Room name
101
A12.081
SIM
101a
0
1
DETAIL REFERENCE
REFERENCE LABEL WHERE OCCURES
DETAIL NUMBER
SHEET NUMBER
EARTH
GRAVEL / ROCK
CONCRETE
CONCRETE BLOCK (CMU)
SAND, GROUT, OR PLASTER
STEEL
PLYWOOD
MATERIALS REFERENCE
WOOD, CONTINUOUS MEMBER
WOOD, BLOCKING
WOOD, FINISH GRADE
SECTION REFERENCE
REFERENCE LABEL WHERE OCCURES
SECTION NUMBER
SHEET NUMBER
10"
10"
DIMENSION REFERENCE
FACE OF OBJECT
CENTER LINE OF OBJECT
CABINET TYPES
TAGS AND MARKERS
- PREFINISHED CABINETS
- PREFINISHED MOBILE CABINETS
- PREFINISHED MOVEABLE CABINETS
- PREFINISHED UTILITY CABINETS
- SCIENCE CABINETS
NOTE: REFER TO SPECIFICATIONS FOR SPECIFICCABINET TYPE REQUIREMENTS.
1
1
PLAN REFERECE GRID
REVISION MARKER
PLAN KEY NOTES
ROOM LABEL
ROOM NAME
ROOM NUMBER
WALL TYPE MARKER
DOOR ID
DOOR DESIGNATION
ROOM NUMBER
REFER TO ARCHITECTURAL FLOR PLAN SHEETS AND CONSULTANT DRAWINGS FOR ADDITIONAL SYMBOLS AND REFERENCE DESIGNATIONS
CENTER LINE
PC
PM
PR
PU
PS
1
A12.08
SIM
XX-1 FINISH TAG
XX-1 FLOOR FINISH TAG
STRUCTURAL GRID LINE
1 2016 BUILDING STANDARDS ADMINISTRATION CODE (PART 1, TITLE 24, CCR)
2 2016 CALIFORNIA BUILDING CODE (PART 2, VOLUMES 1 AND 2, TITLE 24, CCR)
3 2016 CALIFORNIA ELECTRICAL CODE (PART 3, TITLE 24, CCR)
4 2016 CALIFORNIA MECHANICAL CODE (PART 4, TITLE 24, CCR)
5 2016 CALIFORNIA PLUMBING CODE (PART 5, TITLE 24, CCR)
6 2016 CALIFORNIA ENERGY CODE (PART 6, TITLE 24, CCR)
7 2016 CALIFORNIA FIRE CODE (PART 9, TITLE 24, CCR)
8 2016 CALGREEN BUILDING STANDARDS CODE (PART 11, TITLE 24, CCR)
9 2016 CALIFORNIA REFERENCED STANDARDS CODE (PART 12, TITLE 24, CCR)
10 TITLE 19, CCR, PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS
1. A COPY OF PART 1 AND 2 CCR SHALL BE KEPT ON SITE AT ALL TIMES.2. ALL CONSTRUCTION CHANGE DOCUMENTS AND ADDENDA TO BE SIGNED BY THE ARCHITECT,
THE OWNER, AND APPROVED BY DSA. CONSTRUCTION CHANGE DOCUMENTS ARE NOT VALID UNTIL APPROVED BY DSA PER SECTION 4-338.
3. ALL TESTS TO CONFORM TO THE REQUIREMENTS OF SECTION 4-335.4. TESTS OF MATERIALS AND TESTING LABORATORY SHALL BE IN ACCORDANCE WITH SECTION
4-335.5. DSA SHALL BE NOTIFIED AT THE START OF CONSTRUCTION AND PRIOR TO PLACEMENT OF
CONCRETE PER SECTION 4-331.6. INSPECTOR SHALL BE APPROVED BY DSA. INSPECTOR SHALL BE IN ACCORDANCE WITH
SECTION 4-333(b). THE DUTY OF THE INSPECTOR SHALL BE IN ACCORDANCE WITH SECTION 4-342.
7. SUPERVISION OF CONSTRUCTION BY DSA SHALL BE IN ACCORDANCE WITH 4-334.8. CONTRACTOR, INSPECTOR, ARCHITECT, AND ENGINEERS SHALL SUBMIT VERIFIED REPORTS
(FORM 6) IN ACCORDANCE WITH SECTION 4-336 AND 4-343.9. THE ARCHITECT AND THE STRUCTURAL ENGINEERS SHALL PERFORM THEIR DUTIES IN
ACCORDANCE WITH SECTIONS 4-333(a) AND 4-341.10. THE CONTRACTOR SHALL PERFORM HIS DUTIES IN ACCORDANCE WITH SECTION 4-343.11. THE INTENT OF THE DRAWINGS AND SPECIFICATIONS IS THE (RE)CONSTRUCTION OF A SCHOOL
BUILDING(S) IN ACCORDANCE WITH TITLE 24, C.C.R. SHOULD ANY CONDITIONS DEVELOP NOT COVERED BY THE CONTRACT DOCUMENTS WHEREIN THE FINISHED WORK WILL NOT COMPLY WITH SAID C.C.R. A CONSTRUCTION CHANGE DOCUMENT DETAILING AND SPECIFYING THE REQUIRED WORK SHALL BE SUBMITTED AND APPROVED BY DSA BEFORE PROCEEDING WITH THE WORK.
12. DSA IS NOT SUBJECT TO ARBITRATION.
1. ITEMS OF A CIVIL, LANDSCAPE, STRUCTURAL, MECHANICAL, OR ELECTRICAL NATURE MAY NOT APPEAR ON THE ARCHITECTURAL DRAWINGS. SEE APPROPRIATE DRAWINGS FOR THESE ITEMS.
