+ All Categories
Home > Documents > Conceptual Plan - TLE Land O Lakes - Pasco County, FL

Conceptual Plan - TLE Land O Lakes - Pasco County, FL

Date post: 03-Dec-2021
Category:
Upload: others
View: 3 times
Download: 0 times
Share this document with a friend
9
PRE SCHOOL #3 110 PRE SCHOOL #2 112 TOILET 111 TOILET 115 TOILET 113 PRE SCHOOL #1 114 TODDLERS A 116 TOILET 117 TOILET 119 TODDLERS B 118 LOUNGE 122 LAUNDRY 121 PANTRY 120 ELEC 125 TOILET 124 INFANTS A 123 INFANTS B 126 MECH 128 TOILET 127 TWADDLERS 129 TOILET 131 TOILET 130 PRE-K-K 132 OFFICE 102 VESTIBULE 100 RECEPTION 101 CL. 103 ISO 104 CORRIDOR 133 PREPPERS A / MBB 105 PREPPERS B 109 TOILET 106 TOILET 108 TOILET 107 PROPOSED TRASH ENCLOSURE (REFER TO DETAILS 1,2,3/SP-102) NEW 1 STORY BUILDING 10,000 S.F. DAYCARE FACILITY 40 PARKING SPACES Academy of Early Education PROPERTY LINE (TYP.) 6' WHITE PVC FENCE & GATES (REFER TO SHEET A-151) MONUMENT SIGN SEE SHEET A-161 PLAYGROUND (REFER TO SHEETS A-151 & A-152) 5,076 S.F. PLAYGROUND 4' WHITE PVC FENCE & GATES (REFER TO SHEET A-151) ROAD D- PRIVATE ROAD ROAD A PRIVATE ROAD COVERED ENTRANCEWAY 5' CONCRETE SIDWALK ARCHITECTURAL SITE PLAN GENERAL NOTES: 1. THIS ARCHITECTURAL SITE PLAN IS NOT INTENDED FOR PLANNING OR ZONING REVIEW, AND IS PROVIDED FOR COORDINATION PURPOSES ONLY. ALL SITE DESIGN SHALL BE CONFIRMED WITH AND COMPLETED PER THE APPROVED CIVIL SITE DRAWINGS AS PREPARED BY: To Be Determined 2. THE G.C. SHALL BE SOLELY RESPONSIBLE FOR AND HAVE CONTROL OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES, COMPLIANCE WITH APPLICABLE ORDINANCES AND JURISDICTIONAL JOB SITE REQUIREMENTS, AND FOR COORDINATING ALL PORTIONS OF THE PHASED WORK UNDER THE CONTRACT UNLESS OTHER SPECIFIC INSTRUCTIONS CONCERNING THESE MATTERS HAVE BEEN PROVIDED THROUGH THE DEVELOPER. 3. REFER TO THE CIVIL DRAWINGS FOR ALL SITE DIMENSIONS, GRADING AND EROSION CONTROL, UTILITY INFORMATION, LANDSCAPE AND IRRIGATION DESIGN AND ALL OTHER REQUIRED SITE RELATED IMPROVEMENTS. 4. PRIOR TO PROCEEDING WITH ROUGH GRADING, THE G.C. SHALL COORDINATE CIVIL GRADES WITH ELEVATIONS SPECIFIED AS PART OF THE ARCHITECTURAL SCOPE OF WORK (INCLUDING, BUT NOT LIMITED TO COMPARISON OF TOP OF FINISH GRADES AT PERIMETER OF BUILDING, FLAT WORK AND ADJOINING SITE AREAS). ALL QUESTIONS SHALL BE SUBMITTED IN WRITING TO THE CIVIL ENGINEER AND ARCHITECT PRIOR TO START OF WORK. 5. THE G.C. SHALL ROUGH GRADE AND RE-COMPACT BUILDING PADS PER THE SOILS REPORT AS PART OF THE SITE SCOPE OF WORK. 6. ALL GRADING AND CONCRETE PAVING SHALL SLOPE AWAY FROM THE BUILDING. CONTACT THE DEVELOPER, ARCHITECT AND CIVIL ENGINEER IN WRITING REGARDING ANY AREAS THAT CANNOT SLOPE AWAY DUE TO EXISTING CONDITIONS. 7. THE G.C. SHALL VERIFY ALL SITE DIMENSIONS TO APPLICABLE BOUNDARIES AND SETBACK INFORMATION WITH PARCEL MAP ALTA SURVEY OF RECORD AND NOTIFY OWNER, ARCHITECT, AND CIVIL ENGINEER IN WRITING OF ANY QUESTIONS IN THIS REGARD. 8. THE G.C. SHALL COORDINATE ALL SITE UTILITY RUNS WITH THE APPROPRIATE UTILITY COMPANIES AND PER THE APPROVED SITE PLANS. UTILITY RUNS SHALL BE STUBBED 5'-0" FROM THE BUILDING PERIMETER AT THE LOCATION INDICATED IN THE APPROVED M.E.P. DRAWINGS. 9. THE G.C. SHALL PROTECT EXISTING CONDITIONS TO REMAIN FROM DAMAGE. DAMAGED ITEMS SHALL BE REPLACED, REPAIRED, OR RESTORED BY THE G.C. IF, IN THE OPINION OF THE G.C., EXISTING CONDITIONS TO REMAIN WILL BE DAMAGED OR REQUIRE REMOVAL, THE GENERAL CONTRACTOR SHALL IDENTIFY THESE TO THE DEVELOPER PRIOR TO PROCEEDING WITH REMOVAL. KEY PLAN scale: 1"=20'-0" 1 FOR ANY SITE DATA PURPOSES ONLY. REFER TO CIVIL DRAWINGS THIS SITE KEY PLAN IS FOR COORDINATION P:\19047_TLE LAND O LAKES\DRAWINGS\99_TLE_LANDOLAKES_ARCH\SP-101.DWG KELSI PLOTTED: 12/27/2019 1. CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING THE CONTRACTOR'S BEST SKILL AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE AND HAVE CONTROL OVER CONSTRUCTION MEANS, METHODS TECHNIQUES, SEQUENCE, AND JOB SITE SAFETY 2. GC MUST PROVIDE & INSTALL ALL PRODUCTS PER PLANS. ONLY SUBSTITUTED PRODUCTS NEED TO BE SUBMITTED TO THE ARCHITECT FOR APPROVAL. UNAPPROVED SUBSTITUTIONS WILL BE REPLACED AT THE EXPENSE OF THE GC. 3. VERBAL REPRESENTATION HAS NO VALUE AND ALL REQUESTS TO CHANGE ANY PRODUCTS OR SPECIFICATIONS PER PLANS, MUST BE SUBMITTED IN WRITING TO THE ARCHITECT & TLE FOR APPROVAL. 2019.Q1.01 GEN PROTOTYPE NO. DATE DESCRIPTION INT. REVISION NO. DATE DESCRIPTION INT. ISSUE Drawing Number: Drawing Name: Scale: AS NOTED Project Number: 19047 Drawn By: Approved By: --- ACADEMY OF EARLY EDUCATION PROFESSIONAL CERTIFICATION NAME OF LICENSEE: STEVEN VINCI LICENSE NUMBER: AR0017036 EXPIRATION DATE: 2/28/21 FL-564 & BALLENTRAE BLVD. AT LAND O' LAKES PASCO COUNTY, FLORIDA 6699 13th Avenue North, Suite 4A St. Petersburg, FL 33710 (727) 381-5220 (727) 381-0052 fax Conceptual Site Plan 1 10/28/19 Schematic Design 2 12/26/19 NORTH ARCHITECTURAL SITE PLAN SP-101 SV
Transcript
Page 1: Conceptual Plan - TLE Land O Lakes - Pasco County, FL

PR

E S

CH

OO

L #

3

110

PR

E S

CH

OO

L #

2

112

TO

ILE

T

111

TO

ILE

T

115

TO

ILE

T

113

PR

E S

CH

OO

L #

1

114

TO

DD

LE

RS

A

116

TO

ILE

T

117

TO

ILE

T

119

TO

DD

LE

RS

B

118

LO

UN

GE

122

LA

UN

DR

Y

121

PA

NT

RY

120

ELE

C

125

TO

ILE

T

124

INF

AN

TS

A

123

INF

AN

TS

B

126

ME

CH

128

TO

ILE

T

127

TW

AD

DLE

RS

129

TO

ILE

T

131

TO

ILE

T

130

PR

E-K

-K

132

OF

FIC

E

102

VE

ST

IBU

LE

100

RE

CE

PT

ION

101

CL.

103

ISO

104

CO

RR

IDO

R

133

PR

EP

PE

RS

A / M

BB

105

PR

EP

PE

RS

B

109

TO

ILE

T

106

TO

ILE

T

108

TO

ILE

T

107

PROPOSED TRASH ENCLOSURE(REFER TO DETAILS 1,2,3/SP-102)

NEW 1 STORY BUILDING

10,000 S.F. DAYCARE FACILITY

40 PARKING SPACES

Academy of Early Education

PROPERTY LINE(TYP.)

6' WHITE PVC FENCE &GATES (REFER TO SHEETA-151)

MONUMENT SIGN SEESHEET A-161

PLAYGROUND(REFER TO SHEETSA-151 & A-152)

5,076 S.F.

PLAYGROUND

4' WHITE PVC FENCE &GATES (REFER TO SHEETA-151)

ROAD D- PRIVATE ROAD

ROAD APRIVATE ROAD

COVERED ENTRANCEWAY

5' CONCRETE SIDWALK

ARCHITECTURAL SITE PLAN GENERAL NOTES:

1. THIS ARCHITECTURAL SITE PLAN IS NOT INTENDED FOR

PLANNING OR ZONING REVIEW, AND IS PROVIDED FOR

COORDINATION PURPOSES ONLY. ALL SITE DESIGN SHALL BE

CONFIRMED WITH AND COMPLETED PER THE APPROVED CIVIL

SITE DRAWINGS AS PREPARED BY:

To Be Determined

2. THE G.C. SHALL BE SOLELY RESPONSIBLE FOR AND HAVE

CONTROL OVER CONSTRUCTION MEANS, METHODS,

TECHNIQUES, PROCEDURES, COMPLIANCE WITH APPLICABLE

ORDINANCES AND JURISDICTIONAL JOB SITE REQUIREMENTS,

AND FOR COORDINATING ALL PORTIONS OF THE PHASED WORK

UNDER THE CONTRACT UNLESS OTHER SPECIFIC INSTRUCTIONS

CONCERNING THESE MATTERS HAVE BEEN PROVIDED THROUGH

THE DEVELOPER.

3. REFER TO THE CIVIL DRAWINGS FOR ALL SITE DIMENSIONS,

GRADING AND EROSION CONTROL, UTILITY INFORMATION,

LANDSCAPE AND IRRIGATION DESIGN AND ALL OTHER REQUIRED

SITE RELATED IMPROVEMENTS.

4. PRIOR TO PROCEEDING WITH ROUGH GRADING, THE G.C. SHALL

COORDINATE CIVIL GRADES WITH ELEVATIONS SPECIFIED AS

PART OF THE ARCHITECTURAL SCOPE OF WORK (INCLUDING,

BUT NOT LIMITED TO COMPARISON OF TOP OF FINISH GRADES

AT PERIMETER OF BUILDING, FLAT WORK AND ADJOINING SITE

AREAS). ALL QUESTIONS SHALL BE SUBMITTED IN WRITING TO

THE CIVIL ENGINEER AND ARCHITECT PRIOR TO START OF WORK.

5. THE G.C. SHALL ROUGH GRADE AND RE-COMPACT BUILDING

PADS PER THE SOILS REPORT AS PART OF THE SITE SCOPE OF

WORK.

6. ALL GRADING AND CONCRETE PAVING SHALL SLOPE AWAY FROM

THE BUILDING. CONTACT THE DEVELOPER, ARCHITECT AND CIVIL

ENGINEER IN WRITING REGARDING ANY AREAS THAT CANNOT

SLOPE AWAY DUE TO EXISTING CONDITIONS.

7. THE G.C. SHALL VERIFY ALL SITE DIMENSIONS TO APPLICABLE

BOUNDARIES AND SETBACK INFORMATION WITH PARCEL MAP

ALTA SURVEY OF RECORD AND NOTIFY OWNER, ARCHITECT, AND

CIVIL ENGINEER IN WRITING OF ANY QUESTIONS IN THIS REGARD.

8. THE G.C. SHALL COORDINATE ALL SITE UTILITY RUNS WITH THE

APPROPRIATE UTILITY COMPANIES AND PER THE APPROVED

SITE PLANS. UTILITY RUNS SHALL BE STUBBED 5'-0" FROM THE

BUILDING PERIMETER AT THE LOCATION INDICATED IN THE

APPROVED M.E.P. DRAWINGS.

9. THE G.C. SHALL PROTECT EXISTING CONDITIONS TO REMAIN

FROM DAMAGE. DAMAGED ITEMS SHALL BE REPLACED,

REPAIRED, OR RESTORED BY THE G.C. IF, IN THE OPINION OF

THE G.C., EXISTING CONDITIONS TO REMAIN WILL BE DAMAGED

OR REQUIRE REMOVAL, THE GENERAL CONTRACTOR SHALL

IDENTIFY THESE TO THE DEVELOPER PRIOR TO PROCEEDING

WITH REMOVAL.

KEY PLANscale: 1"=20'-0"1FOR ANY SITE DATAPURPOSES ONLY. REFER TO CIVIL DRAWINGSTHIS SITE KEY PLAN IS FOR COORDINATION

P:\1

90

47

_T

LE

L

AN

D O

L

AK

ES

\D

RA

WIN

GS

\9

9_

TL

E_

LA

ND

OL

AK

ES

_A

RC

H\S

P-1

01

.D

WG

K

EL

SI P

LO

TT

ED

: 1

2/2

7/2

01

9

1. CONTRACTOR SHALL SUPERVISE AND DIRECT

THE WORK USING THE CONTRACTOR'S BEST

SKILL AND ATTENTION. THE CONTRACTOR SHALL

BE SOLELY RESPONSIBLE AND HAVE CONTROL

OVER CONSTRUCTION MEANS, METHODS

TECHNIQUES, SEQUENCE, AND JOB SITE SAFETY

2. GC MUST PROVIDE & INSTALL ALL PRODUCTS

PER PLANS. ONLY SUBSTITUTED PRODUCTS

NEED TO BE SUBMITTED TO THE ARCHITECT FOR

APPROVAL. UNAPPROVED SUBSTITUTIONS WILL

BE REPLACED AT THE EXPENSE OF THE GC.

3. VERBAL REPRESENTATION HAS NO VALUE AND

ALL REQUESTS TO CHANGE ANY PRODUCTS OR

SPECIFICATIONS PER PLANS, MUST BE

SUBMITTED IN WRITING TO THE ARCHITECT & TLE

FOR APPROVAL.

2019.Q1.01 GEN PROTOTYPE

NO. DATE DESCRIPTION INT.

