Prof. Dr. Endre Varga Balázs Erdőhelyi University of Szeged Albert Szent-Györgyi Clinical Center Department of Trauma Surgery and Department of Image Processing and Computer Graphics Computer Assisted Image Processing and Navigation Systems for Trauma Surgery (Making our life easier)
Transcript
Page 1: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Prof. Dr. Endre Varga Balázs Erdőhelyi

University of Szeged Albert Szent-Györgyi Clinical Center

Department of Trauma Surgery and

Department of Image Processing and Computer Graphics

Computer Assisted Image Processing and Navigation Systems for Trauma

Surgery (Making our life easier)

Page 2: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Our duty

Page 3: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Sheet

Once upon a time…1956

What they had?

Huge practise

Page 4: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Sheet

Once upon a time…

What they had?

Huge practise More respect?

„„„

Page 5: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Sheet

1993-94 Canada

“With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic ring injury will become safer and will, I believe, become the method of choice for early stabilization.”

(Marvin Tile, Foreword. Injury, Supplement, Pelvic Ring Injuries, Part II, 1996, Vol.27, Suppl. 2)

„„„

Page 6: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Sheet

Today - what else?

Page 7: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Sheet

Today - what else?

• Good light • Good power tools (Light, oscillating drills)

llii ht

Page 8: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Sheet

Today - imaging

• Conventional x-ray • 3-D C-arm • CT scan • Spiral CT scan • MRI • Ultrasound • Arthroscopy (optical imaging) • Radioisotope scan • Navigation • Preop. Planning

Page 9: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

History

Page 10: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Take home

10

Page 11: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Literature

new challenge, different evidence levels

Page 12: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Smartphones/tablets

Page 13: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Today trends

Page 14: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Offer an Idea

Last 19 years TEAM work IT experts (software designers) medical doctors engineers

focused education

Page 15: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Planning softwares on the market

Non competitive

No FEA

No animation

Not 3D

Page 16: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Maybe the plan was wrong? - Interactive 3D-plan

Page 17: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Should be plan!

Page 18: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic
Page 19: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic
Page 20: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

What are the strengths of ?

•Team with same interest (common language)

•AO trained clinicians and mathematicians

•The Trauma Department, U of Szeged is a dedicated AOTrauma Educational Center - aim to be an AO Research Site as well

•Surgeons and computer experts are working “hand in hand”

•Wide international connections

Page 21: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Endre Varga, MD, PhD. Professor of Trauma Surgery, University of Szeged, HungaryLevel I Trauma Center

general-, trauma-, orthopedic- & hand-surgeonPresident of Hungarian Trauma SocietyAO TrusteePresident of the AOTrauma Hungarian ChapterChair of ATLS HungaryHungarian delegate of ESTES

87 Fellowship, Martin Luther University, Halle, Germany93-94 Fellowship at Sunnybrook Health Science Centre, Toronto, Canada (Biomechanical research)96 AO Fellowship at Carolinas Medical Center, Charlotte NC, USA

Page 22: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

ARI Research Fellowship

Balázs Bagó Szeged, Hungary Computer Science

Fellowship March 2011 - December 2011

Endre Varga jr. DMD Szeged, Hungary Doctor in Dentistry

Fellowship March 2010 - March 2011

Balázs Erdőhelyi Szeged, Hungary Computer Science

Fellowship August 2010 - January 2011 Co-worker 11 August 2011- June 2012

more than 3 years!!!

Page 23: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

CT 3D Biomech.

Segmented

Image

3D Surface

model

Implants

Surgical

Plan

Mechanical

data

Biomech.

model

CT image

FEA

Analysis

Operating Room Navigation

The whole idea

Page 24: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

CT 3D Biomech.

