+ All Categories
Home > Documents > Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers...

Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers...

Date post: 17-Jun-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
47
Compact Cabinet Coolers Catalog
Transcript
Page 1: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Compact CabinetCoolers

C a t a l o g

Page 2: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact Cabinet C

oolersNOREN ProductsInc.2

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

Table of ContentsClick on the link to view the content

IntroductionFeaturesDetermine Heat LoadExample ApplicationsDrop-In ModelsFlush Mount ModelsCC200CC250FCC400F & 600FCC500, 800, 1400 & 2000CC900F, 1300F & 2500FAir-to-Water UnitsCC2060CC3060CC3260CC6360Explosion Proof ModelsCC850-XP & CC1250-XPCC4000CC450RSizing Sheet

Page 3: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact

Cab

inet

Coo

lers

NOREN ProductsInc. 3

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

INTRODUCTION

Noren Products Inc. produces a broad range of heat transfer devices incorporating heatpipes. Several of the company's products are widely recognized by their brand names.They include Compact Cabinet Coolers, Thermal Pins, and Megaflats.The first Noren Heat Pipes were manufactured over 30 years ago. During this time, NorenProducts has successfully solved thermal management problems in the military, machinetool, instrument, robotics, food and power industries, to name a few. The heat pipe is thebasic rapid heat transfer device in all of Noren's cooling products.

What is a real Heat Pipe?

A heat pipe consists of a sealed aluminum or copper container whose inner surfaces have acapillary wicking material. Inside the container is a liquid (usually alcohol) under its ownpressure, that enters the pores of the capillary material, wetting all internal surfaces.Applying heat at any point along the surface of the heat pipe causes the liquid at that pointto boil and enter a vapor state. When that happens, the gas picks up the latent heat ofvaporization. The gas, which then has a higher pressure, moves inside the sealed containerto a colder location where it condenses. Thus, the gas gives up the latent heat ofvaporization and moves heat from the input to the output end of the heat pipe. This processtakes place at great speed reaching over 500 MPH.

One thousand times more conductive than copper of the same weight, heat pipes conductlarge volumes of thermal energy away from the heat source. The heat pipe design is sosimple and efficient that its cooling is advantageous for maintenance retrofit as well as theOEM production application.

Back toTOC

Page 4: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact Cabinet C

oolersNOREN ProductsInc.4

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

The Reliable, Cost Effective Alternative To Cool Sealed Enclosures

Modern day electronics continue to be placed in denser packaging and smaller enclosures.Consequently, electronics are being designed to handle higher temperatures. For example,many industrial logic controllers in today’s market have thermal ratings of at least 140° F.

Moisture and airborne dust, oil, dirt, and other contaminants can damage sensitive electronicequipment. Sealed enclosures protect the electronics but can lead to overheating, whichcauses reliability problems and unnecessary downtime.

The Compact Cabinet Cooler is an air-to-air heat exchanger that solves these problems bycooling and recirculating the clean air inside the cabinet. At the same time, it maintains theenclosure’s protective seal against contaminants.

Air conditioners and other below ambient type coolers are not necessary for most enclosurecooling applications. Compact Cabinet Coolers, built around the heat pipe principle, allow theuse of slightly above-ambient cooling. Cabinet Coolers provide enough cooling even whensummertime temperatures reach 120° F.

GREATER COOLING POWER FOR SEALED ELECTRONIC ENCLOSURES

The Cabinet cooler customer receives many benefits over standard A/C; i.e., smaller size andweight, one-tenth the power draw, longer life and the fact that no condensation is created insidethe cabinet. Also, one hour installation, wiring into the control circuit and easy maintenanceallow the customer to walk away from the Cabinet Cooler after it is installed - worry free. Justchange fans every four or five years.

The Cabinet Cooler’s closed loop design cools and recirculates clean air while isolating sensi-tive components from the hostile environment. Kept in inventory at the manufacturer, standardCabinet Coolers are designed for NEMA 12 type applications.

NEMA 4 and NEMA 4X models are available for operation outdoors or in corrosive environ-ments, when weather protection or external protective coatings are required. Ask our applica-tions engineers for these special protections.

Back toTOC

Page 5: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact

Cab

inet

Coo

lers

NOREN ProductsInc. 5

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

Benefits

• Minimizes down time• Cost savings• Easy to design into existing applications• Easy to retrofit• Worry free operation

Features

• Cools electronics down to slightly above outside ambient air temperature.• Maintains NEMA 12 seal. With added protection, units may be made splash proof (P unit).• Air is circulated inside cabinet to keep hot spots from forming.• Maintenance free cooling. Fans need changing only once in every four years.• Flange and neoprene gasket keep contaminants out.• Easy to install on top, door, sides, or back of cabinet. One person can cut a hole in the cabinet and bolt unit on in less than one hour.• Compact and lightweight. One person can easily carry two units under his arm.• Low power draw. 32 watts per fan results in low operating costs. No new electrical line required.• Causes no condensation like air conditioners.• Corrosion resistant. Anodized aluminum housing (standard). Additional salt water and chemical protection available (please inquire).• Allowable ambient temperature. -40°F to 160°F.• Explosion proof model available.• Oil cooling models available.• 115v 50/60 Hz or 220v 50/60 Hz fans. DC fans also available.

