+ All Categories
Home > Documents > Communications Power Management Solutions

Communications Power Management Solutions

Date post: 18-Oct-2021
Category:
Upload: others
View: 1 times
Download: 0 times
Share this document with a friend
20
Communications Power Management Solutions
Transcript
Page 1: Communications Power Management Solutions

Communications Power Management Solutions

Page 2: Communications Power Management Solutions

1

Make E-T-A yourDesign Partner

Power management solutions begin with an

understanding of your requirements. From

concept to production, E-T-A is equipped

with the expertise and tools necessary to de-

velop and produce a solution to meet the ex-

act specifications of your application regard-

less of the complexity.

Design

As your design partner, E-T-A adds circuit

protection expertise, electromechanical de-

sign and project management capabilities

to your team. This allows your design en-

gineers to maintain their focus on customer

and revenue critical applications while E-T-A

designs and supplies your power manage-

ment solutions.

Single Source Provider

E-T-A will streamline component sourcing

and vendor selection to reduce material and

inventory management requirements. E-T-

A’s efficient management and strong rela-

tionships with component vendors ensures

your power management systems will be

built with the best and most cost-effective

materials - giving your product offering the

competitive edge.

Manufacturing

Once the design is ap-

proved, E-T-A utilizes

state of the art equip-

ment, documented pro-

cesses and skilled labor

to build prototypes and

manufacture high vol-

ume orders. E-T-A’s

fully staffed manufac-

turing operation eliminates the need for you

to maintain and manage in-house manu-

facturing labor and eliminates the need for

manufacturing space for power management

systems.

Quality & Testing

Quality is E-T-A’s top priority. All power man-

agement solutions are manufactured and

100% tested in E-T-A’s ISO certified facility

prior to shipping. You

can be confident know-

ing the E-T-A power

management system

being integrated into

your equipment is built

and tested to the high-

est standards.

Page 3: Communications Power Management Solutions

Part number Description Pages

PDB-8340-0606-(XX) 1RU, Pluggable CBE 3 - 4

PDB-8345-0607-(XX) 1RU, Pluggable CBE 5 - 6

X1180R-S00-0500-1-240X00-(XX)-048X1180R-S00-0500-2-120X120-(XX)-048

1RU, Standard 19” 7 - 8

X8345R-S00-0584-2-03X30-(XX)-NA-058208X8345R-S00-0584-2-03X30-(XX)-E-058208

2RU, Pluggable CBE 9 - 10

X8345R-S00-0584-4-33X33-(XX)-NA-058208X8345R-S00-0584-4-33X33-(XX)-E-058208

2RU, Pluggable CBE 11 - 12

X452R-S00-0572-4-33X33-(XX)2RU, Pluggable CBE, Quick Connect

13 -14

X8340R-S00-0618-(XX) 2RU, Pluggable CBE 15 - 16

Breakers & System Accessories 17 - 18

StandardSystems

2

Page 4: Communications Power Management Solutions

PDB-8340-0606-(XX) 1RU, Pluggable CBE

Description

View

• Isolated A and B power regions for redundancy

• (2) PWR and (2) RTN inputs each side

• (6) PWR and (6) RTN outputs each side

• Inputs accept common 2-hole compression lugs up to 2 AWG

cable or 2-hole narrow tongue compression lugs up to 2/0 cable.

• Output accepts standard ring tongue terminals up to 10 AWG

cable, narrow tongue up to 8 AWG

• 1RU, Standard 19” rack mount chassis width, 8.25” chassis

depth

• Mounting flange options available for EIA 19”, 23” and ETSI

standard mounting

• Pluggable Circuit Breaker for field install or upgrade.

• E-T-A 8340 series, Hydraulic-Magnetic, UL1077 circuit

breakers (1A to 50A configurations avail. per channel)

• Voltage status indicator on each input

• LED on : Voltage live at system

• LED Green : Polarity Correct

• LED Red : Polarity Incorrect

• Options:

• Jumper Bar for reduced input configurations

• Alarm indicators and output

3

Page 5: Communications Power Management Solutions

Schematic diagram

Technical Data

Standard Part Numbers

Part Number Supply Feeds Breakers per feed Rack mount size Operating Voltage Current Carrying Capacity