Segmented

Image

3D Surface

model

Implants

Surgical

Plan

Mechanical

data

Biomech.

model

CT image

FEA

Analysis

Operating Room Navigation

The idea

CCCCCCCCCCTTTTTTTTTTTTTTTTT iiiiiiiiiiimmmmmmmmmmmmmmmmmmmmmaaaaaaaaaaaaaaaaaaaaaaaaaagggggggggggggggggggggggggeee

33 h

hhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhh.....

nnnnnnnnnnnnnniiiiiiiiiiiiiiiiiiiiiiiiiiiiccccccccccccccccaaaaaaaaaaaaaaaaaaaaaaaallllllllllllllllllllllllllll FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

c

S

33

m

cc

nnnnnnnnnnnnnnn

CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT 333333333333333333333333333333333333333333333333333333333333333DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiioooooooooooooooooooooooommmmmmmmmmmmmmmmmmmmmm

SSSSSSSSSSSSSSSSSSSSSSSeeeeeeeeeeeeeeeeeeeeeegggggggggggggggggggggggggggggggggggmmmmmmmmmmmmmmmmmmmeeeeeeeeeeeeeeeeeeennnnnnnnnnnnnnnnnnnnnnnnnnnnnnttttttttttttttttteeeeeeeeeeeeeeeedddddddddddddddddddddd

Immmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmaaaaaaaaaagggggggggggeeeeeeeee

SSSSSSSSSSSSSSSSSSSSSSSSSSSuuuuuuuuuuuuuuuuuuuuuuuurrrrrrrrrrrrrrrrrrrrrrrrrrrrrffffffffffffffffffffffffffffffffffffffffffaaaaaaaaaaccccccccccccccccccccccccceeeeeee

ddddeeeeeeeeeeeeeeeeeeelllllllllllllllllllll

IIIIIIIIIIIIIIIImmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmppppppppppppppppppppppppppppppppppppplllllllllllllllllllllllllaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnntttttttttttttttttttttsssssssssssssssssssssssssssssssss

SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuurrrrrrrrrrrrrrrrrrrrrrrrrrrgggggggggggggggggggggggggggggggggggggggiiiiiiiiiiiiiiiiiiiiiiiiicccccccccccccccccccccaaaaaaaaaaaaaaaaaaaaaaallllllllllllllllllllllllllllllll

PPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPlllllllllllllllllllllllaaaaaaaaaaaaaannnnnnnnnnnnnnnnnnnn

MMMMMMMMMMMMMeeeeeeeeeeeeeeeeeeeeeecccccccccchhhhh

ddddddddddddddddddddddddddddddddddaaaaaaaaattttttttaaaaaaaaaaaaa

BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBiiiiiiiiiiiiiiiiiiiiiioooooooooooooooooooommmmmmmmmmmmmmmmmmmmmmmmmmmmeeeeeeeeeeecc

mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmoooooooooooooooooooooooooooooooooooooooddddddddddddddddddddddddddddddddddddddddddddddddddddddddeeeeeeeeeeeeeellllllll

SSSSSSSSSSSSSSS

dddddddddd

33333DDDDDDDDDDDDDDDDDDDDDD SSSS

mmmmmmmmmmmmmmmmooooooooooooooooooooooooddddddddddddddddddd

mmmmmmmmmmmmmmmmm

hhhhhhh

mmmmmmmmmmmmmmeeeeeeeeeecccc

aaaaaaaaaaaannnnnnnnnnnnnnnnnnnnn

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnaaaaaaaaaaaalyyysssiiiiiiiiiisss

NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaavvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvviiiiiiiiiiiiigggggggggggggggggaaattttiiiiiiiiiiiiiiiiiiiiiiiiiioooooonnnnnnn

Page 25: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Segmen-tation

SurfaceExtraction

MechanicalModel

Generation

ResultEvaluation

Analysis

Surgical Planning

CT

JMed

FEA

System Overview - CT

Page 26: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Segmen-tation

SurfaceExtraction

MechanicalModel

Generation

ResultEvaluation

Analysis

Surgical Planning

CT

JMed

FEA

System Overview - Segmentation

Page 27: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Marching Cubes ~800k triangles