2. DIVISION OF THE STATE ARCHITECT (DSA) APPROVAL OF THIS APPLICATION DOES NOT INCLUDE FUTURE OR N.I.C. ITEMS.
3. ALL DEFERRED APPROVAL ITEMS SHALL BE SUBMITTED TO THE ARCHITECT AND THE APPROPRIATE CONSULTING ENGINEER FOR REVIEW & APPROVAL PRIOR TO SUBMITTING TO DSA FOR CHECKING & APPROVAL.
4. THE FIRE SUPPRESSION SYSTEM, I.E. AUTOMATIC SPRINKLERS, HOOD-DUCT SYSTEM, WET STANDPIPES, AND HYDRANTS SHALL NOT BE INSTALLED UNTIL SHOP DRAWINGS HAVE BEEN APPROVED BY THE FIRE & LIFE SAFETY SECTION AT DSA.
5. THE FIRE PROTECTION SIGNALING SYSTEM SHALL NOT BE INSTALLED UNTIL SHOP DRAWINGS, INCLUDING FIRE MARSHAL LISTING NUMBER FOR EACH COMPONENT OF THE SYSTEM, HAS BEEN SUBMITTED AND APPROVED BY THE STATE FIRE MARSHAL AT DSA.
6. FOOD HANDLING FACILITIES SHALL COMPLY WITH ALL LOCAL HEALTH DEPARTMENT REQUIREMENTS & CALIFORNIA UNIFORM RETAIL FOOD FACILITIES LAW.
7. PRIOR TO BIDDING, THE GENERAL CONTRACTOR SHALL VISIT & INSPECT THE SITE TO FAMILIARIZE THEMSELVES WITH THE EXISTING CONDITIONS AFFECTING THE NEW WORK. THE GENERAL CONTRACTOR SHALL NOT DISPUTE, COMPLAIN, OR ASSERT THAT THERE IS ANY MISUNDERSTANDING IN REGARDS TO LOCATION, EXTENT, NATURE, OR AMOUNT OF WORK TO BE PERFORMED UNDER THIS CONTRACT DUE TO THE CONTRACTOR'S FAILURE TO INSPECT THE SITE AND/OR FAILURE TO INSPECT THE CONTRACT DOCUMENTS.
8. THE GENERAL CONTRACTOR & SUBCONTRACTORS ARE RESPONSIBLE FOR LOCATING & VERIFYING ALL EXISTING UNDERGROUND UTILITIES IN ALL AREAS OF THE NEW WORK PRIOR TO COMMENCEMENT OF EXCAVATION. EXISTING UTILITIES SHOWN ON THE DRAWINGS ARE APPROXIMATE ROUTING LOCATIONS AS BEST DETERMINED FROM EXISTING DRAWINGS & BY THE SCHOOL DISTRICT, BUT SHOULD NOT BE CONSTRUED TO REPRESENT ALL EXISTING UTILITIES.
9. ANY ALTERATIONS OF EXISTING FACILITIES TO ACCOMMODATE THE INSTALLATION OF NEW WORK SHALL BE REVIEWED BY THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK.
10. ALL EXISTING FINISHES OR MATERIALS DAMAGED OR DEMOLISHED DUE TO NEW CONSTRUCTION SHALL BE RESTORED TO THEIR ORIGINAL STATE OR REPLACED WITH NEW MATERIALS FINISHED TO MATCH EXISTING.
11. CONTRACTOR SHALL COORDINATE ALL WORK TO AVOID DISRUPTION OF STUDENTS OR TEACHERS DURING SCHOOL HOURS. ANY DISRUPTION OF POWER, TELEPHONE, OR HVAC SYSTEMS MUST BE COORDINATED AND APPROVED BY THE DISTRICT REPRESENTATIVE PRIOR TO ANY WORK COMMENCING.
12. COMPLIANCE WITH CFC CHAPTER 33 (FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION) AND CBC CHAPTER 33 (SAFEGUARDS DURING CONSTRUCTION) WILL BE ENFORCED.
1. NONE
PARTIAL LIST OF APPLICABLE STANDARDS (AS REFERENCED IN 2016 CBC - CHAPTER 35 & CFC):
ADA STANDARDS FOR ACCESSIBLE DESIGN (APPENDIX A OF 28 CFR PART 36) 2010 EDITION
ASME 17.1 2016 SAFETY CODE FOR ELEVATORS AND ESCALATORS (ASME A17.1-2016/CSA B44-16) 2016 EDITION
NFPA 13 STANDARD FOR INSTALLATION OF SPRINKLER SYSTEMS 2016 EDITION
NFPA 14 STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEMS 2016 EDITION
NFPA 17 STANDARD FOR DRY CHEMICAL EXTINGUISHING SYSTEMS 2017 EDITION
NFPA 17-A STANDARD FOR WET CHEMICAL EXTINGUISHING SYSTEMS 2017 EDITION
NFPA 20 STANDARD FOR THE INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION 2016 EDITION
NFPA 22 STANDARD FOR WATER TANKS FOR PRIVATE FIRE PROTECTION 2013 EDITION
NFPA 24 STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES 2016 EDITION
NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE 2016 EDITION
NFPA 80 STANDARD FOR FIRE DOOR AND OTHER OPENING PROTECTIVES 2016 EDITION
NFPA 110 STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS 2016 EDITION
NFPA 253 STANDARD METHOD OF TEST FOR CRITICAL RADIANT FLUX OF 2015 EDITIONFLOOR COVERING SYSTEMS USING A RADIANT HEAT ENERGY SOURCE
NFPA 2001 STANDARD ON CLEAN AGENT FIRE EXTINGUISHER SYSTEMS 2015 EDITION
ICC 300 BLEACHERS, FOLDING AND TELESCOPIC SEATING AND GRANDSTANDS 2012 EDITION
LOCATION MAP
BUILDING KEY
AREA OF WORK
CLASS
GYM
CAFETERIA
ADMIN
SCIENCE
CLASS
CLASS
CLASS CLASS
CULINARY ARTS
N
SHEET #
STATE
REVISIONS
MILESTONES
SHEET
PROJECT
CONSULTANT
STAMP
DATE
JOB #
These drawings, and/or specifications, and/or calculations for the items listed above have been prepared by other design professionals or consultants who are licensed and/or authorized to prepare such drawings in this state. It has been examined by me for:
1. design intent and appears to meet the appropriate requirements of Title 24,California Code of Regulations and the project specifications prepared by me.
