KEW 6305POWER METER
Compact Power meter for cost savings through Energy monitoring
●Comprehensive real-time monitoring, record-ing and analysis of single and 3-phase systems
●Voltage, Current, Power Factor and Frequency measurements
●Power analysis (Active, Apparent and Reactive power)●Energy analysis (Active, Apparent and Reactive energy)●Active power accuracy: ±0.3%rdg±0.2%f.s.●Automatic wiring check function to prevent incor-
rect connections
●Large memory capability (2 GB) using built-in SD card interface
●Real time & remote measurements using Android application●Windows software for data analysis and setting via USB
port or Bluetooth●Synchronous measurements between two units of KEW6305●Wide selection of clamp sensors allow measurements
from 0.1A to 3000A●The instrument automatically recognizes what kind of
clamp sensor is connected to it
A simple and inexpensive way for Cost Savings through Energy monitoring
Rotate the Rotary switch to SET UP. All the instrument settings can be easily selected by using instrument buttons. All the settings can also be selected by connecting KEW6305 to a PC via USB or Bluetooth.
Starting from OFF position and rotating the Rotary switch clockwise, KEW6305 is ready to use in 3 simple steps
1. SET UP
Rotate the Rotary switch to WIRING CHECK. The Automatic Wiring check func-tion will prevent incorrect connections, check the connections and display the results on the LCD.Error messages appear on display to indicate wrong orientation of Clamp sen-sors or incorrect connections.
Everything is OK Error is found
Rotate the Rotary switch to W/Wh/DEMAND. The instrument can performInstantaneous, Integration and DEMAND measurements.START / STOP button to start / stop recording
Two units of KEW6305 can be used simultaneously and perform synchronous measurements on 2 power lines.PC software application can synchronize recording intervals and internal clocks of two KEW6305 via Bluetooth communication or USB port. Measurements will be transmitted to the PC.Parameters such as active, reactive and apparent power; active, reactive and apparent energy and demand will be graphically displayed in real-time. * For wireless communication, a PC with Bluetooth function is required.
Combined values will be displayed on a graph in real-time. Real-time display
Measurements can be displayed in graphic or numeric forms on Android devices in real-time via Bluetooth communication.Remote checking of measurements is possible without accessing KEW6305.
Max communication distance: 10mSupporting Android ver. 3.0 or higher.Bluetooth is a registered trademark of the Bluetooth SIG, Inc.Android and Android Market are registered trademark of the Google SIG, Inc.
2. WIRING CHECK
3. W/Wh/DEMAND Measurements
PC software application to check synchronous measurements on 2 power lines Real time & remote measurements using Android application
As easy as 1 ➜ 2 ➜ 3 !
Various measurements by using applications for PCs and Android devices
➜
➜
Shows “Err” (Error) e.g.: Err PH A➔Current phase (orientation of sensor) may be incorrect.
Shows “Good”
Current Input Terminals (With cover)
Voltage Input Terminals
A simple and inexpensive way for Cost Savings through Energy monitoring
Max amount of data (reference)
Voltage (True RMS), Current (True RMS), active power, apparent power, reactive power, active energy, apparent energy, reactive energy, power factor (cosθ), frequency, demand measurement, current flowing on the neutral line (only on 3phase 4 wire measurement)
Data saved on an SD card or internal memory of KEW6305 can be directly transferred to a computer via USB. USB ver. 2.0 is supported.
1/2/5/10/15/20/30 second/seconds 1/2/5/10/15/20/30 minute/minutes 1hour
SD cards up to 2GB can be used.
*in case the SD card is empty
Not only the total power and power factor are shown but also the breakdown related to each phase
The last 10 measurements saved on SD card or internal memory are displayed on the LCD.This function allows quick checks of the recorded data without using a PC.
In case of a mains blackout, the power to the instrument is automatically supplied by the Alkaline batteries (Max continuous measurement: 15 hours)In the case of both power supplies to the instrument being interrupted, recorded data just before the event of the interruption will be saved. Rechargeable nickel-hydrogen batteries can be used
Automatic creation of graph and list from recorded data.Uniform management of setting and recorded data acquired from multiple devices.Data can be expressed in crude oil and CO2 equivalent values in the report.
Tablet device
Power and Energy measurements
Data transmission via USB
Recording interval can be set between 1 second and 1 hour
SD card Interface
Power and the power factor for each phase are shown
Data check
Double power supply system via AC line and batteries
Windows software for data analysis and setting via USB port
Real time & remote measurements using Android application
Data can be saved on SD card or transferred to a PC
FeaturesVarious measurements by using applications for PCs and Android devices
【System requirements】OS: Windows® 7/8/10Display: XGA(Resolution 1024×768 dots) or moreHard-disk: space required 1Gbyte or moreOther: With CD-ROM drive and USB port .NET Framework (3.5 or more)* Windows® is a registered trademark of Microsoft in the United States.
