1312
2200 NW 32ND ST. POMPANO BEACH, FL 33069 TOLL FREE (800) 659-5843 • FAX (954) 933-3473
X T R E M E • P O L I S H I N G • S Y S T E M S
Product Code* ConcGenie
3 I N 1• G R I N D E R• E D G E R• POLISHER
F L O O R • G R I N D I N G • M A C H I N E
C O N C R E T E G E N I E
1
This book has important information for use and safe operation of this machine. Failure to read this book prior to operating or attempting any service or maintenance procedure to your Concrete Genie could result in injury to you or other personnel, Damage to the machine or to other property could occur as well. You must have training in the operation of this machine before using it. If your operator(s) cannot read this manual, please have it explained fully before attempting to operate this machine. All directions given in this manual are as seen from the operator’s position at the rear of the machine.
Floor Grinding Machine Instructions
Contents
Operators Safety Instructions .......................... ...........................1-2
Machine Instructions .............................................. ...........................11
Inverter Programing ................................................ ...........................3
Cable Connection ..................................................... ...........................5
Attaching Metals & Pads ..................................... ...........................6
Electrical Diagram .................................................... ...........................7
Handling Instructions ............................................ ..........................9
Control Panel ................................................................ .........................8
Specifications ............................................................... .........................11
Trouble Shooting ....................................................... ........................11-12
Before Operation when receiving the machine:
1. When the machine is received, carefully inspect parking and if damage is evident. Keep the shipping carton so that it can be inspected.
2. If damage is indicated contact the freight company and Xtreme Polishing Systems, Customer Service Department.
3. Unlock the power cord and connect to a suitable power outlet.
4. Attach grinding metals and polishing pads as needed.
*This manual subject to change without notice.
Manual - Concrete Genie
www.facebook.com/xtremepolishingsystemswww.youtube.com/user/XtremePol ishing
2 2 0 0 N W 3 2 n d S t . # 7 0 0
P o m p a n o B e a c h , F L 3 3 0 6 9
(866 )812-9319www.xtremepolishingsystems.com
AN AMERICAN GRINDER COMPANY
32
DANGER MEANS:Severe bodily or death can occur to you or other personnel if the DANGER statements found on this machine or in this Owner’s Manual are ignored or are not adhered to. Read and observe all DANGER statements found in this Owner’s Manual and on your machine.
WARNING MEANS:Injury can occur to you or to other personnel if the WARNING statements found on your machine or in this Owner’s Manual are ignored or are not adhered to. Read and observe all WARNING Statements found in this Owner’s Manual and on your machine.
CAUTION MEANS:| Damage can occur to the machine or other property if the CAUTION statements found on your machine or in this Owner’s manual are ignored or not adhered to. Read and observe all CAUTION statements found in this Owner’s Manual and on your machine.
DANGER
1. Failure to read the Owner’s manual prior to operating or attempting any service or maintenance procedure to your machine could result in injury to you or other personnel; damage to the machine or to other property could occur as well. You must have training in the operation of this machine before using it. If your operator(s) can not read English, have this manual ex-plained fully before attempting to operate this machine.
2. To reduce the risk of fire, use only commercially available detergent intended for machine application. Do not use with flam-mable liquids.
3. Risk of explosion. Floor sanding can result in an explosive mixture of fine dust and air. To reduce risk of explosion, use floor sanding machine only in well ventilated area.
4. Operating a machine that is not completely or fully assembled could result in injury or property damage. Do not operate this machine until it is completely assembled. Inspect the machine before operation.
5. Electrocution could occur if maintenance and repairs are performed on a unit that is not disconnected from the power source. Disconnect the power supply before attempting any maintenance or service. Always remove the electrical plug from the electrical outlet before changing the brush, pad or other attachment and before leaving the machine.
6. Using a machine with a damaged power supply cord could result in an electrocution. Do not use the machine if the power supply cord is damaged. Do not use the electrical cord to move the machine.
7. Maintenance and repairs performed by unauthorized personnel could result in damage or injury. Maintenance and repairs must be performed by authorized personnel only. Keep all fasteners tight, Keep adjustments according to specifications.
8. Electrical components of this machine can”short-cut” if exposed to water or moisture. Keep the electrical components of the machine dry. Wipe the machine down after each use. For storage, keep th machine in dry building.