PDB-8340-0606-19

4 3

19”- 72 VDC

to72 VDC

300 APDB-8340-0606-23 23”

PDB-8340-0606-ETSI ETSI

Dimensions 17.50” x 1.75” x 8.70”

Rack Mounting 19”, ETSI, 23” & Custom

Operating Voltage -72 VDC to 72 VDC

Operating Temperature - 5° C to 55° C

Current Carrying Capacity 300 A

Breaker Capacity 12 channels, 50 A max per channel

Circuit Protection/Control Hydraulic Magnetic - Single Pole

Circuit Breaker 8340-G110-R1H1-A7H0-xxA

Input Terminals 2-hole lug, 1/4”-20 studs, 5/8” offset

Output Terminals #8-32 screw terminal, Phillips

Chassis Ground 2-hole lug, 1/4”-20 studs, 5/8” offset

Hardware 1/4” kep nuts, #8 screws (included)

RoHs Status Compliant

Approvals • UL, CSA, CB Scheme Pending

• Designed to meet NEBs Level 3

4

Page 6: Communications Power Management Solutions

PDB-8345-0607-(XX)1RU, Pluggable CBE

Description

View

• Isolated A and B power regions for redundancy

• (2) PWR and (2) RTN inputs each side

• (2) PWR and (2) RTN outputs each side

• Inputs and Outputs accept common 2-hole compression lugs up

to 2 AWG cable or 2-hole narrow tongue compression lugs up to

2/0 cable.

• 1RU, Standard 19” rack mount chassis width, 8.25” chassis

depth

• Mounting flange options available for EIA 19”, 23” and ETSI

standard mounting

• Pluggable Circuit Breaker for field install or upgrade.

• E-T-A 8345 series, Hydraulic-Magnetic, UL489 circuit

breakers (1A to 125A configurations avail.)

• Voltage status indicator for each input

• LED on : Voltage live at system

• LED Green : Polarity Correct

• LED Red : Polarity Incorrect

• Options:

• Jumper bar for reduced input configuration

• Alarm indicators and output

5

Page 7: Communications Power Management Solutions

Schematic diagram

Technical Data

Dimensions 17.50” x 1.75” x 8.23”

Rack Mounting 19”, ETSI, 23” & Custom

Operating Voltage -72VDC to 72VDC

Operating Temperature -5°C to 55°C

Current Carrying Capacity 250 A

Breaker Capacity 4 channels, 125 A max. per channel

Circuit Protection/Control Hydraulic Magnetic - Single Pole

Circuit Breaker

Switch

8345-F01Z-R0M1-DB1B2B-(1-125A)

8345-F01Z-R0M1-DB1B1B-125A

Input Terminals 2-hole lug, 1/4”-20 studs, 5/8” offset

Output Terminals 2-hole lug, 1/4”-20 studs, 5/8” offset

Chassis Ground 2-hole lug, 1/4”-20 studs, 5/8” offset

Hardware 1/4” Kep Nuts (Included)

RoHs Status Compliant

Approvals • UL, CSA, CB Scheme Pending

• Designed to meet NEBs Level 3

Standard Part Numbers

Part Number Supply Feeds Breakers per feed Rack mount size Operating Voltage Current Carrying Capacity

PDB-8345-0607-19

4 1

19”-72VDC

to72VDC

250 APDB-8345-0607-23 23”

PDB-8345-0607-ETSI ESTI

6

Page 8: Communications Power Management Solutions

X1180R-S00-05421RU, Standard 19”

Description

View

• Isolated A and B power regions for redundancy

• (1) PWR and (1) RTN inputs each side

• (12) PWR and (12) RTN outputs each side

• Inputs accept common 2-hole compression lugs up to 2/0 cable.

• Output accepts bare wire – 20 to 12 AWG cable

• 1RU, Standard 19” rack mount chassis width, 9.14” chassis

depth

• Mounting flange options available for EIA 19”, 23” and ETSI

standard mounting

• Pluggable Circuit Breaker for field install or upgrade.

• E-T-A 1180 series, Thermal CBE, UL1077 circuit breakers

(0.1A to 10A configurations avail.)

