1
Condensate Safety Awareness
02/25/2015PIOGA Winter Meeting
Wayne Vanderhoof CSP
“Working Safe, Preventing Injuries, Protecting Profi ts”
RJR Safety Inc.
Incidents
• Jan. 11, 2014• Cabot Oil & Gas• Susquehanna County
– “vapors in the headspace of a wastewater tank ignited”
– “worker checking the level…using his cellphone as a flashlight”
– Unknown on injuries
• July 7, 2013• Antero Resources• New Milton, WV
– “build-up of gas from tanks used to store flow-back water”
– “were not measuring for flammable gas levels in the area”
– Ignition source unknown
– 2 workers killed 2
Incidents
• Nov. 12, 2014• Blue Racer (midstream)
– Noble County OH– Explosion when
working on a pump that moves condensate
– Would have been testing & calibrating electrical components on the pump
– 1 person killed
• Oct. 28, 2014• Blue Racer (midstream)
– Monroe County, OH– Pipeline ruptured &
caught fire– Carrying natural gas-
condensate to processing plant in WV
– No injuries, evacuations, & brush fires 3
Incidents
• Oct. 27, 2013• Antero Resources
Doddridge County WV– “condensate was
released…vapors were ignited by a nearby heater”
– “workers installing floats on…production tanks”
– 2 workers injured
• Between 2012 to 2014– Specific date unknown
• Injection Well in OH– Fire in the sump– Minor damage except
for multitude of fire extinguishers
– Condensate on top of the water in the sump/drain area at the rear of the truck 4
Incidents
• March 31, 2010• Atlas Resources
– “spark ignited condensate vapors in a pit” and flames spread into water tanks of flow-back water
– “Malfunction ignited the flames”
– At least 1 worker injured
• During the investigation– “other well sites…had
condensate storage…with vapors escaping…”
5
Why Discuss Now?
• Number of incidents increasing– Deaths, injuries, & property damage,
environmental incidents
• NGL production increases so goes condensate production
• Unconventional well condensate hazards are very different from conventional wells– Appears not a realization or consideration
• Hazard is recognized now has to be eliminated or otherwise controlled
6
Objective• Make you aware of the hazards of
Condensate• Begin the process of developing
methods to control the hazards• Better able to protect workers from the
hazards
7
• Agenda– Describe Condensate– Identify the Hazards– Discuss methods to control the hazards
How does it get there?• Gas cools as it comes up the wellbore
forming liquid called condensate• Flow-back water from a well
– Stored in “frac” tanks/Re-used for next “frac”
• Produced water used for hydraulic fracturing
• Water is transferred using vacuum trucks– Transfer between sites, locations
• Varies in quantity of condensate
• Pipelines– More in the winter due to cooling
10
Wet Gas NGL Condensate
11
ComponentsCarbon Molecules
Methane C1
Ethane C2
Propane C3
Butane C4
Pentane C5
Hexane C6
Heptane C7
Octane C8
Other Hydrocarbon Molecules (Light liquids)
C9-C10
Crude oil (Heavy liquids)(Parafins, Naphthenes, Aromatics, Asphaltics)
C11 to C20
• Non-energy Components– Nitrogen– Carbon Dioxide– Hydrogen Sulfide*– Helium– Toluene– Benzene
Condensate (light)
12
Specific Gravity API Gravity
Condensates, Natural Gas Liquids
(NGL),& Natural Gas
0.30 to 0.70 340 to 71 Degrees
Crude Oil 0.76 to 1.03 55 to 6 Degrees
Water 1 10 Degrees
13
Natural Gas Liquids (NGL) & Condensate
Water:• Clear -produced• Dirty – Frac flow back• Creamy – flow back• Combination
Many Names
• Natural gas liquids (NGL)
• Natural gas condensate
• Hydrocarbon condensate
• Y- grade
• Lease Condensate• Gas condensate• Drip gas• Field condensate• Pipeline liquids• Natural Gasoline
14
• Condensates are not:– Liquefied natural gas (LNG)– Liquefied Petroleum Gas (LPG) (Propane mix)
Highly Flammable
