+ All Categories
Home > Documents > COMMERCIAL_RANGE_03_13

COMMERCIAL_RANGE_03_13

Date post: 22-Mar-2016
Category:
Upload: baxi-spa
View: 225 times
Download: 5 times
Share this document with a friend
Description:
 
Popular Tags:
56
General catalogue COMMERCIAL AND TECHNICAL INFORMATION Commercial Range
Transcript
Page 1: COMMERCIAL_RANGE_03_13

General catalogueCOMMERCIAL AND TECHNICAL INFORMATION

Commercial Range

Page 2: COMMERCIAL_RANGE_03_13

2

How to read this catalogueIn this catalogue we show the high efficiency condensing system

complete range of BAXI products.

On each page, in addition to the product benefits, there

is a detailed list of the appliance characteristics, a technical chart,

and coloured icons.

These icons refer to the specific pages of the technical section of

the catalogue where, by segment, the technical drawings and all the

specific accessories are represented.

In the technical section you will find:

Dimensional technical drawingsGraphsFluesystems

Flue tube accessories

Hydraulic accessories

Thermo-regulation accessories

Otheraccessories

Company ProfileBAXI SPA has a proud tradition of developing and producing boilers

and heating systems to the highest technological standards.

For over 30 years BAXI SPA has provided a wide range of

cutting-edge solutions, anticipating market evolutions and paying

attention to customer needs.

Page 3: COMMERCIAL_RANGE_03_13

3

High output condensing systems

More details and information on the website

By accessing to the www.baxi.it, Reserved Area and then to the Tech Area,

just after a quick registration it is possible to display and download the

following documents:

• Certifications

• Fault Finding List

• General Catalogues

• Instructions Manuals

• PCB Service Instructions

• Spare Parts Catalogues

• Technical Drawings

• Technical INFO

• Technical presentations

IndexHigh output wall-hung condensing boilers 5

High output floor standing boilers 6

Built-in heat-boxes - Luna Sat 7

Luna Platinum 12 - 32 kW 9

Luna Duo-tec MP 50 - 110 kW 10

Modular heating system for Luna Duo-tec MP (GMC+1) 11

Power HT 45 - 150 kW 12

Power HT 230 - 320 kW 13

Power HT-A 430 - 650 kW 14

Luna Sat 15

Technical section 19

Page 4: COMMERCIAL_RANGE_03_13

4

High efficiency installationsBaxi condensing systems represent the ideal solution for installations where high outputs

are required.

The electronics platform of these boilers allows the control of single and cascade

installations and a complete range of thermoregulation accessories.

High modulation ratio The new ranges of high efficiency condensing boilers are distinguished by a wider

modulation ratio that grants a better efficiency thanks to reduced switch-on/ switch-off

of the boiler.

Cutting edge electronics The sophisticated electronics of the high efficiency condensing boilers allows to manage

single or cascade installation up to 16 boilers (Luna Duo-tec MP or Power HT 230-320).

It is just needed to connect the relevant accessories to the boiler’s electronics.

Compact weight and dimensions Compact weight and dimensions of Baxi high efficiency condensing systems, guarantee

the maximum flexibility and allow their installation also in small heat generator rooms.

Condensing technology is the latest face in boiler innovation. By employing

pre-mix burner know how, condensing boilers ensure higher performance

(efficiency up to 109,8%) thanks to the recovery of all the heat available

through combustion without wasting energy into the air, as happens with

traditional boilers.

Page 5: COMMERCIAL_RANGE_03_13

5

High output condensing systems

Luna Platinum1.12/1.18

Luna Platinum1.24/1.32

Luna Duo-tec MP

1.50

Luna Duo-tec MP

1.60

Luna Duo-tec MP1.70

Luna Duo-tec MP

1.90

Luna Duo-tec MP

1.110

Maximum Heat Output

80°/60° CkW

12/16,9 24/32 45 55 65 85 102

Maximum Heat Output

50°/30° C kW

13,1/18,4 26,1/34,9 48,6 59,4 70,2 91,8 110,2

High output wall hung boilers

Page 6: COMMERCIAL_RANGE_03_13

6

45-150 kW 230-320 kW 430-650 kW

Power HT1.450 - 1.650 - 1.850

1.1000 - 1.1150 - 1.1200

Power HT1.230 - 1.280 - 1.320

Power HT-A1.430 - 1.500 - 1.570 - 1.650

PowerHT

Maximum Heat

Output

80°/60° CkW

Maximum Heat

Output

50°/30° C kW

PowerHT

Maximum Heat

Output

80°/60° CkW

Maximum Heat

Output

50°/30° C kW

PowerHT-A

Maximum Heat

Output

80°/60° CkW

Maximum Heat

Output

50°/30° C kWModel Model Model

1.450 45 48,7 1.230 210,1 229,8 1.430 392,8 422,4

1.650 65 70,3 1.280 254,5 278,1 1.500 462 498,2

1.850 85 91,6 1.320 294 321,3 1.570 531,4 574,6

1.1000 100 107,8 1.650 601 651,5

1.1150 112 121,1

1.1200 120 129,7

1.1500 150 162

High output floor standing boilers

Page 7: COMMERCIAL_RANGE_03_13

7

High output condensing systems

Wireless and M-BUS built-in heat boxes

Heating only

Luna SAT RC - Luna SAT RC-MBLuna SAT R/1 - Luna SAT R/1-MB Luna SAT RH - Luna SAT RH-MB

Luna SAT RH1 - Luna SAT RH1-MBLuna SAT RHG1 - Luna SAT RHG1-MB

Luna SAT RC - RackLuna SAT RP/1 - Luna SAT RP/1-MBLuna SAT RPH - Luna SAT RPH-MB

Luna SAT RPB - Luna RPB-MBLuna SAT RPE - Luna SAT RPE-MB

Luna SAT RPEH - Luna SAT RPEH-MBLuna SAT RP-SP-MB+2C

Luna SAT R2ZLuna SAT R2Z-MB

Combi

Luna SAT RS - Luna SAT RS-MBLuna SAT RST-MB

Luna SAT RSP - Luna SAT RA Luna SAT RSP-MB

Luna SAT R60 WH-MB(for wall hung installationwith integrated cylinder)

Luna SAT RS2ZLuna SAT RA2Z

Heatingand cooling

Luna SAT R2H - Luna SAT R2H-MB

Without pump (mixing valve) With pump To manage 2 zones

- Luna Sat R/1, RH, RPB, RPE, RPEH, RH1 and RHG1 are available also with built-in flow-meters (M-BUS models as well)

- RH1 and RH1-MB models are available also with pressure reducer on the flow-meters.

Page 8: COMMERCIAL_RANGE_03_13

8

High outputcondensing systems Thermal systems for cascade installations Wall hung boilers - Luna Platinum 10 - Luna Duo-tec MP 11 - Modular heating system for Luna Duo-tec MP (GMC+) 12 Floor standing boilers - Power HT (outputs from 45 to 150 kW) 15 - Power HT (outputs from 230 to 320 kW) 16 - Power HT-A (outputs from 430 to 650 kW) 16 Wireless and M-BUS built-in heat boxes - Luna Sat-Heating only models 17 - Luna Sat-Heating and DHW production models 18

8

Page 9: COMMERCIAL_RANGE_03_13

9

High output condensing systems

Removable control panel for wall-hung installation with •

wide text display, regulation knob, menu selection buttons

and back-lighting supplied with the boiler

Wide modulation ratio up to • 1÷10:betterefficiencythanks

to reduced switch-on/switch-off of the boiler

Gas Adaptive Control (GAC) system: combustion automatic•

controltomaintainconstantlythehighestlevelofefficiency

Integrated control of a solar system*•

Complete soundproofing of the generator•

Circulating pump with full modulation•

Frontal access for advanced diagnostics•

Hydraulic system 3 way electric diverter valveStainless steel AISI 316L premixing burnerStainless steel AISI 316L water/flue heat exchangerStainless steel enhaced DHW exchanger to ensure condensation also in DHW modeModulating fan with electronic speed adjusting systemAutomatic by-passMulti-speeds low energy pump of the heating circuit with built- in air ventSystem to prevent pump and diverter valve sticking operating every 24 hoursCentral relief valve set at 3 bar

Thermoregulation systemBuilt-in climatic regulation (outdoor sensor available as optional)Control of multi-zones system optionCascade system installation optionRoom sensor, central heating and sanitary timers included in the control panel

Control system Overheat limit thermostat of the water/flue exchangerHydraulic pressure switch to prevent boiler operating in event of low waterSafety NTC sensor against flues overheatElectronic temperatures control by NTC sensorsFull anti-frost deviceElectronic thermometerDigital central heating pressure gauge

Luna Platinum 12-32 kW

1.12 1.18 1.24 1.32

Product code 7102665 7108435 7106583 7108436

Maximum heating heat input kW 12,4 17,4 24,7 33

Maximum heating heat output 80/60°C kW 12 16,9 24 32

Maximum heating heat output 50/30°C kW 13,1 18,4 26,1 34,9

Minimum heating heat output 80/60°C kW 2 2,4 2,4 3,2

Minimum heating heat output 50/30°C kW 2,2 2,7 2,7 3,5

Energetic efficiency (92/42/CEE)

Average efficiency (DIN 4702-T8) % 109,8 109,8 109,8 109,8

Nominal efficiency 80/60°C % 97,8 97,7 97,6 97,6

Nominal efficiency 50/30°C % 105,8 105,8 105,7 105,7

Efficiency 30% % 107,8 107,7 107,6 107,6

NOx class (EN 483) 5 5 5 5

Minimum working temperature °C -5 -5 -5 -5

Expansion vessel capacity/pre-charge l/bar 8/0,8 8/0,8 8/0,8 10/0,8

Heating temperature range. °C 25/80 25/80 25/80 25/80

Maximum pressure heating circuit bar 3 3 3 3

Coaxial flue system Ø 60/100 max length m 10 10 10 10

Dual flue system Ø 80 max length m 80 80 80 80

Maximum flue mass flow rate kg/s 0,006 0,008 0,012 0,016

Minimum flue mass flow rate kg/s 0,001 0,001 0,001 0,002

Maximum flue temperature °C 75 75 80 80

Dimensions (h x w x d) mm 760 x 450 x 345

Net weight kg 34,5 34,5 34,5 37,5

Gas type Natural Gas/LPG

Power consumption W 108 122 120 130

Grade of protection IPX5D IPX5D IPX5D IPX5D

Technical pages 20-28 38-43 44 48

*in case of contemporary control of a solar system and a zone by the wall-mounted control panel, it is necessary to install a programmable clip in/external module THINK.

Outputs from 12 to 32 kW

Page 10: COMMERCIAL_RANGE_03_13

10

Technical pages 21-30 38-43 45 48

Stainless steel AISI 316L single chamber•

(50 – 60 – 70 kW) and double chamber (90 – 110 kW)

exchanger: high output in compact size, reliability

and long life.

High modulation ratio (1• ÷9):betterefficiencythanks

to reduced switch-on/switch-off of the boiler

Digital control panel with push buttons and wide LCD •

display (numbers and symbols)

Compact size and minimal weight•

Complete range of accessories for single and cascade •

installations

Luna Duo-tec MP 50-110 kW

1.50 1.60 1.70 1.90 1.110

Product code 7104050 7104051 7104052 7104651 7104652

Maximum heating heat input kW 46,3 56,6 66,9 87,4 104,9

Maximum heating heat output 80/60°C kW 45 55 65 85 102

Maximum heating heat output 50/30°C kW 48,6 59,4 70,2 91,8 110,2

Minimum heat output 80/60°C kW 5 6,1 7,2 9,4 11,4

Minimum heat output 50/30°C kW 5,4 6,6 7,8 10,2 12,3

Energetic efficiency 92/42/CEE HHHH HHHH HHHH HHHH HHHH

Average efficiency (DIN 4702-T8) % 109,8 109,8 109,8 109,8 109,8

Nominal efficiency 80/60°C % 97,2 97,2 97,2 97,2 97,2

Nominal efficiency 50/30°C % 105 105 105 105 105

Efficiency at 30% % 107,8 107,4 107,1 107,5 107,4

NOx class (EN 483) 5 5 5 5 5

Minimum working temperature °C -5 -5 -5 -5 -5

Water content lt 4 5 6 9 10

Heating system max pressure bar 4 4 4 4 4

Safety valve intervention pressure bar 4 4 4 4 4

Regulation of water temperaturein heating circuit

°C 25/80 25/80 25/80 25/80 25/80

Coaxial flue system max length m 10 (Ø 80/125) 10 (ø 80/125) 10 (ø 80/125) 10 (ø 110/160) 10 (ø 110/160)

Dual flue system max length m 60 (ø 80) 60 (ø 80) 60 (ø 80) 27 (ø 110) 27 (ø 110)

Maximum flue mass flow rate kg/s 0,021 0,026 0,031 0,04 0,047

Minimum flue mass flow rate kg/s 0,002 0,003 0,004 0,005 0,005

Maximum flue temperature °C 80 80 74 70 70

Dimensions (h x w x d) mm 766x450x377 766x450x377 766x450x505 952x600x584 952x600x584