9. Always use a four core electrical system connected to the electrical ground. For maximum protection against electric shock, use a circuit that is protected by a ground fault interrupter. Consult your electrical contractor.
10. To prevent damage to the power supply cord, do not let the pads, pad holders or wheels touch the power supply cord when the machine is running Always lift the cord over the machine. Do not pull the power supply cord to move the machine.
WARNING
1. Operating a machine without observing all labels and instruction could result in injury or damage. Read all machine labels before attempting to operate. Make sure all of the labels and instructional information are attached or fastened to the ma-chine. Get replacement and decals from your authorized distributor.
2. Use of this machine as a stair or furniture could result in injury or damage. Do not sit on the machine.
3. To prevent accidental injury, place your hands, feet and loose clothing away from moving parts of machine.
4. Injury to operator or bystanders could occur in an abrupt change in floor surface texture is encountered when using this machine. Abrupt change in floor surface can cause a sudden pulling motion by this machine. This sudden pulling motion can result in loss of control of the machine which could injure the operator or bystanders. Avoid motions that could allow the machine to come in contact with low obstacles, such as floor electrical outlets, door stops or entry molding, etc.
5. Water solutions or grinding and polishing materials used with the machine if adopting wet polishing can leave wet areas on the floor surface. These areas can cause dangerous condition for the operator or other persons. Always put CAUTION signs near the area being.
6. Any alterations or modifications of this machine could result in damage to the machine or injury to the operator or other bystanders. Alterations or modifications not authorized by the Manufacturer voids any and all warranties and liabilities.
NOTE
1. The machine is heavy. Get assistance before attempting to transport or move it.
2. This appliance is not suitable picking up hazardous dust.
3. This machine is intended for commercial
Manual - Concrete Genie
3
Parameter Description Function, Scope Original Data
E-01 Controlway
0. Keyboard Control1. Terminal Control2. RS485 COM Port Control
0
E-02Frequency givenselection
0. Keyboard Number Setting1. Keyboard Potentiometer2. Voltage signal or terminal VS1
1
E-13 Speedup Time 0.1-6500.0 second 30
E-18 Rotation Speed
0.1% - 25% 3
E-64 Parameter format
0. Without operation1. Restore original setting2. Remove malfunction recording
0
Setting Data
1
2
20
Concrete 12-15Marble 10-12Granite 8-10
E-34 Stop Mode
0. Deceleration stop motor1. Stop motor at once 0 1
E-63Parameter change protection
0. All parameters changeable1. Keyboard number settings changeable2. All parameters prohibit changeable
0 2
Parameter Input Resetting
1. Unlock firstly, resume original settingPress PRG, press “<<” key, adjust to E-64 on the first line of LED screen, press SET key, adjust to 1 (restore Original Setting), press SET key again.
2. Press “<<” key, adjust to E-63, press SET key, the second line of LED screen flashing, adjust to 0 (all parameter can be changeable), press SET key again.
3. The first line of LED screen shows E-63, press “<<” key, adjust to E-34, press SET key again, the second line of LED screen flashing, adjust to 1, press SET key again.
4. The first line of LED screen shows E-34, press “<<” key, adjust to E-18, press SET key again, the second line of LED screen flashing, adjust to 12-15 for concrete, 10-12 for marble, 8-10 for granite, press SET key again.
5. The first line of LED screen shows E-18, press “<<” key, adjust to E-02, press SET key, the second line of LED screen flashing, adjust to 2, press SET key again.
6. The first line of LED screen shows E-02, press “<<” key. adjust to E-01, press SET key, the second line of LED screen flashing, adjust to 1 (Terminal control such as buttons), change number to 0 (control panel keyboard control), press SET key again.
Function Code Form
Inverter Programming A 2T-2
Note: If terminal buttons are broken, change number to 0 and the machine can be operated by control panel keyboard.
Manual - Concrete Genie
54
Fault Code Fault Type Possible Fault Reason Troubleshooting
S.C. SystemFault
1. Acceleration time is set too short2. Frequency inverter output phase of
grounding short circuit3. Module failure4. Disturbance
1. Lengthen acceleration time2. Check the peripheral device, reset after
troubleshooting.3. Ask for technical support4. Check peripheral device, grounding line, shield line
grounding condition, distance condition of terminals and control motor.
