CONSTRUCTION TECHNOLOGY V QSM602
DR.LILAWATI AB WAHAB 1
TEMPORARY WORKS: COFFERDAMS & CAISSONS
Cofferdams usually refers to structures in water that are constructed on site, often from
standard parts. Identical structures on land are not usually called cofferdams and the name
seems to be falling out of use.
Caissons usually refers to structures which are constructed offsite and then brought to site
in one piece or in a series of independent modules.
What is cofferdam?
i. Temporary structure designed to keep water and/or soil out of the excavation in which a
bridge pier or other structure is built.
ii. The word "cofferdam" comes from "coffer" meaning box, in other words a dam in the
shape of a box.
iii. The word "cofferdam" comes from "coffer" meaning box, in other words a dam in the
shape of a box.
Function:
When construction must take place below the water level, a cofferdam is built to give
workers a dry work environment.
A cofferdam usually consists of sheets of steel driven into the ground to create a walled
chamber.
The cofferdam is then pumped dry to expose the riverbed.
Soil can be excavated to bedrock, or piles can be driven to create the pier foundation.
The cofferdam is removed after the foundation and pier are constructed.
Figure 1: Cofferdam
CONSTRUCTION TECHNOLOGY V QSM602
DR.LILAWATI AB WAHAB 2
Factors to be considered in selecting the type of cofferdam
i. Location on shore/off shore/on land/in water
ii. Depth and size of working area required inside the cofferdam.
iii. Accessibility of site.
iv. Nature of the permanent works to be built.
v. Amount of water and earth to be excluded.
vi. Soil conditions.
vii. Water conditions.
viii. Availability of materials and plants.
ix. Possible effect of cofferdams on adjacent structures.
x. Cost.
Cofferdams Construction Sequence
For a typical cofferdam, such as for a bridge pier, the construction procedure follow the listed
pattern :
1. Pre-dredge to remove soil or soft sediments and level the area of the cofferdam (Figure
a).
2. Drive temporary support piles (Figure b).
3. Temporarily erect bracing frame on the support piles (Figure b).
CONSTRUCTION TECHNOLOGY V QSM602
DR.LILAWATI AB WAHAB 3
4. Set steel sheet piles, starting at all four corners and meeting at the center of each side
(Figure c).
5. Drive sheet piles to grade (Figure c).
6. Block between bracing frame and sheets, and provide ties for sheet piles at the top as
necessary (Figure c).
7. Excavate inside the grade or slightly below grade, while leaving the cofferdam full of
water (Figure a).
CONSTRUCTION TECHNOLOGY V QSM602
DR.LILAWATI AB WAHAB 4
8. Check blocking between bracing and sheets (Figure a).
9. Dewater (Figure a).
10. Construct new structure (Figure a and b).
CONSTRUCTION TECHNOLOGY V QSM602
DR.LILAWATI AB WAHAB 5
11. Flood cofferdam; pull sheets; remove bracing; backfill (Figure c)
Types of cofferdam
Cofferdam can be categorised as Gravity Cofferdam, Sheeted Cofferdam and Soil
Stabilisation.
However, the basic types of cofferdam includes:
i. Earth-Type Cofferdam
ii. Crib Cofferdam
iii. Braced Cofferdam
iv. Cellular Cofferdam
v. Double-Walled Cofferdam
i. Earth-Type Cofferdam
Simplest type of Cofferdam.
Formed by banks of soil or rock.
Side slope depends on size and shape of stone.
Consists of an earth bank with a clay core or vertical sheet piling enclosing the
excavation.
Suitable for large area.
Used for low-level waters with low velocity.
Easily scoured by water rising over the top, unless using the rock fill type.
The top of the dam should be at least 2 feet above the water surface and the top width
not less than 3 feet.
Problems occur in removing the earth & rock fill.