Noren Cabinet Coolers as compared toAir Conditioners are:

• 1/6 the SIZE• 1/7 the WEIGHT• 1/10 the ENERGYand

• 1/5 the COST• FREON FREEand work 13X longer

Back toTOC

Page 6: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact Cabinet C

oolersNOREN ProductsInc.6

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

I. Determine Heat Load

� Existing Cabinets

To find heat load in the cabinet, first determine temperature rise inside the enclosure aboveoutside ambient. Then calculate cabinet surface area available for cooling.

� Measurement and Calculation

1. Seal cabinet.2. Measure T1 inside cabinet air temperature in °F. Measure T2 outside ambient airtemperature approximately 6" from cabinet.3. Calculate surface of cabinet available for free air convection, any surface 3" away from wall.Express surface area in ft2.4. Using (2) and (3) above, heat load in metal cabinet will be:

9 x AREA x (T1 - T2)P (watts)= 36

(Use 2.2 instead of 9 for plastic cabinets.)

� NewCabinets

Several methods are available to the engineer to estimate waste heat load in a newly developedcabinet. Some of the important methods are:

A. Component efficiency.

B. Incoming vs, outgoing power from a bread board unit.

C. Temperature rise and volume of air passing over equipment.

D. Manufacturer’s rating.

E. Simple test of each component.

F. Test in foam or wooden box.

For Computer aided applications assistance, call 650-322-9500 or fax, and we will help you sizeyour enclosure for cooling within two minutes over the phone.

Back toTOC

Page 7: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

7

Know:

P = heat load (watts) from Step IA = surface area of cabinet (ft2)

∆T = allowable rise in temperature above ambient after Cabinet Cooler is installed (°F)

C = Cabinet cooler rating (found in table)

For metal cabinet: C=

Then look in table to find the Cabinet Cooler with at least that capacity (C).

For heat loads requiring more than one Cabinet Cooler to attain desired ∆T, add another

II. Select Correct Model Cabinet Cooler for Individual Applications

36P∆T

- 9A

36P∆T

- 9AC + C =

* Ratings are net values notincluding heat loss through cabinetwalls.

Compact Cabinet Cooler* Rating Table

Watts/20°C∆T(36°F∆T) Installed Unit C CC200 330 CC500 700 CC800 1100 CC1200 1500 CC1400 1500 CC2000 2200 CC250F 322 CC400F 408 CC600F 988 CC900F 1320 CC1300F 1500 CC2500F 2080

Back toTOC

Page 8: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact Cabinet C

oolersNOREN ProductsInc.8

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

• How does the Compact Cabinet Cooler work?

The Compact Cabinet Cooler continuously removes heat from the enclosure’s interior in order to coolsensitive electronic components without exposing them to harsh environments. Referring to theillustration above, the interior fan draws air, which has been heated by the electronics, over the inside halfof the Compact Cabinet Cooler core. The heat pipe core absorbs the heat and transfers it to the outsidefins.

The heat it is removed by the cooler ambient air circulated by the exterior fan. The inside fan blows thecooled air toward the electronic components to cool them. This kind of system is known as an air-to-airheat exchanger.

The heat pipe core of the Compact Cabinet Cooler transfers heat very efficiently. As the core absorbsheat inside the enclosure, the working fluid inside the heat pipes vaporizes and travels to the cooler endof the core, where it gives up its latent heat of vaporization. The exterior fan draws ambient air over thecore and blows the heat away.

The now-cooled fluid condenses and flows back to the hotter end. Notice that the two air streams arekept completely separate. You cool electronic components effectively while protecting them fromenvironmental contamination.

• Example Applications

In example A, we want to cool a NEMA 12, 72" X 36" X 24" uninsulated, floor mounted, sheet metalenclosure. We measured inside cabinet temperature and found it to be 126°F. Outside the cabinet was90°F. Then, from Step 4 on page 3, we calculated heat load (P) to be 600 watts. In this application,allowable temperature rise above ambient (∆T’) is 20°F. Using C=36P/∆T’-9A, we find C=486 watts. Weselect a Cabinet Cooler from the table with a rating of at least 486 watts. Therefore, we choosethe CC500, because it is closest in performance above 486 watts.

In example B, with the same enclosure, if we decrease the allowable rise in temperature to only 10°F,then using C=36P/∆T’-9A again, the Cabinet Cooler rating must exceed 1566 watts. The CC2500F willmeet the requirement.