Net weight kg 40 40 50 83 93

Gas type Nat. gas/LPG

Power consumption W 190 210 210 275 320

Grade of protection IPX5D IPX5D IPX5D IPX5D IPX5D

Outputs from 50 to 110 kW

Hydraulic system Modulating pump included in the boilerSystem to prevent pump sticking operating every 24 hoursFlow and return NTC sensorsWater tray for condensate drain from supply air duct

Thermoregulation systemBuilt-in climatic regulation (outdoor sensor supplied as optional)Mixed zones systems (high and low temperatures) installation optionCascade system installation option (up to 16 boilers)NTC sensor for DHW cylinder control optionHeating and DHW timers integrated in the control panel

Control system Full electronic anti-frost deviceElectronic thermometerCentral heating pressure gaugeFlow over-temperature thermostat

Page 11: COMMERCIAL_RANGE_03_13

11

High output condensing systems

CABINETmade of:

N° of installed Boilers

LUNA DUO-TEC MP possible

configuration

Tot. installedkW

1 door*

1.50 1.601.70 50

6090

1101.901.110

2 doors*

or

1.50 1.601.701.90

1.110

From

50 kW

to

220 kW

3 doors*

or

1.50 1.601.701.90

1.110

From

50 kW

to

330 kW

Solutions with 1,2,3 doors cabinet•

Compact cabinet: 175 cm height•

Hydraulic separator can be assembled inside the •

cabinet

Insulated hydraulic collectors sustained by fixing •

brackets

Built-in condensate tray•

Hydraulic systemHydraulic connections between boilers and copper collectors

Integration of the hydraulic safety accessories

Expansion vessels included

Flow/return right or left side possibility

* to install the hydraulic compensator and the system accessories sheltered from the bad weather it is possible to order an additional cabinet

Modular heating systemfor Luna Duo-tec MP (GMC+)

Technical pages 22

NEW

Page 12: COMMERCIAL_RANGE_03_13

12

Hydraulic system Stainless steel AISI 316L premixing burnerStainless steel AISI 316L water/flue exchangerSystem to prevent pump sticking operating every 24 hours

Thermoregulation system Remote controller and climatic regulator (supplied as optional)Built-in weather compensation function (outdoor sensor supplied as optional)Mixed zones systems (low and high temperature) installation option Cascade system installation optionNTC sensor for DHW cylinder control option

Control system Central heating and indirect cylinder timerHydraulic pressure switch to prevent boiler operating in event of low waterFull electronic anti-frost deviceElectronic thermometer Central heating pressure gauge

Power HT 45-150 kW

Outputs from 45 to 150 kW

1.450 1.650 1.850 1.1000 1.1150 1.1200 1.1500

Product code WHS 43104560 43106560 43108560 43110060 43111260 43112060 43115060

Maximum heating heat input kW 46,4 67 87,2 102,7 115 123,2 154

Maximum heating heat output 80/60°C kW 45 65 85 100 112 120 150

Maximum heating heat output 50/30°C kW 48,7 70,3 91,6 107,8 121,1 129,7 162

Minimum heat output 80/60°C kW 11,8 13,4 32,2 35,8 39 39 40,4

Minimum heat output 50/30°C kW 12,8 14,5 34,9 38,8 42,1 42,1 43,7

Energetic efficiency 92/42/CEE HHHH HHHH HHHH HHHH HHHH HHHH HHHH

Average efficiency (DIN 4702-T8) % 109,8 109,8 109,8 109,8 109,8 109,8 109,8

Nominal efficiency 80/60°C % 97,3 97,3 97,5 97,4 97,4 97,4 97,4

Nominal efficiency 50/30°C % 105,2 105,3 105,1 105 105,3 105,3 105,2

Efficiency at 30% % 107,6 107,6 107,3 107,4 107,5 107,5 107,2

NOx class (EN 483) 5 5 5 5 5 5 5

Minimum working temperature °C -5 -5 -5 -5 -5 -5 -5

Safety valve intervention pressure bar 3 3 3 3 3 3 3

Heating system max pressure bar 4 4 4 4 4 4 4

Regulation of water temperaturein heating circuit

°C 25/80 25/80 25/80 25/80 25/80 25/80 25/80

Primary circuit water flow (ΔT=20°C) l/h 1.935 2.795 3.700 4.300 4.800 5.200 6.500

Water content l 5,1 6,5 13,7 21 23,3 23,3 25,3

Flue tube ø mm 80 80 100 100 100 100 100

Flue ducts max length m 30 20 20 20 20 20 20

Maximum flue mass flow rate kg/s 0,022 0,031 0,041 0,049 0,054 0,059 0,073

Minimum flue mass flow rate kg/s 0,006 0,007 0,016 0,018 0,019 0,019 0,02

Maximum flue temperature °C 72 73 78 80 72 77 75

Dimensions (h x w x d) mm 850x450x621 850x450x693 850x450x801 850x450x871 850x450x1024 850x450x1024 850x450x1132

Net weight kg 60 68 75 83 95 95 103

Gas type Nat. gas/LPG

Power consumption W 90 110 100 160 128 135 235

Stainless steel double chamber exchanger: high output in •

compact size, reliability and long life

Digital control panel “advanced CPS system” with push •

buttons and wide LCD display with text and symbols

Complete range of temperature regulation accessories•

Minimal weight and size•

Complete range of accessories for single •

and cascade installations

Technical pages 23-32 38-44 47 48

Page 13: COMMERCIAL_RANGE_03_13

13

High output condensing systems

Technical pages 25-32 42 48 50

Hydraulic system Hydraulic connections on the rear sideSticking pump check systemFlow and return NTC sensorsPremixed low-emissions burner

Thermoregulation system Built-in climatic regulation (outdoor sensor included)Mixed zones systems (high and low temperatures) zone controllers as optionalCascade system installation option (up to 16 boilers)NTC sensor for DHW cylinder control optionHeating and DHW scheduler integrated in the control panel

Control system Full electronic anti-frost deviceElectronic thermometerFlow over-temperature thermostat

Power HT 230-320 kW

Outputs from 230 to 320 kW

Aluminium-Silicon exchanger with glass wool insulation:•

highefficiencyandreliabilityandlonglife

Modulation ratio (1• ÷6)

Low emissions pre-mixing burner•

Digital control panel with back-lighted LCD display •

and advanced electronics to manage single and cascade

installations

Easy to transport and to install•

Low noise operational•

Power HT 1.230 Power HT 1.280 Power HT 1.320

Product code LSX 411230600 . 411280600 . 411320600 .Nominal heat output kW 215,0 260,0 300,0

Maximum heating heat output 80/60°C kW 210,1 254,5 294,0

Maximum heating heat output 50/30°C kW 229,8 278,1 321,3

Minimum heat output 80/60°C kW 33,5 40,2 45,9

Minimum heat output 50/30°C kW 37,4 44,9 51,4

Energetic efficiency 92/42/CEE

Average efficiency (DIN 4702-T8) % 109,6 109,7 109,7

Nominal efficiency 80/60°C % 97,9 98,0 98,0

Nominal efficiency 50/30°C % 106,9 107,0 107,1

Efficiency at 30% % 105,4 105,6 105,7

NOx Class (EN 483) 5 5 5

Minimum working temperature °C -5 -5 -5

Heating system max pressure bar 6 6 6

Water content lt 38 45 53

Flue ducts max length m 60 (Ø200) 60 (Ø200) 60 (Ø200)

Maximum flue mass flow rate kg/s 0,097 0,118 0,136

Minimum flue mass flow rate kg/s 0,016 0,019 0,021

Maximum flue temperature °C 61 60 60

Dimensions (h x w x d)* mm 1458x692x1231 1458x692x1324 1458x692x1417

Net weight kg 285 314 344

Gas type Natural Gas / LPG

Power consumption W 330 350 410

(*) Flue ducts and hydraulic pipes included

Page 14: COMMERCIAL_RANGE_03_13

14

Hydraulic system Hydraulic connections on the top sideSticking pump check systemFlow and return NTC sensorsPremixed low-emissions burner

Thermoregulation system Built-in climatic regulation (outdoor sensor included)Mixed zones systems (high and low temperatures) zone controllers as optionalCascade system installation option (up to 16 boilers)NTC sensor for DHW cylinder control optionHeating and DHW scheduler integrated in the control panel

Control system Full electronic anti-frost deviceElectronic thermometerFlow over-temperature thermostat

Power HT-A 430-650 kW

Outputs from 430 to 650 kW

Aluminium-Silicon exchanger with glass wool insulation:•

highannualefficiency,reliabilityandlonglife

Modulation ratio (1• ÷5)

Digital control panel with back-lighted LCD display •

and advanced electronics to manage single and cascade

installations

Easy to transport and to install•

Low noise operational•

Power HT 1.430 Power HT 1.500 Power HT 1.570 Power HT 1.650

Product code LSX 411430600 . 411500600 . 411570600 . 411650600 .Nominal heat output kW 400 470 540 610

Maximum heating heat output 80/60°C kW 392,8 462 531,4 601

Maximum heating heat output 50/30°C kW 422,4 498,2 574,6 651,5

Minimum heat output 80/60°C kW 77 91 105 119

Minimum heat output 50/30°C kW 84,8 99,8 115 130,4

Energetic efficiency 92/42/CEE

Average efficiency (DIN 4702-T8) % 109,4 109,3 109,2 109,1

Nominal efficiency 80/60°C % 98,2 98,3 98,4 98,5

Nominal efficiency 50/30°C % 105,6 106 106,4 106,8

NOx Class (EN 483) 5 5 5 5

Minimum working temperature °C -5 -5 -5 -5

Heating system max pressure bar 6 6 6 6

Water content lt 73 84 97 106

Flue ducts max length m 60 (Ø250) 60 (Ø250) 60 (Ø250) 60 (Ø250)

Maximum flue mass flow rate kg/s 0,188 0,22 0,253 0,286

Minimum flue mass flow rate kg/s 0,038 0,044 0,05 0,057

Maximum flue temperature °C 60 60 60 60

Dimensions (h x w x d)* mm 1526x762x1882 1526x762x2192 1526x762x2192 1526x762x2192

Net weight kg 540 598 636 674

Gas type Natural Gas / LPG

Power consumption W 463 583 790 750

(*) Flue ducts and hydraulic pipes included

43Technical pages 27-33 37-38

NEW

Page 15: COMMERCIAL_RANGE_03_13

15

High output condensing systems

Luna Sat-Heating only modelsModels without pump

R/1: KSV 71411151R/1-MB: KSV 71411541

RC: KSV 71413111RC-MB: KSV 71413121

RH: KSV 71411321RH-MB: KSV 71411591

RH1: KSV 71411811RH1-MB: KSV 71411851

RHG1: KSV 71412361RHG1-MB: KSV 71412371

R2H: KSV 71412041R2H-MB: KSV 71412051

RC R/1 RH RH1 RHG1 R2H**

Heating circuit maximum pressure bar 4 4 4 4 4 4

Water contents I 0,5 1,5 1,5 1,5 2 1,5

Power supply voltage V 230 230 230 230 230 230

Power supply frequency Hz 50 50 50 50 50 50

Power consumption W 15 15 15 15 15 15

Width of the case mm 450 600 650 400* 500 800

Height of the case mm 450 650 650 600* 850 750

Depth of the case mm 110 150 150 200* 150 150

Net weight Kg 3,2 11 11 9 13 9

Maximum temperatureof the warm fluid (inlet)

°C 90 90 90 90 90 90

Feed flow (inlet) l/h 700÷ 1000 l/h 700÷ 1000 l/h 700÷ 1000 l/h 700÷ 1000 l/h 700÷ 1000 l/h 700÷ 1000 l/h

Flow-losses kPa 20Kpa at 700 l/h 20Kpa at 700 l/h 20Kpa at 700 l/h 20Kpa at 700 l/h 20Kpa at 700 l/h 20Kpa at 700 l/h

(*) The case can not be used. Measures are referred to RPH and RH1 models without casing including interception taps (**) For heating and cooling

Technical pages 34 51

Page 16: COMMERCIAL_RANGE_03_13

16

RP/1: KSV 71411161RP/1-MB: KSV 71411551

R2Z: KSV 71410101R2Z-MB: KSV 71411901

RPH: KSV 71411331RPH-MB: KSV 71411601

RPE: KSV 71411911RPE-MB: KSV 71411921

RPEH: KSV 71412451RPEH-MB: KSV 71412461

RP-SP-MB + 2C: KSV 71414401

RPB: KSV 71411171RPB-MB: KSV 71411581

RP/1 RPH RPB RPE RPEH RP-SP-MB+2C R2ZModels with pump • • • • • • •

Models with 2nd zone - - - - - - •

Heating temperature regulationwith high climatic curve °C - - - 25/80 - - 25/80

Heating circuit maximum pressure bar 4 4 4 4 4 4 4

Water contents I 2 2 2 2 2 9,5 3,5

Power supply voltage V 230 230 230 230 230 230 230

Power supply frequency Hz 50 50 50 50 50 50 50

Power consumption W 110 110 110 110 110 110 210

Width of the case mm 600 600* 600 600 600 600 800

Height of the case mm 650 716* 650 650 850 850 750

Depth of the case mm 150 150* 150 150 150 150 150

Net weight Kg 13 13 12 13,50 14 17 22

Maximum temperatureof the warm fluid (inlet)