ss

Simplification ~100k triangles

Segmen-tation

SurfaceExtraction

MechanicalModel

Generation

ResultEvaluation

Analysis

Surgical Planning

CT

JMed

FEA

System Overview – Surface Extraction

Page 28: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Segmen-tation

SurfaceExtraction

MechanicalModel

Generation

ResultEvaluation

Analysis

Surgical Planning

CT

JMed

FEA

System Overview – Surgical Planning

Page 29: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Segmen-tation

SurfaceExtraction

MechanicalModel

Generation

ResultEvaluation

Analysis

Surgical Planning

CT

JMed

FEA

System Overview – Mechanical Model

Page 30: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Segmen-tation

SurfaceExtraction

MechanicalModel

Generation

ResultEvaluation

Analysis

Surgical Planning

CT

JMed

FEA

System Overview – Result

Page 31: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

SzE, 50yFemale

Fall from high

Acetabulum

Page 32: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Acetabulum

Page 33: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic
Page 34: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic
Page 35: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Intraop

Page 36: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

TraumArt on the screen

Page 37: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

low profile plates

Page 38: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Case presentation (planning and procedure)

Page 39: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Segmen-tation

SurfaceExtraction

MechanicalModel

Generation

ResultEvaluation

Analysis

Surgical Planning

CT

JMed

FEA

Planning

Page 40: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic
Page 41: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic
Page 42: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

1. Register and login. 2. Create a Study. 3. Pre-operative survey. 4. Upload DICOM files. 5. View results. 6. Post-operative survey.

Service and clinical trial http://www.inf.u-szeged.hu/~medsys/service.php

Page 43: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

• Users: 25 different countries

• Countries: Europe and Australia, USA, Columbia, Saudi Arabia, Canada.

Present status

Page 44: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Italian Case

Page 45: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic
Page 46: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic
Page 47: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic
Page 48: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic
Page 49: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic
Page 50: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic
Page 51: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic
Page 52: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic
Page 53: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic
Page 54: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic
Page 55: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic
Page 56: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Italian Case

Page 57: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Italian Case with VCP

Page 58: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Italian Case with juxtaartic-LCP

Page 59: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

It. Case with 2 col dorsal plates

Page 60: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Italian Case VA-LCP

Page 61: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Case VA-LCP

Page 62: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

VA-LCP focused on key screws

Page 63: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Postoperative Xrays

Page 64: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Postoperative Xrays

Page 65: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Spine16y/ female/ horseriding No neurological compl.

Page 66: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Spine

Page 67: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Spine

Page 68: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Spine

Page 69: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

CMF - case

Page 70: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Glider Truck crush

Page 71: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Glider Truck crush

Page 72: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Glider Truck crush

Page 73: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Glider Truck crush

Page 74: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic
Page 75: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Intermediate splint - rapid prototype

Page 76: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Human

CT

image

FEA

Analysis

Educational platform first step

Animation

AO Surgery reference

Page 77: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Simplify the question Injury animation - surgery reference

Be a surgeon! Play with forces

Page 78: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Straddle fx

Page 79: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Bucket handle fx

Page 80: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

AP (B1) HD Risk ++

Page 81: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

LC (B2) H/D Risk +/-

Page 82: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

VS (C) H/D Risk ++/-

Page 83: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Injury animation - surgery reference

On site support

Sequential introduction

International development with experts involvement

Page 84: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Bone defect allograft library

Page 85: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Implant design

Page 86: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Injury animation - surgery referenceCooperation with ARI

Page 87: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

PublicationsB Erdőhelyi, E Varga and A Kuba (2007) Surgical Planning Tool with Biomechanical Simulation. Int J CARS 2 (Suppl 1):S246–S272

E. Varga, B. Dudás, and M. Tile (2008) Putitative prorioceptive function of the pelvic ligaments: Biomechanical and histological studies Injury Vol.39, pp. 858-864.