2. coordination with my plans and specifications and is acceptable forincorporation into the construction of this project.
The Statement of General Conformance "shall not be construed as relieving me of my rights, duties, and responsibilities under Sections 17302 and 81138 of the Education Code and Sections 4-336, 4-341 and 4-344" of Title 24, Part 1. (Title 24, Part 1, Section 4-317(b))
ARCHITECT - DATE -
CALIFORNIA LICENSE NUMBER EXPIRATION DATE
*
w w w . a e d i s a r c h i t e c t s . c o m
387 S. 1st Street, Suite 300
S a n J o s e , C A 9 5 1 1 3
t e l : ( 4 0 8 ) - 3 0 0 - 5 1 6 0
f a x : ( 4 0 8 ) - 3 0 0 - 5 1 2 1
aedisarchitects
3/7
/2019
2:3
4:1
7 P
MC
:\U
sers
\kbaile
y\D
ocum
ents
\2018
037
- C
onle
y C
ara
ba
llo H
S C
ulin
ary
Art
s M
od
ern
- (
201
8 v
ers
ion
)_kbaile
yK
KP
JP
.rvt
T1
TITLE SHEET
NEW HAVEN UNIFIEDSCHOOL DISTRICT
CONLEYCARABALLO HSCULINARY ARTSMODERNIZATION
11/13/18
2018037JOE VELA
NEW HAVEN UNIFIED SCHOOL DISTRICT
34200 ALVARADO-NILES ROAD, UNION CITY, CA 94587
CONSTRUCTION DOCUMENTS
CONLEY CARABALLO HS CULINARYARTS MODERNIZATION
T1 TITLE SHEET
A1.01 SITE PLAN
A2.01 DEMOLITION FLOOR PLAN
A3.01 NEW FLOOR PLAN, REFLECTED CEILING PLAN, INTERIOR ELEVATIONS, & DETAILS
& AND@ ATA.B. ANCHOR BOLTABV. ABOVEA.C. ASPHALTIC CONCRETEACT ACOUSTIC TILEADJ. ADJUSTABLEA.F.F. ABOVE FINISHED FLOORALUM. ALUMINUMA.P. ACCESS PANELAPPROX. APPROXIMATELYARCH. ARCHITECT
BD. BOARDBLDG. BUILDINGBLKG. BLOCKINGBM BEAMB.M. BENCH MARKBOT. BOTTOMBTWN BETWEENB.W. BOTH WAYS
CAB. CABINETC.B. CATCH BASINC.C or O.C. CENTER TO CENTERCEM. CEMENTCER. TILE CERAMIC TILEC.G. CORNER GUARDC.I. CAST IRONC.J. CONTROL JOINTCLG. CEILINGCLKG. CAULKINGCLR. CLEARCMU CONCRETE MASONRY UNITCNTR. COUNTERC.O. CLEANOUTCOL. COLUMNCONC. CONCRETECONST. CONSTRUCTIONCONT. CONTINUOUSCONTR. CONTRACTORC.P. CONCRETE PIPECTR. CENTERCTSK. COUNTER SUNKC.W. COLD WATER
D.A. DISABLED ACCESSDBL DOUBLED.F. DRINKING FOUNTAIND.FIR DOUGLAS FIRDTL. DETAILDIA. or Ø DIAMETERDIM. DIMENSIONDISP. DISPOSALDN DOWNDO DITTODR. DOORDS. DOWNSPOUTDWG. DRAWING
(E) EXISTINGE. EASTEA. EACHE.J. EXPANSION JOINTELEC. ELECTRIC or ELECTRICALEL. ELEVATIONELEV. ELEVATORENCL. ENCLOSE and/or ENCLOSUREEQ. EQUALEQUIP. EQUIPMENTE.W. EACH WAYE.W.C. ELECTRIC WATER COOLEREX. EXPANSIONEXP. EXPOSEDEXT. EXTERIOR
F.A. FIRE ALARMF.D. FLOOR DRAINFDN. FOUNDATIONF.E. FIRE EXTINGUISHERF.E.C. FIRE EXTINGUISHER CABINETF.H. FIRE HYDRANTF.H.C. FIRE HOSE CABINETF.H.S.M.S. FLAT HEAD SHEET METAL SCREWF.H.W.S. FLAT HEAD WOOD SCREWFIN. FINISHFL. or FLR. FLOORF.O.C. FACE OF CONCRETEF.O.F. FACE OF FINISHF.O.M. FACE OF MASONRYF.O.S. FACE OF STUDF.R.P. FIBERGLASS REINFORCED PLASTIC PANELF.S. FINISH SLABFT. FOOT OR FEETFTG. FOOTINGFURR. FURRING
GA. GAUGEGALV. GALVANIZEDG.B. GRAB BARG.I. GALVANIZED IRONGL. GLASSGLU-LAM GLUE-LAMINATEDGND. GROUNDGR. GRADEGYP. GYPSUM
H.B. HOSE BIBBH.C. HOLLOW COREHDWD. HARDWOODHDWR. HARDWAREH.M. HOLLOW METALHORIZ. HORIZONTALHR. HOURHT. HEIGHT
I.D. INSIDE DIAMETERINSUL. INSULATIONINT. INTERIORINV. INVERT
JAN. JANITORJT JOINT
K.D. KILN DRIED
ABBREVIATIONS BOARD OF TRUSTEESLAB. LABORATORYLAM. LAMINATELAV. LAVATORYLKR. LOCKERLT. LIGHT
