1 PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc ION-M Optical DAS Equipment
Transcript
  • 5/24/2018 CommScope ION-M DAS Training

    1/108

    1

    PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    ION-M Optical DAS Equipment

  • 5/24/2018 CommScope ION-M DAS Training

    2/108

    2

    PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    ION-M Fiber Optical

    Distributed Antenna System

  • 5/24/2018 CommScope ION-M DAS Training

    3/108

    3

    PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    ION-M Basic Components

    Optical Master Unit

    Optical Remote Unit

    Single-Mode Optical Fiber Backbone

    Antennas

    Operation & Maintenance Platform

    RMC600, Keyboard and Monitor

  • 5/24/2018 CommScope ION-M DAS Training

    4/108

    4

    PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    ION-M Master

    Integral Rack Mount Controller

    Optical Transceiver

    Optional Redundant Power Supplies

    Configurable Dry Contact Alarms

    RF Distribution for Flexible Configurations

    Multiple Frequency Bands

    Independent Sectorization

  • 5/24/2018 CommScope ION-M DAS Training

    5/108

    5

    PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    ION-M Master

  • 5/24/2018 CommScope ION-M DAS Training

    6/108

    6

    PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    ION-M Master Front View

  • 5/24/2018 CommScope ION-M DAS Training

    7/1087

    PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    ION-M Master Rear View

  • 5/24/2018 CommScope ION-M DAS Training

    8/1088

    PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    2 OTRx Subrack

    Used for Multi-Operator and/or Multi-Band systems

    Supports 2 OTRxs, 3 BTS Connect Modules per OTRx

    BTS Connect Modules used for RF Distribution to OTRx Module Height is 3HU

  • 5/24/2018 CommScope ION-M DAS Training

    9/1089

    PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    3 OTRx Subrack

    Used for single or multi operators in single band or multi band applications

    Optional space for power supply

    SAB can be included in this subrack Supports 1 BTS Connect Module per OTRx

    Height is 3HU

  • 5/24/2018 CommScope ION-M DAS Training

    10/10810

    PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    4 OTRx Subrack

    Used for single or multi operators in single or multi band applications

    Optional space for power supply

    Supports 1 to 4 BTS Connect Modules Height is 3HU

  • 5/24/2018 CommScope ION-M DAS Training

    11/108

    11PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    Optical Transceiver SMRU (OTRx)

    E-2000/APC optical connector.

    1310/1550 nm for downlink/uplink paths, respectively.

    Converts RF to optic

    3 RF inputs for differentfrequency bands.

    Auto-leveling for optical lossup to 10 dB

    OPTO

    Optical Transceiver

  • 5/24/2018 CommScope ION-M DAS Training

    12/108

    12PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    System Diagram: Star Configuration

    Standard system configuration

    One OTRx for each Remote Unit

    Separate optical fiber for each Remote Unit

    161988: OTRx 4-21

    E

    O

    O

    E

    1550 nm

    1310 nm

    DL

    UL

    360-500

    800-1000

    1800-2200

    360-500

    800-1000

    1800-2200

    MMR Remote

    161988: OTRx 4-21

    E

    O

    O

    E

    1550 nm

    1310 nm

    DL

    UL

    360-500

    800-1000

    1800-2200

    360-500

    800-1000

    1800-2200

    MMR Remote

    161988: OTRx 4-21

    E

    O

    O

    E

    1550 nm

    1310 nm

    DL

    UL

    360-500

    800-1000

    1800-2200

    360-500

    800-1000

    1800-2200

    MMR Remote

    161988: OTRx 4-21

    E

    O

    O

    E

    1550 nm

    1310 nm

    DL

    UL

    360-500

    800-1000

    1800-2200

    360-500

    800-1000

    1800-2200

    MMR Remote

  • 5/24/2018 CommScope ION-M DAS Training

    13/108

    13PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    Mini Master Controller (MMC plus)

  • 5/24/2018 CommScope ION-M DAS Training

    14/108

    14PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    ION-M Display and Keyboard Equipment

  • 5/24/2018 CommScope ION-M DAS Training

    15/108

    15PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    Leveling Adapter

    The front panel RF connectors provideaccess to the DL and UL RF signals thatwould be input to the OTRx.