Choose the first Cabinet Cooler with the rating exceeding that of your heat load. Both standard Drop-inand Flush Mount models are available to accommodate individual enclosure dimensions.Noren’s computer aided application engineers can size your cabinet for cooling in minutes. Providedimensions of the enclosure, inside temperature and outside ambient temperatures (or waste heat load inwatts) for an on-the-spot quotation. Phone 650-322-9500 for information.

• SIMPLE• SMALL• POWERFUL• LONG LIFE

Back toTOC

Page 9: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact

Cab

inet

Coo

lers

NOREN ProductsInc. 9

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

Compact Drop-In Models

Features

Most compact but powerful cooling

1100 - 7500 BTU’s/hr

Energy Efficient. Light Weight.

Fans of 100 - 215 CFM each.

Extends 5 ¾” - 15” respectively into cabinet.

Maintenance Free - Just change fansevery four years.

Quiet - Low dBA

Thin Flush Mount Models

Features

Thin Flush Models

1100 - 3300 BTU´s/hr

Energy Efficient. Light Weight

Fans of 100 - 215 CFM each.

Mounts outside, flush to enclosure

Maintenance Free - Just change fansevery four years.

Quiet - Low dBA

Back toTOC

Page 10: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact Cabinet C

oolersNOREN ProductsInc.10

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

High Power Flush Mount Models

Features

Most poweful Flush Models.

4500 - 7100 BTU´s/hr.

Energy Efficient. Light Weight.

Mounts outside, flush to enclosure.

Maintenace free - just change fans every four years.

Quiet - Low dBA.

Back toTOC

Page 11: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact

Cab

inet

Coo

lers

NOREN ProductsInc. 11

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

Air-to-Water Compact Cabinet Coolers

Below Ambient Cooling System

Features of Noren Water Units

Cools below ambient

3,351, 8,557,9,300 and 21,800 BTU’s/hr respectively

Maintenance free

No filters to clog. No external fans.

Energy efficient - 13, 35 and 100 Watts respectively.

Mounts on the outside, flush mount

Back toTOC

Page 12: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact Cabinet C

oolersNOREN ProductsInc.12

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

CC200

Filters for the dirtiest environments

F20-A F20-P FH-20Washables Disposable Filter Housing

Specifications

Noise LeveldB(A) @ 3 ft.

*230 VAC and 12,24 and 48 VDC Fans also available.

Model EfficiencyWatts/°C

BTU/Hr@20°C∆T

Voltage*

Hz*

Amps No. of Fans& Size

16.5CC200 1100 115 50/60 2 (4”)0.4 50/53

Back toTOC

0 100 200 300 400 500 600

Total Heat Dissipated (Watts)

Insi

de

Tem

per

atu

re R

ise

Ab

ove

Am

bie

nt

(T

)

54°F

45°F

36°F

27°F

18°F

9°F

0°F

30°C

25°C

20°C

15°C

10°C

5°C

0°C

CC200 Insta

lled

Cab

inet

Onl

y

Page 13: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

13Dimensions

Back toTOC

Page 14: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

14

CC500, 800, 1400 & 2000

*230 VAC and 12,24 and 48 VDC Fans also available.

Specifications

Model EfficiencyWatts/°C

BTU/Hr@20°C∆T

Voltage*

Hz*

Amps No. of Fansand Size

Noise LeveldB(A) @ 3 ft.

35.2CC500 2400 115 50/60 2 (6”)0.6 52/56

55.2CC800 3800 115 50/60 2 (6”)0.6 52/5675.0CC1200 5100 115 50/60 2 (6”)0.6 52/5675.0CC1400 5100 115 50/60 3 (6”)0.9 58/62110.4CC2000 7500 115 50/60 4 (6”)1.2 58/62

Filters for the dirtiest environments

F80-AF80-A

F80-PF80-P

FH-80FH-80

F120-AF200-A

F120-PF200-P

FH-120FH-200

F200-A F200-P FH-200

Washable Disposable Filter Housing

Back toTOC

0 1000 2000 3000

Total Heat Dissipated (Watts)

Insi

de

Tem

per

atu

re R

ise

Ab

ove

Am

bie

nt

(T

)

54°F

45°F

36°F

27°F

18°F

9°F

0°F

30°C

25°C

20°C

15°C

10°C

5°C

0°CC

abin

et O

nly

CC

500

Inst

alle

d

CC

800

Inst

alle

d

CC1200

or 1

400

Insta

lled

CC2000 Insta

lled

Page 15: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

15

Dimensions in inchesModel A BCC500 7 1/2 7 1/2CC800 7 1/2 7 1/2CC1200 11 11CC1400 15 7 1/2CC2000 15 15

DimensionsBack to

TOC

Page 16: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact Cabinet C

oolersNOREN ProductsInc.16

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

0 100 200 300 400 500 600

Total Heat Dissipated (Watts)

Insi

de

Tem

per

atu

re R

ise

Ab

ove

Am

bie

nt

(

T)

54°F

45°F

36°F

27°F

18°F

9°F

0°F

30°C

25°C

20°C

15°C

10°C

5°C

0°C

*230 VAC and 12,24 and 48 VDC Fans also available.