MAX. MAXIMUMM.B. MACHINE BOLTMECH. MECHANICALMFR. MANUFACTURERM.H. MANHOLEMIN. MINIMUMMIR. MIRRORMISC. MISCELLANEOUSM.O. MASONRY OPENINGM.S. MACHINE SCREWMTD. MOUNTEDMTL. METALMUL. MULLION
(N) NEWN. NORTHN.I.C. NOT IN CONTRACTNO. or # NUMBERNOM. NOMINALN.T.S. NOT TO SCALE
OBS. OBSCUREO.C. ON CENTEROCC. OCCUPANT(CY)O.D. OVERFLOW DRAIN and/or OUTSIDE DIAMETERO.F.O.S. OUTSIDE FACE OF STUDO.F.C.I. OWNER FURNISHED and CONTRACTOR INSTALLEDO.H. OPPOSITE HANDOPNG. OPENINGOPP. OPPOSITE
P.A.F. POWDER ACTUATED FASTENERPL PLATEP.L. PROPERTY LINEP. LAM PLASTIC LAMINATEPLAS. PLASTERPLYWD. PLYWOODPR. PAIRPTD. PAINTEDPTN. PARTITION
Q.T. QUARRY TILE
R. or RAD. RADIUSR.C.P. REINFORCED CONCRETE PIPER.D. ROOF DRAINR.E. RIM ELEVATIONREF. REFERENCEREINF. REINFORCINGREQ'D REQUIREDR.H.M.S. ROUND HEAD METAL SCREWR.H.W.S. ROUND HEAD WOOD SCREWRM. ROOMR.O. ROUGH OPENINGRWD. REDWOODR.W.L. RAIN WATER LEADER
S SOUTHS.A.D. SEE ARCHITECTURAL DRAWINGSS.C. SOLID CORES.C.D. SEE CIVIL DRAWINGSSCHED. SCHEDULES.E.D. SEE ELECTRICAL DRAWINGSS.F. SQUARE FEETSHEATH. SHEATHINGSHT. SHEETSIM. SIMILARS.L.D. SEE LANDSCAPE DRAWINGSS.M. SHEET METALS.M.D. SEE MECHANICAL DRAWINGSS.M.S. SHEET METAL SCREWS.O.V. SHUT OFF VALVES.P.D. SEE PLUMBING DRAWINGSSPEC. SPECIFICATIONSSQ. or Ø SQUARES.S. STAINLESS STEELS.S.D. SEE STRUCTURAL DRAWINGSSTAG. STAGGEREDSTD. STANDARDSTL. STEELSTOR. STORAGESTRUCT. STRUCTURALS.T.S.M.S. SELF TAPPING SHEET METAL SCREWSUSP. SUSPENDED
T.& G. TONGUE & GROOVETEL. TELEPHONETERR. TERRAZZOTHRES. THRESHOLDT.J. TOOLED JOINTT.O.B. TOP OF BEAMT.O.C. TOP OF CURB or CONCRETET.O.S. TOP OF STEEL or SLABT.O.W. TOP OF WALLTYP. TYPICAL
U.O.N. UNLESS OTHERWISE NOTED
VERT. VERTICALV.C.P. VITRIFIED CLAY PIPEV.C.T. VINYL COMPOSITION TILEV.G. VERTICAL GRAINV.I.F. VERIFY IN FIELDV.T.R. VENT THROUGH ROOFV.W.C. VINYL WALL COVERING
W WESTW/ WITHW.C. WATER CLOSETWD. WOODW.H. WATER HEATERW/O WITHOUTW.O. WHERE OCCURSWP. WATERPROOF / WEATHERPROOFW. PT. WORKING POINTW.R. WATER RESISTANTWT. WEIGHT
APPLICABLE CODES
REFERENCE STANDARDS
ADMINISTRATIVE REQUIREMENTS
SYMBOL LEGEND
GENERAL NOTES
DEFERRED APPROVAL ITEMS
SCOPE OF WORK
DRAWING INDEX
ARCHITECTURAL
LINDA CANLAS (PRESIDENT)SARABJIT CHEEMA (CLERK)LANCE NISHIHIRA (MEMBER)SHARAN KAUR (MEMBER)JEFF WANG (MEMBER)
DISTRICT SUPERINTENDANTDR. ARLANDO SMITH
• CONVERSION OF (2) EXISTING RESTROOMS TO A SCULLERY• REPLACEMENT OF (E) WATER HEATER• INSTALLATION OF CABINETRY SUPPORT• REMOVAL OF EXISTING PLAY STRUCTURE
No. Description Date
RECORD DRAWINGS - FOR REFERENCE ONLY
CLASSROOM WING 1A SCIENCE WING CLASSROOM WING 2 PLUMBING FLOOR PLAN CLASSROOM WING 2 CHILD CARE BUILDING SCIENCE WING POWER PLANSPANEL SCHEDULES
P2.2E3.2E6.1
ALTERNATIVE EDUCATION CENTER AT EL RANCHO VERDE SITE, 2005
CONVERSION OF DAY CARE BUILDING TO CULINARY ARTS CLASSROOM AT CONLEY CARABALLO HIGH SCHOOL, 2011
NEW FLOOR PLANPLUMBING AND HVAC FLOOR PLANS
A03.01P02.01
03/07/2018
PROPERTY LINE
EXISTING TOILET ROOMS. REFER TO NOTES FOR ADDITIONAL INFORMATION.
(E) FENCING
EXISTING CONSTRUCTION TO REMAIN
FIRE DEPARTMENT ACCESSFIRE DEPARTMENT ACCESS IS 20'-0" WIDE AND RATED FOR 96,000 LBS.