REVISION

NO. DATE DESCRIPTION INT.

ISSUE

Drawing Number:

Drawing Name:

Scale:

AS NOTED

Project Number:

19047

Drawn By:

Approved By:

---

AC

AD

EM

Y O

F E

AR

LY

E

DU

CA

TIO

N

PROFESSIONAL CERTIFICATION

NAME OF LICENSEE: STEVEN VINCI

LICENSE NUMBER: AR0017036

EXPIRATION DATE: 2/28/21

FL

-564 &

B

AL

LE

NT

RA

E B

LV

D. A

T

LA

ND

O

' L

AK

ES

PA

SC

O C

OU

NT

Y, F

LO

RID

A

6699

13t

h A

venu

e N

orth

, Sui

te 4

AS

t. P

eter

sbur

g, F

L 33

710

(727

) 38

1-52

20(7

27)

381-

0052

fax

Conceptual Site Plan1 10/28/19

Schematic Design2 12/26/19

NORTH

ARCHITECTURAL

SITE PLAN

SP-101

SV

AutoCAD SHX Text
P
AutoCAD SHX Text
P
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
Open
AutoCAD SHX Text
W
AutoCAD SHX Text
D
AutoCAD SHX Text
B
AutoCAD SHX Text
u
AutoCAD SHX Text
b
AutoCAD SHX Text
b
AutoCAD SHX Text
l
AutoCAD SHX Text
e
AutoCAD SHX Text
s
AutoCAD SHX Text
B
AutoCAD SHX Text
u
AutoCAD SHX Text
b
AutoCAD SHX Text
b
AutoCAD SHX Text
l
AutoCAD SHX Text
e
AutoCAD SHX Text
s
Page 2: Conceptual Plan - TLE Land O Lakes - Pasco County, FL

PRE SCHOOL #3

110

PRE SCHOOL #2

112

TOILET

111

TOILET

115

TOILET

113

PRE SCHOOL #1

114

TODDLERS A

116

TOILET

117

TOILET

119

TODDLERS B

118

LOUNGE

122

LAUNDRY

121

PANTRY

120

ELEC

125

TOILET

124

INFANTS A

123

INFANTS B

126

MECH

128

TOILET

127

TWADDLERS

129

TOILET

131

TOILET

130

PRE-K-K

132

OFFICE

102

VESTIBULE

100

RECEPTION

101

CL.

103

ISO

104

CORRIDOR

133

PREPPERS A / MBB

105

PREPPERS B

109

TOILET

106

TOILET

108

TOILET

107

REC-1

FE-1

5432

B

1 6

A

C

ISO-1

CL-1

PKK-1 PKK-2

3 3 3 3

33333

OF-1

3

VES-1

A A

C C C C CC C C C C C

C

B B

PS-3-2

CO-1-1

FE-1

3

A051

3

A051

4

A051

2

A051

1

PS-3-1TO-A-1 TO-B-1

IN-A-1

IN-A-2

IN-B-2

IN-B-1

MEC-1

TW-1

TW-2

PEPB-1PEPB-2

TO-B-2TO-A-2

PS-2-1 PS-2-2 PS-1-1 PS-1-2

VES-2

ELC-1

PAN-1

SL-1

LAN-1

PS-3-3

PS-2-3

PS-1-3

TO-A-3

TO-B-3

ST-1

TW-3

PEPB-3

IN-A-3

IN-B-3

CO-2

ST-2

FE-1

FE-2

3

3

3

M

PKK-3

A061

1

A061

2

B B

B B

B B

PEPA-1PEPA-2

PEPA-3

FE-2

8

13B

15

8

7

5

8

10

6

8

4

11

18

17

1

16

4

16

12

4

9

14

88

8

12

8

12

3

1

8

13A

2

1

M

M

M

MM

M

M

M

M

M

M

2

TYP.

A-081

7

GROSS AREA 10,000 S.F.

* CALCULATED LESS BUILT-IN ITEMS

18-24 MO.1/62121/35458TODDLERS B

1/4

PRE-SCHOOL #1 3-4 YRS.

PRE-SCHOOL #2 1/35

4-5 YRS.

1/35540

525

525 15 1

S.F.

NET*

6125 6651 -- 175 18 --

2

--TOTALS

24-30 MO.1/111/35TWADDLERS

5-6 YRS.PRE K-K 1/25

GROUPRATIOTEACHERSCHILDRENPER S.F.S.F.

AGETEACHER# OFRATIO CHILDACTUALROOM

LICENSING CALCULATIONS

420

15 1

1/35875 25 1

The Learning Experience, Pasco County, Florida

375INFANT A 1/46 WK-12 MO.

280 8 2

1/15

1/15

813

911

6362

STATE

REQUIRED

S.F.( 35 S.F.

PER CHILD)

527

775

420

880

337

# OF

PLAY AREA 5,076 S.F.

1201/35PRE-SCHOOL #3

3-5 YRS.

700 711700 1/20

1/4INFANT B 1/412 MO.-18 MO.

8 2

18-24 MO.1/62121/35458TODDLERS A 420 420

1/35

1/35

375280 337

220700 30-36 MO.1/111/35PREPPERS B 712701

540527

2 30-36 MO.1/111/35PREPPERS A / MBB 758738700

700

20

20

#

FE-X

FE-X

101

KEYNOTE NUMBER;

ROOM NUMBER

DOOR NUMBER;

REFER TO DRAWINGS A-121 AND A-122 FOR DOOR SCHEDULE,

DOOR HARDWARE SCHEDULE, AND DETAILS

WINDOW STYLE;

REFER TO DRAWING A-123 FOR WINDOW SCHEDULE,

ELEVATIONS AND DETAILS

NUMBER OF BIN CUBBIES (BC) OR BATH SHELVES (BS); REFER

TO DRAWINGS A-131; BIN CUBBIES SHOWN FOR AREA

CALCULATIONS ONLY, AND TO BE PROVIDED BY GC. EXACT

LOCATIONS TO BE COORDINATED WITH TLE.

DRINKING FOUNTAIN;

REFER TO DRAWING A-111 FOR INSTALLATION DETAILS AND

P-100 FOR SPECIFICATIONS

BLIND SPOT MIRROR, KLEAR-VU BY BROSSARD #P-180;

18" DOME STYLE CONVEX MIRRORS FOR BLIND SPOTS IN

ROOMS TO BE MOUNTED @ 6" BELOW FINISH CEILING. EXACT

NUMBER AND LOCATIONS TO BE COORDINATED WITH TLE.

CEILING MOUNTED CAMERA;

MOUNTED CAMERAS TO BE INSTALLED TO ENSURE ADEQUATE

COVERAGE THROUGHOUT, INCLUDING AT THE EXTERIOR FOR

THE PLAYGROUND. EXACT QUANTITY AND LOCATIONS TO BE

COORDINATED WITH TLE. REFER TO SPECIFICATIONS FOR

FURTHER INFORMATION.

FIRE EXTINGUISHER; WALL HUNG, BRACKET

FE-1 = 5lb B:C, FE-2 = 10lb A:B:C (1 PER 3,000 SQ.FT.)

MANUFACTURER: JL COSMIC

BRACKET COLOR: WHITE

INSPECTION TAGS REQUIRED FOR ALL FIRE EXTINGUISHERS

FIRE EXTINGUISHER; WALL HUNG, SEMI-RECESSED CABINET

FE-1 = 5lb B:C, FE-2 = 10lb A:B:C (1 PER 3,000 SQ.FT.)

MANUFACTURER: JL COSMIC

MODEL: 1017F10 WITH ROUNDED CORNERS

CABINET COLOR: WHITE

INSPECTION TAGS REQUIRED FOR ALL FIRE EXTINGUISHERS

LAUNDRY APPLIANCES (SIDE-BY-SIDE; TYPICAL)

WASHER MODEL: G.E. GTW485ASJWS (ENERGY STAR)

DRYER MODEL: WHIRLPOOL WED95HEDW (ENERGY STAR)

LAUNDRY APPLIANCES (STACKABLE; ONLY IF SHOWN ON PLAN)

WASHER MODEL: G.E. GFWN1600J (ENERGY STAR)

DRYER MODEL: G.E. GFDN160EJ (ENERGY STAR)

M

D

W

D

W

CONSTRUCTION PLAN LEGEND:

A

X

BC#

BS#

1. REFER TO STRUCTURAL DRAWINGS FOR ALL STRUCTURAL

INFORMATION.

2. ALL ANGLED WALLS, IF SHOWN ON FLOOR PLAN, SHALL BE

45° UNLESS NOTED OTHERWISE.

3. ALL OUTSIDE CORNERS WITHIN ALL ROOMS SHALL HAVE

3

4

"

RADIUS PVC CORNER BEADS AT ALL CORNERS AND

GYPSUM BOARD WINDOW RETURNS - SEE DETAILS 2 & 3

/A-091

4. FOR PARTITION DESIGNATIONS REFER TO DRAWING A-012

AND DRAWING A-091 FOR PARTITION TYPE DETAILS.

5. PREPPERS A (MBB) ENLARGED PLANS - SEE SHEET A-101

6. REFER TO DRAWING A-111 FOR ENLARGED TOILET ROOM

PLANS AND DRINKING FOUNTAIN DETAILS. REFER TO P-100

FOR SPECIFICATIONS.

7. REFER TO DRAWING A-043 FOR FURNITURE AND

MILLWORK PLANS.

8. ALL MILLWORK ELEVATIONS & DETAILS - SEE SHEET A-131

& A-132. BOOKSHELVES ARE NOT SHOWN IN THE

CONSTRUCTION PLANS. COORDINATE WITH TLE FOR

EXACT LOCATION(S).

9. FOR PANTRY SEE SHEET A-133

10. FOR RECEPTION AREA ENLARGED PLANS - SEE SHEET

A-134

11. OUTSIDE PLAYGROUND ENLARGED PLANS - SEE SHEETS

A-151, A-152 AND A-153

12. REFER TO DRAWING T-200 FOR LIST OF REQUIRED AND

APPROVED VENDORS.

13. REFER TO SPECIFICATIONS DRAWINGS FOR INSTALLATION

INFORMATION.

14. REFER TO SPECIFICATIONS DRAWINGS FOR ALL

APPLIANCE, LOW VOLTAGE COMPONENT, AND

PLAYGROUND EQUIPMENT SPECIFICATIONS. LOW

VOLTAGE COMPONENT LOCATIONS AND QUANTITIES

SHALL BE COORDINATED WITH "THE LEARNING

EXPERIENCE."

15. THE ENTIRE BUILDING SHALL BE THOROUGHLY CLEANED,

INCLUDING WAXING & POLISHING, AT THE COMPLETION OF

CONSTRUCTION.

16. DRYWALL CONTROL JOINTS TO BE FAS-093X BY CLARK

DIETRICH (OR APPROVED EQUAL) AND SHALL BE ALIGNED

WITH DOOR OR WINDOW JAMB (LEFT OR RIGHT) AT

MAXIMUM INTERVALS OF 30'-0". ALSO REFER TO DETAIL 2

ON A-042.

CONSTRUCTION PLAN GENERAL NOTES:

CONSTRUCTION PLAN KEYNOTES:

CONCRETE SIDEWALK. REFER TO APPROVED SITE PLANS FOR FINISHES AND DETAILS. ENSURE SIDEWALKS ARE CLEAR OF OBSTRUCTIONS.

PROVIDE FENCING AROUND ANY POTENTIAL SAFETY HAZARDS TO PREVENT ACCESS BY CHILDREN

PROVIDE CONCRETE PAD AND CANVAS AWNING. PROVIDE PICNIC TABLES AS SHOWN. REFER TO DRAWINGS A-151 & A-152 FOR ADDITIONAL

INFORMATION

4 FT. TALL LATTICE STYLE FENCE AND GATE. SEE A-151 FOR MORE INFORMATION

PITTCON 6" RADIUS SO-LRT OUTSIDE CORNER WITH TANGENT FINS BY SOFTFORMS. REFER TO DETAIL 4 ON DRAWING A-091

BENCH SEAT - SEE DETAIL 3/A-134

LCD TV/DVD TO BE MOUNTED at 7'-8" A.F.F. WITH EASYMOUNT FULLY ADJUSTABLE, SWING-OUT BRACKET FASTENED TO STUDS. PROVIDE 2x10

BLOCKING (32" WIDE) BEHIND TV.- FLUSH WITH BOTTOM OF OUTLET & CENTERED ON OUTLET. LOCATION TO BE COORDINATED WITH "THE LEARNING

EXPERIENCE." REFER TO DRAWING T-300 FOR SPECIFICATIONS

PROVIDE MONITOR TO BE MOUNTED ON (2) WALL-MOUNTED BRACKETS WITH 2X10" BLOCKING (32" WIDE)- FLUSH WITH BOTTOM OF OUTLET AND

CENTERED ON OUTLET. REFER TO DETAIL 2 ON DRAWING A-134

SMART BOARD TO BE INSTALLED BY TENANT- REFER TO DETAILS ON DRAWING A-091

INSTALL (1) WIRE SHELF 16" DEEP MOUNTED AT 6'-0" A.F.F.; FASTENED DIRECTLY TO STUDS. PROVIDE 2x10 BLOCKING AS REQUIRED. LAUNDRY:

WALL TO WALL SHELF

PROVIDE (5) 16" DEEP WIRE SHELVES IN THE CLOSET, WALL TO WALL. FIRST SHELF AT 20" A.F.F., THEN 34", 48", 62", & 76" A.F.F. (5 SHELVES TOTAL).

PROVIDE 2x10" BLOCKING AS REQUIRED.

ROOF ACCESS LADDER - SEE ELEVATIONS AND ROOF PLAN.

DOWNSPOUT - CONNECT TO STORM SEWER

DRINKING FOUNTAIN - A = HIGH, B = LOW

WATER HEATER SUSPENDED FROM STRUCTURE ABOVE; REF PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION

BATH SHELVES; REFER TO DETAIL 1/A-131

INSTALL INFANT CHAIR RAIL AT 36" AFF OVER CARPETED SECTION OF ROOM IN INFANT ROOM ONLY. PAINTED "W" PER DRAWINGS A-042.

FIRE RISER

ELECTRICAL METER AND DISCONNECT

CONSTRUCTION

PLAN

A-011

P:\1

90

47

_T

LE

L

AN

D O

L

AK

ES

\D

RA

WIN

GS

\9

9_

TL

E_

LA

ND

OL

AK

ES

_A

RC

H\2

01

9.Q

1.0

1 G

EN

P

RO

TO

TY

PE

-A

-0

11

.D

WG

K

EL

SI P

LO

TT

ED

: 1

2/2

7/2

01

9

1. CONTRACTOR SHALL SUPERVISE AND DIRECT

THE WORK USING THE CONTRACTOR'S BEST

SKILL AND ATTENTION. THE CONTRACTOR SHALL

BE SOLELY RESPONSIBLE AND HAVE CONTROL

OVER CONSTRUCTION MEANS, METHODS

TECHNIQUES, SEQUENCE, AND JOB SITE SAFETY

2. GC MUST PROVIDE & INSTALL ALL PRODUCTS

PER PLANS. ONLY SUBSTITUTED PRODUCTS

NEED TO BE SUBMITTED TO THE ARCHITECT FOR

APPROVAL. UNAPPROVED SUBSTITUTIONS WILL

BE REPLACED AT THE EXPENSE OF THE GC.