    Input signal levels can be adjusted prior tothe OTRx and measured through theleveling adapter.

    The leveling adapter is used in place of theOTRx to aid in leveling the downlink path.

    The front panel interface connectors areSMA-Female.

  • 5/24/2018 CommScope ION-M DAS Training

    16/108

    16PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    Duplexers

    Mounted in the rear of the subrack.

    7612767-00 Duplexer Passive 698-716 776-787 728-757

    7597010-00 Duplexer Passive 806-824 851-869

    7597012-00 Duplexer Passive 824-849 869-894

    7597020-00 Duplexer Passive 880-915 925-960

    7597024-00 Duplexer Passive 1850-1915 1930-1995

    7543460-00 Duplexer Passive 1710-1755 2110-2155

    TX/RX

    TX

    RX

  • 5/24/2018 CommScope ION-M DAS Training

    17/108

    17PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    Duplexer Unit

  • 5/24/2018 CommScope ION-M DAS Training

    18/108

    18PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    Indoor Racks 24HU, 38HU, 47HU

    24 HU

    H x W x D: 1260 x 605 x 700 mm (50 x23.8 x 27.6)

    Weight: 82 kg, 180 lbs

    38 HU

    H x W x D: 1860 x 605 x 700 mm

    (73 x2 3.8 x 27.6)

    Weight: 109 kg, 240 lbs

  • 5/24/2018 CommScope ION-M DAS Training

    19/108

    19PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    ION-M Rack Fan Sets

  • 5/24/2018 CommScope ION-M DAS Training

    20/108

    20PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    ION-M IndoorRack Installation

  • 5/24/2018 CommScope ION-M DAS Training

    21/108

    21PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    ION-M IndoorRack Installation

  • 5/24/2018 CommScope ION-M DAS Training

    22/108

    22PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    ION-M IndoorRack Installation

  • 5/24/2018 CommScope ION-M DAS Training

    23/108

    23PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    ION-M Indoor Rack Anchorage Kit

  • 5/24/2018 CommScope ION-M DAS Training

    24/108

    24PRIVATE AND CONFIDENTIAL 2012 CommScope, Inc

    ION-M OutdoorRack

  • 5/24/2018 CommScope ION-M DAS Training

    25/108

    25

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    Outdoor Rack Options

  • 5/24/2018 CommScope ION-M DAS Training

    26/108

    26

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Rack Power Supply Unit

  • 5/24/2018 CommScope ION-M DAS Training

    27/108

    27

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Rack 4 Power Supply Unit

  • 5/24/2018 CommScope ION-M DAS Training

    28/108

    28

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Rack 8 Power Supply Unit

  • 5/24/2018 CommScope ION-M DAS Training

    29/108

    29

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    8 Power Supply Unit

  • 5/24/2018 CommScope ION-M DAS Training

    30/108

    30

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    Power Supply Unit (PSU)

    7159468: 85 to 264 VAC Input

    7159467: 36 to 76 VDC Input

    Output is 12VDC, 150W

    One PSU supports up to 7 OTRxs

    N+1 Redundancy is provided when using one PSU more

    than required

    U1

    U1 Test+

    -

    Power Supply

  • 5/24/2018 CommScope ION-M DAS Training

    31/108

    31

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    Power Supply Subrack4 PSU

    7163420: Supports 1 to 4 AC PSUs and RAB

    7163421: Supports 1 to 4 DC PSUs and RAB

    Supports 1 to 4 OTRx subracks

    Height is 3 HU

  • 5/24/2018 CommScope ION-M DAS Training

    32/108

    32

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    Power Supply Subrack8 PSU