O..L.1 MotorOverload
1. V/F curve setup or torque boost is not suitable
2. Network voltage is relatively low3. Motor overload protection parameter is set
improperly4. Motor block rotor operation or heavy duty load5. Universal motor low speed with heavy load
works for a long time
1. Reset V/F curve or torque boost value2. Check the input power3. Check [E-67] setting4. Adjust load or select and use frequency inverter with
matching capacity grade5. When requiring long term low speed work, please use
special motor for frequency inverter
O.L.2Frequency InverterOverload
1. Heavy Load2. Acc time is set too short3. Restart the motor in running when momentary
stop occurs4. V/F curve setup or torque boost is not suitable
1. Select frequency inverter with proper capacity2. Lengthen acceleration time3. Restart after the motor completely stop or set [E-30]
as “2”4. Reset V/F curve or torque boost value
O.H.FrequencyInverterOverheat
1. Too High ambient temperature2. Damaged fan3. Blocked air duct4. Carry wave frequency is too big
1. Ameliorate periphery environment2. Replace fan3. Clear air duct, improve the frequency inverter
periphery ventilation and dissipation environment4. Check [E-20] and [E-21] setting
LU2
Over Voltage of supply power at running
1. Supply power is too low2. Capacity of power network is too small or
instantaneous surge current inside power network is too big
3. DC main contactor inside the frequency inverter not close
1. Check the supply voltage and troubleshooting2. Improve power supply system3. Ask for technical support
Inverter B type
Inverter B type
Fault Code
Fault Type
Possible Fault Reason
Troubleshooting
S.C. SystemFault
1. Acceleration time is set too short2. Frequency inverter output phase of grounding
short circuit3. Module failure4. Disturbance
1. Lengthen acceleration time2. Check the peripheral device, reset after
troubleshooting.3. Ask for technical support4. Check peripheral device, grounding line, shield line
grounding condition, distance condition of terminals and control motor.
O..L.1 MotorOverload
1. V/F curve setup or torque boost is not suitable
2. Network voltage is relatively low3. Motor overload protection parameter is set
improperly4. Motor block rotor operation or heavy duty load5. Universal motor low speed with heavy load
works for a long time
1. Reset V/F curve or torque boost value2. Check the input power3. Check [E-67] setting4. Adjust load or select and use frequency inverter with
matching capacity grade5. When requiring long term low speed work, please use
special motor for frequency inverter
O.L.2Frequency InverterOverload
1. Heavy Load2. Acc time is set too short3. Restart the motor in running when momentary
stop occurs4. V/F curve setup or torque boost is not suitable
1. Select frequency inverter with proper capacity2. Lengthen acceleration time3. Restart after the motor completely stop or set [E-30]
as “2”4. Reset V/F curve or torque boost value
O.H.FrequencyInverterOverheat
1. Too High ambient temperature2. Damaged fan3. Blocked air duct4. Carry wave frequency is too big
1. Ameliorate periphery environment2. Replace fan3. Clear air duct, improve the frequency inverter periph-
ery ventilation and dissipation environment4. Check [E-20] and [E-21] setting
LU2
Over Voltage of supply power at running
1. Supply power is too low2. Capacity of power network is too small or
instantaneous surge current inside power network is too big
3. DC main contactor inside the frequency inverter not close
1. Check the supply voltage and troubleshooting2. Improve power supply system3. Ask for technical support
Manual - Concrete Genie
5
Xtreme Hard Densifier
Number 1 Brand for Hardening, Protecting & Cleaning Concrete Floors
Xtreme Hard is a highly reactive Colloidal Silica-based densifying agent. The Colloidal Silica molecule has more reactive sites, so it goes
to work quickly, within 1-2 minutes. Spray it on the concrete until the surface is saturated, then agitate with a soft bristle broom. Wait until
dry (45-60mins). Xtreme Hard is a green, clean and safe material. Its low pH formula (pH approx 8.7, only slightly higher than baking soda)
is safer for you to handle. Xtreme Hard emits no Volatile Organic Compounds (VOCs) and eliminates the hazardous-material dispos-
al, so it’s better for the job site and friendlier to the planet. Xtreme Hard is shipped as a concentrate. One gallon of concentrate makes five
gallons of ready-to-use product. Xtreme Hard is the lowest cost densifier per square foot. New Improved Nano Technology Formula,
penetrates deeper into the concrete. (Mix 1 part Hard to 4 parts potable water)