°C 90 90 90 90 90 90 90

Feed flow (inlet) l/h 700÷ 1000 l/h 700÷ 1000 l/h 700÷ 1000 l/h 700÷ 1000 l/h 700÷ 1000 l/h 700÷ 1000 l/h 700÷ 1000 l/h

Flow-losses kPa 20Kpa at 700 l/h 20Kpa at 700 l/h 20Kpa at 700 l/h 20Kpa at 700 l/h 20Kpa at 700 l/h 20Kpa at 700 l/h 20Kpa at 700 l/h

(*) The case can not be used. Measures are referred to RPH and RH1 models without casing including interception taps

Luna Sat-Heating only modelsModels with pump

Model to manage2 different zones

NEW

Technical pages 34 51

Page 17: COMMERCIAL_RANGE_03_13

17

High output condensing systems

Luna Sat-Heatingand DHW production models

RSP: KSV 71410091RSP-MB: KSV 71411571

RS2Z: KSV 71410111 RA: KSV 71410771

R60WH-MBKSV 71413071

RST-MB: KSV 71413971RA2Z: KSV 71410781

RSP RS2Z RA R60WH RA2Z RSTDHW production • • • • • •

Models with pump • • • • • -

Models with 2nd zone - • - - • -

Heating temperature regulation withhigh climatic curve

°C 25/80 25/80 25/80 25/80 25/80 25/80

DHW regulation °C 30/60 30/60 30/65 30/65 30/65 30/60

DHW production with ΔT=35°Cand inlet water temperature 75°C

l/m 14,3 14,3 14,3 14,3 14,3 14,3

Heating circuit maximum pressure bar 4 4 4 4 4 4

DHW circuit maximum pressure bar 8 8 8 8 8 8

DHW circuit minimum pressure bar 0,2 0,2 0,2 0,2 0,2 0,2

Water contents l 2,5 4 2 5 4 2

Power supply voltage V 230 230 230 230 230 230

Power supply frequency Hz 50 50 50 50 50 50

Power consumption W 110 210 150 110 210 15

Width of the case mm 600 800 600 910 800 600

Height of the case mm 650 750 650 450 750 600

Depth of the case mm 150 150 150 473 150 150

Net weight Kg 18 28 16 38 25 16

Maximum temperatureof the warm fluid (inlet)

°C 90 90 90 90 90 90

Feed flow (inlet) l/h 1000÷ 1500 1000÷ 1500 1000÷ 1500 1000÷ 1500 1000÷ 1500 1000÷ 1500

Flow-losses kPa 20Kpa at 700 l/h 20Kpa at 700 l/h 20Kpa at 700 l/h 20Kpa at 700 l/h 20Kpa at 700 l/h 20Kpa at 700 l/h

Technical pages 34 51

Page 18: COMMERCIAL_RANGE_03_13

18

Luna Sat RC in Rack

MR1-MR2-MR3 = apartment heating flowRR1- RR2 - RR3 = apartment heating returnUC1 - UC2 - UC3 = heat meter outlet 1 - 2 - 3 to the apartmentIP = primary inlet from centralized systemUP = primary outlet to the centralized systemEC1 = inlet to the first heat meter

AE = hole for cables

MR1-MR2-MR3 = apartment heating flowRR1- RR2 - RR3 = apartment heating returnUC1 - UC2 - UC3 = heat meter outlet 1 - 2 - 3 to the apartmentIP = primary inlet from centralized systemUP = primary outlet to the centralized systemEC1 = inlet to the first heat meter system

AE = hole for cables

Parallel assembly of 3 or 4 Luna Sat RC or RC-MB option•

Up to 3 flow meters for each Luna Sat RC installation option•

Insulated hydraulic manifolds available as option•

Built-in taps in the casing•

RCHeating circuit maximum pressure bar 4

Water content l 0,5

Power supply voltage V 230

Power supply frequency Hz 50

Power consumption W 15

Width of the case mm 450

Height of the case mm 450

Depth of the case mm 110

Net weight Kg 3,2

DIMENSIONS3 modules Rack 4 modules Rack

NEW

Technical pages 34 51

Page 19: COMMERCIAL_RANGE_03_13

19

High output condensing systems

Technical Section

Technical drawings 20 GraphsFlue systems

Flue pipes accessories 37

Hydraulic accessories 44

Thermoregulation accessories 48

Other accessories 51

Products technical data 53

19

Page 20: COMMERCIAL_RANGE_03_13

20

Technical drawings - graphs - flue systems Technical drawings - graphs - flue systems

450

760

345

177

131m

in.

140,5

65,5

54,5

43,5

32,5

21,5

10 200 400 600

FLOW RATE/HEAD CURVE

FLOW RATE (l/h)

HEAD

800 1000

MAX

MIN

1200 1400

30 35 40

Effic

ienc

y of

the

boile

r %

Return temperature of the system °C

EFFICIENCY OF THE BOILER ACCORDING TO THE RETURN TEMPERATURE

30% load100% load

45 50 55 60979899

100101102103104105106107108

30 35 40

Flue

s te

mpe

ratu

re %

Return temperature of the system °C

45 50 55 6030354045505560657075

100% load

30% load

FLUES TEMPERATURE ACCORDING TO THE RETURN TEMPERATURE

S.C. Condensing trap that can be installed on a Ø 21 pipeM.R. Heating system flow G 3/4”M.B. Storage tank flow G 3/4”GAS Gas inlet G 3/4”E.S. Mains water G 1/2”R.R. Heating system return G 3/4”

M.B.

Luna Platinum1.12-1.18-1.24-1.32

High output condensing system

Page 21: COMMERCIAL_RANGE_03_13

Technical drawings - graphs - flue systems

21

Technical drawings - graphs - flue systems

(A) 377 mm Mod. 1.50-1.60 505 mm Mod. 1.70

Coaxial flue system ø 80/125Dual flue system ø 80

Coaxial flue system ø 110/160Dual flue system ø 110

Luna Duo-tec MP 1.50-1.60-1.70

Luna Duo-tec MP 1.90-1.110�������������������

450 (A)

225

140

763

225 229

600

354,5

223

952

245,5 112

584

S.C GAS M.R. R.R.S.C GAS M.R. R.R.

GAS Gas inlet G ¾”M.R. Heating system flow (G1”) with cylinder connection optionR.R. Heating system return (G1”) with cylinder connection optionS.C. Condensing trap that can be installed on a Ø 21 pipe

GAS Gas inlet G 1”M.R. Heating system flow (G1-G1/2”) with cylinder connection optionR.R. Heating system return (G1-1/2”) with cylinder connection optionS.C. Condensing trap that can be installed on a Ø 21 pipe

FLOW RATE (l/h)

HEAD

(mH 2

O)

FLOW RATE/HEAD CURVELUNA DUO-TEC MP 1.50 - 1.60

HEAD

(mH 2

O)

FLOW RATE (l/h)

FLOW RATE/HEAD CURVELUNA DUO-TEC MP 1.110

FLOW RATE (l/h)

HEAD

(mH 2

O)

FLOW RATE/HEAD CURVELUNA DUO-TEC MP 1.90

30 35 40

Effic

ienc

y of

the

boile

r %

Return temperature of the system °C

EFFICIENCY OF THE BOILER ACCORDING TO THE RETURN TEMPERATURE

30% load100% load

45 50 55 60979899

100101102103104105106107108

HEAD

(mH 2

O)

FLOW RATE (l/h)

FLOW RATE/HEAD CURVELUNA DUO-TEC MP 1.70

30 35 40

Flues

tem

pera

ture

%

Return temperature of the system °C

45 50 55 6030354045505560657075

100% load

30% load

FLUES TEMPERATURE ACCORDING TO THE RETURN TEMPERATURE

High output condensing system

Page 22: COMMERCIAL_RANGE_03_13

22

Technical drawings - graphs - flue systems Technical drawings - graphs - flue systems

High output condensing systemModular heating system for Luna Duo-tec MP (GMC+) - 1 door

Modular heating system for Luna Duo-tec MP (GMC+) - 2 doors

Modular heating system for Luna Duo-tec MP (GMC+) - 3 doors

Dimensions (mm) Modules W H D

2 doors 1600 1750 800

Dimensions (mm) Modules W H D

1 door 803 1750 800

Dimensions (mm) Modules W H D

3 doors 2400 1750 800

1750

216

149O

128314 205 281

800

417

260

120

310

401,5 401,5

193

456 347

1750

216

149O

128314 205 281

800

417

260

120

310

401,5 401,5

193

456 347

1750

216

149O

128314 205 281

800

417

260

120

310

401,5 401,5

193

456 347

1750

216

149O

1600 128314 205 281

800

260

120

417

310

401,5 800 401,5

193

456 800 347

1750

216

149O

310

401,5 800 800 401,5

193

456 800 800 347

2400

800

260

120

128314 205 281

417

1750

216

149O

310

401,5 800 800 401,5

193

456 800 800 347

2400

800

260

120

128314 205 281

417

1750

216

149O31

0

401,5 800 800 401,5

193

456 800 800 347

2400

800

260

120

128314 205 281

417

1750

216

149O

310

401,5 800 800 401,5

193

456 800 800 347

2400

800

260

120

128314 205 281

417

1750

216

149O

1600 128314 205 281

800

260

120

417

310

401,5 800 401,5

193

456 800 347

1750

216

149O

1600 128314 205 281

800

260

120

417

310

401,5 800 401,5

193

456 800 347

1750

216

149O

1600 128314 205 281

800

260

120

417

310

401,5 800 401,5

193

456 800 347

1750

216

149O

1600 128314 205 281

800

260

120

417

310

401,5 800 401,5

193

456 800 347

frontal view

frontal view

frontal view

side view

side view

side view

up view

Luna Duo-tec MP 90-110

Luna Duo-tec MP 90-110

Luna Duo-tec MP 50-60-70

Luna Duo-tec MP 50-60-70

Page 23: COMMERCIAL_RANGE_03_13

Technical drawings - graphs - flue systems

23

Technical drawings - graphs - flue systems

Depth (A) mm

Placement RVA

Power HT

45 cm

45 cm/ 2 cm

45 cm/ 2 cm

EXCHANGER PRESSURE LOSS

FLOW RATE (l/h)

EXCH

ANGE

R PR

ESSU

RE L

OSS

(mH 2

O)

EXCHANGER PRESSURE LOSS

FLOW RATE (l/h)

EXCH

ANGE

R PR

ESSU

RE L

OSS

(mH 2

O)

FLOW RATE/HEAD CURVE

FLOW RATE (l/h)

HEAD

(mH 2

O)

EXCHANGER PRESSURE LOSS

FLOW RATE (l/h)

EXCH

ANGE

R PR

ESSU

RE L

OSS

(mH 2

O)

Power HTTo allow an easy access for the boiler maintenance, the

minimum recommended distance must be observed

High output condensing systemPower HT 45-150 kW

Page 24: COMMERCIAL_RANGE_03_13

24

Technical drawings - graphs - flue systems Technical drawings - graphs - flue systems

450 450 450

20 20

936,

5

436,5

186,

580

0

136,

5

(*) - The distance between the boilers in cascade varies from 450 mm to 20 mm depending on manifold accessory used. Flow/return manifolds squared 100x100 with flanges DN80 PN6

* *

High output condensing systemPower HT 45-150 kW

Page 25: COMMERCIAL_RANGE_03_13

Technical drawings - graphs - flue systems

25

Technical drawings - graphs - flue systems

1.230 1.280 1.320

1.269 1.362 1.452Depth (A) mm

Power HT

Return

Flow

Flange

Flange

1000

100

10

10 11 100

POWER HT 1.230

POWER HT 1.280

POWER HT 1.320

FLOW RATE [m3/h]

WAT

ER S

IDE R

ESIS

TANC

E (m

bar)

EXCHANGER PRESSURE LOSSES

HEAT PRODUCTION ACCORDINGTO THE OUTDOOR TEMPERATURE

Outdoor temperature °C

Characteristic curve

Dew point = 54°CHeating flow

Heating return

Heat

ing w

ater

tem

pera

ture

EFFICIENCY OF THE BOILER ACCORDING TO THE OUTPUT

Output %

Effic

iency

%

High output condensing systemPower HT 230-320 kW

Page 26: COMMERCIAL_RANGE_03_13

26

Technical drawings - graphs - flue systems Technical drawings - graphs - flue systems

A B

1 Remove lower rear wall (2) of the Power HT

2 Remove the gas connection leading upward

and insert a 87°bend (1)

3 Turn 87°bend (1) in the desired position

(side or towards the rear)

4 Remove either the rear cover plate (3) or the

side cover plate (4)

5 Mount lower rear wall (2)

Side supply air connection (A)