DA D.A. PATH OF TRAVEL AS INDICATED ON PLAN IS A BARRIER FREE ACCESS WITHOUT ANY ABRUPT LEVEL CHANGES EXCEEDING 1/2" BEVELED AT 1:2 MAXIMUM SLOPE OR VERTICAL LEVEL CHANGES NOT EXCEEDING 1/4" MAXIMUM AND AT LEAST 48" WIDE. SURFACE IS SLIP RESISTANT, STABLE, FIRM, AND SMOOTH. CROSS SLOPE DOES NOT EXCEED 2% AND SLOPE IN THE DIRECTION OF TRAVEL IS LESS THAN 5% UNLESS OTHERWISE INDICATED. D.A. PATH OF TRAVEL SHALL BE MAINTAINED FREE OF OVERHANGING OBSTRUCTIONS TO 80" MINIMUM HEIGHT AND PROTRUDING OBJECTS GREATER THAN 4" PROJECTION FROM WALL ABOVE 27" AND BELOW 80". ARCHITECT SHALL VERIFY THAT THERE ARE NO BARRIERS IN THE PATH OF TRAVEL.
D.A. PATH OF TRAVEL
LOCATION OF NEW FIRE HYDRANT, SEE CIVIL DRAWINGS FOR ADDITIONAL INFORMATION
(N) F.H.
EXISTING FIRE HYDRANT
(E) F.H.
AREA OF WORK
ASSUMED PROPERTY LINE
GRAPHIC KEY
(E) CLASSROOMS
TREVOR AVENUE
(E) PARKING LOT
BLAN
CHE S
TREET
(E) CLASSROOMS (E) CLASSROOMS
(E) CLASSROOMS
(E) CLASSROOMS
(E) GYM
(E) CAFETERIA
(E) ADMIN
(E) PLAYFIELD
(E) SCIENCE
CLASSROOMS
AM
ELIA
AVENUE
DA
DA
DA
DA
DA
DADA
A3.011
A2.011
COLLAR TIES, TYP.
TOP RAIL, TYP.
BOTTOM RAIL, TYP.
CHAIN LINK FENCE, PANEL SYSTEM.
CONCRETE BASE.
6' -
0"
SHEET #
STATE
REVISIONS
MILESTONES
SHEET
PROJECT
CONSULTANT
STAMP
DATE
JOB #
w w w . a e d i s a r c h i t e c t s . c o m
387 S. 1st Street, Suite 300
S a n J o s e , C A 9 5 1 1 3
t e l : ( 4 0 8 ) - 3 0 0 - 5 1 6 0
f a x : ( 4 0 8 ) - 3 0 0 - 5 1 2 1
aedisarchitects
03/07/2018
3/7
/2019
2:3
4:1
3 P
MC
:\U
sers
\kbaile
y\D
ocum
ents
\2018
037
- C
onle
y C
ara
ba
llo H
S C
ulin
ary
Art
s M
od
ern
- (
201
8 v
ers
ion
)_kbaile
yK
KP
JP
.rvt
A1.01
SITE PLAN
NEW HAVEN UNIFIEDSCHOOL DISTRICT
CONLEYCARABALLO HSCULINARY ARTSMODERNIZATION
2018037
NEW SITE PLAN KEYNOTES
N
GENERAL SHEET NOTES
A CONTRACTOR TO VERIFY THAT ALL BARRIERS TO THE SPACE IN THE PATH OF TRAVEL HAVE BEENREMOVED OR WILL BE REMOVED UNDER THIS PROJECT AND PATH OF TRAVEL COMPLIES WITHCBC 11B-206.
B CONTRACTOR SHALL MAINTAIN FIRE LANE ACCESS THROUGHOUT PROJECT.
C DO NOT INTERRUPT EXISTING UTILITY SERVICES SERVING OCCUPIED OR USED FACILITIES,EXCEPT WHEN AUTHORIZED IN WRITING BY AND COORDINATED WITH THE OWNER.
D PROTECT EXISTING & NEW STRUCTURES, UTILITIES, SIDEWALKS, PAVEMENTS, TREES ANDSHRUBS FROM DAMAGE DURING CONSTRUCTION.
E THE POT IDENTIFIED IN THESE CONSTRUCTION DOCUMENTS IS COMPLIANT WITH THE CURRENTAPPLICABLE CALIFORNIA BUILDING CODE ACCESSIBILITY PROVISIONS FOR PATH OF TRAVELREQUIREMENTS FOR ALTERATIONS, ADDITIONS AND STRUCTURAL REPAIRS. AS PART OF THEDESIGN OF THIS PROJECT, THE POT WAS EXAMINED AND ANY ELEMENTS, COMPONENTS ORPORTIONS OF THE POT THAT WERE DETERMINED TO BE NONCOMPLIANT 1) HAVE BEENIDENTIFIED AND 2) THE CORRECTIVE WORK NECESSARY TO BRING THEM INTO COMPLIANCE HASBEEN INCLUDED WITHIN THE SCOPE OF THE PROJECTS WORK THROUGH DETAILS, DRAWINGSAND SPECIFICATIONS INCORPORATED INTO THESE CONSTRUCTION DOCUMENTS. ANYNONCOMPLIANT ELEMENTS, COMPONENTS OR PORTIONS OF THE POT THAT WILL NOT BECORRECTED BY THIS PROJECT BASED ON VALUATION THRESHOLDS OR LIMITATIONS OR AFINDING OF UNREASONABLE HARDSHIP ARE SO INDICATED IN THESE CONSTRUCTIONDOCUMENTS. DURING CONSTRUCTION IF POT ITEMS WITHIN THE SCOPE OF THE PROJECTREPRESENTED AS CODE COMPLIANT ARE FOUND TO BE NONCONFORMING BEYOND REASONABLECONSTRUCTION TOLERANCES, THEY SHALL BE BROUGHT INTO COMPLIANCE.
SCALE: 1" = 20'-0"2 CONLEY CARABALLO SITE PLAN
SCALE: 1/2" = 1'-0"1 REQ'D TEMPORARY CONSTRUCTION FENCE
No. Description Date
DW
REF.
DW
EXISTING WALL TO REMAIN.