CONSTRUCTION TECHNOLOGY V QSM602
DR.LILAWATI AB WAHAB 6
Figure 2: Earth-Type Cofferdam
ii. Crib Cofferdam
Also known as Gravity Dam.
Formed by framework of heavy timber or precast concrete units, which are laced
together in a criss-cross pattern to form pockets.
The crib is constructed on land and floated into place.
Units are secured by bolts and pockets are filled with rock or rubble for stability.
The crib side that faces the water can be made water tight by driving steel sheet piling
along it.
The crib can be removed and use repeatedly.
Used in rapid currents or on rocky river beds.
Figure 3: Crib Cofferdam
CONSTRUCTION TECHNOLOGY V QSM602
DR.LILAWATI AB WAHAB 7
iii. Braced Cofferdam
Also known as Single-Skin Cofferdam.
Formed from a single wall of sheet piling.
The piles are driven into the ground to form a box around the excavation site.
The "box" is then braced on the inside.
Interior is dewatered.
Primarily used for bridge piers in shallow water (30 - 35 ft depth).
Figure 4: Braced Cofferdam
Figure 5: Braced Cofferdam
CONSTRUCTION TECHNOLOGY V QSM602
DR.LILAWATI AB WAHAB 8
Figure 6: Braced Cofferdam
iv. Cellular Cofferdam
Two main types are circular and segmental.
The cofferdams are made off contiguous bored piles or diaphragm walling.
Can be used on a temporary or permanent basis, but should be designed to integrate
into permanent structures.
Forces are resisted by the mass of the cofferdam.
Are entirely self-supporting and do not require any other form of support (struts, braces
and tie-rods).
Figure 7: Cellular Cofferdam
CONSTRUCTION TECHNOLOGY V QSM602
DR.LILAWATI AB WAHAB 9
v. Double-Walled Cofferdam
Consists of two-parallel rows of steel sheet piles driven into the ground.
Tied together with anchors, then filled with soil to give stability.
Three principle types:
i. Box: Consists of straight flush walls
ii. Semicircular cells connected by diaphragms
iii. Circular cells connected with tie-rods or diaphragms
Figure 8: Double-Walled Cofferdam
Figure 9: Double-Walled Cofferdam (box type)
CONSTRUCTION TECHNOLOGY V QSM602
DR.LILAWATI AB WAHAB 10
Figure 10: Double-Walled Cofferdam (Semicircular cell)
Figure 11: Detail Double-Walled Cofferdam (Semicircular cell)
Design Consideration:
Scouring or undermining by rapidly flowing water.
Stability against overturning or tilting.
Upward forces on outside edge due to tilting.
Stability against vertical shear.
Effects of forces resulting from ice, wave, water, active and passive earth pressure.
CONSTRUCTION TECHNOLOGY V QSM602
DR.LILAWATI AB WAHAB 11
Safety Requirement:
In cofferdam construction, safety is a paramount concern, since workers will be exposed
to the hazard of flooding and collapse.
Safety requires: good design; proper construction; verification that the structure is being
constructed as planned; monitoring the behavior of the cofferdam and surrounding area;
provision of adequate access; light and ventilation; and attention to safe practices on the
part of all workers and supervisors.
Function:
In engineering, a caisson is a retaining, watertight structure used, for example, to work
on the foundations of a bridge pier, for the construction of a concrete dam, or for the
repair of ships.
A watertight, dry chamber in which people can work underwater.
A chamber, usually of steel but sometimes of wood or reinforced concrete, used in the
construction of foundations or piers in or near a body of water.
A caisson is a large cylinder or box chamber that is sunk into the riverbed.
The caisson will be brought down through soft mud until a suitable foundation material is
encountered.
While bedrock is preferred, a stable, hard mud is sometimes used when bedrock is too
deep.
The excavation and foundation work takes place within the submerged caisson.
Some caissons are removed after construction, while others are left in place, filled with
concrete, and used as part of a permanent foundation.