Data saved on: SD cardInternalmemory
Capacity 2GB 3MBInstantaneous measurement 6,670,000 10,000
Integration / demandmeasurement interval
1 sec. 17 days 33 minutes1 min. 992 days 33 hours
30 min. 3 years or more 42 daysMax number of file 511 4
For inquires or orders :
Safety Warnings :Please read the "Safety Warnings" in the instruction manual supplied with the instrument thoroughly and completely for correct use. Failure to follow the safety rules can cause fire, trouble, electrical shock, etc. Therefore, make sure to operate the instrument on a correct power supply and voltage rating marked on each instrument.
The contents of this leaflet are subject to change without notice. KEW 6305-2E Feb. 19 AD
2-5-20, Nakane, Meguro-ku, Tokyo, 152-0031 JapanPhone:+81-3-3723-0131Fax:+81-3-3723-0152E-mail:[email protected]
NEW
Wiring connections 1P2W, 1P3W, 3P3W, 3P3W3A, 3P4W
Measurements Voltage, Current, Frequency, Active power
Parameters Apparent power, Reactive power, Active energy, Apparent energy, Reactive energy, Power factor (cos θ), Neutral current
Voltage range 150.0/300.0/600.0V
Voltage accuracy ±0.2%rdg±0.2%f.s. (sine wave, 45 - 65Hz)
Current range 10.00/50.00/100.0/250.0/500.0A/Auto (with clamp sensor MODEL8125)
Current accuracy ±0.2%rdg±0.2%f.s.+ Accuracy of Clamp sensor (sine wave, 45 - 65Hz)*+1%f.s. at the lowest range.
Effective input range 10 - 110% of rating range
Display range 5 - 130% of each range (Voltage)1 - 130% of each range (Current)
Crest factor Voltage : up to 2.5, Current : up to 3.0 (with 90% fs or less)
Active power accuracy ±0.3%rdg±0.2%f.s.+ Accuracy of Clamp sensor*+1%f.s. when the lowest current ranges is selected.
Effect of power factor Active power: ±1.0%rdg cos θ=±0.5 (PF=1)
Frequency meter range 40.0 - 70.0Hz
Frequency meter accuracy ±3dgt
Accuracy precondition PF=1, Sine wave, 45 - 65Hz, 23℃±5℃
Display update period 1 second
Operating temperature and humidity range 0 - +50℃, less than 85% RH (without condensation)
Storage temperature and humidity range -20 - +60℃, less than 85% RH (without condensation)
PC communication interface USB, Bluetooth
PC card interface SD card (2GB)
Safety standard IEC 61010-1 CAT Ⅲ 600V
Power source (AC Line) AC100 - 240V±10%(50/60Hz)
Power source (DC battery) LR6 or Ni-MH (HR-15-51)×6 (Battery charger not included), Battery life approx. 15h (LR6)
Power consumption 10VA (max.)
DimensionWeight
175 (L)×120 (W)×65 (D)mmApprox. 800g (including batteries)
Included accessories
7141B (Voltage test lead set: 4pcs), 7148 (USB cable),7170 (Powercord), 9125 (Carrying case for KEW 6305, KEW 6305-01), 9135 (Carrying case for KEW 6305-03, KEW 6305-05), 8326-02 (SD card 2GB), KEW Windows (PC Software), Battery (LR6)×6, Quick manual
Optional accessories8124, 8125, 8126, 8127, 8128 (Clamp sensor),8130, 8133 (Flexible clamp sensor),8312 (Power supply adaptor), 9132 (Magnetic carrying case)
MODEL 9132
MODEL 8312
MODEL 8128 MODEL 8127 MODEL 8126 MODEL 8125 MODEL 8124
MAX50A φ24 MAX
100A φ24 MAX200A φ40 MAX
500A φ40 MAX1000A φ68
KEW 8130 KEW 8133
MAX1000A φ110 MAX
3000A φ170
● KEW 6305 Specifications
Load current clamp sensors
Power supply adaptor
Magnetic carrying case
Load current flexible clamp sensors
Optional
Set Model
For taking single phase supply (100-240V) from the test leads to power the instrument
For mounting inside metal distribution boards
KEW 6305-01MODEL 8125 (500A) × 3(Carrying case 9125)
KEW 6305-03KEW 8130 (1000A) × 3(Carrying case 9135)
KEW 6305-05KEW 8133 (3000A) × 3(Carrying case 9135)
Can you close your distribution board door during surveys?The KEW6305 facilitates safe testing by being extremely com-pact and with two clever option extras: a magnetic case for attaching it to the sides of metal enclosures and a power supply adaptor which takes the power for the instrument from the sup-ply being measured.
Photo: KEW6305-03