

240.

4

183.

9 [5

3.9]

18

3.9

[53.

9]

236.

2

115°

F [4

6.1]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

244.

9 [7

1.8]

14

7.4

[43.

2]

247.

2

236.

3 [6

9.3]

13

4.8

[39.

5]

242.

9

227.

7 [6

6.7]

12

2.2

[35.

8]

238.

6

224.

0 [6

5.6]

17

9.4

[52.

6]

246.

8

216.

1 [6

3.3]

16

4.1

[48.

1]

242.

6

208.

3 [6

1.0]

14

8.8

[43.

6]

238.

3

205.

5 [6

0.2]

20

4.7

[60.

0]

246.

5

198.

3 [5

8.1]

18

7.2

[54.

9]

242.

2

191.

0 [5

6.0]

16

9.8

[49.

7]

237.

9

197.

6 [5

7.9]

19

7.6

[57.

9]

246.

3

190.

7 [5

5.9]

19

0.7

[55.

9]

242.

0

183.

7 [5

3.8]

17

7.3

[51.

9]

237.

8

191.

0 [5

6.0]

19

1.0

[56.

0]

246.

1

184.

3 [5

4.0]

18

4.3

[54.

0]

241.

9

177.

6 [5

2.0]

17

7.6

[52.

0]

237.

6

120°

F [4

8.9]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

239.

2 [7

0.1]

14

5.0

[42.

5]

248.

8

230.

8 [6

7.6]

13

2.6

[38.

9]

244.

4

222.

4 [6

5.2]

12

0.2

[35.

2]

240.

1

218.

2 [6

4.0]

17

7.0

[51.

9]

248.

4

210.

6 [6

1.7]

16

1.9

[47.

4]

244.

1

202.

9 [5

9.5]

14

6.8

[43.

0]

239.

8

199.

7 [5

8.5]

19

9.7

[58.

5]

248.

0

192.

7 [5

6.5]

18

5.0

[54.

2]

243.

7

185.

7 [5

4.4]

16

7.8

[49.

2]

239.

4

191.

8 [5

6.2]

19

1.8

[56.

2]

247.

9

185.

1 [5

4.2]

18

5.1

[54.

2]

243.

6

178.

4 [5

2.3]

17

5.3

[51.

4]

239.

3

185.

2 [5

4.3]

18

5.2

[54.

3]

247.

7

178.

7 [5

2.4]

17

8.7

[52.

4]

243.

4

172.

2 [5

0.5]

17

2.2

[50.

5]

239.

1

125°

F [5

1.7]

° C

Tota

l BTU

H [k

W]

Sens

BTU

H [k

W]

Pow

er

234.

5 [6

8.7]

14

3.4

[42.

0]

250.

4

226.

3 [6

6.3]

13

1.1

[38.

4]

246.

1

218.

1 [6

3.9]

11

8.9

[34.

8]

241.

7

213.

6 [6

2.6]

17

5.4

[51.

4]

250.

1

206.

1 [6

0.4]

16

0.4

[47.

0]

245.

7

198.

6 [5

8.2]

14

5.5

[42.

6]

241.

4

195.

1 [5

7.2]

19

5.1

[57.

2]

249.

7

188.

2 [5

5.2]

18

3.6

[53.

8]

245.

4

181.

4 [5

3.1]

16

6.5

[48.

8]

241.

0

187.

2 [5

4.9]

18

7.2

[54.

9]

249.

5

180.

6 [5

2.9]

18

0.6

[52.

9]

245.

2

174.

0 [5

1.0]

17

4.0

[51.

0]

240.

9

180.

6 [5

2.9]

18

0.6

[52.

9]

249.

4

174.

2 [5

1.1]

17

4.2

[51.

1]

245.

0

167.

9 [4

9.2]

16

7.9

[49.

2]

240.

7

Performance Data RACL

CO

OLI

NG

PE

RFO

RM

AN

CE

DAT

A—

RA

CL2

240+

RH

CLA

2240

NOTE

S:

➀W

hen

the

ente

ring

air d

ry b

ulb

is o

ther

than

80°

F [2

7°C]

, adj

ust t

he s

ensi

ble

capa

city

fro

m th

e ta

ble

by a

ddin

g [1

.10

x CF

M x

(1 –

DR)

x (d

bE –

80)

].

DR —

Depr

essi

on ra

tio

dbE

—En

terin

g ai

r dry

bul

b w

bE—

Ente

ring

air w

et b

ulb

Tota

l —

Tota

l cap

acity

x 1

000

BTUH

Se

ns —

Sens

ible

cap

acity

x 1

000

BTUH

Po

wer

—KW

inpu

t

[ ]

Des

igna

tes

Met

ric

Co

nver

sio

ns

Page 17: CLIMATEMASTER COMMERCIAL CONDENSER

ClimateMaster® 17

General Installation RACL

GENERAL INSTALLATION The Remote Condensing unit must be installed outdoors. It should be located as near as possible to the indoor section to keep connecting refrigerant tubing lengths to a minimum. The unit must be installed to allow a free air flow to the outdoor coils.