1 Remove lower rear wall (3)

2 Remove the covering panel (2)

3 Mount the bend of the intake pipe (1)

4 Turn intake pipe elbow into the side position (1)

5 Mount lower rear wall (3)

Rear supply air connection (B)

1 Remove lower rear wall (2)

2 Take out cover plate (3)

3 Mount straight intake pipe

4 Mount lower rear wall (2)

Max lengths for the flue pipes with room air dependent working (type B installation)

These lengths are only for single boilersDecrease of the total lengths of the flue pipes:1 piece 87° bend: 5 m1 piece 45° bend: 2 m1 piece 15° bend: 1 m

Model Power HT 1.230 Power HT 1.280 Power HT 1.320

Flue pipe - ø mm 200 200 200

Max L. pipe inc. 87° bend mm 60 60 60

High output condensing systemPower HT 230-320 kW

Page 27: COMMERCIAL_RANGE_03_13

Technical drawings - graphs - flue systems

27

Technical drawings - graphs - flue systems

Flue systemPower HT-A (430-650 kW)

Power HT-A (dimensions) 1.430 1.500 1.570 1.650

A mm 642 642 642 642

B mm 798 1009 1009 1009

C mm 442 540 540 540

D mm 1882 2192 2192 2192

E mm 709 1018 1018 1018

F mm 1526* 1526* 1526* 1526*

G mm 762 762 762 762

F

G

F

G

1.430 1.500 1.570

1.882 2.192 2.192

1.650

2.192Depth (D) mm

Power HT-A

0 5 10 15 20 25 30 35 40 45 50 550

50

100

150

200

250

300

350

400

450

500

550

600

FLOW RATE [m3/h]

WAT

ER S

IDE R

ESIS

TANC

E (m

bar)

EXCHANGER PRESSURE LOSSES

POWER HT-A 1.430

POWER HT-A 1.650

POWER HT-A 1.570

POWER HT-A 1.500

Heating return

Dew point = 54°C

Outdoor temperature °C

Heating flow

Heat

ing w

ater

tem

pera

ture

Characteristic curve

HEAT PRODUCTION ACCORDING TO THE OUTDOOR TEMPERATURE

EFFICIENCY OF THE BOILER ACCORDING TO THE OUTPUT

Output %

Effic

iency

%

* flue ducts and hydraulic pipes included

Page 28: COMMERCIAL_RANGE_03_13

28

Technical drawings - graphs - flue systems Technical drawings - graphs - flue systems

Coaxial flue system Luna Platinum

ExampleofinstallationwithhorizontalfluesystemØ60/100andØ80/125

InstallationexampleswithLASchimneyØ60/100andØ80/125

Verticalchimneyterminalforcoaxialfluesystem

InstallationexamplewithverticalcoaxialflueductsØ60/100andØ80/125

frontal view side view

450 345

KHG 714093910 .Reduction from Ø 80/125 to Ø 60/100

KHG 714093510 .Vertical chimney terminal for coaxial flue system Ø 60/100

Ø 126

130

50

Ø 60

Ø 100

Ø 81,5

Tubes maximumlength (m) Length reduction

for a 90° bend insertion (m)

Length reduction for a 45° bend

insertion (m)Ø 60/100 Ø 80/125

10 25 1 0,5

Page 29: COMMERCIAL_RANGE_03_13

Technical drawings - graphs - flue systems

29

Technical drawings - graphs - flue systems

Dual flue system Luna Platinum

Exampleofinstallationwithverticaldualfluesystem Installationexamplewithhorizontaldualflueducts

Verticalchimneyterminalfordualfluesystem

frontal view frontal viewside view side view

KHG 714093810 .Dual flue pipes adapter for coaxial chimney (Ø 80/80 to Ø 80/125)

KHG 714093510 .Vertical chimney terminal Ø 80/125

Intake pipe maximum length: 15 m.

Ø 126

200

138

50

Ø 80

Page 30: COMMERCIAL_RANGE_03_13

30

Technical drawings - graphs - flue systems Technical drawings - graphs - flue systems

Flue system – Coaxial flue systemLuna Duo-tec MP

COAXIAL FLUE SYSTEMLunaDuo-tecMP1.50-1.60-1.70=Ø80/125mmLunaDuo-tecMP1.90-1.110=Ø110/160mm

DUAL FLUE SYSTEMLunaDuo-tecMP1.50-1.60-1.70=Ø80+80mmLunaDuo-tecMP1.90-1.110=Ø110+110mm

LunaDuo-tecMP–CoaxialfluesystemInstallationexamplewithcoaxialflueductsØ80/125(mod.1.50-1.60-1.70)andØ110/160(mod.1.90-1.110)

Type of ductTubes maximum

length(m)

Length reduction for a90° bendinsertion

(m)

Length reduction for a45° bend insertion

(m)

Ø chimney terminal(mm) Ø external duct

Coaxial Ø 110/160 mm 10 m 1 m 0,5 m 163 mm 160 mm

Vertical dual flue system 15 m 0,5 m 0,25 m 163 mm 110 mm

Coaxial Ø 85/125 mm 10 m 1 m 0,5 m 133 mm 125 mm

Vertical dual flue system 15 m 0,5 m 0,25 m 133 mm 80 mm

Horizontal dual flue system* 60 m 0,5 m 0,25 m - 80 mm

* intake pipe maximum length: 15 m.

Page 31: COMMERCIAL_RANGE_03_13

Technical drawings - graphs - flue systems

31

Technical drawings - graphs - flue systems

Dual flue system

Installationexamplewithhorizontaldualflueducts

Exampleofinstallationwithverticaldualfluesystem

Luna Duo-tec MP 1.50 - 1.70 Luna Duo-tec MP 1.90 - 1.110

Intake pipe maximum length: 15 m

Page 32: COMMERCIAL_RANGE_03_13

32

Technical drawings - graphs - flue systems Technical drawings - graphs - flue systems

Flue system

Power HT (230-320 kW) – Flue/Intake pipes

These lengths are only for single boilersDecrease of the total lengths of the flue pipes: 1 piece 87° bend: 5 m - 1 piece 45° bend: 2 m - 1 piece 15° bend: 1 m

Power HT (45-150 kW) – Flue pipe

Model Tubes maximumlength (m)

Length reduction for a90° bend insertion (m)

Length reduction for a45° bend insertion (m)

HT 1.450 30 1 0,5HT 1.650 20 1 0,5HT 1.850 20 1 0,5HT 1.1000 20 1 0,5HT 1.1150 20 1 0,5HT 1.1200 20 1 0,5HT 1.1500 20 1 0,5

Power HT 1.230 Power HT 1.280 Power HT 1.320

Ø flue pipe mm 200 200 200Tube maximum length including 1 87° bend (m) mm 60 60 60

flow

return

flange DN 65

flange DN 65

Page 33: COMMERCIAL_RANGE_03_13

Technical drawings - graphs - flue systems

33

Technical drawings - graphs - flue systems

These lengths are only for single boilersDecrease of the total lengths of the flue pipes: 1 piece 87° bend: 5 m - 1 piece 45° bend: 2 m - 1 piece 15° bend: 1 m

Power HT-A 1.430 Power HT-A 1.500 Power HT-A 1.570 Power HT-A 1.650

Ø flue pipe mm 250 250 250 250Tube maximum length including 1 87° bend (m) mm 50 50 50 50

Flue systemPower HT-A 430-650 kW - Flue / Intake pipes

Power HT-A 1.430 1.500 1.570 1.650

MR Heating flow Flange DN 80 PN 6

RR Heating return Flange DN 80 PN 6

Gas Gas outlet R2" external threaded

A Rear flue outlet (optional) DN 250

B Provided rear supply air connection nom. diam. 160

C Condensated water connection (right or left) DN 32

D Safety hydraulic group connection R¾" external threaded

E Safety valve connection R2" external threaded

F Provided top flue connection DN 250

G Side supply air inlet (optional) nom. diam. 160

A

B

G

E

F

D

C

Page 34: COMMERCIAL_RANGE_03_13

34

Technical drawings - graphs - flue systems Technical drawings - graphs - flue systems

Models: Luna Sat R2Z - RS2Z - RA2Z

Models: Luna Sat R/1 - RP/1 - RPB - RPE - RSP - RA

Model: Luna Sat RC

dimensions in mm

left side view

View from A

View from A

Screws seatsConnection tongues

Equiment of the case

Equiment of the case

Insert the final part of the pipes inside the case

Insert the final part of the pipes inside the case

sx

View from below

right side view left side view

450

42

6842

110

MR

RR

USC

1U

SC 2

USC

3

8570

7070

45

77 33 110

Upper view from A

Casing height 650

USC1 USC2

L of the casing 800

L of the casing 600

IPU

PESC

1ESC

2ESC

3

L of the casing 450

The holes for hydraulic connections are on all sides of the casing

Model: Luna Sat RH

Screws seats

Frontal view Left side view

Case width 150

L of

the

cas

e 65

0

Con

nect

ion

kit

30

The uprights of the centralized network can beintercepted also by lateral sides of the case

CENTRALIZED SYSTEM CONNECTIONSIP : Primary inlet from centralized system G3/4’’ MUP: Primary outlet to centralized system G3/4’’M

APARTMENT SIDE HEATING CONNECTIONS-MONOZONE MODELSMR: heating G 3/4’’ M apartment flowRR: heating G 3/4’’ M apartment return

DHW CONSUMPTION METER CONNECTIONSESC1 : cold water inlet to first heat meter G 3/4 “ MESC2 : cold water inlet to second heat meter G 3/4 “ MESC3 : cold water inlet to third heat meter G 3/4 “ M

USC1: water outlet from first heat meter G 3/4 “ MUSC2: water outlet from second heat meter G 3/4 “ MUSC3: water outlet to third heat meter G 3/4 “ M

CENTRALIZED SYSTEM CONNECTIONSIP : Primary inlet from centralized system G3/4’’ MUP: Primary outlet to centralized system G3/4’’M

APARTMENT SIDE HEATING CONNECTIONS-MONOZONE MODELSMR: heating G 3/4’’ M apartment flowRR: heating G 3/4’’ M apartment return

DHW CONSUMPTION METER CONNECTIONSES: Cold water inlet G 1/2 “ M ( RSP mod.)US: DHW outlet G 1/2 “ M ( RSP mod.)ESC1: cold water inlet to first heat meter G 3/4 “ MESC2 : cold water inlet to second heat meter G 3/4 “ M

CENTRALIZED SYSTEM CONNECTIONS- in case of high temperature zonesMRAT: high temperature zone G 1/2’’ M apartment flow RRAT: high temperature zone G 1/2’’ M apartment return

CENTRALIZED SYSTEM CONNECTIONSIP : Primary inlet from centralized system G3/4’’ MUP: Primary outlet to centralized system G3/4’’M

HEATING SYSTEM CONNECTIONS – BIZONE MODELSMRAT: high temperature zone G 3/4’’ M apartment flow MRBT: low temperature zone G 3/4’’ M apartment flow RRAT: high temperature zone G 3/4’’ M apartment return RRBT: low temperature zone G 3/4’’ M apartment return

DHW CONSUMPTION METER CONNECTIONSES: water inlet to the first heat meter G 1/2 “MUS: water outlet to the first heat meter G 1/2 “ MESC1 : cold water inlet to first heat meter G 3/4 “ MESC2 : cold water inlet to second heat meter G 3/4 “ M

AE: hole for cables

CENTRALIZED SYSTEM CONNECTIONSIP : Primary inlet from centralized system G3/4’’ MUP: Primary outlet to centralized system G3/4’’M

APARTMENT SIDE HEATINGCONNECTIONS-MONOZONE MODELSMR: heating G 3/4’’ M apartment flowRR: heating G 3/4’’ M apartment return

DHW CONSUMPTION METERCONNECTIONSESC1 : cold water inlet to first heat meter G 3/4 “ MESC2 : cold water inlet to second heat meter G 3/4 “ M

USC1: water outlet from first heat meter G 3/4 “ MUSC2: water outlet from second heat meter G 3/4 “ M

AE: hole for cables

left side viewFrontal view

Screws seats Connection tongues

dx

(A)

(A)

(A)

Frontal view

Luna Sat

Frontal view

Page 35: COMMERCIAL_RANGE_03_13

Technical drawings - graphs - flue systems

35

Technical drawings - graphs - flue systems

Models: Luna Sat R2H

Models: Luna Sat RHG1

Frontal view

420

Screws seats

conn

ectio

n ki

t 14

4

872

327,

533

520

9,5

155,

5

conn

ectio

n ki

t 14

4

39,562,5

Left side view

Depth of the casing 150

Hei

ght

of t

he c

asin

g 85

0

Depth of the casing 150

H c

asse

tta

850

162,5

AEMR RR USC1 USC2

24140 57,5

73108

7742

70 70

162,5

24

AE

IP UP ESC1

ESC2

140 57,5

73108

7742

70 70

L of the casing 500

Models: Luna Sat RPEH

CENTRALIZED SYSTEM CONNECTIONSIP : Primary inlet from centralized system G3/4’’ MUP: Primary outlet to centralized system G3/4’’M