Specifications

Model EffiencyWatts/°C

BTU/Hr@20°C∆T

Voltage*

Hz*

Amps No. of Fans& Size

NoisedB(A) @ 3 ft.

16.1CC250F 1100 115 50/60 2 (4”)0.4 50/53

CC250F

Filters for dirtiest environments

F25-A F25-P N/AWashable Disposable Filter Housings

Cab

inet

Onl

y

CC250F Insta

lled

Back toTOC

Page 17: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

17Back to

TOCDimensiones

Page 18: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact Cabinet C

oolersNOREN ProductsInc.18

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

0 500 1000 1500

Total Heat Dissipated (Watts)

Insi

de

Tem

per

atu

re R

ise

Ab

ove

Am

bie

nt

(T

)

54°F

45°F

36°F

27°F

18°F

9°F

0°F

30°C

25°C

20°C

15°C

10°C

5°C

0°C

CC400F and CC600F

Cab

inet

Onl

yC

C40

0F In

stal

led

CC600F Insta

lled

Filters for the dirtiest environmentsWashables Disposables Filter Housing

F40-AF60-A

F40-PF60-P

FH-40FH-60

ModelCC400FCC600F

Especificaciones

Model EfficiencyWatts/°C

BTU/Hr@20°C∆T

Voltage*

Hz*

Amps No. of Fans& Size

Noise LeveldB(A) @ 3 ft.

20.4CC400F 1400 115 50/60 2 (4”)0.4 50/5349.2CC600F 3300 115 50/60 2 (6”)0.6 52/56

*230 VAC and 12,24 and 48 VDC Fans also available.

Back toTOC

Page 19: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact

Cab

inet

Coo

lers

NOREN ProductsInc. 19

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

CC400F Dimensions

Back toTOC

Page 20: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact Cabinet C

oolersNOREN ProductsInc.20

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

CC600F Dimensions

Back toTOC

Page 21: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact

Cab

inet

Coo

lers

NOREN ProductsInc. 21

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

0 1000 2000 3000

Total Heat Dissipated (Watts)

Insi

de

Tem

per

atu

re R

ise

Ab

ove

Am

bie

nt

(T

)

54°F

45°F

36°F

27°F

18°F

9°F

0°F

30°C

25°C

20°C

15°C

10°C

5°C

0°C

*230 VAC and 12,24 and 48 VDC Fans also available.

Specifications

Model EfficiencyWatts/°C

BTU/Hr@20°C∆T

Voltage*

Hz*

Amps No. of Fans& Size

Noise LeveldB(A) @ 3 ft.

66CC900F 4500 115 50/60 2 (6”)0.6 52/56

75CC1300F 5100 115 50/60 2 (6”)0.6 52/56104CC2500F 7500 115 50/60 4 (6”)1.2 58/62

Filters for the dirtiest environmentsWashables Disposables Filter Housing

F90-AF130-AF250-A

F90-PF130-PF250-P

FH-250FH-250FH-250

ModelCC900FCC1300FCC2500F

Cab

inet

Onl

y

CC900F

Inst

alle

d

CC1300

F Insta

lled

CC2500F Insta

lled

CC900F, 1300F & 2500F

Back toTOC

Page 22: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact Cabinet C

oolersNOREN ProductsInc.22

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

CC900F Dimensions

Back toTOC

Page 23: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

23CC1300F and CC2500FDimensions

Dimensions (in inches)

2229

1114.5

ModelCC1300FCC2500F

1926

811.5

1013.5

A B C D E

Back toTOC

Page 24: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact Cabinet C

oolersNOREN ProductsInc.24

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

Below Ambient Coolers

Features of Noren Water Units

• Cools below ambient• 3,351, 8,557, 9,300 and 21800 BTU’s respectively• Maintenance free• No filters to clog• No external fans• Energy efficient - 13, 35 and 100 Watts respectively• Mounts on outside, flush mount enclosure

Requirements

One gallon per minute of circulating water isrequired, from virtually any source. If you havean already low pressure supply, we can help youwork out a simple way to give our cooler the oneGPM it requires without reducing the flow ofother applications.

Condensation

Unlike A/C solutions that create condensation,our water units do not use any refrigerants.Because our units use water, the condensationconcerns are greatly reduced and oftencompletely eliminated.

Safety Factor

Noren air-to-water units are safe. We also manufacture DRY Water solutions. Askour applications engineer for more information.

