+ All Categories
Home > Documents > Commercial Heating Domestic Heating - Plinth...

Commercial Heating Domestic Heating - Plinth...

Date post: 25-Jul-2018
Category:
Upload: lyxuyen
View: 218 times
Download: 0 times
Share this document with a friend
48
#ThinkSmiths FREE 5 YEARS parts & labour on all products Manufactured in the UK GUARANTEE Commercial Heating Domestic Heating t w e n t y f t h a n n i ve r s a r y t w e n t y f t h a nn i v e r s a r y 25 1991-2016
Transcript
Page 1: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

#ThinkSmiths

FREE5 YEARSparts & labour on all productsManufactured in the UK

GUARANTEE

Commercial Heating • Domestic Heating

twen

ty

�fth anniversary

twenty �fth anniv

ersa

ry251991-2016

Page 2: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

Contents

Solutions for domestic & commercial applications p 4-5

Summary of product range - Commercial applications p 6-7

2 www.SmithsEP.co.uk

2. Domestic fan convectors p 32-37

3. Flame-effect fan convectors p 38-40

4. Natural convectors (perimeter heating) p 41

1. Commercial fan convectors p 8-29

5. Plinth Heaters - hydronic p 42-44

Glossary p 46

Summary of product range - Domestic applications p 30-31

6. Plinth Heaters - electric p 45

Co

nte

nts

Page 3: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

If you require energy efficiencyand versatility in your heating,the Smith’s range of fanconvectors is the ideal solution.

3 www.SmithsEP.co.uk

Intr

od

uct

ion

Why choose Smith’s?

For over twenty-five years, Smith’s EP UK has been manufacturing andproviding an extensive range of commercial and domestic heating and watersolutions from our head office in the UK. Part of the global family-ownedUS-based business, the Swan Group, Smith’s works closely with architects,consultants, heating contractors and installers to deliver high quality fanconvectors with industry-leading warranties on time, with an aftercare andtechnical support service that is second to none.

We take an active, innovative approach to new product development andcreating bespoke heating products to fulfil the creative requirements of acompetitive and demanding customer base that spans the UK, Northern Europeand the US. We believe it’s essential to be flexible in our partnerships, whileremaining uncompromising on the high quality and care that goes into everyproduct in our range. Smith’s is an outward-looking, growing business and weare forging relationships with like-minded manufacturers across Europe toensure that we can provide additional new and essential heating or waterproducts in areas where we do not specialise and where our partners excel.

Our latest brochure showcases our principal commercial and domestic products,detailing the range of fan convectors that we provide. At the same time, wehave the ability and the will to work alongside clients at any point in theconstruction process, and collaborate to develop specific solutions for any andevery need. We take great pride and go to great lengths to leave our customersnot only satisfied but coming back again and again for heating solutions thatare perfect for your project, each and every time.

Gary Haynes MBA, B.Eng.(Hons)Managing Director

#ThinkSmiths

Page 4: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

Solutions for domestic & commercial applications

Standard heating systems

4

How fan convectors work

Smith’s fan and flame-effect fan convectors work efficiently andeffectively with all types of wet central heating systems, includinggas, oil, electric, biomass or LPG boilers. They also require anelectrical connection to run the fan. Hot water from the centralheating system passes through the heat exchanger, transferring itsheat to the aluminium fins. Cooler air is drawn in by the fan andheated as it passes over the heat exchanger, before being expelledgently back into the room. This gives a more even temperaturespread and heats rooms in much less time than a traditional panelradiator. Each Smith’s fan convector includes a low temperaturecut-out system, preventing the product from operating until thesystem water temperature reaches a pre-set level. Electric versionsconnect to a standard electrical system via a fused spur.

Fan convectors use either AC or EC motor technology to drive thefan. AC motors typically provides the end user with a number offixed speeds whilst EC technology offers infinite control over thefan speed and heat output.

At home with Smith’s fan convectors

For a trained heating engineer, installing our fan convectors issimple because they use the same pipe work, fitting proceduresand heat loss calculations as radiators. We also provide installationguides for all our products via our website. With the heat outputswitch left on either normal or boost position, they will come onand off automatically with the central heating system. Each modelincludes a low temperature cut-out, which prevents the productoperating until the water temperature reaches a pre-settemperature. They can be used alone or paired with radiators andcan be sited almost anywhere to suit the size and style of thebuilding. Place them low on walls, above doorways or high up onother walls for safety or space considerations. Our renownedSpace Saver is designed to be sited in a plinth under a kitchenbase unit to create more storage space, worktop surface area orroom for additional white goods.

For those concerned about running costs, fan convectors use avery small amount of electricity to run the fan and/or bulb (flame-effect fan convectors only). Based on an annual usage of 1300hours with electricity charged at 15p per kWh, we calculateelectricity costs to be less than £5 per year for a fan convector andless than £10 per year for flame-effect fan convectors.

Natural Convectors(Perimeter Heating)Requiring connection to a wet central heating system, hot waterpasses through the heat exchanger, transferring its heat to thealuminium fins. The natural movement of air gently circulates overthe heat exchanger, is warmed and evenly distributed around theroom.

A typical central heating system combining condensingboiler, radiator, two EcoPowerad® fan convectors and aSpace Saver plinth heater.

www.SmithsEP.co.uk

Solu

tions

for c

omm

erci

al a

nd d

omes

tic a

pplic

atio

ns

Page 5: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

Low temperature heating systems

5

Working with heat pumps

Renewable technology grows apace, with ground and air sourceheat pumps beginning to become a viable alternative to boilers asthe principal heat generator in homes around the UK.

Inherent in the heat pump’s design is that the smaller thetemperature difference between the heat source pump (air orground) and the heat sink/emitter (under-floor heating, fanconvector, radiator), the higher the energy efficiency of that heatpump. This higher efficiency means lower fuel bills and greatercarbon savings for that home.

Fan convectors can work very effectively at system temperatures aslow as 40°C. This allows your chosen heat pump to work close toits maximum levels of efficiency, which means it will reduce theuser’s energy costs and energy consumption in the way that it wasintended. By contrast, a standard radiator is designed to beefficient at higher temperatures, 45°C and above, whichautomatically reduces the heat pump’s efficiency by more than10%. In addition the size of the radiator has to be increasedsignificantly to cope with the lower system temperatures.

SAP* calculation comparison

An example SAP calculation shows that using a combination of anair source heat pump with a fan convector in a new build orexisting property, should show a reduction of at least 12% inrunning costs (and carbon usage) when compared with a radiatorand air source heat pump, and that using a fan convector in thisway achieves close to the efficiencies obtained by installing under-floor heating.

*The Standard Assessment Procedure (SAP) is the UK Government'srecommended method system for measuring the energy rating ofresidential dwellings.

Comparable fan convector v radiator on a low temperature system

Height Width Depth Weight

Fan convector 400mm 1210mm 95mm 14kg

Radiator 600mm 1800mm 180mm 63kg

www.SmithsEP.co.uk

Solu

tions

for c

omm

erci

al a

nd d

omes

tic a

pplic

atio

ns

Page 6: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

Summary of product ranges - Commercial applications

6

Caspian UVEC and AC motors p8-11One heating solution for a variety ofapplications, suitable for high, low orceiling-mounted installation.Incorporating EC and AC motortechnology, the UV delivers heat quickly,efficiently and effectively. Heat outputsup to 19.2kW (65500 Btu/h).

Caspian LSTEC motors p18-19The Caspian LST is suitable for a rangeof low level installation projects in anyNHS Estates premises includinghospitals, clinics, surgeries and otherhealth care premises.

Caspian SkylineEC and AC motors p24-25Caspian Skyline fan convector fitssleekly into a 600mm x 600mm ceilingtile, providing easy access for bothinstallation and maintenance. Usingcurrent EC technology, it deliversdiscreet heating in schools, retail or foodunits and plumbs easily into the centralheating system. Heat outputs up to5.1kW(17500Btu/h).

Skyline®

AC motors p26The ceiling-mounted Skyline® providesthe perfect solution to heating largercommercial spaces. Units install simplyinto a standard 600mm x 600mmceiling tile space. There is also an all-electric model available. Heat outputsup to 5.5kW (18800 Btu/h).

Ecovector®/Sterling High AC motors p28-29Designed for unobtrusive fixing at highlevel and ideal for retail units, officesand nurseries. Both hydronic andelectric versions available plus a lowvoltage model for bathrooms. Heatoutputs up to 4.0 kW (13500 Btu/h).

SterlingElectric heaters p23Designed for unobtrusive fixing at highlevel and ideal for retail units, officesand nurseries. Heat outputs up to3.0kW. Hydronic versions available.

Caspian UVCEC and AC motors p12-17Heating only fan convector/fan coilproduct capable of being concealed onor behind walls at high or low level,within ceiling voids and on or belowfloors. Incorporating EC motortechnology the Universal delivers heatquickly, efficiently and effectively. Heatoutputs up to 14.5kW (49200 Btu/h).

Caspian HighAC motors p20-22Designed for unobtrusive fixing at highlevel, Caspian’s rapid response heatingis ideal for heating the large areas ofschools, churches, care homes, libraries,offices, and hospitals. Heat outputs upto 14.4kW (49200 Btu/h).

Sum

mar

y of

pro

duct

ran

ges

- Com

mer

cial

app

licat

ions

www.SmithsEP.co.uk/commercial

Caspian Low AC motors p20-22A floor or wall-mounted fan convectordeveloped for a diversity of applicationsin commercial installations. Available ina range of eight models and a lowsurface temperature casing for completesafety. Heat outputs up to 14.4kW(49200 Btu/h).

Caspian FFEC and AC motors p8-11Probably the most popular style ofcommercial fan convector in the UK,with EC technology and heat outputsup to 19.2kW (65500 Btu/h).

Caspian EXTEC and AC motors p8-11An extended version of FF model.Heat outputs up to 19.2kW (65500Btu/h).

Skyline E 4kWElectric heaters p27Like its hydronic sibling, this is designedfor unobtrusive fixing at high level andis ideal for retail units, showrooms andnurseries. Allows maximum use of wallspace with a safe, high-level heat source.Heat outputs up to 4.0kW. Hydronicversions available.

Page 7: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

7

Sum

mar

y of

pro

duct

ran

ges

- Com

mer

cial

app

licat

ions

www.SmithsEP.co.uk/commercial

Applications chartDomesticRoom Best 444 Better 44 Good 4Kitchen/Utility Room Space Saver Plinth Ecovector® High Ecovector® Low Sterling High Eco-Powerad® Low

Bathroom/En-suite Space Saver Plinth Ecovector® High Sterling HighCloakroom Ecovector® High Sureline® Ecovector® Low Sterling High Eco-Powerad® Low Hall Ecovector® Vertical Ecovector® Low Sureline®

Eco-Powerad® LowLanding Ecovector® Low Ecovector® Vertical Eco-Powerad® Low Living Room/Dining Room Ecovector® Low Ecovector® Vertical Spacemaker Recessed Eco-Powerad® LowFireplace Hydroflame® Conservatory Ecovector® High Ecovector® Vertical Sterling HighBedroom Ecovector® Low Sureline® Ecovector® Vertical Eco-Powerad® LowHome Office/Study Ecovector® High Ecovector® Low Ecovector® Vertical Sterling High Eco-Powerad® Low

CommercialRoom Best 444 Better 44 Good 4Showroom Caspian UV/UVC/FF Skyline® Ceiling High Caspian Low Caspian High Ecovector® Sureline®

Caspian Skyline®

Shop Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Caspian Skyline® Sterling High

Entrance Hall/Corridor Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Sureline®

Sterling High Spacemaker Recessed

Reception Ecovector® Low Ecovector® Vertical Ecovector® High Eco-Powerad® Low Sureline® Sterling High Caspian High

Waiting Room Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Caspian Low Sterling High

Meeting Room/Hall/Club Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Caspian Skyline® Sterling High

Changing Room Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Caspian Skyline® Sterling High

Public House Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Caspian Skyline® Sterling High

Place of Worship Caspian UV/UVC/FF/EXT Ecovector® Low Ecovector® Vertical Caspian High Eco-Powerad® Low Sureline®

Caspian Low

School, Nursery Caspian UV/UVC/FF/EXT Skyline® Ceiling Ecovector® High Caspian LST/LL/HL Caspian High Sterling High Caspian Skyline® Sterling High

Care Home, Hospital Caspian UV/UVC/FF Skyline® Ceiling Ecovector® High Caspian Universal LST Caspian High Sterling High Caspian Skyline® Sterling High Sureline®

Library Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Low Caspian High Ecovector® High Eco-Powerad® Low Caspian Skyline® Sterling High

Page 8: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

8

1. Commercial fan convectors

CaspianCaspian by Smith’s is a range of fan convectors suitable for all kinds of commercialapplications, from churches to office developments, with the ability rapidly heat largeareas with much greater efficiency than other heat emitters. Caspian fan convectors areboth a practical and high quality heating solution for any commercial project.

Incorporating the latest EC motor technology, which can result in running-cost savings ashigh as 80%, and with variable speed control as standard, the Caspian delivers heatquickly and quietly. AC motor models are available on request.

Like all Smith’s fan convectors, Caspians are compatible with most types of wet centralheating systems, functioning equally efficiently with conventional boilers, biomasstechnology or ground or air source heat pumps.

1.Co

mm

erci

al f

an c

onve

ctor

s

www.SmithsEP.co.uk/commercial

Caspian UV, FF and EXT

Motor

EC or AC

EC motors are BMS compliant

Finish

Casing: zinc-coated steel 1.2mm. Polyester powdercoated: white RAL 9010

Available to special order in any colour

Available with anti-microbial or anti-bacterial paint

Filter

Class G3, 100% polyester, non-washable

Installation

• Suitable for two-pipe central heating systems

• Maximum installation height for high or ceiling mounting - 4m to underside

• Pipework access holes on the rear and underside

• Key operated front access panels

• Bleed valve accessible on removal of front casing

• Unit must be earthed

Commissioning

Check water is hot enough to activate the low temperature cut-outthermostat

Controls

Variable heat output controller (mounted within the product)

Accessories

External control harness (for up to 4 products)

Plinth (150mm high) to suit each model, available in black or white

Adjustable low temperature cut-out (30°C to 90°C)

Wall mounted room thermostat

Proportional heat output controller

22mm flexible hoses (pair)

External controlharness

Plinth

Adjustable lowtemperaturecut-out

Wall mounted roomthermostat

Proportional heatoutput controller

22mm flexible hosesSee Glossary on page 46 for further information on Accessories

Principal Accessories

Caspian UV Caspian FF

Caspian EXT

Page 9: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

9

Heat Output testing based on BS EN442 using mean water temperature, 18°C entering air temperature, 10 deg temperature drop.