APARTMENT SIDE HEATING CONNECTIONS-MONOZONE MODELSMR: heating G 3/4’’ M apartment flowRR: heating G 3/4’’ M apartment return

APARTMENT DHW CONNECTIONSUCS: DHW thermostatic outlet UFS: Cold water outletEFS: Cold water inlet

AE: hole for cables

CENTRALIZED SYSTEM CONNECTIONS IP1: heating inlet from the centralized system G 3/4’’ M UP1: heating outlet from the centralized system G 3/4’’ M IP2: cooling inlet from the centralized system G 3/4’’ M UP2: cooling outlet from the centralized system G 3/4’’ M

HEATING-COOLING APARTMENT CONNECTIONSMR1: heating apartment flow G 3/4 “ MRR1: heating apartment return G 3/4 “ MMR2: cooling apartment flow G 3/4 “ MRR2: cooling apartment return G 3/4 “ M

DHW CONSUMPTION METER CONNECTIONSESC1 : cold water inlet to first heat meter G 3/4 “ MESC2: cold water inlet to second heat meter G 3/4 “ MUSC1: water outlet from first heat meter G 3/4 “ MUSC2: water outlet from second heat meter G 3/4 “ M

AE: hole for cables

CENTRALIZED SYSTEM CONNECTIONSIP : Primary inlet from centralized system G3/4’’ MUP: Primary outlet to centralized system G3/4’’M

APARTMENT SIDE HEATING CONNECTIONS-MONOZONE MODELSMR: heating G 1’’ M apartment flowRR: heating G 1’’ M apartment return

DHW CONSUMPTION METER CONNECTIONSESC1 : cold water inlet to first heat meter G 3/4 “ or G 1’’ MESC2 : cold water inlet to second heat meter G 3/4 “ or G 1’’ MUSC1: water outlet from first heat meter G 3/4 “ or G 1’’ MUSC2: water outlet from second heat meter G 3/4 “ or G 1’’ M

AE: hole for cables

Internal view of the casing from B

External view of the case from B

Internal view of the case from B

External view of the casing from A

External view of the casing from A

Internal view of the casing from A

Screws seats

Connection tongues

Depth of the casing 150

Frontal view

Left side view

Screws seats

Left side viewFrontal view

L of the casing 800

L of the casing 600

(A)

(A)

(B)

(A)

(B)

(B)Equiment of the case

Insert the final part of the pipes inside the case

Insert the final part of the pipes inside the casing

Page 36: COMMERCIAL_RANGE_03_13

36

Technical drawings - graphs - flue systems Technical drawings - graphs - flue systems

Model: Luna Sat R60WH

Model: Luna Sat RST

Frontal view

Frontal view

View from left side

View from left side

View from below

L of the box 150

L of the casing 600

Cas

e he

ight

850

View from below

Upper view

Upper view

Model: Luna Sat RP-SP

450

50

MR RR US UPVS

IP ES

65 65 7537,5

70 65 60

425

910

48 33

821

Ø 8

= =

2 holes for screws

Frontal view

450 473

View from left side

910

Sedi per viti

IP UP

MRAE

123 65 411

8565

48 6065 65 65 1386594

6585

29

4675

646

RR

V

Alette aggancio

Model: Luna Sat RH1without casing

Model: Luna Sat RPHwithout casing

IP UP

ESC2

USC2

RRMR

ESC1

USC1

H=8

46 m

in.

120

120

238

38

L 400 min.

76,5

70

38

85 50

292

16,5

70

352

235

CENTRALIZED SYSTEM CONNECTIONSIP : Primary inlet from centralized system G3/4’’ MUP: Primary outlet to centralized system G3/4’’M

APARTMENT SIDE HEATING CONNECTIONS-MONOZONE MODELSMR: heating G 3/4’’ M apartment flowRR: heating G 3/4’’ M apartment return

DHW CONSUMPTION METER CONNECTIONSESC1 : cold water inlet to first heat meter G 3/4 “ MESC2 : cold water inlet to second heat meter G 3/4 “ M

USC1: water outlet from first heat meter G 3/4 “ MUSC2: water outlet from second heat meter G 3/4 “ M

AE: hole for cables

CENTRALIZED SYSTEM CONNECTIONSIP : Primary inlet from centralized system G3/4’’ MUP: Primary outlet to centralized system G3/4’’M

APARTMENT SIDE HEATING CONNECTIONS-MONOZONE MODELSMR: heating G 3/4’’ M apartment flowRR: heating G 3/4’’ M apartment return

DHW CONSUMPTION METER CONNECTIONSESC1 : cold water inlet to first heat meter G 3/4 “ MESC2 : cold water inlet to second heat meter G 3/4 “ MUSC1: water outlet from first heat meter G 3/4 “ MUSC2: water outlet from second heat meter G 3/4 “ M

AE: hole for cables

CENTRALIZED SYSTEM CONNECTIONSIP : Primary inlet from centralized system G3/4’’ MUP: Primary outlet to centralized system G3/4’’M

APARTMENT SIDE HEATING CONNECTIONS-MONOZONE MODELSMR: heating G 3/4’’ M apartment flowRR: heating G 3/4’’ M apartment return

APARTMENT DHW CONNECTIONSUFS: Cold water outlet G3/4’’ MEFS: Cold water inlet G3/4’’ MESC: hot water inlet G3/4’’ MUSC: hot water outlet G3/4’’ M

AE: hole for cablesV: safety valve discharge

ES : Cold water inlet G 1/2 “ M US: DHW outlet G 1/2 “ M IP : Primary inlet G3/4’’ MUP: Primary outlet G3/4’’M MR: heating G 3/4’’ M flowRR: heating G 3/4’’ M returnVS: safety valve discharge

CENTRALIZED SYSTEM CONNECTIONSIP : Primary inlet from centralized system G3/4’’ MUP: Primary outlet to centralized system G3/4’’M

APARTMENT SIDE HEATING CONNECTIONS-MONOZONE MODELSMR: heating G 3/4’’ M apartment flowRR: heating G 3/4’’ M apartment return

APARTMENT DHW CONNECTIONSUCS: DHW thermostatic outlet UFS: Cold water outletEFS: Cold water inlet

AE: hole for cables

USC ESC UFS EFS

L of the casing 600

Screws seats

Connection kit

Connection kit

Connection kit

Page 37: COMMERCIAL_RANGE_03_13

Technical drawings - graphs - flue systems

37

Technical drawings - graphs - flue systems

Accessories for high output condensing systems Flue Systems - Coaxial flue 38 - Dual flue 39 - Flue accessories for cascade installation 43 - Flexible ducting system 44 Hydraulic accessories 44 Thermoregulation accessories 48 Accessories available as option for Luna SAT 51

37

Page 38: COMMERCIAL_RANGE_03_13

38

Coaxial flue system: Luna Platinum

Coaxial flue system: Luna Duo-Tec MP 50-70 kW

Description Code

Description Code

Description Code

PP coaxial flue pipes with terminal Ø 60/100 L=750 mmsupplied with windproof terminal and sealing collar KHG 714059613 •

PP coaxial flue pipe extension Ø 60/100 L=1000 mm KHG 714059516 •

PP coaxial flue pipe extension Ø 60/100 L=500 mm KHG 714119810 •

PP coaxial 90° bend - Ø 60/100 KHG 714059717 •

PP coaxial 45° bend - Ø 60/100 KHG 714059817 •

Internal sealing collar Ø 100 KHG 714017710 •

PP vertical chimney terminal Ø 80/125(1) KHG 714093510 •

PP reduction from Ø 80/125 to 60/100 KHG 714093910 •

Flat roof tile to be used with a vertical chimney terminal Ø 80/125 KHG 714093610 •

Pitched roof tile to be used with a vertical chimney terminalØ 80/125; it is adjustable from 15° to 45° KHG 714093711 •

PP vertical chimney terminal Ø 80/125 KHG 714093510 •

Flat roof tile to be used with a vertical chimney terminal Ø 80/125 KHG 714093610 •

Pitched roof tile to be used with a vertical chimney terminalØ 80/125; it is adjustable from 15° to 45° KHG 714093711 •

PP coaxial flue pipe with terminal Ø 80/125 L=1000 mmsupplied with wind proof terminal and sealing collar KHG 714088910 •

PP coaxial flue pipe extension Ø 80/125 L=1000 mm KHG 714088511 •

PP coaxial flue pipe extension Ø 80/125 L=500 mm KHG 714088610 •

PP coaxial 90° bend - Ø 80/125 KHG 714088711 •

PP coaxial 45° bend - Ø 80/125 KHG 714088811 •

(1) +KHG 714093910 •

Flue pipe accessories

Coaxial flue system: Luna Platinum - Luna Duo-Tec MP 50-70 kW

Page 39: COMMERCIAL_RANGE_03_13

39

Flue pipe accessories

Coaxial flue system: Luna Duo-Tec MP 90-110 kW

Description Code

PP coaxial flue pipe extension Ø 110/160 L=1000 mm KUG 714133810 •

PP coaxial flue pipe extension Ø 110/160 L=500 mm KUG 714133710 •

PP coaxial 90° bend - Ø 110/160 KUG 714133610 •

PP coaxial 45° bend - Ø 110/160 KUG 714133510 •

PP vertical chimney terminal Ø 110/160 KUG 714133410 •

PP horizontal coaxial chimney Ø 110/160 KUG 714133310 •

Flat roof tile to be used with a verticalchimney terminal Ø 110/160 KHG 714104810 •

Pitched roof tile to be used with a vertical chimney terminalØ 110/160; it is adjustable from 15° to 45° KHG 714104910 •

Dual flue system: Luna Platinum

Description Code

Orientable dual flue system 710268902 •

PP dual flue system Ø 80 it includes: flue reduction,intake connection KHG 714059113 •

PP vertical flue system B23 type installation KHG 714111011 •

PP pipe extension Ø 80 L=1000 mm KHG 714059411 •

PP pipe extension Ø 80 L=500 mm KHG 714059910 •

PP pipe extension Ø 80 L=250 mm 710718301 •

PP 90° bend Ø 80 KHG 714059211 •

PP 45° bend Ø 80 KHG 714059311 •

Dual flue terminal Ø 80 KHG 714010410 •

PP reduction from Ø 80 to Ø 60 KHG 714075610 •

PP pipe extension Ø 60 L=1000 mm KHG 714075310 •

PP pipe extension Ø 60 L=500 mm KHG 714075210 •

PP 90° bend Ø 60 KHG 714075410 •

PP 45° bend Ø 60 KHG 714075510 •

Page 40: COMMERCIAL_RANGE_03_13

40

Flue pipe accessories

Dual flue system: Luna Platinum

Description Code

Dual flue terminal Ø 60 KHG 714037210 •

Pipe Ø 80 centring kit (pack of 5) KHG 714037411 •

Clamp centring kit Ø 80 KHG 714106110 •

Pipe Ø 80 supporting bracket (pack of 5) KHG 714037310 •

Internal sealing collar Ø 80 KHG 714018510 •

External sealing collar Ø 80 KHG 714018411 •

Coaxial vertical chimney terminal Ø 80/125(1) KHG 714093510 •

Dual flue pipes adapter for coaxial chimney Ø 80/125 KHG 714093810 •

Flat roof tile Ø 125 to be used with a vertical chimney terminal KHG 714093610 •

Pitched roof tile Ø 125 to be used with a vertical chimneyterminal; it is adjustable from 15° to 45° KHG 714093711 •

Dual flue system: Luna Duo-Tec MP 50-70 kW - floor standing boilers Power HT 45-65 kW

Description Code

PP pipe extension Ø 80 L=1000 mm KHG 714059411 •

PP pipe extension Ø 80 L=500 mm KHG 714059910 •

PP pipe extension Ø 80 L=250 mm 710718301 •

PP 90° bend Ø 80 KHG 714059211 •

PP 45° bend Ø 80 KHG 714059311 •

Pipe Ø 80 centring kit (pack of 5) KHG 714037411 •

Clamp centring kit Ø 80 KHG 714106110 •

Pipe Ø 80 supporting bracket (pack of 5) KHG 714037310 •

Internal sealing collar Ø 80 KHG 714018510 •

External sealing collar Ø 80 KHG 714018411 •

Flue terminal Ø 80 LSD 790000150 •

Dual flue terminal Ø 80 KHG 714010410 •

(1) +KHG 714093810 •

Page 41: COMMERCIAL_RANGE_03_13

41

Flue pipe accessories

Dual flue system: Luna Duo-Tec MP 50-70 kW

Description Code

PP dual flue system Ø 80 it includes: flue reduction,intake connection KHG 714089010 •

Coaxial vertical chimney terminal 80/125 KHG 714093510 •

Dual flue pipes adapter for coaxial chimney Ø 80/125 KHG 714093810 •

Flat roof tile Ø 125 to be used with a vertical chimney terminal KHG 714093610 •

Pitched roof tile Ø 125 to be used with a vertical chimney terminal; it is adjustable from 15° to 45° KHG 714093711 •