Back toTOC

Page 25: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact

Cab

inet

Coo

lers

NOREN ProductsInc. 25

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

0 1000 2000 3000

Total Heat Dissipated (Watts)

Insi

de

Tem

per

atu

re R

ise

Ab

ove

Am

ibie

nt

(T

)108°F

90°F

72°F

54°F

36°F

18°F

0°F

60°C

50°C

40°C

30°C

20°C

10°C

0°C

Cab

inet

Onl

yCC20

60 In

stal

led

Typical performance with 1 GPM of cooling water at20°C and ambient air at 40°C when mounted to anuninsulated 72"X36"X24" cabinet.

*230 VAC and 12,24 and 48 VDC Fans also available.

Specifications

Model EfficiencyWatts/°C

BTU/Hr@40°C∆T

Voltage*

Hz*

Amps No. of Fans& Size

Noise LeveldB(A) @ 3 ft.

24.5CC2060 3,351 115 50/60 1 (4”)0.2 Less than 50

Air-to-Water UnitModel CC2060

Back toTOC

Page 26: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

26

CC2060Dimensions

Back toTOC

Page 27: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact

Cab

inet

Coo

lers

NOREN ProductsInc. 27

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

CC2060 Dimensions

Back toTOC

Page 28: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact Cabinet C

oolersNOREN ProductsInc.28

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

0 1000 2000 3000 4000 5000 6000

Total Heat Dissipated (Watts)

Insi

de

Tem

per

atu

re R

ise

Ab

ove

Am

ibie

nt

(T

)

108°F

90°F

72°F

54°F

36°F

18°F

0°F

60°C

50°C

40°C

30°C

20°C

10°C

0°C

Typical performance with 1 GPM of cooling water at20°C and ambient air at 40°C when mounted to anuninsulated 72"X36"X24" cabinet.

*230 VAC and 12,24 and 48 VDC Fans also available.

Especificaciones

Model EfficiencyWatts/°C

BTU/Hr@40°C∆T

Voltage*

Hz*

Amps No. of Fans& Size

Noise LeveldB(A) @ 3 ft.

68.8CC3060 9,300 115 50/60 1 (6”)0.3 Less than 50

Air-to-Water UnitModel Cc3060

Cab

inet

Onl

y

CC3060

Insta

lled

Back toTOC

Page 29: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

29CC3060 Dimensions

Back toTOC

7 x 7.75

Page 30: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact Cabinet C

oolersNOREN ProductsInc.30

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

0 1000 2000 3000

Total Heat Dissipated (Watts)

Insi

de

Tem

per

atu

re R

ise

Ab

ove

Am

ibie

nt

(T

)

108°F

90°F

72°F

54°F

36°F

18°F

0°F

60°C

50°C

40°C

30°C

20°C

10°C

0°C

*230 VAC and 12,24 and 48 VDC Fans also available.

Specifications

Model EfficiencyWatts/°C

BTU/Hr@40°C∆T

Voltage*

Hz*

Amps No. of Fans& Size

Noise LeveldB(A) @ 3 ft.

62.7CC3260 8,557 115 50/60 1 (6”)0.3 Less than 50

Air-to-Water UnitModel CC3260

Typical performance with 1 GPM of cooling water at20°C and ambient air at 40°C when mounted to anuninsulated 72"X36"X24" cabinet.

CC3260 InstalledCab

inet

Onl

y

Back toTOC

Page 31: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

31CC3260 Dimensions Back to

TOC

Page 32: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

32CC3260 DimensionsBack to

TOC

Page 33: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact

Cab

inet

Coo

lers

NOREN ProductsInc. 33

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

0 3000 6000 9000

Total Heat Dissipated (Watts)

Insi

de

Tem

per

atu

re R

ise

Ab

ove

Am

ibie

nt

(T

)

108°F

90°F

72°F

54°F

36°F

18°F

0°F

60°C

50°C

40°C

30°C

20°C

10°C

0°C

Air-to-Water UnitModel CC6360

*230 VAC and 12,24 and 48 VDC Fans also available.

Specifications

Model EfficiencyWatts/°C

BTU/Hr@40°C∆T

Voltage*

Hz*

Amps No. of Fans& Size

Noise LeveldB(A) @ 3 ft.

159.7CC6360 21,800 115 50/60 3 (6”)0.9 Less than 50

Cab

inet

Onl

y

CC6360 Insta

lled

Typical performance with 1 GPM of cooling water at20°C and ambient air at 40°C when mounted to anuninsulated 72"X36"X24" cabinet.

Back toTOC

Page 34: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

34 CC6360 Dimensions

Back toTOC

Page 35: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

35CC6360 Dimensions Back to

TOC

Page 36: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Hazardous Location Applications

Compact Cabinet Coolers™ for a wide variety of Hazardous Locations.