• Condensate is Flammable (extremely)– Flash fire hazard– Flashpoint (FP) range of -211o F to -100o F
• Gasoline has FP of -45o F
16
Lighter than Water• Condensate floats on top of water
– Specific Gravity of less than 1• Lighter than water
17
Solubility & Evaporation
• Not water-soluble– Does not mix easily with the water
• Unless stirred with agitator continuously• Stirring stops and separation will begin
• Evaporates Easily– The higher the vapor pressure the greater the
tendency for the liquid to evaporate• Turns from liquid to vapor• Vapors become airborne easily• Accumulates quickly to LEL (potential)
18
Heavier than Air
• NGL has Vapor Density slightly greater than 1– Gathers in low places (heavier than air)
• Condensate floats on top of water and the vapors stay close to the top of the condensate– Does not rise easily– Depends on the heat inside the tank
• Hotter air will make it rise (expand) more easily– Makes it “lighter” than air 19
Health Hazards
• Flammable gases– Asphyxiant (Suffocation)
• Reduces the amount of oxygen available
• Carcinogen– Benzene only
• Mostly present in crude oil• Small amounts (less than 1%) in natural gas
liquids• OSHA PEL 1ppm
– 29CFR1910.1028 Benzene standard20
Hazard Control Order
• Eliminate the hazards– Cannot be eliminated to 100%
• Control the hazards• Protect the workers
22
Hazard: Highly Flammable
• Ignition sources– Static electricity– Electricity
• Eliminate arcs
• Electrically-rated equipment
– Heat• Hot surfaces
• Flames
• Hot work
• Control methods– Bonding & grounding– Proper equipment
• Non-arcing equipment
• Explosion-proof
• Intrinsically safe
– Eliminate/Control heat sources
• Hot Work Permit
• Cell phones
• Digital cameras
• Flashlights
– Fire Extinguishing Equipment23
Static Electricity• Created by friction and the movement of
materials in tanks & flow in pipe
• Controlling static electricity• Provide a path (Bonding & Grounding)• Eliminate the spark!
24Ground
++++++
Zero chargeStatic Charge
++++++
Grounding
• Grounding connects one or more conductive objects directly to the earth. Unlike bonding, proper grounding does drain static charges.
25
Ground
+++ +++
Bond Wire
Eliminates static charge
++++++
Frac Tank Protection
27
Compliments:Lightning Master® in-tank static drain (ITSD)
Static DissipatorSystem
Eliminate Heat Sources• Smoking in designated areas• Restrict running or parked vehicles
– Within 100 ft. of Wellbore or Production Tank• API RP 54 “Occupational Safety for Oil and Gas Well Drilling and
Servicing Operations”, Chapter 6 “Operations” Section 6.1.15
• Hot Work Permit• Use correct electrically-rated tools
– Intrinsically safe• Not capable of releasing sufficient electrical or
thermal energy under normal or abnormal conditions to cause ignition
• Flashlights, cameras, portable radios, cell phones 31
Hazard: Lighter than WaterHazard: Evaporates EasilyHazard: Heavier than Air
• NGL and Condensate floats on top of water– Lighter than water; Not water-soluble
• Turns from liquid to vapor & becomes airborne easily
• Vapors stay close to the top of the water– In the tank headspace– Escape upon opening of hatch 32
Hazards Control• Assume other than fresh water tanks have
condensate in/on them• Unless tested & proven otherwise
– Need to best determine testing methods
• Use LEL meter or 4-gas monitor• Personal and/or Area monitoring• When opening the hatch
• Follow tank gauging procedures• Leave 1 to 2 feet (+) of water in the tank• Fire extinguishing equipment
33
Field Testing Methods
35
Bef
ore
gaug
ing
Condensate
Afte
r ga
ugin
g• Color Cut Test• Multi-gas monitor• Manual sample
• Oxygen level– Less than 19.5%
» Asphyiation/suffocation
• Lower Explosive Limit (LEL)
• Any % indicates a flammable is present!