Dual flue system: Luna Duo-Tec MP 90-110 kW

Dual flue system: Luna Duo-Tec MP 90-110 kW - floor standing boilers Power HT 85-150 kW

(1) only for floor standing boilers 85-150 kW

Description Code

PP dual flue kit Ø 110/110 710631401 •

Description Code

PP pipe extension Ø 110 L=1000 mm KUG 714133210 •

PP pipe extension Ø 110 L=500 mm KUG 714133110 •

PP pipe extension Ø 110 L=250mm 710718501 •

PP 90° bend Ø 110 KUG 714133010 •

PP 45° bend Ø 110 KUG 714132910 •

PP reduction kit from Ø 110 to Ø 100(1) KHW 714096910 •

PP vertical chimney terminal Ø 110 KUG 714132810 •

PP horizontal chimney terminal Ø 110 KUG 714132710 •

Flat roof tile to be used with a vertical chimneyterminal Ø 110/160 KHG 714104810 •

Pitched roof tile to be used with a vertical chimney terminal110/160; it is adjustable from 15° to 45° KHG 714104910 •

Dual flue system: floor standing boilers Power HT 45-150 kW

Description Code

Room air indipendent kit ( R.A.I.) Ø 80 for 45-65 kW boilers LSB 710000100 •

Room air indipendent kit ( R.A.I.) Ø 100 for 85-100 kW boilers LSB 710000110 •

Room air indipendent kit ( R.A.I.) Ø 100 for 120-150 kW boilers LSB 710000120 •

Page 42: COMMERCIAL_RANGE_03_13

42

Flue pipe accessories

Dual flue system: floor standing boilers Power HT 230-320 kW

Descrizione Codice

Extension pipe Ø 200 L=500 mm LXO 000971911 •

Extension pipe Ø 200 L=1000 mm LXO 000971928 •

Extension pipe Ø 200 L=2000 mm LXO 000971935 •

87° bend Ø 200 LXO 000971942 •

45° bend Ø 200 LXO 000971959 •

Spacer Ø 200 LXO 000971973 •

Pitched roof tile Ø 200 LXO 000971997 •

SAS flue discharge 200-1B LXO 000688673 •

SAS flue discharge 200-2B LXO 000688680 •

Air grid Ø 200 LXO 000971980 •

87° bend Ø 200 with inspection LXO 000971904 •

Up right duct with inspection hole LXO 000971898 •

SAS vertical chimney terminal Ø 200 LXO 000989527 •

Passing roof Ø 200 LXO 000989497 •

Comburent air filter LXO 000692656 •

Room air indipendent working (WAS 200) LXO 000971881 •

Page 43: COMMERCIAL_RANGE_03_13

43

Flue accessories for cascade installation (for all boilers model, except for floor standing boilers Power HT 230-320 kW)

Description Code

PP flue pipe kit Ø 160 for two boilers 710715201 •

PP flue pipe kit Ø 200 for two boilers 710715601 •

PP flue pipe kit Ø160 for the third boiler 710716301 •

PP flue pipe kit Ø200 for the third boiler 710716401 •

PP 87° bend Ø160 KHW 714097810 •

PP 87° bend Ø200 KHW 714098210 •

PP pipe extension Ø160 L=1000 mm KHW 714097710 •

PP pipe extension Ø200 L=1000 mm KHW 714098110 •

Flue accessories for cascade installation: Luna Platinum - Luna Duo-tec MP 50-70 kW - floor standing boilers Power HT 45-65 kW

Description Code

PP flue pipe kit for two boilers Ø 125 710716801 •

PP flue pipe kit Ø125 for the third boiler 710717701 •

PP shutter kit Ø 110/80 with condensing trap 710682001 •

PP 90° bend Ø 125 KHG 714094410 •

PP 45° bend Ø 125 (pack of 2) KHG 714094510 •

PP pipe extension Ø 125 L=1000 KHG 714094610 •

Flue accessories for cascade installation: Luna Platinum - Luna Duo-tec MP 90-110 kW - floor standing boilers 85-150 kW

Flue accessories for cascade installation: floor standing boilers Power HT 230-320 kW

Description Code

Description Code

PP shutter kit Ø 110/110 with condensing trap 710682101 •

Manifold for 2 boilers in cascade 250 mm LXO 000691444 •

Flue accessories for cascade installation: floor standing boilers Power HT 85-150 kW

Description Code

PP reduction kit from Ø 110 to Ø 100 KHW 714096910 •

Flue pipe accessories

Page 44: COMMERCIAL_RANGE_03_13

44

Description Codice

Manifold pipes for 2 Platinum boilers in cascade- right connection ( with safety device) KHG 714117312 •

Manifold pipes for the 3rd Platinum boiler in cascade- right connection ( with safety device) KHG 714117411 •

Manifold pipes for 2 Platinum boilers in cascade- left connection ( with safety device) KHG 714117512 •

Manifold pipes for the 3rd Platinum boiler in cascade- left connection ( with safety device) KHG 714117611 •

Neutralizer kit for wall hung boilers up to 100 kW KHG 714125610 •

Recharge for neutralizer kit for wall-hung boilers up to 100 kW KHG 714135310 •

Heating systems taps and connection pipes with filter 710931401 •

Flue pipe accessories

Flexible ducting system accessories: wall hung - floor standing boilers 45-65 kW

Description Code

PP flexible pipe Ø 80 L= 1,5 m KHG 714105710 •

PP flexible pipe Ø 80 L= 20 m KHG 714105810 •

PP tee joint Ø 80 with supporting bracket and condensate drainings KHG 714105910 •

PP 90° bend Ø 80 with supporting bracket KHG 714106010 •

Flexible centring kit Ø 80 (pack of 3) KHG 714106210 •

Triple lips gaskets kit Ø 80 (pack of 5) KHG 714111210 •

Hydraulic accessories (WITHOUT SAFETY DEvICE): Luna Platinum

Description Code

Manifold pipes for 2 Platinum boilers in cascade KHG 714117111 •

Manifold pipes for the 3rd Platinum boiler in cascade KHG 714117211 •

Neutralizer kit for wall hung boilers up to 100 kW KHG 714125610 •

Recharge for neutralizer kit for wall-hung boilers up to 100 kW KHG 714135310 •

Heating systems taps and connection pipes with filter 710931401 •

Hydraulic accessories (WITH SAFETY DEvICE): Luna Platinum

Page 45: COMMERCIAL_RANGE_03_13

45

Hydraulic accessories (WITHOUT SAFETY DEvICE): Luna Duo-tec MP single installation

Hydraulic accessories (WITHOUT SAFETY DEvICE): Luna Duo-tec MP for boilers in cascade

Hydraulic accessories (WITHOUT SAFETY DEvICE): Luna Duo-tec MP for boilers in cascade

Single installation for Luna Duo-tec MP from 50 to 70 kW

Single installation for Luna Duo-tec MP from 90 to 110 kW

Boilers in cascade from 50 to 70 kW Coden° of boilers

2 3 4 5

Gas delivery/return manifold kit for individual boiler 50 to 70 kW 710577501 • - 1 pz - 1 pz

Gas delivery/return manifold kit for two boilers 50 to 70 kW 710577701 • 1 pz 1 pz 2 pz 2 pz

Delivery-return-manifolds kit for individual boiler 50 to 70 kW without gas line 710886301 • - 1 pz - 1 pz

Delivery-return-manifolds kit for 2 boilers 50 to 70 kW without gas line 710886501 • 1 pz 1 pz 2 pz 2 pz

Expansion tank connection kit 710583802 • 2 pz 3 pz 4 pz 5 pz

Boiler-manifold connection kit for boilers 50 to 70 kW 710673801 • 2 pz 3 pz 4 pz 5 pz

Boiler-manifold kit for boilers 50 to 70 kW without gas line 710886101 • 2 pz 3 pz 4 pz 5 pz

Flanges and gaskets kit 710582702 • 1 pz 1 pz 1 pz 1 pz

Gas manifolds connection kit for cascade systems 710583201 • - 1 pz 1 pz 2 pz

Insulation kit for individual boiler flow/return manifolds 50 to 70 kW 710587002 • - 1 pz - 1 pz

Insulation kit for two boilers flow/return manifolds 50 to 70 kW 710587502 • 1 pz 1 pz 2 pz 2 pz

Boilers in cascade from 90 to 110 kW Coden° of boilers

2 3 4 5

Gas delivery/return manifold kit for individual boiler 90 to 110 kW 710584601 • - 1 pz - 1 pz

Gas delivery/return manifold kit for two boilers 90 to 110 kW 710584901 • 1 pz 1 pz 2 pz 2 pz

Delivery-return-manifolds kit for individual boiler 90-110 kW without gas line 710886401 • - 1 pz - 1 pz

Delivery-return-manifolds kit for 2 boilers 90-110 kW without gas line 710886601 • 1 pz 1 pz 2 pz 2 pz

Expansion tank connection kit 710583802 • 2 pz 3 pz 4 pz 5 pz

Boiler-manifold connection kit for boilers 90 to 110 kW 710678301 • 2 pz 3 pz 4 pz 5 pz

Boiler-manifold kit for boilers 90-110 kW without gas line 710886201 • 2 pz 3 pz 4 pz 5 pz

Flanges and gaskets kit 710582702 • 1 pz 1 pz 1 pz 1 pz

Gas manifolds connection kit for cascade systems 710583201 • - 1 pz 1 pz 2 pz

Insulation kit for individual boiler flow/return manifolds 90 to 110 kW 710587802 • - 1 pz - 1 pz

Insulation kit for two boilers flow/return manifolds 90 to 110 kW 710588502 • 1 pz 1 pz 2 pz 2 pz

Code

Hydraulic kit with separator for a single boiler from 50 to 70 kW 71163301 •

Code

Gas delivery/return manifold kit for individual boiler 90-110 kW 710584601 •

Boiler-mainfold connection kit for 90 - 110 kW boilers 710678301 •

Expansion tank connection kit 710583802 •

Flanges and gaskets kit 710582702 •

Insulation kit for individual boiler flow/return manifolds 90 - 110 kW boilers 710587802 •

Page 46: COMMERCIAL_RANGE_03_13

46

Hydraulic accessories (WITH SAFETY DEvICE): Luna Duo-tec MP single installation

Hydraulic accessories (WITH SAFETY DEvICE): Luna Duo-tec MP for boilers in cascade

Hydraulic accessories (WITH SAFETY DEvICE): Luna Duo-tec MP for boilers in cascade

Single installation for Luna Duo-tec MP from 50 to 70 kW

Single installation for Luna Duo-tec MP 90 - 110 kW

Boilers in cascade from 50 to 70 kW Coden° of boilers

2 3 4 5

Gas delivery/return manifold kit for individual boiler 50 to 70 kW 710577501 • - 1 pz - 1 pzGas delivery/return manifold kit for two boilers 50 to 70 kW 710577701 • 1 pz 1 pz 2 pz 2 pzDelivery-return-manifolds kit for individual boiler 50 to 70 kW without gas line 710886301 • - 1 pz - 1 pzDelivery-return-manifolds kit for 2 boilers 50 to 70 kW without gas line 710886501 • 1 pz 1 pz 2 pz 2 pzExpansion tank connection kit 710583802 • 2 pz 3 pz 4 pz 5 pzBoiler-manifold connection kit for boilers 50 to 70 kW 710673801 • 2 pz 3 pz 4 pz 5 pzBoiler-manifold kit for boilers 50 to 70 kW without gas line 710886101 • 2 pz 3 pz 4 pz 5 pzFlanges and gaskets kit 710582702 • 1 pz 1 pz 1 pz 1 pzGas manifolds connection kit for cascade systems 710583201 • - 1 pz 1 pz 2 pzInsulation kit for individual boiler flow/return manifolds 50 to 70 kW 710587002 • - 1 pz - 1 pzInsulation kit for two boilers flow/return manifolds 50 to 70 kW 710587502 • 1 pz 1 pz 2 pz 2 pzHydraulic safety devices kit (to be placed in the hydraulic separator connection kit) KHW 714098411 • 1 pz 1 pz 1 pz 1 pz

Boilers in cascade from 90 to 110 kW Coden° of boilers

2 3 4 5

Gas delivery/return manifold kit for individual boiler 90 to 110 kW 710584601 • - 1 pz - 1 pzGas delivery/return manifold kit for two boilers 90 to 110 kW 710584901 • 1 pz 1 pz 2 pz 2 pzDelivery-return-manifolds kit for individual boiler 90-110 kW without gas line 710886401 • - 1 pz - 1 pzDelivery-return-manifolds kit for 2 boilers 90-110 kW without gas line 710886601 • 1 pz 1 pz 2 pz 2 pzExpansion tank connection kit 710583802 • 2 pz 3 pz 4 pz 5 pzBoiler-manifold connection kit for boilers 90 to 110 kW 710678301 • 2 pz 3 pz 4 pz 5 pzBoiler-manifold kit for boilers 90-110 kW without gas line 710886201 • 2 pz 3 pz 4 pz 5 pzFlanges and gaskets kit 710582702 • 1 pz 1 pz 1 pz 1 pzGas manifolds connection kit for cascade systems 710583201 • - 1 pz 1 pz 2 pzInsulation kit for individual boiler flow/return manifolds 90 to 110 kW 710587802 • - 1 pz - 1 pzInsulation kit for two boilers flow/return manifolds 90 to 110 kW 710588502 • 1 pz 1 pz 2 pz 2 pzHydraulic safety devices kit (to be placed in the hydraulic separator connection kit) KHW 714098411 • 1 pz 1 pz 1 pz 1 pz