Model Heat Output at 80° Heat Output at 75° Heat Output at 70°

Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU)

Caspian 60 3.2 (10900) 4.5 (15500) 5.9 (20000) 2.9 (9900) 4.1 (14000) 5.3 (18100) 2.6 (8800) 3.7 (12500) 4.8 (16200)

Caspian 90 5.2 (17700) 7.8 (26500) 10.3 (35200) 4.8 (16300) 7.2 (24600) 9.6 (32800) 4.4 (15000) 6.7 (22700) 8.9 (30400)

Caspian 120 6.7 (22700) 10.7 (36500) 14.5 (49400) 6.1 (20937) 9.6 (32968) 13.2 (45000) 5.6 (19100) 8.7 (29800) 11.9 (40600)

Caspian 150 14.8 (50500) 15.4 (52500) 16.2 (55300) 13.7 (46700) 14.2 (48500) 15.2 (51900) 12.5 (42700) 13.1 (44700) 14.0 (47800)

Caspian 180 17.2 (58700) 18.2 (62100) 19.2 (65500) 16.2 (55300) 17.0 (58000) 18.0 (61400) 14.9 (50800) 15.7 (53600) 16.7 (57000)

Model Heat Output at 65° Heat Output at 60° Heat Output at 55°

Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU)

Caspian 60 2.3 (7800) 3.2 (11100) 4.2 (14300) 2.0 (6800) 2.8 (9600) 3.6 (12400) 1.7 (5800) 2.4 (8200) 3.1 (10600)

Caspian 90 3.9 (13500) 6.0 (20400) 8.0 (27300) 3.5 (11900) 5.3 (18000) 7.1 (24200) 3.0 (10400) 4.6 (15800) 6.2 (21100)

Caspian 120 4.9 (16600) 7.7 (26400) 10.6 (36200) 4.1 (14100) 6.8 (23200) 9.4 (32000) 3.4 (11600) 5.8 (19700) 8.1 (27700)

Caspian 150 11.3 (38600) 11.9 (40600) 12.8 (43700) 9.9 (33800) 10.8 (36900) 11.6 (39600) 8.8 (30000) 9.7 (33100) 10.4 (35500)

Caspian 180 13.6 (46400) 14.4 (49100) 15.4 (52500) 12.4 (42300) 13.3 (45400) 14.1 (48100) 11.3 (38600) 12.0 (40900) 12.8 (43700)

Model Heat Output at 50° Heat Output at 45° Heat Output at 40°

Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU)

Caspian 60 1.4 (4800) 2.0 (6800) 2.5 (8700) 1.1 (3800) 1.5 (5100) 1.9 (6300) 0.8 (2700) 1.0 (3400) 1.2 (4000)

Caspian 90 2.6 (8800) 3.9 (13400) 5.3 (18000) 2.0 (7000) 3.1 (10500) 4.1 (14000) 1.5 (5100) 2.2 (7500) 2.9 (10000)

Caspian 120 2.7 (9000) 4.8 (16300) 6.9 (23500) 2.0 (6700) 3.7 (12600) 5.4 (18400) 1.3 (4400) 2.6 (8900) 3.9 (13400)

Caspian 150 7.5 (25600) 8.2 (28000) 9.0 (30700) 6.2 (21200) 6.9 (23500) 7.5 (25600) 4.8 (16400) 5.4 (18400) 6.1 (21800)

Caspian 180 9.8 (33400) 10.5 (35800) 11.2 (38200) 8.4 (28700) 9.1 (31100) 9.4 (32100) 6.6 (22500) 7.3 (24900) 7.8 (26600)

Model Total Power Consumption

Flow & Return Mains Flexible Isolation Fused Low Medium High Water CapacityConnections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Watts) (Litres)

Caspian 60 22mm n/a n/a n/a n/a 3A 8 24 40 0.92

Caspian 90 22mm n/a n/a n/a n/a 3A 15 43 70 1.50

Caspian 120 22mm n/a n/a n/a n/a 3A 13 62 110 2.08

Caspian 150 22mm n/a n/a n/a n/a 3A 20 144 177 2.54

Caspian 180 22mm n/a n/a n/a n/a 3A 26 124 220 3.18

Model Sound Levels

High Medium Low Casting Fan(dBA) (dBA) (dBA) Colour Only

Caspian 60 50 42 33 White n/a

Caspian 90 53 42 34 White n/a

Caspian 120 58 46 35 White n/a

Caspian 150 59 47 36 White n/a

Caspian 180 59 48 38 White n/a

Correction factors

Mean Water Temperature °C

EATºC 80 to 40

15 1.10

21 0.93

Temperature Drop °C

20 15 10 5

Factor 0.89 0.95 1.00 1.04

Measured at 3m in front of floor mounted model.

Model Packed Weight Caspian UV 60 23KG Caspian UV 90 36KG Caspian UV 120 45KG Caspian UV 150 60KG Caspian UV 180 78KG

1.Co

mm

erci

al f

an c

onve

ctor

s

www.SmithsEP.co.uk/commercial

Model Packed Weight Caspian FF 60 24KG Caspian FF 90 39KG Caspian FF 120 46KG Caspian FF 150 61KG Caspian FF 180 76KG

Model Packed Weight Caspian EXT 60 30KG Caspian EXT 90 49KG Caspian EXT 120 58KG Caspian EXT 150 76KG Caspian EXT 180 95KG

1. Commercial fan convectors

Page 10: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

10

1. Commercial fan convectors

Caspian

1.Co

mm

erci

al f

an c

onve

ctor

s

www.SmithsEP.co.uk/commercial

Caspian EXT

Caspian FF

Our active, innovative approach to new product development gives us the ability tocreate bespoke heating products for our clients and partners, developing specific one-offfan convector solutions for the demands of your project, should you require.

The Caspian range of fan convectors includes the UV, suitable for all locations, the FF,probably the most popular style of commercial fan convector in the UK, and the EXT, anextended FF model.

Page 11: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

11

Caspian UV mounted low Caspian UV mounted high Caspian UV ceiling-mounted

1.Co

mm

erci

al f

an c

onve

ctor

s

www.SmithsEP.co.uk/commercial

Caspian diagrams showing different options

The Caspian UV, one heating solution, suitable for high, low or ceiling-mountedapplications, you can even turn it upside down.

Caspian UV

1. Commercial fan convectors

Page 12: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

12

1. Commercial fan convectors

Caspian UVC

The Caspian UVC fan convector was developed for recessed or concealed heatingprojects. This is another versatile heating solution from Smith’s, suitable for high, low orceiling concealed installations and the UVC can even be turned upside down.

Compatible with all types of wet central heating systems and any commercial or domesticair source heat pump project, the Caspian UVC has four different main accessories. Theyfunction together in any combination to create the recessed or concealed heatingsolution required, depending on the project specification. AC motor models are availableon request.

The four main accessories (see p14) comprise: spigot inlet/outlets; cranked ducts, 90° forleft or right-handed use; a 1m adjustable straight air inlet/outlet duct, which can be usedalone or with additional lengths; and an inlet/outlet grille.

www.SmithsEP.co.uk/commercial

1.Co

mm

erci

al f

an c

onve

ctor

s

Listed buildings, including places of worship, hotels and stately homes can benefit from the Caspian UVC

Page 13: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

13 www.SmithsEP.co.uk/commercial

1.Co

mm

erci

al f

an c

onve

ctor

s

Heat Output testing based on BS EN442 using mean water temperature, 18°C entering air temperature, 10 deg temperature drop.

Model Heat Output at 80° Heat Output at 75° Heat Output at 70°

Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU)

Caspian UVC 60 3.2 (10900) 4.5 (15500) 5.9 (20000) 2.9 (9900) 4.1 (14000) 5.3 (18100) 2.6 (8800) 3.7 (12500) 4.8 (16200)

Caspian UVC 90 5.2 (17700) 7.8 (26500) 10.3 (35200) 4.8 (16300) 7.2 (24600) 9.6 (32800) 4.4 (15000) 6.7 (22700) 8.9 (30400)

Caspian UVC 120 6.7 (22700) 10.7 (36500) 14.5 (49400) 6.1 (20937) 9.6 (32968) 13.2 (45000) 5.6 (19100) 8.7 (29800) 11.9 (40600)

Caspian UVC 150 14.8 (50500) 15.4 (52500) 16.2 (55300) 13.7 (46700) 14.2 (48500) 15.2 (51900) 12.5 (42700) 13.1 (44700) 14.0 (47800)

Caspian UVC 180 17.2 (58700) 18.2 (62100) 19.2 (65500) 16.2 (55300) 17.0 (58000) 18.0 (61400) 14.9 (50800) 15.7 (53600) 16.7 (57000)

Model Heat Output at 65° Heat Output at 60° Heat Output at 55°

Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU)

Caspian UVC 60 2.3 (7800) 3.2 (11100) 4.2 (14300) 2.0 (6800) 2.8 (9600) 3.6 (12400) 1.7 (5800) 2.4 (8200) 3.1 (10600)

Caspian UVC 90 3.9 (13500) 6.0 (20400) 8.0 (27300) 3.5 (11900) 5.3 (18000) 7.1 (24200) 3.0 (10400) 4.6 (15800) 6.2 (21100)

Caspian UVC 120 4.9 (16600) 7.7 (26400) 10.6 (36200) 4.1 (14100) 6.8 (23200) 9.4 (32000) 3.4 (11600) 5.8 (19700) 8.1 (27700)

Caspian UVC 150 11.3 (38600) 11.9 (40600) 12.8 (43700) 9.9 (33800) 10.8 (36900) 11.6 (39600) 8.8 (30000) 9.7 (33100) 10.4 (35500)

Caspian UVC 180 13.6 (46400) 14.4 (49100) 15.4 (52500) 12.4 (42300) 13.3 (45400) 14.1 (48100) 11.3 (38600) 12.0 (40900) 12.8 (43700)

Model Heat Output at 50° Heat Output at 45° Heat Output at 40°

Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU)

Caspian UVC 60 1.4 (4800) 2.0 (6800) 2.5 (8700) 1.1 (3800) 1.5 (5100) 1.9 (6300) 0.8 (2700) 1.0 (3400) 1.2 (4000)

Caspian UVC 90 2.6 (8800) 3.9 (13400) 5.3 (18000) 2.0 (7000) 3.1 (10500) 4.1 (14000) 1.5 (5100) 2.2 (7500) 2.9 (10000)

Caspian UVC 120 2.7 (9000) 4.8 (16300) 6.9 (23500) 2.0 (6700) 3.7 (12600) 5.4 (18400) 1.3 (4400) 2.6 (8900) 3.9 (13400)

Caspian UVC 150 7.5 (25600) 8.2 (28000) 9.0 (30700) 6.2 (21200) 6.9 (23500) 7.5 (25600) 4.8 (16400) 5.4 (18400) 6.1 (21800)

Caspian UVC 180 9.8 (33400) 10.5 (35800) 11.2 (38200) 8.4 (28700) 9.1 (31100) 9.4 (32100) 6.6 (22500) 7.3 (24900) 7.8 (26600)

Model Total Power Consumption

Flow & Return Mains Flexible Isolation Fused Low Medium High Water CapacityConnections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Watts) (Litres)

Caspian UVC 60 22mm n/a n/a n/a n/a 3A 8 24 40 0.92

Caspian UVC 90 22mm n/a n/a n/a n/a 3A 15 43 70 1.50

Caspian UVC 120 22mm n/a n/a n/a n/a 3A 13 62 110 2.08

Caspian UVC 150 22mm n/a n/a n/a n/a 3A 20 144 177 2.54

Caspian UVC 180 22mm n/a n/a n/a n/a 3A 26 124 220 3.18

Model Sound Levels

High Medium Low Casting Fan(dBA) (dBA) (dBA) Colour Only

Caspian UVC 60 50 42 33 White n/a

Caspian UVC 90 53 42 34 White n/a

Caspian UVC 120 58 46 35 White n/a

Caspian UVC 150 59 47 36 White n/a

Caspian UVC 180 59 48 38 White n/a

Correction factors

Mean Water Temperature °C

EATºC 80 to 40

15 1.10

21 0.93

Temperature Drop °C

20 15 10 5

Factor 0.89 0.95 1.00 1.04

Measured at 3m in front of floor mounted model.

Model Packed Weight Caspian UVC 60 23KG Caspian UVC 90 36KG Caspian UVC 120 45KG Caspian UVC 150 60KG Caspian UVC 180 78KG

1. Commercial fan convectors

Page 14: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

1. Commercial fan convectors

Caspian UVC

14 www.SmithsEP.co.uk/commercial

Caspian UVC

Motor

EC or AC

EC motors are BMS compliant

Finish

Casing: galvanised steel 1.2mm

Filter

Class G3, 100% polyester, non-washable

Installation

• Suitable for two-pipe central heating systems

• Unit must be earthed

Commissioning

Check water is hot enough to activate the low temperature cut-out

thermostat

Controls

Variable heat output controller (mounted within the product)

Accessories

• Adjustable low temperature cut-out (30°C to 90°C)

• External control harness (for up to four products)

• Proportional heat output controller

• 22mm flexible hoses (pair)

• White powder-coated steel inlet/outlet grille

• Anodised aluminium air inlet/outlet grille

• 90°C cranked air inlet/outlet duct

• 1m adjustable straight air inlet/outlet extension duct

• Circular spigot air inlet/outlet duct

External control harness

Adjustable lowtemperature cut-out

Proportional heat outputcontroller

Principal Accessories

22mm flexible hoses

90° cranked air inlet/outletCircular spigot airlet/outlet duct

Powder-coated steel inlet/outlet grille

1m adjustable straight airinlet/outlet extension duct

Anodised aluminium inlet/outlet grille

See Glossary on page 46 for further information on Accessories

1.Co

mm

erci

al f

an c

onve

ctor

s

Page 15: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

15 www.SmithsEP.co.uk/commercial

UVC90 A = 818

B = 638

UVC 120 A = 1118

B = 938

529

70 AD

J.

