CONFOCAL MICROSCOPY
PREPARED AND PRESENTED BY:Mahesh LamsalCentral Department Of Biotechnology, Kirtipur, Kathmandu Nepal.
25th March 2016
2
SLIDES INCLUDE
Introduction History Instrumental design Principle Working mechanism Applications Advantages Limitations References
3
INTRODUCTIONConfocal microscopy : (having the same focus )
An optical imaging technique for increasing optical resolution and contrast of a micrograph.
Radiations emitted from laser cause sample to fluoresce. Uses pinhole screen to produce high resolution images. Eliminates out of focus. So images have better contrast and are less hazy. A series of thin slices of the specimen are assembled to generate
a 3-dimensinal image. Is an updated version of fluorescence microscopy.
4
HISTORY
Two investigators at Cambridge, Brad Amos and John White attempted to look at the mitotic divisions in the first few divisions in embryos of C. elegans.
They were doing antitubulin immunofluorescence and were trying to determine the cleavage planes of the cells,
but were frustrated in their attempt in that the majority of the fluorescence they observed was out of focus.
They looked at the technique called confocal imaging which was first proposed by Nipkow and pioneered by a postdoc at Harvard named Minsky.
He made the first stage scanning confocal microscope in 1957.
By illuminating single point at a time, Minsky avoided most of the unwanted scattered light.
For builiding the image, Minsky scanned the specimen by moving the stage rather than light rays.
Marvin Minsky
5
INSTRUMENTAL DESIGN
fig: Ray diagram for confocal microscope
6fig: schematic diagram confocal microscope
7
PRINCIPLE
In confocal microscopy two pinholes are typically used:A pinhole is placed in front of the illumination source
to allow transmission only through a small areaThis illumination pinhole is imaged onto the focal
plane of the specimen, i.e. only a point of the specimen is illuminated at one time.
Fluorescence excited in this manner at the focal plane is imaged onto a confocal pinhole placed right in front of the detector.
Only fluorescence excited within the focal plane of the specimen will go through the detector pinhole.
Scanning of small sections is done and joined them together for better view.
8
WORKING MECHANISM
Confocal microscope incorporates 2 ideas: 1. Point-by-point illumination of the specimen.2. Rejection of out of focus of light. Light source of very high intensity is used—Zirconium arc lamp in
Minsky’s design & laser light source in modern design.a)Laser provides intense blue excitation light. b)The light reflects off a dichoric mirror, which directs it to an
assembly of vertically and horizontally scanning mirrors.c)These motor driven mirrors scan the laser beam across the
specimen.d) The specimen is scanned by moving the stage back & forth in the
vertical & horizontal directions and optics are kept stationary.
9
Contd….
Dye in the specimen is excited by the laser light & fluoresces. The fluorescent (green) light is descanned by the same mirrors
that are used to scan the excitation (blue) light from the laser beam
then it passes through the dichoric mirror then it is focused on to pinhole. the light passing through the pinhole is measured by the
detector such as photomultiplier tube. For visualization, detector is attached to the computer, which
builds up the image at the rate of 0.1-1 second for single image
10
APPLICATIONS
1.Confocal microscopy allows analysis of fluorescent labelled thick specimens without physical sectioning.
Fig:Zebra fish embryo wholemount Neurons (green) Cell adhesion molecule (red)
2. Three-Dimensional Reconstruction of Specimen
3D shadow projection
11
Because the images are detected by a computer rather than by eye, it is possible to detect more color differences.
3. More Colour Possibilities
12
APPLICATIONS
Fig:An Intestine Section
Fig: Kidney cells (fluorescence vs Confocal microscope
4. Improved Resolution
13
Fig: Colour coded image of actin filaments in a cancer cell
14
ADVANTAGES The specimen is everywhere illuminated axially, rather than at
different angles, thereby avoiding optical aberrations. Entire field of view is illuminated uniformly. The field of view can be made larger than that of the static
objective by controlling the amplitude of the stage movements. Image formed are of better resolution. Cells can be live or fixed. Serial optical sections can be collected. Taking a series of optical slices from different focus levels in the
specimen generates a 3D data set.
15
DRAWBACKS
Resolution : It has inherent resolution limitation due to diffraction. Maximum best resolution of confocal microscopy is typically about 200nm.
Pin hole size : Strength of optical sectioning depends on the size of the pinhole.
Intensity of the incident light Fluorophores : a)The fluorophore should tag the correct part of the
specimen. b)Fluorophore should be sensitive enough for the given
excitation wave length. c)It should not significantly alter the dynamics of the organism
in the living specimen. Photobleaching: photochemical alteration of a dye or a
fluorophore molecule such that it permanently is unable to fluoresce
16
REFERENCES Pawley JB (editor) (2006). Handbook of Biological Confocal
Microscopy (3rd ed.). Berlin: Springer. ISBN 0-387-25921-X Confocal Microscopy - The Comprehensive Explanation www.microscopyu.com Marvin Minsky (1988). "Memoir on inventing the confocal
scanning microscope". Scanning10 (4): 128–138. doi:10.1002/sca.4950100403.