If several units are installed adjacent to each other, care must be taken to avoid recirculation of air from one remote condenser to another. In all installations, adequate space must be provided for installation and servicing.

The outdoor unit must not be connected to any duct work. Do not locate unit under a roof drip; if necessary, install gutters, etc., to prevent water run-off from hitting the unit. To prevent air recir-culation, it is recommended that the unit not be installed under an overhang, but if necessary allow a minimum of 60 inches [1524 mm] above the unit for air discharge.

[ ] Designates Metric Conversions

SLAB INSTALLATION Remote Condensing units should be set on a solid level founda-tion. When installed at ground level, the unit should be placed on a 6 inch [152.4 mm] cement slab. If the pad is formed at the installa-tion site, do not pour the pad tight against the structure, otherwise vibration will be transmitted from the unit through the pad.

ROOFTOP INSTALLATION If rooftop installation is required, make certain that the building construction is adequate for the weight of the unit. (Refer to physical data chart.) Before placing the unit on the roof, make certain that the nylon rigging slings are of sufficient length to maintain equilibrium of the unit when lifting. Under no circum-stances should the unit be lifted by only one corner for rooftop installation.

Page 18: CLIMATEMASTER COMMERCIAL CONDENSER

18 ClimateMaster®

EQUIVALENT LENGTH (FT.) [m] OF STRAIGHT TYPE “L” TUBINGFOR NON-FERROUS VALVES AND FITTINGS (BRAZED)

TUBE SIZEINCHES [mm]

O.D.

ANGLEVALVE

SHORTRADIUS

ELL

LONGRADIUS

ELL

TEELINE

FLOW1/2 [12.7] 24   [7.32] 4.7 [1.43] 3.2 [0.98] 1.7 [0.52]5/8 [15.88] 25   [7.62] 5.7 [1.74] 3.9 [1.19] 2.3 [0.70]3/4 [19.05] 25   [7.62] 6.5 [1.98] 4.5 [1.37] 2.9 [0.88]7/8 [22.23] 28   [8.53] 7.8 [2.38] 5.3 [1.62] 3.7 [1.13]

11/8 [28.58] 29   [8.84] 2.7 [0.82] 1.9 [0.58] 5.2 [1.59]

13/8 [34.93] 33 [10.06] 3.2 [0.98] 2.2 [0.67] 6.9 [2.10]

Piping Recommendation RACL

TYPICAL REFRIGERANT PIPING RECOMMENDATIONS General Notes: 1. Vertical risers not to exceed 60 feet [18.29 m]. 2. Locate the remote condensing unit and indoor air handler as close together as possible to minimize piping runs. 3. Remote condensing units are shipped with a nitrogen holding charge. Evacuate remote condensing unit before charging with refrigerant. 4. Runs between remote condensing and indoor air handler are not to exceed 90' [27.43 m] linear length.

LIQUID LINE PRESSURE DROP PER 100 FEET [30.48 m] EQUIVALENT LENGTH

(TYPE L COPPER TUBING)

VAPOR LINE SYSTEM CAPACITY LOSS IN PERCENT PER 100 FEET [30.48 m] EQUIVALENT

LENGTH (TYPE L COPPER TUBING)

NOTES: 1) The pressure drop due to vertical lift (.5 PSIG per foot of lift)

[22.62 kPa per meter] must be added to the pressure drop derived from this curve.

2) Size liquid line for no more than 10°F [–12.2°C] loss (approxi-mately 50 PSIG [344.8 kPa] total pressure drop).

3) Do not oversize liquid line. Oversized liquid lines add signifi-cantly to the amount of refrigerant required to charge the system.

WARNING Do not use oxygen to purge lines or pressure system for leak test. Oxygen reacts violently with oil, which can cause an explo-sion resulting in severe personal injury or death.

COIL ABOVE CONDENSING UNIT

COIL BELOW CONDENSING UNIT

[ ] Designates Metric Conversions

NOTES: 1) The minimum velocity line (1500 FPM) [7.5 m/s] is

recommended. 2) With the outdoor unit located below the indoor air

handler, all vertical vapor lines must not exceed 11/8" [28.58 mm] O.D.

3) For suction pressure drop (PSIG) [6.9 kPa], multiply percent (%) loss by 1.18.

4) Size vapor lines for no more than a 5 PSIG [34.5 kPa] pressure drop (2.54% capacity loss) which corre-sponds to approximately 2°F [–16.7°C] loss.

5) All vertical vapor lines, 3 feet [.91 m] or more in length, must have a short radius oil trap at the bottom of the riser.

6) All vertical vapor lines, 30 feet [9.14 m] or more in length, must have short radius oil traps every 15 to 20 feet [4.57 to 6.10 m] of run.