7

Page 9: Communications Power Management Solutions

Schematic diagram

Technical Data

Module 1

IN 1

Module 2

OUT 1CB 1

CB 2

CB 3

CB12

CB 1

CB 2

CB 3

CB12

OUT 2

OUT 3

OUT 12

OUT 1

OUT 2

OUT 3

OUT 12

Module 1 Module 2

IN 1

OUT 1CB 1

CB 2

CB12

CB 1

CB 2

CB 3

CB12

OUT 2

OUT 12

OUT 1

OUT 2

OUT 3

OUT 12

CB 3 OUT 3

IN 1

Standard Part Numbers

Part Number Supply Feeds Breakers per feed Rack mount size Operating Voltage Current Carrying Capacity

X1180R-S00-0542-1-240X00-19-0481 24

19”

- 72 VDCto

72 VDC

120AX1180R-S00-0542-1-240X00-23-048 23”

X1180R-S00-0542-2-120X120-19-0482 12 + 12

19”240A

X1180R-S00-0542-2-120X120-23-048 23”

X1180R... 00X240 X1180R... 120X120

Dimensions 17.50” x 1.75” x 9.14”

Rack Mounting 19”, 23”, ETSI & Custom

Operating Voltage - 72 VDC to 72 VDC

Operating Temperature - 5° C to - 55° C

Current Carrying Capacity 240A

Breaker Capacity 24 channels , 10 A max per channel

Circuit Protection/Control Thermal - Single Pole

Circuit Breaker 1180-01-(0.1 - 10A)

Input Terminals 2-hole lug, M6 studs, 5/8” offset

Output Terminals Screw terminal - bare wire termination

Chassis Ground 2-hole lug, M6 studs, 5/8” offset

RoHs Status Compliant

Approvals • UL

• CSA

• CB

• Designed to meet NEBs Level 3

8

Page 10: Communications Power Management Solutions

X8345R-S00-0584-2-03X30-(XX)-(X)-058208;2RU, Pluggable CBE

Description

View

• Isolated A and B power regions for redundancy

• (1) PWR and (1) RTN inputs each side

• (3) PWR and (3) RTN outputs each side

• Inputs accept common 2-hole compression lugs up to 2/0 cable

• Outputs accept common 2-hole compression lugs up to 2 AWG

cable

• Rear and Side cable access

• 2RU, Standard 19” rack mount chassis width, 8.25” chassis

depth

• Mounting flange options available for EIA 19”, 23” and ETSI

standard mounting

• Pluggable circuit breaker for field instalation or upgrade

• E-T-A 8345 series, Hydraulic-Magnetic,UL489 circuit

breakers (1A to 125A configurations avail.)

• Option:

• Slide rail kit available for ETSI and 23” version

9

Page 11: Communications Power Management Solutions

Technical Data

Standard Part Numbers

Dimensions 17.50” x 3.50” x 11.10”

Rack Mounting 19”, ETSI, 23” & Custom

Operating Voltage -72VDC to 72VDC

Operating Temperature -5°C to 52°C

Current Carrying Capacity 240A @ 52°C / 250A @ 42°C

Breaker Capacity 6 channels - 80A per channel @ 52°C90A per channel @ 42°C

Circuit Protection/Control Hydraulic Magnetic - Single Pole

Circuit Breaker

Switch

8345-F01Z-R0M1-DB1B2B-(1-90A)

8345-F01Z-R0M1-DB1B1B-125A

Input Terminals 2-hole lug, M6 studs, 5/8” offset

Output Terminals 2-hole lug, M6 studs, 5/8” offset

Chassis Ground 2-hole lug, M6 studs, 5/8” offset

Hardware Included M6 Kep Nuts (Included)

RoHs Status Compliant

Approvals • UL Listed

• CSA

• CB

• Designed to meet NEBs Level 3

Part Number Supply Feeds Breakers per feed Rack mount size Operating VoltageCurrent Carrying

Capacity

X8345R-S00-0584-2-03x30-19-NA-058208

2 3

19”

-72VDCto

72VDC250A

X8345R-S00-0584-2-03x30-ETSI-NA-058208 ETSI

X8345R-S00-0584-2-03x30-23-NA-058208 23”

X8345R-S00-0584-2-03x30-19-E-058208 19”

X8345R-S00-0584-2-03x30-ETSI-E-058208 ETSI

X8345R-S00-0584-2-03x30-23-E-058208 23”