'A'63'B'

5789 71

'B'

PIPE CENTRES

ELECTRICAL SUPPLYIN THIS SIDE

314205

76 238

205

ELECTRICAL SUPPLYIN THIS SIDE

46112

1 metre straight air inlet outletextension duct

UVC90 A = 640

B = 632

UVC120 A = 940

B = 932

'B'

'A'

231.3

1000

208

204

UVC90 A = 641

UVC120 A = 941

'A'

207

301

301

206

90° cranked airinlet outlet duct

Anodised aluminiuminlet outlet grille

UVC90 A = 675

B = 614

UVC120 A = 975

B = 914

Louvre Panel R90

'A'

245

222

Ø6.0

87.5 11.5

184

'B'

32

944

232

300 300172

117

Ø197

51

64

Circular spigot air inlet/outlet duct

All dimensions in mm

UVC120 A = 961

'A'

233

7

1.Co

mm

erci

al f

an c

onve

ctor

s

Powder coated steel inletoutlet grille

MAIN UNIT DIMENSIONS

MODEL A BUVC60 518 338UVC90 818 638UVC120 1118 938UVC150 1418 1238UVC180 1718 1538

90º CRANKED DUCT

MODEL AUVC60 341UVC90 641UVC120 941UVC150 1241UVC180 1541

1 METRE STRAIGHT DUCT

MODEL A BUVC60 518 338UVC90 818 638UVC120 1118 938UVC150 1418 1238UVC180 1718 1538

ALUMINIUM GRILLE

MODEL A BUVC60 375 314UVC90 675 614UVC120 975 914UVC150 1275 1214UVC180 1575 1514

CIRCULAR SPIGOT DUCT

MODEL A DUCTSUVC60 344 1UVC90 644 2UVC120 944 3UVC150 1244 4UVC180 1544 5

STEEL GRILLE

MODEL AUVC60 361UVC90 661UVC120 961UVC150 1261UVC180 1561

1. Commercial fan convectors

Page 16: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

16

1. Commercial fan convectors

www.SmithsEP.co.uk/commercial

The Caspian UVC can be installed either on or behind walls at high and low level, inceiling voids and on or under floors. Detailed below are a number of applicationoptions than can be achieved with the Caspian UVC and Accessories. If in doubtplease contact us.

Caspian UVC

Floor mounted application

Air outlet

Air inlet option

Reversible

1.Co

mm

erci

al f

an c

onve

ctor

s

Page 17: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

Suspended with spigots application

Suspended with ducts application

17

Air outlet

Air inlet option

Reversible

www.SmithsEP.co.uk/commercial

1.Co

mm

erci

al f

an c

onve

ctor

s1. Commercial fan convectors

Page 18: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

18

1. Commercial fan convectors

Caspian LST

www.SmithsEP.co.uk/commercial

1.Co

mm

erci

al f

an c

onve

ctor

s

The LST solution for all properties under the Registered Homes Act 1984.

Smith’s Caspian LST fan convector fully complies with the NHS Estates Health GuidanceNotes, "Safe hot water and surface temperatures" (formally known as DN4) and itsoperation and compliance has been independently verified by BSRIA.

The Caspian LST is suitable for a range of low level installation projects in any NHSEstates premises including hospitals, clinics, surgeries and other health care premiseswhere heat emitters whose maximum surface temperature does not exceed 43°C arerequired.

Incorporating the latest EC motor technology, the three models (120, 90 and 60) are allhydronic and plumb into any wet two-pipe central heating system whether conventionalor renewable. The Caspian LST delivers heat quickly, efficiently and effectively and thereis also a range of additional controls and accessories available, as required.

Heat Output testing based on BS EN442 using mean water temperature, 18°C entering air temperature, 10 deg temperature drop.

Model Heat Output at 80° Heat Output at 75° Heat Output at 70°

Low Medium High Low Medium High Low Medium High kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Caspian LST 60 1.0 (3400) 1.6 (5400) 2.2 (7400) 0.9 (3200) 1.4 (4900) 1.9 (6600) 0.8 (2900) 1.3 (4400) 1.7 (5900)

Caspian LST 90 3.0 (10200) 3.5 (11800) 3.9 (13400) 2.8 (9600) 3.2 (11100) 3.7 (12600) 2.6 (9000) 3.0 (10400) 3.5 (11800)

Caspian LST 120 5.0 (17000) 5.3 (18300) 5.7 (19500) 4.7 (16000) 5.1 (17300) 5.5 (18600) 4.4 (15100) 4.8 (16400) 5.2 (17700)

Caspian LST 150 6.2 (21200) 6.7 (22900) 7.2 (24600) 6.0 (20500) 6.5 (22200) 7.0 (23900) 5.7 (19400) 6.2 (21200) 6.7 (22900)

Caspian LST 180 7.7 (26300) 8.2 (28000) 8.7 (29700) 7.5 (25600) 8.0 (27300) 8.5 (29000) 7.2 (24600) 7.7 (26300) 8.2 (28000)

Model Heat Output at 65° Heat Output at 60° Heat Output at 55°

Low Medium High Low Medium High Low Medium High kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Caspian LST 60 0.8 (2600) 1.1 (3900) 1.5 (5100) 0.7 (2400) 1.0 (3400) 1.3 (4400) 0.6 (2200) 0.8 (2900) 1.1 (3600)

Caspian LST 90 2.4 (8100) 2.8 (9500) 3.2 (10800) 2.1 (7300) 2.5 (8500) 2.9 (9800) 1.9 (6400) 2.2 (7600) 2.6 (8800)

Caspian LST 120 4.0 (13700) 4.4 (15100) 4.8 (16500) 3.6 (12200) 4.0 (13700) 4.4 (15200) 3.2 (10800) 3.6 (12300) 4.1 (13900)

Caspian LST 150 5.3 (18100) 5.8 (19800) 6.3 (21500) 4.9 (16700) 5.4 (18400) 5.9 (20100) 4.6 (15700) 5.1 (17400) 5.6 (19100)

Caspian LST 180 6.8 (23200) 7.3 (24900) 7.8 (26600) 6.4 (21800) 6.9 (23500) 7.4 (25300) 6.1 (20800) 6.6 (22500) 7.1 (24200)

Model Heat Output at 50°

Low Medium High kW (Btu/h) kW (Btu/h) kW (Btu/h)

Caspian LST 60 0.6 (1900) 0.7 (2400) 0.8 (2900)

Caspian LST 90 1.6 (5600) 2.0 (6700) 2.3 (7800)

Caspian LST 120 2.8 (9400) 3.2 (10900) 3.7 (12600)

Caspian LST 150 4.2 (14300) 4.7 (16000) 5.2 (17700)

Caspian LST 180 5.7 (19400) 6.2 (21200) 6.7 (22900)

Caspian LST

Page 19: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

19 www.SmithsEP.co.uk/commercial

1.Co

mm

erci

al f

an c

onve

ctor

s

Caspian LSTMotor

EC only

EC motors are BMS compliant

Finish

Casing: zinc-coated steel 1.2mm. Polyester powdercoated: white RAL 9010

Available to special order in any colour

Available with anti-microbial or anti-bacterial paint

Filter

Class G3, 100% polyester, non-washable

Installation

• Suitable for two-pipe central heating systems

• Pipework access holes on the rear and underside

• Key operated front access panels

• Bleed valve accessible on removal of front casing

• Unit must be earthed

Commissioning

Check water is hot enough to activate the low temperature cut-outthermostat

Regulate the flow to achieve maximum performance

Controls

Variable heat output controller (mounted within the product)

Built-in room thermostat

Fan-only

Accessories

External control harness (for up to 4 products)

Plinth (150mm high) to suit each model, available in black or white

Wall mounted room thermostat

22mm flexible hoses (pair)

Caspian LST

Model Total Power Consumption

Flow & Return Mains Flexible Isolation Fused Low Medium High Water CapacityConnections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Watts) (Litres)

Caspian LST 60 22mm n/a n/a n/a n/a 3A 26 41 55 0.92

Caspian LST 90 22mm n/a n/a n/a n/a 3A 33 59 85 1.5

Caspian LST 120 22mm n/a n/a n/a n/a 3A 33 79 125 2.08

Caspian LST 150 22mm n/a n/a n/a n/a 3A 50 119 188 2.58

Caspian LST 180 22mm n/a n/a n/a n/a 3A 66 158 250 3.18

Model Sound Levels

High Medium Low Casting Fan(dBA) (dBA) (dBA) Colour Only

Caspian LST 60 50 43 35 White •

Caspian LST 90 53 45 37 White •

Caspian LST 120 57 48 38 White •

Caspian LST 150 59 47 36 White •

Caspian LST 180 59 47 36 White •

External controlharness

Measured at 3m in front of floor mounted model.

Plinth Wall mounted roomthermostat

22mm flexible hoses

All dimensions in mm

Model A B 60 595 470 90 895 770 120 1195 1070 150 1495 1370 180 1795 1670

Model Packed Weight Caspian LST 60 24KG Caspian LST 90 37KG Caspian LST 120 46KG Caspian LST 150 60KG Caspian LST 180 78KG

Model Pressure Drop

High Medium Low(kPa) (kPa) (kPa)

Caspian LST 60 1.5 1.1 0.9

Caspian LST 90 3.9 2.3 1.6

Caspian LST 120 7.3 5.5 5.3

Caspian LST 150 8.6 6.8 6.2

Caspian LST 180 11.3 8.6 7.9

EAT 20°C, MWT 75°C, 10°C temperature drop

1. Commercial fan convectors

Page 20: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

20

Caspian High & Low

Model Heat Output at 80ºC Heat Output at 75ºC Low Medium High Low Medium High Low Level High Level kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

Caspian LL 60/03 Caspian HL 60/03 3.2 (10900) 3.5 (12000) 3.7 (12800) 2.9 (9900) 3.2 (11000) 3.4 (11600)

Caspian LL 60/04 Caspian HL 60/04 4.0 (13500) 4.5 (15400) 5.1 (17300) 3.6 (12300) 4.1 (14000) 4.6 (15700)

Caspian LL 90/06 Caspian HL 90/06 6.2 (21100) 6.8 (23300) 7.4 (25100) 5.6 (19100) 6.2 (21200) 6.7 (22900

Caspian LL 90/07 Caspian HL 90/07 6.8 (23300) 7.7 (26300) 8.6 (29300) 6.2 (21200 7.0 (23900) 7.8 (26600)

Caspian LL 120/10 Caspian HL 120/10 9.5 (32300) 11.4 (39000) 12.5 (42800) 8.6 (29300) 10.4 (35500) 11.4 (38900)

Caspian LL 120/11 Caspian HL 120/11 10.5 (35700) 12.5 (42800) 13.4 (45800) 9.5 (32400) 11.4 (38900) 12.2 (41600)

Caspian LL 120/12 Caspian HL 120/12 11.4 (39000) 13.4 (45800) 14.4 (49200) 10.4 (35500) 12.2 (41600) 13.1 (44700)

Model Heat Output at 70ºC Heat Output at 65ºC Low Medium High Low Medium High Low Level High Level kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

Caspian LL 60/03 Caspian HL 60/03 2.6 (8800) 2.8 (9700) 3.0 (10300) 2.3 (7800) 2.5 (8600) 2.7 (9200)

Caspian LL 60/04 Caspian HL 60/04 3.2 (10900) 3.6 (12500) 4.1 (14000) 2.8 (9700) 3.2 (11000) 3.6 (12400)

Caspian LL 90/06 Caspian HL 90/06 5.0 (17000) 5.5 (18800) 6.0 (20300) 4.4 (15100) 4.9 (16700) 5.3 (18100)

Caspian LL 90/07 Caspian HL 90/07 5.5 (18800) 6.2 (21300) 6.9 (23700) 4.9 (16700) 5.5 (18900) 6.2 (21000)

Caspian LL 120/10 Caspian HL 120/10 7.7 (26100) 9.3 (31600) 10.1 (34600) 6.8 (23200) 8.2 (28000) 9.0 (30700)

Caspian LL 120/11 Caspian HL 120/11 8.5 (28800) 10.1 (34600) 10.9 (37000) 7.5 (25600) 9.0 (30700) 9.6 (32900)

Caspian LL 120/12 Caspian HL 120/12 9.3 (31600) 10.9 (37000) 11.7 (39800) 8.2 (28000) 9.6 (32900) 10.3 (35300)

Caspian low surface temperature fan convectors have been specially developed for awide range of applications in larger spaces and commercial environments. With the abilityto rapidly heat large areas at low cost, Caspian commercial fan convectors are bothpractical and energy efficient. Fully compatible with renewable energy technology, suchas ground and air source heat pumps, Caspian can also enhance your environmentalcredentials. Supplied as standard in white but can be supplied in any colour.

Low Level

High Level

www.SmithsEP.co.uk/commercial

Model Heat Output at 60ºC Heat Output at 55ºC Low Medium High Low Medium High Low Level High Level kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

Caspian LL 60/03 Caspian HL 60/03 2.0 (6900) 2.2 (7500) 2.3 (8000) 1.7 (6000) 1.9 (6600) 2.0 (7000)

Caspian LL 60/04 Caspian HL 60/04 2.5 (8500) 2.8 (9700) 3.2 (10800) 2.2 (7300) 2.5 (8400) 2.8 (9400)

Caspian LL 90/06 Caspian HL 90/06 3.9 (13200) 4.3 (14600) 4.6 (15800) 3.4 (11500) 3.7 (12700) 4.0 (13700)

Caspian LL 90/07 Caspian HL 90/07 4.3 (14600) 4.8 (16500) 5.4 (18400) 3.7 (12700) 4.2 (14300) 4.7 (16000)

Caspian LL 120/10 Caspian HL 120/10 5.9 (20200) 7.2 (24500) 7.9 (26800) 5.2 (17600) 6.2 (21300) 6.8 (23400)

Caspian LL 120/11 Caspian HL 120/11 6.6 (22400) 7.9 (26900) 8.4 (28700) 5.7 (19500) 6.8 (23300) 7.3 (25000)

Caspian LL 120/12 Caspian HL 120/12 7.2 (24500) 8.4 (28700) 9.0 (30800) 6.2 (21300) 7.3 (25000) 7.9 (26800)

1. Commercial fan convectors1.

Com

mer

cial

fan

con

vect

ors

Page 21: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

21

Model Total Power Consumption Flow & Return Mains Flexible Isolating Fused Low Medium High Water Capacity Low Level High Level Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Watts) (Litres)

Hydronic

Caspian LL 60/03 Caspian HL 60/03 22mm n/a n/a n/a n/a 3A 29 36 51 0.56

Caspian LL 60/04 Caspian HL 60/04 22mm n/a n/a n/a n/a 3A 29 36 51 0.92

Caspian LL 90/06 Caspian HL 90/06 22mm n/a n/a n/a n/a 3A 53 60 98 0.72

Caspian LL 90/07 Caspian HL 90/07 22mm n/a n/a n/a n/a 3A 53 60 98 1.50

Caspian LL 120/10 Caspian HL 120/10 22mm n/a n/a n/a n/a 3A 53 99 114 2.08

Caspian LL 120/11 Caspian HL120/11 22mm n/a n/a n/a n/a 3A 60 114 135 2.08

Caspian LL 120/12 Caspian HL 120/12 22mm n/a n/a n/a n/a 3A 99 135 151 2.08

Model Sound Levels High Medium Low Casing Low Level High Level (dBA) (dBA) (dBA) Colour Fan-Only