E. Varga, B. Erdőhelyi (2010) Severe Pelvic Bleeding: The Role of Primary Internal Fixation European Journal of Trauma and Emergency Surgery, NO.2 pp. 107-116

ncycy

Page 88: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

• 1. EDUCATION: Implementing the program into the AOSurgery Reference (animations)

• 2. CLINICAL: Validate the Program with the help of German Trauma Registry cases (C. Krettek - 20T/20 CMF- pilot)

• Evaluate webclinical feedbacks

• 3. R&D: Further development in cooperation with the ARI

Future steps

Page 89: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

EU Grant GOP 1.1.1. Siemens ARCADIS ISO C 3D Image Intensifire, BrainLab IO Navigation Unit.

Pelvis, Acetabulum, Spine, Joints surgeries

Page 90: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

TRAUMA TEAM

Page 91: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Sheet

What is different in the OR?

Page 92: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Sheet

Light…

Page 93: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

MonitorMonitor

Carbon/ARCADIS/BrainLab/Carbon op table

Page 94: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Sheet

Today - imaging

• Conventional x-ray • 3-D C-arm • CT scan • Spiral CT scan • MRI • Ultrasound • Arthroscopy (optical imaging) • Radioisotope scan • Navigation • Preop. Planning

Page 95: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Sheet

Today - what else?

• Good light • Good power tools (Light, oscillating drills)

Page 96: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

SummaryVarious imaging modalities exist…

• Conventional x-ray: adequate for most bone injuries • 3-D C-arm: intraoperative assessment of reduction and

fixation • CT scan: imaging of complex intraarticular fractures • Spiral CT scan: polytrauma • MRI: deep soft-tissue lesions

• IO Navigation and CT and • 3D Virtual Planning improved patient

care

Modalities

Page 97: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Sheet

Conventional X-ray (Image intensifire)

Limits Some fractures and subluxations difficult to see Poor visualization of soft tissues Potentially insufficient information for planning

Page 98: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Sheet

Conventional X-ray (Image intensifire)

Limits Some fractures and subluxations difficult to see Poor visualization of soft tissues Potentially insufficient information for planning

Page 99: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

Modified C-Arm with a motor unit allows steady orbital rotation around 190° arc

Modified C-Arm with a motorttststssteaeaeaeadddydydydy ooo o bbrbrbrbrbitititittit llalalaal rrr r ttotototot ttatataatiiioiooionnnn araraarouououou

13 cm³

Intraoperative ISO C 3D ARCADIS

Modified C-Arm with a motor unit allows steady orbital rotation

Computerized special work station for intra-operative visualization

Imaging starts with rotation of 190° around the object to be studied

Inatraoperative 3D Imaging with Mobile Isocentric C-Arm

Siemens ARCADIS IsoC-3D

Page 100: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

During this movement, a set of 2D projections in fixed angular steps is recorded in normal or HD quality

DeviceInatraoperative 3D Imaging with Mobile Isocentric C-Arm

Siemens ARCADIS IsoC-3D

Page 101: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

During this movement, a set of 2D projections in fixed angular steps is recorded in normal or HD quality

DeviceInatraoperative 3D Imaging with Mobile Isocentric C-Arm

Siemens ARCADIS IsoC-3D

Page 102: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

During this movement, a set of 2D projections in fixed angular steps is recorded in normal or HD quality

DeviceInatraoperative 3D Imaging with Mobile Isocentric C-Arm

Siemens ARCADIS IsoC-3D

Page 103: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

Navigation Unit

Siremobil Iso-C-3D

Navi with IsoC-3D

Page 104: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

Carbon/ARCADIS/BrainLab

Page 105: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

Carbon/ARCADIS/BrainLab

Page 106: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

ARCADIS/BrainLab

Page 107: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

ARCADIS/BrainLab

Monitor

Page 108: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

59y, female, MVA

Monitor

Page 109: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

C-arm setup

MMoMooMMoMMMMM niniiiinnn tototootoooooooot rrrrrrrrr

Page 110: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

Arcadis ISO-C 3D

MMMoMoMoooMoMooooMMoooMMoMooMoooMMoooooMMoooonnniniiiiiiiiniinin ttotttttttt rrrrr