10

Schematic diagram

X8345R-S00-0584-2-03x30-xx-NA-058208

X8345R-S00-0584-2-03x30-xx-E-058208

Page 12: Communications Power Management Solutions

X8345R-S00-0584-4-33X33-(XX)-(X)-058208;2RU, Pluggable CBE

Description

View

• Isolated A and B power regions for redundancy

• (2) PWR and (2) RTN inputs each side

• (6) PWR and (6) RTN outputs each side

• Inputs accept common 2-hole compression lugs up to 2/0 cable

• Outputs accept common 2-hole compression lugs up to 2 AWG

cable

• Rear and Side cable access

• 1RU, Standard 19” rack mount chassis width, 8.25” chassis depth

• Mounting flange options available for EIA 19”, 23” and ETSI standard

mounting

• Pluggable circuit breaker for field install or upgrade

• E-T-A 8345 series, Hydraulic-Magnetic,UL489 circuit breakers

(1A to 125A configurations avail.)

• Options:

• Slide rail kit available for ETSI and 23” version

• Jumper bar for reduced input configruation

11

Page 13: Communications Power Management Solutions

Schematic diagram

Technical Data

Standard Part Numbers

Dimensions 17.50” x 3.50” x 11.10”

Rack Mounting 19”, ETSI, 23” & Custom

Operating Voltage -72VDC to 72VDC

Operating Temperature -5°C to 42°C

Current Carrying Capacity 500A

Breaker Capacity 12 channels, 90A max. per channel

Circuit Protection/Control Hydraulic Magnetic - Single Pole

Circuit Breaker

Switch

8345-F01Z-R0M1-DB1B2B-(1-90A)

8345-F01Z-R0M1-DB1B1B-90A

Input Terminals 2-hole lug, M6 studs, 5/8” offset

Output Terminals 2-hole lug, M6 studs, 5/8” offset

Chassis Ground 2-hole lug, M6 studs, 5/8” offset

Hardware M6 Kep Nuts (Included)

RoHs Status Compliant

Approvals • UL Listed

• CSA

• CB Scheme

• Designed to meet NEBs Level 3

Part Number Supply Feeds Breakers per feed Rack mount size Operating VoltageCurrent Carrying

Capacity

X8345R-S00-0584-4-33X33-19-NA-058208

4 3

19”

-72VDCto

72VDC500A

X8345R-S00-0584-4-33X33-ETSI-NA-058208 ESTI

X8345R-S00-0584-4-33X33-23-NA-058208 23”

X8345R-S00-0584-4-33X33-19-E-058208 19”

X8345R-S00-0584-4-33X33-ETSI-E-058208 ESTI

X8345R-S00-0584-4-33X33-23-E-058208 23”

X8345R-S00-0584-4-33X33-xx-NA-058208

X8345R-S00-0584-4-33X33-xx-E-058208

12

INPUTB1

A1

A2

INPUTA1

OUTPUTA1

-BATT

+RTN

-BATT

+RTN

OUTPUTA2

A4

A5

INPUTA2

A3OUTPUT

A3

A6

OUTPUTA4

OUTPUTA5

OUTPUTA6

B1

B2

OUTPUTB1

OUTPUTB2

B4

B5

INPUTB2

B3OUTPUT

B3

B6

OUTPUTB4

OUTPUTB5

OUTPUTB6

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

INPUTB1

A1

A2

INPUTA1

OUTPUTA1

-BATT

+RTN

-BATT

+RTN

OUTPUTA2

A4

A5

INPUTA2

A3OUTPUT

A3

A6

OUTPUTA4

OUTPUTA5

OUTPUTA6

B1

B2

OUTPUTB1

OUTPUTB2

B4

B5

INPUTB2

B3OUTPUT

B3

B6

OUTPUTB4

OUTPUTB5

OUTPUTB6

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

Page 14: Communications Power Management Solutions

X452-S00-0572-4-33X33-(XX)2RU, Pluggable CBE, Quick Connect

Description

View

• Isolated A and B power regions for redundancy

• (2) PWR and (2) RTN inputs each side

• (6) PWR and (6) RTN outputs each side

• Inputs accept common 2-hole compression lugs up to 1/0 or 2-hole

flex lug up to 1 AWG

• Outputs accept Anderson PP75 quick connects

• 2 RU standard 19” rack mount chassis width, 9.75” chassis depth

• Mounting flange options available for EIA 19”, 23” and ETSI standard

mounting

• Pluggable circuit breaker for field install or upgrade

• E-T-A 8340 series, Hydraulic-Magnetic, UL 1077 circuit breakers

(1 - 50A configurations available per channel)