EXISTING WALL TO BE DEMOLISHED.
WALL TYPES:
GRAPHIC KEY
(E) HOME ECONOMICS
1
(E) UTILITY
2
(E) ROOM
3
(E) RESTROOM
5
(E) RESTROOM
4
16' - 10" V.I.F.
32
' - 6
" V
.I.F
.
1
2
3
45
TYP.
6
7
8
9
9 10
BUILDING KEY
CLASS.
GYM
CAFETERIA
ADMIN
SCIENCE
CLASS.
CLASS.
CLASS. CLASS.
CULINARY ARTS
N
SHEET #
STATE
REVISIONS
MILESTONES
SHEET
PROJECT
CONSULTANT
STAMP
DATE
JOB #
w w w . a e d i s a r c h i t e c t s . c o m
387 S. 1st Street, Suite 300
S a n J o s e , C A 9 5 1 1 3
t e l : ( 4 0 8 ) - 3 0 0 - 5 1 6 0
f a x : ( 4 0 8 ) - 3 0 0 - 5 1 2 1
aedisarchitects
03/07/2018
3/7
/2019
2:3
4:1
3 P
MC
:\U
sers
\kbaile
y\D
ocum
ents
\2018
037
- C
onle
y C
ara
ba
llo H
S C
ulin
ary
Art
s M
od
ern
- (
201
8 v
ers
ion
)_kbaile
yK
KP
JP
.rvt
A2.01
DEMOLITIONFLOOR PLAN
NEW HAVEN UNIFIEDSCHOOL DISTRICT
CONLEYCARABALLO HSCULINARY ARTSMODERNIZATION
2018037
DEMOLITION FLOOR PLAN KEYNOTES
N
GENERAL SHEET NOTES
A ROOM NAMES OR NUMBERS MAY NOT BE CONSISTENT BETWEEN DEMOLITION AND NEW FLOORPLANS.
B VERIFY LIMITS OF DEMOLITION WITH SCOPE OF NEW WORK PRIOR TO COMMENCING WORK.
C ALL ITEMS SHOWN DASHED ARE TO BE DEMOLISHED UNLESS OTHERWISE NOTED ON PLANS.
D REMOVE ALL MISCELLANEOUS TRIM, CASEWORK, EQUIPMENT, CONDUIT, BASES, AND OTHERSURFACE MOUNTED ITEMS WHETHER SHOWN OR NOT ON PARTITIONS TO BE DEMOLISHED.REMOVE AND CAP ALL OUTLETS, SWITCHES, WIRES, THERMOSTATS, ETC. TO THEIR SOURCE ASREQUIRED.
E ALL FLOORING MATERIALS ARE TO BE REMOVED TO TOP OF EXISTING SLAB BY MECHANICALMEANS U.O.N. TOP OF EXISTING SLAB TO BE LEFT SMOOTH, CLEAN, AND FREE OF ALL ADHESIVEAND READY FOR INSTALLATION OF NEW FLOORING.
F ALL ITEMS TO BE REMOVED SHALL BE DISPOSED OF PER PROJECT MANUAL REQUIREMENTS.
1 REMOVE (E) DOOR AND FRAME AT (E) RESTROOM.
2 REMOVE (E) HOT WATER HEATER.
3 ADD. ALTERNATE #1: REMOVE (E) PLAY STRUCTURE AND PLAY SURFACE. SEE NEW FLOOR PLAN.
4 (E) ASPHALT AND RAISED BED PLANTERS TO REMAIN.
5 (E) CONCRETE WALKWAYS TO REMAIN.
6 REMOVE AND REPLACE (E) DOOR HEADERS AND ASSOCIATED FRAMING AS REQUIRED, SEE NEWFLOOR PLAN FOR MORE INFORMATION.
7 REMOVE (E) DRAWERS AND GLIDES FOR INSTALLATION OF COUNTERTOP SUPPORT, SEE NEW FLOORPLAN FOR MORE INFORMATION.
8 ROUGHEN TILE FINISH FOR ADHESION OF FINISH PANELS, TYPICAL.
9 REMOVE (E) PLUMBING CAP. REMOVE (E) WALL FINISH AS REQUIRED TO RE-CAP BETWEEN WALLFRAMING.
10 SALVAGE AND REINSTALL PLUMBING ACCESS PANEL.
SCALE: 1/4" = 1'-0"1 CULINARY ARTS - DEMO FLOOR PLAN
No. Description Date
DW
REF.D
W
EXISTING WALL TO REMAIN.
WALL TYPES:
GRAPHIC KEY
EXISTING WALL ABOVE TO REMAIN.
(E) HOME ECONOMICS
1
(E) UTILITY
2
SCULLERY
4
(E) ROOM
3
16' - 10" V.I.F.
32
' - 6
" V
.I.F
.
A3.01
3
1
2
3
4
5
6
7
8
12
6' -
2"
7' -
9"
V.I
.F.
11' - 3 1/4" V.I.F.
15
15
VERIFY W/ OWNER
+/- 4' - 0"
TYP.13
BUILDING KEY
CLASS.
GYM
CAFETERIA
ADMIN
SCIENCE
CLASS.
CLASS.
CLASS. CLASS.
CULINARY ARTS
N
8' - 0"
(E)
(E) HOME ECONOMICS
1
SCULLERY
4
10
11
10
(E)
(E)
(E) UTILITY
2
(E) ROOM
3
OPEN
B-1
1
TYP. @ ALL SCULLERY WALLS
TYP. 13
4' -
0"
8
14
9
(E)
8' -
0"
V.I
.F.
2
SCULLERY WALLS
@ ALLTYP.16 3
4
NOTES :1. CONTRACTOR SHALL VERIFY EXACT DIMENSIONS PRIOR TO INSTALLATION, TYP.2. GRIND SMOOTH ANY SHARP OR ABRASIVE ELEMENTS UNDER COUNTER, TYP.