Page 111: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

Legs’ rotation

MMMMMMMMMMoMoMoMMMMoooMooMoMoMMMoMoMoMMM ininninnininniininnnin totootoooottotoootottoottoootoootoorrrrrrrrrrrrr

Page 112: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

“High Tech” - reduction tricks

Page 113: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

PIB removal

MoMoMoMoooMMoMoMMMMoooMMMoooMoooonnnninininnnnnniinnnnnininnnnniinninnnininittoootootttoottoooottoototooottotoottoorrrrrrrrrrrr

Page 114: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

PS reduction

MMMMMoMoMoMoMMoniniinnininiin tottotoootttooooototooorrrrrrr

Page 115: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

TEN

MoMMMoMM ninnnin totototorr

Page 116: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

PS Plating

MMMMMMoMMMMMoMoMMMMMoooMMMMMMMMoooooMMMMMMMMoooooMMMMMooooMMMooooMoMMMMooo iiinninnnnnninnnnninnnnniinininnnnittttttttoooottoooootototooototototorrrrrrrrrrrrrrrr

Page 117: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

Navigaton markers

MMoMMooooMoM nniiinininn tottoooootoootoooot rrrrrrrr

Page 118: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

Infracamera

MMoMooooM nninin totooorrrr

Page 119: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

“Arcadischeck”

MoMoMoMMoMooMooMoniinninninininitotttotototototototototot rrrrrrrrrrrr

Page 120: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

“Pointer”

MMoMMMMMooooMoMoMoMoooooMoMMooooonnininnniinnnniinnnnninnnninnnnniinnnnnniitttototottotttototoototorrrrrrrr

Page 121: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

Planning (80/48 mm/10mm

MoMoMoMoMoMoMMoMoMoMMMMoMooonninininininniininniniitototototootoooooottttoooottoooottooottotorrrrrrrrrrrrrrrrrr

Page 122: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

Calibration

MoMMoo inininiitototot rrr

Page 123: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

K-wires/drill/tap

MMMoMooooMMooMoMooMoMMoMoMoMooMoooMMoooonnniinniniinnninininininnniittttotooottottooorrrrrrrr

Page 124: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

SI screw insertion

MMMMMMMMooMMMooMMoMMMooMoMMMoooMMoMMMMMMMooooMMoooonnniininnniniinnininnitottoooooooooottttoorrrrrrrrrr

Page 125: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

Arcadis check

MoMM ninnin totototorrrr

Page 126: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

59y, female, MVA

Page 127: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

Variations in sacral morphology

MoMoMoMoniiininittttotottorrrrr

Page 128: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

AH, 33é, nőbeteg, AO 41C3

Page 129: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

AH, 33é, nőbeteg, AO 41C3

Page 130: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Tibia plateu navi

Page 131: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Tibia plateu navi

Page 132: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

• 3D Virtual Planning with prediction of stability that will lead to improved patient care

• Biomechanical lab • Application fields

– Clinical practice

– Education – Research

Take home...

Page 133: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

Novel techniques

Feasible

Enables the surgeon:

to evaluate fracture type

to judge reduction & implant position

intra-operative validation

ittoooooorr

The use of intraoperative three-dimensional imaging (ISO-C-3D) in fixation of intraarticular fractures K Atesok, J Finkelstein, A Khoury, A Peyser, Y Weil… - Injury, 2007 - Elsevier

Page 134: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Monitor

Novel techniques

MMoMoMoMoMoMoMo inininininininittototototototorrrrrrrM it

Feasible

Enables the surgeon:

to evaluate fracture type

to judge reduction & implant position

intra-operative validation

More safe, (anatomical variations!)Computer-assisted trauma surgery K Atesok, EH Schemitsch - Journal of the American …, 2010 - Am Acad Ortho Surgeons

Page 135: Computer Assisted Image Processing and …Sheet „ 1993-94 Canada “With the development of of image control guidance systems, percutaneous fixation of the unstable posterior pelvic

Sheet

Take home…

Severeal new “toys” exsist

“High Tech” is a better chance

The surgeon has to be remain “the doctor”