Hydronic

Caspian LL 60/03 Caspian HL 60/03 40 37 34 White n/a

Caspian LL 60/04 Caspian HL 60/04 38 35 32 White n/a

Caspian LL 90/06 Caspian HL 90/06 43 40 37 White n/a

Caspian LL 90/07 Caspian HL 90/07 42 40 37 White n/a

Caspian LL 120/10 Caspian HL 120/10 44 42 37 White n/a

Caspian LL 120/11 Caspian HL 120/11 46 44 39 White n/a

Caspian LL 120/12 Caspian HL 120/12 48 46 42 White n/a Sound levels measured at 1.5m.

www.SmithsEP.co.uk/commercial

Model Heat Output at 50ºC Heat Output at 45ºC Low Medium High Low Medium High Low Level High Level kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

Caspian LL 60/03 Caspian HL 60/03 1.5 (5100) 1.6 (5600) 1.7 (5900) 1.2 (3950) 1.3 (4350) 1.4 4650)

Caspian LL 60/04 Caspian HL 60/04 1.8 (6250) 2.1 (7100) 2.3 (8000) 1.4 (4900) 1.6 (5600) 1.8 (6300)

Caspian LL 90/06 Caspian HL 90/06 2.9 (9700) 3.2 (10800) 3.4 (11700) 2.2 (7600) 2.5 (8500) 2.7 (9100)

Caspian LL 90/07 Caspian HL 90/07 3.2 (10800) 3.6 (12200) 4.0 (13600) 2.5 (8500) 2.8 (9600) 3.1 (10600)

Caspian LL 120/10 Caspian HL 120/10 4.4 (15000) 5.3 (18100) 5.8 (19800) 3.4 (11700) 4.2 (14200) 4.6 (15600)

Caspian LL 120/11 Caspian HL 120/11 4.8 (16500) 5.8 (19800) 6.2 (21200) 3.8 (13000) 4.6 (15600) 4.9 (16600)

Caspian LL 120/12 Caspian HL 120/12 5.3 (18100) 6.2 (21200) 6.7 (22800) 4.2 (14200) 4.9 (16700) 5.2 (17900)

Model Heat Output at 40ºC Low Medium High Low Level High Level kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

Caspian LL 60/03 Caspian HL 60/03 0.9 (3050) 1.0 (3400) 1.1 (3600)

Caspian LL 60/04 Caspian HL 60/04 1.1 (3800) 1.3 (4350) 1.4 (4900)

Caspian LL 90/06 Caspian HL 90/06 1.7 (5900) 1.9 (6600) 2.1 (7100)

Caspian LL 90/07 Caspian HL 90/07 1.9 (6600) 2.2 (7400) 2.4 (8300)

Caspian LL 120/10 Caspian HL 120/10 2.7 (9100) 3.2 (11000) 3.5 (12100)

Caspian LL 120/11 Caspian HL 120/11 2.9 (10000) 3.5 (12100) 3.8 (12900)

Caspian LL 120/12 Caspian HL 120/12 3.2 (11000) 3.8 (12900) 4.1 (13900)

Heat outputs tested in accordance with BS4856 using mean water temperature, 18°C entering air temperature,10°C temperature drop.

Correction factors

Mean Water Temperature °C

EATºC 80 to 40

15 1.10

21 0.93

Temperature Drop °C

20 15 10 5

Factor 0.89 0.95 1.00 1.04

Model Packed Weight Caspian LL 60/03 28KG Caspian LL 60/04 28KG Caspian LL 90/06 37KG Caspian LL 90/07 39KG Caspian LL 120/10 48KG Caspian LL 120/11 48KG Caspian LL 120/12 48KG Caspian HL 60/03 24KG Caspian HL 60/04 24KG Caspian HL 90/06 37KG Caspian HL 90/07 39KG Caspian HL 120/10 46KG Caspian HL 120/11 46KG Caspian HL 120/12 46KG

1.Co

mm

erci

al f

an c

onve

ctor

s1. Commercial fan convectors

Page 22: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

22

Caspian High & LowMotorAC onlyFinishCasing: zinc-coated steel 1.2mm Polyester powder-coated: white RAL 9010Available to special order in any colourAvailable with anti-microbial paint or anti-bacterial paintFilterClass G3, 100% polyester, non-washableInstallation• Suitable for two-pipe central heating systems• Mounting brackets supplied for both models (low level models can sit on the floor)• Maximum installation height for high level mounted model - 4m to underside• Pipework access holes on the rear and underside (Low) and top (High)• Key operated front access panels• Bleed valve accessible on removal of front casing• Tamperproof control panel (low level models only)• Unit must be earthedCommissioningCheck water is hot enough to activate the low temperature cut-out thermostatControlsRocker switch - low/medium/high heat outputIlluminated rocker switch - on/offFacility to connect room thermostatLow temperature cut-out thermostat set to energise fan at approximately 35°CAccessoriesWall mounted room thermostatAdjustable low temperature cut-out (30°C to 90°C)Thermostat (T1) & auto speed control (T2) Low only

Model A 60 595 90 895 120 1195

Caspian Low Level

66

Pipe Centres 176

250

245

Electrical supply in this side

A

530

Caspian High Level

All dimensions in mm

www.SmithsEP.co.uk/commercialSee Glossary on page 46 for further information on Accessories

1. Commercial fan convectors1.

Com

mer

cial

fan

con

vect

ors

Adjustable lowtemperaturecut-out

Thermostat and autospeed control

Wall mounted roomthermostat

Tamperproof controlpanel

Caspian High & Low

Accessories

Page 23: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

23 www.SmithsEP.co.uk/commercial

1.Co

mm

erci

al f

an c

onve

ctor

s1. Commercial fan convectors

Sterling

Sterling Electric E 3kW

Sterling Electric

Motor

AC only

Finish

Outer casing 0.9mm zinc-coated steel. Polyester powdercoated.

Paint specification: textured white, BS 4800 00A01 18%gloss

Side panels: Polymer - white

Installation

• Recommended installation height 2.3m (7ft 6") to underside

• Not suitable for bathrooms and other high humidity areas

• Angled mounting (optional)

• 13 amp fused spur required

• Unit must be earthed

Controls

Rocker switches for fan and element - fan-only/1kW/2kW/3kW

Built-in room thermostat

Overheat protection: thermal cut-out.

Manual reset procedure: switch power off at mains, wait 20minutes, switch power on.

Heat Output (kW)

Power Consumption (kW)

Fused Mains Sound Casing Fan-Only Model Spur Cable (m) Levels (dBA) Colour

Electric

Sterling E 3kW 1kW/2kW/3kW 1kW/2kW/3kW 13A n/a 39 White •

The Sterling fan-assisted electric heater is a great low cost solution providing effective anddependable heating for both small and large commercial areas, fitted unobtrusively abovehead height. It has been designed for rooms with limited lower wall space, such as shopsand libraries, in mind.

Additional information

Electric fan-assisted heaters cost around 15p per hour for each 1kW of heat.

Hydronic versions available - see page 28

Sound levels measured at 1.5m with the product installed at 2.2m high

All dimensions in mm

Model Packed Weight Sterling E 3kw 4KG

See Glossary on page 46 for further information on Accessories

Page 24: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

24 www.SmithsEP.co.uk/commercial

1. Commercial fan convectors1.

Com

mer

cial

fan

con

vect

ors

Caspian Skyline

The latest addition to the Caspian range, Caspian Skyline fits into a 600mm x 600mmceiling tile, providing easy access for both installation and maintenance. It’s suitable forprojects in schools, retail or food units or where the heating needs to complement therest of the premise. Using current EC technology, it delivers discreet heating and plumbseasily into the central heating system.

The Caspian Skyline has been developed to provide a more easily installed ceiling tile fanconvector to complement the Smith’s range of Caspian commercial fan convectors andmay be used alone or in tandem with other Smith’s products. Plumbing easily into anywet central heating system, the Caspian Skyline will also work effectively and efficientlywith renewable heat sources, such as air or ground source heat pumps.

Correction factors

Mean Water Temperature °C

EATºC 80 to 40

15 1.10

21 0.93

Temperature Drop °C

20 15 10 5

Factor 0.89 0.95 1.00 1.04

Heat outputs tested in accordance with BS EN442 using mean water temperature, 18°C entering air temperature, 10°C temperature drop.

Model Heat Output at 80° Heat Output at 75° Heat Output at 70°

Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU)

Caspian Skyline CT60 3.1 (10500) 4.1 (14000) 5.1 (17500) 2.7 (9200) 3.7 (12500) 4.6 (15700) 2.3 (8000) 3.2 (11000) 4.1 (14000)

Model Heat Output at 65° Heat Output at 60° Heat Output at 55°

Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU)

Caspian Skyline CT60 2.3 (7700) 2.9 (10000) 3.6 (12200) 2.2 (7400) 2.6 (8900) 3.1 (10500) 1.5 (5000) 2.0 (6900) 2.6 (8700)

Model Heat Output at 50° Heat Output at 45° Heat Output at 40°

Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU)

Caspian Skyline CT60 0.8 (2600) 1.4 (4800) 2.1 (7000) 0.5 (1700) 0.9 (3000) 1.3 (4400) 0.2 (800) 0.4 (1300) 0.5 (1700)

Page 25: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

25 www.SmithsEP.co.uk/commercial

Caspian Skyline

Motor

EC and AC

EC motors are BMS compliant

Finish

Casing: galvanised steel 1.2mm

Grille

Eggcrate core, white RAL 9010 complete with touch catches

Filter

Class G3, 100% polyester, non-washable

Installation

• Suitable for two-pipe central heating systems

• Maximum installation height – 4m to underside

• Unit must be earthed

Commissioning

Check water is hot enough to activate the low temperature cut-outthermostat

Controls

Variable heat output controller (mounted within the product)

Accessories

Adjustable low temperature cut-out (30°C to 90°C)

External control harness (for up to 4 products)

22mm flexible hoses (pair)

All dimensions in mm

Sound levels measured at 3.0m.

Model Total Power Consumption

Flow & Return Mains Flexible Isolation Fused Low Medium High Water CapacityConnections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Watts) (Litres)

Caspian Skyline CT60 22mm n/a n/a n/a n/a 3A 8 24 40 0.75

Model Packed Weight Caspian Skyline CT60 20KG

215 Heater Unit Grille

538

110275

570 Hanging Ctrs

50 5565

45

538

204

595563

595 595

500Hanging

Ctrs

External controlharness

Adjustable lowtemperaturecut-out

22mm flexible hoses

Model Sound Levels

High Medium Low Grille Fan(dBA) (dBA) (dBA) Colour Only

Caspian Skyline CT60 48 40 34 White n/a

See Glossary on page 46 for further information on Accessories

1.Co

mm

erci

al f

an c

onve

ctor

s1. Commercial fan convectors

Page 26: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

Sound Levels Normal Boost Model (dBA) (dBA) Casing Colour Fan-Only

Hydronic

Skyline CT18 44 55 White •

Sound levels measured at 1.5m.

26

Skyline®

The Skyline® fits neatly into existing ceiling space - replacing a 600mm x 600mm ceilingtile and because it is ceiling mounted, it saves valuable wall space - particularly importantin retail units. It is unobtrusive and effective. Supplied as standard in white but casing canbe supplied in any colour.

Power Consumption Flow and Return Main Flexible Isolating Fused Normal Boost Water Capacity Model Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres)

Hydronic

Skyline CT18 22mm 1.5m n/a n/a n/a 3A 50 70 0.9

Skyline CT18Motor

AC only

Finish

Outer casing 0.7mm zinc-coated steel. Polyester powder-coated Paint specification: textured white, BS 4800 00A01 18% gloss

Installation

• Maximum installation height 3.2m (10'6") to underside

• Installed to 180mm - penetration depth in recess (excluding fittings)

• Four air inlet options: room only, void only, room and void, fresh air (spigot required)

• 600mm side clearance required

• Fixing brackets (4) supplied for connection to 6mm threaded rods or chains(rods and chains - not supplied)

• Blanking plates (2) supplied for air circulation options

• Unit must be earthed

• Supplied with remote operating switch

• Suitable for two-pipe central heating systems only

Commissioning

Check water temperature is hot enough to activate low temperature cut-out (LTC). The inclusion of an automatic air vent at the highest point isrecommended to avoid possible air locks

Controls

Two rocker fan switches - normal/off/boost, fan-heating/fan-only.

Low temperature cut-out thermostat set to energise fan at approximately 35°C

Accessories

Wall mounted room thermostat

Fresh air inlet spigot to suit 100mm flexible hose

Skyline CT1822

Pipe Centres

28

90

22mmFlow and Return Pipes

90

100

Heat exchangerdrain off valve

Outlet panel fits overceiling tile frame

Air in void or roomdamper at both ends

600

542

516centres

498

cent

res

600555

280

45 cent

res

Fixing points

www.SmithsEP.co.uk/commercial

Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

Skyline CT18 3.5 (11900) 5.5 (18800) 3.1 (10700) 5.0 (16900) 2.8 (9600) 4.4 (15000) 2.5 (8700) 3.9 (13200)

Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

Skyline CT18 2.3 (7900) 3.3 (11400) 2.1 (7000) 3.0 (10100) 1.8 (6000) 2.6 (8900) 1.5 (5100) 2.2 (7600)

Heat Output at 40ºC Normal Boost Model kW (Btu/h) kW (Btu/h)

Hydronic

Skyline CT18 1.2 (4100) 1.8 (6300)

Heat outputs tested in accordance with BS4856 using entering water temperatureand 340 l/h (75gph) flow rate.

Model Packed Weight Skyline CT18 20KG

See Glossary on page 46 for further information on Accessories

1. Commercial fan convectors1.

Com

mer

cial

fan

con

vect

ors

Page 27: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

27 www.SmithsEP.co.uk/commercial

1.Co

mm

erci

al f

an c

onve

ctor

s

Skyline® E 4kW

Multiple positions (14) for suspension points

507

151

15600

600264

248

cent

res

Skyline® E 4kW

Finish

Outer casing 0.9mm zinc-coated steel. Polyester powder-coated Paint specification: textured white, BS 4800 00A01 18% gloss

Installation

• Maximum installation height 3.2m (10'6") to underside

• Minimum 150mm void space required for recessedinstallation

• Not suitable for bathrooms and other high humidity areas

• Two air inlet options: room only, room and void

• Maximum flexibility in installation: only 600mm - sideclearance required

• Facility for connection to 6mm threaded rod or chains (rods and chains - not supplied)

• 20 amp fused spur required

• Unit must be earthed

• Supplied with remote operating switch

Controls

Rocker switches for fan and element

Overheat protection: thermal cut-out. Manual reset procedure:switch power off at mains, wait 5 minutes, switch power on

Accessories

Surface mounting kit - 135mm. Provides a complete four-sided trim when fitted to a solid ceiling

Ceiling tile spacer - 85mm. Provides semi-recessed profile tomatch Skyline CT18 when used in ceiling tile frame

Room thermostats used in conjunction with Skyline E 4kWmust be rated at 20A minimum

The electric Skyline® fits neatly into existing ceiling space - replacing a 600mm x 600mmceiling tile and because it is ceiling mounted, it saves valuable wall space - particularlyimportant in retail units. It is unobtrusive and effective. Like its hydronic cousin, this high-output fan convector effectively heats large areas. Supplied as standard in white but canbe supplied in any colour.