3. VERBAL REPRESENTATION HAS NO VALUE AND

ALL REQUESTS TO CHANGE ANY PRODUCTS OR

SPECIFICATIONS PER PLANS, MUST BE

SUBMITTED IN WRITING TO THE ARCHITECT & TLE

FOR APPROVAL.

2019.Q1.01 GEN PROTOTYPE

NO. DATE DESCRIPTION INT.

REVISION

NO. DATE DESCRIPTION INT.

ISSUE

Drawing Number:

Drawing Name:

Scale:

AS NOTED

Project Number:

19047

Drawn By:

Approved By:

---

AC

AD

EM

Y O

F E

AR

LY

E

DU

CA

TIO

N

PROFESSIONAL CERTIFICATION

NAME OF LICENSEE: STEVEN VINCI

LICENSE NUMBER: AR0017036

EXPIRATION DATE: 2/28/21

FL

-564 &

B

AL

LE

NT

RA

E B

LV

D. A

T

LA

ND

O

' L

AK

ES

PA

SC

O C

OU

NT

Y, F

LO

RID

A

6699

13t

h A

venu

e N

orth

, Sui

te 4

AS

t. P

eter

sbur

g, F

L 33

710

(727

) 38

1-52

20(7

27)

381-

0052

fax

Conceptual Site Plan1 10/28/19

Schematic Design2 12/26/19

NORTH SCALE:

1

CONSTRUCTION PLAN

1/8"=1'-0"

SV | KT

AutoCAD SHX Text
P
AutoCAD SHX Text
P
AutoCAD SHX Text
W
AutoCAD SHX Text
D
AutoCAD SHX Text
K-12100-C
AutoCAD SHX Text
FREEWILL
AutoCAD SHX Text
SHOWERS
AutoCAD SHX Text
ACRYLIC
AutoCAD SHX Text
CRIB
AutoCAD SHX Text
CRIB
AutoCAD SHX Text
CRIB
AutoCAD SHX Text
CRIB
AutoCAD SHX Text
CRIB
AutoCAD SHX Text
CRIB
AutoCAD SHX Text
CRIB
AutoCAD SHX Text
CRIB
AutoCAD SHX Text
CRIB
AutoCAD SHX Text
CRIB
AutoCAD SHX Text
CRIB
AutoCAD SHX Text
CRIB
AutoCAD SHX Text
CRIB
AutoCAD SHX Text
CRIB
AutoCAD SHX Text
CRIB
AutoCAD SHX Text
CRIB
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
8
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
B
AutoCAD SHX Text
u
AutoCAD SHX Text
b
AutoCAD SHX Text
b
AutoCAD SHX Text
l
AutoCAD SHX Text
e
AutoCAD SHX Text
s
Page 3: Conceptual Plan - TLE Land O Lakes - Pasco County, FL

PRE SCHOOL #3

110

PRE SCHOOL #2

112

TOILET

111

TOILET

115

TOILET

113

PRE SCHOOL #1

114

TODDLERS A

116

TOILET

117

TOILET

119

TODDLERS B

118

LOUNGE

122

LAUNDRY

121

PANTRY

120

ELEC

125

TOILET

124

INFANTS A

123

INFANTS B

126

MECH

128

TOILET

127

TWADDLERS

129

TOILET

131

TOILET

130

PRE-K-K

132

OFFICE

102

VESTIBULE

100

RECEPTION

101

CL.

103

ISO

104

CORRIDOR

133

PREPPERS A / MBB

105

PREPPERS B

109

TOILET

106

TOILET

108

TOILET

107

5432

26'-8"31'-0"29'-3"26'-0"31'-9"

B

144'-8"

38

'-9

"3

0'-3

"

1 6

A

C

69

'-0

"

35

'-0

"3

4'-0

"

69

'-0

"

8"

2'-8

"

8"

6'-8"6'-0"16'-4"10'-4"12'-0"5'-8"11'-4"5'-8"11'-4"6'-0"16'-8"6'-0"15'-4"6'-0"9'-4"

14

'-2

"7

'-0

"7

'-6

"1

0'-2

"1

0'-0

"2

0'-2

"

2'-8

"

9'-4"

7'-4"23'-4"7'-4"16'-4"8'-8"8'-8"16'-4"7'-4"23'-4"7'-4"9'-4"

6'-0

"

16'-3"

19'-4

1

2

"

2'-11"

24'-10

1

2

"

30'-7" 4'-6"

3'-9

"5

'-0

"

8'-2

1 2

"

10

'-7

1 2

"

14

'-1

"

13

'-1

0"

8'-8

1 2

"

10'-3"

6'-11"

25'-11"

8'-0

"

8'-8

1 2

"

15

'-5

"

6'-5

"

2'-9"

4'-1

"

14'-10

1

2

"

11'-6"

8"

2'-8"

8"

20'-8"3'-4"2'-8" 20'-8" 3'-4"

72'-4" 72'-4"

6'-6" 3'-3" 3'-3" 16'-3" 3'-3"13'-8" 3'-3" 13'-8"

11'-6"

1'-8"

6'-5" 7'-9"

4'-4"

2'-2"

7'-1

1"

7'-1

0"

30

'-5

1 2

"

6'-0"

15'-8

1

2

"

5'-5

"5

'-0

"

8'-0

"

8'-8

1 2

"

6'-1

1"

10

'-0

"

4'-1

0"

8'-8

"

6'-5

"

4'-0

"

6'-1

1"

4'-0

"

6'-1

1"

4'-0

"

10

'-1

1"

4'-0

"

7'-5

"

10

'-1

1"

4'-0

"

4'-0

"

10

'-0

"4

'-0

"

10

'-0

"4

'-0

"

A-061

2

A-061

1

17

'-8

"

16

'-1

0

1 2

"

7'-1

1"

7'-1

1"

6'-9

1 2

"

1

2'-4"

3'-4"

2'-4"

3'-4"

3'-4

"

16

'-8

"

44

4

4

4

4

4

4

4

4

44

4

4

4

2

2

1

1

2

2

12

2

222

2

2

3

3

3

3

3

3

3

3

1

1

1

1

3

22

2

2

2

2

2

2

2

2

2

2

2

2

1

2

2

1

2

2

2

2

1

2

2

2

2

2

3

2

3

2

3

2

1

2

1

1

1

1

11

1

20

'-3

"4

'-0

"

1

8'-8

1 2

"

3'-8

"3

'-8

"

1

1

1

1

1

1

1'-2"

TOTAL GROSS SQUARE FOOT =

10,000 SQUARE FEET

2'-3

"

9'-9" 3'-5"

TYP.

A-081

7

23'-6" 21'-0" 21'-0" 22'-9"56'-5"

9'-6

"

9'-6

"

NOTE: INSTALL DOOR FRAME SO

THAT HINGE SIDE OF DOOR OPENING

IS 4" FROM ADJACENT WALL, UNLESS

NOTED OTHERWISE.

NOTE: INSTALL DOOR FRAME SO

THAT HINGE SIDE OF DOOR

OPENING IS 6" FROM ADJACENT

WALL, UNLESS NOTED OTHERWISE.

NOTE: INTERIOR WINDOWS ADJACENT

TO DOORS SHALL BE INSTALLED SUCH

THAT A MINIMUM OF 1'-6" WALL SPACE

IS MAINTAINED BETWEEN THE DOOR

FRAME AND THE WINDOW FRAME,

UNLESS OTHERWISE NOTED ON THE

PLAN. INSTALLATION OF LIGHT SWITCH

BOX & TELEPHONE BOX REQUIRED.

LOCATIONS:

· ALL TOILET ROOMS

· RECEPTION

· OFFICE

· LAUNDRY

· JANITOR'S CLOSET

4"

6"

6"

1'-6"

U.N.O.

INTERIOR PARTITION

3

PLUMBING WALL

2

EXTERIOR WALL ASSEMBLY

(REF. WALL SECTIONS)

REFER TO A-091 FOR PARTITION DETAILS

4

PARTITION LEGEND:

FULL HEIGHT INTERIOR PARTITION

1

1. ALL DIMENSIONS SHOWN ARE MEASURED TO THE

CENTER LINE OF INTERIOR FRAMING OR EXTERIOR

FACE OF THE FOUNDATION WALL UNLESS NOTED

OTHERWISE.

2. ALL INTERIOR WALLS ARE 4.75" THICK UNLESS

OTHERWISE NOTED.

3. REFER TO DRAWING A-091 FOR ADDITIONAL PARTITION

TYPE INFORMATION.

4. REFER TO DRAWING A-011 FOR ADDITIONAL GENERAL

NOTES, KEY NOTES, AND SYMBOL LEGEND.

GENERAL NOTES:

1

DIMENSION OF BLOCKING AT SMART

BOARD. REFER TO DETAILS 1/A-082.

KEY NOTES:

NORTH

DIMENSION

PLAN

A-012

P:\1

90

47

_T

LE

L

AN

D O

L

AK

ES

\D

RA

WIN

GS

\9

9_

TL

E_

LA

ND

OL

AK

ES

_A

RC

H\2

01

9.Q

1.0

1 G

EN

P

RO

TO

TY

PE

-A

-0

12

.D

WG

K

EL

SI P

LO

TT

ED

: 1

2/2

7/2

01

9

1. CONTRACTOR SHALL SUPERVISE AND DIRECT

THE WORK USING THE CONTRACTOR'S BEST

SKILL AND ATTENTION. THE CONTRACTOR SHALL

BE SOLELY RESPONSIBLE AND HAVE CONTROL

OVER CONSTRUCTION MEANS, METHODS

TECHNIQUES, SEQUENCE, AND JOB SITE SAFETY

2. GC MUST PROVIDE & INSTALL ALL PRODUCTS

PER PLANS. ONLY SUBSTITUTED PRODUCTS

NEED TO BE SUBMITTED TO THE ARCHITECT FOR

APPROVAL. UNAPPROVED SUBSTITUTIONS WILL

BE REPLACED AT THE EXPENSE OF THE GC.

3. VERBAL REPRESENTATION HAS NO VALUE AND

ALL REQUESTS TO CHANGE ANY PRODUCTS OR

SPECIFICATIONS PER PLANS, MUST BE

SUBMITTED IN WRITING TO THE ARCHITECT & TLE

FOR APPROVAL.

2019.Q1.01 GEN PROTOTYPE

NO. DATE DESCRIPTION INT.

REVISION

NO. DATE DESCRIPTION INT.

ISSUE

Drawing Number:

Drawing Name:

Scale:

AS NOTED

Project Number:

19047

Drawn By:

Approved By:

---

AC

AD

EM

Y O

F E

AR

LY

E

DU

CA

TIO

N

PROFESSIONAL CERTIFICATION

NAME OF LICENSEE: STEVEN VINCI

LICENSE NUMBER: AR0017036

EXPIRATION DATE: 2/28/21

FL

-564 &

B

AL

LE

NT

RA

E B

LV

D. A

T

LA

ND

O

' L

AK

ES

PA

SC

O C

OU

NT

Y, F

LO

RID

A

6699

13t

h A

venu

e N

orth

, Sui

te 4

AS

t. P

eter

sbur

g, F

L 33

710

(727

) 38

1-52

20(7

27)

381-

0052

fax

Conceptual Site Plan1 10/28/19

Schematic Design2 12/26/19

SCALE:

1

DIMENSION PLAN

1/8"=1'-0"

SCALE:

2

TYP. HINGE SIDE DOOR TO WALL

NTS

SCALE:

3

ALT. HINGE SIDE DOOR TO WALL

NTS

SCALE:

4

CONSTRUCTION BETWEEN DOOR

& INTERIOR WINDOW

NTS

SV | KT

AutoCAD SHX Text
B
AutoCAD SHX Text
u
AutoCAD SHX Text
b
AutoCAD SHX Text
b
AutoCAD SHX Text
l
AutoCAD SHX Text
e
AutoCAD SHX Text
s
Page 4: Conceptual Plan - TLE Land O Lakes - Pasco County, FL

2'X4' ARMSTRONG 1729 FINE FISSURED, WHITE LAY IN ACOUSTIC

TILE WITH SQUARE LAY-IN JOINTS. PRELUDE 15/16" EXPOSED TEE

GRID OR EQUAL

2'X4' ARMSTRONG 2910 RANDOM FISSURED, WHITE LAY-IN

ACOUSTIC TILE WITH MYLAR FINISH AND SQUARE LAY-IN JOINTS.

PRELUDE 15/16" EXPOSED TEE GRID OR EQUAL

2'X2' ARMSTRONG 584, WHITE LAY-IN ACOUSTIC TILE WITH REVEAL

EDGE JOINTS. PRELUDE 15/16" EXPOSED TEE GRID OR EQUAL

GYPSUM BD. SOFFIT

2X4 LIGHT - 2'X4' RECESSED LED LIGHT FIXTURE. 'A3' TAG

INDICATES ALTERNATE LAMPING ONLY WHERE INDICATED. REFER

TO ELECTRICAL DRAWINGS FOR LIGHT FIXTURE SCHEDULE.

2X4 LIGHT - 2'X4' RECESSED LED EMERGENCY NIGHT LIGHT

FIXTURE WITH BATTERY BACK-UP. 'A3' TAG INDICATES ALTERNATE

LAMPING ONLY WHERE INDICATED. REFER TO ELECTRICAL

DRAWINGS FOR LIGHT FIXTURE SCHEDULE.

2X2 LIGHT - 2'X2' RECESSED LED LIGHT FIXTURE (REFER TO

ELECTRICAL DRAWINGS - LIGHT FIXTURE SCHEDULE).

2X2 LIGHT - 2'X2' RECESSED LED EMERGENCY NIGHT LIGHT

FIXTURE WITH BATTERY BACK-UP (REFER TO ELECTRICAL

DRAWINGS - LIGHT FIXTURE SCHEDULE).

LOGO SIGN - "THE LEARNING EXPERIENCE" ILLUMINATED SIGNAGE

MOUNTED ON CANOPY - SEE DRAWING A-161.

WB - WALL BRACKET - LED LIGHT FIXTURE (REFER TO ELECTRICAL

DRAWINGS - LIGHT FIXTURE SCHEDULE) MOUNTED @ +8'-6" AFF.

PROVIDE FIXTURE WITH PROTECTIVE WIRE CAGE.