SUPPORT SECTION
(E) COUNTERTOP & BACKSPLASH.
(E) WALL & FINISH
(E) FLOOR FINISH
(1) 0.145" x 1-1/4" POWDER DRIVEN PIN ANCHOR EACH ANGLE.
(3) 1-1/4" x 1-1/4" x 1-1/4" 16 GA. ANGLES EACH BRACE - TWO (2) ANGLES ON ONE
SIDE AND ONE (1) ANGLE ON THE OPPOSITE SIDE, PAINT TYP.
(1) #8 x 3/4" F.H.W.S. THROUGH PRE-DRILLED HOLE AT EACH ANGLE.
3/4" PRE-FINISHED P-LAM PLYWOOD TO MATCH (E) CABINETRY.
(E) COUNTER SUPPORT
2" x 2" x 2" 16 GA. ANGLES WITH (1) #8 x 3/4" F.H.W.S. EACH LEG OF
ANGLE - TWO (2) ANGLES ON ONE SIDE AND ONE (1) ANGLE ON THE
OPPOSITE SIDE, PAINT TYP.
(E) 2' - 6" V.I.F.
EQ. EQ. EQ. EQ. 5"
14"
6"
EX
IST
ING
(E) TILE TO REMAIN
WOOD SHIM
CASED OPENING ABOVE
STAINLESS STEEL CORNER GUARD FROM +0'-0" TO +
4'-0" A.F.F., TYP.
4"
(E) WALL & (E) FRAMING
TO REMAIN
STAINLESS STEEL WALL PANEL
CONT. 1X WOOD TRIM. PAINTED,
TYP.
JAMB SECTIONHEADER ELEVATION
REMOVE (E) HEADER & REPLACE WITH 6x10, V.I.F.
(E) STUDS. TRIM AS REQ'D FOR HEADER INSTALLATION
(E) JAMB FRAMING TO REMAIN.
(4) 16D AT EA. SIDE.
(2) A35 WITH FASTENERS AT EA. SIDE.
NOTES:1. FINISHES HIDDEN FOR CLARITY. 2. REMOVE ADJACENT FINISHES AS REQUIRED FOR INSTALLATION. PATCH AND FINISH TO MATCH ADJACENT.
(E) WALL
O.F.C.I. 30 GAL. ELECTRIC HOT WATER HEATER.
2" WIDE x 16 GA. GALVANIZED SHEET METAL SEISMIC STRAPS.
ATTACH TO SHEET METAL BRACKET WITH 3/8" DIA.
MACHINE BOLT, TYPICAL OF (2). MOUNT (1) WITHIN THE UPPER
1/3 OF UNIT AND (1) WITHIN THE LOWER 1/3 OF UNIT.
SECURE BRACKET TO WALL WITH 2" DIA. x 2 1/2" LONG LAG BOLTS
(E) FLOOR SYSTEM
20" DIA.
PROVIDE GRAINGER WATER HEATER STAND
MODEL #40-S-24-U, ANCHORED TO FLOOR
4X BLOCKING SECURED TO (E) STUDS @ EACH END WITH "SIMPSON" A35 FRAMING ANCHORS TOP & BOTTOM.
REMOVE (E) GYP. BOARD WALL FINISH FOR CONNECTION & RELOCATION OF (E) UTILITIES. PATCH, FINISH, AND PAINT WALL TO MATCH (E) ADJACENT SURFACES.
2"x2"x1/4" ANGLE, LENGTH AS REQUIRED TO FASTEN TO (3) STUDS MINIMUM.
10 GA. SHEET METAL FORMED BRACKET, ATTACH BRACKET
TO ANGLE WITH 3/8" DIA. MACHINE BOLTS, MINIMUM (4)
EQUALLY SPACED.
ALUMINUM EDGE TRIM
3/8
"
PANEL
ADHESIVE
SEALANT 1/4"
ALUMINUM EDGE TRIM
3/8" PANEL
ADHESIVESEALANT
1/4
"
TOP EDGE
VERTICAL EDGE
SUBWALL
SUBWALL
ALUMINUM OUTSIDE
CORNER TRIM
7/16"
PANEL
ADHESIVE
SEALANT
7/1
6"
OUTSIDE CORNER
SUBWALL ALUMINUM INSIDE CORNER TRIM PANEL
ADHESIVE
SEALANT
INSIDE CORNER
SUBWALL
3/8"
ALUMINUM EDGE TRIM
PANEL
ADHESIVE
SEALANT
BOTTOM EDGE
SUBWALL
1/4"
3/8
"
ALUMINUM DIVISION PANEL
ADHESIVE
SEALANT
VERTICAL JOINT
SUBWALL
SHEET #
STATE
REVISIONS
MILESTONES
SHEET
PROJECT
CONSULTANT
STAMP
DATE
JOB #
w w w . a e d i s a r c h i t e c t s . c o m
387 S. 1st Street, Suite 300
S a n J o s e , C A 9 5 1 1 3
t e l : ( 4 0 8 ) - 3 0 0 - 5 1 6 0
f a x : ( 4 0 8 ) - 3 0 0 - 5 1 2 1
aedisarchitects
03/07/2018
3/7
/2019
2:3
4:1
6 P
MC
:\U
sers
\kbaile
y\D
ocum
ents
\2018
037
- C
onle
y C
ara
ba
llo H
S C
ulin
ary
Art
s M
od
ern
- (
201
8 v
ers
ion
)_kbaile
yK
KP
JP
.rvt
A3.01
NEW FLOORPLAN,REFLECTEDCEILING PLAN,INTERIORELEVATIONS, &DETAILS
NEW HAVEN UNIFIEDSCHOOL DISTRICT
CONLEYCARABALLO HSCULINARY ARTSMODERNIZATION
2018037
NEW FLOOR PLAN KEYNOTES
GENERAL SHEET NOTES
A ROOM NAMES OR NUMBERS MAY NOT BE CONSISTENT BETWEEN DEMOLITION AND NEW FLOORPLANS.