“Frac” Water Tanks & Tasks
37
• Gauging tanks• Visual level
check• Prep for
transport• Cleaning Containing
flow-backwater
Production & Produced Water Tanks & Tasks
38
Gauging tanks, Checking visual levels,Tank cleaning or maintenance, water transfer by truck
Other Locations & Tasks• Maintenance
– Piping• Production, gathering, transmission, and
distribution• Pipeline pigging operations
– Compressor stations– Processing equipment
40
Potential Hazards & ControlsPotential Hazards
• Highly flammable• Lighter than water• Evaporates easily• Heavier than air
Control Measures• Bonding & grounding
– Bare hand grounding
• Proper equipment use
• Eliminate/Control heat sources
• Assume other than fresh water tanks have condensate in/on them
• Use LEL meter or 4-gas monitor
• Follow tank gauging
procedures
• Do not empty tanks
• Fire extinguishing equipment
41
• Address hazards on JSA• Discuss during pre-shift
meetings• Define emergency
response actions
Engineering/Design
• Standardized facility designs• Remote monitoring• Bonding & Grounding• Ignition Source Control• Vapor control/recovery
– Closed systems
• Proper equipment design & placement– Correct per area electrical rating
42
Engineering/Design
• Condensate creates a Flash Fire hazard• Why place a worker in an environment
with a known or potential flash fire hazard?– How much potential?– Eliminate the hazard?– Engineer out the hazard?
• API RP 99 – Flash Fire Risk Assessment for the Upstream Oil & Gas Industry– April 2014 release
43
Standard Operating Procedures (SOP)• Operating Equipment• Performing tasks
– Transferring/Loading/Unloading procedures• Frac tanks/Water tanks/impoundments/Prod.
Tanks
– Gauging tanks– Cleaning tanks
• Maintenance/Repair tasks– Tanks/pumps/valves/gauges– Pigging operations– Electrical equipment 44
Safety Procedures• HAZCOM
– Understand NGL & Condensate hazards
• Hot Work– Permit/Ignition Source Control– Designated smoking areas
• Electrical Safety– Bonding & Grounding
• LEL Monitoring• PPE• Emergency Action & Response Plans
45
PPE
46
Hazards Control Methods
Flash Fire Flame-resistant Clothing
Asphyxiant/Suffocation Respiratory Protection
Carcinogenic Respiratory Protection
Now that we know about a hazard…
We are required to do something!• Analysis/Audit
– Identify areas, process, equipment, tasks, operations for potential NGL/condensate
• Develop S.O.P.s• Update/develop Safety Procedures• Train the workers• Coach & enforce the SOPs & procedures
47
If No Procedures…
• Exercise Stop Work Authority• Get your Supervisor involved• Do not proceed with Operations until
hazards have been eliminated and/or controlled and workers are protected.
48
Summary• Incidents involve potential for injuries, property
damage, environmental incidents• So long as wet gas is drilled for, we will have
Condensate & associated hazards• Discussed methods to control the hazards &
protect workers– Engineering & Design– SOPs & Safety Procedures– PPE – last resort
More information & training is needed!49
ReferencesDocument Title
API 2003 Protection against Ignitions Arising out of Static, Lightning, and Stray Currents
API 2015 Cleaning Petroleum Storage TanksAPI 2027 Ignition Hazards in Abrasive Blasting of
Atmospheric Hydrocarbon Tanks in Service
API 2219 Safe Operation of Vacuum Trucks in Petroleum Service
NFPA 30 Flammable and Combustible Liquids Code
NFPA 70 National Electrical CodeNFPA 77 Static Electricity
50
51
Questions or Comments?
Thank you!
Wayne Vanderhoof CSP
“Working Safe, Preventing Injuries, Protecting Profi ts”Email: [email protected] Cell 724-809-4234
RJR Safety Inc
Bakken Oil in N.D.
• Crude oil & natural gas & natural gas liquids coming from same wellbore– Previously separated then flared the natural
gas• Leaving the natural gas liquids (NGL)
• NGL makes the mixture more unstable– More flammable than just crude oil– Vapor pressure is higher than just crude oil
• Vapor (flammable) more easily created
52