Heat Output (kW) Power Consumption (kW) Fused Mains Sound Casing Fan-Only Model Normal Boost Normal Boost Spur Cable (m) Levels (dBA) Colour Electric

Skyline E 4kW 4.0 4.0 4.1 4.1 20A 1.5 40 White n/a

Skyline®

Additional information

Electric fan-assisted heaters cost around 15p per hour for each 1kW of heat.Hydronic model available.

1. Commercial fan convectors

Page 28: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

28 www.SmithsEP.co.uk/commercial

The Ecovector® and Sterling Hydronic and Hydronic Low Voltage fan convectors provideeffective and dependable heating for both small and large commercial areas, fittedunobtrusively above head height. They work particularly well in shops and libraries, wherelower wall space is limited. Supplied as standard in white but casing can be supplied in anycolour.

Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

Ecovector HL 1000 1.0 (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400)

Ecovector HL 2300 2.3 (7850) 3.1 (10500) 2.1 (7000) 2.8 (9400) 1.9 (6400) 2.5 (8500) 1.7 (5700) 2.1 (7300)

Ecovector HL 2900 2.9 (10000) 4.2 (14500) 2.7 (9200) 4.0 (13500) 2.5 (8500) 3.5 (12000) 2.3 (7700) 3.2 (11000)

Ecovector HL 4000 4.0 (13500) 5.3 (18000) 3.7 (12500) 4.8 (16500) 3.3 (11300) 4.4 (15100) 3.0 (10400) 4.1 (13900)

Sterling 1000-240V 1.0 (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400)

Hydronic Low Voltage

Ecovector HL 1000-12V 1.0 (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400)

Sterling 1000-12V 1.0 (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400)

Ecovector®

/Sterling High

Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

Ecovector HL 1000 0.7 (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000)

Ecovector HL 2300 1.4 (4800) 1.9 (6600) 1.4 (4700) 1.8 (6300) 1.2 (4100) 1.6 (5500) 1.1 (3600) 1.4 (4800)

Ecovector HL 2900 2.1 (7200) 2.9 (9800) 1.9 (6600) 2.6 (8900) 1.6 (5400) 2.3 (7800) 1.4 (4750) 2.0 (6800)

Ecovector HL 4000 2.7 (9100) 3.4 (11500) 2.4 (8200) 3.2 (10900) 2.1 (7150) 2.8 (9600) 1.8 (6300) 2.5 (8400)

Sterling 1000-240V 0.7 (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000)

Hydronic Low Voltage

Ecovector HL 1000-12V 0.7 (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000)

Sterling 1000-12V 0.7 (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000)

Heat Output at 40ºC Normal Boost Model kW (Btu/h) kW (Btu/h)

Hydronic

Ecovector HL 1000 0.4 (1350) 0.5 (1800)

Ecovector HL 2300 0.9 (3000) 1.2 (4000)

Ecovector HL 2900 1.2 (4000) 1.7 (5700)

Ecovector HL 4000 1.6 (5300) 2.1 (7000)

Sterling 1000-240V 0.4 (1350) 0.5 (1800)

Hydronic Low Voltage

Ecovector HL 1000-12V 0.4 (1350) 0.5 (1800)

Sterling 1000-12V 0.4 (1350) 0.5 (1800)

Heat outputs tested in accordance with BS4856 using entering water temperatureand 340 l/h (75gph) flow rate.

Sound levels measured at 1.5m.

1. Commercial fan convectors1.

Com

mer

cial

fan

con

vect

ors

Sound Levels Normal Boost Casing Model (dBA) (dBA) Colour Fan-Only

Hydronic

Ecovector HL 1000 32 40 White •

Ecovector HL 2300 34 50 White •

Ecovector HL 2900 37 51 White •

Ecovector HL 4000 39 52 White •

Sterling 1000-240V 32 40 White •

Hydronic Low Voltage

Ecovector HL 1000-12V 32 39 White •

Sterling 1000-12V 32 39 White •

Page 29: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Model Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres)

Hydronic

Ecovector HL 1000 15mm 1.5m n/a n/a n/a 3A 20 25 0.28

Ecovector HL 2300 15mm 1.5m n/a n/a n/a 3A 20 32 0.32

Ecovector HL 2900 15mm 1.5m n/a n/a n/a 3A 33 50 0.52

Ecovector HL 4000 22mm 1.5m n/a n/a n/a 3A 40 60 1.04

Sterling 1000-240V 15mm 1.5m n/a n/a n/a 3A 20 25 0.28

Hydronic Low Voltage

Ecovector HL 1000-12V 15mm 0.45m • n/a n/a 3A 20 25 0.28

Sterling 1000-12V 15mm 0.45m • n/a n/a 3A 20 25 0.28

Wall mounted roomthermostat

Sterling Hydronic 1000-240V, 1000-12V

276

Electrical supplyin this side

124

37

96

112

540

5325

80Pipe Centres

29 www.SmithsEP.co.uk/commercial

Ecovector® HL 4000

276

Electrical supplyin this side

124

37

96

112

8825

80Pipe Centres

A

Pipe Centres690

Electrical supplyin this side

124

100

78

35

112276

All dimensions in mm

Model A 1000 470 1000-12V 470 2300 781 2900 1062 4000 1412

Ecovector® HL 1000, 1000-12V, 2300, 2900A

Model Packed Weight Ecovector HL 1000 7KG Ecovector HL 2300 11KG Ecovector HL 2900 15KG Ecovector HL 4000 18KG Sterling 1000-240v 7KG

Ecovector HL 1000-12V 8KG Sterling 1000-12V 8KG

Ecovector®/Sterling High Level

Motor

AC only

Finish

Front casing: zinc-coated steel. Polyester powder-coated: texturedwhite BS 4800 00A01 18% gloss

Side panels: polymer eggshell white

Installation

• Maximum installation height 2.1m (6’11”) to underside

• No top or side clearance required

• Unit must be earthed (except model 1000-12V)

• Suitable for two-pipe central heating systems

• Patress box not supplied for transformer (model 1000-12V)

Commissioning

Check water is hot enough to activate the low temperature cut-outthermostat. The inclusion of an automatic air vent at the highestpoint is recommended to avoid possible air locks

Controls

Two rocker switches - normal/off/boost, heating/fan-only

Low temperature cut out thermostat, set to energise fan atapproximately 35°C

Accessory

Wall mounted room thermostat

See Glossary on page 46 for further information on Accessories

1.Co

mm

erci

al f

an c

onve

ctor

s1. Commercial fan convectors

Page 30: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

Summary of product ranges - Domestic applications

30

Sum

mar

y of

pro

duct

ran

ges

- Dom

esti

c ap

plic

atio

ns

Space Saver - HydronicPlinth heaters p42-44

Providing an alternative to the traditional radiator, the Smith’s Space Saver sits neatly inthe plinth at the bottom of your kitchen units to create space for extra cupboards, morework surface and additional appliances. Heat outputs up to 2.4kW (8200 Btu/h).

Hydroflame®

Fan convector p38-40

The Hydroflame® hydronic flame-effect fan convectors provide the visual appeal of a realfire but are safer and more energy efficient and fit on any internal or external wall surface,into a fireplace opening or in front of a fireplace surround, affording the homeowner ahuge degree of flexibility for room design and layout. Heat outputs up to 2.0kW (6800 Btu/h).

Ecovector® Vertical Fan convectors p36Designed for installation in narrowspaces like hallways, and other smallerrooms, this vertical low-level wall-mounted fan convector includeswireless thermostatic control. Heatoutput up to 2.6kW (8800 Btu/h).

Eco-Powerad®

Fan convector p35The fan convector of the future –energy efficient, responsive and capableof installation within most wet centralheating systems driven by either boilersor low temperature renewabletechnology. Heat outputs up to 3.9kW(13200 Btu/h).

SpacemakerFan convector p37

Floor-fitted fan convector, ideal forentrance halls and lobbies where wallspace is limited. Heat outputs up to1.6kW (5500 Btu/h).

Sureline®

Natural convectors p41A natural convector fitted at skirtinglevel - the ideal form of perimeterheating, providing gentle low-levelwarmth anywhere from hallways andconservatories to airing cupboards. Heat outputs up to 820W (2520Btu/h)per metre.

Ecovector®/Sterling High Fan convector p32-33Designed for unobtrusive fixing at highlevel and ideal for a wide range of livingareas. Both hydronic and electricversions available plus a low voltagemodel for bathrooms. Heat outputs upto 4.0 kW (13500 Btu/h).

Ecovector® Low Fan convector p34Combining stylish good looks withenergy efficiency, Ecovector® Lowincludes built-in thermostatic control.Heat outputs up to 3.5kW (12100Btu/h).

Space Saver - ElectricPlinth heaters p45

The Smith’s Space Saver SS80 sits neatlyin plinths just 8cm deep, common inScandinavian-style kitchens to createextra space for more cupboards,worktops, appliances or instead ofunderfloor heating.

www.SmithsEP.co.uk/domestic

Page 31: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

31

Sum

mar

y of

pro

duct

ran

ges

- Dom

esti

c ap

plic

atio

ns

www.SmithsEP.co.uk/domestic

Applications chartDomesticRoom Best 444 Better 44 Good 4Kitchen/Utility Room Space Saver Plinth Ecovector® High Ecovector® Low Sterling High Eco-Powerad® Low

Bathroom/En-suite Space Saver Plinth Ecovector® High Sterling HighCloakroom Ecovector® High Sureline® Ecovector® Low Sterling High Eco-Powerad® Low Hall Ecovector® Vertical Ecovector® Low Sureline®

Eco-Powerad® LowLanding Ecovector® Low Ecovector® Vertical Eco-Powerad® Low Living Room/Dining Room Ecovector® Low Ecovector® Vertical Spacemaker Recessed Eco-Powerad® LowFireplace Hydroflame® Conservatory Ecovector® High Ecovector® Vertical Sterling HighBedroom Ecovector® Low Sureline® Ecovector® Vertical Eco-Powerad® LowHome Office/Study Ecovector® High Ecovector® Low Ecovector® Vertical Sterling High Eco-Powerad® Low

CommercialRoom Best 444 Better 44 Good 4Showroom Caspian UV/UVC/FF Skyline® Ceiling High Caspian Low Caspian High Ecovector® Sureline®

Caspian Skyline®

Shop Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Caspian Skyline® Sterling High

Entrance Hall/Corridor Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Sureline®

Sterling High Spacemaker Recessed

Reception Ecovector® Low Ecovector® Vertical Ecovector® High Eco-Powerad® Low Sureline® Sterling High Caspian High

Waiting Room Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Caspian Low Sterling High

Meeting Room/Hall/Club Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Caspian Skyline® Sterling High

Changing Room Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Caspian Skyline® Sterling High

Public House Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Caspian Skyline® Sterling High

Place of Worship Caspian UV/UVC/FF/EXT Ecovector® Low Ecovector® Vertical Caspian High Eco-Powerad® Low Sureline®

Caspian Low

School, Nursery Caspian UV/UVC/FF/EXT Skyline® Ceiling Ecovector® High Caspian LST Caspian High Sterling High Caspian Skyline® Sterling High

Care Home, Hospital Caspian UV/UVC/FF Skyline® Ceiling Ecovector® High Caspian Universal LST Caspian High Sterling High Caspian Skyline® Sterling High Sureline®

Library Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Low Caspian High Ecovector® High Eco-Powerad® Low Caspian Skyline® Sterling High

Page 32: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

Sound Levels Normal Boost Casing Model (dBA) (dBA) Colour Fan-Only

Hydronic

Ecovector HL 1000 32 40 White •

Ecovector HL 2300 34 50 White •

Ecovector HL 2900 37 51 White •

Ecovector HL 4000 39 52 White •

Sterling 1000-240V 32 40 White •

Hydronic Low Voltage

Ecovector HL 1000-12V 32 39 White •

Sterling 1000-12V 32 39 White •

32

The Ecovector® and Sterling Hydronic and Hydronic Low Voltage fan convectors provideeffective and dependable heating for both large and small rooms, fitted unobtrusivelyabove head height. They work particularly well in conservatories and areas wherelower wall space is limited. Supplied as standard in white but casing can be supplied inany colour.

Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

Ecovector HL 1000 1.0 (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400)

Ecovector HL 2300 2.3 (7850) 3.1 (10500) 2.1 (7000) 2.8 (9400) 1.9 (6400) 2.5 (8500) 1.7 (5700) 2.1 (7300)

Ecovector HL 2900 2.9 (10000) 4.2 (14500) 2.7 (9200) 4.0 (13500) 2.5 (8500) 3.5 (12000) 2.3 (7700) 3.2 (11000)

Ecovector HL 4000 4.0 (13500) 5.3 (18000) 3.7 (12500) 4.8 (16500) 3.3 (11300) 4.4 (15100) 3.0 (10400) 4.1 (13900)

Sterling 1000-240V 1.0 (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400)

Hydronic Low Voltage

Ecovector HL 1000-12V 1.0 (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400)

Sterling 1000-12V 1.0 (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400)

Ecovector®

/Sterling High

2. Domestic fan convectors

Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

Ecovector HL 1000 0.7 (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000)

Ecovector HL 2300 1.4 (4800) 1.9 (6600) 1.4 (4700) 1.8 (6300) 1.2 (4100) 1.6 (5500) 1.1 (3600) 1.4 (4800)

Ecovector HL 2900 2.1 (7200) 2.9 (9800) 1.9 (6600) 2.6 (8900) 1.6 (5400) 2.3 (7800) 1.4 (4750) 2.0 (6800)

Ecovector HL 4000 2.7 (9100) 3.4 (11500) 2.4 (8200) 3.2 (10900) 2.1 (7150) 2.8 (9600) 1.8 (6300) 2.5 (8400)

Sterling 1000-240V 0.7 (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000)

Hydronic Low Voltage

Ecovector HL 1000-12V 0.7 (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000)

Sterling 1000-12V 0.7 (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000)

Heat Output at 40ºC Normal Boost Model kW (Btu/h) kW (Btu/h)

Hydronic

Ecovector HL 1000 0.4 (1350) 0.5 (1800)

Ecovector HL 2300 0.9 (3000) 1.2 (4000)

Ecovector HL 2900 1.2 (4000) 1.7 (5700)

Ecovector HL 4000 1.6 (5300) 2.1 (7000)

Sterling 1000-240V 0.4 (1350) 0.5 (1800)

Hydronic Low Voltage

Ecovector HL 1000-12V 0.4 (1350) 0.5 (1800)

Sterling 1000-12V 0.4 (1350) 0.5 (1800)

www.SmithsEP.co.uk/domestic

Room SizeGuide* (m3)

29

66

-

-

29

33

25

25

Room SizeGuide* (m3)

29

66

-

-

29

33

25

25

Room SizeGuide* (m3)

29

66

-

-

29

33

25

25

*Room sizes given in cubic metres for general guidance only based on normal heat output (80ºC) for domestic applications - always calculate heat losses. Heat outputs tested inaccordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Fan-only option operational only when central heating system is switched off. Soundlevels measured at 1.5m.