Type of caissons
The basic types of caisson includes:
i. Box Caisson
ii. Open Caisson
iii. Compressed-air Caisson (Pneumatic Caissons)
iv. Monolith Caisson
i. Box Caisson
Box caissons are pre-fab concrete boxes with sides and bottom that are set down on a
pre-prepared base.
Once in place they will be filled with concrete to become part of the permanent works, for
example the foundation for a bridge pier.
CONSTRUCTION TECHNOLOGY V QSM602
DR.LILAWATI AB WAHAB 12
The box caisson is fabricated at a plant and then towed a float and submerged on a
preliminarily prepared seabed owing to being flooded with water.
After the box caisson having been installed in place, its double sides are to be filled with
concrete to provide adequate strength, and the intermediate space is to be filled with
sand to provide adequate stability.
Figure 12: Box caisson
a) Box caisson floated into place with ballast as required.
(b) Caisson filled with appropriate material water may be pumped out first.
Figure 13 : Typical Box caisson
CONSTRUCTION TECHNOLOGY V QSM602
DR.LILAWATI AB WAHAB 13
Figure 14: Box caisson
ii. Open Caisson
Similar to box caissons except that they do not have a bottom face.
They are suitable for use in soft clays (e.g. in some river-beds) but not for where there
may be large obstructions in the ground.
The open caisson is a cylinder or box, open at the top and bottom, of size and shape to
suit the projected foundation and with a cutting edge around the bottom.
It is sunk by its own weight and by excavation, then filled with concrete.
Figure 15: Open caisson
CONSTRUCTION TECHNOLOGY V QSM602
DR.LILAWATI AB WAHAB 14
Open caissons permit excavation or other work to be carried out inside the caisson.
The caisson will sink down into the soil as excavation proceeds.
Sections can be added on top to increase height.
Water can be pumped out to permit dry work.
Figure 16: Open caisson
Suitable for installation in soft subsoil where excavation can be carried out by
conventional grabs, enabling the caisson to sink under its own weight as the
excavation proceeds.
This type of caissons can be completely or partially pre formed; section can be added
or cast on as the structure sinks to the required depth.
When the desired depth has been reached a concrete plug in the form of slab is
placed in the bottom by tremie pipe to prevent further ingress of water.
CONSTRUCTION TECHNOLOGY V QSM602
DR.LILAWATI AB WAHAB 15
Figure 17: Open caisson
Could also be installed in land if the subsoil conditions are suitable.
The shoe or cutting edge is formed so that it is wider than the wall above to create an
annular space some 75 to 100mm wide into which a bentonite slurry can be pumped to
act as lubricant and thus reduce the skin friction to a minimum.
The excavation operation is usually carried out simultaneously with the construction of
the caisson walls above ground level.
Figure 18: Open caisson
CONSTRUCTION TECHNOLOGY V QSM602
DR.LILAWATI AB WAHAB 16
iii. Compressed-air Caisson (Pneumatic Caissons)
Similar to open caissons except that there is an airtight working chamber some 3000m
high at the cutting edge.
They are used where difficult subsoils exist and where hand excavation in dry working
conditions is necessary.
The working chamber must be pressurised sufficiently to control the inflow of water
and/or soil and the same time provide safe working conditions for the operatives
When the required depth has been reached the floor of the working chamber can be
sealed over with a 600mm thick layers of concrete until only a small space
remains,which is pressure-grouted to finally seal the working chamber.
The access shafts are finally sealed with concrete some three to four days after sealing
off the working chamber.
Figure 19: Compressed-air Caisson (Pneumatic Caissons)
CONSTRUCTION TECHNOLOGY V QSM602
DR.LILAWATI AB WAHAB 17
Figure 20: Compressed-air Caisson
Figure 21 :Compress air cassion
iv. Monolith Caisson
Monoliths are as their name suggests larger than the other types but are similar to open
caissons.
They are often found in quay walls where resistance to impact from ships is required.