RECESSED LED DOWN LIGHT AT UPPER LEVEL MAKE BELIEVE

BLVD. (REFER TO ELECTRICAL DRAWINGS - LIGHT FIXTURE

SCHEDULE)

RECESSED LED DOWN EMERGENCY NIGHT LIGHT FIXTURE WITH

BATTERY BACK-UP AT UPPER LEVEL MAKE BELIEVE BLVD. (REFER

TO ELECTRICAL DRAWINGS - LIGHT FIXTURE SCHEDULE)

RECESSED LED DOWN LIGHT. (REFER TO ELEC. DRAWINGS - LIGHT

FIXTURE SCHEDULE).

RECESSED LED DOWN EMERGENCY NIGHT LIGHT FIXTURE WITH

BATTERY BACK-UP. (REFER TO ELEC. DRAWINGS - LIGHT FIXTURE

SCHEDULE).

WALL MOUNTED SCONCE. MOUNT @42" A.F.F. SEE M.B.B. LOWER

LEVEL LIGHTING PLAN THIS PAGE.

RECESSED LED DOWN LIGHT (REFER TO ELECTRICAL DRAWINGS -

LIGHT FIXTURE SCHEDULE)

RECESSED EXTERIOR DOWN LIGHT (REFER TO ELECTRICAL

DRAWINGS - LIGHT FIXTURE SCHEDULE)

EXTERIOR WALL MOUNTED LED EXIT LIGHT FIXTURE WITH DUAL

EMERGENCY LAMPS. TO BE MOUNTED OVER THE MAIN ENTRANCE

@ 9'-6" A.F.F. AND ALL OTHER EXTERIOR DOORS @ 9'-0" A.F.F.

(REFER TO ELECTRICAL DRAWINGS - LIGHT FIXTURE SCHEDULE)

FIXTURE FINISH TO BE WHITE.

CEILING MOUNTED ILLUMINATED EXIT SIGN WITH BATTERY

BACK-UP. SHADING INDICATES ILLUMINATED FACE AND ARROW

INDICATES DIRECTION OF EGRESS. MOUNT ON UNDERSIDE OF

SOFFIT AS REQUIRED FOR INTENDED VISIBILITY

WB

#

#

REFLECTED CEILING - LEGEND:

PRE SCHOOL #3

110

PRE SCHOOL #2

112

TOILET

111

TOILET

115

TOILET

113

PRE SCHOOL #1

114

TODDLERS A

116

TOILET

117

TOILET

119

TODDLERS B

118

LOUNGE

122

LAUNDRY

121

PANTRY

120

ELEC

125

TOILET

124

INFANTS A

123

INFANTS B

126

MECH

128

TOILET

127

TWADDLERS

129

TOILET

131

TOILET

130

PRE-K-K

132

OFFICE

102

VESTIBULE

100

RECEPTION

101

CL.

103

ISO

104

CORRIDOR

133

PREPPERS A / MBB

105

PREPPERS B

109

TOILET

106

TOILET

108

TOILET

107

NL/

EM

NL/EM NL/EMNL/EM

NL/EM

NL/EM NL/EM

NL/EM

NL/

EM

NL/

EM

NL/

EM

NL/EM

NL/EM

NL/EM

NL/EM NL/EM NL/EM NL/EM

NL/EM

NL/EM

NL/EM

NL/EM

NL/EM

NL/EM

NL/EM

NL/EM

NL/EMNL/EM

2

5

9'-0"

1

A-021

3

NL/EM

NL/EM

NL/

EM

NL/EM

NL/EM

NL/EM

NL

/EM

3

4

NL/

EM

NL/

EM

NL/EM

9'-10"

WB

A-061

2

A-061

1

A-081

5

A-081

6

7 7 7 7

6

NL/EM

WB

NL/EM

1. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL WORK

ABOVE CEILING AND SHALL NOTIFY ARCHITECT OF ANY CONFLICTS

PRIOR TO INSTALLATION OF CEILING GRID, GYPSUM BOARD CEILINGS

AND SOFFITS.

2. REFER TO SHEET A-042 - FINISH PLAN FOR GYPSUM BOARD CEILINGS

AND SOFFITS

3. ALL CEILING HEIGHTS SHALL BE +9'-0" AFF UNLESS NOTED OTHERWISE

4. ALL SUSPENDED CEILING GRIDS SHALL BE DESIGNED TO RESIST

SEISMIC FORCE (FP) AS PER INTERNATIONAL BUILDING CODE, LATEST

EDITION. REFER TO DETAIL 2/A-021 FOR CEILING GRID HANGER DETAIL.

5. REFER TO ENGINEERING DRAWINGS FOR MECHANICAL, ELECTRICAL,

PLUMBING AND FIRE ALARM/SPRINKLER LAYOUTS, DETAILS AND

SCHEDULES

6. REFER TO SPECIFICATIONS FOR ALL SWITCHES, LIGHTING FIXTURES

AND EXIT SIGNS - REVISIT THIS COMMENT AFTER REVIEWING T-200

TO T-400 SPEC PAGES

7. CONTRACTOR SHALL VERIFY AND CONFIRM ALL LIGHT FIXTURES ARE IN

WORKING CONDITION WITH OPERABLE LAMPS

REFLECTED CEILING - GENERAL NOTES:

CEILING TILES TO BE INSTALLED W/ RETAINING CLIPS AT VESTIBULE

BUILDING SIGNAGE. REFER TO DETAILS ON DRAWING A-161.

36"x36" ROOF ACCESS HATCH AND LADDER SHALL BE KEPT CLEAR OF

ALL DUCTS, WIRE, CONDUITS, OR OTHER FIXED ITEMS. SEE DETAILS

ON SHEET A-032

MECHANICAL ROOM TO RECEIVE (1) LAYER OF GYP FASTENED TO

UNDERSIDE OF TRUSSES AND (1) LAYER OF GYP FASTENED TO

VERTICAL FACES OF ROOF ACCESS SHAFT. SEE DETAILS ON SHEET

A-032

5" SOFFIT @ 7'-0 1/2" A.F.F. ABOVE REFRIGERATOR & FREEZER. REFER

TO DETAIL 3/A-021.

ENTRY CANOPY

TYPICAL CANOPY

1

2

3

4

5

REFLECTED CEILING - KEY NOTES:

6

7

CEILING GRID AND TILE TO BE

INSTALLED PER ASTM C 636.

PERIMETER HANGER WIRES

TO BE PLUMB WITH 1

IN 6 UNLESS COUNTER

SLOPING WIRES ARE

PROVIDED

SUPPORT AT WALL

PER ASTM C 636

HANGER WIRES TO BE

12 GA. GALVANIZED

SOFT-ANNEALED, MILD

STEEL WIRE PER ASTM

C 636 SECTION 2.1.6.

WIRE TO BE SPACED AT

4' O.C. MAX. OR 10 GA.

AT 5' O.C. MAX (TYP.)

CONNECT TO

STRUCTURE ABOVE

USING 'HILTI X-CC' OR

APPROVED EQUAL. ALL

WIRE TIES TO BE

THREE TIGHT TURNS

AROUND ITSELF

WITHIN 3" (TYP.)

CEILING GRID AND

TILE AS SPECIFIED

STRUCTURE ABOVE

CORNER BEAD

1 LAYER OF

5

8

" GYP. BD.

ON EACH SIDE

B.O. SOFFIT

7'-0 1/2" A.F.F.

SUSPENDED CEILING

9'-0" A.F.F.

6"

MIN

MTL STUDS @ 16" O.C.

REFLECTED

CEILING PLAN

A-021

NORTH

P:\1

90

47

_T

LE

L

AN

D O

L

AK

ES

\D

RA

WIN

GS

\9

9_

TL

E_

LA

ND

OL

AK

ES

_A

RC

H\2

01

9.Q

1.0

1 G

EN

P

RO

TO

TY

PE

-A

-0

21

.D

WG

K

EL

SI P

LO

TT

ED

: 1

2/2

7/2

01

9

1. CONTRACTOR SHALL SUPERVISE AND DIRECT

THE WORK USING THE CONTRACTOR'S BEST

SKILL AND ATTENTION. THE CONTRACTOR SHALL

BE SOLELY RESPONSIBLE AND HAVE CONTROL

OVER CONSTRUCTION MEANS, METHODS

TECHNIQUES, SEQUENCE, AND JOB SITE SAFETY

2. GC MUST PROVIDE & INSTALL ALL PRODUCTS

PER PLANS. ONLY SUBSTITUTED PRODUCTS

NEED TO BE SUBMITTED TO THE ARCHITECT FOR

APPROVAL. UNAPPROVED SUBSTITUTIONS WILL

BE REPLACED AT THE EXPENSE OF THE GC.

3. VERBAL REPRESENTATION HAS NO VALUE AND

ALL REQUESTS TO CHANGE ANY PRODUCTS OR

SPECIFICATIONS PER PLANS, MUST BE

SUBMITTED IN WRITING TO THE ARCHITECT & TLE

FOR APPROVAL.

2019.Q1.01 GEN PROTOTYPE

NO. DATE DESCRIPTION INT.

REVISION

NO. DATE DESCRIPTION INT.

ISSUE

Drawing Number:

Drawing Name:

Scale:

AS NOTED

Project Number:

19047

Drawn By:

Approved By:

---

AC

AD

EM

Y O

F E

AR

LY

E

DU

CA

TIO

N

PROFESSIONAL CERTIFICATION

NAME OF LICENSEE: STEVEN VINCI

LICENSE NUMBER: AR0017036

EXPIRATION DATE: 2/28/21

FL

-564 &

B

AL

LE

NT

RA

E B

LV

D. A

T

LA

ND

O

' L

AK

ES

PA

SC

O C

OU

NT

Y, F

LO

RID

A

6699

13t

h A

venu

e N

orth

, Sui

te 4

AS

t. P

eter

sbur

g, F

L 33

710

(727

) 38

1-52

20(7

27)

381-

0052

fax

Conceptual Site Plan1 10/28/19

Schematic Design2 12/26/19

SCALE:

1

REFLECTED CEILING PLAN

1/8"=1'-0"

SCALE:

2

CEILING GRID HANGERS DETAIL

NOT TO SCALE

SCALE:

3

SOFFIT DETAIL @ PANTRY

1"= 1'-0"

SV | KT

AutoCAD SHX Text
B
AutoCAD SHX Text
u
AutoCAD SHX Text
b
AutoCAD SHX Text
b
AutoCAD SHX Text
l
AutoCAD SHX Text
e
AutoCAD SHX Text
s
Page 5: Conceptual Plan - TLE Land O Lakes - Pasco County, FL

EF-2

EF-1

RTU-1RTU-2RTU-3RTU-4RTU-5

66'-0"

22'-10"

22'-4" 22'-1"22'-4"

SL

OP

E 1/4

":12

"

SL

OP

E 1/4

":1

2"

20 GA. GALV. MTL.

DOWNSPOUT W/GALV.

MTL. SLEEVE (TYP.)

A051

3

A051

4

A051

2

A051

1

ROOF LADDER ACCESS

SEE 8/A-032 FOR DETAIL

26'-3"

19'-3"40'-1"19'-9"19'-11"33'-4"

42'-10"22'-2"

A061

1

A061

2

AWNING AT

PLAY AREA

BELOW

A-071

2

A-071

1

MANUFACTURER'S

PROTECTIVE WALKWAY

PADS

24'-5"23'-2"20'-3"44'-11"

15'-5"

A-032

4

A-032

1

AWNING AT

PLAY AREA

BELOW

4'-0" 4'-0"4'-0"

60 MIL TPO ROOF SYSTEM BY GAF (OR

APPROVED EQUAL) ON RIGID INSULATION

(R-20 MIN.). TAPER INSULATION AT

CRICKETS TO ROOF DOWNSPOUT

LOCATIONS PER THIS DRAWING.- SEE

SPECIFICATIONS.

BILCO ROOF HATCH

36"X 36" W/CURB &FLASHING.

PROVIDE LADDER UP SAFETY

POST; SLOPE ROOF AWAY

FROM HATCH- SEE SHELL

DRAWINGS

5'-0

"

11'-6"

EF-3EF-4

20 GA. GALV. MTL.

OVERFLOW SCUPPER

(TYP.)

DRYER EXHAUST DUCT;

REF MECHANICAL

GENERAL NOTES: LEGEND:

1. GENERAL CONTRACTOR SHALL FIELD VERIFY CONDITIONS AND NOTIFY ARCHITECT OF ANY

DISCREPANCIES.

2. REFER TO SPECIFICATIONS DRAWINGS FOR ADDITIONAL INFORMATION FOR ROOFING,

FLASHING REQUIREMENTS, AND MATERIALS.

3. PRIMARY ROOF SCUPPERS MUST CONNECT TO UNDERGROUND STORM SYSTEM.

DOWNSPOUTS MUST DROP THRU SIDEWALK TO CONNECT TO UNDERGROUND STORM

SYSTEM. SEE CIVIL.

4. VERIFY AND COORDINATE DUCT CURB AND ROOF PENETRATION LOCATIONS; REFER TO THE

MECHANICAL/ ELECTRICAL DRAWINGS FOR ADDITIONAL REQUIREMENTS AND COORDINATION.

5. PLUMBING VENTS OR EXHAUST VENTS ARE NOT ALLOWED WITHIN 10'-0" OF AIR INTAKES OR

5'-0" OF EXTERIOR WALLS- REFER TO MECH. DRAWINGS.

6. ALL SHEET METAL FLASHING TO COMPLY WITH THE "ARCHITECTURAL SHEET METAL MANUAL",

2012 EDITION AS PUBLISHED BY THE SHEET METAL AND AIR CONDITIONING CONTRACTIONS

NATIONAL ASSOCIATION (SMACNA).

7. ALL SHEET METAL FLASHING EXPOSED TO THE PUBLIC SHALL BE PAINTED OR PREFINISHED.

SEE BUILDING ELEVATIONS FOR COLOR SPECIFICATIONS. ALL OTHER NON EXPOSED

FLASHING TO BE GALVANIZED.

8. ALL EXHAUST FANS AND VTR'S SHALL EXTEND ABOVE ROOF PARAPET TO ENSURE EXHAUST

FUMES NOT BE CONTAINED AND TO PREVENT FROM ENTERING THE HAVC FRESH AIR INTAKES.

9. UPON COMPLETION OF CONSTRUCTION AND PRIOR TO TENANT OCCUPANCY, G.C. SHALL

ENSURE THAT THE ENTIRE ROOF, ALL GUTTERS, ROOF SCUPPERS/ DOWNSPOUTS, AND

OVERFLOW SCUPPERS ARE COMPLETELY CLEAR OF ANY AND ALL DEBRIS (CONSTRUCTION,

NATURAL, OR OTHERWISE).

10.ROOFING SUBMITTAL TO INCLUDE PRODUCT APPROVALS WITH ALL SPECIFIC PROJECT

DETAILS AND INSTALLATION INDICATED CLEARLY FOR A/E REVIEW. INDICATE WIND LOAD/

UPLIFT MEETING PROJECT DESIGN LOADS.