    7163765: Supports 1 to 8 DC PSUs and RAB

    Supports 1 to 8 OTRx subracks

    7163764: Supports 1 to 8 AC PSUs and RAB

    Height is 6HU

  • 5/24/2018 CommScope ION-M DAS Training

    33/108

    33

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Indoor Rack Power Cable Installation

  • 5/24/2018 CommScope ION-M DAS Training

    34/108

    34

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Rack AC Power Terminal Block Connections

  • 5/24/2018 CommScope ION-M DAS Training

    35/108

    35

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Rack DC Power Terminal Block Connections

  • 5/24/2018 CommScope ION-M DAS Training

    36/108

    36

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Master Cable Routing

  • 5/24/2018 CommScope ION-M DAS Training

    37/108

    37

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Outdoor Rack Power Cable Installation

  • 5/24/2018 CommScope ION-M DAS Training

    38/108

    38

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Multi Rack Interconnect Cable Installation

  • 5/24/2018 CommScope ION-M DAS Training

    39/108

    39

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Installation Electrical Installation

  • 5/24/2018 CommScope ION-M DAS Training

    40/108

    40

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Rack Power Loading

  • 5/24/2018 CommScope ION-M DAS Training

    41/108

    41

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    RF Combining Section

  • 5/24/2018 CommScope ION-M DAS Training

    42/108

    42

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    4-Way Combiners

    ID 7161269-00 : 698-960 MHz

    ID 7160615 : 1710-1990 MHz

    ID 7160614 : 1920-2170 MHz

    Combines four input into a common output. Typically a

    duplexer is required to separate UL/DL.

    The signal level into each port can be adjusted with avariable attenuator 0-10 dB typically.

    The front panel interface connectors are SMA-Female

    Max. input power per port: 27.5dBm

    RF Probe

    1

    4-Way Combiner

    2

    3

    4

  • 5/24/2018 CommScope ION-M DAS Training

    43/108

    43

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    4-Way Splitters

    Splits a single input to four outputs. Typically a

    duplexer is required to separate UL/DL.

    The front panel interface connector is SMA-

    Female

    1

    IN

    1606414-Way Splitter

    2

    3

    4

    7612781-01 Splitter Rear Mount 4-way 698-960 6.5dB IL

    7615789-00 Splitter Rear Mount 4-way 1710-2170 6.5dB IL

    7614494-00 Splitter 3HU 4-way 698-960, 10-20 dB IL

    7163801 Splitter 3HU 4-way 1710-2170, 12-21 dB IL

    7618755 Front Panel Kit for front mounting

    4-way Splitter

    with Att.

    d

    B

    dB

    d

    B

    d

    B

  • 5/24/2018 CommScope ION-M DAS Training

    44/108

    44

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    BTS Connect 2 Port 698-960 MHz ID# 7614493-00

  • 5/24/2018 CommScope ION-M DAS Training

    45/108

    45

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    BTS Connect 3 Port 1710-2170 MHz ID# 7164621

  • 5/24/2018 CommScope ION-M DAS Training

    46/108

    46

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    BTS Connect 4 Port 698-960,1700-2200 MHz ID# 7546702-02

  • 5/24/2018 CommScope ION-M DAS Training

    47/108

    47

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    BTS Connect Attenuators

  • 5/24/2018 CommScope ION-M DAS Training

    48/108

    48

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    Intelligent Point of Interface (i-POI)

    UL1UL2

    DL/

    UL1

    DL/

    UL2

    UL1 DIVUL2 DIV

    UL1,2

    UL DIV1,2

    DL 1,2

    DL 1,2

    UL1,2

    DL1,2DL1,2

    UL DIV1,2

    E911-UL1E911-UL2(DIV)E911 Sync

    Support of 2 independent BTS sources

    Termination loads for 2 x 46 dBm

    Un-duplexing of in-coming signal

    Measurement of RF-power from BTS and

    to BTS

    Signal combining

    Support of duplexed and non-duplexed

    signal

    Support of UL diversity

    Support of E911 call detection

    Test-tone generator for easy leveling and

    trouble-shooting

  • 5/24/2018 CommScope ION-M DAS Training

    49/108

    49

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    Intelligent Point of Interface (i-POI)