Room SizeGuide* (m3)

29

66

-

-

29

33

25

25

2.D

omes

tic

fan

conv

ecto

rs

Page 33: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

33

Ecovector®/Sterling HighFinish

Front casing: zinc-coated steel. Polyester, powder-coated: texturedwhite BS 4800 00A01 18% gloss

Side panels: polymer eggshell white

Installation

• Maximum installation height 2.1m (6’11”) to underside

• No top or side clearance required

• Unit must be earthed (except model 1000-12V)

• Suitable for two-pipe central heating systems

• Pattress box not supplied for transformer (model 1000-12V)

Commissioning

Check water is hot enough to activate the low temperature cut-outthermostat. The inclusion of an automatic air vent at the highestpoint is recommended to avoid possible air locks

Controls

Two rocker switches - normal/off/boost, heating/fan-only

Low temperature cut out thermostat, set to energise fan atapproximately 35°C

Accessory

Wall-mounted room thermostat

Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Model Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres)

Hydronic

Ecovector HL 1000 15mm 1.5m n/a n/a n/a 3A 20 25 0.28

Ecovector HL 2300 15mm 1.5m n/a n/a n/a 3A 20 32 0.32

Ecovector HL 2900 15mm 1.5m n/a n/a n/a 3A 33 50 0.52

Ecovector HL 4000 22mm 1.5m n/a n/a n/a 3A 40 60 1.04

Sterling 1000-240V 15mm 1.5m n/a n/a n/a 3A 20 25 0.28

Hydronic Low Voltage

Ecovector HL 1000-12V 15mm 0.45m • n/a n/a 3A 20 25 0.28

Sterling 1000-12V 15mm 0.45m • n/a n/a 3A 20 25 0.28

Ecovector® HL 1000, 1000-12V, 2300, 2900 Ecovector® HL 4000

276

Electrical supplyin this side

124

37

96

112

A

8825

80Pipe Centres

A

Pipe Centres690

Electrical supplyin this side

124

100

78

35

112276

Model A 1000 470 1000-12V 470 2300 781 2900 1062 4000 1412

www.SmithsEP.co.uk/domestic

2. Domestic fan convectors

Sterling Hydronic 1000-240V, 1000-12V

276

Electrical supplyin this side

124

37

96

112

540

5325

80Pipe Centres

All dimensions in mm

All dimensions in mm

2.D

omes

tic

fan

conv

ecto

rs

See Glossary on page 46 for further information on Accessories

Page 34: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

2. Domestic fan convectors2.

Dom

esti

c fa

n co

nvec

tors

34

Ecovector®

LowEcovector® Low Level fan convectors provide warmth from the floor upwards and aremore energy efficient and effective than radiators. The Ecovector® can heat up a roommore quickly than radiators, thereby reducing the amount of time your boiler or heatpump is running - making it extremely efficient and cost effective. Ideal for new andexisting developments, due to ease of installation, the Ecovector® is available in a range ofmodels to suit varying room sizes and heat output requirements. Supplied as standard inwhite but casing can be supplied in any colour.

Total Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Model Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres)

Hydronic

Ecovector LL 1200 15mm 1.5m n/a n/a n/a 3A 17 21 0.29

Ecovector LL 2000 15mm 1.5m n/a n/a n/a 3A 26 55 0.58

Ecovector LL 2800 15mm 1.5m n/a n/a n/a 3A 43 76 0.83

Ecovector® Low LevelFinish

Front casing: zinc coated steel. Polyester, powder-coated:textured white BS 4800 00A01 18% gloss

Side panels: polymer eggshell white

Installation

• Mounting bracket supplied

• Unit must be earthed

• Suitable for two-pipe central heating systems

• Minimum height above floor level 150mm

• Maximum height above floor level 500mm

Commissioning

Check water is hot enough to activate the selectable lowtemperature cut-out thermostat

Controls

Rocker switch - normal/off/boost

Built-in room thermostat

Low temperature cut-out thermostat set to energise fan atapproximately 35°C

Electrical supplyin this sidePipe centres

A 115

6833

36

98

37

Ø15445

150

All dimensions in mm

Model A LL 1200 635 LL 2000 1025 LL 2800 1385

Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

Ecovector LL 1200 0.8 (2600) 1.0 (3450) 0.7 (2250) 0.8 (2900) 0.6 (1900) 0.7 (2500) 0.5 (1600) 0.6 (2050)

Ecovector LL 2000 1.3 (4550) 1.7 (5900) 1.2 (4050) 1.6 (5300) 1.0 (3500) 1.3 (4400) 0.9 (3050) 1.1 (3700)

Ecovector LL 2800 1.9 (6400) 2.4 (8100) 1.5 (5200) 2.1 (7200) 1.3 (4500) 1.8 (6100) 1.2 (4000) 1.5 (5200)

Heat Output at 40ºC Normal Boost Model kW (Btu/h) kW (Btu/h)

Hydronic

Ecovector LL 1200 0.4 (1250) 0.5 (1600)

Ecovector LL 2000 0.7 (2500) 0.8 (2900)

Ecovector LL 2800 1.0 (3250) 1.2 (4200)

www.SmithsEP.co.uk/domestic

Room SizeGuide* (m3)

34

57

80

Room SizeGuide* (m3)

34

57

80

Room SizeGuide* (m3)

34

57

80

Room SizeGuide* (m3)

34

57

80

*Room sizes given in cubic metres for general guidance only based on normal heat output (80ºC) for domestic applications - always calculate heat losses. Heat outputs tested in accordancewith BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Sound levels measured at 1.5m.

See Glossary on page 46 for further information on Accessories

Sound Levels Normal Boost Casing Model (dBA) (dBA) Colour Fan-Only

Hydronic

Ecovector LL 1200 32 38 White n/a

Ecovector LL 2000 35 40 White n/a

Ecovector LL 2800 37 42 White n/a

Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

Ecovector LL 1200 1.2 (4000) 1.6 (5400) 1.1 (3700) 1.4 (4800) 1.0 (3350) 1.3 (4300) 0.9 (3000) 1.1 (3900)

Ecovector LL 2000 2.0 (6900) 2.6 (8900) 1.9 (6400) 2.4 (8200) 1.6 (5500) 2.2 (7600) 1.5 (5000) 1.9 (6600)

Ecovector LL 2800 2.8 (9700) 3.5 (12100) 2.6 (9000) 3.2 (11050) 2.3 (8000) 2.9 (10000) 2.0 (6800) 2.6 (9000)

Page 35: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

35 www.SmithsEP.co.uk/domestic

2. Domestic fan convectors

2.D

omes

tic

fan

conv

ecto

rs

Eco-Powerad®

The Eco-Powerad® is the fan convector of the future - energy efficient, responsive andsuitable for installation within most wet central heating systems, driven by either boilers orlow temperature renewable technology. Compact, with smooth lines to achieve visualsimplicity, the Eco-Powerad® also features low surface temperature casing for completesafety and possesses a very low operating sound - between 28 and 32 decibels. Suppliedas standard in white but can be supplied in any colour.

Model A Eco-Powerad 500 485 Eco-Powerad 1000 845 Eco-Powerad 1500 1210 Eco-Powerad 2000 1570

Eco-Powerad®

Finish

Front casing: zinc coated steel Polyester, powder-coated: white RAL 9010

Installation

• Mounting bracket supplied

• Unit must be earthed

• Suitable for two-pipe central heating systems

• Minimum height above floor level 150mm

• Maximum height above floor level 500mm

Commissioning

Check water is hot enough to activate the low temperature cut-out thermostat. Ensure system is balanced for evenheat distribution

Controls

Low temperature cut-out thermostat, set to energise fan atapproximately 35°C

Suitable for thermostatic radiator valves (TRV) - not supplied

Rocker switch - normal/low

Accessory

Wall-mounted room thermostat.

A

All dimensions in mm

26 26

400332

95

150 minElectrical supplyin this side

38

Model Sound Casing Flow & Mains Flexible Isolating Fused Total Power Water Levels* Colour Return Cable Transformer Hoses Valves Spur Consumption Capacity (dBA) Connections (Watts) (Litres)

Hydronic

Eco-Powerad 500 28 White 15mm 2m n/a n/a n/a 3A 15 0.17

Eco-Powerad 1000 30 White 15mm 2m n/a n/a n/a 3A 18 0.28

Eco-Powerad 1500 31 White 15mm 2m n/a n/a n/a 3A 33 0.44

Eco-Powerad 2000 32 White 15mm 2m n/a n/a n/a 3A 36 0.55

*Measured at 1.5m.

Heat Heat Heat Heat Heat Heat Heat Heat Heat Output Output Output Output Output Output Output Output Output

at 80ºC at 75ºC at 70ºC at 65ºC at 60ºC at 55ºC at 50ºC at 45ºC at 40ºCModel kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

Eco-Powerad 500 0.9 (3100) 0.8 (2900) 0.8 (2750) 0.7 (2400) 0.6 (2050) 0.5 (1875) 0.5 (1700) 0.4 (1375) 0.3 (1050)

Eco-Powerad 1000 2.4 (8200) 2.1 (7150) 1.8 (6100) 1.6 (5450) 1.4 (4775) 1.2 (4100) 1.0 (3400) 0.8 (2725) 0.7 (2400)

Eco-Powerad 1500 2.6 (8900 2.4 (8200) 2.2 (7500) 2.0 (6825) 1.9 (6475) 1.7 (5800) 1.5 (5100) 1.2 (4100) 0.9 (3100)

Eco-Powerad 2000 3.9 (13200) 3.5 (11950) 3.2 (10900) 2.8 (9550) 2.5 (8525) 2.2 (7675) 2.0 (6800) 1.7 (5800) 1.3 (4600)

Wall-mounted room thermostat

Room SizeGuide* (m3)

14

29

43

57

*Room sizes given in cubic metres for general guidance only based on normal heat output (50ºC) for domestic applications - always calculate heat losses. Heat outputs tested inaccordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate.

At inlet water temperatures of 75°C and below, all Eco-Powerad models are classified as LST (low surface temperature) appliances.

See Glossary on page 46 for further information on Accessories

Page 36: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

36

Ecovector®

VerticalEcovector® Vertical is ideal for hallways, alcoves and other places where space is limited.Ecovector® can heat up a room more quickly than radiators, thereby reducing the amountof time your boiler or heat pump is running - making it extremely efficient and costeffective. Ideal for new and existing housing developments, due to ease of installation.Supplied as standard in white but can be supplied in any colour.

Ecovector® Vertical

Finish

Front casing and side panels: zinc-coated steel. Polyester,powder-coated: textured white BS 4800 00A01 18% gloss

Installation

• Mounting bracket supplied

• Unit must be earthed

• Suitable for two-pipe central heating systems

• Minimum height above floor level 150mm, maximumheight above floor level 500mm

Commissioning

Check water is hot enough to activate the selectable lowtemperature cut-out thermostat

Controls

Rocker switch - normal/off/boost

Low temperature cut-out thermostat set to energise fan atapproximately 35°C

Wireless wall mounted thermostat included with this product All dimensions in mm

Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Model Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres)

Hydronic

Ecovector® VE 2500 15mm 1.5m n/a n/a n/a 3A 28 36 0.75

Sound Levels Normal Boost Casing Model (dBA) (dBA) Colour Fan-Only

Hydronic

Ecovector VE 2500 36 39 White n/a

Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

Ecovector VE 2500 2.5 (8500) 2.6 (8800) 2.3 (7800) 2.4 (8200) 2.0 (6900) 2.1 (7300) 1.9 (6400) 2.0 (6700)

Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

Ecovector VE 2500 1.7 (5800) 1.8 (6000) 1.5 (5100) 1.5 (5200) 1.3 (4400) 1.3 (4600) 1.1 (3800) 1.1 (3900)

Heat Output at 40ºC Normal Boost Model kW (Btu/h) kW (Btu/h)

Hydronic

Ecovector VE 2500 0.9 (3200) 1.0 (3400)

*Room sizes given in cubic metres for general guidance only based on normal heat output (80ºC) for domestic applications - always calculate heat losses. Heat outputs tested inaccordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Fan-only option operational only when central heating system is switched off.

www.SmithsEP.co.uk/domestic

Room SizeGuide* (m3)

71

Room SizeGuide* (m3)

71

Room SizeGuide* (m3)

71

Room SizeGuide* (m3)

71

330160

770

100 Min28

5438

22

16

Electrical Supplyin this side

PipeCtrs

See Glossary on page 46 for further information on Accessories

2. Domestic fan convectors2.

Dom

esti

c fa

n co

nvec

tors

Page 37: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

37 www.SmithsEP.co.uk/domestic

2. Domestic fan convectors

2.D

omes

tic

fan

conv

ecto

rs

SpacemakerPerfect for places in the home where space is particularly limited. A fan convector thatinstalls flush with the floor, providing efficient and effective heat at low level. Ideal forspaces such as entrance halls, lobbies, circulation areas and applications where wall spaceis limited.

Spacemaker SST8

Finish

Anodised aluminium grille with removable centre section.

Installation

• Installs between floor joists or purpose made trenches inconcrete floors

• Air intake and discharge through grille

• Unit must be earthed

• Suitable for two-pipe central heating systems only

Commissioning

Check water temperature is hot enough to activate lowtemperature cut-out (LTC). Vent screw accessible throughgrille

Controls

Rocker switch - normal/off/boost, below grille

Low temperature cut-out thermostat set to energise fan atapprox. 35°C

Accessories

Wall-mounted room thermostat

194

397

298

236

35020

161

Air flow pattern

Floor cut out size:357 x 254

35Pipe

Centres

Spacemaker SST8

All dimensions in mm

Wall-mounted room thermostat

Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

Spacemaker SST8 1.6 (5500) 2.2 (7500) 1.5 (5000) 2.1 (7100) 1.3 (4400) 1.8 (6100) 1.2 (4100) 1.7 (5800)

Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Model Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres)

Hydronic

Spacemaker SST8 15mm 1.5m n/a n/a n/a 3A 20 30 0.27

Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

Spacemaker SST8 1.1 (3700) 1.5 (5100) 0.9 (3200) 1.3 (4500) 0.8 (2800) 1.2 (4000) 0.7 (2400) 1.0 (3400)

Sound Levels Normal Boost Model (dBA) (dBA) Casing Colour Fan-Only

Hydronic

Spacemaker SST8 32 39 Anodised n/a aluminium grille

Heat Output at 40ºC Normal Boost Model kW (Btu/h) kW (Btu/h)

Hydronic

Spacemaker SST8 0.6 (1900) 0.9 (3000)

Room SizeGuide* (m3)

46

Room SizeGuide* (m3)

46

Room SizeGuide* (m3)

46

*Room sizes given in cubic metres for general guidance only based on normal heat output (80ºC) for domestic applications - always calculate heat losses. Heat outputs tested inaccordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Sound levels measured at 1.5m.

