+ All Categories
Home > Documents > Connecting a Third Millenium TM4 reader to Net2 · The TM4 can be configured to read a variety of...

Connecting a Third Millenium TM4 reader to Net2 · The TM4 can be configured to read a variety of...

Date post: 12-Aug-2020
Category:
Upload: others
View: 8 times
Download: 0 times
Share this document with a friend
1
Connecting a Third Millenium TM4 reader to Net2 Overview 3rd Party Ensure any unused wires are safely terminated. ACU terminal +12V Red LED Amber LED Green LED Wiegand D0 Wiegand D1 NOT USED 0V Cable Pinout Terminal 1 Terminal 3 Terminal 2 Terminal 7 Terminal 5 - Terminal 4 - The TM4 can be configured to read a variety of different token types, and to output a variety of different data formats. The configuration performed during manufacturer, and the full part number of the unit will indicate the configuration type. If this is unknown, contact Third Millenium to confirm these details, as they will affect the how the Net2 software is configured. 1
Transcript
Page 1: Connecting a Third Millenium TM4 reader to Net2 · The TM4 can be configured to read a variety of different token types, and to output a variety of different data formats. The configuration

+44 (0)1273 811011

paxton.support

[email protected]

+44 (0)1273 811011

paxton.support

[email protected]

+1(800) 672-7298

usapaxton.support

[email protected]

+49 (0) 251 2080 6900

paxton.gmbh.support

[email protected]

+27 (0)21 4276691

paxton.support

[email protected]

+11 5715088198

paxton.soporte

[email protected]

+33 (0)157 329356

[email protected]

paxton.support

+31 (0)76 3333 999

paxton.benelux.support

[email protected]

+32 (0)78485147

paxton.benelux.support

[email protected]

8000 3570 3783

paxton.support

[email protected]

+1 (864) 751-3501

[email protected]

paxton.soporte

Connecting a Third Millenium TM4 reader to Net2Overview

3rd Party

Ensure any unused wires are safely terminated.

ACU terminal+12V

Red LED

Amber LED

Green LED

Wiegand D0

Wiegand D1

NOT USED

0V

Cable PinoutTerminal 1

Terminal 3

Terminal 2

Terminal 7

Terminal 5

-

Terminal 4

-

The TM4 can be configured to read a variety of different token types, and to output a variety of different data formats. The configuration performed during manufacturer, and the full part number of the unit will indicate the configuration type. If this is unknown, contact Third Millenium to confirm these details, as they will affect the how the Net2 software is configured.

1

Recommended