Typical applications

Class I

● Petroleum refineries● Petrochemical companies● Dry cleaning plants● Applications near paint or plastic

spraying● Aircraft hangers, fuel servicing● Utility gas plants

Class II

● Grain elevators, flour, feedmills

● Magnesium, aluminumpowderprocessing

● Chemical, metallurgicalprocesses

● Manufacturing of plastics,medicines, fireworks

● Starch or candymanufacturing

● Coal or carbon handlingprocessing operations

New XP FANS

New XP fans now available for Class 1, Div 2 Group A,B,C and D are available for sale as astand alone product or with the following heat exchangers in purged or non-purgedapplications:

Purged and non-purged applications:

Page 37: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

AIR-to-AIRCC500P, CC800P, CC1200P, CC1400P, CC2000P, CC600FP, CC900FP, CC1300FP,CC2500FP CC4000FP See Use Table Safety: Important Notice

AIR-to-WATERCC3060P, CC3260P CC6360P See Use Table Safety: Important Notice

Purged applications only use:

AIR-to-WATER CC2060P See Use Table Safety: Important Notice

AIR-to-AIR CC851-XP, CC1251-XP See Use Table Safety: Important Notice

Cabinet Cooler Use in Hazardous Locations

 DIVISION 1

(Hazard is normally present)

DIVISION 2

(Hazard is not normally present)

 PurgeType →

X purge Y purge Z purge None (no purge)

 

CabinetCooler Type * →

XP A/W XP

 +

IHL

A/W

+

IHL

XP

 

A/W

 

HL

 

XP

+

IHL

A/W

 +

IHL

HL2

CLASS 1                    

GROUP A:Acetylene

No 2060P3060P3260P6360P

No 3060P-IHL,

3260P-IHL,

6360P-IHL

No 2060P3060P3260P6360P

CC500,800,

1200,1400,

&   2000P-HL.

CC600F,900F,

1300F,2500F,

&4000FP-

HL

No 3060P-IHL,

3260P-IHL,

6360P-IHL

CC500,800,

1200,1400,

&   2000P-HL2.

CC600F,900F,

1300F,2500F,

& 4000FP-HL2

Page 38: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

GROUP B:Hydrogen,ManufacturedGas, etc.

No** 2060P3060P3260P6360P

No** 3060P-IHL,

3260P-IHL,

6360P-IHL

No** 2060P3060P3260P6360P

CC500,800,

1200,1400,

&   2000P-HL.

CC600F,900F,

1300F,2500F,

&4000FP-

HL

No** 3060P-IHL,

3260P-IHL,

6360P-IHL

CC500,800,

1200,1400,

&   2000P-HL2.

CC600F,900F,

1300F,2500F,

& 4000FP-HL2

GROUP C:Diethyl ether,ethylene,cyclopropane,etc.

851XP

1251XP

2060P3060P3260P6360P

851XP-IHL

1251XP-IHL

3060P-IHL,

3260P-IHL,

6360P-IHL

851XP

1251XP

2060P3060P3260P6360P

CC500,800,

1200,1400,

&   2000P-HL.

CC600F,900F,

1300F,2500F,

&4000FP-

HL

851XP-IHL

1251XP-IHL

3060P-IHL,

3260P-IHL,

6360P-IHL

CC500,800,

1200,1400,

&   2000P-HL2.

CC600F,900F,

1300F,2500F,

& 4000FP-HL2

GROUP D:Gasoline,hexane,butane,naphtha,propane,toluene,isoprene,alcohol,acetone,lacquersolvent,natural gas,etc.

851XP

1251XP

2060P3060P3260P6360P

851XP-IHL

1251XP-IHL

3060P-IHL,

3260P-IHL,

6360P-IHL

851XP

1251XP

2060P3060P3260P6360P

CC500,800,

1200,1400,

&   2000P-HL.

CC600F,900F,

1300F,2500F,

&4000FP-

HL

851XP-IHL

1251XP-IHL

3060P-IHL,

3260P-IHL,

6360P-IHL

CC500,800,

1200,1400,

&   2000P-HL2.

CC600F,900F,

1300F,2500F,

& 4000FP-HL2

CLASS 2                    

GROUP E:Flammablemetalpowders, etc.

(S)

851XP

1251XP

2060P3060P3260P6360P

No No (S)

851XP

1251XP

2060P3060P3260P6360P

No No No No

Page 39: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

GROUP F:

Carbon black,coal dust,coke dust, etc.

851XP

1251XP

2060P3060P3260P6360P

No No 851XP

1251XP

2060P3060P3260P6360P

No No No No

GROUP G:

Flour, starch,grain dust,etc.

851XP

1251XP

2060P3060P3260P6360P

No No 851XP

1251XP

2060P3060P3260P6360P

No No No No

NOTES:

All Cabinet Cooler models for Hazardous Location duty are pressure tested (P suffix) toassure a liquid tight and airtight seal.