B DIMENSIONS FOR EXISTING BUILDINGS ARE APPROXIMATE. CONTRACTOR TO FIELD VERIFYPRIOR TO START OF CONSTRUCTION.
C CONTRACTOR TO PROVIDE ALL APPROPRIATE CONNECTIONS, MOUNTINGS, HARDWARE, PIPING,FITTINGS, AND/OR MATERIALS FOR COMPLETE INSTALLATIONS AND FUNCTIONAL OPERATIONS.
D ON EXISTING WALLS TO RECEIVE STAINLESS STEEL PANELING, SALVAGE AND REINSTALL ALLACCESS PANELS, SWITCHES, FIRE ALARMS, U.O.N.
1 CASED OPENING HEADER, SEE DETAIL 5/A3.01. REMOVE WALL FINISH AS REQUIRED FOR INSTALLATION.PATCH, FINISH, AND PAINT TO MATCH (E) ADJACENT.
2 THREE COMPARTMENT SINK, ADVANCE TABCO #94-23-60, AND FAUCET AND NOZZLE, O.F.C.I. PROVIDEAND EXTEND CONNECTIONS TO ALL (E) UTILITIES.
3 JACKSON TEMPSTAR VER VENTLESS DISHWASHER AND TWO DRAIN TABLES, O.F.C.I. PROVIDE ANDEXTEND CONNECTIONS TO ALL (E) UTILITIES. CONFIRM PLACEMENT WITH OWNER PRIOR TOINSTALLATION.
4 METRO #PR48X3 METROMAX I STATIONARY DRYING RACK, O.F.C.I.
5 BRADFORD WHITE #RE330S6 30 GAL. ELECTRIC HOT WATER HEATER FOR SINKS AND DISHWASHER,O.F.C.I. SEE DETAIL 6/A3.01. PROVIDE AND EXTEND CONNECTIONS TO ALL (E) UTILITIES.
6 PATCH (E) TERRACOLOR DEX-O-TEX EPOXY FLOORING WHERE WALL WAS REMOVED. PROVIDE COVEDBASE AND FLOORING TRANSITION TO MATCH ADJACENT. FINISH AND COLOR TO MATCH ADJACENTSUBMIT PRODUCT DATA FOR APPROVAL.
7 ADD. ALTERNATE #1: GRIND DOWN ALL CUT POSTS FROM REMOVED PLAY STRUCTURE PRIOR TOASPHALT INSTALLATION. PATCH HOLES IN ASPHALT WHERE PLAY STRUCTURE WAS REMOVED. PROVIDEASPHALT WHERE PLAY SURFACE WAS REMOVED, FOR A SMOOTH AND LEVEL SURFACE.
8 ALL (E) FIRE ALARM/SMOKE DETECTORS IN SCULLERY TO BE REPLACED WITH HEAT DETECTORS.
9 F.R.P. TO BE INSTALLED OVER (E) TILE WITH MANUFACTURER'S STANDARD TRIM AT ALL PANEL EDGES,PER DETAIL 7/A3.01. FULL HEIGHT AND FULL WALL EXTENTS. COLOR TO BE SELECTED FROMMANUFACTURER'S FULL LINE.
10 REPLACE (E) FANS WITH PANASONIC FV-30VQ3, OR APPROVED EQUAL QUIET FAN. FANS TO BE COMBINEDONTO (1) SWITCH. REPLACE SWITCH AND FACEPLATE AS REQUIRED.
11 PATCH (E) GYP. BOARD CEILING WHERE WALL WAS REMOVED. PREP AND PAINT (E) GYP. BOARD CEILINGTHROUGHOUT. KELLY MOORE OR SHERWIN WILLIAMS, GLOSS FINISH. COORDINATE COLOR SELECTIONWITH DISTRICT FROM MANUFACTURER'S FULL RANGE.
12 COUNTER SUPPORT, SEE DETAIL 4/A3.01.
13 STAINLESS STEEL CORNER GUARD FROM +0'-0" TO +4'-0" A.F.F., TYPICAL AT ALL SIDES. GRIND EDGESSMOOTH PRIOR TO INSTALLATION.
14 REPLACE OR SALVAGE AND REINSTALL (E) LIGHT SWITCH, AS REQUIRED.
15 CONNECT TO (E) UTILITIES. REFER TO RECORD DRAWINGS. REMOVE WALL FINISH AS REQUIRED FORINSTALLATION. PATCH WALLS WITH WATER RESISTANT PANELING TO BE FLUSH TO ADJACENT TILE PRIORTO F.R.P. INSTALLATION.
16 ROUGHEN TILE FINISH FOR ADHESION OF FINISH PANELS, TYPICAL.
SCALE: 1/4" = 1'-0"1 CULINARY ARTS - NEW FLOOR PLAN
N
SCALE: 1/4" = 1'-0"2 CULINARY ARTS - REFLECTED CEILING PLAN
NORTH EAST SOUTH WEST
SCALE: 1/4" = 1'-0"3 SCULLERY INTERIOR ELEVATIONS
SCALE: 1 1/2" = 1'-0"4 COUNTER SUPPORT DETAIL
SCALE: 3" = 1'-0"5 HEADER AND CASED OPENING
SCALE: 1" = 1'-0"6 HOT WATER HEATER ANCHORAGE DETAIL
SCALE: 3" = 1'-0"7 TYPICAL FRP TRIM & MOULDINGS
No. Description Date
REFERENCE DRAWING - FOR UTILITY REFERENCE ONLY
REFERENCE DRAWING - FOR UTILITY REFERENCE ONLY
REFERENCE DRAWING - FOR UTILITY REFERENCE ONLY
REFERENCE DRAWING - FOR UTILITY REFERENCE ONLY
REFERENCE DRAWING - FOR UTILITY REFERENCE ONLY