    External Alarms

    2 software defined inputs

    2 software defined output

    1 Summary-alarm

    Subrack address display

    with subrack alarm status

    Up to 8 independent POI modules

    LMT Interface

    DC main input & interface to system controller

    via backplane connectors

  • 5/24/2018 CommScope ION-M DAS Training

    50/108

    50

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    Intelligent Point of Interface (i-POI)

    46 dBm input power per BTS port (2 ports)

    Supports duplexed, non-duplexed & uplink

    diversity BTS inputs

    -153 dBc PIM @ 2 x 20 Watts

    Up to 8 POI modules (sectors) per subrack

    Automatic level control over a 60 dBrange in 0.5 dB increments

    Integrated tone generator for

    end-to-end signal leveling

    Real time power measurement & display

    End-to-end front panel fault indication(SW dependant)

    Can be used with third party DAS systems

    (internal web server) and fully integrated to

    the CommScope DAS solution

    Active Version

  • 5/24/2018 CommScope ION-M DAS Training

    51/108

    51

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    Rack Alarm Board (RAB)

    Collects and provides alarm outputs for Power Supply Units

    (PSU) Collects and provides alarm outputs for door and cabinet fan

    Alarm outputs would be connected to Rack Master Controller

    (RMC)

    RAB would be mounted in PSU subrack

    DOOR

    RAB

    PSU/FAN

    PWRPSU1

    PSU2

    PSU3

    PSU4

    PSU5

    PSU6

    PSU7

    PSU8

  • 5/24/2018 CommScope ION-M DAS Training

    52/108

    52

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Remote- M Cabinet

    ION-M Remote is available in various band configuration.

    Reference specific remote datasheet for power consumption.

  • 5/24/2018 CommScope ION-M DAS Training

    53/108

    53

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Remote- M Cabinet

  • 5/24/2018 CommScope ION-M DAS Training

    54/108

    54

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Remote- M Cabinet Connections

  • 5/24/2018 CommScope ION-M DAS Training

    55/108

    55

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Remote - Grounding

  • 5/24/2018 CommScope ION-M DAS Training

    56/108

    56

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Remote - Electrical Connections

  • 5/24/2018 CommScope ION-M DAS Training

    57/108

    57

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Remote - Electrical Connections

  • 5/24/2018 CommScope ION-M DAS Training

    58/108

    58

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Remote - Antenna Connections

  • 5/24/2018 CommScope ION-M DAS Training

    59/108

    59

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M RemoteOptical Fiber Connection

  • 5/24/2018 CommScope ION-M DAS Training

    60/108

    60

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M RemoteOptical Fiber Connection

    ION M S t Fib O ti S ifi ti

  • 5/24/2018 CommScope ION-M DAS Training

    61/108

    61

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M System Fiber Optics Specifications

    (2ndwindow)

    1310 nm 1550 nm

    (3rdwindow)

    Only One Optical Fiber Required

    Integral WDM Combines Uplink and Downlink Signals on a Common Fiber

    Downlink at 1310 nm Uplink at 1550 nm

    10 dB Optical Link Budget

    Optical Fiber Loss ~0.4 dB/km (1310 nm)

    10 dB optical budget for all RF parameters implies

    25 km(15 miles) fiber length

    Low Profile E2000-APC Connector

    Integral Dust Cover

    Easy Insertion and Snap Connection

    ION M R t M h i l I t ll ti

  • 5/24/2018 CommScope ION-M DAS Training

    62/108

    62

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Remote Mechanical Installation

    ION M R t M h i l I t ll ti

  • 5/24/2018 CommScope ION-M DAS Training

    63/108

    63

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Remote Mechanical Installation

    ION M R t M h i l I t ll ti

  • 5/24/2018 CommScope ION-M DAS Training

    64/108

    64

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Remote Mechanical Installation