Type X purging changes the interior hazard class of the enclosure from Div. 1 to non-hazardous.

Type Y purging changes the interior hazard class of the enclosure from Div. 1 to Div. 2.

Type Z purging changes the interior hazard class of the enclosure from Div. 2 to non-hazardous.

 

*Cabinet Cooler Types:

XP: Air to Air Unit with external Explosion Proof blower (internal fan is standard duty).Models: CC851XP, CC1251XP. Voltage: 115 or 230 VAC.

A/W: Air to Water unit with no external electrical or moving parts (internal fan is standardduty). Models: CC2060P, CC3060P, CC3260P, CC6360P. Voltage: 115 or 230 VAC, 12, 24,or 48 VDC.

IHL: Air to Water or XP Unit with Internal Hazardous Location fan(s): Air to Water models:CC3060P-IHL, CC3260P-IHL, and CC6360P-IHL.  XP models include CC851XP-IHL,CC1251XP-IHL. Voltage: 115 VAC.

HL: Air to Air Unit with external Hazardous Location Fan(s). Models: CC500P-HL, CC800P-HL, CC1200P-HL, CC1400P-HL,    CC2000P-HL, CC600FP-HL, CC900FP-HL, CC1300FP-HL, CC2500FP-HL, CC4000FP-HL. Voltage: 115 VAC.

HL2: Air to Air Unit with external and internal Hazardous Location Fan(s). Models:CC500P-HL2, CC800P-HL2, CC1200P-HL2, CC1400P-HL2, CC2000P-HL2, CC600FP-HL2, CC900FP-HL2, CC1300FP-HL2, CC2500FP-HL2, CC4000FP-HL2. Voltage: 115 VAC.

Page 40: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

No = Not usable

** = Explosion Proof Blowers for this environment may be available in the future.

(S) = Special order

---------------------------------------------------------------------------------------------------------

SAFETY: IMPORTANT NOTICE

USING NOREN “XP”, “HL”, “HL2”, “-IHL”, AND “AIR TO WATER” CABINETCOOLERSTM IN HAZARDOUS LOCATIONS

 

1.     Only use HL2 Cabinet CoolersTM without purged / pressurized systems if an internalDiv 2 hazard condition is allowable. All fans are rated for Division 2 use.

2.     Only use “Air to Water type IHL” Cabinet CoolersTM without purged / pressurizedsystems if an internal Div 2 hazard condition is allowable. The Internal Hazardous Locationfan(s) are rated for Division 2 use.

3.     Always use standard Noren “HL” Cabinet CoolersTM in conjunction with type Z purged/ pressurized systems. The internal fan is not rated for hazardous use.

4.     Noren “XP type IHL” and “Air to Water type IHL” Cabinet CoolersTM have InternalHazardous Location fans rated for Division 2 use. This may permit the use of a Type Ypurging system in Division 1 Locations if an internal Division 2 hazard condition isallowable.

5.     Always use standard Noren “XP” or standard “Air to Water” Cabinet CoolerTM inconjunction with type X or type Z purged / pressurized systems.

6.     Never use standard Noren “XP”, “HL”, or “Air to Water” Cabinet CoolerTM with type Ypurged / pressurized systems. The internal fan is not rated for Div 2 use.

7.     Only use Noren “XP” or “HL” Cabinet CoolersTM in locations for which the external XP(eXplosion Proof) or HL (Hazardous Location) motor is designed.

8.     Read the hazard classification on nameplate of the motor(s) you receive to assure theyare appropriate for your application.

9.     Noren “Air to Water” Cabinet CoolerTM can be used in some hazardous locations whereNoren XP or HL units cannot. Depending on which internal fan is used and your purgingsystem, this may include Class 1, Div 1, Groups A & B (acetylene, hydrogen, manufactured

gas). “Air to Water” Cabinet CoolesTM have no external electrical or moving parts.

Page 41: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

10.  Noren Cabinet CoolersTM will not maintain the explosion proof integrity of NEMA 7type enclosures.

11.  It is the customer’s responsibility to know what protection their purged / pressurized

system provides. Install the Noren Cabinet CoolerTM correctly and safely in accordance withthe National Electrical Code (N.E.C.)