Page 19: CLIMATEMASTER COMMERCIAL CONDENSER

ClimateMaster® 19

Piping Recommendation RACL

TUBE SIZEO.D. (IN.) [mm]

LIQUID(OZ.) [g]

VAPOR(OZ.) [g]

1/2  [12.7] 1.06 [30.0] .04   [1.13]5/8 [15.88] 1.65 [46.7] .07  [1.98]

7/8 [22.23] 3.28 [92.9] .13  [3.68]11/8 [28.58] .22  [6.23]13/8 [34.93] .34  [9.63]15/8 [41.28] .48 [13.60]21/8 [53.98] .84 [23.81]

3/4 [19.05] 2.46 [69.7] .10  [2.83]

GENERAL INSTALLATION The condensing unit should be installed outdoors. It should be located as near as possible to the evaporator section to keep connecting refrigerant tubing lengths to a minimum. The unit must be installed to allow a free air flow to the condenser coils.

If several units are installed adjacent to each other, care must be taken to avoid recirculation of air from one condenser to another. In all installations, adequate space must be provided for installation and servicing.

The unit must not be connected to any duct work. Do not locate unit under a roof drip; if necessary, install gutters, etc., to prevent water run-off from hitting the unit. To prevent air recir-culation, it is recommended that the unit not be instal led under an overhang, but if necessary allow a minimum of 60 inches [1524 mm] above the unit for air discharge.

ROOFTOP INSTALLATION If rooftop installation is required, make certain that the building construction is adequate for the weight of the unit. (Refer to physical data chart.) Before placing the unit on the roof, make certain that the nylon rigging slings are of sufficient length to maintain equilibrium of the unit when lifting. Under no circum-stances should the unit be lifted by only one corner for rooftop installation.

[ ] Designates Metric Conversions

TYPICAL REFRIGERANT PIPING RECOMMENDATIONS (con’t.)

REQUIRED OZS. R-410A CHARGE PER FT. [m] OF TUBING

CLEARANCES

36" min. [914 mm]

Condensing Unit Condensing Unit24" min. 24" min.[610mm] [610mm]

Control Box End Control Box End

36" min. [914 mm]

Quantities based on 110°F liquid and 45°F vapor.

Page 20: CLIMATEMASTER COMMERCIAL CONDENSER

20 ClimateMaster®

Sequence of Operation RACL

SEQUENCE OF OPERATION1. When the room thermostat is set on “Cool”, “Fan Auto”, and

the temperature is higher than the thermostat setting, the ther-mostat “Y1” circuit closes and energizes the number one compressor contactor (CC1) through the closed cooling relay (R) contacts. Power to the crankcase heater (CCH1) will be de-energized by the auxiliary contacts (AUX-1).

2. Simultaneously, the “G” circuit provides power to the indoor blower motor circuit and starts indoor air circulation through the evaporator coil.

3. When the discharge pressure increases to 450 psig, the con-tacts on the low ambient control (LAC) (if installed) will allow supply power to start the outdoor fan motors (ODF) which begin to pull air through the condenser coils. The system is now in first stage cooling, operating at near fifty percent of full load capacity.

4. If the temperature at the thermostat continues to increase, the thermostat “Y2” circuit closes and after a full 30 second delay, power passes through the time delay control (TDC) and ener-gizes the number two compressor contactor (CC2) through the second set of closed cooling relay (R) contacts. Power to the crankcase heater (CCH2) will be de-energized by the aux-iliary contacts (AUX-2).

5. The system will continue cooling at maximum capacity, as long as the room thermostat is demanding full load and all safety device contacts are closed. The low ambient control (LAC) (if installed) will open and close, allowing the outdoor fans to maintain discharge pressure between 250 and 450 psig.

6. As the temperature at the thermostat drops enough to satisfy “Y2”, the circuit will open and de-energize the compressor contactor (CC2), stopping compressor operation and closing the auxiliary contacts (AUX-2), which energizes the crankcase heater (CCH2).

7. When continued cooling satisfies the “Y1” circuit, it will open and de-energize the compressor contactor (CC1), stopping compressor operation and closing the auxiliary contacts (AUX-1), which energizes the crankcase heater (CCH1).

8. The thermostat “G” circuit will stop blower operation.

Page 21: CLIMATEMASTER COMMERCIAL CONDENSER

ClimateMaster® 21

Limited Warranty RACL

GENERAL TERMS OF LIMITED WARRANTY*ClimateMaster will furnish a replacement for any part of this product which fails in normal use and service within the applicable periods stated, in accordance with the terms of the limited warranty.

Compressor ........................................................Five (5) Years Any Other Part ................................................One (1) Year *For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy.

Page 22: CLIMATEMASTER COMMERCIAL CONDENSER

Notes RACL

22 ClimateMaster®

Page 23: CLIMATEMASTER COMMERCIAL CONDENSER

Notes RACL

ClimateMaster® 23

Page 24: CLIMATEMASTER COMMERCIAL CONDENSER

Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.

“In keeping with its policy of continuous progress and product improvement, the right is reserved to make changes without notice.”

PRINTED IN U.S.A. 4-21 QG Part No. : LC1093

www.ClimateMaster.com


Recommended