    ION M Remote Mechanical Installation Wall Mounting

  • 5/24/2018 CommScope ION-M DAS Training

    65/108

    65

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Remote Mechanical Installation- Wall Mounting

    ION M Remote Mechanical Installation Pole Mounting

  • 5/24/2018 CommScope ION-M DAS Training

    66/108

    66

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Remote Mechanical Installation - Pole Mounting

    ION M Remote Mechanical Installation Pole Mounting

  • 5/24/2018 CommScope ION-M DAS Training

    67/108

    67

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Remote Mechanical Installation - Pole Mounting

    ION M Remote Status LED

  • 5/24/2018 CommScope ION-M DAS Training

    68/108

    68

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Remote Status LED

  • 5/24/2018 CommScope ION-M DAS Training

    69/108

    69

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Remote- ML Cabinet

    Reference specific remote datasheet for power consumption.

    ION M Remote W Cabinet

  • 5/24/2018 CommScope ION-M DAS Training

    70/108

    70

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Remote- W Cabinet

    ION-M Remote is available in various band configuration.

    Reference specific remote datasheet for power consumption.

  • 5/24/2018 CommScope ION-M DAS Training

    71/108

    71

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Single Band Remote Block Diagram

    OpticalInput

    Antenna

    O

    E

    PA

    LNA

    WDM

    O

    E

    Duplexer

    Micro-

    Controller

    Power

    Supply

    Heat

    Exchanger

    Dual Band Remote Block Diagram

  • 5/24/2018 CommScope ION-M DAS Training

    72/108

    72

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    Dual Band Remote Block Diagram

    O

    E

    PA

    LNA

    WDM

    O

    E

    Optical

    Input

    Duplexer

    Antenna

    PA

    LNA

    Micro-

    Controller

    Power

    Supply

    Heat

    Exchanger

  • 5/24/2018 CommScope ION-M DAS Training

    73/108

    73

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M17HP/19P Remote Specifications

    ION M DAS System Diagram

  • 5/24/2018 CommScope ION-M DAS Training

    74/108

    74

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M DAS System Diagram

    SubrackUL POI

    o

    e

    o

    e

    o

    e

    o

    e

    Subrack

    DL POI

    External

    UL POI

    e

    o

    Remote Unit

    Antenna

    A

    External

    DL POI

    RX

    BTS

    TX

    e

    o

    Remote Unit

    Antenna

    Master Subrack

    B

    C

    DION-M system gain specified

    from point A to point B

    ION M DAS System Diagram

  • 5/24/2018 CommScope ION-M DAS Training

    75/108

    75

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M DAS System Diagram

    TMO LIT HUB Plumbing

  • 5/24/2018 CommScope ION-M DAS Training

    76/108

    76

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    TMO LIT HUB Plumbing

    Basic Link Budget LIT

  • 5/24/2018 CommScope ION-M DAS Training

    77/108

    77

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    Basic Link Budget LIT

    ION-M DAS System Diagram

  • 5/24/2018 CommScope ION-M DAS Training

    78/108

    78

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M DAS System Diagram

    ION M 700 LTE MIMO/850/1900 design

  • 5/24/2018 CommScope ION-M DAS Training

    79/108

    79

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M 700 LTE MIMO/850/1900 design