*Up-graded ~ XPS Magnetic Plates Installed
Attaching Grinding & Polishing Tools to Genie Magnetic Plates
1. Round Metals & Traps easily snap in place and stay locked due to magnets
2. To remove use a thin blade flat screwdriver place in slot between segment and plate and push outward.
Attaching Diamond Polishing Pads, Velcro Backed
1. Snap Velcro backed spacers (Hockey Pucks) onto plates, magnets hold in place
2. Attach Velcro backed diamond resin pads on top of spacer. The Velcro locks the pads in place. To change simply peal off old pad and
place new pad on spacer.
Adapter Hockey PuckFor Attaching Pads & Resins
Tools on magnetic plate, simply snap on,and snap off
All Concrete Genies equipped with MorFlex couplers for even floor grinding
XPS Magnetic PlatesFor Quick Tool Changes
From Slabs to Malls, it works for all.
• Offices
• Schools
• Factories
• Residences
• Warehouses
• Shopping Malls
Easy to Apply On Concrete Floors:
• Low Maintenance
• Fortifies Concrete Floors
• Stops Dusting
• Reduces Energy Cost
• Wear Resistance
• Improves Traction
• Eliminates Mold
• LEED Compliant
Coverage: 400-600 square feet per gallon of working solution.
Xtreme Polishing Systems
76
Parameter Input Resetting
1. Unlock Press PRG, NO. 00000 showing , then press SET, change the number to 12345 (from left to right), then press SET again, PO will show
on screen.
2. Restore Factory Settings Press SET, P0.00 showing, change it to P0.17, press SET, change the number to 1, then press SET, P0.00 should show on the screen.
3. Speed Control Mode Chosen (changed) Press SET, choose the number to 0 under P0.00 item, then press SET, P0.00 showing again
4. Operation Instruction Channel Change P0.00 to P0.01, press SET, then change the number to 1, press SET again, PO.02 showing
5. Hz Setting Change P0.02 to P0.03, press SET, then change the number to 60Hz, press SET again, PO.04 showing
6. Frequency Channel Change P0.04 to P0.07, press SET, then change the number to 2, press SET again, PO.08 showing
7. Acceleration Time Change P0.08 to P0.11, press SET, then change the number to 0030.0, press SET again, PO.12 showing
8. Stop Manner Press PRG once, P0 showing on the screen, change to P1. Press SET, P1.00 showing, change to P1.06. Press SET,
change the number to 1, then press SET, P1.07 showing.
9. Terminal Choose Press PGR once, P1 showing on the screen, change to P5, press SET, P5.00 showing, change to P5.01. Press SET, change the number to 1, press
SET, P5.02 showing. Press SET, change the number to 2, Press SET, P5.01 showing.
10. Torque Boost.Press PGR, P5 showing on the screen, change to P4, press SET, P4.00 showing, change to P4.01, press SET, then set the number to 3..Press SET, P4.02 showing, *Note: if set number 3 under P4.01 item, the machine cannot back normal, please try to number 2, the point under item P4.01 can change from 1-9.
11. Locking Change P5.03 to P5.01, press PRG, showing P5 change to P7, press SET, P7.00 showing, press SET, 00000 showing, change it to
12345 (left to right) press SET, P7.01 showing.
12. Final Press PRG two times.
Cable Connection
Note:
1. Machine electrical system must be in strict accordance with parameters marked on the plate (voltage, frequency), Before connected to the input supply. Ensure the input power supply voltage and frequency comply with voltage a
2. Machine must be connected to the power systems which have grounding connection to prevent the operator of electrical shock. 3. The machine (3 phase) power cord with three leading cable and ground wire. The plug must be connected to a suitable outlet. Green, yellow
stripes wire is ground wire which is strictly prohibited to connect to the non-socket.