10.1. APPROVED ROOF MANUFACTURERS INCLUDE: GAF, FIRESTONE, AND CARLISLE

AREA TO RECEIVE- WALKWAY PADS

BASE BID FOR WALKWAY PADS TO BE ON ALL FOUR

SIDES OF HVAC EQUIPMENT

BID ADD ALTERNATE TO INCLUDE

INTERCONNECTING PADS

BETWEEN UNITS AND FOR ACCESS TO ROOF

LADDER

AREA TO RECEIVE SINGLE PLY ROOFING

MEMEBRANE

P:\1

90

47

_T

LE

L

AN

D O

L

AK

ES

\D

RA

WIN

GS

\9

9_

TL

E_

LA

ND

OL

AK

ES

_A

RC

H\2

01

9.Q

1.0

1 G

EN

P

RO

TO

TY

PE

-A

-0

31

.D

WG

K

EL

SI P

LO

TT

ED

: 1

2/2

7/2

01

9

1. CONTRACTOR SHALL SUPERVISE AND DIRECT

THE WORK USING THE CONTRACTOR'S BEST

SKILL AND ATTENTION. THE CONTRACTOR SHALL

BE SOLELY RESPONSIBLE AND HAVE CONTROL

OVER CONSTRUCTION MEANS, METHODS

TECHNIQUES, SEQUENCE, AND JOB SITE SAFETY

2. GC MUST PROVIDE & INSTALL ALL PRODUCTS

PER PLANS. ONLY SUBSTITUTED PRODUCTS

NEED TO BE SUBMITTED TO THE ARCHITECT FOR

APPROVAL. UNAPPROVED SUBSTITUTIONS WILL

BE REPLACED AT THE EXPENSE OF THE GC.

3. VERBAL REPRESENTATION HAS NO VALUE AND

ALL REQUESTS TO CHANGE ANY PRODUCTS OR

SPECIFICATIONS PER PLANS, MUST BE

SUBMITTED IN WRITING TO THE ARCHITECT & TLE

FOR APPROVAL.

2019.Q1.01 GEN PROTOTYPE

NO. DATE DESCRIPTION INT.

REVISION

NO. DATE DESCRIPTION INT.

ISSUE

Drawing Number:

Drawing Name:

Scale:

AS NOTED

Project Number:

19047

Drawn By:

Approved By:

---

AC

AD

EM

Y O

F E

AR

LY

E

DU

CA

TIO

N

PROFESSIONAL CERTIFICATION

NAME OF LICENSEE: STEVEN VINCI

LICENSE NUMBER: AR0017036

EXPIRATION DATE: 2/28/21

FL

-564 &

B

AL

LE

NT

RA

E B

LV

D. A

T

LA

ND

O

' L

AK

ES

PA

SC

O C

OU

NT

Y, F

LO

RID

A

6699

13t

h A

venu

e N

orth

, Sui

te 4

AS

t. P

eter

sbur

g, F

L 33

710

(727

) 38

1-52

20(7

27)

381-

0052

fax

Conceptual Site Plan1 10/28/19

Schematic Design2 12/26/19

NORTH

ROOF PLAN

A-031

SCALE:

1

ROOF PLAN

1/8"=1'-0"

SV | KT

AutoCAD SHX Text
B
AutoCAD SHX Text
u
AutoCAD SHX Text
b
AutoCAD SHX Text
b
AutoCAD SHX Text
l
AutoCAD SHX Text
e
AutoCAD SHX Text
s
Page 6: Conceptual Plan - TLE Land O Lakes - Pasco County, FL

1

K

K

K

K

K K

K

K K

K

K

K

K

K K

K

K

K

K

K

K

K K

K

K

K K

K

1'-9

"3

'-6

"1

'-9

"

1'-9"8'-0" 1'-9"1'-9"

3

2

SP

K

SP

K

SP

K

SP

KL L

V V

V V

V

V

V

V

V

V

V V

V

V

V

V

V

V

V V

V

V

V

V

V

V

V

VV

V

V V

V V

V

V

V V

V

V

V

V

V

V

V V

V

V

V

V

V

V

V

VV

V

VV

VV

VV

V

V

V

V

VV

V

V

VV

V

V

VV

V

V

V

V

V

V

V

V V

V

VV

VV

VV

VV

V

V

VV

V

V

VV

V

V

V

V

V

V

V

V V

V

OFFICE

102

VESTIBULE

100

RECEPTION

101

ISO

104

V

VV

VV

VV

V

L

L

1'-9"

B

B B B

VV

VV

VV

VV

K

K

K

K

K

K

K

K

K

K

K

K

K K

K

K

K K

K

K

K

K K

K

K

K

K

K

K

K K

K

K K

K

K

K

K

K K

K

K

K

K

K K

K

K

K K

K

K

K

K

K

K

K

K K

K

K K

K

K

K

K

K K

K

K

K

K

K K

K

K

K K

K

K

K

K

K

K

K

K

K

K

K

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

V V

V V

V V

V V

V V

V V

V V

V V

V V

V V

V V

V V

V V

V V

V V

V V

V V

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

VV

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SPSP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SPSP

KKKKKK

K

K

K

K

KKKKKK

K

K

K

K B

B

B

BBBB

B

B

B B B

S

SS

S

L

SP

V

L

L

L

L

LLLLLL

L

L

L

L

L L L L L

SPSPSP

SP

SP

SP SP SP SP

SP

SPV

V V

S

S

S

S

S

SSSSSS

S

S

S

S

S S S S S

K

K

K

KKKK

K

K

K K K

B B

BB

SP

SP

SP

SP

SP

SPSPSPSPSPSP

SP

SP

SP

SP

SP SP SP SP SP

V

V

V

VVVV

V

V

V V V

L L

LL

BBBBBB

B

B

B

B

B

B

B

B

BBBBBB

SSSS

S

S

S S S S

S

SK K

KK

V

V

VVVVV

V

V

V

V

V V V V V V

V

V

V

L L L L

L

L

LLLL

L

L SP SP

SPSP

KKKKKK

K

K

K

K

KKKKKK

K

K

K

K B

B

B

BBBB

B

B

B B B

S

SS

S

V

V

VVVVV

V

V

V

V

V V V V V V

V

V

V

L L L L

L

L

LLLL

L

L SP SP

SPSP

BBBBBB

B

B

B

B

B

B

B

B

BBBBBB

SSSS

S

S

S S S S

S

SK K

KK

B

B B

B

B B

BB

B

B B

B

V V

VV

V V

VV

V V

VV

V

V V

V

V

V V

V

B

B B

B

B B

BB

B

B B

B

B B

BBV

V V

V

V

V V

V

V

V V

V

V

V V

V

V

V V

V

V

V V

VB B

BB

B B

BB

B B

BB

B B

BB

BB

B

B B

B

B

B B

B

B BV V

V

V V

V

VB B V

V VB B VB B V

V VBB BB

V

V V

VB B

BB

B B

BBV

V V

V

B B

BBV

V V

V

B B

BB

B B

BBV

V V

V V

V V

V

B B

BB

B

B B

B

V

V V

V

B

B B

B B

B B

B

V

V V

V V

V V

V

B

B B

B

V V

VV

V V

VV

V V

VVB

B B

B

B

B B

B

B BV V

L L L L

L

L

LLLL

L

L

V V

VV

V

V

V

V V V V

V

V

VVV

L

L L

L

L L L L

L

L

LLLL

L

L

V V

VV

V

V

V

V V V V

V

V

VVV

L

L L

L

L L L L

L

L

LLLL

L

L

V V

VV

B B

B B

B

B

BB

B B

B

B

B B

BB

B

B

B

BB

B

B

B

B

BB

B

B

B

B

B

B

BB

B

B

B

B

B

B

B

B

B

B

B

B

B

BB

B B

B

B

B

B

B

B

B B

BB

B

B

B

B B

B

B

B

B

B

B

B B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B B

B B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

K K K K K K K K K K K K K K K K K K K K K K

KKKKKKKKKKKKKKKKKKKKKK

K

K

K

K

K

K

K

K

K

K

K

K

K

KK

K

K

K

K

K

K

K

K

K

K

K

K

K

K K K K K K K K K K K K K K K K K K

K K K K K K K K K K K K K K K K K K

K

K

K

K

K

K

K

K

K

K

K

K

B

B

B

B

B B B B B B B

B

B

B

BB

B

B

B B B B B B B B

B

B

L L L L L L

L

L

L

L

LLLLLL

L

L

L

L

PRE SCHOOL #3

110

PRE SCHOOL #2

112

TOILET

111

TOILET

115

TOILET

113

PRE SCHOOL #1

114

TODDLERS A

116

TOILET

117

TOILET

119

TODDLERS B

118

LOUNGE

122

LAUNDRY

121

PANTRY

120

ELEC

125

TOILET

124

INFANTS A

123

INFANTS B

126

MECH

128

TOILET

127

TWADDLERS

129

TOILET

131

TOILET

130

PRE-K-K

132

OFFICE

102

CL.

103

CORRIDOR

133

PREPPERS A / MBB

105

PREPPERS B

109

TOILET

106

TOILET

108

TOILET

107

FD-1

GT-1

FD-1

FD-1

FD-1

FD-1

FD-1

FD-1

FD-1

FD-1

FD-1

FD-1

FD-1

FD-1

FD-1

EQ EQ

4'-3

"

FLOOR FINISH LEGEND

INDICATE CHANGE IN FLOOR FINISH

VINYL COMPOSITION TILE (VCT) -

12x12" VINYL COMPOSITION FLOOR TILE (VCT)

REFER TO FLOOR FINISH SCHEDULE AND SPECIFICATIONS

BLANK TILES REPRESENT STANDARD COLOR THROUGHOUT

THE BUILDING. LETTERED TILES REPRESENT VARIOUS

COLORS USED FOR PATTERNS

QUARRY TILE: 6"X6" PATTERNED FACE

REFER TO FLOOR FINISH SCHEDULE AND SPECIFICATIONS

VINYL FLOORING

SOLID SHEET WITH NO SEAMS, 6" COVE BASE

REFER TO FLOOR FINISH SCHEDULE AND SPECIFICATIONS

CONCRETE FLOOR -

CONCRETE FLOOR PAINTED GRAY WITH VINYL BASE

CARPET

FLOOR DRAIN -

SEE PLUMBING DRAWINGS

GREASE TRAP -

SEE PLUMBING DRAWINGS

NOTE - SEE FLOOR FINISH SCHEDULE ON THIS PAGE FOR

CARPET AND TILE SPECIFICATIONS, INCLUDING LIST OF

COLORS.

FD-1

GT-1

FLOOR FINISH SCHEDULE

VINYL COMPOSITION FLOOR TILE (VCT):

MANUFACTURER: ARMSTRONG

TYPE: STANDARD EXCELON RAVE

SIZE: 12 IN. WIDE X 12 IN. LENGTH X

1

8

IN. THICKNESS

COLOR AND PATTERN: PROVIDE THE FOLLOWING IN LOCATIONS AS

DEPICTED ON THE DRAWINGS:

1. (W) WHITE OUT - 57518

2. (SP) SCREAMING PUMPKIN - 57516

3. (S) SHOCKING - 57514

4. (B) BIKINI BLUE - 57512

5. (L) LEMON LICK - 57509

6. (V) VICIOUS VIOLET - 57513

7. (K) KICKIN KIWI - 57510

8. BLACK #1 - 56790 (PREPPERS A / MBB)

9. (G) GRABBIN GREEN - 57511 (PREPPERS A / MBB)

ADHESIVE: S-725, WATER-RESISTANT TYPE PER MANUF.

RECOMMENDATION FOR PRODUCTS AND

SUBSTRATE

FIRE DEST DATA: ASTM E 662 SMOKE DEVELOPMENT 450 OR LESS

REFERENCE SPEC: ASTM 1066 CLASS 2 - THROUGH-PATTERN

CLEANING: VCT - IMMEDIATELY AFTER INSTALLATION, VCT SHALL BE

PROPERLY CLEANED WITH A NEUTRAL DETERGENT SOLUTION SUCH AS

ARMSTRONG S-485 COMMERCIAL FLOOR CLEANER AS PER

MANUFACTURER'S RECOMMENDATIONS/INSTRUCTIONS. VCT TO

RECEIVE HIGH QUALITY STAIN RESISTANT SEALER SUCH AS

ARMSTRONG S-495 COMMERCIAL FLOOR POLISH. AT FINAL CLEAN

PROPERLY CLEAN VCT AS PER MANUFACTURERS

RECOMMENDATIONS/INSTRUCTIONS INCLUDING THE USE OF STRIPPING

SOLUTION SUCH AS ARMSTRONG S-490 COMMERCIAL FLOOR STRIPPER.

APPLY SPECIFIED FLOOR SEALER AND (5) TO (7) COATS OF SPECIFIED

FLOOR POLISH. POLISH TO HIGH GLOSS SHINE.

SHEET VINYL FLOOR COVERING:

MANUFACTURER: SHAW

COLLECTION: VITALITY SHEET

COLOR: BENEFIT 73415

PRODUCT #: 0873V

SHEET WIDTH: AS STANDARD WITH MANUFACTURER; 12 FT.

WALL BASE: TURN UP SHEET VINYL 6" AT ALL WALLS TO

CREATE INTEGRAL COVE BASE

ACCESSORIES: CONTINUOUS BONDED PUNCTURE-PROOF

ALUMINUM REINFORCEMENT STRIP (FULL

ROOM PERIMETER)

NOTES:

1. HOMOGENOUS SHEET

2. TO BE COMMERCIAL-GRADE. INSTALL WITH NO SEAMS

3. INTEGRAL COVE BASE RADIUS SHALL NOT EXCEED 1/2" WHERE

THE WALL MEETS THE FLOOR

TO BE INSTALLED: TOILETS AND LAUNDRY ROOM

QUARRY FLOOR TILE:

MANUFACTURER: DALTILE

TYPE: INTERIOR TYPE BODY, FLAT TILE

BASE: COVED, COLOR TO MATCH FLOOR TILE

COLOR: ARID GREY

GROUT: LATICRETE

GROUT COLOR: #57 HOT COCOA

CATALOG #: 0Q42

FACE: 6"x6" PATTERNED FACE WITH STANDARD EDGE

THICKNESS: 5/16"

TO BE INSTALLED: PANTRY

RESILIENT WALL BASE AND ACCESSORIES:

MANUFACTURER: JOHNSONITE

TYPE: 4" TRADITIONAL VINYL (WITH TOE)

COLORS: 18, NAVY BLUE

162, SOVEREIGN

MIN. THICKNESS: 0.080" (2.0 mm), 0.125" (3.2 mm)

LENGTHS: MANUFACTURER'S STANDARD COILS

FIRE RATING: CLASS B

TO BE INSTALLED:

NAVY BLUE - ALL WALLS UNLESS OTHERWISE NOTED

SOVEREIGN - INDOOR PLAY AREA (IF APPLICABLE) FULL

PERIMETER AND FREESTANDING COLUMNS

CONCRETE FLOOR:

MANUFACTURER: COROTECH (BENJAMIN MOORE)

TYPE: WATERBORNE AMINE EPOXY V440

COLORS: BATTLESHIP GRAY (75)

PINK RASPBERRY (2075-40)

INSTALLATION: FULL COVERAGE; APPLY MIN. TWO (2) COATS

TO BE INSTALLED:

BATTLESHIP GRAY (75) - ELECTRICAL CLOSET, JANITOR'S

CLOSET, AND MECHANICAL ROOM

PINK RASPBERRY (2075-40) - INDOOR PLAY AREA (IF

APPLICABLE) FULL EXTENTS OF UNITY

SURFACING

CARPET: (REQUIRED)

MANUFACTURER: INTERFACE

CONTACT: GLENDA KISNER

PHONE: 305.710.5105

EMAIL: [email protected]

STOCK HOLD: #3141

IDENTIFICATION #: CONTACT REQUIRED VENDOR

FIRE RATING: CLASS A

FIRE TESTING: FLOORING RADIANT PANEL (ASTM E-648) PASSES

SMOKE DENSITY (ASTM E-662) ≤ 450

FLAMMABILITY / PILL TEST (DOC-FF1-70) PASSES

OFFICE & CLASSROOM CARPET (REQUIRED):

CARPET TYPE: CARPET TILES, GLASBAC

PRODUCT NAME & #: GATHER 19DR402500

COLOR: 180784 MARINE ACCENT

TO BE INSTALLED: IN OFFICE AND ALL CLASSROOMS (NOT

INFANT) PER PLAN

TO BE INSTALLED: QUARTER TURN

TO BE INSTALLED: xL2000 DIRECT GLUE DOWN METHOD

K

S

V

B

L

G

BK

SP

1. GENERAL CONTRACTOR SHALL FIELD VERIFY CONDITIONS

AND NOTIFY ARCHITECT OF ANY DISCREPANCIES.