• E-T-A 452 series, Thermal-Magnetic, UL 1077 circuit breakers

(1 - 125A configurations availbale per channel)

13

Page 15: Communications Power Management Solutions

Schematic diagram

Technical Data

Dimensions 17.50” x 3.50” x 9.25”

Rack Mounting 19”, ETSI, 23” & Custom

Operating Voltage -72 VDC to 72 VDC

Operating Temperature - 5°C to 55°C

Current Carrying Capacity 450A

Breaker Capacity 12 channels, 75A max per channel

Circuit Protection/Control Thermal Magnetic - Single Pole

Hydraulic Magnetic - Single Pole

Circuit Breaker

Circuit Breaker

8340-G110-R1H1-A7H0-xxA

452-R1LN2-xxA

Standard Part Numbers

Part Number Supply Feeds Breakers per feed Rack mount size Operating Voltage Current Carrying Capacity

X452R-S00-0572-19

4 3

19”- 72 VDC

to72 VDC

450AX452R-S00-0572-ETSI ETSI”

X452R-S00-0572-23 23”

Input Terminals 2-hole lug, 1/4”-20 studs, 5/8” offset

Output Terminals Anderson PP75

Chassis Ground 2-hole lug, 1/4”-20 studs, 5/8” offset

Hardware 1/4” kep nuts (included)

RoHs Status Compliant

Approvals • UL, CSA, CB Scheme Pending

• Designed to meet NEBs Level 3

14

Page 16: Communications Power Management Solutions

Description

View

• Isolated A and B power regions for redundancy

• (2) PWR and (2) RTN inputs each side

• (6) PWR and (6) RTN outputs each side

• Inputs accept common 2-hole compression lugs up to 2 AWG

cable or 2-hole narrow tongue compression lugs up to 2/0 cable.

• Output accepts standard ring tongue terminal s up to 10 AWG

cable, narrow tongue up to 8 AWG

• 1RU, Standard 19” rack mount chassis width, 8.25” chassis

depth

• Mounting flange options available for EIA 19”, 23” and ETSI

standard mounting

• Pluggable Circuit Breaker for field install or upgrade.

• E-T-A 8340 series, Hydraulic-Magnetic, UL1077 circuit

breakers (1A to 50A configurations avail. per channel)

• Voltage status indicator on each input

• LED on : Voltage live at system

• LED Green : Polarity Correct

• LED Red : Polarity Incorrect

• Options:

• Jumper bar for reduced Input configurations

• Alarm indicators and output

X8340R-S00-0618-(XX)2RU, Pluggable CBE

15

Page 17: Communications Power Management Solutions

Schematic diagram

Technical Data

Standard Part Numbers

Part Number Supply Feeds Breakers per feed Rack mount size Operating Voltage Current Carrying Capacity

X8340R-S00-0618-19

4 3

19”- 72 VDC

to72 VDC

300AX8340R-S00-0618-ETSI ETSI

X8340R-S00-0618-23 23”

Dimensions 17.50” x 3.50” x 9.50”

Rack Mounting 19”, ETSI, 23” & Custom

Operating Voltage -72 VDC to 72 VDC

Operating Temperature - 5° C to 55° C

Current Carrying Capacity 300 A

Breaker Capacity 12 channels, 50 A max per channel

Circuit Protection/Control Hydraulic Magnetic - Single Pole

Circuit Breaker 8340-G110-R1H1-A7H0-xxA

Input Terminals 2-hole lug, 1/4”-20 studs, 5/8” offset

Output Terminals #8-32 screw terminals, Phillips

Chassis Ground 2-hole lug, 1/4”-20 studs, 5/8” offset

Hardware 1/4” kep nuts, #8 screws (included)