Warning:
1. Plug must be connected2. Make sure the power plug is connected3. Three phase voltage4. To use an extension cord5. Prohibit removing, cutting or damaging
Connection Way:
1. One phase power connect terminal R, T; Three phase power connection R, S, T terminals, and pay attention to the machine model.2. Terminal U, V, W connect motor3. Potentiometer connects VCC, VIN, GDN terminals.
Manual - Concrete Genie
7
Recessed indicator lights
Reset button
Emergency stop button
On ~ Off Switch
On (left) ~ tools spin counter clock wise
* Important
When running PCDs, check cor-rect rotation for each type of PCD
* NoteIf computer error is indicated on panel, press reset button only! This resets computer to original setting
On (right) ~ tools spin clock wise
RPM & FAULT display
Variable speed dial 0-1500 rpm
Adjustable handle release
Computer digital display
*Computer pre-set at factory( do not re-program )
*Machine runs best at1300 to 1500 rpm
2T Series Introduction (picture 1)
WARNING: Machine has rotation parts, ensure power off before any maintenance service to avoid damage and or injury.
2T Structure Item Description1. Handle
2. Control Panel
3. Handle Adjuster
4. Veer/Halt Switch
5. Operating Light
6. Power Light
7. Socket
8. Handle Axes
9. Side Arm
10. Water Controller
11. Motor Cover
12. Place for Weight Iron
13. Inlet of Water Tank
14. Water Tank
15. Gear Box Base
16. Lever Sheath
17. Pad Holder
18. Clip
19. Level Adjuster
20. Motor Fix Crew
21. Motor
22. Level Measurer
23. Belt Tighten Screw
(1)(3)(6)
(10)
(11)
(12)
(13)
(14)
(16) (15)
(9)
(8)
(7)(5)(4)
(2)
Manual - Concrete Genie
98
*Up-grated ~ XPS Magnetic Plates Installed
Do Not accept imitations: Use only genuine XPS MAGNETIC PLATES
Xtreme Diamond Polishing Pads
Xtreme Resin Pads
Xtreme Ceramic Pads
Metal Bond Diamonds - 6 seg
Metal Bond Diamonds - 8 seg
Metal Bond Diamonds - 10 seg
PCD
Diamond Traps
For best results use genuine
XPS resin pads
For best results use genuine
XPS round metals or traps
For best results use genuine
XPS round metals or traps
Electrical Diagram
2T-1 Electrical Diagram
Electrical Diagram
2T-2/2T-3/3T-420/3T-530/4P12T-40 Connection Sketch
Note: Power entering lines must be equipped with residua; current
circuit-braker
pic (33)
1. Speed Adjuster
2. Veer/reverse rotate button
3. Emergency stop button
4. Motor
5. Operation light
6. Power light
pic (34)
GREEN
GREEN
Xtreme Polishing Systems
9
Adjust the handle position (for 2T series)
1. Pull handle adjuster as picture (8), adjust handle to suitable position and release handle adjuster, the handle will be locked up as picture (9)
2. Grip handle to operate machine
Water Controller
1. Ensure water controller is off before water injection as picture (10), counterclockwise rotation is off, clockwise rotation is opening the water controller
2. Input water as picture (11)
3. Adjust the water amount according to operation requirements
Warning
Before motor starts, do prepare control of the machine, after start the machine, move the machine back and forth or right and left toavoid damaging the floor
Note
1. During operation, be careful of the pads wearing condition to change pads in time if the pads wearing out.
2. Take off the weight iron if grinding soft surface otherwise will speed up the wearing pads
3. After operation, remove convertible adaptors and keep in fry place to avoid damage
Change the diamond pad
Tip over the machine as picture (3), and (4)
pic (8)
pic (11)
pic (9)
pic (10)
pic (3)
Manual - Concrete Genie
Pad holder rotation
pic (6)
Change the diamond pad
Change diamond pads
pic (5)
Multi-functional under prop
pic (7)
Move the machine
Insert lever sheath, adjust handle to
horizontal position, and lift machine.
pic (2) pic (3)
1110
Specification may be amended without notice
• Description..................................................Concrete Genie (2T-2)
• Voltage............................................................220V - 1Ph
• Working width..........................................560mm - 22 inch
• Sweep..............................................................635mm - 25 inch
• Rotation speed (Rpm)........................0-1500
Troubleshooting
MACHINE INSTRUCTIONThe Genie Series are floor maintaining machines that can be used for grinding, polishing, buffing and stripping.