Page 42: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact

Cab

inet

Coo

lers

NOREN ProductsInc. 37

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

Models CC851XP and CC1251-XPExplosion Proof Units

Especificaciones

Model

CC850-XPCC1250-XP

EfficiencyWatts/°C

BTU/Hr@20°C∆T

Voltage*

Hz*

Amps Weight Dimensions extendinginto cabinet

60 3700 115 50/60 50 lbs.5 7 1/2

80 5000 115 50/60 51 lbs.5 11

0 500 1000 1500 2000 2500 3000

Total Heat Dissipated (Watts)

Insi

de

Tem

per

atu

re R

ise

Ab

ove

Am

bie

nt

(T

)

54°F

45°F

36°F

27°F

18°F

9°F

0°F

30°C

25°C

20°C

15°C

10°C

5°C

0°CCC85

1

-XP

Inst

alle

d

Cab

inet

Onl

y

CC125

1

-XP In

stalle

d

Back toTOC

Page 43: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact Cabinet C

oolersNOREN ProductsInc.38

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

CC850 and CC1250-XP Dimensions

Back toTOC

Page 44: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

39

CC851 and CC1251-XP Dimensions

Back toTOC

Page 45: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact Cabinet C

oolersNOREN ProductsInc.40

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

������ �����

�������

���� �� �� ������������� ����������������� ��� ��� �������������� ������ � � ������!

������

���"��#

������#

���$��#�

�����#�

�����#

$��#

���%�&'�!�(��#����%)��*���+�, ���+������-�� ��

)

$�$#���%

.����%

�)���%%"�

%����.%����%

%�

�.���%

����%��.

����

New ModelsNoren’s Largest Standard Compact Cabinet Cooler

Customer demand drives the Noren engineering to develop the CC4000. Still a compact model,it removes twice the heat as the CC2500F. Larger model are in development.

������������

����/0��� � ��1+2��3

���456+2)%7 ∆5

�����8�

9*�

����

��:!�;�9 <=

��>�?� �;��7@�A6�

�� �3

:))).++ )!))% )))B�� $�� )#�)$ #!� @C#A� %#��$ !,��.

� ��,�� �>������:+&8�.���.%B%����+�8)�%

stnemnorivnetseitridehtrofsretliF

ledoM elbahsaW elbasopsiD gnisuoHretliF

F0004CC redrOlaicepS

Back toTOC

Page 46: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact

Cab

inet

Coo

lers

NOREN ProductsInc. 41

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

#!"$�

�"�

�!))/��!

�!�

%��/ � ���

.!.$�

�!$)&��

%!))/ �!

%!���&��.!��

%%!%$

%)!�%

D��� ��6��

%!�%

)

)!$)) "!#��)!��

E���� E����

+���� �

+���� �

/��� ������

"��%A)!%�@�(.�/��� ���*���

������

Remote Surface Mount

This special model was developed for a customer that is not able to mount a cabinetcooler on the enclosure. Especially thin cabinets or small cabinets are perfectcandidates for the CC450R.

������������

����/0��� � ��1+2��3

���456+2)%7 ∆5

�����8�

9*�

����

��:!�;�9 <=

��>�?� �;��7@�A6�

�� �3

E)$.++ )!)% )).� $�� )#�)$ .! @C#A� �$�)$ !,�$�

� ��,�� �>������:+&8�.���.%B%����+�8)�%

stnemnorivnetseitridehtrofsretliF

ledoM elbahsaW elbasopsiD gnisuoHretliF

R054CC 54F A54F P54F

Back toTOC

Page 47: Compact Cabinet Coolers - globalmetech.com · Air conditioners and other below ambient type coolers are not necessary for most enclosure cooling applications. Compact Cabinet Coolers,

Com

pact Cabinet C

oolersNOREN ProductsInc.42

Noren Products, Inc.1010 O'Brien Drive, Menlo Park, CA 94025

(650)322-9500 Fax: (650)324-1348http://www.norenproducts.com

CALL, FAX OR EMAIL US TO COOL YOURSEALED ELECTRONIC ENCLOSURES

THESE ARE SOME OF THE AVAILABLE FEATURES:

- NEMA 4, NEMA 4X, NEMA 12 - Stainless Steel- Explosion Proof - Interior Mount- UL Recognized units are Available in Nema 12

!!!OBTAIN A FAST COOLING SOLUTION FOR YOUR CABINET!!!WE MANUFACTURE SPECIAL UNITS TO SOLVE CUSTOM APPLICATIONS

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Call, Email or send us a fax. We will help you size your enclosure for cooling within two minutesover the phone.

DATE: _______________________NAME: _____________________________________________COMPANY: _______________________________________________________________ADDRESS: ______________________________________________________________CITY: ________________________________ STATE: _________________________ZIP CODE _______________PHONE NUMBER: ____________________________________FAX NUMBER ___________________________________________EMAIL ADDRESS_________________________________________

SIZE OF CABINET:

HEIGHT: _______ WIDTH __________ LENGTH __________

*INTERIOR TEMPERATURE INTERIOR OF CABINET ____ ° F

HEAT LOAD ________BTU/HR.

*AMBIENT TEMPERATURE OUTSIDE OF CABINET ____° F

OR _________ WATTS(*) Taken simultaneously

For Air-to-Water Applications: Water Temperature _________°F

Email us at: [email protected]

Back toTOC


Recommended