    ION-M Remote Active Cooling

  • 5/24/2018 CommScope ION-M DAS Training

    80/108

    80

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION M Remote Active Cooling

    Small Form Factor

    Fans Are Easily Replaced

    Fan Speed Varies

    Fan Speed Increases as Heat sink

    Temperature Rises Fan Speed Decreases, or Stops,

    when Heat sink Temperature is Low

    ION-M Remote Passive Cooling

  • 5/24/2018 CommScope ION-M DAS Training

    81/108

    81

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Remote Passive Cooling

    Insensitive to Dust

    No Acoustic Noise Emission

    Useful for Tunnel Applications

    ION-M Remote Accessories

  • 5/24/2018 CommScope ION-M DAS Training

    82/108

    82

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION M Remote Accessories

    Fan Protection Cover

    Additional Environment

    Protection

    Mounting Brackets

    Wall Mount Option Pole Mount Option

    ION M Remote Overcoat Housing

  • 5/24/2018 CommScope ION-M DAS Training

    83/108

    83

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Remote Overcoat Housing

    Offers Protection

    Environment

    Vandalism

    Reduces Acoustical Noise

    May be Painted for SpecificRequirements

    ION-M Remote Master Controller Software Login

  • 5/24/2018 CommScope ION-M DAS Training

    84/108

    84

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    g

    At first login, enter the Username (owner), enter the default

    password (Apwd4own)> (case-sensitive, no blanks allowed). Changing the password is described inchapter 3.4.5 Owner Settings.

    Microsoft Windows Login username: mikom or andrew

    password: mikom or andrew

    ION-M Software

  • 5/24/2018 CommScope ION-M DAS Training

    85/108

    85

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Software

  • 5/24/2018 CommScope ION-M DAS Training

    86/108

    86

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    Home: leads back to the home page; Logou t: to log out of the system.

    The Tree Viewdisplays the current system topology determined during auto-setup in tree

    format.

    Current Alarm Statusshows the number of current alarms in order of their severities.

    Alarm severities are also indicated by a color code.

    The Home frame shows the current software version as well as supplementary

    information on the software of the Master Controller. When a unit is selected from theTree Viewthe menus available for the selected unit.

    The main frame provides a system overview in graphic form.

    ION M Software

    The three main menusSuperv is ion, Conf igurat ion, and Maintenanceare the

    same for all unit types; only the available submenus vary depending on the type of unit.

    ION-M Tree View

  • 5/24/2018 CommScope ION-M DAS Training

    87/108

    87

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    MC=Master Controller 1 per system (master

    unit including RMC600 & MMC+)

    SRMU=Subrack master unit (MU OTRX)up

    to ~50 per controller

    RU=Remote unit 1 per SRMU

    SAB=System alarmboard 1 per system

    (option)

    RAB=Rack alarmboard 1 per rack (option)

    SRMU (OTRx) Menu

  • 5/24/2018 CommScope ION-M DAS Training

    88/108

    88

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ( )

    ION-M Remote (RU) Menu

  • 5/24/2018 CommScope ION-M DAS Training

    89/108

    89

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    HW/RF Parameters

  • 5/24/2018 CommScope ION-M DAS Training

    90/108

    90

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    RAB Menu (Rack Alarm Board)

  • 5/24/2018 CommScope ION-M DAS Training

    91/108

    91

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ( )

    The RAB collects alarms from up to

    8 PSUs, two fan sets, one door

    alarm and mains-failure (if an UPS

    is connected).

    SAB Menu (System Alarmboard )

  • 5/24/2018 CommScope ION-M DAS Training

    92/108

    92

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    Active Alarms and History

  • 5/24/2018 CommScope ION-M DAS Training

    93/108

    93

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    This screen shows all thealarms that are active in the

    whole system.

    These alarm messages will

    also be displayed in the

    Alarm History.

    Handling of Alarms

  • 5/24/2018 CommScope ION-M DAS Training

    94/108

    94

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    MMC+ Master Controller software will show all existing alarms in the system

    All alarms can be resolved with a process of elimination and respective units can

    be replaced/repaired as needed

    Click on to get summary

    Remote Unit Alarm Indication

  • 5/24/2018 CommScope ION-M DAS Training

    95/108

    95

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    Following alarms are indicated from LED at

    connector flange:

    LED off: No power Bad power supply

    No VAC input

    LED green: No alarm

    LED yellow: Alarms not directly related to RU

    External alarms

    Optical RX alarm

    all ALC alarms

    LED red: Alarms directly related to RU

    Power alarms 12 & 28 V

    Temperature

    Fan

    I2C Bus

    Optical TX alarm

    Amplifier power down

    RU Alarms

  • 5/24/2018 CommScope ION-M DAS Training

    96/108

    96

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    If showing alarm at RU site; check with HUB or NOC to see what the alarm is

    reported in Master Controller software.