The machines can be used on concrete, terrazzo, marble, granite, wood or vinyl floors. With the suitable pad, the
machines can be used to remove epoxy on the floor. The machine is suitable for industrial and commercial use for
example in hotels, schools, hospitals, factories, shops, offices and rental businesses
ACCESSORIES (OPTIONAL)1. Adaptor––used for renovating and polishing stone
2. Metal adaptor A––used for grinding concrete floor and epoxy flooring.
3. Metal adaptor B (strong magnet)––used for grinding concrete floor, epoxy flooring and stone surface
4. Waterproof cover
5. Waterproof plug
6. Metal segments (Diamond alloy segments)
7. Concrete grinding pad
8. Stone grinding pad
9. Extended cable
10. Distribution box
11. Lever
WARNING: Use only accessories supplied by the manufacturer.
• Transmission....................................................Gear
• Power (HP).........................................................belt 5.5
• Power cord (mt).............................................15
• Water tank..........................................................36L - 9.5 gal
• Weight...................................................................165Kg - 363 lbs
Working Width (mm) 560 580’580
Model Description 2T-1 4P16T-580
Voltage (V/Hz) 3 phase 3 phase
560
2T-2
1 phase
Power (HP) 5.5 / 7.5 15
Rotation Speed (Rpm) 900 0-1500
Transmission gear belt gear
5.5 / 7.6
0-1500
gear belt
Weight (KG) 165 350
Power Cord (mt) 15 15
Water Tank (L) 36 45
165
15
36
480’480
4P12T-480
3 phase
7.5 / 10
0-1500
gear
210
15
35
560
2T-3
3 phase
5.5 / 7.7
0-1500
gear belt
165
15
36
420
3TX-420
1 phase
5.5
0-1500
two stage planetary gear box
135
15
35
530
3TX-530
1/3 phase
5.5 / 7.5
0-1500
two stage planetary gear box
180
15
35
680’680
4P16T-680
3 phase
20
0-1500
gear
430
15
45
Manual - Concrete Genie
SPECIFICATIONS
11
Troubleshooting
SWIRLS ON THE FLOOR AFTER GRINDING• Moving the machine too fast or machine stay still too long
• Adopt inappropriate pad
SCRATCH ON THE FLOOR• Machine standing still while the pad is running
• Grinding method is not correct
• Adopt inappropriate pad
• Incorrect operation
MACHINE WOBBLES DURING OPERATION• Check ground level is very serious or not, if level difference is very serious (2mm above). First with the angle
grinder machine repair, and then grinding slowly from high place to lower place with constant speed and
shape moving
• Check the pad holders is loose or not, whether in the same level
• Check adopting same pads or not
• Check pads are in same level or not
• Adjust connector between machine frame and machine base, keep the pad holders and wheels in the same
level
SUDDENLY STOP RUNNING (OVER CURRENT PROTECTION)• Tap the STOP button, Tap RUN button after 5 seconds to restart. Gently press the handle when restarting to
make pad holder smaller friction, which will restart easier.
PAD• Remove iron weight
• Adjust machine frame, keep the pad holders and wheels in the same level
MACHINE CANNOT RUN• Check plug for proper connection––on machine and at wall outlet
• Check building circuit breaker
• Call for Mendel service center or distributor
Err 6 Keyboardcommunicationfault
1. Check the keyboard wiring 2. Ask for technical support
Err 1 Open-phase at input side
Check three phase input power and three phase input power wiring
Err 2 Output grounding
Check peripheral device, grounding line, motor insulation
1. Keyboard wiring fault 2. Keyboard communication component damaged
Open-phase in frequency inverter three phase input power phase
Frequency inverter has device grounding short circuit at the output side
Manual - Concrete Genie
13
AN AMERICAN GRINDER COMPANY
X T R E M E • P O L I S H I N G • S Y S T E M S
www.facebook.com/xtremepolishingsystemswww.youtube.com/user/XtremePol ishing
2 2 0 0 N W 3 2 n d S t . # 7 0 0
P o m p a n o B e a c h , F L 3 3 0 6 9
(866 )812-9319www.xtremepolishingsystems.com