INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV- Rev. 06.30.14 PAGE 1TECH SUPPORT: 1.888.678.9427
The ComNet series video transmitters and receivers support the transmission of one, two, or four independent short-haul quality 10-bit digital video signals and one, two, or four contact closures in the direction of the video over multimode or single mode optical fibers. These modules are universally compatible with major CCTV camera manufacturers. The receivers are compatible with the FVT1(M,S)1/M* series single channel transmitters. Plug-and-play design ensures ease of installation and no electrical or optical adjustments are ever required.
Bi-color (Red/Green) LED indicators are provided for rapidly confirming operating status. Please see Figure 10 on Page 7 for LED explanations.
The FVT10C1(M,S)1/M units have a small footprint and are ideal for mounting where space is limited or can be mounted inside equipment housing. The remaining ComFit units may be either wall or rack-mounted. Please see Figures A and B on Page 8 for mounting instructions.
* FVT1(M,S)1/M not available in North America.
INSTALLATION AND OPERATION MANUAL
FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4SINGLE, DUAL OR QUAD-CHANNEL 10-BIT DIGITALLY ENCODED SHORT-HAUL VIDEO AND CONTACT CLOSURE
This manual serves the following ComNet Model Numbers:
FVT10C1M1/MFVT10C1S1/MFVT10C1M1FVT10C1S1FVR10C1M1FVR10C1S1FVR20C2M2FVR20C2S2FVR40C4M4FVR40C4S4
INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV- Rev. 06.30.14 PAGE 2
INSTALLATION AND OPERATION MANUAL FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4
TECH SUPPORT: 1.888.678.9427
BNC Video
Power Input & Contact Closure
Power Supply: 9 36VDC @ 2W OR 12 24 VAC @ 2W
FIGURE 2 FVT10C1/M TRANSMITTER
FIGURE 1 FVT10C1/M TRANSMITTER
REAR PANEL
FRONT PANEL
Multimode or Single ModeOptical Fiber
Mounting Bracket
(Included)
INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV- Rev. 06.30.14 PAGE 3
INSTALLATION AND OPERATION MANUAL FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4
TECH SUPPORT: 1.888.678.9427
FIGURE 3 FVT10C1 TRANSMITTER
FIGURE 2 FVT10C1 TRANSMITTER
REAR PANELFRONT PANEL
Multimode or Single Mode Optical Fiber
Video Signal In
Contact In
BlackBlack With White Stripe
Power Supply:Surface Mount: 8 15VDC @ 2WRack Mount: From Rack
NOTE: Remove Electrical Connector for Rack Mount Units
INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV- Rev. 06.30.14 PAGE 4
INSTALLATION AND OPERATION MANUAL FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4
TECH SUPPORT: 1.888.678.9427
FIGURE 5 FVR10C1 RECEIVER
FIGURE 4 FVR10C1 RECEIVER
REAR PANELFRONT PANEL
Multimode or Single ModeOptical Fiber
Video Signal Out
Contact Out
BlackBlack With White Stripe
Power Supply:Surface Mount: 8 15VDC @ 2WRack Mount: From Rack
NOTE: Remove Electrical Connector for Rack Mount Units
INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV- Rev. 06.30.14 PAGE 5
INSTALLATION AND OPERATION MANUAL FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4
TECH SUPPORT: 1.888.678.9427
Video Signal Out
CH
AN
NEL
1C
HA
NN
EL 2
Video Signal Out
Contact Out
Contact Out
FIGURE 7 FVR20C2 RECEIVER
FIGURE 6 FVR20C2 RECEIVER
REAR PANELFRONT PANEL
Multimode or Single Mode Optical Fiber
BlackBlack With White Stripe
Power Supply:Surface Mount: 8 15VDC @ 2WRack Mount: From Rack
NOTE: Remove Electrical Connector for Rack Mount Units
INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV- Rev. 06.30.14 PAGE 6
INSTALLATION AND OPERATION MANUAL FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4
TECH SUPPORT: 1.888.678.9427
CH1 Video Signal Out
CH2 Video Signal Out
CH3 Video Signal Out
CH4 Video Signal Out
Contact Out
Contact Out
FIGURE 9 FVR40C4 RECEIVER
FIGURE 8 FVR40C4 RECEIVER
REAR PANELFRONT PANEL
Multimode or Single Mode Optical Fiber
BlackBlack With White Stripe
Operating Voltage Range: 8 to 15VDC Power Consumption: 4W
NOTE: Remove Electrical Connector for Rack Mount Units
INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV- Rev. 06.30.14 PAGE 7
INSTALLATION AND OPERATION MANUAL FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4
TECH SUPPORT: 1.888.678.9427
FIGURE 10 LED INDICATORS
LINK (RECEIVERS ONLY) VIDEO CONTACT*
GREEN Communication link has been established over optical fiber
Video signal is present on the channel.
Contact input is closed.
RED Communication link has not been established.
Video signal is not present on the channel.
OFF Unit powered down. Unit powered down. Contact input is open.
* Contact Closure channels are not operational when used with the FVT1(M,S)1/M transmitters.
INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV- Rev. 06.30.14 PAGE 8
INSTALLATION AND OPERATION MANUAL FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4
TECH SUPPORT: 1.888.678.9427
2014 Communications Networks Corporation. All Rights Reserved. ComNet and the ComNet Logo are registered trademarks of Communication Networks, LLC.
3 CORPORATE DRIVE | DANBURY, CT 06810 | USA T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | [email protected]
8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LET: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | [email protected]
FIGURE BDimensions are for a standard ComNet one slot module
.156 [3.96 mm]
.313 [7.95 mm]
INSTALLATION CONSIDERATIONS
The FVT10C1(M,S)1/M is supplied as a Standalone/Surface Mount module. The remaining units covered in this manual are supplied as Standalone/Rack (ComFIt) modules. Units should be installed in dry locations protected from extremes of temperature and humidity.
C1-US, C1-EU, C1-AU OR C1-CH CARD CAGE RACKS
CAUTION: Although the units are hot-swappable and may be installed without turning power off to the rack, ComNet recommends that the power supply be turned off and that the rack power supply is disconnected from any power source. Note: Remove electrical connector before installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the racks connector panel. Seating may require thumb pressure on the top and bottom of the cards front panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack.
WARNING: Unit is to be used with a Listed Class 2 power supply.
IMPORTANT SAFEGUARDS:
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.
FIGURE ADimensions are for a ComNet FVT10C1/M module
4.5in (11.7cm)
2.2in (5.5cm)
1.1in (2.7cm)