    ALC Alarm: Check RF input level, Check RU ALC settings. PA Alarm: Check RF input level, Check amplifier software configuration,

    Reset amplifier via software, hard reset unit (disconnect power).

    Temperature Alarm: Check if fans are working, ensure proper airflow (air-

    deflectors), power down unit to alleviate further over-heating.

    Unit Unavailable: Check fiber, try spare fiber.

    SRMU Alarms

  • 5/24/2018 CommScope ION-M DAS Training

    97/108

    97

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    Flashing E No connection with RU: Check fiber, RU power, and controller software foralarm message.

    Flashing I I2C Bus Error: Re-seat card in subrack, replace OTRx.

    Alarms and Troubleshooting

  • 5/24/2018 CommScope ION-M DAS Training

    98/108

    98

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    SRMU Alarms

    Fiber optic RX/TX alarm

    Bus I2C failure

    System temperature

    Fiber optic DL/UL current

    Unit unavailable

    A detailed list of all alarms is provided in the User Manual for Optical Master unit.

    Cannot Connect to the MMC+

  • 5/24/2018 CommScope ION-M DAS Training

    99/108

    99

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    What is the status light telling you?

    Do you have a network connection (LAN) on your computer?

    What is the IP address that has been assigned to your computer?

    Cannot connect to the MMC+

  • 5/24/2018 CommScope ION-M DAS Training

    100/108

    100

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    If you have a network connection established with your computer try NetMeeting.

    NetMeeting allows you to controll the MMC+ desktop. Start Run conf

    Username = andrew Password = andrew

    NetMeeting not included with Windows 7 (Windows XP Virtual Mode)

    Cannot connect to the MMC+

  • 5/24/2018 CommScope ION-M DAS Training

    101/108

    101

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    MMC+ is a Windows2000 PC.

    Controller services run on the PC to perform many software

    functions. Sometimes these services will not get started correctly and

    not allow web access to the ION-M software.

    ION-M Master Unit Installation

  • 5/24/2018 CommScope ION-M DAS Training

    102/108

    102

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    The Master Unit is Co-

    Located with Base Stations

    Easy Accessible

    Easy Maintenance

    Decrease Costs

    ION-M Remote Installation

  • 5/24/2018 CommScope ION-M DAS Training

    103/108

    103

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    Invisible Mounting

    RF Portion Below

    Ground

    Cooling Portion

    Integrated in Lower

    Portion of Waste Basket

    ION-M Remote Installation

  • 5/24/2018 CommScope ION-M DAS Training

    104/108

    104

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    ION-M Remote Installation

  • 5/24/2018 CommScope ION-M DAS Training

    105/108

    105

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    Invisible Mounting

    Installed inside the

    light pole

    Coolingaccomplished inside

    pole

    ION-M Remote Installation

  • 5/24/2018 CommScope ION-M DAS Training

    106/108

    106

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    Minimal VisualImpact

    Residential

    Setting

    Standard wooden

    utility pole

    CommScope TECHNICAL SUPPORT

  • 5/24/2018 CommScope ION-M DAS Training

    107/108

    107

    PRIVATE AND CONFIDENTIAL

    2012 CommScope, Inc

    WWW.COMMSCOPE.COM

    http://www.commscope.com/andrew/eng/product/cov_cap/index.html

    CommScope Wireless Solutions - Joliet, IL 60433

    Customer Support Center

    800-255-1479

    CommScope Distributed Coverage and Capacity Solutions

    Technical Support - Garner, NC 27529888-297-6433

    http://www.commscope.com/http://www.commscope.com/
  • 5/24/2018 CommScope ION-M DAS Training

    108/108

    Thank you!