Code

Hydraulic kit with separator for a single boiler from 50 to 70 kW 71163201 •

Code

Gas delivery/return manifold kit for individual boiler 90-110 kW 710584601 •Boiler-mainfold connection kit for 90 - 110 kW boilers 710678301 •Expansion tank connection kit 710583802 •Flanges and gaskets kit 710582702 •Insulation kit for individual boiler flow/return manifolds 90 - 110 kW boilers 710587802 •Hydraulic safety devices kit (to be placed in the hydraulic separator connection kit) KHW 714098411 •

Hydraulic accessories (WITHOUT SAFETY DEvICE): Luna Duo-tec MP for boilers in cascadeHydraulic separators

Code

Connection to hydraulic separator kit 8,5 m3/h 710686501 •manifolds insulation kit for 8,5 m3/h hydr. separator 710687901 •Screws and gaskets for 8,5 m3/h hydr. separator LSD 790000440 •Hydraulic separator HS 8,5 of 8,5 m3/h - 2“ threaded connectors LSD 790000310 •

Connection to hydraulic separator kit 18 m3/h DN65 710687501 •Manifolds insulation kit for 18 m3/h DN65 hydraulic separator 710688901 •Screws and gaskets for 18 m3/h DN65 hydr. separator LSD 790000430 •Hydraulic separator 18 m3/h DN65 LSD 790000320 •

Connection to hydraulic separator kit 28 m3/h DN80 710687601 •Manifolds insulation kit for 28 m3/h DN80 hydraulic separator 710689201 •Screws and gaskets for 28 m3/h DN80 hydr. separator LSD 790000420 •Hydraulic separator 28 m3/h DN80 LSD 790000330 •

Page 47: COMMERCIAL_RANGE_03_13

47

Hydraulic accessories: Luna Duo-tec MP Description Code

Hydraulic safety devices kit (available as optional) KHW 714098411 •

Neutralizer kit for wall hung boilers up to 100 kW KHG 714125610 •

Recharge for neutralizer kit for wall-hung boilers up to 100 kW KHG 714135310 •

Hydraulic separator HS 56 of 56 m³/h - Ø 100 flanged connectors LSD 790000340 •

Neutralizer kit for wall hung boilers up to 350 kW KHG 714125710 •

Recharge for neutralizer kit for wall-hung boilers up to 350 kW KHG 714135410 •

Hydraulic accessories (WITH SAFETY DEvICE): Luna Duo-tec MP for boilers in cascadeHydraulic separators

Code

Connection to hydraulic separator kit 8,5 m3/h (with safety devices connections) 710578401 •

manifolds insulation kit for 8,5 m3/h hydr. separator 710640601 •

Screws and gaskets for 8,5 m3/h hydr. separator LSD 790000440 •

Hydraulic separator HS 8,5 of 8,5 m3/h - 2” threaded connectors LSD 790000310 •

Connection to hydraulic separator kit 18 m3/h DN65 (with safety devices connections) 710579001 •

Manifolds insulation kit for 18 m3/h DN65 hydraulic separator 710642201 •

Screws and gaskets for 18 m3/h DN65 hydr. separator LSD 790000430 •

Hydraulic separator 18 m3/h DN65 LSD 790000320 •

Connection to hydraulic separator kit 28 m3/h DN80 (with safety devices connections) 710579301 •

Manifolds insulation kit for 28 m3/h DN80 hydraulic separator 710642801 •

Screws and gaskets for 28 m3/h DN80 hydr. separator LSD 790000420 •

Hydraulic separator 28 m3/h DN80 LSD 790000330 •

Description Code

Brazed exchanger 50- 100kW 711261001 •

Brazed exchanger 50- 100kW 711261101 •

23P inspectable exchanger 200kW 711196001 •

27P inspectable exchanger 250kW 711196101 •

33P inspectable exchanger 300kW 711196201 •

37P inspectable exchanger 350kW 711196301 •

41P inspectable exchanger 400kW 711196401 •

Safety devices manifold kit LSD 790000580 •

Manifold kit L=495 LSD 790000120 •

Hydraulicaccessories:LunaDuo-tecMP50-110kW-floorstandingboilersPower HT45-430 kW

Page 48: COMMERCIAL_RANGE_03_13

48

Description Code

Mixing valve motor KHG 714078511 •

Mixing valve G1” KHG 714078310 •

Mixing valve G1/2” KHG 714078610 •

Mixing valve G3/4” KHG 714078710 •

Flow/return sensor for controller for boilersin cascade and mixing system KHG 714078810 •

Flow sensor for clip-in module KHG 714078910 •

Hot water temperature sensor KHG 714076810 •

Description Code

Outdoor sensor THINK 710487302 •

Outdoor sensor THINK (wireless)* 710302701 •

Interface kit for remote control THINK - 3 leds 710234003 •

Interface kit for remote control THINK - 5 leds wireless 710244103 •

Wireless aerial THINK 710234302 •

Accessories for the thermoregulation, programming, setting and digital control - Luna Platinum - Luna Duo-tec MP - floorstandingboilersPowerHT45-150kW

Accessories for the thermoregulation, programming, settingand digital control - Luna Platinum

* wireless model to be ordered with the interface kit for remote control THINK - 5 leds (710244103 •) or the wireless aerial THINK (710234302 •)

Hydraulicaccessories:floorstandingboilersPowerHT45-150kW

Hydraulic accessories for twin boilers in cascade Power HT 230-320

Description Code

Manifold pipes single boiler/last boiler KHW 714104210 •

Boiler-manifold pipe hydraulic connection KHW 714104311 •

Manifold pipes boilers in cascade (45 cm between the boilers) KHW 714099010 •

Manifold pipes boilers in cascade (2 cm between the boilers) KHW 714103611 •

Hydraulic connection for 2nd pump (1) KHW 714098612 •

Pump for hydraulic connection accessories 711187201 •

Description Code

Connection kit 2 boilers in cascade KB1 – mod. HT 1.230 LXO000692632 •

Connection kit 2 boilers in cascade KB2– mod. HT 1.280-1.320 LXO000692649 •

(1) the pump for hydraulic connection accessories is compulsory (711187201 •)

Page 49: COMMERCIAL_RANGE_03_13

49

Description Code

Room thermostat THINK 710106106 •

Room thermostat (wireless) THINK* 710304405 •

Room thermostat with timer THINK 710298006 •

Room thermostat with timer THINK – wireless* 710297905 •

Programmable clip-in module THINK 710034504 •

Flow sensor for clip-in module THINK KHG 714078910 •

Programmable external module THINK 710503705 •

Hot water temperature sensor KHG 714076810 •

Interface kit for boilers in cascade THINK 710440803 •

Climate controller kit for mixing zones THINK 710519903 •

Sensor for solar controller LNC 710000040 •

Description Code

Outdoor sensor THINK 710487302 •

Outdoor sensor THINK (wireless)* 710302701 •

Wireless aerial THINK 710234302 •

Programmable clip-in module THINK 710034504 •

Programmable external module THINK 710503705 •

Hot water temperature sensor KHG 714076810 •

Remote control THINK 710244203 •

Remote control THINK (wireless) 710244303 •

Climate controller kit for mixing zones THINK 710519903 •

Interface kit for boilers in cascade THINK 710440803 •

Sensor for solar controller LNC 710000040 •

* wireless model to be ordered with the interface kit for remote control THINK - 5 leds (710244103 •) or the wireless aerial THINK (710234302 •)

Accessories for the thermoregulation, programming, setting and digital control - Luna Platinum

Accessories for the thermoregulation, programming, setting and digital control - Luna Duo-tec MP

Page 50: COMMERCIAL_RANGE_03_13

50

Description Code

Outdoor sensor 710487302 •

Remote controller and climatic regulator KHG 714072612 •

Boiler interface for mixing systems with two different temperatures zones KHG 714077913 •

Bus interface for climatic regulators for boilers in cascade KHG 714078013 •

Boiler control interface 0-10 V KHG 714107612 •

Temperature regulator for mixing systems, it includes a temperature sensor KHG 714078112 •

Cascade controller, it includes a temperature sensor KHG 714078212 •

Room sensor: it can be installed only with climatic regulator for mixing system KHG 714078410 •

Installation box for RVA controllers KHG 714096610 •

Hot water temperature sensor for climatic regulator for boilers in cascade KHG 714079010 •

Description Code

Outdoor sensor THINK 710487302 •

Interface kit for boilers in cascade 710440803 •

External tank sensor L=2 m LSX 710000010 •

External tank sensor L=6 m LSX 710000020 •

Accessory for managing mixing systems or solar panels LSX 710000030 •

Climate controller kit for mixing zones THINK 710519903 •

Description Code

LPG conversion kit for LUNA DUO-TEC MP 1.50 710718603 •

LPG conversion kit for LUNA DUO-TEC MP 1.60 710718702 •

LPG conversion kit for LUNA DUO-TEC MP 1.70 710718802 •

LPG conversion kit for LUNA DUO-TEC MP 1.90 710718902 •

LPG conversion kit for LUNA DUO-TEC MP 1.110 710719002 •

Accessories for the thermoregulation, programming, settinganddigitalcontrol-floorstandingboilers45-150kW

Accessories for the thermoregulation, programming, settinganddigitalcontrol-floorstandingboilers230-320kW

LPG conversion kit: Luna Duo-tec MP

Page 51: COMMERCIAL_RANGE_03_13

51

M-BUS controlFirst flow meter - mod. R/1-MB, RP/1-MB, R2Z-MB - RPE-MB, RPB - MB KSV 714116410 • First flow meter - mod. RS-MB, RSP-MB, RS2Z-MB KSV 714116510 • First or second flow meter - mod. RH-MB, RH1-MB, R2H-MB KSV 714116610 • First or second flow meter - mod. RPH-MB KSV 714116710 • Second flow meter - mod. RP/1-MB KSV 714118210 • Second flow meter - mod. R/1-MB, R2Z-MB - RPE-MB, RPB-MB KSV 714118310 • First or second flow meter RHG1-MB 1’’ KSV 714125010 • First or second flow meter RHG1-MB 3/4’’ KSV 714125210 • M-BUS flow meter - Luna Sat RC-MB KSV 714134310 •

Code

WIRELESS controlFirst flow meter - mod. R/1-RP/1-R2Z - RPE - RPB KSV 714102511 • First flow meter - mod. RS-RSP-RS2Z KSV 714102611 • Second flow meter - mod. RP/1 KSV 714106312 • Second flow meter - mod. R/1-R2Z - RPE - RPB KSV 714110111 • Flow meter - mod. RA-RA2Z KSV 714110011 • First or second flow meter - mod. RH -RH1- R2H KSV 714114511 • First or second flow meter - mod. RPH KSV 714114611 • First or second flow meter RHG1 1’’ KSV 714124910 • First or second flow meter RHG1 3/4’’ KSV 714125111 • Flow meter - Luna Sat RC KSV 714131310 •

Code

ThermoregulationOutdoor sensor 710487302 • Room thermostat (RT) KHG 714062810 • Remote control and chronostat (mod. R2Z, RS, RSP, RS2Z, RA, RA2Z, RPE, RPEH - wireless and M-BUS) KSV 714109511 • Digital chronostat (mod. R/1, RP1) KHG 714086711 •

Code

Accessories available as optionLuna SAT

WIRELESS data transmissionNetwork node KSV 714102711 • Network node with gateway KSV 714103011 • Network node with gateway for transmission via GSM KSV 714102811 • Remote reader device KSV 714102911 • Software ACS 26 KSV 714108611 • Connecting cable PC-network node for network note with gateway KSV 714116110 • Wireless impulse adaptor AEW36.2 KSV 714117710 •

Code

M-BUS data transmissionImpulse adaptor AEW 310.2 M-BUS KSV 714116210 • Connection cable heat meter M-BUS KSV 714116310 • M-BUS central unit made of 250 loads KSV 714136910 • M-BUS central unit made of 120 loads KSV 714137010 • M-BUS central unit made of 60 loads KSV 714137110 • M-BUS central unit made of 20 loads KSV 714137210 • M-BUS central unit made of 60 loads for GSM transmission, e-mail KSV714146510 •Extension to 120 loads for GSM central unit, e-mail KSV714146610 •Extension to 250 loads for GSM central unit, e-mail KSV714146710 •Software for local reading of the GSM central unit, e-mail KSV714146810 •