RoHs Status Compliant

Approvals • UL Listed

• CSA

• CB Scheme

• Designed to meet NEBs Level 3

PWRA1-1

A1-2

OUTPUTA1-1

OUTPUTA1-2

A1-3OUTPUT

A1-3

-BATT -BATT+RTN

+RTN-BATT

+RTN-BATT

INPUT A1

PWRA2-4

A2-5

OUTPUTA2-4

OUTPUTA2-5

A2-6OUTPUT

A2-6

-BATT -BATT+RTN

+RTN-BATT

+RTN-BATT

INPUT A2

+RTN

A-SIDE

RTN+RTN

RTN

PWRB1-1

B1-2

OUTPUTB1-1

OUTPUTB1-2

B1-3OUTPUT

B1-3

-BATT -BATT+RTN

+RTN-BATT

+RTN-BATT

INPUT B1

PWRB2-4

B2-5

OUTPUTB2-4

OUTPUTB2-5

B2-6OUTPUT

B2-6

-BATT -BATT+RTN

+RTN-BATT

+RTN-BATT

INPUT B2

+RTN

B-SIDE

RTN+RTN

RTN

VOLTAGE MONITOR

INPUT A1 STATUSINPUT A2 STATUS

VOLTAGE MONITOR

INPUT B1 STATUSINPUT B2 STATUS

16

Page 18: Communications Power Management Solutions

Circuit BreakerTechnical Information

DescriptionMiniturized single pole thermal cir-cuit breaker with switching function optional (push-push actuation)

Thermal-magnetic, threadneck panel mounting, push/pull opera-tion, with auxiliary contact option

Voltage Rating250 VAC; 65 VDC *(*UL, UL Canada: 250 VAC; 72 VDC)

28 VDC

Current Ratings 0.1... 10A 50... 100A

Typical Life/ Contact Rating6,000 operations at 1 x IN, resistive3,000 operations at 1 x IN, inductive500 operations at 2 x IN, inductive

2500 operations at 1 x IN

Interrupting Capacity Icn 0.1... 5A 6 x IN6... 10A 8 x IN

28 VDC; 6000A115 VAC (400 Hz); 1500A

Approvals UL, UL Candad, VDEUL, VG 95345 part 17, QPL Canada, QPL Sweeden

Dimensions

Internal Connection Diagrams

1180 452

line 1

2

I >

1

2

1.9

1.5

48.6

ON

48.8

52.3

OFF

24.4.961

.780

.075

.059

1.91

1.92

17

Page 19: Communications Power Management Solutions

Thermal, single-pole, threadneck panel mounting, push/pull opera-tion, with auxiliary contact option

Push/pull circuit breaker, thread-neck panel mounting, with auxiliary option. UL 489 A approval

Toggle circuit breaker, flange mounting, with auxiliary contact option and UL 489 approval

115 VAC (400 Hz), 28 VDC** UL: 72 VDC

3 AC 415 V;240 VAC * (50/60 Hz); 80 VDC* UL, CSA: 250 VAC

80 VDC; 240 VAC;AC 120/240 V; AC 277/480 V;2 AC 415 V

0.1...50A0.02... 50 A single pole0.02... 30 A multipole(UL: 0.02... 50 A multipole)

0.05... 125 AHigher ratings available upon request

10,000 operations, mechanical5,000 operations at 1 x IN

10,000 operations with1 x IN, resistive 1 pole5,000 operations with 1 x IN, resis-tive 2 pole

10,000 operations with 1 x IN

0.1...2.5 A 15 x IN3...3.5A 250 A DC/100 A AC4...7A 500 A7.5...50 A 6,000 A DC/ 1,000 A AC35...50 A 3,000 A DC/ 1,000 A AC

AC: 1,200 ADC: 2,000 A

AC: 5,000 ADC: 10,000 A

UL, CSA, QPL Canada, VG 95345 T21

UL, CSA, VDE, CCC UL, VDE

482 8340 8345

2

line 1

line 1 11 23

12 24

2(k) load

I >

line 1 11(C)

2 (load)

I > 14(NO)12(NC)

12.2

O

FF ON M12x1

6

max

. 6.3

5

42.2

22

19.6

.866

.772

1.66max

.250

.480

.236

1.5

.059

6.5

57.5

.256

2.26

ON

12.5

M12x1

18.2

.492

OFF

1.5

.059

.717

1 11 23 2(i) 24 12 2( k)

19.5

34

22.5

61.34

.768 .886

.236

ENILDAOL

49.21.94

1.94

.756

49.2

19.2

18

Page 20: Communications Power Management Solutions

E-T-A Circuit Breakers 1551 Bishop Ct.Mt. Prospect, IL 60056Phone (847) 827-7600 Fax (847) [email protected]

communications_portfolio_5/611


Recommended