2. ALL FLOORS SHALL BE PROPERLY PREPARED AND SKIM

COATED AS NECESSARY TO ACHIEVE CLEAN SURFACES SO

THAT BLEMISHES DO NOT TELEGRAPH THROUGH FINISH

MATERIAL.

3. CONTRACTOR SHALL SUBMIT SAMPLES OF ANY ALTERNATE

FINISHES TO ARCHITECT FOR APPROVAL PRIOR TO

ORDERING MATERIALS. SEE SPECIFICATIONS DRAWINGS

FOR SUBMITTAL PROCEDURE.

4. PROVIDE RUBBER TRANSITION STRIP AT JUNCTION OF

CARPET AND VCT. REFER TO DOOR AND HARDWARE

SCHEDULE FOR FURTHER INFORMATION.

5. ALL FLOOR FINISH CHANGES AT DOORWAYS SHALL BE

CENTERED UNDER DOOR. PATTERN TO BE CENTERED

UNDER DOOR.

6. CARPET TO BE INSTALLED AT END OF CONSTRUCTION AND

PROTECTED FROM ANY DEBRIS. CARPETS TO BE

THOROUGHLY VACUUMED AT THE COMPLETION OF

CONSTRUCTION.

7. ALL UNLABELED FLOOR FINISHES TO BE ARMSTRONG,

STANDARD EXCELON RAVE, (W) WHITE OUT - 57518, UNLESS

OTHERWISE NOTED.

8. ALL VCT FLOORS TO BE WAXED MIN. 5 COATS WITH

ARMSTRONG S-495 COMMERCIAL FLOOR POLISH.

9. REFER TO A-121 FOR TRANSITION DETAILS

FLOOR FINISH GENERAL NOTES:FLOOR FINISH KEY NOTES

PROVIDE WALK-OFF MAT - SEE FLOOR FINISH SCHEDULE

FOR SPECIFICATIONS

RECEPTION AREA CUSTOM VCT LOGO SHALL BE

PURCHASED FROM REQUIRED CARPET VENDOR. REFER

TO CONTACT INFORMATION.

PREPPERS A / MBB RACETRACK:

· CENTER OVAL: VCT COLOR "G" (PER FINISH SCHED.)

· ROADWAY: VCT COLOR "BLACK #1" (PER FINISH

SCHED.)

· LANE STRIPING: VCT COLOR "L" (PER FINISH SCHED),

APPROX. 1" WIDE BY 6" LONG WITH A 3" SPACE

BETWEEN EACH STRIPE

1

2

3

INTERIOR FINISH TESTING REQUIREMENTS:

1. CARPET, PADDING, WALK-OFF MAT, AND ANY OTHER

FIBER-BASED FLOOR FINISHES SHALL BE CLASS 1 OR CLASS

II AS TESTED PER NFPA 253.

2. WALL BASE FINISHES (6"H OR LESS) SHALL BE CLASS I OR

CLASS II AS TESTED PER NFPA 253.

3. FLAME SPREAD INDEX AND SMOKE DEVELOPED RATING:

· WALL AND CEILING FINISH MATERIALS SHALL BE MINIMUM

CLASS B:

FLAME SPREAD: < 75

SMOKE DEVELOPED INDEX: < 450

· INTERIOR TRIM MATERIALS SHALL BE MINIMUM CLASS C:

FLAME SPREAD: < 200

SMOKE DEVELOPED INDEX: < 450

INFANT ROOMS ONLY CARPET(REQUIRED):

CARPET TYPE: CARPET TILES, CUSHION BAC RENEW

PRODUCT NAME & #: GATHER 19DR402500

COLOR: 180784 MARINE ACCENT

TO BE INSTALLED: IN ALL INFANT CLASSROOMS PER PLAN

TO BE INSTALLED: QUARTER TURN

TO BE INSTALLED: xL2000 DIRECT GLUE DOWN METHOD

WALK-OFF MAT:

MANUFACTURER: AMARCO

STYLE: INDIVIDUAL 24" TILES, 1/4 TURN

COLOR: STEEL BLUE #64

FIRE TEST DATA: ASTM D2859- PILL TEST (SURFACE

FLAMMABILITY)

TO BE INSTALLED: VESTIBULE

TRANSITION STRIPS:

DESCRIPTION: REFER TO SHEET A-121 FOR MORE

INFORMATION.

COLOR: TO MATCH VINYL COVE BASE.

NOTE:

TLE VCT LOGO & MBB RACETRACK CARPET MUST BE PURCHASED FROM

REQUIRED VENDOR. NO SUBSTITUTIONS ALLOWED.

SHEHADI COMMERCIAL CARPET & FLOORING

ATTN: GEORGE SKURCHAK

23 JUST ROAD PH. 973-808-4443 EXT. 13

FAIRFIELD, NJ 07004 FAX. 973-808-4493

FLOOR FINISH

PLAN

A-041

P:\1

90

47

_T

LE

L

AN

D O

L

AK

ES

\D

RA

WIN

GS

\9

9_

TL

E_

LA

ND

OL

AK

ES

_A

RC

H\2

01

9.Q

1.0

1 G

EN

P

RO

TO

TY

PE

-A

-0

41

.D

WG

K

EL

SI P

LO

TT

ED

: 1

2/2

7/2

01

9

1. CONTRACTOR SHALL SUPERVISE AND DIRECT

THE WORK USING THE CONTRACTOR'S BEST

SKILL AND ATTENTION. THE CONTRACTOR SHALL

BE SOLELY RESPONSIBLE AND HAVE CONTROL

OVER CONSTRUCTION MEANS, METHODS

TECHNIQUES, SEQUENCE, AND JOB SITE SAFETY

2. GC MUST PROVIDE & INSTALL ALL PRODUCTS

PER PLANS. ONLY SUBSTITUTED PRODUCTS

NEED TO BE SUBMITTED TO THE ARCHITECT FOR

APPROVAL. UNAPPROVED SUBSTITUTIONS WILL

BE REPLACED AT THE EXPENSE OF THE GC.

3. VERBAL REPRESENTATION HAS NO VALUE AND

ALL REQUESTS TO CHANGE ANY PRODUCTS OR

SPECIFICATIONS PER PLANS, MUST BE

SUBMITTED IN WRITING TO THE ARCHITECT & TLE

FOR APPROVAL.

2019.Q1.01 GEN PROTOTYPE

NO. DATE DESCRIPTION INT.

REVISION

NO. DATE DESCRIPTION INT.

ISSUE

Drawing Number:

Drawing Name:

Scale:

AS NOTED

Project Number:

19047

Drawn By:

Approved By:

---

AC

AD

EM

Y O

F E

AR

LY

E

DU

CA

TIO

N

PROFESSIONAL CERTIFICATION

NAME OF LICENSEE: STEVEN VINCI

LICENSE NUMBER: AR0017036

EXPIRATION DATE: 2/28/21

FL

-564 &

B

AL

LE

NT

RA

E B

LV

D. A

T

LA

ND

O

' L

AK

ES

PA

SC

O C

OU

NT

Y, F

LO

RID

A

6699

13t

h A

venu

e N

orth

, Sui

te 4

AS

t. P

eter

sbur

g, F

L 33

710

(727

) 38

1-52

20(7

27)

381-

0052

fax

Conceptual Site Plan1 10/28/19

Schematic Design2 12/26/19

NORTH SCALE:

1

FLOOR FINISH PLAN

1/8"=1'-0"

KT

AutoCAD SHX Text
B
AutoCAD SHX Text
u
AutoCAD SHX Text
b
AutoCAD SHX Text
b
AutoCAD SHX Text
l
AutoCAD SHX Text
e
AutoCAD SHX Text
s
Page 7: Conceptual Plan - TLE Land O Lakes - Pasco County, FL

456

MA

KE

BE

LIE

VE

BLV

D.

GA

RA

GE

DIN

ER

GE

NE

RA

L

ST

OR

E

FIRE

STATION

BC-12 BC-12

BC

-8

BC-8

BC

-8

BC-8BC-10BC-10

BC-10BC-10 BC-8BC-8BC-10

BS

-1

0

BC-8

BC

-8

BC

-8

BC-10BC-10

BC-10

BS

-1

0

BC-8

PRE SCHOOL #3

110

PRE SCHOOL #2

112

TOILET

111

TOILET

115

TOILET

113

PRE SCHOOL #1

114

TODDLERS A

116

TOILET

117

TOILET

119

TODDLERS B

118

LOUNGE

122

LAUNDRY

121

PANTRY

120

ELEC

125

TOILET

124

INFANTS A

123

INFANTS B

126

MECH

128

TOILET

127

TWADDLERS

129

TOILET

131

TOILET

130

PRE-K-K

132

OFFICE

102

VESTIBULE

100

RECEPTION

101

CL.

103

ISO

104

CORRIDOR

133

PREPPERS A / MBB

105

PREPPERS B

109

TOILET

106

TOILET

108

TOILET

107

BS

-1

0

BC-10

4 4

4

4

4

C

A

AH

M

H

M

A

M D

C

D

H

AH

C

C

M

HAM

D

MA

C

A

H

DA

M

C

D

2

3

D

D

M

H

M

C

A

D

1

1

D

A

M

M

A

M

H

M

A

C

AH

CM

AH

H

MAC

A

M

A

H

D

M

C

D

4

4

4

4

4

4

4

PAINT FINISH SCHEDULE

FINISH

CODE

COLOR

BENJAMIN MOORE SHERWIN WILLIAMS PPG PAINTS

COLOR NAME STOCK NO. COLOR NAME STOCK NO. COLOR NAME STOCK NO.

W WHITE WHITE DOVE OC 17 GREEK VILLA 7551 WHITE DOVE CM BM

M ORANGE MANGO PUNCH 154 OSAGE ORANGE 6890 OSAGE ORANGE CM SW

H PURPLE HYDRANGEA 1390 BERRY FRAPPE 9068 BERRY FRAPPE CM SW

D YELLOW VIKING YELLOW 321 CHEERFUL 6903 FLIRTATIOUS 1212-7

C GREEN CANDY GREEN 403 PRIMAVERA 9031 GOODY GUMDROP 1219-4

A BLUE ATLANTIS BLUE 768 FOUNTAIN 6787 FOUNTAIN CM SW

PAINT FINISH SCHEDULE NOTES:

1. PAINT FINISH:

a. H.M. DOOR AND WINDOW FRAMES SHALL BE SEMI-GLOSS FINISH.

b. ALL OTHER PAINT SHALL BE EGGSHELL FINISH.

c. ALL STOREFRONT (ALUMINUM/GLASS) DOORS SHALL BE FINISHED PER DOOR SCHEDULE (SHEET A-121)

2. ALL PAINTED SURFACES SHALL RECEIVE MINIMUM ONE COAT OF PRIMER AND TWO COATS OF PAINT

(UNLESS FACTORY PRIMED BY THE MANUFACTURER). REFER TO SPECIFICATIONS DRAWINGS FOR

ADDITIONAL INFORMATION.

3. SELECTED COLOR PALETTE SHALL BE FROM ONE OF THE ABOVE MANUFACTURERS.

4. NO SUBSTITUTIONS WILL BE ALLOWED.

"CM BM" = COLOR MATCH BENJAMIN MOORE

"CM SW" = COLOR MATCH SHERWIN WILLIAMS

*

W

SUSPENDED

CEILING

*

W

3'-1

0"

REFER TO A-012 FOR WIDTH

VARIES

W = PER PAINT FINISH SCHEDULE

* = COLOR DESIGNATED ON PAINT FINISH PLAN

ALSO REFER TO GENERAL NOTE #5

30'-0" MAX. BETWEEN DRYWALL CONTROL JOINTS

DRYWALL CONTROL

JOINT ALIGNED WITH

DOOR JAMB (REF. A-011)

DRYWALL CONTROL JOINT

ALIGNED WITH WINDOW

JAMB (REF. A-011)

PAINT FINISH LEGEND:

W

W

W

DOOR AND FRAME - BOTH SIDES

INTERIOR WINDOW AND FRAME- BOTH SIDES

WALL AND GYPSUM BOARD SOFFIT

WALL FINISH GENERAL NOTES:

1. PRIOR TO COMMENCEMENT OF PAINTING, THE GC. SHALL BE RESPONSIBLE FOR THE

FOLLOWING:

a. FIELD VERIFY THAT ALL SURFACES ARE READY TO ACCEPT PAINTS- NOTIFY

ARCHITECT OF ANY DISCREPANCIES

b. REMOVE OR PROTECT ALL ELECTRIC SWITCHES, OUTLETS, PLATES, SURFACE

HARDWARE, ETC.

c. GC. TO PROTECT ALL ADJACENT SURFACES AS REQUIRED DURING PAINTING.

2. CONTRACTOR SHALL SUPPLY ALL PAINT AND MATERIALS AS PER PAINT FINISH SCHEDULE

AND PAINT FINISH LEGEND. ALL PAINT AND MATERIAL MUST BE DELIVERED TO THE JOB

SITE IN THE MANUFACTURER'S ORIGINAL PACKAGING- NO SUBSTITUTIONS ALLOWED.

3. ALL HOLLOW METAL DOORS, DOOR FRAMES, AND INTERIOR WINDOW FRAMES ARE TO BE

FACTORY PRIMED AND FIELD PAINTED ON BOTH SIDES.

a. INTERIOR DOORS, DOOR FRAMES, AND INTERIOR WINDOW FRAMES SHALL BE

PAINTED THE SAME COLOR ON BOTH SIDES UNLESS OTHERWISE INDICATED ON

FINISH PLAN.