Code

Page 52: COMMERCIAL_RANGE_03_13

52

Accessories available as optionLuna SAT

Heat meter UH50 G1 ¼’’ KSV 714117810 • Heat meter UH50 G2’’ KSV 714117910 • Heat meter UH50 G1’’ KSV 714144810 •Heat meter UH50 DN 50 KSV 714144910 •Heat meter UH50 DN 65 KSV 714145010 •Heat meter UH50 DN 80 KSV 714145110 •Wireless interface UH50 for ultrasonic heat-meter KSV 714121710 • Well for NTC sensor (½” and ¾”) for UH50 KSV 714127310 • Well for NTC sensor G1/2’’ for UH50 models DN50-DN60-DN80 (output up to 6 m3/h) KSV 714146910 •Additional well for NTC sensor G 1/2” for UHG50 models G2” DN50-DN65-DN80 (output up to 10 m3/h) KSV 714127410 • M-BUS interface UH50 for ultrasonic heat-meter KSV 714121810 • Complete template for Luna Sat RH1 KSV 714122310 • By-pass for Luna Sat RC KSV 714136310 • By-pass ( inversione) for Luna Sat RC KSV 714139610 •Heating hydraulic proof for Luna Sat RC KSV 714136410 • Sanitary hydraulic proof for Luna Sat RC KSV 714136510 • 2L Sanitary expansion vessel for Luna Sat R60WH KSV 714110410 •4L Sanitary expansion vessel (Luna Sat B60) KSV 714110410 •GSM modem for DIN frame KSV 714140810 •

Code

Equipment (for all wireless/M-BUS models)(to be ordered for RH model)

Other accessories

Hydraulic equipment for Luna Sat heating only models R/1, RP/1, RH, RH1, RPH, RPB, RPE, R2H (x2), RPEH KSV 714120911 • Hydraulic equipment for Luna Sat heating and DHW production model RS, RSP KSV 714121011 • Hydraulic equipment for Luna Sat models R2Z, RA, RA2Z KSV 714121110 • Hydraulic equipment for Luna Sat heating / DHW production model RS2Z KSV 714121210 • Hydraulic equipment for 2 flow meters for Luna Sat R/1, RP/1, RPB, RPE models KSV 714121310 • Hydraulic equipment for 2 flow meters for Luna Sat RH, RPH, R2H. RPEH models KSV 714121410 •

Code

Mounting accessories (all casings has built-in taps except mod. RH and RHG1)

Single zone casing - for R/1, RP/1, RPB, RPE, RSP, RA KSV 714145310 • 2 zones casing - for R2Z, RS2Z, RA2Z KSV 714145410 • Casing for RH 650x650 mm (without taps; cod. KSV 714120911 • to be ordered) KSV 714117011 • Casing for R2H KSV 714145510 • Casing for RHG1 (without taps) KSV 714124010 • Casing for RPH - RPEH KSV 714145610 • Casing for RC KSV 714131011 • Casing for RST KSV 714141210 • Casing for RP-SP KSV 714142010 •

Code

CylinderLuna SAT B60 cylinder KSV 71410841

Code

Accessories for Luna Sat Rack (3 modules)

Accessories for Luna Sat Rack (4 modules)

Code

Code

3 Luna Sat RC – Rack casing KSV 714142311 • Flow/return collectors 3 Luna Sat RC- Rack KSV 714142610 • DHW collector kit 3 Luna Sat RC- Rack KSV 714142810 •DCW collector kit 3 Luna Sat RC- Rack KSV 714142910 •Collector kit for the 3rd flow meter 3 Luna Sat RC- Rack KSV 714143010 •

4 Luna Sat RC – Rack case KSV 714142411 • Flow/return collectors 4 Luna Sat RC- Rack KSV 714142710 • DHW collector kit 4 Luna Sat RC- Rack KSV 714143110 • DCW collector kit 4 Luna Sat RC- Rack KSV 714143210 • Collector kit for the 3rd flow meter 3 Luna Sat RC- Rack KSV 714143310 •

Page 53: COMMERCIAL_RANGE_03_13

53

Products technical data

High output condensing gas boilers 54

Page 54: COMMERCIAL_RANGE_03_13

54

PR

OD

UC

T

H

eat i

nput

He

at o

utpu

t

Effic

ienc

y (Hi

)

Max

imum

Out

put

no

t wor

king

Max

imum

out

put

Min

imum

Out

put

Pow

er co

nsum

ptio

n

92/4

2/EE

C

bu

rner

M

AX.

MIN

. M

AX.

MIN

. av

erag

e 30

%

star

s co

mbust

ion c

him

ney

radi

atin

g ch

imne

y flu

e CO

2 O

2 ex

ceed

ing

flue

flue

CO2

O2

exce

eding

flu

e no

min

al n

omin

al

Cert

ifica

te

tem

p.

nu

mbe

r ef

ficie

ncy

heat

he

at

heat

te

mp.

ai

r m

ass

tem

p.

air

mas

s bo

iler

pum

p EE

C

Pn 7

0°C

92

/42/

EEC

lo

sses

lo

sses

lo

sses

m

ax

and

flow

/rat

e m

ax

and

flow

/rat

e

kW

kW

kW

kW

%

%

%

%

%

%

°C

%

%

%

kg

/s

°C

%

%

%

kg/s

W

W

N

r.

LUN

A P

LATI

NU

M 1

.12

12,4

2,

1 12

2

97,7

10

8 HHHH

98

,2

1,8

0,5

0,1

75

9,0

4,8

30

0,00

6 55

9,

0 4,

8 30

0,

001

95

75

0085

CM

0140

LUN

A P

LATI

NU

M 1

.18

17,4

2,

1 16

,9

2 97

,6

108

HHHH

98

,1

1,9

0,5

0,1

75

9,0

4,8

30

0,00

8 55

9,

0 4,

8 30

0,

001

110

75

0085

CM

0140

LUN

A P

LATI

NU

M 1

.24

24,7

2,

5 24

2,

4 97

,6

107,

6 HHHH

98

,1

1,9

0,5

0,1

80

9,0

4,8

30

0,01

1 55

9,

0 4,

8 30

0,

001

120

75

0085

CM

0140

LUN

A P

LATI

NU

M 1

.32

33

3,3

32

3,2

97,6

10

7,6

HHHH

98

,1

1,9

0,5

0,1

80

9,0

4,8

30

0,01

5 55

9,

0 4,

8 30

0,

002

130

75

0085

CM

0140

LUN

A D

UO

-TEC

MP

1.50

46

,3

5,1

45

5 97

,4

107,

6 HHHH

98

,0

2,0

0,6

0,1

92

9,0

4,8

30

0,02

1 58

8,

5 5,

7 38

0,

002

190

115

0085

CM

0128

LUN

A D

UO

-TEC

MP

1.60

56

,6

6,3

55

6,1

97,2

10

7,6

HHHH

97

,8

2,2

0,6

0,1

96

9,0

4,8

30

0,02

6 59

9,

0 4,

8 30

0,

003

210

120

0085

CM

0128

LUN

A D

UO

-TEC

MP

1.70

66

,9

7,4

65

7,2

97,2

10

7,6

HHHH

97

,8

2,2

0,6

0,1

76

9,0

4,8

30

0,03

1 55

8,

5 5,

7 38

0,

004

210

125

0085

CM

0128

LUN

A D

UO

-TEC

MP

1.90

87

,4

9,7

85

9,4

97,3

10

7,3

HHHH

97

,9

2,1

0,6

0,1

75

9,0

4,8

30

0,04

0 55

8,

5 5,

7 38

0,

005

275

165

0085

CM

0128

LUN

A D

UO

-TEC

MP

1.11

0 10

4,9

11,7

10

2 11

,4

97,2

10

7,4

HHHH

97

,8

2,2

0,6

0,1

74

9,2

4,5

27

0,04

7 55

9,

0 4,

8 30

0,

005

320

170

0085

CM

0128

LUN

A H

T 1.

350

34,8

15

33

,9

14,5

97

,3

107,

6 HHHH

97

,9

2,1

0,6

0,1

72

8,7

5,4

34

0,01

6 55

8,

4 5,

9 39

0,

007

45

- 00

85B

P02

56

LUN

A H

T 1.

450

46,4

15

45

14

,5

97,3

10

7,6

HHHH

97

,9

2,1

0,6

0,1

74

8,7

5,4

34

0,02

2 55

8,

4 5,

9 39

0,

007

75

- 00

85B

P02

56

LUN

A H

T 1.

450

P 46

,4

15

45

14,5

97

,3

107,

6 HHHH

97

,9

2,1

0,6

0,1

74

8,7

5,4

34

0,02

2 55

8,

4 5,

9 39

0,

007

175

100

0085

BP

0256

LUN

A H

T 1.

550

56,7

16

55

15

,5

97,4

10

7,5

HHHH

98

,0

2,0

0,6

0,1

78

8,7

5,4

34

0,02

7 55

8,

4 5,

9 39

0,

008

80

- 00

85B

P02

56

LUN

A H

T 1.

650

67

20

65

19,3

97

,3

107,

6 HHHH

97

,9

2,1

0,6

0,1

75

8,7

5,4

34

0,03

2 55

8,

4 5,

9 39

0,

010

125

- 00

85B

P02

56

LUN

A H

T 1.

850

87,2

26

,4

85

25,7

97

,5

107,

3 HHHH

98

,1

1,9

0,6

0,1

75

8,7

5,4

34

0,04

1 55

8,

4 5,

9 39

0,

013

150

- 00

85B

P02

56

LUN

A H

T 1.

1000

10

5 29

,8

102

29

97,4

10

7,4

HHHH

98

,0

2,0

0,6

0,1

74

8,7

5,4

34

0,05

0 55

8,

4 5,

9 39

0,

015

200

- 00

85B

P02

56

PO

WER

HT

1.45

0 46

,4

12,2

45

11

,8

97,3

10

7,6

HHHH

97

,9

2,1

0,6

0,1

75

8,7

5,4

34

0,02

2 55

8,

4 5,

9 39

0,

006

900

- 00

85B

Q00

55

PO

WER

HT

1.65

0 67

13

,8

65

13,4

97

,3

107,

6 HHHH

97

,9

2,1

0,6

0,1

75

8,9

5,0

31

0,03

1 55

8,

4 5,

9 39

0,

007

110

- 00

85B

Q00

55

PO

WER

HT

1.85

0 87

,2

33,1

85

32

,2

97,5

10

7,3

HHHH

98

,1

1,9

0,6

0,1

78

8,7

5,4

34

0,04

1 56

8,

6 5,

6 36

0,

016

100

- 00

85B

Q00

55

PO

WER

HT

1.10

00

102,

7 36

,8

100

35,8

97

,4

107,

4 HHHH

98

,0

2,0

0,6

0,1

80

8,7

5,4

34

0,04

9 57

8,

6 5,

6 36

0,

018

160

- 00

85B

Q00

55

PO

WER

HT

1.11

50

115

40

115

39

97,4

10

7,5

HHHH

98

,0

2,0

0,6

0,1

72

8,7

5,4

34

0,05

4 55

8,

4 5,

9 39

0,

019

128

- 00

85B

Q00

55

PO

WER

HT

1.12

00

123,

2 40

12

0 39

97

,4

107,

5 HHHH

98

,0

2,0

0,6

0,1

77

8,7

5,4

34

0,05

8 58

8,

4 5,

9 39

0,

019

135

- 00

85B

Q00

55

PO

WER

HT

1.15

00

154

41,5

15

0 40

,4

97,4

10

7,2

HHHH

98

,0

2,0

0,6

0,1

75

8,7

5,4

34

0,07

3 58

8,

4 5,

9 39

0,

020

235

- 00

85B

Q00

55

PO

WER

HT

1.23

0 21

5 35

21

0,1

33,5

97

,3

105,

4 HHHH

97

,9

1,7

2,5

0,0

61

9,3

4,3

26

0,09

7 57

9,

3 4,

3 26

0,

016

330

- 00

85C

L007

2

PO

WER

HT

1.28

0 26

0 42

25

4,5

40,2

97

,4

105,

6 HHHH

98

,0

1,7

2,5

0,0

61

9,3

4,3

26

0,11

8 57

9,

3 4,

3 26

0,

019

350

- 00

85C

L007

2

PO

WER

HT

1.32

0 30

0 48

29

4 45

,9

97,4

10

5,7

HHHH

98

,0

1,7

2,6

0,0

61

9,3

4,3

26

0,13

6 57

9,

3 4,

3 26

0,

021

410

- 00

85C

L007

2

DAT

A R

EFER

RED

TO

PO

WER

HT-

A:

SOO

N A

VAIL

AB

LE

Products technical data – High output condensing boilers

Page 55: COMMERCIAL_RANGE_03_13

55

Page 56: COMMERCIAL_RANGE_03_13

QualityEnvironment

Safety

QualityEnvironment

Safetyare Baxi strategic aims and the awarded certifications

ensure compliance with the specific regulations

The Company assumes no responsibility for any possible contents mistakes, and reserves the right to make changes in products, due to technical or commercial demands, at any time without notice.

Baxi S.p.A. 02-13 (E)

36061 BASSANO DEL GRAPPA (VI) - ITALYVia Trozzetti, [email protected]