Room SizeGuide* (m3)

46

See Glossary on page 46 for further information on Accessories

Page 38: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

Hydroflame®

Flame-effect fan convectors that run off the central heating system, but with all the visualappeal of a real fire – a beautiful feature in any room. Efficient, cost effective and totallysafe, with no harmful discharges. Ideal for children and the elderly because there are noflames or hot surfaces. Available in Inset or Freestanding and a choice of eyecatchingdesigns. Hydroflame Classic and Elite can be supplied with an attractive choice of trimsand complementary fireplace surrounds.

38 www.SmithsEP.co.uk/domestic

Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

Inset (Classic & Elite) 1.5 (5100) 2.0 (6800) 1.3 (4600) 1.8 (6200) 1.2 (4100) 1.6 (5500) 1.1 (3700) 1.5 (5100)

Freestanding (Classic & Elite) 1.5 (5100) 2.0 (6800) 1.3 (4600) 1.8 (6200) 1.2 (4100) 1.6 (5500) 1.1 (3700) 1.5 (5100)

Hydronic/Electronic (Dual)

Inset Dual (Classic & Elite) 1.5 (5100) 2.0 (6800) 1.3 (4600) 1.8 (6200) 1.2 (4100) 1.6 (5500) 1.1 (3700) 1.5 (5100) 1.5 - 1.5 - 1.5 -

Freestanding Dual (Classic & Elite) 1.5 (5100) 2.0 (6800) 1.3 (4600) 1.8 (6200) 1.2 (4100) 1.6 (5500) 1.1 (3700) 1.5 (5100) 1.5 - 1.5 - 1.5 - 1.5 -

In hydronic mode In electric mode

Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

Inset (Classic & Elite) 0.9 (3200) 1.3 (4500) 0.8 (2600) 1.1 (3900) 0.7 (2300) 1.0 (3500) 0.6 (2000) 0.9 (3000))

Freestanding (Classic & Elite) 0.9 (3200) 1.3 (4500) 0.8 (2600) 1.1 (3900) 0.7 (2300) 1.0 (3500) 0.6 (2000) 0.9 (3000)

Hydronic/Electronic (Dual)

Inset Dual (Classic & Elite) 0.9 (3200) 1.3 (4500) 0.8 (2600) 1.1 (3900) 0.7 (2300) 1.0 (3500) 0.6 (2000) 0.9 (3000) 1.5 - 1.5 - 1.5 -

Freestanding Dual (Classic & Elite) 0.9 (3200) 1.3 (4500) 0.8 (2600) 1.1 (3900) 0.7 (2300) 1.0 (3500) 0.6 (2000) 0.9 (3000) 1.5 - 1.5 - 1.5 - 1.5 -

Heat Output at 40ºC Normal Boost Model kW (Btu/h) kW (Btu/h)

Hydronic

Inset (Classic & Elite) 0.5 (1700) 0.8 (2600)

Freestanding (Classic & Elite) 0.5 (1700) 0.8 (2600)

Hydronic/Electronic (Dual)

Inset Dual (Classic & Elite) 0.5 (1700) 0.8 (2600) 1.5 -

Freestanding Dual (Classic & Elite) 0.5 (1700) 0.8 (2600) 1.5 -

Sound Levels Normal Boost Flame-Effect Model (dBA) (dBA) Trim Colour Only

Hydronic

Inset (Classic & Elite) 27 43 Brass or Chrome •

Freestanding (Classic & Elite) 27 43 Brass or Chrome •

Hydronic/Electronic (Dual) Inset Dual (Classic & Elite) 27 43 Brass or Chrome • Freestanding Dual (Classic & Elite) 27 43 Brass or Chrome •

Room SizeGuide* (m3)

43

43

29

43

43

Room SizeGuide* (m3)

43

43

29

43

43

Room SizeGuide* (m3)

43

43

29

43

43

*Room sizes given in cubic metres for general guidance only based on normal heat output (80ºC) for domestic applications - always calculate heat losses. Heat outputs tested inaccordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Fan-only option operational only when central heating system is switched off. Dualmodels include an electric element which in electric heating mode will emit 1.5kW of heat. Sound levels measured at 1.5m.

Room SizeGuide* (m3)

43

43

29

4343

3. Flame-effect fan convectors3.

Flam

e-ef

fect

fan

con

vect

ors

Page 39: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

39 www.SmithsEP.co.uk/domestic

Hydroflame® design options

Model Type Trim Colour

Brass Chrome

Hydroflame Elite

Inset • •

Inset Dual • •

Freestanding • •

Freestanding Dual • •

Hydroflame Classic

Inset • •

Inset Dual • •

Freestanding • •

Freestanding Dual • •

Hydroflame® Classic & EliteConnects to and runs from your central heating system(hydronic mode)Installation• Inset model designed for a recess 400mm x 550mm high

• Unit must be earthed

• Suitable for two-pipe central heating systems only

• Surface temperature of the casing complies with thesafety requirement DHSS DN4

CommissioningCheck water temperature is hot enough to activate lowtemperature cut-out device (LTC) ControlsTwo rocker switches - normal/off/boost, flame-effecton/flame-effect off

Variable low temperature cut-out device factory set toenergise fan at approximately 40°C. Set temperature can beadjusted higher or lower during installation

Built-in room thermostat

Hydroflame® Dual Classic & EliteConnects to and runs from your central heating system (hydronic mode), but also includes anelectric heating element for use when the central heating is switched offInstallation• Inset Dual model designed for a recess 400mm x 550mm high

• Unit must be earthed

• Suitable for two-pipe central heating systems only

• Surface temperature of the casing complies with the safety requirement DHSS DN4CommissioningCheck water temperature is hot enough to activate low temperature cut-out device (LTC)ControlsThree rocker switches - normal/off/boost, hydronic/electric, flame-effect on/flame-effect off

Variable low temperature cut-out device factory set to energise fan at approximately 40°C Set temperature can be adjusted higher or lower during installation

Built-in room thermostat

Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Model Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres)

Hydronic

Inset (Classic & Elite) 15mm 2.0m n/a • • 3A 29 36 0.36

Freestanding (Classic & Elite) 15mm 2.0m n/a • • 3A 29 36 0.36

Hydronic/Electric (Dual)

Inset Dual (Classic & Elite) 15mm 2.0m n/a • • 10A 29 36 0.36 1518 1518

Freestanding Dual (Classic & Elite) 15mm 2.0m n/a • • 10A 29 36 0.36 1518 1518

In hydronic mode In electric mode

Inset & Inset Dual

35

15

12

45

310

210

460

355160

545580

160Pipes Ø15

Freestanding & Freestanding Dual

50

12

45

310

255

650

35

85 568

Pipes Ø15

1009

225

1190 300

715

1220 410

44

Fireplace Surround

All dimensions in mm

Freestanding Classic Chrome Freestanding Classic Brass Freestanding Elite Brass Freestanding Elite Chrome

Cream with cream back plate and hearth

Yew with black back plate and hearth

Yew with cream back plate and hearth

Antique Oak with black back plate and oak hearth

Antique Oak with cream back plate and oak hearth

3.Fl

ame-

effe

ct f

an c

onve

ctor

s

Page 40: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

3. Flame-effect fan convectors

40 www.SmithsEP.co.uk/domestic

Features & benefitsCompletely safeHydroflame is safe because it uses water from thecentral heating system to produce heat.

• No independent gas supply needed

• No flue gases are produced – so a flue and COdetector are not required

• No live flames, hot coals or elements

• Low surface temperatures

• No special ventilation required

• Hidden fixings for extra security

• No minimum room size

A beautiful focal feature in the room Stylish and attractive appearance characterisesHydroflame’s innovative design.

• Fit on any internal or external wall surface, intoa fireplace opening, or in front of a fireplacesurround

• Can be used simply to replace an existingpanel radiator

• Can show a comforting flame-effect with orwithout the heating being switched on

Simple controlsOperating Hydroflame could not be simpler.

• Clearly labelled, easy action rocker switches

• Easy to use by elderly or infirm people

Minimal running costsHydroflame has a unique method of operationthat brings significant savings on running costs.

• Operates as part of the central heating system,where average usage on normal heat outputwill add less than £10.00 a year to annualheating bills (excluding any separate use of theelectric heating element on Dual models). Seetable of running costs.

Environmentally friendly

Hydroflame has less of an impact on theenvironment than electric, gas or open firealternatives.

• No harmful gases expelled to the atmosphere

• Automatic response to water temperature,providing the correct amount of heat whenneeded

• Thermostatically controlled

• Slower fan speed for flame-effect only reducesenergy consumption

• Energy saving light bulb

Easy to installHydroflame is economical and straightforward toinstall

• No gas supply or flue required – fix to any wall,internal and external

• No chimney or flue liners required

• Inset models fit standard fireplace openings –no need for a replacement surround

• Flexible hoses, isolation valves and pre-wiredelectric cable supplied as standard

• Connects to standard central heating pipe work

For full installation instructions refer to theHydroflame Installation & User Guide, which isavailable on request; or download it fromwww.smiths-env.com

Low maintenanceCost effective and convenient.

• No need for annual servicing or safety checks –so no access to the property is required

• Easy to change the lamp

• Easy for homeowner to clean the filter system

Very low water contentEach Hydroflame has a very low water content of0.36 litres, around 5% of the water content of anequivalent output steel panel radiator.

Heat exchanger

Lamp

Flame-effect

Plumbedinto centralheatingsystem

Coals

Cool air

Warm air

How Hydroflame® works

Hot water from the central heating system passes through aheat exchanger and transfers its heat to the aluminium fins.

Cooler air is drawn in at floor level and used to create theflame-effect. The air is heated as it passes over the heatexchanger, a patented process that creates a realistic flame-effect, and then expelled gently back into the room.

This gives a more even temperature and will heat a room inmuch less time than a traditional panel radiator.

The fan will not come into operation until the central heatingsystem water passing through the heat exchanger reaches 40°C(or the temperature set by the installer). This ensures that coolerair is not circulated at start up and allows Hydroflame to switchon and off automatically in conjunction with the central heatingsystem.

Flame-effect fan convectors are energy efficient and in thehome will add less than £10.00* to your annual heating bill.

Dual models include an electric heating element – ideal in springand summer when you may need a quick warm up but thecentral heating system is switched off.

Note: *based on electricity charged at 15p/kWh.

AssumptionsElectricity charged at 15p per kWh.Hydroflame operating on normal - 1.5kW heat output.Excludes use of electric heating element.

Annual Running Costs Usage (£) (Hours) 11W Bulb 29W Fan Annual Total

1100 1.82 4.79 6.60

1300 2.15 5.65 7.80

1700 2.81 7.39 10.20

2500 4.13 10.87 15.00

Hydroflame® running costs(Models fitted with 11W energy-saving long-life bulb)

3.Fl

ame-

effe

ct f

an c

onve

ctor

s

Page 41: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

41 www.SmithsEP.co.uk/domestic

4. Natural Convectors (perimeter heating)

Sureline®

The Sureline® provides gentle, discreet and efficient low-level warmth and is the idealheating solution for areas where wall space is limited - rooms such as loft conversions andnew-build. Simple to install along the skirting in any room, Sureline® is an efficient naturalconvector that provides discreet heating. Supplied as standard in white but casing can besupplied in any colour.

Sureline®

Finish

Outer casing 0.7mm zinc coated steel. Polyester, powder-coated. Paint specification: textured white BS 4800 00A0118% gloss. Each length includes casing, element, backplateand joining strip. Casing only includes casing, backplate andjoining strip

Installation

• Minimum clearance above floor 50mm

• Flow and return connections 22mm copper

• Designed for system pressures up to 10 bar

• Suitable for two-pipe central heating systems only

Attachments

Casing only (1000mm)

LH valve box/end cap kit RH valve box/end cap kit

Centre valve cover 90° internal cover

90° external cover 135° internal cover

135° external cover Finger guard 500 (500mm)

Finger guard 1000 (1000mm) Element (1000mm)

Customised requirements

We are able to offer casings painted in any colour. Price andavailability will be confirmed at the time of order

*We recommended the use of finger guards in installationswhere infants have access to the underside of Sureline.

17

Length A

Lengthincludes casing,

element,backplate

and joiningstrip

1738

Backplate

17968

31

74.5

Frontcasing

Element

76 75

180

152172

180

75

Centre valve cover

Joining strip

25mm overlapon coverMinimum

overlap20mm

LH and RH valvebox/end

stop kit (RHshown)

Body with openbottom75

180

126.5

128.5

180 180

74

180

75.5

51

51 75.5

500 or 1000

Plan view Plan view Plan view

90° External corner

Finger guard

90° Internal corner 135° External corner135° Internal corner

Plan view

75.5 125

75.5 125

75.5

81.5

75.5

81.5

75.5

92.5

75.5

60.5

92.5

All dimensions in mm

180

Heat OutputFlow Rate Btu/h/m @ average water temperature W/m @ average water temperatureL/h (G/h) 50°C 55°C 60°C 65°C 70°C 75°C 80°C 50°C 55°C 60°C 65°C 70°C 75°C 80°C

Two supplies - Parallel 920 (200) 1310 1570 1820 2070 2300 2560 2810 380 460 530 610 670 750 820

Bottom supply - Top return 920 (200) 1030 1250 1460 1710 1920 2140 2330 300 370 430 500 560 630 680

All heat outputs relate to 1 metre length

Model Length A (mm)

Sureline 2000 2000 Sureline 1500 1500 Sureline 1000 1000 Sureline 1000C* 1000 Sureline 500 500* casing only

Heating element

Sureline with TRV

See Glossary on page 46 for further information on Accessories

4.N

atur

al C

onve

ctor

s (p

erim

eter

hea

ting)

Page 42: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

42 www.SmithsEP.co.uk/domestic

5. Plinth Heaters - Hydronic

Space SaverA highly energy efficient fan convector that fits neatly into the plinth of a kitchen unit.Space Saver eliminates the need for conventional radiators. And, as its name implies, thisbrings considerable space saving benefits - more room for extra storage units, more worksurfaces, more space for kitchen appliances.

Space Saver is used predominantly for domestic applications where the ingenious plinth-mounting feature makes it ideal for heating kitchens and utility rooms. Plinth mounting alsomakes Space Saver ideal for certain non-domestic applications such as reception areas,changing rooms, libraries, etc.