4. AREAS LISTED BELOW TO BE PAINTED WITH ONE PRIMER COAT AND TWO FINISH COATS

OF "W" ON PAINT FINISH LEGEND AND SCHEDULE

a. CLOSET INTERIOR WALLS

b. TOILET INTERIOR WALLS

c. MECHANICAL ROOM INTERIOR WALLS

d. ALL SURFACES, UNLESS NOTED OTHERWISE.

e. GYPSUM SOFFIT (ALL SIDES) UNLESS NOTED OTHERWISE

5. ALL WALLS TO BE PAINTED AS PER PAINT FINISH SCHEDULE UNLESS NOTED OTHERWISE.

6. CORRIDOR WALLS: REFER TO CORRIDOR FINISH DETAIL 2/A-042.

7. PREPPERS A / MBB: ALL WALLS ARE TO BE PAINTED "W" AS PER PAINT FINISH SCHEDULE.

PREPPERS A / MBB FACADE MANUFACTURER SHALL PROVIDE FACADE AND A TOUCH-UP

KIT WITH ALL NECESSARY COLORS IN SEMI GLOSS FINISH.

8. ALL FINISH WORK SHALL BE APPLIED FREE OF SAGS, RUNS, STREAKS, BRUSH OR ROLLER

MARKS ETC.

9. UPON COMPLETION, THE GENERAL CONTRACTOR SHALL

a. REMOVE ALL PAINT FROM WHERE IT HAS SPILLED, SPLASHED, OR SPLATTERED ON

SURFACES, INCLUDING LIGHT FIXTURES, DIFFUSERS, SLAB FITTINGS, ETC.,

b. REINSTALL AND/OR REPLACE ANY DAMAGED ELECTRIC SWITCHES, OUTLETS,

PLATES, SURFACE HARDWARE, ETC. AFTER PAINT COMPLETION.

CHAIR RAIL TO BE PAINTED "W" PER PAINT FINISH SCHEDULE.

WALL FINISH KEY NOTES

1

2

3

4

IN PANTRY, ALL WALLS INCLUDING SPLASH AREAS ABOVE COUNTER, TO

RECEIVE F.R.P. TO 7'-6" A.F.F., REFER TO WALL FINISH SCHEDULE (THIS PAGE)

AND PANTRY DETAILS A-133 FOR ADDITIONAL INFORMATION.

FRP TO BE INSTALLED IN LAUNDRY ROOM AND JANITOR'S CLOSET ON WALL

BEHIND SINK AND 3' EACH SIDE OF SINK TO 7'-6" A.F.F. REFER TO WALL FINISH

SCHEDULE (THIS PAGE).

FRP TO BE INSTALLED IN TOILET ROOMS ON WET WALL(S) AND ADJACENT

WALL(S) TO A MINIMUM HEIGHT OF 4'-4" A.F.F. REFER TO WALL FINISH

SCHEDULE (THIS PAGE).

FIBERGLASS REINFORCED PLASTIC PANELS (FRP):

MANUFACTURER: CRANE COMPOSITES

PRODUCT: KEMPLY FIBERGLASS LAMINATED WALL PANEL

PRODUCT CODE: KEM

FINISH: WHITE, STIPPLE

FIRE RATING: CLASS A

INTERIOR PAINT: (NO SUBSTITUTIONS ALLOWED)

MANUFACTURER: BENJAMIN MOORE

PRODUCTS:

· TYPICAL PRIMER: ULTRA SPEC INTERIOR PRIMER 534

· TYPICAL PAINT: ULTRA SPEC INTERIOR EGGSHELL 538

· WOOD: N319 REGAL SATIN/ EGGSHELL

· H.M. DOORS/FRAMES: SUPER SPEC HP P29 DTM ACRYLIC (SEMI-GLOSS)

OR

MANUFACTURER: SHERWIN WILLIAMS

PRODUCTS:

· TYPICAL PRIMER: PROMAR 200 ZERO V.O.C. PRIMER

· TYPICAL PAINT: PROMAR 200 ZERO V.O.C. INTERIOR LOW GLOSS EG-SHEL

· WOOD: PROMAR 200 ZERO V.O.C. INTERIOR LOW GLOSS EG-SHEL

· H.M. DOORS/FRAMES: PRO INDUSTRIAL DTM ACRYLIC (SEMI-GLOSS)

CARPET:

REFER TO FLOOR FINISH SCHEDULE FOR PRODUCT SPECIFICATION.

CARPET REQUIRED AT ALL FREESTANDING COLUMNS

· TO A HEIGHT OF 3'-6"

· ONLY APPLIES IF FREESTANDING COLUMNS SHOWN ON PLAN

· EXCLUDES PREPPERS B AND INDOOR PLAY AREAS

WALL FINISH SCHEDULE:

NORTH

WALL FINISH

PLAN

A-042

P:\1

90

47

_T

LE

L

AN

D O

L

AK

ES

\D

RA

WIN

GS

\9

9_

TL

E_

LA

ND

OL

AK

ES

_A

RC

H\2

01

9.Q

1.0

1 G

EN

P

RO

TO

TY

PE

-A

-0

42

.D

WG

K

EL

SI P

LO

TT

ED

: 1

2/2

6/2

01

9

1. CONTRACTOR SHALL SUPERVISE AND DIRECT

THE WORK USING THE CONTRACTOR'S BEST

SKILL AND ATTENTION. THE CONTRACTOR SHALL

BE SOLELY RESPONSIBLE AND HAVE CONTROL

OVER CONSTRUCTION MEANS, METHODS

TECHNIQUES, SEQUENCE, AND JOB SITE SAFETY

2. GC MUST PROVIDE & INSTALL ALL PRODUCTS

PER PLANS. ONLY SUBSTITUTED PRODUCTS

NEED TO BE SUBMITTED TO THE ARCHITECT FOR

APPROVAL. UNAPPROVED SUBSTITUTIONS WILL

BE REPLACED AT THE EXPENSE OF THE GC.

3. VERBAL REPRESENTATION HAS NO VALUE AND

ALL REQUESTS TO CHANGE ANY PRODUCTS OR

SPECIFICATIONS PER PLANS, MUST BE

SUBMITTED IN WRITING TO THE ARCHITECT & TLE

FOR APPROVAL.

2019.Q1.01 GEN PROTOTYPE

NO. DATE DESCRIPTION INT.

REVISION

NO. DATE DESCRIPTION INT.

ISSUE

Drawing Number:

Drawing Name:

Scale:

AS NOTED

Project Number:

190--

Drawn By:

Approved By:

---

AC

AD

EM

Y O

F E

AR

LY

E

DU

CA

TIO

N

PROFESSIONAL CERTIFICATION

NAME OF LICENSEE: STEVEN VINCI

LICENSE NUMBER: AR0017036

EXPIRATION DATE: 2/28/21

FL

-564 &

B

AL

LE

NT

RA

E B

LV

D. A

T

LA

ND

O

' L

AK

ES

PA

SC

O C

OU

NT

Y, F

LO

RID

A

6699

13t

h A

venu

e N

orth

, Sui

te 4

AS

t. P

eter

sbur

g, F

L 33

710

(727

) 38

1-52

20(7

27)

381-

0052

fax

Conceptual Site Plan1 10/28/19

Schematic Design2 12/26/19

SCALE:

1

WALL FINISH PLAN

1/8"=1'-0"

SCALE:

2

CORRIDOR FINISH DETAIL

1/8"=1'-0"

KT

AutoCAD SHX Text
P
AutoCAD SHX Text
P
AutoCAD SHX Text
W
AutoCAD SHX Text
D
AutoCAD SHX Text
K-12100-C
AutoCAD SHX Text
FREEWILL
AutoCAD SHX Text
SHOWERS
AutoCAD SHX Text
ACRYLIC
AutoCAD SHX Text
B
AutoCAD SHX Text
u
AutoCAD SHX Text
b
AutoCAD SHX Text
b
AutoCAD SHX Text
l
AutoCAD SHX Text
e
AutoCAD SHX Text
s
Page 8: Conceptual Plan - TLE Land O Lakes - Pasco County, FL

LINE OF FINISH

FLOOR- 0'-0"

T.O. SILL 3'-4"

DOORS & WINDOWS

HEADERS 8'-0"

3335

OVERALL HEIGHT 20'-2"

T.O. LOWER PARAPET

OVERALL HEIGHT 23'-6"

T.O. UPPER PARAPET

B.O. TYP CANOPY 9'-4"

B.O. MAIN ENTRY

CANOPY 10'-8"

3

1

2

4

C

A

B

D

EIFS-1

CANOPY BRICKBRICKEIFS 2 EIFS 2 KNOX-1ADDRESS

STUCCO CANOPY EIFS-1

CANOPY EIFS 2

STUCCOCANOPY

HOSE BIBB

WEATHERPROOF RECEPTACLE

(TYP; REF. ELEC. DWGS.)

INTERNALLY LIT LED SIGN

35 SF - REF. 3/A-161

FIXED WINDOW

(TYP.)

KEYCODE

LOCKBOX

EIFS 2 EIFS 2 EIFS 2

BRICK

Academy of Early Education

3'-7

"

10'-0"

LINE OF FINISH

FLOOR- 0'-0"

B.O. SILL 3'-4"

DOORS & WINDOWS

HEADERS 7'-4"

OVERALL HEIGHT 20'-2"

T.O. UPPER PARAPET

HOSE BIBB

REVEALBRICK

STUCCO EIFS-1SCONCE

DRINKING FOUNTAIN

AWNING AT PLAY AREA (2 TYP.)

REFER TO A-152 FOR ADDITIONAL

INFORMATION AND DETAILS

WEATHERPROOF

RECEPTACLE (2 TYP;

REF. ELEC. DWGS.)

HOSE BIBB

4'-4

"

CALL BOX- REFER TO ELEC. DWG

FOR ADDITIONAL INFORMATION

KEY FOB- REFER TO ELEC. DWG

FOR ADDITIONAL INFORMATION

FIXED

WINDOW

(TYP.)

MTL DOWNSPOUT (TYP.)

COLOR: WHITE

±4

'-4

"

WATER PLAY CONTROL BOX;

COORDINATE WITH VENDOR

FOR EXACT LOCATION

DRINKING FOUNTAIN

WEATHERPROOF

RECEPTACLE (2 TYP;

REF. ELEC. DWGS.)

HOSE BIBB

SCJ

3'-0" 3'-0"

12

'-5

"

OVERALL HEIGHT 20'-2"

B.O. SILL 3'-4"

T.O. UPPER PARAPET

OVERALL HEIGHT 23'-6"

T.O. UPPER PARAPET

OVERALL HEIGHT 25'-6"

T.O. UPPER PARAPET

LINE OF FINISH

FLOOR- 0'-0"

DOORS & WINDOWS

HEADERS 7'-4"

B.O. TYP CANOPY 9'-4"

B.O. MAIN ENTRY

CANOPY 10'-8"

SCONCE EIFS-1

BRICK

STUCCO

STUCCO

EIFS 2REVEAL

35'-0"35'-0"

LINE OF FINISH FLOOR- 0'-0"

T.O. SILL 3'-4"

OVERALL HEIGHT 23'-6"

T.O. UPPER PARAPET

OVERALL HEIGHT 25'-6"

T.O. UPPER PARAPET

DOORS & WINDOWS HEADERS 7'-4"

OVERALL HEIGHT 20'-2"

T.O. UPPER PARAPET

B.O. TYP CANOPY 9'-4"

B.O. MAIN ENTRY

CANOPY 10'-8"

DISCONNECT.

METER

EIFS 2

STUCCO

EIFS-1

REVEALBRICK

BRICK

KNOX-2

FIXED

WINDOW

(TYP.)

5'-0

"

41'-8"41'-8"

EXTERIOR MATERIAL SCHEDULE

LABEL MANUFACTURER SIZE/TYPE FINISH COLOR

STOREFRONT KAWNEER IMPACT RESISTANT ANODIZED ALUMINUM

DOOR - PER DOOR SCHEDULE FACTORY PRIMED

FIXED WINDOW KAWNEER PER WINDOW SCHEDULE ANODIZED ALUMINUM

STUCCO SMOOTH FINISH SW 7504 KEYSTONE GRAY

BRICK VENEER THIN BRICK BY WATSONTOWN MANHATTAN SERIES "WHITE"

EIFS CORNICE & TRIM SMOOTH FINISH SW 7570 EGRET WHITE

EIFS WATER TABLE ROUGH FINISH SW 7504 KEYSTONE GRAY

COVERED ENTRY CANOPY ALUMINUM POWDER COATED ALUMINUM

BAHAMA CANOPY ALUMINUM POWDER COATED ALUMINUM

SERGE FERRARI FABRIC SOLTIS PROOF 502 BLACK

1" PVC REVEAL --- WHITE

PVC STUCCO CONTROL --- WHITE

KNOX BOX 3200 SERIES W/ RECESSED COLOR: DARK BRONZE

(MAIN ENTRY) MOUNT FLANGE, HINGE DOOR, (REF. NOTE 2 BELOW)

& TAMPER SWITCH

KNOX BOX 1650 SERIES W/ RECESSED COLOR: DARK BRONZE

(MECHANICAL ROOM) MOUNT FLANGE, HINGE DOOR, (REF. NOTE 2 BELOW)

& TAMPER SWITCH

ADDRESS 6" NUMBERS ON 1" STANDOFFS BLACK

FINISH SCHEDULE NOTES:

1. G.C. SHALL VERIFY KNOX BOX MODEL(S) AND LOCATION(S) WITH AUTHORITY HAVING JURISDICTION PRIOR TO

ORDERING/INSTALLATION.

2. G.C. SHALL ENSURE ALL EXTERIOR FINISHES ARE INSTALLED AND FINISHED IN COMPLIANCE WITH

MANUFACTURERS' WARRANTY REQUIREMENTS.

STUCCO

ENTRY

REVEAL

SCJ

KNOX-1

KNOX-2

EIFS 1

EIFS 2

AWNING

BRICK

CANOPY

ADDRESS

CYPRESS RANCH DEVELOPMENT STANDARDS

ARCHITECTURAL STANDARDS (SECTION 4.3): BUILDING MATERIALS

1/A-051 FRONT FACADE (EXCLUDING OPENINGS):

TOTAL AREA = 3,062 S.F.

50% OF TOTAL AREA = 1,531 S.F.

BRICK AREA = 1,904 S.F.

STUCCO/EIFS AREA = 1,158 S.F.

2/A-051 REAR FACADE (EXCLUDING OPENINGS):

TOTAL AREA = 2,670 S.F.

50% OF TOTAL AREA = 1,335 S.F.

BRICK AREA = 1,492 S.F.

STUCCO/EIFS AREA = 1,178 S.F.

3/A-051 SIDE FACADE (EXCLUDING OPENINGS):

TOTAL AREA = 1,396 S.F.