*Room sizes given in cubic metres for general guidance only based on normal heat output (80ºC) for domestic applications - always calculate heat losses. Heat outputs tested inaccordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Fan-only option operational only when central heating system is switched off. Dualmodels include an electric element which in electric heating mode will emit 1kW of heat.

Before After

Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

SS80 0.8 (2900) 1.1 (3600) 0.8 (2700) 0.9 (3200) 0.7 (2500) 0.8 (2800) 0.6 (2200) 0.7 (2500)

SS3 (Improved heat output) 1.1 (3800) 1.4 (4800) 1.0 (3400) 1.3 (4400) 0.9 (3100) 1.2 (4100) 0.8 (2700) 1.1 (3800)

SS5 1.3 (4400) 1.7 (5800) 1.2 (4100) 1.6 (5500) 1.1 (3800) 1.4 (4700) 1.0 (3400) 1.3 (4400)

SS7 1.6 (5500) 1.9 (6500) 1.4 (4800) 1.8 (6100) 1.3 (4400) 1.6 (5500) 1.2 (4100) 1.5 (5000)

SS9 2.2 (7500) 2.4 (8200) 2.1 (7000) 2.2 (7500) 1.8 (6300) 2.0 (6900) 1.7 (5900) 1.8 (6300)

Hydronic Low Voltage

SS5 12V 1.3 (4400) 1.7 (5800) 1.2 (4100) 1.6 (5500) 1.1 (3800 1.4 (4700) 1.0 (3400) 1.3 (4400)

Hydronic/Electric (Dual)

SS5 Dual 1.3 (4400) 1.7 (5800) 1.2 (4100) 1.6 (5500) 1.1 (3800 1.4 (4700) 1.0 (3400) 1.3 (4400)

1.0 – 1.0 – 1.0 – 1.0 –

Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)

Hydronic

SS80 0.6 (1900) 0.7 (2300) 0.5 (1700) 0.6 (2000) 0.4 (1400) 0.5 (1700) 0.35 (1200) 0.4 (1400)

SS3 (Improved heat output) 0.7 (2400) 1.0 (3400) 0.6 (2000) 0.9 (3100) 0.5 (1700) 0.8 (2700) 0.4 (1400) 0.7 (2400)

SS5 0.9 (3100) 1.1 (3800) 0.8 (2700) 1.0 (3400) 0.7 (2400) 0.9 (3100) 0.6 (2000) 0.8 (2700)

SS7 1.1 (3800) 1.3 (4500 1.0 (3400) 1.2 (4000) 0.9 (3100) 1.0 (3400) 0.8 (2700) 0.9 (3000)

SS9 1.5 (5200) 1.7 (5700) 1.3 (4500) 1.5 (5000 1.1 (3900) 1.3 (4300) 0.9 (3200) 1.1 (3700)

Hydronic Low Voltage

SS5 12V 0.9 (3100 1.1 (3800) 0.8 (2700) 1.0 (3400) 0.7 (2400) 0.9 (3100) 0.6 (2000) 0.8 (2700)

Hydronic/Electric (Dual)

SS5 Dual 0.9 (3100 1.1 (3800) 0.8 (2700) 1.0 (3400) 0.7 (2400) 0.9 (3100) 0.6 (2000) 0.8 (2700)

1.0 – 1.0 – 1.0 – 1.0 –

Room SizeGuide* (m3)

24

31

37

46

63

33

37

29

Room SizeGuide* (m3)

24

31

37

46

63

33

37

29

In hydronic mode In electric mode

5.Pl

inth

Hea

ters

- H

ydro

nic

Page 43: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

43 www.SmithsEP.co.uk/domestic

In hydronic mode In electric mode

*Room sizes given in cubic metres for general guidance only based on normalheat output (80ºC) for domestic applications - always calculate heat losses. Heatoutputs tested in accordance with BS4856 using entering water temperatureand 340 l/h (75gph) flow rate. Fan-only option operational only when centralheating system is switched off. Dual models include an electric element which inelectric heating mode will emit 1kW of heat.

Heat Output at 40ºC Normal Boost Model kW (Btu/h) kW (Btu/h)

Hydronic

SS80 0.3 (900) 0.3 (1100)

SS3 (Improved heat output) 0.3 (1000) 0.6 (2000)

SS5 0.5 (1700) 0.7 (2400)

SS7 0.6 (2000) 0.8 (2700)

SS9 0.7 (2500) 0.9 (3000)

Hydronic Low Voltage

SS5 12V 0.5 (1700) 0.7 (2400)

Hydronic/Electric (Dual)

SS5 Dual 0.5 (1700) 0.7 (2400)

1.0 –

Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Model Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres)

Hydronic

SS80 15mm 2.0m n/a • n/a 3A 5 10 0.35

SS3 15mm 2.0m n/a n/a n/a 3A 18 25 0.36

SS5 15mm 2.0m n/a • n/a 3A 18 25 0.36

SS7 15mm 2.0m n/a • n/a 3A 21 30 0.38

SS9 15mm 2.0m n/a • n/a 3A 24 35 0.43

Hydronic Low Voltage

SS5 12V 15mm 0.45m • • n/a 3A 21 30 0.36

Hydronic/Electric (Dual)

SS5 Dual 15mm 2.0m n/a • n/a 5A 18 25 0.36

1009 1013 n/a

In hydronic mode In electric mode

Sound Levels Normal Boost Fascia Grille Model (dBA) (dBA) Finish Fan-Only

Hydronic

SS80 32 40 Stainless Steel •

SS3 26 39 Stainless Steel •

SS5 27 43 Stainless Steel •

SS7 30 44 Stainless Steel •

SS9 41 46 Stainless Steel •

Hydronic Low Voltage

SS5 12V 31 39 Stainless Steel • Hydronic/Electric (Dual)

SS5 Dual 27 43 Stainless Steel •

Sound levels measured at 1.5m.

Room SizeGuide* (m3)

24

31

37

46

63

33

37

29

Room SizeGuide* (m3)

24

31

37

46

63

33

37

5.Pl

inth

Hea

ters

- H

ydro

nic

Page 44: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

44 www.SmithsEP.co.uk/domestic

Space Saver

Fascia Grille Finish

Stainles Steel

InstallationImportant: Correct fascia grille opening must be cut to

allow sufficient air intake • 20mm clearance above unit required • Model secured to plinth by two screws

through fascia grille • Unit must be earthed (not 12 volt SELV) • Suitable for two-pipe central heating

systems only • SS80 supplied with detachable cable • SS80 models have easy fit thermostat facilityAccessories

Wall-mounted room thermostat

SS80: Grilles: brown - RAL 8016, black - RAL 9005, white - RAL9010

All other models: Grilles: brown - RAL 8016, black - RAL 9005,white - RAL 9010, chrome, aluminium, gold

Wall mounted control switch (white) to suit SS3, SS5, SS5/12V,SS7, SS9

Commissioning

Check water temperature is hot enough to activate lowtemperature cut-out thermostat (LTC). Vent screw accessiblethrough fascia grille

Controls

Single rocker switch - low/off/normal

SS80: Low temperature cut-out thermostat set to energise fan atapproximately 35°C

SS5 W/Dual: three rocker switches, heating/off/fan-only,hydronic/electric, normal/boost

Low temperature cut-out thermostat set to energise fan atapproximately 35°C

All other models: two rocker switches -normal/off/boost,heating/fan-only

Low temperature cut-out thermostat set to energise fan atapproximately 35°C

62 Pipe centres

SS9

Smiths

30405

98

91

353

14

170225

600

575

9

100

Smiths

20322 91

89

288

120

14

150

498

475

9

100

65 Pipe centres

Wall-mounted room thermostat

Wall-mounted on/off switch

Brown

White

Gold

Black

Aluminium

Alternative Grille Finishes

Space Saver models are suppliedwith a detachable brushed steelfascia grille. Fascia grilles are alsoavailable in the above colours.

Chrome

Accessories

All dimensions in mm

20322 91

89

62 Pipe centres

288

100135

500

475

9

100

SS5 Dual

SS80

SS3, SS5, SS5 12V, SS7

35696

63

88118

255

3 2520400

74

516550

See Glossary on page 46 for further information on Accessories

5. Plinth Heaters - Hydronic5.

Plin

th H

eate

rs -

Hyd

roni

c

Page 45: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

45 www.SmithsEP.co.uk/domestic

6. Plinth Heaters - Electric

Space Saver

SS2E 290

105 105

91

240

100

500

485

9

All dimensions in mm

The Space Saver offers increased flexibility and space in kitchen design as it enables theremoval of radiators that may be using up valuable wall space. Fitting discreetly into theplinth of a kitchen, the Space Saver provides efficient and effective heat at low level.

Heat Output (kW) Power Consumption (kW) Fused Mains Sound Fascia Grille Fan-Only Model Spur Cable (m) Levels (dBA) Finish**Colour Electric

Space Saver SS3E 1kW/2kW/3kW 1kW/2kW/3kW 13A 2.0 42 Brushed Steel •

Space Saver SS2E 1kW/2kW 1kW/2kW 10A 2.0 42 Brushed Steel •

Space Saver SS80E 0.6kW/1.2kW 0.6kW/1.2kW 10A 23 38 Stainless Steel •

Before After

Additional information

Electric fan-assisted heaters cost around 15p per hour for each 1kW of heat.Hydronic models available.

Wall-mounted room thermostat

SS3E

Sound levels measured at 1.5m.

358 86

226

1219

121

586

600

60 97

Model shown SS2E, other models have different grille andswitch configurations.

SS80E

70 77

304

46078 78212

203 9

Space SaverFascia Grille Finish** - SS2E and SS3E

Zinc coated steel polyester, powder coated - metallic silver(referred to as Brushed Steel)

Fascia Grille Finish - SS80E

Stainless Steel

InstallationImportant: Correct fascia grille opening must be cut to

allow sufficient air intake • SS2E and SS3E - 20mm clearance above unit required SS80E - 10mm clearance above unit required • Model secured to plinth by two screws

through fascia grille • Unit must be earthedAccessories - SS2E

Wall-mounted room thermostat

Grilles: brown - RAL 8016, black - RAL 9005, white - RAL 9010, chrome, aluminium, gold

Alternative grilles for SS2E fit over the supplied grille

Wall-mounted control switch (white) to suit SS2E

Accessories - SS80, SS80E

Wall mounted room thermostat

Grilles: brown - RAL 8016, black - RAL 9005, white - RAL 9010

Controls

Overheat protection: thermal cut-out. Manual resetprocedure: switch power off at unit or mains, wait 5 minutes,switch power onSS2E - three rocker switches On/off, 1kW, 2kWSS3E - Push on/off switch, two rockers switches 1kW, 2kW, 3kWSS80E - three rocker switches On/off, 0.6kW, 1.2kW

See Glossary on page 46 for further information on Accessories

6.Pl

inth

Hea

ters

- El

ectr

ic

Page 46: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

Glossary

Smith’s Accessories

Wall mounted room thermostat - This accessory measures room temperature and switches off theheater when the set temperature is reached. The thermostat connects directly into either the heater’sterminal block or power supply.

Wall mounted control switch - Allows the product to be controlled from a switch mounted on thewall rather than the product. Linking to the heater is made by replacing the existing switch connectionswith the connections on the control switch.

Flexible hoses - Flexible connections are a convenient way of connecting a heater into your system.They will provide an easy to achieve connection from your first-fix pipe work. In addition they willprovide for a level of expansion and contraction in rigid pipe work and mitigating possible sound andvibration transmission.

Adjustable low temperature cut-out (LTC) - This cut out device allows the user to set the watertemperature (between 30ºC and 90ºC) at which the product will start to emit heat. It is more accuratethan the standard fitted LTC (set at 35ºC) and enables more flexible use with both low systemtemperature heat pumps and higher system temperature boilers including biomass that can produce80ºC flow temperatures.

Plinth - The optional plinth creates an attractive floor standing unit and also conceals the pipe workfrom view. This can also be invaluable where it is necessary to prevent contact with heating pipes byvulnerable groups.

External control harness - This accessory allows up to four products to be controlled from a singlepoint. An External Control Harness will be required for each product. Each harness has plug and playconnections.

Proportional Heat Output Controller (PHOC) - This accessory controls the fan speed and hence theheat output of the unit. When the room temperature is below 15ºC the fan speed will run at itsmaximum speed to give fastest heat up time. When the room temperature reaches 15ºC the fan speedand heat output are modulated down progressively as the room temperature increases towards the settemperature.

Thermostat and Auto-Speed control (T1/T2) - This accessory serves two purposes. Firstly, it becomesan integral room thermostat for the unit providing localised control and secondly, the heat output willbe changed according to the temperature in the room. For example, the fan may work on full powerup to 18ºC and above this temperature move to a lower fan speed. Normally the fan speeds used willbe medium and low.

Fresh air inlet spigot - An air inlet spigot is available for 100mm diameter rigid or flexible pipe. Thespigot allows for a portion of air entering the appliance to be fresh air from outside the building. Thisensures an adequate air change rate and improved air quality.

Surface mounting kit - Provides a complete four-sided trim when fitted to a solid ceiling, 135 mm high.

Ceiling tile spacer - Provides semi-recessed profile to match Skyline CT18 when used in ceiling tileframe, 85mm high.

46 www.SmithsEP.co.uk

Glo

ssar

y

Page 47: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems
Page 48: Commercial Heating Domestic Heating - Plinth Heaterssmithsep.co.uk/.../Smiths-Domestic-and-Commercial... · Solutions for domestic & commercial applications Standard heating systems

June 2017 - Issue 1

#ThinkSmiths

Happy to helpSmith's Environmental Products Ltd is one of the leading manufacturers of heating products in the UK. We are

committed to achieving the highest standards and our faith is supported by a free five year parts and labourguarantee with every product. Our customer service is second to none and we are happy to offer any help and

guidance that you might need.

StockistsAll products are available nationally from Builders’ Merchants, Plumbers’ Merchants, Heating Equipment

Distributors and Kitchen Equipment Distributors. In the event of difficulty, please contact us or visit our websitewww.SmithsEP.co.uk for details of your nearest stockist.

Information and adviceA product brochure containing full technical specifications and list prices is available to download from ourwebsite or in hard copy from our office. Also available on our website are price lists, individual product data

sheets, installation & user guides, where to buy, who to contact and a media centre.

Alternatively contact our office 9.00am to 5.00pm Monday to Friday.

For product information, customer services or sales support call us on

01245 324900For the Republic of Ireland, contact MT Agencies on 01 864 3363

[email protected]'s Environmental Products Ltd

Blackall Industrial Estate, South Woodham Ferrers, Chelmsford, Essex CM3 5UW

www.SmithsEP.co.uk

twen

ty

�fth anniversary

twenty �fth anniv

ersa

ry251991-2016


Recommended