50% OF TOTAL AREA = 698 S.F.

BRICK AREA = 715 S.F.

STUCCO/EIFS AREA = 581 S.F.

4/A-051 SIDE FACADE (EXCLUDING OPENINGS):

TOTAL AREA = 1,307 S.F.

50% OF TOTAL AREA = 654 S.F.

BRICK AREA = 767 S.F.

STUCCO/EIFS AREA = 540 S.F.

P:\1

90

47

_T

LE

L

AN

D O

L

AK

ES

\D

RA

WIN

GS

\9

9_

TL

E_

LA

ND

OL

AK

ES

_A

RC

H\2

01

9.Q

1.0

1 G

EN

P

RO

TO

TY

PE

-A

-0

51

.D

WG

K

EL

SI P

LO

TT

ED

: 1

2/2

7/2

01

9

1. CONTRACTOR SHALL SUPERVISE AND DIRECT

THE WORK USING THE CONTRACTOR'S BEST

SKILL AND ATTENTION. THE CONTRACTOR SHALL

BE SOLELY RESPONSIBLE AND HAVE CONTROL

OVER CONSTRUCTION MEANS, METHODS

TECHNIQUES, SEQUENCE, AND JOB SITE SAFETY

2. GC MUST PROVIDE & INSTALL ALL PRODUCTS

PER PLANS. ONLY SUBSTITUTED PRODUCTS

NEED TO BE SUBMITTED TO THE ARCHITECT FOR

APPROVAL. UNAPPROVED SUBSTITUTIONS WILL

BE REPLACED AT THE EXPENSE OF THE GC.

3. VERBAL REPRESENTATION HAS NO VALUE AND

ALL REQUESTS TO CHANGE ANY PRODUCTS OR

SPECIFICATIONS PER PLANS, MUST BE

SUBMITTED IN WRITING TO THE ARCHITECT & TLE

FOR APPROVAL.

2019.Q1.01 GEN PROTOTYPE

NO. DATE DESCRIPTION INT.

REVISION

NO. DATE DESCRIPTION INT.

ISSUE

Drawing Number:

Drawing Name:

Scale:

AS NOTED

Project Number:

19047

Drawn By:

Approved By:

---

AC

AD

EM

Y O

F E

AR

LY

E

DU

CA

TIO

N

PROFESSIONAL CERTIFICATION

NAME OF LICENSEE: STEVEN VINCI

LICENSE NUMBER: AR0017036

EXPIRATION DATE: 2/28/21

FL

-564 &

B

AL

LE

NT

RA

E B

LV

D. A

T

LA

ND

O

' L

AK

ES

PA

SC

O C

OU

NT

Y, F

LO

RID

A

6699

13t

h A

venu

e N

orth

, Sui

te 4

AS

t. P

eter

sbur

g, F

L 33

710

(727

) 38

1-52

20(7

27)

381-

0052

fax

Conceptual Site Plan1 10/28/19

Schematic Design2 12/26/19

EXTERIOR

ELEVATIONS

A-051

SCALE:

1

FRONT ELEVATION

1/8"=1'-0"

SCALE:

2

REAR ELEVATION

1/8"=1'-0"

SCALE:

3

SIDE ELEVATION

1/8"=1'-0"

SCALE:

4

SIDE ELEVATION

1/8"=1'-0"

KT | SV

AutoCAD SHX Text
1
AutoCAD SHX Text
A-061
AutoCAD SHX Text
A-141
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
A-071
AutoCAD SHX Text
B
AutoCAD SHX Text
u
AutoCAD SHX Text
b
AutoCAD SHX Text
b
AutoCAD SHX Text
l
AutoCAD SHX Text
e
AutoCAD SHX Text
s
AutoCAD SHX Text
1
AutoCAD SHX Text
A-061
AutoCAD SHX Text
1
AutoCAD SHX Text
A-071
AutoCAD SHX Text
2
AutoCAD SHX Text
A-061
AutoCAD SHX Text
2
AutoCAD SHX Text
A-061
AutoCAD SHX Text
B
AutoCAD SHX Text
u
AutoCAD SHX Text
b
AutoCAD SHX Text
b
AutoCAD SHX Text
l
AutoCAD SHX Text
e
AutoCAD SHX Text
s
Page 9: Conceptual Plan - TLE Land O Lakes - Pasco County, FL

3335

3

1

2

4

C

A

B

D

LINE OF FINISH

FLOOR- 0'-0"

T.O. SILL 3'-4"

DOORS & WINDOWS

HEADERS 8'-0"

3'-7

"

10'-0"

OVERALL HEIGHT 20'-2"

T.O. LOWER PARAPET

OVERALL HEIGHT 23'-6"

T.O. UPPER PARAPET

EIFS-1

CANOPY

B.O. TYP CANOPY 9'-4"

B.O. MAIN ENTRY

CANOPY 10'-8"

BRICKBRICKEIFS 2 EIFS 2 KNOX-1ADDRESS

STUCCO CANOPY EIFS-1

CANOPY EIFS 2

STUCCOCANOPY

5'-0

"

HOSE BIBB

WEATHERPROOF RECEPTACLE

(TYP; REF. ELEC. DWGS.)

INTERNALLY LIT LED SIGN

35 SF - REF. 3/A-161

FIXED WINDOW

(TYP.)

KEYCODE

LOCKBOX

EIFS 2 EIFS 2 EIFS 2

BRICK

LINE OF FINISH

FLOOR- 0'-0"

B.O. SILL 3'-4"

DOORS & WINDOWS

HEADERS 7'-4"

OVERALL HEIGHT 20'-2"

T.O. UPPER PARAPET

REVEALBRICK

STUCCO EIFS-1SCONCE

DRINKING FOUNTAIN

AWNING AT PLAY AREA (2 TYP.)

REFER TO A-152 FOR ADDITIONAL

INFORMATION AND DETAILS

WEATHERPROOF

RECEPTACLE (2 TYP;

REF. ELEC. DWGS.)

HOSE BIBB

4'-4

"

CALL BOX- REFER TO ELEC. DWG

FOR ADDITIONAL INFORMATION

KEY FOB- REFER TO ELEC. DWG

FOR ADDITIONAL INFORMATION

FIXED

WINDOW

(TYP.)

MTL DOWNSPOUT (TYP.)

COLOR: WHITE

±4

'-4

"

WATER PLAY CONTROL BOX;

COORDINATE WITH VENDOR

FOR EXACT LOCATION

DRINKING FOUNTAIN

WEATHERPROOF

RECEPTACLE (2 TYP;

REF. ELEC. DWGS.)

HOSE BIBB

3'-0"

3'-0"

SCJ

12

'-5

"

OVERALL HEIGHT 20'-2"

B.O. SILL 3'-4"

T.O. UPPER PARAPET

OVERALL HEIGHT 23'-6"

T.O. UPPER PARAPET

OVERALL HEIGHT 25'-6"

T.O. UPPER PARAPET

LINE OF FINISH

FLOOR- 0'-0"

DOORS & WINDOWS

HEADERS 7'-4"

SCONCE EIFS-1

BRICK

STUCCO

STUCCO

B.O. TYP CANOPY 9'-4"

B.O. MAIN ENTRY

CANOPY 10'-8"

EIFS 2REVEAL

35'-0"

LINE OF FINISH FLOOR- 0'-0"

DISCONNECT.

METER

T.O. SILL 3'-4"

OVERALL HEIGHT 23'-6"

T.O. UPPER PARAPET

OVERALL HEIGHT 25'-6"

T.O. UPPER PARAPET

DOORS & WINDOWS HEADERS 7'-4"

OVERALL HEIGHT 20'-2"

T.O. UPPER PARAPET

EIFS 2

STUCCO

EIFS-1

REVEALBRICK

BRICK

KNOX-2

FIXED

WINDOW

(TYP.)

5'-0

"

B.O. TYP CANOPY 9'-4"

B.O. MAIN ENTRY

CANOPY 10'-8"

41'-8"

EXTERIOR MATERIAL SCHEDULE

LABEL MANUFACTURER SIZE/TYPE FINISH COLOR

STOREFRONT KAWNEER IMPACT RESISTANT ANODIZED ALUMINUM

DOOR - PER DOOR SCHEDULE FACTORY PRIMED

FIXED WINDOW KAWNEER PER WINDOW SCHEDULE ANODIZED ALUMINUM

STUCCO SMOOTH FINISH SW 7504 KEYSTONE GRAY

BRICK VENEER THIN BRICK BY WATSONTOWN MANHATTAN SERIES "WHITE"

EIFS CORNICE & TRIM SMOOTH FINISH SW 7570 EGRET WHITE

EIFS WATER TABLE ROUGH FINISH SW 7504 KEYSTONE GRAY

COVERED ENTRY CANOPY ALUMINUM POWDER COATED ALUMINUM

BAHAMA CANOPY ALUMINUM POWDER COATED ALUMINUM

SERGE FERRARI FABRIC SOLTIS PROOF 502 BLACK

1" PVC REVEAL --- WHITE

PVC STUCCO CONTROL --- WHITE

KNOX BOX 3200 SERIES W/ RECESSED COLOR: DARK BRONZE

(MAIN ENTRY) MOUNT FLANGE, HINGE DOOR, (REF. NOTE 2 BELOW)

& TAMPER SWITCH

KNOX BOX 1650 SERIES W/ RECESSED COLOR: DARK BRONZE

(MECHANICAL ROOM) MOUNT FLANGE, HINGE DOOR, (REF. NOTE 2 BELOW)

& TAMPER SWITCH

ADDRESS 6" NUMBERS ON 1" STANDOFFS BLACK

FINISH SCHEDULE NOTES:

1. G.C. SHALL VERIFY KNOX BOX MODEL(S) AND LOCATION(S) WITH AUTHORITY HAVING JURISDICTION PRIOR TO

ORDERING/INSTALLATION.

2. G.C. SHALL ENSURE ALL EXTERIOR FINISHES ARE INSTALLED AND FINISHED IN COMPLIANCE WITH

MANUFACTURERS' WARRANTY REQUIREMENTS.

STUCCO

ENTRY

REVEAL

SCJ

KNOX-1

KNOX-2

EIFS 1

EIFS 2

AWNING

BRICK

CANOPY

ADDRESS

CYPRESS RANCH DEVELOPMENT STANDARDS

ARCHITECTURAL STANDARDS (SECTION 4.3): BUILDING MATERIALS

1/A-051 FRONT FACADE (EXCLUDING OPENINGS):

TOTAL AREA = 3,062 S.F.

50% OF TOTAL AREA = 1,531 S.F.

BRICK AREA = 1,904 S.F.

STUCCO/EIFS AREA = 1,158 S.F.

2/A-051 REAR FACADE (EXCLUDING OPENINGS):

TOTAL AREA = 2,670 S.F.

50% OF TOTAL AREA = 1,335 S.F.

BRICK AREA = 1,492 S.F.

STUCCO/EIFS AREA = 1,178 S.F.

3/A-051 SIDE FACADE (EXCLUDING OPENINGS):

TOTAL AREA = 1,396 S.F.

50% OF TOTAL AREA = 698 S.F.

BRICK AREA = 715 S.F.

STUCCO/EIFS AREA = 581 S.F.

4/A-051 SIDE FACADE (EXCLUDING OPENINGS):

TOTAL AREA = 1,307 S.F.

50% OF TOTAL AREA = 654 S.F.

BRICK AREA = 767 S.F.

STUCCO/EIFS AREA = 540 S.F.

P:\1

90

47

_T

LE

L

AN

D O

L

AK

ES

\D

RA

WIN

GS

\9

9_

TL

E_

LA

ND

OL

AK

ES

_A

RC

H\2

01

9.Q

1.0

1 G

EN

P

RO

TO

TY

PE

-A

-0

51

- C

OL

OR

.D

WG

K

EL

SI P

LO

TT

ED

: 1

2/2

7/2

01

9

1. CONTRACTOR SHALL SUPERVISE AND DIRECT

THE WORK USING THE CONTRACTOR'S BEST

SKILL AND ATTENTION. THE CONTRACTOR SHALL

BE SOLELY RESPONSIBLE AND HAVE CONTROL

OVER CONSTRUCTION MEANS, METHODS

TECHNIQUES, SEQUENCE, AND JOB SITE SAFETY

2. GC MUST PROVIDE & INSTALL ALL PRODUCTS

PER PLANS. ONLY SUBSTITUTED PRODUCTS

NEED TO BE SUBMITTED TO THE ARCHITECT FOR

APPROVAL. UNAPPROVED SUBSTITUTIONS WILL

BE REPLACED AT THE EXPENSE OF THE GC.

3. VERBAL REPRESENTATION HAS NO VALUE AND

ALL REQUESTS TO CHANGE ANY PRODUCTS OR

SPECIFICATIONS PER PLANS, MUST BE

SUBMITTED IN WRITING TO THE ARCHITECT & TLE

FOR APPROVAL.

2019.Q1.01 GEN PROTOTYPE

NO. DATE DESCRIPTION INT.

REVISION

NO. DATE DESCRIPTION INT.

ISSUE

Drawing Number:

Drawing Name:

Scale:

AS NOTED

Project Number:

19047

Drawn By:

Approved By:

---

AC

AD

EM

Y O

F E

AR

LY

E

DU

CA

TIO

N

PROFESSIONAL CERTIFICATION

NAME OF LICENSEE: STEVEN VINCI

LICENSE NUMBER: AR0017036

EXPIRATION DATE: 2/28/21

FL

-564 &

B

AL

LE

NT

RA

E B

LV

D. A

T

LA

ND

O

' L

AK

ES

PA

SC

O C

OU

NT

Y, F

LO

RID

A

6699

13t

h A

venu

e N

orth

, Sui

te 4

AS

t. P

eter

sbur

g, F

L 33

710

(727

) 38

1-52

20(7

27)

381-

0052

fax

Conceptual Site Plan1 10/28/19

Schematic Design2 12/26/19

EXTERIOR

ELEVATIONS

A-051

SCALE:

1

FRONT ELEVATION

1/8"=1'-0"

SCALE:

2

REAR ELEVATION

1/8"=1'-0"

SCALE:

3

SIDE ELEVATION

1/8"=1'-0"

SCALE:

4

SIDE ELEVATION

1/8"=1'-0"

KT | SV

AutoCAD SHX Text
1
AutoCAD SHX Text
A-061
AutoCAD SHX Text
A-141
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
A-071
AutoCAD SHX Text
1
AutoCAD SHX Text
A-061
AutoCAD SHX Text
1
AutoCAD SHX Text
A-071
AutoCAD SHX Text
2
AutoCAD SHX Text
A-061
AutoCAD SHX Text
2
AutoCAD SHX Text
A-061
AutoCAD SHX Text
B
AutoCAD SHX Text
u
AutoCAD SHX Text
b
AutoCAD SHX Text
b
AutoCAD SHX Text
l
AutoCAD SHX Text
e
AutoCAD SHX Text
s

Recommended